Report
OFFICE COPY Commercial Fire Subscriber Submittal Guide \I F cc1 °. bz0zo 4 . �4! rt A } �! f3! l: OFFICE COPY ! Of- i t 'S �i`'.•t a City of Tigard Niche 8720 SW Burnham St Tigard, OR 97223 CITY OF TIGARTI REVIEWED FOR CODE COMPLIANCE Approved: N OTC: j • Permit #: Prepared By: Address: h y PERFORMANCE Suite Date; SYSTEMS INTEGRATION I/ 11......lazzaz 7324 SW Durham Rd Portland, OR 97224 PLEASE PROVIDE info@psintegrated.com COMPLETED NFPA 72 (503) 641-2222 Phone (503) 641-1464 Fax RECORD OF COMPLETION AT FINAL INSPECTION Job #: MON109464 VALIDITY OF PERMIT Date: 10/17/2020 THE ISSUANCE OF A PERMIT BASED ON CONSTRUCTION DOCUMENTS AND OTHER DATA SHALL NOT PREVENT THE CODE OFFICIAL FROM REQUIRING THE CORRECTION OF ERRORS. OSSC 105.4 Scope of Work: Installing new radio for communication Document Index: • Site address map • Fire communicator equipmentlocation • Block Diagram(interface to existing fire alarm system) • System calculations • Wiring diagram • Operations Matrix • Manufacturer's data sheets • AES Build Sheet Site Address Map: ylnc. KEI — —•:: p .:. I 411r. ' ' ' ''' g. ill .=; --- -. I ...: . rr ' — y. 8720, Southwest -- • Burnham Street ty a N. a i 4 ryi,' I Rom,... 113 .. __ ` w fir_ * �,111 Tigard Skatepark - ir s'r. i viit • i 7 iii- 1 , . :ate . 'IA. k.- ,I ' 1 / • I + /'. - • • e mit 'f f f. I f r ._ t i Block Diagram: NEW EQUIPMENT TO REPLACE POTS SYSTEM EXISTING FIRE ALARM SYSTEM(TO REMAIN) (NEW) FIRE FACP TYPICAL NAC OUTPUTS SUBSCRIBER HORNS,STROBES,BELLS... 00 TYPICAL ALARM INPUTS DETECTORS.PULL STATIONS... TYPICAL SUPERVISORY INPUTS DUCT SMOKE DET.,TAMPER SNATCHES... I POT STEM NOTES(CLASS B SYSTEM): O120VAC MAIN POWER FOR THE FIRE ALARM SYSTEM(RE-USE EXISTING(. THIS SYSTEM REQUIRES A DEDICATED CIRCUIT THAT IS LABELED. 'FIRE ALARM CIRCUIT'AND IS ACCESSIBLE ONLY TO AUTHORIZED PERSONNEL. 0 CIRCUIT BREAKER LOCATIONS(SHALL BE PERMANENTLY NOTED AT ALL FIRE ALARM PANELS Battery Calculations: AES 7707 BATTERY CALCULATION WORKSHEET Standby Transmitting Source Description Current Current 7707 MAIN BOARD 0.200 1.200 TOTAL 0.200 1.200 20%Efficiency Factor 1.2 1.2 24 Standby Hour Required Ah Required for Stby 5.760 5 Alarm Minutes Required Ah Required for Alm 0.120 Total Ah required for cabinet 5.880 Battery Capacity Supplied (1)12Ah r Wiring Diagram: Antenna 7791A r ,., Intetera V Reset Sutton © — l n� ENET ( ) )7 SW1 use, use calumet rort- APM ' I+-EONE'prtsnDR OPTS ���—� Ns Comp.., 7880LC2 RI (ICI 0004 Power2 Iles N1Y Transceiver ' ' ' ' ' 115 Ut mud FPI We NOTL One transmver 110 (see NOSE) TrW IX RX WO ALM Sense Reautalea Yapped pHEN product. t Power SuPd7 11 Status InaNltor LEDS 24Y DC DnpuT Antenna FICP Renmxea 24Y DC l(t�a amet LP.4`—I-/— WIRING MUST RE ENCLOSED N CONCEAL O O_ 11+RAT- (see NOTER L 19 C) t Re m E i 7712— Iw0 eua Zone Input Card (((( Rr,A.r11. 7707.01� REFER TO 40 2712 INSTRUCTIONS a^'ry LC0 TOR INSTALIATiON AIC,WIRING Saevrltier Ne:E:q Saner, 111 ZOOC Header Mutt Re J+e.] EAItTN GROVNO CONNECTED B -0—DIPSWI i I IsD TO NIX NUF ON FNCLOSUIIE REFER TO404711 NSTRLCDONS REFER TO R6TRUCTIOP6 FOR FOR INSTALLATION ONO ValPNG. 113 Power DETAIL Owl Option 3 DA., + nu T ZavingRUMFACR IXapwsOE PPNAUX PP�e. DO NOTTpepRNma ._.© CONNECT �' 77Va MUG 17 Outp,n •� 114 N A2-TERMINAL 114 Earth Ground NOMPOARITTrSENSITIVE �J I REFER TO 4D77E7 NSTRUCn0N POWER INPUT + EOM svSTTN CONEIGEwAnONBAT + - COMPpTINE MIME Lin JSANNC J24 4l r y TIWINRli 1 _ _ _ T NOT IMAINTE WIRING MUSTK NO NC C NO NC C E T G V+ 0 0 0 0seem/ MIMED INCONRlUO LJ LJ Power RED swat lE5 option 1 TAIL SECURE FORM OD NOT VAC I REFER 1D 161707 FAIL SECURE IORMC OTINECT ..� + - 220 VAC REFER TO 07 RUE Ttl1077b I 10N7 FOR MM LOAD..74Y DC - + Re[NMlable POWEROPRON NSTPUCTION FOR CONFWS. OTON UNSUPERVISED VISED + 7740 Battery UNSUIfRY5E0 WSTALIATION AND MnueNEiaRor WNW 17 VOW art Teel cell Ivor WING ENCLOSMUSTK NvrE.waHDNI 10•U AI,-CotRRre+Uon Deoer0M NC10SE0 IN OONdIIT. 1140 AMIIMONEXN SEE INSTRUCTIONS FOR BATTERY PEUGM CLASS ROOMER LIMITED TT4WSfORM R E CONMcr2o5[T SIZEREQUOM04N1s SEEmTRUCTIONS FOR APPROVED MOOOS DIKWlb ON ALL CN dN CUITS POWER LIMITED INANSfMER MUST OEENCLOSED IN A6 PEN ID 1610ENCl EXERT BATTEN LEAD& ALL CMCUITS SUPERVTII0 12770IE01130I24 System Configuration Diagram Control Panel Dialer 2 7 7 0 7 Dialer 1 74A fl'�a0 70rr Annunciator 0 77075100104 Fire Alarm Alarm Relay 7707 Control Panel TroubleRelay d ' Local Supervisory Relay ^""'"O"D1 Dialer 2 Dialer 1 7794A • flemola 0 77075100203 Operations Matrix: OUTPUTS cc 2 s � r w Fw z G a < m 2 2 m w x• f m m EXISTING FIRE ALARM SYSTEM F 5 N OPERATIONS MATRIX z a coLid z co m h LL < 0 m w LL = LL = ~O ccF O 2 • U g u Q z z J Z.▪ a w - z J ('J V E 2 2 o z cc a cc 8 m Lj > Z LL I w Q 6 O cc n N 2 I0 I- VI BUILDING FACP(NOT SHOWN)AC POWER LOSS BUILDING FACP(NOT SHOWN)BATTERY POWER LOS FIRE SUBSCRIBER AC FAILURE FIRE SUBSCRIBER CHARGER TROUBLE FIRE SUBSCRIBER LOW BATTERY CONDITION o_ EXISTING FIRE ALARM SYSTEM OPEN CIRCUIT EXISTING FIRE ALARM SYSTEM GROUND FAULT EXISTING FIRE ALARM SYSTEM TROUBLE U EXISTING FIRE ALARM SYSTEM-ALARM EXISTING FIRE ALARM SYSTEM-SUPERVISORY ■.. Manufacturer's Data Sheets&AES Buildsheet: • *AES aes-corp.com 411* ;rSF( ,RI"r) CORPORATION "`' """` ... 7707 Fire Subscribers "l • IntelliNet low z1,• Introducing a Newer, Smarter Alarm Communications Platform _ 8 . a = New Feature .V.:ntet • Leveragesstateofthe arttechnology • Applies advanced security protection • Offers flexible power and configuration options MI 0 • Engineered for backward compatibility with legacy systems NFPA LISTED • Enables future ready capabilities • Provides instant subscriber status through front panel with Power and Trouble LEDs,a backlit LCD display, and Menu/Silence button • Improves functionality with an adaptive Graphic User Interface(GUI)for programming via smartphones,tablet and PCs • Plus many more... Key Benefits that Make 2.0 the Best Alarm Monitoring Solution Ever • Built upon the solid foundation of AES-IntelliNet patented mesh radio technology for use in private licensed wireless networks • Protectssubscriber units against unauthorized access and rogueactivity with a password protected Dealer Code • Makes programming and streamlined troubleshooting easy with user friendly interface • Adds integrated supervision of AES-intelliPro full data module • Provides versatile power options: (1) Direct from the Fire Alarm Control Panel(FACP)without requiring an electrician onsite and without Subscriber backup battery (2) Directly from the FACP with Subscriber backup battery;or (3) Traditional installation with plug in Class 2 low power transformer • Allows for enhancement upgrades and an expanded number of newfeatures to be added easily with highly flexible and scalable alarm communications infrastructure • Rigorously tested to the highest industry standards and future ready to meet emerging NFPA code and UL standards www.aes-corp.com Enhanced Wireless Fire Alarm Monitoring Powered by AES enhanced mesh radio technology, IntelliNet 2.0 7707 Fire Subscribers are next generation universal wireless communicators that provide advanced security protection for any new or existing alarm monitoring network.The AES Model 7707 is ideal for commercial fire applications.With theAES-IntelliPro full data module option,they arethe ideal drop-in replacement for Plain Old Telephone Service(POTS)lines. The red metal enclosure comes with a key lock and front panel LCD backlit display with intuitiveviewthat provides an instant visual of the subscriber status.The user friendly GUI makes iteasyto program AES subscriber units via a smartphone, laptop,tablet,or integrated Universal Serial Bus(USB)—without the need for special cables or having to use a handheld programmer.Additional knockouts make it easier to mount for faster installation. IntelliNet 2.0 Private Wireless Mesh Radio Network D)Burglary ' D Subscriber B 1■■-- a 1M I I a ' U. ' i w ♦ 1 Subscriber ' . I tir 1Lr—• eLSM1.rvv.rP uaa.t.-.ar ty.nm 1 ♦ I eD i B yF ssi =XI -I Pr':mary MS YultNet RecNrer I AlEND EM Alarm 7707 Panel ♦ "I Secondary AES wumet Receiver I gpmiemeigg _ . ®® B t ,♦ ♦ B Alarm Automation •• • I I C A ------ -- - -- C)IP Links Customer Location 1 1.!csh Padio Technology Central Monitoring Station Mu, Gnmary d Secondary AES IduluNet System d lrv•.. cuLng recelestransmisslon in 1.3 seconds The IntelliNet 2.0 Fire Subscriber has an 8 Zone modular design for expansion with normal and reverse polarity, POTS and DACT interfaces with an option for the 7794A AES-lntelliPro full data module add-on accessory board. AES subscribers' intelligent software automaticallydetects new hardware and devicesto reduce installation time. An AES certified WiFi accessory allows seamless wireless connectivity for configuration and programming.A laptop, Ethernet cable,or a Wi-Fi USB dongle is required for IntelliNet 2.0 programming, handheld programmers will not work with 2.0 units. A FACP Power Supply Adapter is required for certain configurations when using flexible power options.The forward compatible design allows for feature add-ons, engineered to adapt seamlessly with future software upgrades as technology advances.IntelliNet 2.0 allows configuration cloning for faster installation time. The AES 7707 was designed with quick configuration and installation in mind to make iteasierforfieldtechnicians to get in, out,and onto the next install. Visit our Fire Marshal Resources web page for official NFPA and UL Listings: http://aes-corp.com/products/fire/fire-marshal-resources/ www.aes-corp.com How to Order 7707 Fire IntelliNet 2.0 Fire Subscribers 2.0 PREMIUM(UL&ULC Listed,Available Now!) 7707P 88 IntelliNet 2.0 Fire Subscriber,8 Zone,8 Supervised Zones,with integrated onboard Local Annunciator, Red Enclosure 7707P-88-ULP IntelliNet 2.0 Fire Subscriber,8 Zone,8 Supervised Zones with 7794A AES-IntelliPro and integrated onboard Local Annunciator, RedEnclosure 7707P-44 IntelliNet 2.0 Fire Subscriber,4 Zone,4 Supervised Zones,with integrated onboard Local Annunciator, Red Enclosure 7707P-44-ULP IntelliNet 2.0 Fire Subscriber,4 Zone,4 Supervised Zones with 7794A AES-IntelliPro and integrated onboard Local Annunciator, Red Enclosure 2.0 FEATURE ADD(Pending UL Review) 7707P-88-M IntelliNet 2.0 Fire Subscriber,8 Zone with Multiple Communication Technologies(MCT), Red Enclosure 7707P-88-ULP-M IntelliNet 2.0 Fire Subscriber,8 Zone with 7794A AES-IntelliPro, and integrated onboard Local Annunciator plus MCT, Red Enclosure 7707P-44-M IntelliNet 2.0 Fire Subscriber,4 Zone with Multiple Communication Technologies (MCT), Red Enclosure 7707P-44-ULP-M IntelliNet 2.0 Fire Subscriber,4 Zone with 7794A AES-IntelliPro, and integrated onboard Local Annunciator plus MCT, Red Enclosure 7707M-UPG IntelliNet2.0 Fire MCT Software Upgrade 2.0 ACCESSORIES 7794A Standalone AES-IntelliPro Fire full data module add-on accessory board with firmware for new IntelliNet 2.0 units only, cannot be used in legacy units 77-WiFi AES certified WiFi adapter 77-FACPA FACP Power Supply Adapter for internal mount 77-FACPA-KIT External installation hardware for 2-waylunction Box Legacy Fire Subscribers 7706-ULF Integrated Fire Monitoring System, Red Enclosure 7788F-ULP-P Legacy Fire Subscriber,8 Zone with 7795 AES-IntelliPro(7794 full data module, 7762 hardware supervisory module, and 7740 Local Annunciator), Red Enclosure 7788E ULP Legacy Fire Subscriber,8 Zone,8 Supervised Zones with 7794 AES-IntelliPro, Red Enclosure 7788F Legacy Fire Subscriber,8 Zone,8 Supervised Zones, Red Enclosure 7744E-ULP-P Legacy Fire Subscriber,4 Zone with 7795 AES-IntelliPro(7794 full data module,7762 hardware supervisory module, and 7740 Local Annunciator), Red Enclosure 7744E-ULP Legacy Fire Subscriber,4x4 Zone,4 Supervised Zones with 7794 AES-IntelliPro, Red Enclosure 7744F Legacy Fire Subscriber,4x4 Zone,4 Reversing Polarity,4 Supervised Zones, Red Enclosure LEGACY ACCESSORIES 7794 Standalone AES-IntelliPro Fire full data module add-on accessory board for legacy units only, please see 7794A above for IntelliNet 2.0 version www.aes-corp.com Technical Specifications 7707 Fire . DIMENSIONS ALARMSIGNALINPUTS/ZONES PORTS 13"H x 8.5"W x 4.5"D • 8 individually programmable Ethernet for configuration and E.O.L. inputsmessagecommunication (33cmH x 21.5cmW x 11.4cmD) type zone USB access for software upgrade • 4+4:4 reverse polarity input and 4 WEIGHT individually programmable E.O.Ltype zone inputs 5.8 lbs(2.6 kilograms) REMOTEANNUNCIATOR excluding battery • Optional 7794A AES-lntelliPro for AES Model 7740 13 lbs(5.9 kilograms)with full data via Contact ID, Pulse, Remote Annunciator,supervised Modem Ile and Modem II1a2 10 Ah battery ULLISTINGS COMPATIBLERECEIVERS R A D I 0 F R E QUE N C Y UL 864 10th Edition 7705i AES-MultiNet Receiver Standard Frequency Range: Standard for Control Units and 450-470 MHz Accessories for Fire Alarm Systems ULC C O N FI GU R A T I O N I N T ER F A CE Contact AES for other UHF and S559-04 1 Edition Equipment for Fire VHF frequencies Signal Receiving Centres and Systems Web browser capable device accessible via smartphone,tablet,laptop,or PC ANTENNA 2.5 dB tamper resistant antenna TROUBLE OUTPUT—ACKDELA CUR RENTCONSUMPTION included,mounts on enclosure Y/ANTENNA CUT Standby w/charged backup battery: Optional remote mounting antenna 200 mA(1.2 A Transmitting) available Form C relay,fail secure,rated 24V DC Standby+charging backup battery:900 1A resistive,unsupervised mA(1.9 A Transmitting-MAX) POWERINPUT RESETBUTTON POWEROUTPUT AC SOURCES Transformer:Class 2 16.5V Located on main circuit board 2et or 5 Watts Factory AC nominal output 1.9 A max current(40 VA MIN)ELK OPERATING TEMPERATURE ELK-TRG1640, EN CL O SU R E M A T ER I A L MG ELECTRONIC SALES MGT1640, 32 to 120°F(0 to 49°C) Steel with paint finish or AES 1640(not included)DC SOURCES(includes FACP) STORAGETEMPERATURE 24V DC Regulated Power Supply FINISHCOLOR with Subscriber 14 to 140°F(-10 to 60°C) Red Rechargeable Battery 1.9 A max current RELATIVE HUMIDITY VI SUALINDICATORS BA C K U P BA TT E R Y 0 to 93%,non-condensing Front panel LCD 10-12 Ah, UL recognized leadacid gel (2sx i 0 alphanumeric character backlit pcell, size based on subscriber R E C HAR G E C AP AB I L I T Y Power and Trouble LEDs configuration Will charge 12V battery size (ALM,Trouble,Tx,Rx,WA) from 10-12 Ah Contact Us For pricing and availability or to learn more about IntelliNet 2.0, please call your local AES Sales Representative at (800) 237-6387 or email sales@aes-corp.com. 00000 www.aes-corp.com AES Corporation I 285 Newbury Street I Peabody,MA 01960 United States 7707 05252017 r • t` e; { . H ice v ...,... .. SLA/A ] II BATTIRIIS Werker SLA technology offers high-density power that out-performs traditional lead acid batteries. The Absorbed Glass Mat(AGM)construction is designed for efficient gas recombination and allows for maintenance-free operation. Werker SLA batteries maintain their high capacity with a design that is resistant to damage caused by deep discharge. Every Werker SLA battery is inspected to ensure the highest standards in materials and fabrication. Battery Features: Charger Features: • Werker SLA AGM batteries contain a proprietary grid alloy New! SLA Chargers formula.This formula combined with the advanced plate curing techniques offer improved performance. • Regulated trickle charge for"float"mode charging • Werker batteries contain a unique electrolyte formula with a • Short circuit protected special sub-colloid additive for higher reliability and longer life. • Reverse polarity protected • More than 1,000 discharge/recharge cycles. • Thermal protection in case of overload • The unique construction and sealing techniques of the Werker • Alligator clips battery guarantee leak-proof operation. • Color LED to indicate state of charger • Heavy-duty lead calcium tin alloy grids provide an extra margin of performance and service life in cyclic applications,even after repeated over-discharges. • Quality Assurance Engineers monitor and control the entire • production process. We r k e -= o) �e• eot9oi SUltafilill BATTERIES Flame Capacity Dimensions Haight Over Weight Flame Capacity Dimensions Height Over Weight hem* Vohs Retardant Ah LxWxHlin.) Terminallin.) Iles.) Item Volts Retardant Ah LKWxHhn) Terminal lin.) ills.) 12 - 0.8 3.78x 0.98x 2.40 2.4 0.8 12 - 7.5 5.94x2.56 x3.74 3.98 6.0 12 - 1.3 3.82x1.69x2.05 2.28 1.4 12 - 12 5.94x3.90 x3.74 3.98 9.3 12 - 2 5.91 x0.79x3.54 3.54 1.7 12 - 18 7.13x3.03 x6.57 6.57 13.9 uuxA 12 - 23 6.97 x 1.38 x 2.40 2.64 2.0 x,vA,12 12 - 26 6.50 x 6.93 x 4.92 4.92 20.3 12 - 3.2 5.28x 2.64x2.40 2.84 3.2 12 - 35 7.72x5.16 x6.10 6.57 25.4 WKAl2 i 31- WKAl2 izrz 12 - 4.5 5.51 4 1.89 x 3.98 4.21 4.4 12 - 35 7.72 x 5.16 x6.10 7.09 25.4 WKA72-25r 12 - 5 3.54x2.7643.98 4.21 4.0 wxAi214noi 12 Y 45 7.80x6.54x6.85 6.85 357 ry M1X,z-zee 12 - 7e 5.94x2.56x3.74 3.98 6.0 12 Y 60 9.02x5.43 x8.19 8.35 40.3 vV M1X1G-3.J� rvr�Xll-3��. WKAl2-5 lA WKAl2-33J Continued on Next Page WKAl2-5E WKAl2-44C1FR F4gmeterinformation please contact: WKAl2-55uFa Re a iacementD[PP ., . r .co Re 'ore the Power for LESS' www.ReplacementUPSbattery.com Phone: 952-217-6611 Email: info@replacementupsbattery.com ContinuedfromPrevlousPege Pagel SLA/AGM BATTERIES Flame Capacity Dimensions Lx Height Over Weight Flame Capacity Dimensions la Height Over Weight Hem# Volts Retardant Ah WxH(In.1 Terminal(in.! [lbs.! Hem# yob Retardant Ah WaH(In.! Terminal(In.1 (Ibs.I WKAl2-559/FR 12 Y 60 9.02 x5.43 x8.19 9.06 40.3 WKA6-14A 6 14 4.25 x2.80 x5.51 5.51 6.2 WKAl2.80C/FR 12 V B0 10.24 x 6.65 x8.31 8.46 55.1 WKA6-14T1 6 14 4.25 42.80 x5.51 5.51 6.2 WKAl2-801VR 12 V B0 10.24 x 6.65 x8.31 9.06 55.1 WKAG-14T2 6 14 4.25 x2.80 25.51 5.51 6.2 WKAl2-1000/FR 12 V 100 12.09 x6.65 x8.31 8.46 72.8 WKA6-14T3 6 14 4.25 x 2.80x5.51 5.51 6.2 WKAl2-1001/FR 12 Y 100 12.09 x6.65 3831 9.06 72.8 WK56-42F2 6 42 6.38 03.4626.42 6.69 15.9 WKAl2-126/FR 12 y 140 13.43 x 381x 11.06 11.3 104.7 WKA6-4258 6 42 6.38 x 3.46 x6.42 6.85 15.9 WKA6-1.3F 1.3 3.82 x0.94 x2.05 2.28 0.7 WKA4-4.5F2 4 4.5 1.85 x1.85 x3.98 4.21 1.3 WKA6-3.3F 3.2 5.28 x1.34 x2.40 2.64 1.6 WKA6-5F 5 2.76 x1.85 x3.98 4.21 2.1 WERKER SLA CHARGERS WKA6.55P 5 2.64 x2.64x3.82 4.53 2.0 Dimensions Lac Weight WKA6-7.2F 7.2 5.94 x 1.343.74 3.98 3.0 Hem# Volts mA WxH(in.l (lbs.! WKA6-B.2F 8.2 3.9022.24 x4.53 4.53 3.8 WK6V500 6V 50OnA 2.36 x2.04 x.73 0.58 WKA6-10F 10 5.94 x1.97 23.74 3.98 4.4 WK12VS00 12V 500mA 2.36 x2.04 x.73 0.66 WKA6-11F 12 5.94 x L97 x3.74 3.98 4.6 WK6VI000 6V I000mA 2.54 22.32 21.95 0.86 WKA6-12F2 12 5.94 31.97 x3.74 3.98 4.6 WK12V1000 1210 1000mA 2.5482.3281.95 1.00 ROTPenetrntlnq Root Mount -- ' or Bolted to 8mlamq'Mast' PErformancE (Note:Recommended o 4' boveovc roof Onui Smoke 160M Loaedon4 HYes No 13 i , 7211 72 0-3 YeXFs Required swan �7210-6 No . ,, . ▪ O II PSI g 7875 Ground Readily '▪ $ • ACI `65.9875 CAI '"' • ACS 460.9125 AV a i l a b l e ...mom 111 NW Alarm 46g,125 Ilmowtsele Yes _ Yes — 10 AH _ No e 1, 0 12 AH Power from Panel(Req 1.8A) 7707P-88 Fire 8Z Contact Monitoring ONLY— _ 7707-88-ULP Fire 8Z Contact&Dial Capture _ 7007P-M Security 4Z Contact Monitoring ONLY 7007P-P-M Security 4Z Contact&Dial Capture MaaS Previously Used Equipment OK Takeover Existing AES Transceiver ONLY_ Takeover Existing AES No Transceiver Necessary