Report OFFICE COPY Commercial Fire Subscriber Submittal Guide City of Tigard Public Works 8777 SW Burnham St Tigard, OR 97223 PLEA.;:. ,0".771 COMPL -:. ';I~ 'A 72 COI , <.: . . -.T FINAL i't l :.?F C I ION OFFICE COPY CITY OF TIGARfl, REVIEWED FOR CODE COMPLIANCE Prepared By: Approved: ) OTC: ) ) PERFORMANCE • Pcrmit#: jp.5ac p — 1)Q f 1 ) SYSTEMS INTEGRATION Address: 8.777 nukylin J-+ 73245W Durham Rd Suite #: Portland, OR 97224 By: ` Date: 0- !Van info@psintegrated.com (503) 641-2222 Phone (503) 641-1464 Fax VALIDITY OF PERMIT THE ISSUANCE OF A PERMIT Job#: MON109462 BASED ON CONSTRUCTION Date: 10/17/2020 DOCUMENTS AND OTHER DATA SHALL NOT PREVENT THE CODE OFFICIAL FROM REQUIRING THE CORRECTION OF ERRORS. OSSC 105.4 Scope of Work: Installing new radio for communication Document Index: • Site address map • Fire communicator equipmentlocation • Block Diagram (interface to existing fire alarm system) • System calculations • Wiring diagram • Operations Matrix • Manufacturer's data sheets • AES Build Sheet Site Address Map: , Ti ard Water Ditrict't, - 1-es, - .1 * . . . ,.... .,. .4'.3 ... - w , • -p- ... . ,.. 4`,1,4 .. . .., ..;„ • - • ' i' , '-5,.. s;9. '- ir,„ ‘. "'(‘Cfd-, 4"ir‘4,-'• Tigard Public Works . --, w. - -t . he Mattress Guy r , Mattress stoFe`,,,, - , -- • \ • FinishingR ilk ilk , SW BUtn133.:159t1:1_ , \ ' ' • , . . f *T ,..` . —7- ' t .e 0-e.44•-• •. . ... P., .-- i 6 1 Ill Mat; .......t.... ,•,1 • 4,11 I • : :4‹,•6: . e , "••' 1111 `..._ 1 ‘ '.' \ • ^, • Block Diagram: NEW EQUIPMENT TO REPLACE POTS SYSTEM EXISTING FIRE ALARM SYSTEM(TO REMAIN) (NEW) FIRE FACP TYPICAL NAC OUTPUTS SUBSCRIBER - HORNS,STROBES,BELLS... O© TYPICAL ALARM INPUTS DETECTORS,PULL STATIONS... TYPICAL SUPERVISORY INPUTS DUCT SMOKE DET.,TAMPER SWITCHES... I POT STEM NOTES(CLASS B SYSTEM): O120VAC MAIN POWER FOR THE FIRE ALARM SYSTEM(RE-USE EXISTINGI. THIS SYSTEM REQUIRES A DEDICATED CIRCUR THAT IS LABELED. "FIRE ALARM CIRCUIT"AND IS ACCESSIBLE ONLY TO AUTHORIZED PERSONNEL. Co CIRCUIT BREAKER LOCATIONS)SHALL BE PERMANENTLY NOTED AT ALL FIRE ALARM PANELS Battery Calculations: AES 7707 BATTERY CALCULATION WORKSHEET Standby Transmitting Source Description Current Current 7707 MAIN BOARD 0.200 1.200 TOTAL 0.200 1.200 20%Efficiency Factor 1.2 1.2 24 Standby Hour Required Ah Required for Stby 5.760 5 Alarm Minutes Required Ah Required for Alm 0.12C Total Ah required for cabinet 5.880 Battery Capacity Supplied (1)12Ah Wiring Diagram: Antenna 7794A Irl.rlfao a/' Relit IM OD c n� O ENET (6) 17 9F us& use MEMO von- APM H f^Conn!Oration Porn ProgrammingPOWer ' a,Al,.orpra•. 0 62 7880LC2 72 iAelNv Transceiver • ' • • • 115 IAusled t,PT NOTE:One lrannoyer 110 (see NOT11 Tall TX RR Wo AIM Sedce 'hyped NIIN I%ndV(1 t IMEARIPower ply IiiA S atus IndNator LEDs 7av a Grout Antenna EACR At0 red 114 201�itARTT NA 1 WIRING MVSIIL ENCLOSED N CONDUIT. li{ MT- MOTE'(.ee OTEI ,.Y 19 O 0 las F 7712— Noll TRACK Zeno Input Card • 'ah.le.tle 7710°4 REFER TO 407212 NIS11WCT0NS I Embry tco FOR MEM LOON Aro1MRNG Subaalbtr REFIRE.Dann 111 Zone Header Kew:De and EARTH GROUND CONNECTEE r• IP$Wl I 1 10 MEOW COINCLOYM1 8 f-D REFER roa ntiNSTNXiBONs leD REFER TO N6TRDCTICIVS FOR FOR INSTALLATION ANDVARNG. 111 Power OMR. ni°Slr.' r oN Option - o+N,u r— 7111 Q /O,WICpul Card In•:F ONrIaViF hrl Y_I[For ['se�.. r� NO 24V MC u M. _ COO NNECT l.ma .r CBV41S__ 114TS A7TERMINA/ 114 Earth Ground NON MAW),SENSITIVE R 1 REFER To 4T m1 NSTNKnon a J, _ FOR sn*TTACONnwRAnON tDMwnelE mra LIST 15 ANNC 124 BAT - 11116V/24V /r TERMINAIs D.N.r a _ ... ss N01 W5flGMusrER NO NC C NO NC C E T G V+ O O 7 O O sL F NEI OMIT IN EMMET Power L J RED lIACK Ms Option THOME- ILA` DO NOT I�}t� �c uovAt REaRroaa77Gr TAIL SECURE fORMC CONNECT •-—1' 4 - FI REAP 10 0.1707 MAX MD 24VDC RIF(R10 al740 , a RlrJurEabl! ONO iNSTR70Wlt TlCNS I A MAXT RIS11DVE NSTFN2CT10raS FOR 7740 Battery '- CONTRAMAtON INSTALLATION ANO AnnunE}atpr IMURERR15F0 WININGMVSTe WINNG. 10a111*-.ad C q uWH2ro ENCLOSED IN CONO1111. IlDTE'W I LftE0 SEE10•IN FRU CvNS POR B IVE RAdlrR R240 NOINOATOR SEE INSTRURION510R BATTERY FLOG IN nAS52PPlILR ELMIrED LR4N5101tMER CONNECTED SF WI REOU IRE AIR NTS SCENSTRUC TONS COP REPROVED MODELS DIKY(1b ONALI CIRCUITS POWER LIMITED TRANSFORMER Mutt rt ENCLOSED IN MS r/N 40 1(10ENCI. MEET RATTKRO LEADS. ALL CIRCUITS SVNRVet D DET137E0150174 System Configuration Diagram Control Panel Dialer 2 7 7 0 7 Dialer 1 77saA I I a. 0 77075100104 Fire Alarm Alarm Relay 7707 Control Panel TroubleRelay R Local Supervisory Relay Mnunramr Dialer 2 Dialer 1 7794A • Remolo am,nditrlr 077075100203 Operations Matrix: OUTPUTS z co z co X I— I" 2 4/1 2 z G 2 LU Z Z CO U.! U O co co m EXISTING FIRE ALARM SYSTEM 1- g N OPERATIONS MATRIX ? a z z v, — u LL LL = sr. N C H O CC = Z N Q tn z 5 a z J V' 6 2 m Z 0 0 K 7 co 2 F u IZ O 6 Q m LU 0 V m 5 LL• _ L W Q C 9, 2• Q F fn BUILDING FACP(NOT SHOWN)AC POWER LOSS BUILDING FACP(NOT SHOWN)BATTERY POWER LOS _ FIRE SUBSCRIBER AC FAILURE FIRE SUBSCRIBER CHARGER TROUBLE FIRE SUBSCRIBER LOW BATTERY CONDITION I- 0- Z EXISTING FIRE ALARM SYSTEM OPEN CIRCUIT EXISTING FIRE ALARM SYSTEM GROUND FAULT EXISTING FIRE ALARM SYSTEM TROUBLE EXISTING FIRE ALARM SYSTEM-ALARM EXISTING FIRE ALARM SYSTEM-SUPERVISORY Manufacturer's Data Sheets &AES Buildsheet: aes-corp.com 411* .. r( IIRITI CORPORATION "` """ 7707 Fire Subscribers ,„„ 410 IntelliNet 2 .0 �Tp 4. Introducing a Newer, Smarter0 Alarm Communications Platform e New Feature Highlights • Leverages state ofthearttechnology • Applies advanced security protection • Offers flexible power and configuration options ; 0 • Engineered for backward compatibility with legacy systems NFPA LISTED >, • Enables future ready capabilities • Provides instant subscriber status through front panel with Power and Trouble LEDs,a backlit LCD display, and Menu/Silence button • Improves functionality with an adaptive Graphic User Interface(GUI)for programming via smartphones,tablet and PCs • Plus many more... Key Benefits that Make 2.0 the Best Alarm Monitoring Solution Ever • Built upon the solid foundation of AES-!nte/hNet patented mesh radio technologyfor use in private licensed wireless networks • Protects subscriber units against unauthorized access and rogue activity with a password protected Dealer Code • Makes programming and streamlined troubleshooting easy with user friendly interface • Adds integrated supervision of AES-IntelliPro full data module • Provides versatile power options: (1) Direct from the Fire Alarm Control Panel(FACP)without requiring an electrician onsite and without Subscriber backup battery (2) Directly from the FACP with Subscriber backup battery;or (3) Traditional installation with plug in Class 2 low power transformer • Allows for enhancement upgrades and an expanded number of newfeatures to be added easily with highly flexible and scalable alarm communications infrastructure • Rigorously tested to the highest industry standards and future ready to meet emerging NFPA code and UL standards www.aes-corp.com , Enhanced Wireless Fire Alarm Monitoring Powered by AES enhanced mesh radio technology, Internet 2.0 7707 Fire Subscribers are next generation universal wireless communicators that provide advanced security protection for any new or existing alarm monitoring network.The AES Model 7707 is ideal for commercial fire applications.With the AES-IntelliPro full data module option,they are the ideal drop-in replacement for Plain Old Telephone Service(POTS)lines. The red metal enclosure comes with a key lock and front panel LCD backlit display with intuitiveviewthat provides an instant visual of the subscriber status.The user friendly GUI makes it easy to program AES subscriber units via a smartphone, laptop,tablet,or integrated Universal Serial Bus(USB)—without the need for special cables or having to use a handheld programmer.Additional knockouts make it easier to mount for faster installation. IntelliNet 2.0 Private Wireless Mesh Radio Network DI Burglary D'''''h,,, SubscriberIns •,,,,, , , C N B)Fire , , \ ! . .4 Subscriber '' usv.n tT .,or.ara... ..rtnrr. • r _ �� ^�ul B Primary MS-NUIrINee PrcNve( BIB A)Alarm 7707 Panel If 'I S..00e..y MS-YWrw R. w ee .ee. I • .- --� B l .� B 777 I C Alarm Automation a• • - - --- A �-__-__--- -_ -El C)IP links Customer Location Mesh Radio Technology Central Monitoring Station .'t.path AL ' .-''.Nett Netwcc Primary&Sccouuary as i.t • -.-alarm.. ..smart fouling e[eves r,ansmissiOn rn' The IntelliNet 2.0 Fire Subscriber has an 8 Zone modular design for expansion with normal and reverse polarity, POTS and DACT interfaces with an option for the 7794A AES-IntelliPro full data module add-on accessory board. AES subscribers' intelligentsoftwareautomaticallydetects new hardware and devicesto reduce installationtime. An AES certified WiFi accessory allows seamless wireless connectivity for configuration and programming.A laptop, Ethernet cable,or a Wi-Fi USB dongle is required for IntelliNet 2.0 programming, handheld programmers will not work with 2.0 units. A FACP Power Supply Adapter is required for certain configurations when using flexible power options.The forward compatible design allows for feature add-ons, engineered to adapt seamlessly with future software upgrades as technology advances. IntelliNet 2.0 allows configuration cloning for faster installation time. The AES 7707 was designed with quick configuration and installation in mind to make it easierfor field technicians to get in, out,and onto the next install. Visit our Fire Marshal Resources web page for official NFPA and UL Listings: http://aes-corp.com/products/fire/fire-marshal-resources/ www.aes-corp.com How to Order 7707 Fire IntelliNet 2.0 Fire Subscribers 2.0 PREMIUM(UL&ULC Listed,Available Now!) 7707P 88 IntelliNet 2.0 Fire Subscriber,8 Zone,8 Supervised Zones,with integrated onboard Local Annunciator,Red Enclosure 7707P 88 ULP IntelliNet2.0 Fire Subscriber,8 Zone,8 Supervised Zones with 7794AAES-IntelliPro and integrated onboard Local Annunciator, Red Enclosure 7707P-44 IntelliNet 2.0 Fire Subscriber,4 Zone,4 Supervised Zones,with integrated onboard Local Annunciator,Red Enclosure 7707P-44-ULP IntelliNet 2.0 Fire Subscriber,4 Zone,4 Supervised Zones with 7794A AES-lnte!IiPro and integrated onboard Local Annunciator, Red Enclosure 2.0 FEATURE ADD(Pending UL Review) 7707P-88-M IntelliNet 2.0 Fire Subscriber,8 Zone with Multiple Communication Technologies(MCI), Red Enclosure IntelliNet 2.0 Fire Subscriber,8 Zone with 7794A AES-IntelliPro,and integrated 7707P-88-ULP-M onboard Local Annunciator plus MCT, Red Enclosure 7707P-44-M IntelliNet 2.0 Fire Subscriber,4 Zone with Multiple Communication Technologies(MCT), Red Enclosure 7707P-44-ULP-M IntelliNet 2.0 Fire Subscriber,4 Zone with 7794A AES-IntelliPro,and integrated onboard Local Annunciator plus MCT, Red Enclosure 7707M-UPG IntelliNet 2.0 Fire MCT Software Upgrade 2.0 ACCESSORIES 7794A Standalone AES-IntelliPro Fire full data module add-on accessory board with firmware for new IntelliNet 2.0 units only,cannot be used in legacy units 77-WiFi AES certified WiFi adapter 77-FACPA FACP Power Supply Adapter for internal mount 77-FACPA-KIT External installation hardware for 2-wayJunction Box Legacy Fire Subscribers 7706-ULF Integrated Fire Monitoring System, Red Enclosure 7788F-ULP-P Legacy Fire Subscriber,8 Zone with 7795 AES-IntelliPro(7794 full data module,7762 hardware supervisory module,and 7740 Local Annunciator), Red Enclosure 7788F-ULP Legacy Fire Subscriber,8 Zone,8 Supervised Zones with 7794 AES-IntelliPro,Red Enclosure 7788F Legacy Fire Subscriber,8 Zone,8 Supervised Zones,Red Enclosure 7744E-ULP-P Legacy Fire Subscriber,4 Zone with 7795 AES-IntelliPro(7794 full data module,7762 hardware supervisory module,and 7740 Local Annunciator), Red Enclosure 7744E-ULP Legacy Fire Subscriber,4x4 Zone,4 Supervised Zones with 7794 AES-IntelliPro,Red Enclosure 7744F Legacy Fire Subscriber,4x4 Zone,4 Reversing Polarity,4Supervised Zones, Red Enclosure LEGACY ACCESSORIES 7794 Standalone AES-IntelliPro Fire full data module add-on accessory board for legacy units only, please see 7794A above for IntelliNet 2.0 version www.aes-corp.com 1 Technical Specifications 7707 Fire - DIMENSIONS ALARM SIGNAL INPUTS/ZONES PORTS 13"H x 8.5"W x 4.5"D • 8 individually programmable Ethernet for configuration and message co rn m u n i catio n (33cmH x 21.5cmW x 11.4cmD) E.O.L.type zone inputs USB access for software upgrade • 4+4:4 reverse polarity input and 4 WEIGHT individually programmable E.O.L. pe zone inputs REMOTEANNUNCIATOR 5.8lbs(2.6 kilograms) AES Model 7740 excluding battery • Optional 7794A AES-InteliPro for 13 lbs(5.9 kilograms)with full data via Contact ID, Pulse, p Remote Annunciator,supervised Modem Ile and Modem 111a2 10 Ah battery ULLISTINGS COMPATIBLERECEIVERS RADIO F R E QUE N C Y UL 864 10th Edition 7705i AES-MultiNet Receiver Standard Frequency Range: Standard for Control Units and I 450-470 MHz Accessories for Fire Alarm Systems ULC Contact AES for other UHF and 5559-04 1st Edition Equipment for Fire CONFIGURATION I N T ER F A CE VHF frequencies Signal Receiving Centres and Systems Web browser capable device accessible I via smartphone,tablet,laptop,or PC ANTENNA 2.5 dB tamper resistant antenna TROUBLE OUTPUT—ACKDELA CURRENT CONSUMPTION included,mounts on enclosure y/gryTENNA CUT Standby w/charged backup battery: Optional remote mounting antenna 200 mA(1.2 A Transmitting) available Form C relay,fail secure,rated 24V DC Standby+charging backup battery:900 1A resistive,unsupervised mA(1.9 A Transmitting-MAX) POWER INPUT AC SOURCES RESETBUTTON POWEROUTPUT Transformer:Class 2 16.5V Located on main circuit board 2 or 5 Watts Factory AC nominal output set 1.9 A max current(40 VA MIN)ELK OPERATING TEMPERATURE ELK-TRG1640, ENCLOSUREMATERIAL MG ELECTRONIC SALES MGT1640, 32 to 120°F(0 to 49°C) Steel with paint finish or AES 1640(not included)DC SOURCES(includes FACP) STORAGETEMPERATURE 24V DC Regulated Power Supply FINISH COLOR with Subscriber 14 to 140°F(-10 to 60°C) Red Rechargeable Battery 1.9 A max current RELATIVE H U MID ITY VISUAL INDICATORS BA C K U P BA T T E R Y 0 to 93%,non-condensing Front panel LCD (210-12 Ah, UL recognized leadacid gel disx Ia0 alphanumeric character backlit cell, size based on subscriber R E C HAR G EC AP AB I L I T Y Power and Trouble LEDs configuration Will charge 12V battery size (ALM,Trouble,Tx,Rx,WA) from 10-12 Ah Contact Us For pricing and availability or to learn more about inte11iNet 2.0, please call your local AES Sales Representative at (800) 237-6387 or email sales@aes-corp.com. © 0000 www.aes-corp.com AESCorporation 1285NewburyStreet I Peabody,MA01960United States 7707 05252017 F r ,i SLqJ '.• BATTERIES Werker SLA technology offers high-density power that out-performs traditional lead acid batteries. The Absorbed Glass Mat(AGM)construction is designed for efficient gas recombination and allows for maintenance-free operation. Werker SLA batteries maintain their high capacity with a design that is resistant to damage caused by deep discharge. Every Werker SLA battery is inspected to ensure the highest standards in materials and fabrication. Battery Features: Charger Features: • Werker SLA AGM batteries contain a proprietary grid alloy New! SLA Chargers formula.This formula combined with the advanced plate curing techniques offer improved performance. • Regulated trickle charge for"float"mode charging • Werker batteries contain a unique electrolyte formula with a • Short circuit protected special sub-colloid additive for higher reliability and longer life. • Reverse polarity protected • More than 1,000 discharge/recharge cycles. • Thermal protection in case of overload • The unique construction and sealing techniques of the Werker • Alligator clips battery guarantee leak-proof operation. • Color LED to indicate state of charger • Heavy-duty lead calcium tin alloy grids provide an extra margin of performance and service life in cyclic applications,even after repeated over-discharges. • Quality Assurance Engineers monitor and control the entire • production process. We r k e re (soot) s• SLA/AGM BATTERIES Flame Capacity Dimensions Height Over Weight Flame Capacity Dimensions Height Over Weight Item I Volts Retardant Ah L x W a H tin.) Tannins!(in.) (Ibs.) Item a Volts Retardant Ab L x W a H(in.) Terminal(in.) (Dud 12 - 0.8 3.78x 0.98x2.40 2.4 0.8 12 - 7.5 5.94x2.56x3.74 3.98 6.0 12 - 1.3 3.82 x 1.69 x 2.05 2.28 1.4 12 - 12 5.94 x 3.90 x 3.74 3.98 9.3 12 - 2 5.91 x0.79x3.54 3.54 1.7 12 - 18 7.13x3.03x6.57 6.57 13.9 ,..,.1,oKM. 12 - 2.3 6.97x1.38x2.40 2.64 2.0 wrl,lTs=2 12 - 26 6.50 x 6.93 x 4.92 4.92 20.3 12 - 3,2 5.28 x2.64x2.40 2.64 3.2 12 - 35 7.72x5.16x6.10 6.57 25.4 wxn121.3r WKn12121-2 12 - 4.5 5.51 x 1.89 x 3.98 4.21 4.4 12 - 35 7.72x5.16x6.10 7.09 25.4 WKA1225T WKA121UHDL 12 - 5 3.54 x2.76 x 3.98 4.21 40 12 Y 45 7.80x6.54x6.85 6.85 35.7 Wr,.,.2-2.6r 12 - 7.5 5.94x2.56x3.74 3.98 6.0 ^"^•2-2.ne 12 Y 60 9.02x5.43x8.19 8.35 40.3 Wnnu-3.3r Wf,au-331. WKAl2 S.1A W KAl2-33J Continued on Next Page WKAl2-5F WKAl2-44CIFR FgmoRFinfonnation please contact: WKAl2-SsuFR Re . lacementUIP�am .,ogflqin Restore the Power for LESS!:, www.ReplacementUPSbattery.com Phone: 952-217-6611 Email: info@replacementupsbattery.com e Continuedfrom PreviousPege Page2 SLA/AGM BATTERIES Flame Capacity dmemions Lx Height Over Weight Flame Capacity Dimensions Lx Height Over Weight Rem# Volts Relardam Ah WxH(in.1 Terminal(in.l (Ibs.l Item# Volts Retardant Ah WxH(in.I Terminal(in.l (Ibs.l WKAl2-55P/FR 12 y 60 9.02 x5.43 x8.19 9.06 40.3 'd1KA6-14A 6 14 4.25 x2.80 x 5.51 5.51 6.2 WKAl2-80C/FR 12 5 B0 10.24 x6.65 x 8.31 8.46 55.1 WtA6.14T1 6 14 4,25 x2.80 x 5.51 5.51 6.2 WK412-801P11 12 Y 80 10.24 x 6.65 x 8.31 9.06 55.1 W4A6-14T2 6 14 4.25 x2.80 x5.51 5.51 6.2 WK412-1000/FR 12 Y 100 12.09 x 6,65 x 8.31 8.46 72.8 WKA6-1413 6 14 4.25 x 2.80 x 5.51 5.51 6.2 WK812-1118/FR 12 Y 100 12.09 x 6.65 x8.31 9.06 72.8 WKA6-42F2 6 42 6.38 53.46 x6.42 6.69 15.9 WKAl2-125196 12 Y 140 13.43x 6.81x 11.06 11.3 104.7 WKA6-4266 42 6.38 x3.46 x 6.42 6.85 15.9 WKA6-1.3F 1.3 3.82 x0.94 x2.05 2.28 0.7 WKA4-4.5F2 4.5 1.85 x1.85 x3.98 4.21 1.3 WKA6-3.3F 3.2 5.28 x1.34 x2.40 2.64 1.6 WKA6-5F 5 2.76)(1.85 x3.98 4.21 2.1 WERKERSLA CHARGERS WKA6-55P 5 2.64 x2.64 x3.82 4.53 2.0 DhrtlNlom Lx Weight WKA6-7.2F 7.2 5.94 x 13,43.74 3.98 3.0 Volts MA WxH(ln.l (Ibs.l WKA6-B.2F 8.2 3.90 x2.24 x4.53 4.53 3.8 WK6V500 64 500mA 2.36 x2.04 x.73 0.58 WKA6-10F 10 5.94 x1.97 x3.74 3.98 4.4 WK12V500 12V 500mA 2.36 x2.048.73 0.66 WKA6-129 12 5.94 x1.97 63.74 3.98 4.6 WK6V1000 6V 1000mA 2.54 x2.32 81.95 0.86 WKA6-12F2 12 5.94 x1.97 x3.74 3.98 4.6 WK12V1000 12V 10005rA 2.540.320.95 1.00 • r Non-Penotrnttng Root Mount or Bolted to Butlding'Mora? (Note:Recommended PErformanc€:Ne; 4'obovo roof lino) Sm 6:113 ro Above oke LocatronT H iL) YNoes 7211 72010-3 XFMR Required Strntr' 721 -6 Yes 6dt No III N ih, nob 1 ■ PSI CE50111 Ground Readily • ACI C17131 cm II ACS 460.9125 Available et1te11Ra llilglea El NW Alarm 461n1125 Yes MeeeBYMeT r Yes _ 10AH No No 12 AliPower from Panel(Req 1.8A) _ 7707P-88 Fire 8Z Contact Monitoring ONLY ... 7707-88-ULP Fire 8Z Contact&Dial Capture 7007P-M Security 4Z Contact Monitoring ONLY _ 7007P-P-M Security 4Z Contact&Dial Capture _ MaaS Previously Used Equipment OK Takeover Existing AES Transceiver ONLY Takeover Existing AES No Transceiver Necessary