Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
PFI2020-00464
IN " CITY OF TIGARD PUBLIC FACILITIES IMPROVEMENT PERMIT s COMMUNITY DEVELOPMENT Permit#: PF12020-00464 T I f;\A.1) 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2421 Date Issued: 12/08/2020 Parcel: SEG695 Jurisdiction: Tigard Site address: Subdivision: Lot: Project: CenturyLink National Project Description: SEG 695/705/ 11600 SW 72nd Ave/Joint trench along 72nd Ave to place(1)-4"conduit, street-cut& joint trench along SW Baylor to place(1)-4"conduit. Place(1)-304B handhole; street cut 5'x 5' area tp [;ace(1)-444-LA manhole. Class of Work: FEES Description Date Amount Type 1 -Utilities(gas, electric, data) - Total Owner: REQUIRED INSPECTIONS Call 503-639-4175 for the IVR inspection request line or visit the City of PHONE: Tigard website at www.tigard-or.qov to schedule inspections online. Contractor: LA LONDE ELECTRIC PO BOX 2220 ESTACADA,OR 97023 PHONE: 5039698491 Applicant: TODD HURD 214 E 24TH ST VANCOUVER,WA 98663 PHONE: 5034676422 Please sign below to indicate acceptance of conditions and return a copy with the proposed work schedule along with names and contact information of responsible parties before beginning work. Permittee/Applicant Signature: See applicationIssued By: VA /ATM Special Conditions(See Attached) Note:THIS PERMIT DOES NOT COVER WORK ON PRIVATE PROPERTY Conditions for PFI2020-00464 Type: Condition Name: Status: rer.Lty: PFI_Utilities 01 -WORK SITE REQUIREMENTS Applied Notice Applicant must comply with all applicable provisions of federal and state law,the Tigard Municipal Code, and the terms of any agreement with the City of Tigard regarding work to be done pursuant to this permit. PFI_Utilities 02-WORK SITE AREA Applied Notice The work area and approach roads shall be maintained in a clean condition,free from obstructions and hazards. The spreading of mud or debris or storage of materials or equipment of any kind upon any public roadway is strictly prohibited and violation shall be cause for immediate cancellation of the permit. The City may at any time order immediate clean-up and suspension of work to accomplish clean-up. PFI_Utilities 03-WORK SITE EROSION CONTROL Applied Notice Prior to starting work,effective and approved erosion control devices must be installed and maintained meeting the Clean Water Services and DEQ requirements. The City may at any time order corrective action and suspension of work to accomplish effective erosion control. PFI_Utilities 04-WORK SITE REPAIRS Applied Notice Disturbed landscaped areas shall be restored or replaced. Existing signs, pavement markings, mailboxes, etc. shall be reinstalled or replaced,with like kind of material. Obtain City approval of restoration work. PFI_Utilities 05-TRAFFIC CONTROL SPECIFICATIONS Applied Notice Applicant shall provide traffic control according to the current edition of the"Manual on Uniform Traffic Control Devices [MUTCD]for Streets and Highways", U.S. Dept. of Transportation, FHWA,current edition,American Traffic Safety Services Association [ATSSA], and Oregon Temporary Traffic Control Handbook[OTTCH]. PFI_Utilities 06-TRAFFIC CONTROL PLAN Applied Notice Submit a job specific traffic control plan. A copy of the approved traffic control plan shall be readily available at the work area.Traffic control devices,flag persons, etc., shall be in place prior to initiation of construction work and shall be effectively maintained. PFI_Utilities 07-TRAFFIC CONTROL ROAD CLOSURE Applied Notice Public roadway shall not be closed to traffic, at any time,without obtaining written approval from the City Engineer. The applicant is responsible to provide 48 hour advance notice of traffic flow disruptions to affected businesses, residents and area wide Emergency Services: 503-629-0111 (Tigard Police Dept.,Tualatin Fire & Rescue)and to 503-962-8140 (Tri-Met) and 503-431-2345(Tigard School District) and other service providers impacted by such closure. PFI_Utilities 08-TRAFFIC CONTROL ADVANCE WARNING Applied Notice Advance warning of traffic disruption shall be provided to the public by placement of an approved advance notification sign at each end of the construction area 72 hours (min.) before initiation of construction work. PFI_Utilities 09-TRAFFIC CONTROL PROPERTY ACCESS Applied Notice Access to existing properties shall be maintained at all times, including normal delivery service and mail service. Obtain City approval of any access closures. PFI_Utilities 10-TRAFFIC CONTROL WORK HOURS Applied Notice Work is permitted in daylight between the hours of 7:00 a.m.to 7:00 p.m. Mon-Fri unless otherwise authorized by the City. PFI_Utilities 11 -TRAFFIC CONTROL LIMITED WORK HOURS Applied Notice Hours of construction work on collector and arterial roads will be limited to 9:00 a.m.to 3:00 p.m. unless authorized by the City Engineer. Work will not be permitted on collector and arterial roads between 3:00 p.m. to 9:00 a.m. unless authorized by the City Engineer. PFI_Utilities 12 -TRAFFIC CONTROL MODIFICATION Applied Notice The City reserves the right to add to or modify traffic control requirements as necessary to effectively control traffic and to assure public safety. PFI_Utilities 13-DRAINAGE CONTROL Applied Notice Drainage shall be controlled within the work site and shall not adversely affect adjacent private property, public property and the receiving system. The City may at any time order corrective action and suspension of work to accomplish effective drainage control. PFI_Utilities 14-UTILITY NOTIFICATION Applied Notice Oregon law requires following the rules adopted by the Oregon Utility Notification Center. Said rules are set forth in OAR 952-001-0100 through OAR 952-001-0080. Copies of said rules may be obtained from the Center by calling 503-246-1987. If you have any question about the rules, contact the Center. NOTE: Damage to utilities shall be corrected at the permit holder's expense. PFI_Utilities 15-UTILITY LOCATION CONFLICT Applied Notice Applicant must verify all existing utilities for both vertical elevation and horizontal location prior to start of work(pothole before digging if necessary). Should conflicts arise and redesign or relocation of facilities be necessary, it shall be done at the applicant's expense. Changes must be approved by the City in advance of work.Applicant shall coordinate the work with affected utility agencies. PFI_Utilities 16-TEMPORARY PATCH Applied Notice A temporary hard-surface patch shall be placed on trenches within roadways at the end of each work shift. Obtain advance approval of patching method. No trench shall be left at any time in an un-safe condition. Applicant is responsible for and is liable for hazards or damage resulting from the prosecution of the work. PFI_Utilities 17-REPAIR OF EXISTING FACILITIES Applied Notice Work under this permit shall include repair of existing facilities(roads, ditches, etc.)as may be necessary,as determined by the Inspector,to overcome deterioration or damage which occurred in conjunction with the work authorized by the permit. Corrective work shall be done at the applicant's expense. PFI_Utilities 19- PRECONSTRUCTION MEETING Applied Notice Before initiating any construction activity,the applicant shall coordinate with the City's inspector, <Insert Name>at<Insert Phone#>,to establish a preconstruction meeting. PFI_Utilities 20-NOTICE TO COMMENCE WORK Applied Notice The applicant shall notify the City's Inspector twenty-four(24) hours prior to commencing work, prior to any staged inspection,and after completing work covered by the permit. PFI_Utilities 21 - PERMIT/PLAN ON SITE Applied Notice A copy of the permit including a Certificate of Insurance, and all attachments, and a copy of the approved construction plan and all amendments shall be readily available at the work area. All work shall conform to the permit terms, conditions and provisions and to the City approved permit plans, and approved plan amendments and to the City's standards and specifications and to these General Conditions. Changes to any of these must be approved by the City, in advance of work performance. PFI_Utilities 22- DAILY INSPECTION REPORTS Applied Notice Applicant shall submit daily inspection reports, on a weekly basis,to the City's Inspector. PFI_Utilities 23-MONUMENT PROTECTION Applied Notice Existing monuments, property corners, and survey markers shall be protected. Replacement shall be at the permit holder's expense. PFI_Utilities 24-VALIDATION OF MATERIAL/CONSTRUCTION Applied Notice The City's Inspector may, at his discretion, require tests and or reports from the applicant to validate claims of material or construction adequacy/compliance. Such tests/reports shall be provided at the applicant's expense. PFI_Utilities 25-EMERGENCY CONTACTS Applied Notice Provide to the City inspector, in writing,the names and 24 hour emergency telephone number of two(2) persons who have authority to resolve problems,take corrective action and, in general,will be responsible in case of any emergency. The applicant shall notify the City Inspector, in writing,of any/all assignment changes. PFI_Utilities 26-RIGHT OF ENTRY/EASEMENTS Applied Notice Applicant to obtain proper right-of-entry and/or easements prior to starting work. Proof of right-of-entry or properly executed easements,shall be provided to the City. The City shall in no way be construed to be liable for the applicant's failure to obtain or provide for proof of right-of-entry or easements. PFI_Utilities 27-PRIVATE PROPERTY AGREEMENTS Applied Notice Provide the City a copy of an executed agreement[s]from the owner for each private property disturbed by construction activity. PFI_Utilities 28-AS-BUILT DRAWING Applied Notice 1,2,3,4,5 28-AS-BUILT DRAWING One as-built drawing showing all new public improvements,including any revision made to the previously approved construction plans and, also, any improvement which may impact an existing public system or facility,shall be provided to the City by a registered civil engineer along with an engineer's certification of installation compliance(Certificate of Compliance). 1,2,3,4,5 28-AS-BUILT DRAWING One as-built drawing showing all new public improvements, including any revision made to the previously approved construction plans and, also,any improvement which may impact an existing public system or facility,shall be provided to the City by a registered civil engineer along with an engineer's certification of installation compliance(Certificate of Compliance). One as-built drawing showing all new public improvements, including any revision made to the previously approved construction plans and, also,any improvement which may impact an existing public system or facility,shall be provided to the City by a registered civil engineer along with an engineer's certification of installation compliance(Certificate of Compliance). PFI_Utilities 31 -OTHER Applied Notice Other City of Tigard PFI#: 2020-00464 • .III • ENGINEERING DEPARTMENT TIGARD Public Facilities Improvement (PFI) Permit PROJECT INFORMATION N638335-N.797005 TYPE OF WORK Project name: El TYPE 1—Franchise Utility Work Joint trench along 72nd to place(1)-4"conduit; performed by NWN,PGE, or utility Brief description of project: agencY Street-cut&joint trench along SW Baylor to place(1)-4"conduit; Place(1)-3048 ❑ TYPE 2—ROW Sidewalk/Driveway/Sewer handhole; Street-cut 5'x5'area to place(1)-444-LA manhole. Work performed for the purpose of: • Sidewalk installation or repair • Driveway approach installation and repair SITE INFORMATION • Sanitary sewer lateral installation and Location (address if available): SEG695 / 705 main line tap ❑ TYPE 3-Full Scale Development Work 11600 SW 72nd Ave, Tigard, OR 97223 performed with land use approval which includes any of the following • Subdivisions or Partitions APPLICANT INFORMATION • Street widening Name: CenturyLink National • Mainline installation for sanitary sewer. storm sewer, Tigard water, and Tigard Mailing address: 214 E 24th St water service area City/State: Vancouver, WA 98 Zip: 663 ❑ 'TYPE 4—Small Cell Technology Phone: ID TYPE 5—Tigard Triangle (503) 467-6422 Email: todd.hurd@lumen.com Phone: (503) 467-6422 NOTE: Type t and 2 applications may be Contact name: Todd Hurd emailedtorowpermits@tigard-or.gov. Phone: (503) 467-6422 Email: todd.hurd@lumen.com CONTRACTOR INFORMATION ❑ Same as applicant Name: La Londe Electric; Attn. Bruce CCB Number: 174854 Mailing address: 1000 NW Commerce CT City/State: Estacada, OR Zip: 97023 Phone: (503) 969-8491 Email: Bruce@lalondeelectric.com/Sabrina@lalondeelectric.com ENGINEER INFORMATION Name: K&B Technical Solutions Mailing address: PO Box 2529 City/State: Clackamas, OR Gip: 97015 Phone: (907) 230-2311 Email: Jeff_Mettert@kbmail.net ADDITIONAL INFORMATION Estimated value of work is required(if over$5,000):$ 15,000.00 (within the public right-of-way) Is work related to a LAND USE DECISION? ❑Yes 0 No Case number: City of Tigard • 13125 SW Ftall Blvd. • Tigard,Oregon 97223 • www.tigard-or.gov • 503-718-2421 • Page 1 of 4 APPLICANTS NOTE: Person specified as"Applicant"shall be designated"Permittee"and shall provide financial assurance for work,if required by the city pursuant to TMC 15.04.140. * With the exception of a utility operating pursuant to a valid franchise or license with the City of Tigard,when the owner and the applicant are different people,the applicant must be the purchaser of record or a lessee in possession with written authorization from the owner or an agent of the owner. The owner must sign this application in the space provided or submit a written authorization with this application. Franchised or Licensed Utilities are not required to obtain the owner's signature on the application. I,the applicant,certify that: • To the best of my knowledge,all the information provided within this application package is complete and accurate. • The above request does not violate any recorded deed restrictions that may be attached to or imposed upon the subject property. • If the application is granted,I will exercise the rights granted in accordance with the terms and subject to all the conditions and limitations of the approval. Jeff Mettert 11/30/2020 Applicant's or authorized agent's signature Print name Date Property owner's signature (if required) Print name Date STAFF USE ONLY Case No: PFI2020-00464 Permit fee: - Received by: AL Date: 11/30/2020 Approved by: /6~4 A Date: 44/7/0D10 Notified by: /lt/ Date: 2 `6 2-6W City of Tigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • wwwtigard-or.gov • 503-718-2421 • Page 2 of 4 DEVELOPMENT ENGINEERING FEES Public Facility Improvement(PFI)Permit: INITIAL PFI PERMIT FEE Part 1: Required submittal fee is 10%of the Net PH Permit Fee.See below for calculations.Minimum of$300. NET PFI PERMIT FEE Part 2: All non-water system improvements engineer's estimate X 7%(less the initial PH Permit Fee). WATER LINE CONSTRUCTION FEE Part 3: All public water system improvements engineer's estimate X 12%. FOR STAFF USE ONLY FOR STAFF USE ONLY TYPE 4: SMALL WIRELESS FACILITY TYPE 1—3:DETAILED SUBMITTAL CHECKLIST REQUIREMENTS Does applicant have a right-of-way license? 0 Yes ❑No TYPE 1 AND TYPE 2-Must include a sketch showing: Under the wireless facilities standards,is the proposal ❑ Dimensions considered?(check all that apply): ❑Small Cell 0 Macro ❑ Street Name ❑ Site Address How many install sites are proposed as part of this permit application? TYPE 3- Must provide 4 sets of plans (sized 24 x 36 or 22 x 34) and an electronic version of all submittal The proposed equipment is located on which of the following. items. The plans must that include: ❑Public Right-of-Way ❑Private Property . El Cover—Site,Vicinity,Abbreviation,Legend If equipment is to be located on private property,describe the 0 General Notes(City,Water,Sewer,etc.) type&use: 0 Street(Plan,Profile) ❑ Water,Storm and Sanitary(Plan Profile) ❑ Water Quality Facilities ❑ Grading ❑ Landscaping/Tree Plan ❑ Composite Utility Plan(Electrical,Phone,Gas, Storm, Sanitary,Water,Signage,Street Lights,etc.) ❑ Details ❑ Traffic Sight Distance ❑ Signing and Striping ❑ Street Light Plan and Photometric ❑ Engineers seal/signature ❑ Sheet label(project land use name,revision and plan log block,dates and sheet numbers.) ❑ Engineer's Construction Estimate Additional Submittals (per land use conditions,if applicable) ❑ Traffic Report ❑ Storm water Drainage Calculations ❑ Geotechnical Report ❑ Preliminary Access Report(Sight Distance) ❑ Proposed Plat ❑ Pathway Design Water Provider Approval City of Tigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • wwwtigard-or.gov • 503-718-2421 • Page 3 of 4 Cr) - \\ .. '. S I dge of Pavement 'F— Ditch —i Peibi, Streetlight . _t . 1 ' i� I 'o '• i 1 i I--7'io'poslfSoweuTine` 4, I I a.) , vi N= Existing House <, �; 1 Existing -1 Driveway 'ai i ,,?1,*1. ifs A gI ! I F,:rtin_ ;a,p Powerpole Ii I Z.11 ~j `_ �f Ia - - - 95 - - - I ='fn�urt. Iro I Fare Hydrant(FH) i I I Scale 1'=30' 1 I 1 I I 1 I TYPE 1 AND TYPE 2: MINIUM SKETCH REQUIREMENTS (Put N/A if not applicable) North arrow Property lines&dimensions Existing utilities locations (sewer,storm,water) Street&street names All existing structures Proposed work Existing curb or edge of pavement Utility&street light poles I Existing S/W or D/W apron Slope of property Trees City of Tigard 13125 SW Hall Blvd. • Tigard,Oregon 97223 • www.tigard-orgov • 503-718-2421 • Page 4 of 4 MATCH TO SHEET 4 • I 1 I .-01—— _ _ CONSTRUCTION NOTES 3I I `Int / All C DITIO TO BE RESTORED TO u�OR 6.04-- I�� / MONO ROAD BARRIER BETTER CONDITION. I 2. All OTHER UNITIES ARE BASED OFF EXISTING • i I6- 6CV 11600 TAYLOT LOCATES OR UTILITY STRUCTURES. 20.00''----T- I I A SW 72ND AVE STREET-CUT AND NEW 3048 HWDIIOLE 15136DC0330D ' 17 CO' 2.11.. PROPOSED-177'S1N[[r-CUT.JOINT TRENCH, PERMITTED UNDER CRY OF l 3. R IS ETE CONSTRUCTION CONTRACTORS • ' I I L I J0 AND(1)-4'PVC CONpf PLACED AT A MN. 7MARD PERMIT/PF72020-00427. SING. 1LITY TO CALL FOR LOCATES BEFORE � OF 36.BELOW GNOME BY OTHERS AND E p - 1111 I : i FERRETED FOR OWNERSHIP BY CNN. 1 STREET-CUT A 2'WEE BF-25' I 14.D0-- LONG AREA OF ASNMU FW �i_ PROPOSED 5'x5'STREET-CUT AND M4-U - _ JOINT TRENCH. F MANHOLE MH-01 PLACED BY OTHERS AND LEGEND 4 PROPOSED ABB'JOINT TRENCH AND 1-4" s 7 I -. RRMTIED FOR OWNERSHIP BY CNN. () PROPOSED TCA VAULT ` 8 -.. PVC CORDER PLACED AT A MN.OF 36" PERMITTED AND ^' M- JOINT TRENCH —--— }, BELOW GRADE BY OTHERS AND PERMITTED s L �tSS'"- L Q n FOR mow*BY GTN. PLACED BY OTHERS. - ' PROPOSED STREET-CUT [—— d 1 NAME • [ 449-L 1„ \ PROPOSED H4lIIHOLE N®TYPE er,//IX' M4iA 2 i o MH-07 OWNER CTLn ®� ��a 1PG3'E6 z;.Ej�E 3018 o NAME 7 T"Y'--� __ n n I n -—_—®. ' n I I`C�, " PROPOSED MANHOLE ®TYPE / •_._,. i �} 1 "'1�" yt- -�� -�L" '1s•{ J T—_8 OWNER N I ti T— /Ci, ! DWir 1- .. --too _ .. COSTINGMUTTMNCONDUIT - HEW RICHE OF WAY •r, I- I 12.00'-I DOSING RIGHT OF WAY .n I PROPOSED-255'JOINT TRENCH AND(1)-4"PC CONDUIT - —sW 72N0 AVE-- --- .- - - _ EXISTING PROPERTY UNE -- — F PLACED AT A MIN.OF 36-BELOW GRADE BY OTHERS AND --- __ 1 0 PERMITTED FOR OWNERSHIP BY CNN. -~� EXISTING FACE OF WRB@ o IXISTNG EDGE OF PAVEMENT a EXISTING GUARD RAIL -.- EXISTING STORM DRNN so DISTING STORM _. _ ___<,— Q. �_.-�.._N z. Y.----.oc-_.a__Y._.m_...vc ,L• 1_.. +' EXISTING SEWER i EXISTING STORM MANHOLE CATCH BASH O\_- IMING MANHOLE "I7' ® \ / 1 —~� COSTING WATER - " .__./.----.. E t EXISTING FIREGAS HYDRANT �`. I--..--. 1 EXISTING q5 \ COSTING ELECTRIC "— 1 _ EXISTING TELEPHONE s �' -h--+n „ . n ' EXISTING CAN 1162E ' — -- --. r COSTING COMMUNICATIONS SW PACIFIC HAT 1 I 7501 a 7275 SW DARTMOUTH ST SW DARTMOUTH ST ,/W, f LrwiIH31 EN.E:JAr CenturyLinle " 1 x nvw1AS-OLI41 II/NI/e0 M.0. JI.M II III/b/30 M.O. J.T.M. GPoGIWL IQ WE ERRS DE90Y dWiINL EN! N- 3"°N4 Level(3) �fR LEVEL J ENGSEER TOOL Mild.6039/91.6I22 ENAEHINM FRY FA9 Toordial SoRlens PROJECT NURSER IESITE-JENOINCTLN OR-3 I.131s) LOCATOR 110.0 WI THIN Re 10 70 TOR.CRMTBJ — DRAWER ME:N.tpa.M.N1ata Mk,NR3_OILTp3_UnNL aW/Wok/.M14fY3.MMl..3�W.A.3 CONSTRUCTION NOTES 1. All WORK AREAS TO BE RESTORED TO VICE OR BETTER CONDITION. 11600 2. ALL OTHER WADES ARE BASED OFF COSTING SW 72N0 AVE LOCATES OR UTILITY STRUCTURES. PROPOSED TG VAULT PROPOSED"255'JOINT TRENCH AND(1)-X'PVC CONDUIT PERMTIED MO PLACED AT A ME OF 36'BELOW GRADE BY 0111ERS AND J. IT S THE CONSTRUCTION CONTRACTORS PLACED BY OTHERS, PERMITTED FOR OWNERSHIPBY CHIT. RESPCNSIBRRY TO CALL FOR LOCATES BEFORE a MGM. (..7_.��_.�_._.. I ,� LEGEND — Q }� -8 .8 L 8 o I 1-z557 JOINT TRENCH L o 8 PROPOSED STREET-CUT 212 NAME —. ° '�----a.--. ,,, PROPOSED HA OE ®TYPE OWR F __—r ..712' _ - "/ -'a, �n .- NAME w �n— f�—__ .o PROPOSED MANIIOIE B TYPE - --• - ,o --..._.i N N .. a—_—mow-�' F- O _ - _ --AAA-- -.:.- .. x. __... .. A. x. F, W EXSTNC MNY PoLE ® D 2 _ o -SW 72Np AVE- - rn COASTING CRN CONWU ---- QPROPOSED JOINT TRENCH 19.5'(M')MD-111'(N)MD(1)-1 « - - -- - -_ - - --- OF E%SDNC R/W ALIGNMENT —- < PVC CONDOR PLACED AT A MN.OF 36-BELOW GRADE BY - 01TERS MID PERMUTED FCR OWNCFSIP BY C6UL U NEW RIGHT f►MAY .n F DOSING RIGHT OF WAY .✓ __^'. —..—.a ,a---.w—tea AC EXISTING PROPERTY UNE — •"` aa� DOSING FACE OF CURB 8 .o- °°�--tea DOSING EDGE OF PASEMENT �- .6-6' �.a DIETING GUARD RAIL - - ly EOSTING STORM DRAM • DOSING STORM MANHOLE DOSING STORM CATCH BASIN A .n n ^- DOSING SEWER . --n —,- .N. _� EXISTING SEWER MANHOLE f 6'-_� _n---.:- DOSING WATER •-_- _. EXISTING FARE HYDRANT EXISTING GAS COSTING ELECTRIC COSTING TELEPHONE 11626 COSTING CAN SW PACIFIC HWY EXISTING COMMUNICATIONS CI). Leue(3)'a„MM I). CenturyLink• 11 S EN �Vb/z6 uo. J.E.N.J.E.N. 0OS-W C 111 1 Ai V.66/zo u.a. a.a.u. oNNNN N0. MlE M.OE9pN OWNING .AWFM Mq aAafa lit lNE. LOW L EK"MOWER NW M1E-E01M1.04II -....4r.-..- 1.031141MING Ma MO tocnaaal AaMM1. P ROEM MYER M065nN.106)6)CILM ONJa@a.lsW) L OCATOR:11000 SW 70,00w 0 1a Nord.M N= CRANING NAME.uo-aunmam_M.o,mn_atTa.a_Tms._ ENN.m c.... STALE-I•.za NEE,T: A CO 0 CONSTRUCTION NOTES I. Na NOIRE AREAS TO BE RESTORED TO UNE OR BETIER CONDDIOIL 2. NJ.OTIIS UTILITIES ARE BASED OFF EXISTING TAXLOT LOCATES OR umm STRUCTURES. IS136DAD0902 11530 SW 72ND AVE 3. DIIS THE CONSTRUCTION CONTRACTORS RESPONSIBILITY 10 CALL FOR LOCATES BEFORE DIGGING. 3048 WWDHOLE Mi-02 PLACED LEGEND BY OTHERS AND PERMITTED FOR JOINT 1NLWI,H OWNERSHIP N1.BY C � —--— • PROPOSED SUELI-CUT I [__] " • "` +/.� .n--. - V1.02 0 8 0 8 ,� PROPOSED NWDHOLE H©TYPE -/" " _ ( CTLN .. OWNER c`ii �1 ^f--.n -� NAME _ T PROPOSED MANHOLE ©pOIWpNE�ER o — ter__— - _= -,-4o.--� .'� (-i 1i1--•-- EXISTING unLm POLE ®FOIE D 5.D0' 8 _ F'-- ---- - SW 72N0 AVE— — -- U _._ EXISTING EAR CONDUIT — -_ - _ COSTING R/N'AUGMENT - l.4 NEW RIGHT OF WAY ./. - - PRO OSED JOINT TRENCH 19.s'(W)IND�112'(II)ro FOIE 6080 I- E%SPNG RIGHT of WAY .n _, AND(I)-1^fhC CONDIIf PLACED AT A MN.OF 36^BELON W EXISTING PROPERTY LIE — — — 0C�0` "� a � �x .� �� GRADE Bf OTHERS AND PERYIRED FOR OIYTERSIIIP BY CiIX. I EXISTING FACE OF CURB --'0C --,,,,--- ,,,,;Al' - W EXISTING EDGE OF PAVEMENT �� «—__ ,a_�N----arc rep F EXISTING GUARD RNL 2 EXISTING STORM ORION I- EXISTING STORM MNLlHOIE (I " g EXISTING STORM CATCH BASIN 0 EXISTING SEWER -.nm-----„ �, EXISTING SEWER MVIHOLE EXISTING WATER �' " - . 1 _---..-. .r ___'^----"!" . -„ _ EXISTING FRE HYDRANT RISING GAS EXISTING ELECTRIC - EXSTIIG TELEPHONE 11626 USING CAN SW PACIFIC SEA, WSWCOMMUNIf.AIIONS - ) • Llrwll31..0.tfir' CenturyLink• 'a ON 2 11/90/20 u.0. AT.N. AS-I ONION I I uET III11/0/90 M.D. J.I.u. Om awl xo Mre 000 CE91aA DOWIOC. COMMENT IITw.11BV0.10W. Level(3Y (;YIAlIw9N4 LEVEL O ENGINEER Todd TW-609M7.022:2 �yp.� E 'frsRNCA1M:MB T.Y.d wren. ERE.IEOI M..NER'.TN69N96X.NI666(CRHERJpEF111]1) LOGipN:I IB00 SW 12 d A•e 0 IC' 1 0EH NO9 000WBON TUNE wmwamO.JMq_mm_0.*wLTN.y._ _ fN 2200 F.wI MFp EI P. 4.. SG.LE: 1_TO' .Bf I SW L CONSTRUCTION NOTES I. ALL WORK AREAS TO BE RESTORED TO TEE OR BETTER COMMON. 2. ALL OTFER LITOTES ARE EKED OFF EXISTING 11500 7135 LOCATES OR UTILITY STRUCTURES. SW 72ND AVE SW BAYLOR Si 3. D IS TIE CONSTRUCTION CONTRACTORS i RESPONSRAIIY TO CAL!FOR LOCATES BEFORE DIGGNG. 7� { i h l o �.R _n-- LEGEND .. JOINT TRENCH �-'-----�_ .�—s s `•—. "' PROPOSED STREET-CUT I- m m I LU " 1 r" PROPOSED HANp10LE HH NAME m LL. — __ `_ _—. `�- SW BAYLOR ST- OWNER 0 J _ _ ~ I —_-' PBOPOSEO-5'STREET-CUT.AND 12 JONT NAME 1 PROPOSED MANHOLE TYPE I F (..n')___ TRENCH RID(1)-1'PVC COMMIT PLACED AT OWNER 4 _ A MN.OF 36'BELOW GRADE BY O1HER5 AND ` I —.� —_—,m__„ REMITTED FOR OWNERSHIP BY CRN. DOSING IIIWIIY PORE ®POLE EU ._ — -,- a -— COSTING GE ER CONDUIT —--— (. T • ten. - T - _._ /�° R/W ALIGNMENT .n---`n I n— .n.._,,_^'n �. _.. _. — ory, - -"' .6666., I NEW RIGHT OF WAY + + `/' +n +rv— EXISTING RIGHT OF WAY —+_ EXSTNG PROPEfOY UNE CDSTNG FACE OF CURB -�� PROPOSED-177'STREET-CUT,JOINT TRENCH, FXSTNG EDGE OF PAVEMENT AND(I)-/'PAC CONDUIT RACED AT A MN. S. DOSING GUARD RML —.ow— Of 36'BELOW GRADE BY OTHERS MD EXISTING STORM DRAM -- -t^ PERMITTED FOR OWNERSHIP BY CRN. RESTING STORM MANHOLE (J EXISTING STOMACATCH BASIN -1 I I EXISTING SEWER < COSTING SEWER MANHOLE EXISTING WATER ..-- 1166C 7160 7130 EXISTING FIRE HYDRANT -' SW 72ND AVE I SW BAYLOR ST 1 SW BAYLOR ST E%ISIINC GAS EXISTING ELECTRIC -- - OXISING TELEPHONE —_— EXISTING GTV EXISTING COMMUNICATIONS 1 ' I n.; PowoP)..a.he CenturyUnk .5-BUILT 8. / 1 n I 30/2 RI JtO D RCSIDN I 1 lir CMGIN.LL IMIE ENG OESMN ORY1ING CGWENT Ka...we.Ca �(3)W Call*you w Ne. QQQ ��11U BI LEVEL a G,® M L Todd Mull-!W. .BIIQ EMGNFEABIG Mak Rua reciniad ea9.B MN3BN PROJECT MAIER N .flRBBM1N IC ORi10EA15NB) LOCATION:'MIA MTM Ave O' -- TINM,aa MAWNWNABS Nuu]6M.AIUM_IRO_t ma_D2TP.V V.+ _ ew raw r._.M aw.a.p a worm) SCALE. I-=30 4erlET 4 C! • I CONSTRUCTION NOTES SW PAi OR ST 1. ALL WORK AREAS TO BE RESTORED TO LIKE OR BETTER CONDMON. __ 2. NI OTHER UTILITIES ARE BASED Off EXISTING IODATES OR MIX STRUCTURES. ,� 3. R UTIL IS TIE CONSTRUCTION CONTRACTORS RESPONSIBILITY TO CALL FOR LOCATES BEFORE fm awE`=7,W-Bi�—L1m I 7130 SW EAYLOS ST DIGGING. 110E • Mg -- — _. _. LEGEND IAXLDT Inn F — — 15136G100902 Sw 22N0 AVL COSTING OEM FACILITY _— -_� WRECK-OUT AERIAL FACILITY —X- -41 X- 7160 I SW BAYLOR ST mowUMY POLE ® p wAnx-om zq a' EASING ARK Fnn6st...211f�tu BETWEEN POLE 30 ANO POLL 6666. E% RIGHTNG RJR ALIGNMENTWVMEW OF WAY 1I6J0 1513603033.311 EKW TING RIGHT OF WAY --- __�.SW)2U0 AL EXISTING PROPERTY LIE — - . 1 7 BIEIX-0UT SIT OF' EX SIt6 AMDOMES I 1 T SW nxWODArE I PITON A IEW POLE fElli IOW WImL-0N —BETI[III PoIE 8690 WO POLL 656E "n a/.— AI PILE®. i SEGO OWL WRECK-CUE j '� 7 —_'^__ — T$ 1[ >f X -M X MO fi(/(--1C—"!( X X X ppO�E�EE #. It�.-,- })F 3C'k"n Xi33.3./.—X--._ 1p8(E ppOE — --SW 2210 AVE- BBBI _ _ As 1O6 �, 6�0 ®1 AFIN WI[Q-0OW —"� ,,, a Fo[a I 11626 I ffi01 I 2P5 SW PACIFIC NWY SW 0ART1KKR11 Si SW GWRp11TN ST ►,FI 1Pevel(3)'.«a.,�►�CenturyLinlr I-BA i IIIII2 Vw/so N.o. J.l.0 WEA95N I 1 I�/w/Ro uo �1u omrnu M. W.IE VW CCSW^own.* CCMWENI OWWw. Level(3) Gfy16WEnIw�1 LEVELS ENGINEER TWO NW•WM AWI.WM ENGINEERING FIRM:NIB TAtl6E S661Abw PROJECT NWBER.N8]89]SN.MOOS(L IJI011Sg1L131X6) p ]yI05LOCATION.1188B SW m.d Aw Lip TpN1 W raw 1 OPAWiWq ILU1E.NNRIMN'.*516I 1hm Ie_rya_1n.y._ EW 24 Aw wf eW e;yA.MheWLW 6 6 SCALE:1-60' Se z."4A�M.RM�;- TYPICALS , .I T1 uR s idWOO rEXISTNG GRADE O� \'� 1/ . n 6M. �``4". / ..6L u� !3 l - _ \ 1lI SIRUCNNAL NOTES 36'MIN.DEPTH `-WARNING TAPE a " L PUN J le 13MEm5 � 1�.�.�,.�. RACKFlLL-8•LAYERS A view A k,�.1n.", i BACKFILL-COMPACTED 0 90% "i "r"� •• vr�.a..a a�'°,m :`mA� 5' / /� 111�t 1I I i'i�1 L�11 "EI,M"i"w gib♦ IHOPE DUCT I�`mur C , / »I.,...._�i T w+`� u.......,...:....l.w....... CLEAN BACK FILL ��` �`11I"oE al° `• I itI ° �:.m _BACKFlLL-COMPACTED EARTH 0 90% ^i � F 4e . SHOP NO J 44L I\} '�I 4 it 'I nsna Rwwto�s ram. TYPICAL DETAIL - 41 a° /� VIEW Tt6w a 56(roM IMRC MEC) ..LML..-'4'1y`' , _ A g- TYPICAL DETAIL - #3 11111,66 IIMJL1 PRE-LAST 111 05M.A.SILE-25/00161 TYPICAL DETAIL - P 2 2Y311L.50616636 A55516.6 16/(1)01-66E 2.66 5(I)7 I/'1006 65.300666762 O AMMO 66561306 MI • 6Y 16E 6E6 MIX CAM OR m¢6516E0 17-t® 1 06PYL SW 6A 1K01 L 1505110 5.1101 111M I. DX ILL 5666.55 A I.I60 6'POW 1-071 WO 1676g1 M RQ 551".<5164 0112665 56665 1-516 N 65 MASAO iMdM IN111.LACY[06136E 6f I20129N0 1.51O11.6101566 M9115 NA MO I_ 651.41610115EM.M. . Or 61.--1 —6'WO ME 1.07165 t. A WNW r 6651M'95UPA6L WM OM MI IWk • I01-M9LMY.O 161.0 02550116L15M52 /� P 6 ® L...... " "CenturyUnk• MOONED Mwt x P M5M m6 a PF31(M a IL55 TIW)'fRll Mp1116 OW . .. &p1Lt P.RLpf 577617711.OR[6[6 SINEI.RPM M%.gflR Y.MYY I,K` WAl ®HSMFA161�/ P • PaA2 O I. P Kg TM 615 5 61L5 III 1 EH 51 4. ME 5' I AS-euii M6,MOM 66015610 E PMOLM 10 M 6A EILF 6 ME ° 11/31/10 4.0. J.I.M. 6En561 T 1 S IiN VALL 60I H WOF LM61{6016511W• IIIL II�EW Y,O. Ji.0 6nGiHLL er«660 M.0 wlvw'Im. it.°0661 Mr.. 70166ENT 6 M PNgOIf 555119016 56115I1065 35 GY6. GNYY.m MLL..b6Il. OrR16ry WS P-515 6-51660 6-50 .I>•4 POM P... 6 P. 126 6101011615 M NW56,56 NV 110.P-61. TYPICAL DETAIL - N4 um,�60M630.Todd Mal-OWM1 OIJ'NEEANl6.iL 15461.1.0.19015110. efitflO PAflEM L-0II SFCI61 PRGMI:1105/ NM.A..lIIWI�LMOINION-t56M) LOCATION:n6W B6 T7272 TAAL083avrm qUW W NAME SWI rat Aan sS 160_1i0LA..11 µ_ SW rat A..tl AY6M'YP.M.M 911Ei 6 O 6 �1 `f. CenturyLink To whom it may concern, this letter is to authorize K&B Technical Solutions to submit permits on behalf of Centurylink (National); furthermore,CTL NTL will be bound by the permit requirements set forth by the permitting agency. odd Hurd SR.OSP Engineer Oregon Field Services Centurylink National 214 E 24'h St Vancouver, WA 98663 p:503.467.6422 e: Todd.Hurd@centurylink.com 11. CenturyLinke Curtis Porras Network Implementation Program Manager(OSPE-NTL) 214 E 24th St,Vancouver,WA 98663 0:(503)416-1516 C:(503)349-1246 `�re ►,��� CenturyLink LUMN- Todd Hurd Todd.Hurd@lumen.com November 30, 2020 214 E 24th St Vancouver, WA 98663 Re: CenturyLink, Inc. Launches New Brand, Lumen Technologies This communication is to advise you that on September 14, 2020, CenturyLink, Inc. announced the launch of a new brand — Lumen Technologies, or simply Lumen. We operate in Tigard as a local utility company and telecommunications company. Going forward, you may see both the CenturyLink and Lumen logo or names on our company trucks, employee uniforms, websites, permit applications or other communications with us. You may see email from some in our company with the Lumen domain (i.e., xxx(a centurylink.com may change to xxx@Lumen.com) and other correspondence from us having one or both brands. Our local regulated services will continue to utilize the CenturyLink name and brand and we apologize for any confusion the introduction of the Lumen brand for our enterprise services may cause. No changes to the legal names of the CenturyLink, Inc. operating companies providing services in Oregon are anticipated as a result of this announcement. We will continue to operate under those legal names, which include the following: Oregon Operating Companies: Broadwing Communications, LLC CenturyLink Communications, LLC* CenturyTel of Eastern Oregon, Inc. d/b/a CenturyLink CenturyTel of Oregon, Inc. d/bla CenturyLink Global Crossing Local Services, Inc. Global Crossing Telecommunications, Inc. Level 3 Telecom of Oregon, LLC Level 3 Communications, LLC Qwest Broadband Services, LLC d/b/a CenturyLink Qwest Corporation d/b/a CenturyLink QC United Telephone Company of the Northwest d/b/a CenturyLink WilTel Communications, LLC *Please note that this entity may use the Lumen and Lumen Technologies brands for its enterprise customers Because there is no change to the corporate names of our operating companies in your state, we do not need to make any changes to our permits or other agreements. However, you should update the email extensions for your contacts for our company (first name.last name@Lumen.corn). Additional information can be found in the press release announcing this change: https://news.lumen.com/2020-09-14-CenturyLink-Transforms-Rebrands-as-Lumen-R. Should you have any questions, please contact at the number above. Sincerely, Todd Hurd Page 108 2011 Edition 5.5 Multi-Lane Roads Right Lane Closure, Multi-Lane Non-Freeway Diag. 500 Diagram 500 covers work which closes the right lane of a multi-lane non- freeway road. If closing more than one lane on a multi-lane road, provide a minimum tangent distance of 2L between the end of the first lane closure taper and the beginning of the second lane closure taper. 1. Use truck-mounted flashing warning lights on work and protection vehicles. See Section 4.3— Lights and Lighted Signs for exceptions. 2. For added visibility, a truck-mounted arrow board or PCMS in caution o mode may be used. 3. When the posted speed is 40 mph or less, the RIGHT LANE CLOSED AHEAD signs may be omitted. 2 4. Placement of signs in a non traversable median or other median that is not a two-way left turn lane is required for lane closures any time there is room for a truck to be parked on the left, out of the travel lane. When there is no room for a truck to be parked on the left an additional RIGHT LANE CLOSED AHEAD sign should be placed on the right side and placement of signs in the median is optional. 5. If flagging is needed for work vehicle ingress/egress, use Flagger Layout Detail (see Inset). Sign Spacing and Buffer Lengths(feet) Posted Spacing Between Signs "Buffer" Speed A B C Space 20 50 25 100 100 100 75 30 100 35 125 350 350 350 40 150 45 160 50 500 500 500 210 55 250 60 285 65 700 700 700 325 70 365 Chapter 5 September 2016 Ili 2011 Edition Page 109 Right Lane Closure, Multi-Lane Non-Freeway Diag. 500 1 1 1 1 . I I . . Protection Vehicle • WPM(both Optional) • See Chapter 4 1 1 j •0 • 0 11N 1� * I 1 1 At•Y nil BE • 6. PREPARED I • L ) •. L TO STOP I I I •• I tO ,y Flagger Layout w Detail . 1 A B *See Note 4 ,�* RIGHT LINE 0n4 0 1 1 tIt AHEAD ROAD` * -; WORK \AHEAD September 2016 Chapter 5 Page 118 2011 Edition Lane Closure at Intersection with Flagging Diagram 620 Diagram 620 covers work within an intersection when normal traffic control must be interrupted. Work vehicles may or may not be in the work space. 1. During flagging, traffic signals shall be turned off. Contact the road jurisdiction for approval and assistance (see Chapter 3). 2. For multi-lane facilities, traffic approaching the intersection shall be reduced to a single lane on each approach. See Chapter 3 for information on flagging through intersections. 3. There should be one flagger for each approach. One flagger may control two adjacent approaches if sight distance, low volumes on side roads, and flagger position allows for safe operation and clear direction to motorists. For low traffic volume intersections (fewer than 400 entering vehicles per day), one flagger may be used. 4. The "ONE LANE ROAD AHEAD" (W20-4) sign is optional and should be considered on high volume or high speed roads, or when extended queues may be expected. Sign Spacing and Buffer Lengths(feet) Posted Spacing Between Signs "Buffer" Speed A 8 C Space 20 50 25 100 100 100 75 30 100 3S 125 40 350 350 350 150 45 180 50 S00 500 500 210 55 250 60 285 6S 700 700 700 325 70 365 Chapter 5 September 2016 2011 Edition Page 119 Lane Closure at Intersection with Flagging Diagram 620 ROM WORK AHEM 46 a1 1 PREP" eE II i0 STOP .1 ® A (Optional i• foot MOE '� ®mv WORN ROAD I AHEM •I A B B C Butler . ..�` . K . K 4 ®. ,ro.MECH CBBA T PREP • ® BE r0 STOP® • MIL LW I • �dl A B eE PREPAREDTo STOP B (ano.n wE 1 t c� ROAD September 2016 Chapter 5