Loading...
Permit n,04 CITY OF TIGARD FIRE PROTECTION SYSTEM PERMIT • III:, COMMUNITY DEVELOPMENT Permit#: FPS2020-00123 T ARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 12/1/2020 4; Parcel: 2S112AB00400 Jurisdiction: Tigard Site address: 7500 SW LANDMARK LN Project: Spec Space Subdivision: None Lot: None Project Description: Fire sprinkler permit:Adding(7)sprinkler heads. Affidavit submitted. Contractor: AFP SYSTEMS INC Owner: LANDMARK LANE LLC 19435 SW 129TH AVE ATTN GLENN HAYTER TUALATIN, OR 97062 23643 SW STAFFORD HILLS DR WEST LINN, OR 97068 PHONE: 503-692-9284 PHONE: FAX: 503-692-1186 FEES Description Date Amount Specifics: Permit Fee-COM 11/30/2020 $72.61 12%State Surcharge-Building 11/30/2020 $8.71 Type of Use: COM Plan Review-Fire Life Safety-COM 11/30/2020 $29.04 Class of Work: ALT Type of Const: Info Process/Archiving-Sm$0.50(up to 11/30/2020 $0.50 Occupancy Grp: Height: ft 11x17) Stories: Commercial Sprinkler System: Sprinkler Required: Yes Sprinkler Type: Wet Standpipe Required: No Hazard: LT Density: .1 Design Area: 1500 K Factor: 5.6 Commercial Fire Alarm System: Fire Alarm Required: Alarm Type: Pull Station Required: Smoke Detectors Req: Battery Calcs Provided: Cut Sheets Required: Total $110.86 Valuations: Required Items and Reports(Conditions) Sprinkler Valuation: $1,300.00 Residential Square Footage: 0 Fire Alarm Valuation: $0.00 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions tt000►�OU(NC by ccaallinng'5503..2332'j19987 or 1.800.332.2344. c� 1[�� Issued By: k'"" ""�7 1J " - Permittee Signature: � a,(e1 tai V l �!J Call 503.639.4175 by 7:00 a.m.for the next available inspection date. ` i This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Building Permit Applic CEI /ED 11 I IS 1� Fire Protection System y V C FOR OFFICE USE ONLY Cityofa Tigard NOV 1 V 2020 Received 1514/0 Permit No.: ]3125 SW Hall Blvd.,Tigard, $ ��3C Dale By: 125 ��� — g � 1CDale By: yf/ Other Permit: Phone: 503.718.2439 Fax: SB3cI98.L9glyr TIGARD iV TIGARD Inspection Line: 503.639.41DU ILD I NG DIVISION Dale Ready/By: ./JUl t�1June: See Page for Internet: www.tigard-or.gov Notified/Method: !/14,2 4 t T( Supplemental Information Eirtc,itte( N t TYPE OF WORK REQUI•.. D DATA:I-AND 2-FAMILY DWELLING ❑ New construction ❑Demolition Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all ® Addition/alteration/replacement ❑Other: equipment,materials,labor,overhead,and the profit for the CATEGORY OF CONSTRUCTION work indicated on this application. ElI-and 2-family dwelling ®Commercial/industrial Valuation: $ ❑Accessory building ❑Multi-family Number of bedrooms: ❑Master builder ❑Other: Number of bathrooms: JOB SITE INFORMATION AND LOCATION Total number of floors: Job site address:7500 SW Landmark Lane New dwelling area: square feet City/State/ZIP:Tigard,OR 97224 Garage/carport area: square feet Suite/bldg./apt.no.: Project name:Landmark Lane'II Covered porch area: square feet Cross street/directions to job site: Deck area: square feet Other structure area: square feet REQUIRED DATA:COMMERCIAL-USE CHECKLIST Subdivision: Lot no.: Permit fees*are based on the value of the work performed. Tax map/parcel no.: Indicate the value(rounded to the nearest dollar)of all equipment,materials,labor,overhead,and the profit for the DESCRIPTION OF WORK work indicated on this application. Add 7 sprinkler head drops off of existing wet system to cover new floor plan Valuation: $$1300.00 Existing building area: square feet New building area: square feet ❑ PROPERTY OWNER ❑ TENANT Number of stories: Name: Type of construction: II-B Address: Occupancy groups: City/State/ZIP: Existing: B,S-1,F-1 Phone:( ) Fax:( ) New: no change ® APPLICANT Fj CONTACT PERSON NOTICE Business name:AFP Systems Inc. All contractors and subcontractors are required to be Contact name:Raedyn Silva licensed with the Oregon Construction Contractors Board under ORS 701 and may be required to be licensed in the Address:19435 SW 129th Ave jurisdiction in which work is being performed.If the City/State/ZIP:Tualatin,OR 97062 applicant is exempt from licensing,the following reasons apply: Phone:(503)692-9284 Fax: :(503)692-1186 E-mail:raedyn@afpsys.com CONTRACTOR BUILDING PERMIT FEES' Business name:AFP Systems Inc. (Please refer le fee schedulej Permit fee: Address: 19435 SW 129t6 Ave City/State/ZIP:Tualatin,OR 97062 State surcharge(12%of permit fee): FLS plan review(40%of permit fee): Phone:(503)692-9284 Fax:(503)692-1186 (Due upon application submittal.) CCB lic.:67534 Total permit fees: Authorized signature: Amount received: This permit application expires if a permit is not obtained Print name:Steve Frost Date: 11/17/2020 within 180 days after it has been accepted as complete. * Fee methodology set by Tri-County Building Industry Service Board. 1:�aulaing\PermitsTPS-PermitApp_071514.doe 440-4613T(I INvroM/WEB) City of Tigard: Fire Protection Permit Checklist Page 2- Supplemental Information Describe work to be done: 1.) Type of Work: 2.) Addition/alteration only to sprinkler heads: 3.) Addition/alteration only to alarm devices: ❑ New system Number of sprinkler heads: 7 Number of alarm devices: ® Addition or ® 1-10 heads: Affidavit required and ❑ 1-5 devices: Affidavit required and Alteration (3) copies of sketch showing area (3) copies of sketch showing area to existing of work within building structure of work within building structure system ❑ i l+ heads: Plan review required and ❑ 6+ devices: Plan review required and (3) sets of plans. (3) sets of plans. Additional description of work: Type of System (Complete A, B, C or D as applicable): A.) Commercial Sprinkler ® Wet ❑ Dry Additional Standpipes Information: Hazard Group LH Density 0.10 Design Area 1500 K. Factor 5.6 Sprinkler Project Valuation: $ 1,300.00 B.) Type I - Hood Fire Suppression System Hood Project Valuation: $ C.) Fire Alarm Submittal shall Battery Calculations ❑ Yes include: Individual Component ❑ Yes Cut Sheets Fire Alarm Project Valuation: $ D.) Residential Sprinkler(Stand Alone System) Square Footage: Permit Fee: 0 to 2,000 $198.75 2,001 to 3,600 $246.45 3,601 to 7,200 $310.05 7,201 and greater $404.39 Sprinkler Project Square Footage: sq. ft. Fire Protection Permit Fees Project valuation subtotal (see A,B&C above): $ 1,300.00 Permit fee based on project valuation (see fee schedule): $ Permit fee based on square footage (sec D above): $ State Surcharge (12%of permit fee): $ FLS Plan Review(40% of permit fee): $ TOTAL: $ X:\Pemuts Steve new\Tigard\landmark lane TI FPS_PenmtApp.doc 2 Branden Taggart From: #Building Permit Technicians Sent: Wednesday, November 25, 2020 6:23 PM To: 'raedyn@afpsys.com' Subject: RE: Landmark Lane Permit: FPS2020-00123 -7500 SW Landmark Lane - New Submittal Attachments: Invoice.pdf Hi Raedyn, The sprinkler permit for Landmark Lane is ready to issue now. The balance due is$110.86, and I have attached an invoice above for you to reference. The permit fees can be paid online through our website: https://aca.accela.com/tigard/Default.aspx. From there, click on the Building tab, enter the permit number (FPS2020-00123) in the Record Number field, and click Search. Once paid, please notify us at TigardBuildingPermitsr7a tigard-or.gov, and I will email the permit paperwork to you. Thanks, Branden Taggart ® City of Tigard IIIII I 3 :>, Senior Permit Technician Community Development 13125 SW Ball Blvd Tigard, OR 97223 (5031718-2449 bra ndent w tig and-o r.gov From:#Building Permit Technicians Sent: Wednesday, November 18, 2020 1:53 PM To: raedyn@afpsys.com Subject: Landmark Lane TI -7500 SW Landmark Lane- New Submittal Hi Raedyn, Thank you for your recent permit submittal. This submittal has met the requirements needed to begin review. We will contact you for payment,if applicable, or when the permit is ready to issue. Please allow 2-4 weeks for processing. Tina Escalera Permit Tech Assistant City of Tigard I Community Development 13125 SW Hall Blvd.Tigard, OR 97223 1 City of Tigard Permit No.: i'j ,f?j) J-W -3 . . • 13125 SW Hall Blvd.,Tigard,OR 97223 Phone: 503.718.2439 Fax: 503.598.1960 Date Received: _/_��� III . Inspection Line: 503.639.4175 T 1 `"\K I' Internet: www.tigard-or.gov By: At! i sed CC PRI KLER AFFIDAVIT FORO1a EC E I V E D FIRE S ALTERAT N OR TENANT IMPROVEMENTS NOV 18 2020 (1 to 10 SPRINKLER HEADS WITHOUT PLANS) CITY OF TIGARD BUILDING DIVISION Project Name: Landmark Lane TI Occupancy: B-office Job Address: 7500 SW Landmark Lane, Tigard, OR 97224 Type of Construction: II-B Suite: Contractor: AFP Systems Phone: 503-692-9284 Number of Proposed or Altered Heads: 7 l vpe: wet Hazard: light Density: 0.10 1, Steve Frost/AFP Systems Oregon Construction Contractors Board No. 67534 certify the following is true and reasonably defines the scope of work for this project: a) All work is limited to drops and armovers in a light-hazard occupancy. b) Positions of sprinkler heads relative to architectural features such as soffits, beams, partitions,walls, etc. complies with current adopted edition of NFPA 13. c) The proposed work does not require hydraulic calculations. d) Only one sprinkler head will be installed from one drop(exception: up to two heads from one drop may be installed when each head is in a separate fire area). e) The area covered per sprinkler head is limited to the spacing requirements of NFPA 13. f) Tenant improvements in a new building shall be equipped with Quick Response heads(see 2002 NFPA 13, Section 8.3.3.1 for exceptions). g) The installation shall comply with the requirements of the current adopted edition of NPFA 13. h) Piping shall not be concealed until hangers and bracing are inspected. i) Final approval shall be subject to onsite tests and inspections. In addition, I understand the following is required: • Submit(3) copies of a sketch showing the area of work within the building's structure. • Building fire protection system permit. • A copy of this docu ent ith a copy of the sketch attached shall be available for all inspections. Signature: Dale: 11/17/2020 Print Name: Steve Frost 1:ABuildin_AForms\FireSprinklerAffidavit 071514.docx Pagg I of I