Loading...
Permit CITY OF TIGARD MASTER PERMIT COMMUNITY DEVELOPMENT Permit#: MST2020-00145 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 10/27/2020 T I i;A II D Parcel: 2S107AA09200 Jurisdiction: Tigard Site address: 14400 SW GOLD COAST TER Subdivision: ROSHAK RIDGE Lot: 92 Project: Polygon at Roshak Ridge-Lot 92 Project Description: New SFA BUILDING Floor Areas Required Setbacks Required Stories: 3 Bedrooms: 3 First: 65 sf Basement: 0 sf Left: 0 Parking Spaces: 0 Height: 35 Bathrooms: 3 Second: 684 sf Garage: 606 sf Front: 8 Smoke Dwelling Units: 1 Third: 672 sf Right: 0 Detectors: Yes Total: 1421 sf Value: $208,030.12 Rear: 5 PLUMBING Sinks: 1 Water Closets: 3 Washing Mach: 1 Laundry Trays: 0 Rain Drain: 1 Urinals: 0 Lavatories: 4 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain 0 Storm Sewer: 100 Tubs/Showers: 2 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Drains: Catch Basins: 0 Bckfw Prevntr: 0 Footing Drain: 0 Ice Maker: 1 Hose Bib: 2 Backwater Value: 1 Other Fixtures: 0 Drywall-Trench Drain: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: Y Vent Fans: 4 Clothes Dryers: 1 Natural Gas Heat Pump: N Hoods: 1 Other Units: 0 Fum<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 3 Fum>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add''500 sf: 3 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Other: N Other Description: Ecompasing: Y BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: NEW SFA VB R-3 1421 Owner: Contractor: POLYGON WLH LLC POLYGON WLH,LLC Required Items and Reports(Conditions) 703 BROADWAY ST STE 510 703 BROADWAY STREET,SUITE 510 1 Ersn Cntrl 503-639-4175 VANCOUVER,WA 98660 VANCOUVER,WA 98660 PHONE: PHONE: 360-695-7700 FAX: 360-693-4442 Total Fees: $26,608.03 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. Issued By: \`I63VQr•N. WC- Permittee Signature: O(\ o►pp11C.R0nd''.\ Call 503.E 9.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the Job site at the time of each inspection. ,,3/20 . eivb & 9z Building Permit Application • LoT Residential • RECEIVED ' FOR OFFICE USE ONLY Received 05-0 2020 MST2020-001145 1111 - City of Tigard FEB C 3 2020 ?emit DateB p�/� 13125 SW Hall Blvd.,Tigard,OR 97223 Plan Review � SWsl LULL-M Phone: 503.718.2439 Fax: 503.598.19tQ(T\(OF TIGARD DateB : ,/O 26 i Alm Other R �0UU013 TIGARD Inspection Line: 503.639.4175 BUILDING DIVISION Date Ready/By: .Arms: RISee Paget for Internet: www.tigard-or.gov xotified/Metbod:-) / 'fil Supplemental Information TYPE OF WORK REQUIRED DATA:1-AND 2-FAMILY DWELLING ®New construction ❑Demolition Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all 0 Addition/alteration/replacement ❑Other: equipment,materials,labor,overhead,and the profit for the CATEGORY OF CONSTRUCTION work indicated on this application. ® 1-and 2-family dwelling 0 Commercialindustrial Valuation: $ ;?6 D3© ❑Accessory building ❑Multi-family Number of bedrooms: ��j ❑Master builder • 0 Other: Number of bathrooms: �+,g� JOB SITE INFORMATION AND LOCATION Total num. Z ors:/3� 2 OW/ S Job site address: OD God eJ�- Tx a. New dwe .?area: - square feet t.el la' g � q � D14 City/State/ZIP:Tigard, 97224 Gaza e c a: square feet Suite/bldg./apt no.: Project name:Roshak Ridge Covered porch area: square feet j Cross street/directions to job site: Deck area: L 2... square feet Ol} earea:, k.r a•Z square feet REQ D DATA:�COMMERCIAL-USE CHECKLIST Subdivision:Roshak Ridge Lot no.: C 2- Permit fees*are based on the value of the work performed. Tax map/parcel no.: (if equipment, the value(rounded to the nearest dollar)of all equipment,materials,labor,overhead,and the profit for the DESCRIPTION OF WORK work indicated on this application. Valuation: $ Existing building area: square feet New building area: square feet ® PROPERTY OWNER ❑ TENANT Number of stories: Name:Polygon WLH,LLC Type of construction: Address:703 Broadway St.,Ste 510 Occupancy groups: City/State/ZIP:Vancouver WA 98660 Existing: Phone:(360)695-7700 Fax:( ) New: ® APPLICANT ❑ CONTACT PERSON BUILDING PERMIT FEES* Business name:Polygon WLH,LLC (Please refer to fee schedule) Structural plan review fee(or deposit): lI Contact name:Tonja Morris FLS plan review fee(if applicable): Address:703 Broadway St.,Ste 510 City/State/ZIP:Vancouver WA 98660 Total fees due upon application: Phone:(360)695-7700 Fax::( ) Amount received: E-mail:permitsubmmittais@polygonhomes.com PHOTOVOLTAIC SOLAR PANEL SYSTEM FEES* Commercial and residential prescriptive installation of CONTRACTOR roof-top mounted PhotoVoltaic Solar Panel System. Business name:Polygon WLH,LLC Submit two(2)sets of roof plan with connection details and fire department access,along with the 2010 Oregon Address:703 Broadway St.,Ste 510 Solar Installation Specialty Code checklist. City/State/Z1P:Vancouver WA 98660 Permit Fee(includes plan review $180.00 and administrative fees): Phone:(360)695-7700 Fax:(360)693-4442 State surcharge(12%of permit fee): $21.60 CCB lic.:204238 Total fee due upon application $201.60 Authorized signature: ` This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. Print name:Tonja Morris Date:04/17/2019 *Fee methodology set by Tri-County Building Industry S Service Board. T.\Rnildino\Permits\RT TP-RRSPermitAnn tine 02/24/2011 440f16131(1 i/02JCOM .,B7 . Mechanical Permit Application FOR OFFICE USE ONLY Received I vl t�T- 0 0-001 City of Tigard C `` Y Permit No. of �,/LV _ ' 13125rSWHal Blvd.,Tigard,OR 972RECEI V EDPlan Review y: Other Peamt. Phone: 503.7I8.2439 Fax: 503.598.1960 FEBqq Date/By: _ r Inspection Line: 503.639.4175 FEB C 20 L0 Date Read B Iurer 0 See Page 2 for II,:'v?s ltli Y Y 8 Internet: www.tigard-or.gov Notified/Method: Supplemental Information CITY OF TIGARD TYPE OF vRl D1NG DIVISION 1 COMMERCIAL FEE" SCHEDULE USE CHECKLIST Mechanical permit fees*are based on the value of the work ®New construction ❑Addition/alteration/replacement performed.Indicate the value(rounded to the nearest dollar)of all ❑Demolition ❑Other: mechanical materials,equipment,labor,overhead,and profit. Value:$ CATEGORY OF CONS I RUCTION - RESIDENTIAL EQUIPMENT/SYSTEMS FEES* tgi 1-and 2-family dwelling ❑Commercial/industrial ❑Accessory building For special information use checklist I Multi-family ❑Master builder ❑Other: Description Qty. Ea. Total JOB SITE rINFORMATION .4ND LOCATION Heating/cooling: . - Air conditioning 46.75 Job site address: I L{ +OC) C-1 ot- GDR 5 T \-- 1- Furnace 100,000 BTU(ducts/vents) 46.75 City/State/ZIP:Tigard,OR 97224 Furnace 100,000+BTU(ducts/vents) 54.91 Heat pump 61.06 Suite/bldg./apt.no.: Project name:Roshak Ridge Duct work 23.32 Cross street/directions to job site: Hydronic hot water system 23.32 Residential boiler(radiator or hydronic) 23.32 Unit heaters(fuel-type,not electric), in-wall,in-duct,suspended,etc. 46.75 Flue/vent for any of above 23.32 Subdivision:Roshak Ridge Lot no.: cf.2i Other. 23.32 Other fuel appliances: Tax map/parcel no.: Water heater 23.32 DESCRIPTION OF,WORK Gas fireplace/insert 33.39 Flue vent for water heater or gas fireplace 23.32 Log lighter(gas) 23.32 Wood/pellet stove 33.39 Wood fireplace/insert 23.32 Chimney/liner/flue/vent 23.32 Other: 23.32 ® PROPERTY OWNER ❑ TENANT Environmental exhaust and ventilation: Name:Polygon WLH,LLC Range hood/other kitchen equipment 33.39 Address:703 Broadway St.,Ste.510 Clothes dryer exhaust 33.39 City/State/ZIP:Vancouver,WA 98660 Single-duct exhaust(bathrooms, toilet compartments,utility rooms) 23.32 Phone:(360)695-7700 Fax:( ) Attic/crawlspace fans 23.32 ® APPLICANT El CONTACT PERSON Other: 23.32 Business name:Polygon WLH,LLC Fuel piping: $14.15 for first four;$4.03 for each additional Contact name:Tonja Morris Furnace,etc. Address:703 Broadway St.,Ste 510 Gas heat pump Wall/suspended/unit heater City/State/ZIP:Vancouver,WA 98660 Water heater Phone:(360)695-7700 Fax::(360)693-4442 Fireplace Range E-mail::permitsubmittais@polygonhomes.com Barbecue CONTRACTOR Clothes dryer(gas) Business name:Pro Heating&Cooling Other: MECHANICAL PERMIT FEES" Address: NW Alociek Dr,Ste.1104 Subtotal City/State/ZIP:Hillsboro,OR Minimum permit fee($90.00) Plan review(25%of permit fee) Phone:(360)270-1590 Fax:( ) Stare surcharge(12%of permit fee) CCB lie.:209001 TOTAL PERMIT FEE t� This permit application expires if a permit is not obtained within 180 f,J ^udays after it has been accepted as e Authorized signature: (�WGL ` Fee methodology set by Tri-County Building Industry Service Board Print name:Elia Duran Date:04/08/2019 I Building\Permits\MEC Permitpp_010113.doe 440-46I 7T(l 1/02/COM/WEB) 4. Electrical Permit Application ;� f F cusrk�� City of Tigard RECEIVES « � �■0 {"`6 ` Received Permit M UI f-✓W _�"I 1�/ € Y hp a 13125 SW Hall Blvd.,Tigard,OR 97223 Plan Review E^ I4. Phone: 503.718.2439 Fax: 503.598.196t-EB C 3 20/0 DatelBy: Related Permit#: ' Inspection Line: 503.639.4175 Ready Date/By: ram: RI See Page 2 for TIGARD Internet: www.tigard-or.gov CITY OF TIGARD Notified/Method: Supplemental Information TirPE OF DI G DIAS,1°N 4'_ r- Yie ,Ai.- li*W-.:.a_-' ®New construction IDAddition/alteration/replacement 'Please check all that apply(submit 2 sets of plans w/items checked): 0 Service or feeder 400 amps or more 0 Building over three stories. I:Demolition ❑Other: where the available fault current 0 Marinas and boatyards. ' .. .t.:CAT,EGORY._OF:CONSTRUCTION ,r:J ':.:_: exceeds 10,000 amps at 150 volts or 0 Floating buildings. ® 1-and 2-family dwelling ❑Commercialindustrial ❑Accessory building less to ground or exceeds 14,000 0 Commercial-use agricultural amps for all other installations. buildings. ❑Multi-family 0 Master builder 0 Other. ❑Fire pump, 0 Installation of 150 KVA or r JOB SITE•:INF'ORMYIATION'AND'I)CATION : ." ❑Emergencysystem. larger separately derived Job#: Job site address: L(k'- O C-t e 5- ' 1jj!. 0 Addition new motor load of system. ��• 100HP or more. ❑"A" "E' "i-2""1-3" Ci /State/ZiP:Ti err OR 97224 ❑Six or more residential units. occupancy g d' ❑Health-rue facilities. ❑Recreational vehicle parks. Suite/bldg./apt.#: _ Project name:Polygon At Roshak Ridge 0 Hazardous locations. 0 Supply voltage for more than ❑Service or feeder 600 amps or more. 600 volts nominal Cross street/directions to job site: FEE SCB EI)TILE " Description I Qty. I Eu I Total j h * New residential single-or multi-family dwelling unit. Subdivision:Polygon at Roshak Ridge Lot#: OI'L Includes attached garage. 1,000 sq.11.or less 168.54 4 Tax map/parcel#: Ea add'I 500 sq.ft.or portion 33.92 1 DESCRIPTION OF WORK Limited energy,residential (with above sq.ft.) 75.00 2 Limited energy,multi-family 75.00 2 residential(with above sq.ft.) Renewable Energy ❑"See Page 2 ®.PROPERTY;OWNER•':.`. . 0 TENANT. Services or feeders installation alteration,and/or relocation Name:William Lyon Homes,Inc. 200 amps or less 100.70 2 Address:703 Broadway St Suite 510 201 amps to 400 amps 133.56 2 401 amps to 600 amps 200-34 2 City/State/ZIP:Vancouver,WA 98660 601 amps to 1,000 amps 301.04 2 Phone:(360)695-7700 Fax:(360)693-4442 Over 1,000 amps or volts 55226 2 Temporary services or feeders installation,alteration,and/or Email: relocation • Owner installation:This installation is being made on property that I own which is not 200 amps or less 1 59.36 1 intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 201 amps to 400 amps 125.08 2 Owner signature: • Date: 401 amps to 599 amps 168.54 2 ® APPLICANT ❑ CONTACT PERSON Branch circuits—new,alteration,or extension,per panel A Fee for branch circuits with Business name:William Lyon Homes,Inc. above service or feeder fee, 7.42 2 each branch circuit Contact name:Nichole Thorpe • B.Fee for branch circuits without Address:703 Broadway St Suite 510 service circi feederfee,first 56.18 2 City/State/ZIP:Vancouver,WA 98660 Each add'I branch circuit 7.42 2 Miscellaneous(service or feeder not included) Phone:(360)695-7700 Fax::(360)693-4442 Each manufactured or modular 67.84 2 dwelling,service and/or feeder Email:permitsubmittals@polygonhomes.com Reconnect only 67.84 2 CONTRACTOR Pump or irrigation circle 67.84 2 Business name:Alameda Electric Sign or outline lighting 67.84 2 Address:3415 NE 44th Signalnle circuit(s)o or extension. ❑ See Page 2 2 panel,alteration,or extension City/State/ZIP:Portland OR 97213 Each additional inspection over allowable in any of the above Additional inspection(1 he min) 6625/br Phone:(503)319-2192 Fax:( ) Investigation(1 hrmin) 90.00/hr Email:solarpdx@me.com • Industrialplaat(1 hrmin) 78.18/hr Inspections for which no fee is 90.00/hr CCB Lic.: 199188 Electrical Lie.: c923 Suprv.Lic.: 48715 specifically listed(h br min) ELECTRICAL PERMIT FEES Suprv.Electrician signature,required: Subtotal Print name: Rile Rood Date: 03/08/2019 0 Plan Review Required(25%of permit fee): • ¢ State surcharge(12%of permit fee): _Authorized signature: J � TOTAL PERMIT FEE: / This permit application expires if a permit is not obtained Within 180 Print name: Kile Rood Date: 03/08/2019 days after it has been accepted as complete. ' * Number of m section allowed per permit. I3lumbin2 Permit Application Building Fixtures RECEIVE i FOR OFFICE USE ONLY Received No.M&f2O2O_Ks/�� City of Tigard Receive Permit VVt�/ IIIq 13125 SW Hall Blvd.,Tigard,OR 97223 FEB ,� Z Q j Q Plan Review Phone: 503.718.2439 Fax: 503.598.1960 Date/By: OF TiGARD Other Permit No.: TIGARD Inspection Line: 503.639.4175 CITYDate Ready/By: 7uriv: El See Page 2 for Internet: www.tigard-or.gov - ' Notified/Method: Supplemental Information TYPE OF WORK FEE* SCHEDULE ®New construction ❑Demolition For special information use checklist Description ( Qty. Ea. I Total ❑Addition/alteration/replacement ❑Other: New 1-2-family dwellings(includes 100 ft.for each utility connection) CATEGORY OF CONSTRUCTION SFR(I)bath 312.70 ❑ 1-and 2-family dwelling ❑Commercial/industrial SFR(2)bath 437.78 0 Accessory building ID Multi-family SFR(3)bath 500.32 Each additional bath/kitchen 25.02 ❑Master builder ❑Other: Fire sprinkler( sq.ft.) Page 2 JOB SITE INFORMATION AND LOCATION ; .--- ,.: Site utilities: Job site address: ,1'klk� ex,,,, W1�s- -tom, Catch basin or area drain 18.76 City/State/ZIP:Tigard,OR 97224 Drywall,leach line,or[tench drain 18.76 Footing drain(no.linear ft.:_) Page 2 Suite/bldg./apt.no.: Project name:Roshak Ridge Manufactured home utilities 50.03 Cross street/directions to job site: Manholes 18.76 Rain drain connector 18.76 ' Sanitary sewer(no.linear ft.:_) Page 2 Storm sewer(no.linear IL:_) Page 2 Water service(no.linear ft.:_) Page 2 Subdivision:Roshak Ridge I Lot no.: c,i„ Fixture or item: Tax map/parcel no.: Backflow preventer 31.27 DESCRIPTION OF WORK Backwater valve 12.51 `� 1�l' �� � �` Clothes washer 25.02 Dishwasher 25.02 Drinking fountain 25.02 Ejectors/sump 25.02 El PROPERTY OWNER, I ❑ TENANT Expansion tank 12.51 Name:Polygon WLH,LLC Fixture/sewer cap 25.02 Floor drain/floor sink/hub 25.02 Address:703 Broadway St.,Ste 510 Garbage disposal 25.02 City/State/ZIP:Vancouver,WA 98660 Hose bib 25.02 Phone:(360)695-7700 Fax:( ) Ice maker 12.51 ® APPLICANT ❑ CONTACT PERSON Interceptor/grease trap 25.02 Business name:Polygon WLH,LLC Medical gas(value:$ ) Page 2 Primer 12.51 Contact name:Tonja Morris Roof drain(commercial) 12.51 Address:703 Broadway St.,Ste 510 Sink/basin/lavatory 25.02 City/State/ZIP:Vancouver,WA 98660 Solar units(potable water) 62.54 Phone:(360)695-7700 Fax::(360)693-4442 Tub/shower/shower pan 12.51 E-mail:permitsubmittals@polygonhomes.com Urinal 25.02 CONTRACTOR Water closet 25.02 Water heater 37.52 Business name: Alliance Plumbing Water piping DWV 56.29 Address: 146 W Historic Columbia River Hwy Other. 25.02 City/State/ZIP:Troutdale,OR 97060 Subtotal Phone:(503)492-3490 Fax:(503)912-6438 Minimum permit fee: $72.50 CCB Lic.:184601 Plumbing Lie,no.:PB732 Plan review (25%of permit fee) State surcharge(12%of permit fee) Authorized signature: TOTAL PERMIT FEE Print name:Robert.Dishman Date: This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. *Fee methodology set by Tri-County Building Industry Service Board. i:1BuildiegsPermitsTLMU-PermitApp.doc 10/01/09 440-4616T(10/02/COM/WEB) City of Tigard n COMMUNITY DEVELOPMENT DEPARTMENT C .. T1cARD Building Permit Review — Residential m, Building Permit #: M ST2D20-00145 Site Address: J4/L/ 0 -c)/(-) a/J a,,c-4 ---7--,d,-.26e Project Name: aP�NA 77 d?--f— / , "/ -e_ Lot #: C?. Planning Review Ci Pro• •sal: i/l,() Q In Verify address/suite# active in Accela. Fil In River Te .ce: ❑ No Yes,River Terrace Review Addendum Sit: 'Ian Elements: 4 Erosion Control 3...copies of site plan on 8-1/2"x 11"or 11 x 17"paper 'VP,' -tained trees with drip line and tree protection measures VD awn to scale (standard architect or engineer scale) otprint of new structure (including decks)and FFE G ► .rth arrow 1 -ty locations&easements(required for new and additions) VA, ite address,project or subdivision name and lot number f►Sidewalk/driveway approach Pig plicant information(name and phone number) U 11, anon of wells/septic systems dimensions and building setback dimensions S eet tree size,type and location uare footage of buildings to be demolished IIQS tet names sting structures on site 1QComer elevations (2'contours if more than 4'differ tial) t area,building coverage area,percentage of coverage and >1,000 sf of impervious area created or replac:.? IV'Yes ❑N impervious area(applicable if R-7,R-12,R-25&R-40) If -es,is a storm water •uali facili shown j ,ii'' ■Yes To yr 1 Ill* Clean Water Services-Service Provider Lett (lot platted prior to 9/10/1995): Required: ❑ Yes,applicant was notified No Received: ❑ Yes ❑ No ktYWater Meter Fixture Unit Worksheet-Addis,Remodels and ADUs Required: ❑ Yes,applicant was notified .i No ,,,,/ Received: ID Yes ❑ No 11� C Exemption for ADU applied for: ❑ Yes ld No Received: ❑ Yes ❑ No 7 Public FacilitiV. Improvement(PFI) Permit: quired: V Yes,applicant was notified ❑ No Alied For: Yes ❑ No,stop intake and Use Case#: ii620t c- OO lld�j oning. &k quired Setbacks: Front: 0 Rear: / Side: U Street Side: 10/fr Garage: l�. s- ding Height Max. Height: /0/ }- Actual Hei ht:_ SC.— Landscape Area: —2C2 % ❑ Lot Coverage Max: % Entrance et back no more than 8'from street-facing wall ❑ Parallel to et or offset 45 degrees or less Windows ❑ Minim %of area of all street-facing facades iK Garage ❑ Garage door is be . idest street-facing wall ‘•-) Yes 0 No,one of the following is met: ❑ Door extends no more 'from wall ere is a covered porch extending beyond garage. ❑ Door extends no more than 5' and there is a 12 sq ft.window above garage on 2"d floor. ❑ Garage door width is ❑ ' r less ❑ 50%o of facade ❑ 60%or less and includes 7 of following: ❑ Covered po Recessed entrance 0 Wall o s 0 1'Roof eave ❑ Roof offset ❑ Fir • gles ❑ Lap Siding ❑ Roof pitch ❑ Gable, ' , ambrel roof 0 Dormer Accent siding Window trim ❑ Window recess ❑ Window - ction ❑ Balcony II a Visual Clearance Urban Forestry n 111) nsitive Lands: ❑ Yes L� No Type: Conditions met prior to issuance of building permit No s: \ Approved By Planning: = L^ Date: JO ,2. Revisions (after Building Submittal only) Reviewer Date Revision 1: ❑ Approved ❑ Not Approved Revision 2: ❑ Approved ❑ Not Approved I:\Building\Forms\BldgPermitRvw_RES_I22419.docx J Building Permit Submittal Original Submittal Date: Q,z-r 3-2020 Site Plans: # Building Plans: # Building Permit#: []'Enter building permit#above. Workflow Routing: [a-Planning M.-Engineering arfermit Coordinator l-Building Workflow Sign-off: [Sign-off for Planning(include notes from planning review) Route Application Documents: E'Engineering: (1) copy of permit application, (1) site plan, (1) building plan and original plan review routing form. ©'Building: original permit application, site plans,building plans,engineer and beam calculations and st details,if applicable, etc. Notes: By Permit Technician: Date: 5$-$ 2O2.0 En i'neering Review S pe at building pad: 1_04 L /Conditions "Met"prior to issuance of building permit �l/`z' [ Easements (encroachments) per engineering conditions of approval and plat Water Quality/Quantity Facility: ,�/ Assess Water Quality Fee in-lieu: 0 Yes l(�' No Assess Water Quantity Fee in-lieu: ❑ Yes [VNo �� LIDA Facility on lot: 0 Yes Leto la" Final Plat Recorded: 0 NOT Approved by Engineering: Date: Notes:Approved by Engineering: _ Date: _S-7///2G Revisions (after Building Submittal only) / Reviewer Date Revision 1: 0 Approved 0 Not Approved Revision 2: 0 Approved 0 Not Approved Permit Coordinator Review Conditions "Met"prior to issuance of building permit ❑ Approved, NOT Released: Date: Notes: Revisions (after Building Submittal only) Revision Notice 1: Date Sent to Applicant: Revision Notice 2: Date Sent to Applicant: 'SDC Exemption: 0 Received II. Does not apply SDC Fees Entered: Wash Co Trans Dev Tax: yes 0 N/A Tigard Trans SDC: Er Yes ❑ N/A Parks SDC: ,1� Yes ❑ N/A LIDA 0 Yes ,R(N/A OK to Issue Permit Approved by Permit Coordinator: Aryva AciL Date: 55)l2(20 L\Building\Fmms\BldgPermitRvw_RES_122419.docx L City of Tigard COMMUNITY DEVELOPMENT DEPARTMENT I al 1�- ►�D River Terrace Building Permit Review Addendum lg.r.. . ;,: ;:� Building Permit #: Site Address: JU DO SkAi GOIGt CatSt T e) . Project Name: ?t \ v q,' Rashvi - f2 r� Lot #: 9�(New g=suision name;Addition or Alteration last name of owner) Planning Review of River Terrace Plan District Design Standards (18.640.070.1): Is the project subject to the plan district design standards?XYes No 1.Articulation: a minimum of 1 element per each street-facing facade that has 30-60 ft. of frontage.An additional element required for lots with over 60 ft. of street frontage shall be provided every 30 ft. Porch min Balcony w/ access 2 Window Projection Vertical Wall Offset a . 5 . deep ft. de min.2ft.,5 ft.wide min. 2 ft., 6ft.wide Gabled dormer ❑ ❑ 0 f ° vorg- 2. Eyes the street:a minimum of 12%4f each street facing facade must include windows or entrance doors. Percentage Shown: >,.2° 0 3. F�tftrances: At least one entrance must meet both of the following standards: ®/Max. 8 ft. setback from longe street- facing wall 0 Parallel to street,angle no more than 45° from street, or open onto porch Entrance opens to a porch: Yes 0 No If y(s,all the following apply: sq.ft.min. Cone street facing entry ft.max.roof above floor of porch I7 5 ft. depth min. 30%min.porch roof coverage 4. etailed Design:All buildings shall include a min. of five of the following elements on all street-facing facades: d Covered porch min. 5 ft.wide x 5 ft. deep'e/' 0 Recessed entry area min. 5 ft.wide x 2 ft deep ❑ all offset min. 16 inches ❑ Dormer min.4 ft.wide 44 Roof eave min. 12 inch projectiorif-re- ❑ oof offset min. of 2 ft. ❑ Roof shingles either tile or wood VJ)riable,hip or gambrel roof design ' ❑roof pitch oriented south min. 500 sq. ft orizontal lap siding min. 3-7 inches wide t2 Accent siding min.40%of street facadef Window trim min. 21/2"wide by 5/8"deep ❑ ) 'indow recess min. 3 inches for all street facing ❑ Bay window min. 5 ft.wide by 2 ft. deep l�Balcony min. 5 ft.wide x 3 ft. deep with inside access 0 Attached garage is 35%or less of street facade 5. Garages and Carports:May face the front or side lot line on a com r lot. Setbacks: No closer to front or side lot line, than longest street-facing wall. Yes 0 No. If No (Check one): ❑ May extend up to 5 ft.if there is a covered front porch and garage does not extend beyond the front porch. ❑ May extend up to 5 ft.where the garage is part of a two-story building and there is a window at the second story above a garage that faces the street with a min. area of 12 sq.ft. Wi h: (Check one) 12-foot-wide garage door 0 40%max. of street facade ❑ 50%max. of street facade with 7 detailed design elements Notes: Approved By Planning: — — L__-) Date: O IABui1diug\Forms\B1dgPermrtRvw_RES_RT_121417.docx