Plans RADON MITIGATION SYSTEMS
VILLAGE AT WASHINGTON SQUARE NORTH
11157 SW HALL BLVD
BUILDING C TIGARD, OR 97223
1st FLOOR
I
KITCH BATH
LIV RM
UNIT Cl IO
ENTRY
LEGEND:
ENTRY 0 RADON THRU-FLOOR SUCTION POINT
KITCH AND VERTICAL SCHDL-40 PVC VENT PIPE.
BATH SEE SCHEMATIC.
LIV RM BED
UNIT C2
I
SLEEPING
LAUNDRY
BED BATH
LIV RM BED
ILEGEND:
�0 0 RADON VERTICAL VENT PIPE
SCHDL-40 PVC
UNIT C3 - - SEE SCHEMATIC
KITCH
BED
BATH
ENTRY 0
BUILDING C
2nd FLOOR
SCALE: I in"
Product Information
Firestop Collar
(CP 643N) 1
Product description •
�;E A ready-to-use firestop collar, made of a galvanized steel housing
and intumescent inserts for firestopping combustible pipes
T
Product features ♦�
Ready-to-use collar
r. :' if
No construction required .
Fast installation time
Adjustable mounting tabs '�
Low profile for tight installations
Areas of application
Firestopping combustible pipes up to 6"diameter in penetrations Technical Data CP 643N
through fire walls and floors Pipe Collar Collar No.of
Suitable for the following pipe materials: outside outside Height hooks and
PVC,CPVC,ABS,PVDF,PP and FRPP Description dia(In.) dia.(in.) (in.) fasteners
For use with CP 643-50/1.5"N 1.4-2.0 2.8 0.9 2
Concrete,masonry,wood floor and gypsum wall assemblies CP 643-63/2"N 2.0-2.5 3.4 1.3 2
Wall and floor assemblies rated up to 4 hours CP 643-90/3"N 2.6-3.6 4.9 1.7 3
CP643-110/4"N 3.6-4.5 6.0 1.9 3
Types of installation CP 643-160/6"N 6.6 9.8 1.9 4
Wall:two collars,one on each side Temperature resistance -40°F to 140°F(-40°C to 60°C)
Floor.one collar on underside(bottom) Intumescent activation Approx.392°F(200°C)
Example Expansion ratio(unrestricted) Up to 1:10
Waste water pipes Tested in accordance with
Fresh water pipes •UL 1479 •ASTM E 814 •ASTM G21ri
••ip_ IN •
ThROP H-PEN ® EI
4\/•`Tu•'/V/ FOR USE IF1 hIROUGH-PE DEVICE
V V
FIRESTOP SYSTEMS °'••-"�•"""••'
C isSEE UL FIRE RESISTANCE DIRECTORY APPROVED Mai MAyatw,mlaiOdo win.
5N78 FEC.,is a trademark at
the wanxai concretion.
Installation instructions for CP 643N
Notice Application of firestop system 5. Fastening the CP 643N Firestop Collar. Only when
• Before handling,read Material Safety Data Sheet and 2. Seal the opening if required.Gaps may be closed fastened properly can CP 643N offer protection
product label for safe usage and health information. with FS-ONE.The approved methods vary and are against fire.
• Instructions below are general guidelines—always given in the specific UL system. a. Mark the fastening points.
refer to the applicable drawing in the UL Fire 3. Close the CP 643N Firestop Collar.Place the b. Drill holes with a Hilti rotary hammer drill(i.e.
Resistance Directory or Hilti Firestop Systems Guide CP 643N Firestop Collar around the plastic pipe TE 4-A18)or,depending on base material,fasten
for complete installation information and lock the closure by applying firm pressure until using Hilti powder-actuated tool.
It latches.Opening c. To secure the CP 643N Firestop Collar,use HMI
1. Clean the plastic pipes.Expansion of the 4. Attach fastening hooks.The fastening hooks can anchors/fasteners.
bintumescent material during a fire acts to close the attached to various points on the metal housing. d. For maintenance reasons,a penetration can be
pipe.Verydirtypipes(le: This allows the fastening points to be made to suit
plastic with remains of the space available in each case.The hooks must permanently marked with an identification plate and
mortar)may lead to a delay in this closing action. bepositioned as symmetrically as fastened in a visible position next to the seal.
Soiled plastic pipes should,therefore,be cleaned in Y Y possible.The
the area where the CP 643N Firestop Collar is to be required number of fastening hooks is indicated on Not for use
installed, the packaging. • With metal pipes
• In highly corrosive surroundings
4� tzz �� • With unapproved anchors fasteners
• • I. �Wlit Storage
1� �� • Store only in the original packaging in a location
fir IM
'�� ' protected from moisture
1.Clean plastic pipe. 2.Close remaining gap to 3.Claw collar. 4.Attach fastening hooks. 5.Fasten collar and
provide smoke and gas identification plate
resistant seat (it required).
„ I-1.,
<.- HIM'Firestop
Saving lives
y through innovation
...
and education
Hilti. Outperform. Outlast.
Hilti,Inc.(U.S.)1-800-879-8000•www.us.hilti.com•en espanol 1-800-879-5000•Hilti Firestop Systems Guide
_ . .
Installation and Operation Manual
-... Manuel d'installation et d'operation
_..
._.
Rn2EC i RnilEC
lniine EC Radon Fan • Ventlateur pour radon en ligne EC
PARTS IN THE 130 Ilin2ECI PAWS IN THE BSA:Ar4ECI
PILES DANS LA RITE IRr2ECI PIECES WINS LA ROM IRn4ECI
C Eh.) f jr ill it _
US 1 CEFITIFIED
t
1111
RAM Rail
z bli
PECHTER"THIS PPO:l20-70 M El
INCREASE YOUR PRODJ:37 - c. r• a
WARRANry' '•inv AN EX-7;A ' AP ;MI • min .
I .
.r.
-ealstrv. TL_IJArAg_Q.'1_ _;.., :. 2 -:01
Technical/Customer Support: :V7:: fantech®
.......1::::
United States-e' KY:-4" ' LT Canada'd ..:::::::z,-.2.,
a systemay-