Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
PFI2020-00457
PFI_Utilities 15- UTILITY LOCATION CONFLICT Applied Notice Applicant must verify all existing utilities for both vertical elevation and horizontal location prior to start of work(pothole before digging if necessary). Should conflicts arise and redesign or relocation of facilities be necessary, it shall be done at the applicant's expense. Changes must be approved by the City in advance of work.Applicant shall coordinate the work with affected utility agencies. PFI_Utilities 16-TEMPORARY PATCH Applied Notice A temporary hard-surface patch shall be placed on trenches within roadways at the end of each work shift. Obtain advance approval of patching method. No trench shall be left at any time in an un-safe condition. Applicant is responsible for and is liable for hazards or damage resulting from the prosecution of the work. PFI_Utilities 17-REPAIR OF EXISTING FACILITIES Applied Notice Work under this permit shall include repair of existing facilities (roads, ditches, etc.)as may be necessary, as determined by the Inspector,to overcome deterioration or damage which occurred in conjunction with the work authorized by the permit. Corrective work shall be done at the applicant's expense. PFI_Utilities 19-PRECONSTRUCTION MEETING Applied Notice Before initiating any construction activity,the applicant shall coordinate with the City's inspector, <Insert Name>at<Insert Phone#>, to establish a preconstruction meeting. PFI_Utilities 20-NOTICE TO COMMENCE WORK Applied Notice The applicant shall notify the City's Inspector twenty-four(24) hours prior to commencing work, prior to any staged inspection, and after completing work covered by the permit. PFI_Utilities 21 -PERMIT/PLAN ON SITE Applied Notice A copy of the permit including a Certificate of Insurance,and all attachments, and a copy of the approved construction plan and all amendments shall be readily available at the work area. All work shall conform to the permit terms, conditions and provisions and to the City approved permit plans,and approved plan amendments and to the City's standards and specifications and to these General Conditions. Changes to any of these must be approved by the City, in advance of work performance. PFI_Utilities 22-DAILY INSPECTION REPORTS Applied Notice Applicant shall submit daily inspection reports, on a weekly basis,to the City's Inspector. PFI_Utilities 23-MONUMENT PROTECTION Applied Notice Existing monuments, property corners, and survey markers shall be protected. Replacement shall be at the permit holder's expense. PFI_Utilities 24-VALIDATION OF MATERIAL/CONSTRUCTION Applied Notice The City's Inspector may, at his discretion, require tests and or reports from the applicant to validate claims of material or construction adequacy/compliance. Such tests/reports shall be provided at the applicant's expense. PFI_Utilities 25-EMERGENCY CONTACTS Applied Notice Provide to the City inspector, in writing,the names and 24 hour emergency telephone number of two(2)persons who have authority to resolve problems,take corrective action and, in general,will be responsible in case of any emergency. The applicant shall notify the City Inspector, in writing,of any/all assignment changes. PFI_Utilities 26-RIGHT OF ENTRY/EASEMENTS Applied Notice Applicant to obtain proper right-of-entry and/or easements prior to starting work. Proof of right-of-entry or properly executed easements, shall be provided to the City. The City shall in no way be construed to be liable for the applicant's failure to obtain or provide for proof of right-of-entry or easements. PFI_Utilities 27- PRIVATE PROPERTY AGREEMENTS Applied Notice Provide the City a copy of an executed agreement[s]from the owner for each private property disturbed by construction activity. PFI_Utilities 28-AS-BUILT DRAWING Applied Notice 1,2,3,4,5 28-AS-BUILT DRAWING One as-built drawing showing all new public improvements, including any revision made to the previously approved construction plans and,also, any improvement which may impact an existing public system or facility, shall be provided to the City by a registered civil engineer along with an engineer's certification of installation compliance (Certificate of Compliance). 1,2,3,4,5 28-AS-BUILT DRAWING One as-built drawing showing all new public improvements, including any revision made to the previously approved construction plans and, also,any improvement which may impact an existing public system or facility, shall be provided to the City by a registered civil engineer along with an engineer's certification of installation compliance (Certificate of Compliance). One as-built drawing showing all new public improvements, including any revision made to the previously approved construction plans and,also, any improvement which may impact an existing public system or facility, shall be provided to the City by a registered civil engineer along with an engineer's certification of installation compliance(Certificate of Compliance). PFI_Utilities 31 -OTHER Applied Notice Other . RECEIVED City of Tigard NOV 2 3 2020 PFI#: .202D- c0 /C9.. ENGINEERING DEPARTMEN'ICITY OF TIGARD 1111 PLANNING/ENGINEERING TIGARD Public Facilities` Improvement (PFI) Permit PROJECT INFORMATION PGE Job # M2877626 TYPE OF WORK Project name: 8 TYPE 1—Franchise Utility Work Brief description of project: REPLACE PL3547 AND PL2481 perfomredbyNWN,PGE, or utility agency TOPS ARE ROTTEN OUT 0 TYPE 2—ROW Sidewalk/Driveway/Sewer Work performed for the purpose of: • Sidewalk installation or repair • Driveway approach installation and repair SITE INFORMATION • Sanitary sewer lateral installation and Location (address if available): 14350 Southwest 100th Avenue main line tap Sn� / . 0 TYPE 3—Ful Saalend Development Work .0 performed with land use approval which includes any of the following: • Subdivisions or Partitions APPLICANT INFORMATION • Street widening Name: PGE DENISE CHON FOR Linda Ott • Mainline installation for sanitary sewer, storm sewer, Tigard water, and Tigard Mailing address: 2213 SW 153rd Dr water service area city/state: Beaverton, OR Zip: 97003 ❑ TYPE 4-Small Cell Technology ❑ TYPE 5—Tigard Triangle Phone: C RE WCOO DINATI ON-W ESTERN tpgn.corn Email: Phone: NOTE: Type 1 and 2 applications may be Burl Hine emailed to rowpermits(rt7tigard-or.gov. Contact name: Phone: +1 (503) 463-6107 Email: • CONTRACTOR INFORMATION El Same as applicant Name: CCB Number: Mailing address: City/State: Zip: Phone: Email: ENGINEER INFORMATION Name: Mailing address: City/State: Zip: Phone: Email: ADDITIONAL INFORMATION Estimated value of work is required(if over$5,000):$ (within the public right-of-way) Is work related to a LAND USE DECISION? Oyes ❑r No Case number: City of Tigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • wwwtigard-or.gov • 503-718-2421 • Page 1 of 4 APPLICANTS NOTE: Person specified as"Applicant" shall be designated"Permittee"and shall provide financial assurance for work,if required by the city pursuant to TMC 15.04.140. * With the exception of a utility operating pursuant to a valid franchise or license with the City of Tigard,when the owner and the applicant are different people,the applicant must be the purchaser of record or a lessee in possession with written authorization from the owner 1 or an agent of the owner. The owner must sign this application in the space provided or submit a written authorization with this application. Franchised or Licensed Utilities are not required to obtain the owner's signature on the application. I, the applicant, certify that: • To the best of my knowledge,all the information provided within this application package is complete and accurate. • The above request does not violate any recorded deed restrictions that may be attached to or imposed upon the subject property. • If the application is granted, I will exercise the rights granted in accordance with the terms and subject to all the conditions and limitations of the approval. L`' a, Linda ott 11.20.20 Applicant's or authorized agent's signature Print name Date Property owner's signature (if required) Print name Date ��,,,,,,//,�...��� STAFF USE ONLY Case No: 1•�'Y�/2c .21 C2O±LIC i"ermit fee: 360,60 Received by: Date: 11/ Approved by: 7r'e i I�n?k yDate: ii/23/Z02.a Notified by: Date: 1/ `1") City of Tigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • wwwtigard-or.gov • 503-718-2421 • Page 2 of 4 DEVELOPMENT ENGINEERING FEES Public Facility Improvement(PFI)Permit: INITIAL PFI PERMIT FEE Part 1: Required submittal fee is 10%of the Net PH Permit Fee.See below for calculations.Minimum of$300. NET PFI PERMIT FEE Part 2: All non-water system improvements engineer's estimate X 7%(less the initial PFI Permit Fee). WATER LINE CONSTRUCTION FEE Part 3: All public water system improvements engineer's estimate X 12%. FOR STAFF USE ONLY FOR STAFF USE ONLY TYPE 4: SMALL WIRELESS FACILITY TYPE 1—3: DETAILED SUBMITTAL CHECKLIST REQUIREMENTS Does applicant have a right-of-way license? 0 Yes 0 No TYPE 1 AND TYPE 2- Must include a sketch showing: Under the wireless facilities standards,is the proposal ❑ Dimensions considered?(check all that apply): 0 Small Cell ❑Macro ❑ Street Name ❑ Site Address How many install sites are proposed as part of this permit application? TYPE 3- Must provide 4 sets of plans (sized 24 x 36 or 22 x 34) and an electronic version of all submittal The proposed equipment is located on which of the following: items. The plans must that include: 0 Public Right-of-Way 0 Private Property ❑ Cover—Site,Vicinity,Abbreviation,Legend If equipment is to be located on private property,describe the ❑ General Notes (City,Water,Sewer,etc.) type&use: ❑ Street(Plan,Profile) ❑ Water,Storm and Sanitary(Plan Profile) ❑ Water Quality Facilities ❑ Grading ❑ Landscaping/Tree Plan ❑ Composite Utility Plan(Electrical,Phone,Gas, Storm, Sanitary,Water,Signage,Street Lights,etc.) ❑ Details ❑ Traffic Sight Distance ❑ Signing and Striping ❑ Street Light Plan and Photometric O Engineers seal/signature 0 Sheet label(project land use name,revision and plan log block,dates and sheet numbers.) ❑ Engineer's Construction Estimate Additional Submittals (per land use conditions,if applicable) ❑ Traffic Report ❑ Storm water Drainage Calculations ❑ Geotechnical Report 0 Preliminary Access Report(Sight Distance) 0 Proposed Plat O Pathway Design 0 Water Provider Approval City of Tigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • wwwtigard-orgov • 503-718-2421 • Page 3 of 4 9 SW "Y " S I Edge of Pavement iI Streetlight ,ia/Ditch Q rrr .y I • r S�%• ® I1 I J. T-'Frop'ogrtf sow'erTr" i1) aj Nt I Existing House 1 'Q .e: I Existing 1 >e I Driveway F-I 3e 1 _ 1 v op !I p Ir, J ' t ,^i a Iel� �i�/ .I I. r1 g dI ;�' 1 • v 1 1 Q+" 1 rr >I 1 1 61 0 I Existing Shop 1 r _ = 1 J I = 1 • Powerpole I • e I �`^ la 95' • 1? 1 Fire Hydrant(FH) I 1 Scale: 'I"=30' I I I I I I TYPE 1 AND TYPE 2: MINIUM SKI:TCIT Rl;QT.IRIAIEN'I'S (Put N/A if not applicable) North arrow Property lines&dimensions Existing utilities locations (sewer, storm,water) Street& street names All existing structures Proposed work Existing curb or edge of pavement Utility&street light poles Existing S/W or D/W apron Slope of property Trees City of Tigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • www..tigard-orgov • 503-718-2421 • Page 4 of 4 Page 84 2011 Edition Stationary Lane Closure with Flagging Diagram 320 Diagram 320 covers total closure of one lane of a two-lane, two-way roadway. See the detail inset for the layout if using a single flagger to control both directions of traffic on low volume roads (less than 400 ADT)with good sight distance as discussed below. 1. Use truck-mounted flashing warning lights on work and protection vehicles. See Section 4.3—Lights and Lighted Signs for exceptions. 2. For added visibility, a truck-mounted arrow board or PCMS in caution mode may be used. 3. Flaggers at each approach are required if any of the following conditions exist: a. Night Operations. b. Work space is over 200 feet in length. c. Sight distance is less than 750 feet from each approach through the lane closure. d. Traffic volumes are greater than 400 ADT. 4. The length between the Flagger Ahead signs shall not exceed one mile. Use Diagram 340—Lane Closure with Pilot Car if exceeding one mile. 5. Cones should be used to outline the work space when curves or other roadway alignments prevent clear direction for the motorists to pass the work space safely. 6. Cones along the work space are recommended when posted speeds are 45 mph or greater, when working under heavy traffic or when travel lanes are narrower than 11 feet. 7. Extended queue signing (see Diagram 5-4) should be used when traffic queues extend beyond the initial advance warning sign. 8. When flagging near an intersection, the "Flagger Ahead" (CW23-2) sign should be visible to traffic entering from any side road. Additional advance warning and Flagger Ahead symbol signs may be placed on the side road(s). 9. Sign set-up and flagger placement shown may be used for intermittent full road closures of 20 minutes or less. 10. The"ONE LANE ROAD AHEAD" (W20-4) sign is optional and should be considered on high volume or high speed roads, or when extended queues are expected. Chapter 5 December 2011 2011 Edition Page 85 Stationary Lane Closure with Flagging Diagram 320 Q12R QQ 0 >Q i 2 w� 0)A m ° O .� zis dr 0 O p / 1 I N cn / A.a 1- - Ira + I 0 \ a� w 1— \ G I • UOa ise a) • 0 N o L t0 a 1 • �‘ 2 M fn ® < I E 1 • III o r 45 • 6i • 1 (12 z 3 O • N !IlE Ii I • mE •• I! • O ma Ov I• •• ate° Li_I — Y w a °'O r /WQ° m 4 Itr m m .0 J I m Sign Spacing and Buffer Lengths(feet( 4 1 • ww p p ., Posted Spacing Between Signs Buffer ( J z 0 u6 �: Speed A B C Space V \.. Q rd p 20 50 .,.,.0 25 100 100 100 75 30 100 35 125 //'1 p 40 350 350 350 150 O O n 45 180 50 500 500 500 210 55 250 December 2011 Chapter 5 41To OVERHEAD LEGEND ` I NORM LOCATOR 14185' f 4 • SURVEY GRIDBDOHOARY $ _REMOVCASA MOORMCRIIN0_NRTALLFACYINR V _MTLLLRDRIOENALCAEWTM.O.00 V'ACNITIS POLES WL2PL-24B1: 44 Install: 1—POLE CLASS(I,2,3,4,HI,HZ S) NCO PL 50-3 NT-CL 1'SOUTHEAST EDP=T I2 ._-, 14270 POLE HOOF? D1 T43D0 D163 y�gpgNEO PoLE VSME/3 FRAMING TRANSMISSION 6 DISTRIBUTION TREE CODES&MOM 1P ZSKVA OH 120/240 J L IV l ll:tl 14e0 FRAME DISTRIBUTION{C10T1D,MV 0001 5 ACCOUNTS Ot —TIPS TANG,PIN) 15 2 KVA _FRAME DISTRIBUTION{C10T1D,MU DDN 142 C/O FIST OH TAP FFR SC.DE.FOLIT 3-IN PVC COND UNIT W/12'SETS FRAME Al-L15'-T,550B NORTH ✓ D10—IIPH SLACK SPAN EIPoY) 0109 C G113 SECONDARY 7,550W ���LLL CONDUCTORS Remove: NurA PL 45'-4 PAL6R LOW NEUTRAL _ NONSTANDARD SLACK SPAN AND HI NEU FRAMING ANTALL ADIL ACM ON PRIMARY., 1P 25KVA OH 120240 7.2 NT1C5 AT ACM t LOW MEUTRSL 192 C/O FIST OH TAP EQUIPMENT 3-IN PVC CONDUIT UNIT Al c REPLACE FUSE ITT (2)C16 PRE POLLED ER ROWS) /A. Ie[c TOPPED re KILL ST 1, 4:80 reu..ssLR�E ANCHORS GUYING RI9I IIIxI 1${gJ q L+ 6 II A4q 1, • o O ,A IJ S O c N O 6 b �J MCI=ME O EEckR5T�wwR�I 14010 AL-T%1 14385 14005 A 6' b G G b 20UY: ©'©Q'©EAN`I::i AJrM EYOP mf�000 e 000E= 3127 mJ 194; 13159027 14320 i925 • 14945 C I. 3F. Dio _.._.._.... 142N SOa S VIEW TERRACE ST of 13 281 2 14215T HN 9 AC5R mr R 25 5946 - l -U. 0 R25 _ _. E1 VICINITY MAP 5O':9 pore 2 I 9920 14415 LAIN=40' GOO l4, \It Ina In 86 Open G TOME - 4,225 :14010 A I 1 IGU=E 9E95 . NIL PL,3547: MP OWNED POLE MAIM • - Install: PL50'-3 1'SOUTHEAST ' EOP=10' DR Sams,En/HERE.Ca mn.USGS. 0106 MMm1AR INCREGBAOR9118001),0' Al-L iT-10,1538 aln.METI.E51 Gni.IAGE Rena 3124 WEST 016-PRI-4,999R E4Aoo u.n[GRfrnsiOAT mane ...3 ROG Q{a19nNNq JIOI,[GROAT,MOM 1..R G16-NEUT/SEC-5,169# WS User UmmooN 05002 52ACSR Remove: ANY DEVIATION FROM THIS DESIGN MUST r.1 142 15 T /� SWINEI ST ED N - BE APPROVED BV THE POE PRO/ECTMANAGER� NON-STANDARD SLACK SPAN AND HI NEU FRAMING Al CALL 811 BEFORE YOUOIG ATTENTION 1 POLO r DneoN UW emalers wU lG muoW eveE94DDPrzD F TEMP!PAMPER cowls), /HIN\ SrTRE OAMON UNIT NOTIFICATION COMA • TOPPED TOC SAFETY mE MY PIOM LBSI[�LLI-0MGa�H �60 TO CCOPI(Fw _IELeD rD MILE \FIRS NNOTINGTION EST NTER UTIITY ION L LE0001-IS8TJ 14525 • TO REQUEST UTILITY LOCATES CALL THE OREGON BNNC�imlbelOW. UTILITY NOTIFICATION CENTER,811 AT LEAST FAN Won you LEE 2 BUSINESS OARS PRIOR TO EXCAVATION POE CONSTRUE LION DRAWING • AS.BURT IFM:ATION 6ANEEC Ig fn0NS CORRECTED iCMO I._.. 99W 990C F01.093 GAG: m 3Pnrnl Foreman. ryGRERRLANIeTuGa Re MIm5ut0I C0IP1) SOPM•ENG REVIEW' IASBUILT BY DESIGNER. y�e US8202020 n n-50 It IAE 1070001 11000004545 I M2RT/626 << REPLACE PL3547 AND PL2431 TOPS ARE ROTTEN OUT OTRIGCNI ' 45025299 �� O�A TIGARD 13 r22%iT 3'G B94 6W vIE W TERRACE ST,TIGARD.97224 a34 I 445 `/ IE DESCRIPTION RE PLACE%354T AND PUG)VATS ANGLS POLES.TOPS • -. ARE ROTTEN OUT SHEET _II COUNry EOMINe n1Tv 0 20 90 DD Mom B10 CU DX uuw..l.5..o=I. WASHINGTONIA C21t18 IrANR IOF1 cesR L.HI fvo0E a41V,v O A L 1 N BURL HIRE 5.03.729.1102 1ALY55A MAROUEZ I—Lm 0 PORTWiD GENERAL ELECTRIC OO.ALL P GITS RESERVE>