Loading...
Report OFFICE COPY Commercial Fire Subscriber Submittal Guide City of Tigard Senior Center 8740 SW Omara St Tigard, OR 97223 • CITY OF TIGARP,, REVIEWED FOR CODL COMPLIANCE Approved: 1J OTC: [ I Pcrmtt#: Fpsa.O - C� 0 J) .� Address: s g )�>; 5�,.� 0 cz e Prepared By: Suite#: PERFORMANCE By: Date: SYSTEMS INTEGRATION 7324 SW Durham Rd Portland, OR 97224 info@psintegrated.com (503) 641-2222 Phone (503) 641-1464 Fax Job#: MON109461 Date: 10/17/2020 PLEASE PROVIDE COMPLETED NFPA 72 RECORD OF COMPLETION AT 1es►411a4.4��y_SPECTiON Scope of Work: Installing new radio for communication Document Index: • Site address map • Fire communicator equipmentlocation • Block Diagram(interface to existing fire alarm system) • System calculations • Wiring diagram • Operations Matrix • Manufacturer's data sheets • AES Build Sheet Site Address Map: r., : .. . j . , . . .. - 1111 _„. . _ ; j 1 \ , \ • .. I ...A. 01 8740SW Omara St ,1,..& .... . .0 ! .!! • • 1!2.74.:!'. \ r ;. --i-..a;-„, . .,.o. .. . -.!.. -,, :. f • - ' : -•4'...:-.:- '1:1,.;' . ' rat , . ..... . i 11 ' ' 1 11I'''' ''''-' c ' 1 . ...2-.? .. if ," • - , .,.. . . ..., ... • a_ 4')fr ''N'Il•71110.A' . '...p ..t • ,t -'• ,‘1,. , ,44‘ - •-ler:,' . . -'-; ' ,., ..- .I' .,4•. . . 4....... ,-1 '-'' ',:,,,-: . - 44-- • ,-.4 .;,. 1 , :- ,..r..7 . _ . • :.• i.**'''. 1 .: ..01r4!' 'et‘7 /6 1 110-1.t- et, • -.'. fk: .•,."..--* • "' 1.,..-7:.. - ,,,, : Nii, . t, #h• 4014 1•3•.."..,,:•• . -- ... ,•*.• 'N 1111.1.1111.111pPORF e. ll ..m gi I ,Pr•Lt 71-.'.-..) :": ACOUNT451 01-5655 • , ACS 01503)641-6761 2T. • . 1. . . egr2 MI 0 r I:1 cx . .4166...,. . Block Diagram: NEW EQUIPMENT TO REPLACE POTS SYSTEM EXISTING FIRE ALARM SYSTEM(TO REMAIN) (NEW) FIRE FACP TYPICAL NAC OUTPUTS SUBSCRIBER HORNS,STROBES,BELLS... 0 TYPICAL ALARM INPUTS DETECTORS,PULL STATIONS... TYPICAL SUPERVISORY INPUTS DUCT SMOKE DET.,TAMPER SWITCHES... POT I STEM NOTES(CLASS B SYSTEM): Ti)120VAC MAIN POWER FOR THE FIRE ALARM SYSTEM(RE-USE EXISTING). THIS SYSTEM REQUIRES A DEDICATED CIRCUIT THAT IS LABELED. "FIRE ALARM CIRCUIT"AND IS ACCESSIBLE ONLY TO AUTHORIZED PERSONNEL. 0 CIRCUIT BREAKER LOCATION(S)SHALL BE PERMANENTLY NOTED AT ALL FIRE ALARM PANELS Battery Calculations: AES 7707 BATTERY CALCULATION WORKSHEET Standby Transmitting Source Description Current Current 7707 MAIN BOARD 0.200 1.200 TOTAL 0.200 1.200 20%Efficiency Factor 1.2 1.2 24 Standby Hour Required Ah Required for Stby 5.760 5 Alarm Minutes Required Ah Required for Alm 0.120 Total Ah required for cabinet 5.880 Battery Capacity Supplied (1)12Ah Wiring Diagram: Antenna 7194 A } InTREIPro l/- Rase Button aN(ENE1 \O J7 sw1 USBr USR WI!Met tort- AVM COTTVEI MIOn POPO P`ograrranrc FR Power 7880LC2 "1iu-1 MEV Opt1o4Z 110 Transceiver Trbl TX RX WO AIM 115 ul IMP nrr NOTE Orrlranscover (see NOTEI ytwed yell'prrHlutl t 11411117107 Norm SYpPly 11 sinus lndNator LEOS 7RY DC Output Antenna or FRCP ReER016d 24V DC 114 Ompur .:.h_ ri LSI IA ENCLOSED IN CONDUIT, -E /�` 11+ BAT - (ze.NOTEI �X J9 0 V-j) INS LCD i-R 7712— RED IuOI 7orx Input Card Pv;t.rP:u. 7707.044 PETER 10407712 INSTRUCTIONS • RnVrr LCO MR INSALEAT+ON AK.SMIRNO Wsun6rr If,:F,F s.,rr-r 111 Zone Header Mau 6<c:m FARM GROUND WRNEEND B f_DIPSW1 I 1 UE 10 HEYNOD ENCLOSURE RION TO TO 77E 1 NOPLATONS %.5:7 REFER 1b INSTRUCTIONS FOR I FOR WALLET ION AND PORING 113 Power DE TAR m N1- Option 3 OQ UANNf. �— 7711 ICAP Input Carl u.tR paplosnL PODAJe ro.._I 00NEC Rep mea �.O [CONNECT \,/0 2'Na C;) OEW IE Output .mi— 114 1f A O-TERMINAL 1I1-4-R� � Earth Ground NON 1INPUT SENSITIVE V WEN TO Al 7701 NSTRl1CTION rowFRrNW1 u, FOR SySTEMCOWIGURA'ION- 7 COANTIRLEOEVCILRt K 15 AN NC lZ+ BAT - 11416V/24V ♦ - arw�Xo- 1 1.7" TERMINALS a NOT m POURm WIRING MUST RE NO NC C NO NC C E 1 6 Vl ( O ' O O SOISITWE InCI 0s10 INf4MEID L J L J 155 Power Option iPOUMt RUMNAGI RED BLACK WC j.4. TAN SECURE{ORMC CONNECT - III' + - 5 Iv VAC MFE1110 a07M1 REFER TO 40N40 —1_ air 1 INSTRUCTIONS FOR MAX LOBO.2MI DC - + IA MAX.RESISTIVE INSTRUCTIONS WA 1750 1 every EOM/101MM WOUPERMSED NSTALIN10N AND Ilnnunvotnr CONFIGURATION WIRING. 17 VIEW MO GN cell type WIRING MUST EC NOTE WNW, 10.11 Rh..CInEEI,oemo Dep.rdern ENS LOST D IN CONDUIT /140 AnNUIiDNIxI SEE INSTIUCTICNS ION IANEN/ PLUG IN OASS 2'MIN LIMITED TRANSFORMER CONNECTED SET WE RIOURIEMINIS YE NSTRUCT M ONS LORPROVEO MODELS DIPSWlTp Or. ALL CACUNTS POWER LIAII TEO TNN45FCIMEN MUST If ENCLOSED IN ABWE W 16R0ENCL E1R:E7T BATTO N LEADS. AU[MUMS DUPE RMRE0. D71O7WRTO11A System Configuration Diagram Control Panel Dialer 2 7 7 0 7 u•-1 Dialer 1 nc 7794A Pro'. M'uneaml 0 77075100104 • Fire Alarm Alarm Relay — 7707 Control Panel TroubleRelay E Local Supervisory Relay A""f0ip1 Dialer 2 Dialer 1 t 7794A • Remolo An..ntlltn! 077075100203 Operations Matrix: OUTPUTS 2 c z_ m r • F W F N Q Z ▪ Q Z `�$ L.„3 m w u CO mIn EXISTING FIRE ALARM SYSTEM • CC u N OPERATIONS MATRIX Z Q °° W z = Li W LL OCD G = LL - cf) cC Z 0 = F 9 Z I 2 .n Z m W 2 cc S 6 H Z ra_ cc J U' • Z m_ Z y p 0 m 0 cc Z F N . 0 • q m W • V Z LL M o K • Z LL F vi BUILDING FACP(NOT SHOWN)AC POWER LOS BUILDING FACP(NOT SHOWN)BATTERY POWER LOS FIRE SUBSCRIBER AC FAILURE FIRE SUBSCRIBER CHARGER TROUBLE FIRE SUBSCRIBER LOW BATTERY CONDITION N EXISTING FIRE ALARM SYSTEM OPEN CIRCUIT EXISTING FIRE ALARM SYSTEM GROUND FAULT EXISTING FIRE ALARM SYSTEM TROUBLE EXISTING FIRE ALARM SYSTEM-ALARM EXISTING FIRE ALARM SYSTEM-SUPERVISORY Manufacturer's Data Sheets &AES Buildsheet: aes-corp.com ES /i . CORPORATION a# 7707 Fire Subscribers b IntelliNet 20 Grp Introducing a Newer, Smarter 0 Alarm Communications Platform • 6 New Feature Highlights AtAEs l!H^rya; • Leverages state of the art technology • Applies advanced security protection • Offers flexible power and configuration options• 0 • Engineered for backward compatibility with legacy systems NFPA LISTED • Enables future ready capabilities • Provides instant subscriber status through front panel with Power and Trouble LEDs, a backlit LCD display, and Menu/Silence button • Improves functionality with an adaptive Graphic User Interface(GUI)for programming via smartphones,tablet and PCs • Plus many more... Key Benefits that Make 2.0 the Best Alarm Monitoring Solution Ever • Built upon the solid foundation of AES-IntelliNet patented mesh radio technology for use in private licensed wireless networks • Protects subscriber units against unauthorized access and rogue activity with a password protected Dealer Code • Makes programming and streamlined troubleshooting easy with user friendly interface • Adds integrated supervision of AES-IntelliPro full data module • Provides versatile power options: (1) Direct from the Fire Alarm Control Panel(FACP)without requiring a n electrician onsite and without Subscriber backup battery (2) Directly from the FACP with Subscriber backup battery;or (3) Traditional installation with plug in Class 2 low power transformer • Allows for enhancement upgrades and an expanded number of new features to be added easily with highly flexible and scalable alarm communications infrastructure • Rigorously tested to the highest industry standards and future ready to meet emerging NFPA code and UL standards www.aes-corp.com Enhanced Wireless Fire Alarm Monitoring Powered by AES enhanced mesh radio technology, IntelliNet 2.0 7707 Fire Subscribers are next generation universal wireless communicators that provide advanced security protection for any new or existing alarm monitoring network.The AES Model 7707 is ideal for commercial fire applications.With the AES-lnte!liPro full data module option,they are the ideal drop-in replacement for Plain Old Telephone Service(POTS)lines. The red metal enclosure comes with a key lock and front panel LCD backlit display with intuitive view that provides an instant visual of the subscriber status.The user friendly GUI makes iteasyto program AES subscriber units via a smartphone, laptop,tablet,or integrated Universal Serial Bus(USB)—without the need for special cables or having to use a handheld programmer.Additional knockouts make it easier to mount for faster installation. IntelliNet 2.0 Private Wireless Mesh Radio Network DI Burglary _ D Subscriber fI - - _ ' - ' - - - - - -- --Y Firr r s 14 y Subscriber , j ` I ` Subscriber - Aft Network Management tree. �I am Sin EMI , ... a„ - -'I PilmeryArS.MniilNrtRNeint, I Al Alarm 770. Penal r 'I Se,ondery Ae S.mum Receme. I -`````„_ B B Alarm Automation ..._ _ I11 C A - - CS IP Links All C u;tomcr Loc ttian__� Mesh Radio Technology I t t Central Monitoring ,Statc �: peas>t alarm syra s v a sma t routs{ a ,mtss.onrli 3se,mds The IntelliNet 2.0 Fire Subscriber has an 8 Zone modular design for expansion with normal and reverse polarity, POTS and DACT interfaces with an option for the 7794A AES-IntelliPro full data module add-on accessory board. AES subscribers' intelligent software automaticallydetects new hardwareand devicesto reduce installationtime. An AES certified WiFi accessory allows seamless wireless connectivity for configuration and programming.A laptop, Ethernet cable,or a Wi-Fi USB dongle is required for IntelliNet 2.0 programming, handheld programmers will not work with 2.0 units. A FACP Power Supply Adapter is required for certain configurations when using flexible power options.The forward compatible design allows for feature add-ons,engineered to adapt seamlessly with future software upgrades as technology advances.IntelliNet 2.0 allows configuration cloning for faster installation time. The AES 7707wasdesigned with quickconfigurationand installation in mindto make iteasierforfieldtechnicians to get in, out,and onto the next install. Visit our Fire Marshal Resources web page for official NFPA and UL Listings: http://aes-corp.com/products/fire/fire-marshal-resources/ www.aes-corp.com How to Order 7707 Fire IntelliNet 2.0 Fire Subscribers 2.0 PREMIUM(UL&ULC Listed,Available Now!) 7707P 88 IntelliNet 2.0 Fire Subscriber, 8 Zone, 8 Supervised Zones,with integrated onboard Local Annunciator, Red Enclosure 7707P-88-ULP IntelliNet 2.0 Fire Subscriber,8 Zone,8 Supervised Zones with 7794A AES-IntelliPro and integrated onboard Local Annunciator, Red Enclosure 7707P-44 IntelliNet 2.0 Fire Subscriber,4 Zone,4 Supervised Zones,with integrated onboard Local Annunciator, Red Enclosure 7707P-44-ULP IntelliNet 2.0 Fire Subscriber,4 Zone,4 Supervised Zones with 7794AAES-1ntelliPro and integrated onboard Local Annunciator, Red Enclosure 2.0 FEATURE ADD(Pending UL Review) 7707P-88-M IntelliNet 2.0 Fire Subscriber,8 Zone with Multiple Communication Technologies(MCT), Red Enclosure 7707P-88 ULP-M IntelliNet 2.0 Fire Subscriber,8 Zone with 7794A AES-lntelliPro,and integrated onboard Local Annunciator plus MCT, Red Enclosure 7707P-44-M IntelliNet 2.0 Fire Subscriber,4 Zone with Multiple Communication Technologies(MCT), Red Enclosure 7707P-44-ULP-M IntelliNet 2.0 Fire Subscriber,4 Zone with 7794A AES-IntelliPro, and integrated onboard Local Annunciator plus MCT, Red Enclosure 7707M-UPG IntelliNet 2.0 Fire MCT Software Upgrade 2.0 ACCESSORIES 7794A Standalone AES-lntelliPro Fire full data module add-on accessory board with firmware for new IntelliNet 2.0 units only,cannot be used in legacy units 77-WiFi AES certified WiFi adapter 77-FACPA FACP Power Supply Adapter for internal mount 77-FACPA-KIT External installation hardware for t-wayJunction Box Legacy Fire Subscribers 7706-ULF Integrated Fire Monitoring System, Red Enclosure 7788F-ULP-P Legacy Fire Subscriber, 8 Zone with 7795 AES-lntelliPro(7794 full data module, 7762 hardware supervisory module,and 7740 Local Annunciator), Red Enclosure 7788F-ULP Legacy Fire Subscriber,8 Zone,8 Supervised Zones with 7794 AES-lntelliPro, Red Enclosure 7788F Legacy Fire Subscriber,8 Zone,8 Supervised Zones, Red Enclosure 7744E-ULP-P Legacy Fire Subscriber,4 Zone with 7795 AES-lntelliPro(7794 full data module, 7762 hardware supervisory module,and 7740 Local Annunciator), Red Enclosure 7744F-ULP Legacy Fire Subscriber,4x4 Zone,4 Supervised Zones with 7794 AES-IntelliPro, Red Enclosure 7744F Legacy Fire Subscriber,4x4 Zone,4 Reversing Polarity,4 Supervised Zones, Red Enclosure LEGACY ACCESSORIES 7794 Standalone AES-IntelliPro Fire full data module add-on accessory board for legacy units only, please see 7794A above for IntelliNet 2.0 version www.aes-corp.com Technical Specifications 7707 Fire DIMENSIONS ALARM SIGNAL INPUTS/ZONES PORTS 13"H x 8.5"W x 4.5"D - 8 individually programmable Ethernet for configuration and messagecommunication (33cmH x 21.5cmW x 11.4cmD) E.O.L.type zone inputs • 4+4:4 reverse polarity input and 4 USB access for software upgrade WEIGHT individually programmable E.O.L.type zone inputs REMOTEANNUNCIATOR 5.8 lbs(2.6 kilograms) AES Model excluding battery • Optional 7794A AES-Inte/liPro for 13 lbs(5.9 kilograms)with full data via Contact ID, Pulse, supervised Remote Annunciator, Modem Ile and Modem 111a2 10 Ah battery ULLISTINGS COMPATIBLERECEIVERS R A D I O F RE QUE N C Y UL 864 10th Edition 7705i AES-MultiNet Receiver Standard Frequency Range: Standard for Control Units and 450-470 MHz Accessories tfor Fire Alarm Systems ULC C 0 N Fl GU R A T I O N I N T ER F A CE Contact AES for other UHF and S559-04 1 Edition Equipment for Fire VHF frequencies Signal Receiving Centres and Systems Web browser capable device accessible via smartphone,tablet,laptop,or PC ANTENNA 2.5 dB tamper resistant antenna TROUBLE OUTPUT—ACKDELA CUR RE N TC ON SUM P11 ON included,mounts on enclosure Y/ANTENNA CUT Standby w/charged backup battery: Optional remote mounting antenna 200 mA(1.2 A Transmitting) available Form C relay,fail secure,rated 24V DC Standby+charging backup battery:900 1A resistive,unsupervised mA(1.9 A Transmitting- MAX) POWER INPUT RESETBUTTON POWEROUTPUT AC SOURCES Transformer:Class 2 16.5V Located on main circuit board 2 or 5 Watts Factory AC nominal output set 1.9 A max current(40 VA MIN)ELK OPERATING TEMPERATURE ELK-TRG1640, EN CL O SU R E M AT ERI AL MG ELECTRONIC SALES MGT1640, 32 to 120°F(0 to 49°C) Steel with paint finish or AE51640(not included)DC SOURCES(includes FACP) S T O R AG E T E M P E R A T U R E 24V DC Regulated Power Supply FI NI S H C O L O R with Subscriber 14 to 140°F(-10 to 60°C) Red Rechargeable Battery 1.9 A max current RELATIVE HUM IDITY VISUAL IN DICATORS BA C K U P BA T T E R Y 0 to 93%,non-condensing Front panel LCD (2 10-12 Ah, UL recognized leadacid gel disx a0 alphanumeric character backlit cell, size based on subscriber RECHARGE CAP AB ILI T Y Power and Trouble LEDs configuration Will charge 12V battery size (ALM,Trouble,Tx,Rx,WA) from 10-12 Ah Contact Us For pricing and availability or to learn more about IntelliNet 2.0, please call your local AES Sales Representative at (800) 237-6387 or email sales@aes-corp.com. 00000 www.aes-corp.com AES Corporation I 285 Newbury Street I Peabody, MA 01960 United States /707_O5252017_F y�tv. ea -.v. '-') ,_,..\ /AO J J ' r_ I 1 '�� BATTERIES Werker SLA technology offers high-density power that out-performs traditional lead acid batteries. The Absorbed Glass Mat(AGM)construction is designed for efficient gas recombination and allows for maintenance-free operation. Werker SLA batteries maintain their high capacity with a design that is resistant to damage caused by deep discharge. Every Werker SLA battery is inspected to ensure the highest standards in materials and fabrication. Battery Features: Charger Features: • Werker SLA AGM batteries contain a proprietary grid alloy New! SLA Chargers formula.This formula combined with the advanced plate curing techniques offer improved performance. • Regulated trickle charge for"float" mode charging • Werker batteries contain a unique electrolyte formula with a • Short circuit protected special sub-colloid additive for higher reliability and longer life. • Reverse polarity protected • More than 1,000 discharge/recharge cycles. • Thermal protection in case of overload • The unique construction and sealing techniques of the Werker • Alligator clips battery guarantee leak-proof operation. • Color LED to indicate state of charger • Heavy-duty lead calcium tin alloy grids provide an extra margin of performance and service life in cyclic applications,even after repeated over-discharges. • Quality Assurance Engineers monitor and control the entire • production process. Werker soot=B�) �e• SLA/AGM BATTERIES Flame Capacity Dimensions Height Over Weight Flame Capacity Dimensions Height Over Weight item* Volts Retardant Ah Ix Via H lin.) Terminal(in.) (lbs.) Item a Volts Retardant Ah L a W x H(in.) Terminal(in.) (lbs.) 12 - 0.8 3.78 x 0.98 x 2.40 2.4 0.8 12 - 7.5 5.94 x 2.56 x 3.74 3.98 6.0 12 - 1.3 3.82x1.69 x2.05 2.28 14 12 - 12 5.94x3.90 x3.74 3.98 9.3 12 - 2 5.91 x0.79 x3.54 3,54 17 12 - 18 7.13x3.03x6.57 6.57 13.9 ,.,V o,1^v,^q 12 - 23 6.97 x 1.38x2.40 2.64 2.0 u,vn ,�svl 12 - 26 6.50 x 6.93 x 4.92 4.92 20.3 12 - 3.2 5.28x2.64 x2.40 2.64 3.2 12 - 35 7.72x5.16x6.10 6.57 25.4 WKA321.3F WKA1212F2 12 - 4.5 5.51 x 1.89x3.98 4.21 4.4 12 - 35 7.72 x 5.16 x 6.10 7.09 25.4 WKAl2-251 12 - 5 3.54x2.76x3.98 4.21 4.0 WKA121O4OL 12 Y 45 7.80 x 6.54 x 6.85 6.85 35.7 vv nHiz-aer 12 - 7.5 5.94x2.55x3.74 3.98 6.0 wnalz-�erva 12 Y 60 9.02x5.43x8.19 8.35 40.3 WO v,arc.nr VVM101lt-Jn� W KAl2-s.1A W KA32-3v Continued on Next Page WKAl2-5F W KAl2-44C/FR FormereJnformation please contact WKAl2.55c/FR Re a IacementUFShat .,136 ... Ries.o e the Power fe, __.. www.ReplacementUPSbattery.com Phone: 952-217-6611 Email: info@replacementupsbattery.com Continued from PreviousPege Poge2 SLA/AGM BATTERIES Flame Capacity Dimensions Lx Height Doer Weight Flame Capacity Dimensions lx Height Over Weight Remit yotb Retardant All WxH(in.1 Tenninal(in.I (Ibs.l Item# Vohs Retardant Ah WxH(in.I Terminal(in.l (Ibs.l WKAl2-55P/FR 12 V 60 9.02 a 5.43x8.19 9.06 40.3 WKA6-144 6 14 4.25x2.80 z5.51 5.51 6.2 WKAl2-80C/FR 12 V BO 10.24 x 6.65 x8.31 8.46 55.1 WKA6-14T1 6 14 4.25 x 2.80 x 5.51 5.51 6.2 W11Al2-80158 12 Y BO 10.24 x6.65 x8.31 9.06 55.1 WKA6-1412 6 14 4.25 x2.30 x 5.51 5.51 6.2 WKAl2-10nr/FR 12 Y 100 12.09 x 6.65 x8.31 8.46 72.8 WKA6-14T3 6 14 4.25 x2.80 x 5.51 5.51 6.2 98KA32-1001/FR 12 V 100 12.09 06.65 06.31 9.06 72.8 WKA6-42F2 6 42 6.3803.4606.42 6.69 15.9 W16512-125/FR 12 Y 140 13.43 x 6.816 11.06 11.3 104.7 WKA6-4258 6 42 6.3803.4616.42 6.85 15.9 WKA6-1.3F 1.3 3.82 x0.94 x2.05 2.28 0.7 WKA4-4.5F2 - 4.5 1.85 x1.85 x3.98 4.21 1.3 WKA6-3.3F 3.2 5.28 x1.34 x2.40 2.64 L6 WKA6-5F 5 2.76 x1.85 x3.98 4.21 2.1 WERKER SIA CHARGERS WKA6.55P 5 2.64 x 2.64 x 3.82 4.53 2.0 Dimensions LK Walgld WKA6-7.2F 7.2 5.94x 1.34x3.74 3.98 3.0 Dung Volts mA WxH Qn.l (Ibs.I WKA6-B.2F 8.2 3.90 x2.24 x4.53 4.53 3.8 WK5V500 .. 500mA 2.36 x2.04 x.73 0.58 WKA6-10F 10 5.94 x1.97 x3.74 3.98 4.4 WK12V500 1:V 500mA 2.36 x2.04 x.73 0.66 WKA6-12F 12 5.94 x1.97 x3.74 3.98 4.6 WK6VI000 e'J 1000mA 2.54 x2.32 x1.95 0.86 WKA6-12F2 12 5.94 x1.97 x3.74 3.98 4.6 WK12v1000 12V I000nu1 2.54 x2.32 x1.95 1.00 Non-Penetrating Roof fount Itte,fdr/ f� or Bolted to Buildmq'Meet? PErformancENE (Note:Recommended 1'above roof lino) *- Location? H Yes b pp No 7211 7210-3 XFMR Required sr[ram '" HYes 7210-6 No III ,' tile • PSI 15 -7875 Ground Readily ACI 1 65.9875 cal ACS 460.9125 C Available Extsnne Duplex ■ NW Alarm 46!M125 Roceptacla? i Yes Yes H10AH _ No B AIo 12 AH Power from Panel(Req 1.8A) V — 7707P-88 Fire 8Z Contact Monitoring ONLY 7707-88-ULP Fire 8Z Contact&Dial Capture_ 7007P-M Security 4Z Contact Monitoring ONLY _ 7007P-P-M Security 4Z Contact&Dial Capture MaaS Previously Used Equipment OK_ _ Takeover Existing AES Transceiver ONLY Takeover Existing AES No Transceiver Necessary