Loading...
Report ms r2o2a- / Es EVALUATION Most Widely Accepted and Trusted SERVICE rInnovation �RESEARCH LA6s ICC-ES Evaluation Report ESR-3485 Reissued 10/2018 ICC-ES I (800) 423-6587 I (562) 699-0543 I www.icc-es.org This report is subject to renewal 10/2020. DIVISION: 05 00 00—METALS SECTION: 05 52 00—METAL RAILINGS OFFICE COPY REPORT HOLDER: ULTRALOXTM EVALUATION SUBJECT: ALUMINUM RAILING SYSTEM SERIES V800, C800, M600, 1800, A800, AND 0800 ICC ICC ICC PMG ' LISTED i a "2014 Recipient of Prestigious Western States Seismic Policy CouncilINTERN WSSPC Award in Excellence" COOEcAnoxAl (WSSPC) A Subsidiary of cooecouwcm ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. ANSI There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this ACCREDITED report, or as to anyproduct covered bythe report. s°.e.1065 P P v peon C$1000 °pox flop° Copyright©2018 ICC Evaluation Service, LLC. All rights reserved. ES `r Most Widely Accepted and Trusted - �Innovation ICC-ES Evaluation Report ESR-3485 Reissued October 2018 This report is subject to renewal October 2020. www.icc-es.orq I (800)423-6587 I (562) 699-0543 A Subsidiary of the International Code Council® DIVISION:05 00 00-METALS accordance with the approved quality control Section: 05 52 00-Metal Railings documentation. The railing components are available in a white, black or bronze powder coated finish. REPORT HOLDER: 3.2 Guard: ULTRALOXTM The height of the railing assembly is 42 inches (1067 mm) above the walking surface. The top rail ADDITIONAL LISTEES: cover has a wall thickness of 0.055-inch (1.40 mm); and depending on the top rail series, the overall top WILLIAMS ARCHITECTURAL PRODUCTS TM rail width ranges from 2-inches (50.8 mm) minimum to 2 Vs-inches (63.5 mm) maximum, and the overall HARMONY RAILINGT" top rail depth ranges from 1.92-inches (48.8 mm) minimum to 2.35-inches (59.7 mm) maximum. The EVALUATION SUBJECT: bottom rail cover has a wall thickness of 0.055-inch (1.40 mm), a width of 1 1/2-inches (38.1 mm), and a ALUMINUM RAILING SYSTEM SERIES V800, C800, depth of 1 1/2-inches (38.1 mm). For the sub-rail M600, 1800,A800, and 0800. panels, both top and bottom h-channel rails having a varying wall thicknesses between 0.065-inch (1.65 mm) 1.0 EVALUATION SCOPE and 0.083-inch (2.11 mm) thick, a width of 1.38-inches Compliance with the following codes: (35.1 mm), and a depth of 0.97-inch (24.6 mm). Both top and bottom rail covers and sub-rail panels are available • 2015, 2012, 2009, and 2006 International Residential in 6-foot (1.83 m) and 8-foot (2.44 m) lengths. They are Code®(IRC) produced from 6063-T5 aluminum alloy and come in a Property evaluated: powder coated finish. The maximum railing span for each Aluminum Railing System series is noted in Structural Table 1. 2.0 USES The pickets are hollow rectangular extruded 6063-T5 aluminum. The pickets have a wall thickness of The Aluminum Railing System Series V800, C800, 0.050-inch (1.27 mm), a width of'Is-inch (12.7 mm), and M600, 1800, A800, and 0800 described in this report are a depth of 3/4-inch (19.1 mm) and come in a powder limited to exterior or interior use as a guardrail system coated finish. Each picket is inserted in the pre-punched for balconies, porches, and decks for one- and two- holes on the top and bottom h-channel rails of each family dwellings constructed in accordance with the IRC. sub-rail panel, with a center-to-center spacing of 41/2-inches(114.3 mm). 3.0 DESCRIPTION The posts are 3-inches (76.2 mm) square hollow 3.1 General: extruded 6005A-T5 aluminum with a wall thickness of The Aluminum Railing System Series V800, C800, 0.065-inch (1.65 mm) and come in a powder coated M600, 1800, A800, and 0800 are guards consisting of finish. The post cap is produced from A380 aluminum extruded aluminum posts, sub-rail panel with top and alloy and is installed at the top of the extruded post bottom channel rails and balusters, bottom-rail support and measures 3-inches (76.2 mm) by 3-inches leg, and top and bottom rail covers. The Aluminum (76.2 mm)square.The post base plate is produced from Railing System components are produced from 6063-T5 A380 aluminum alloy and is installed at the bottom of the aluminum alloy, the posts are produced from 6005A-T5 extruded post; it measures 4.99-inches (126.7 mm) by aluminum alloy, and the post caps and post base plates 4.99-inches (126.7 mm) square.The 6-foot(1.83 m)and are produced from A380 aluminum alloy. The Aluminum 8-foot (2.44 m) railing systems utilize one intermediate Railing System is available in six different series: V800, bottom rail support leg located at the midspan. Each C800, M600, 1800,A800, and 0800;where each top rail support leg is a 11/2-inches (38.1 mm) square hollow is described by a designated series: Victorian (V), extruded 6063-T5 aluminum with a wall thickness of Colonial (C), Mission (M), Impressions (I), Aria (A), and 0.052-inch (1.32 mm) and comes in a powder coated Optima (0). The minimum yield and tensile strengths, finish. minimum thickness of the railing components, and The top and bottom rail connector clips are made manufacturing extrusion process are specified in from 0.080-inch (2.03 mm) thick 5052-H32 aluminum ICC-ES Evaluation Reports are not to he construed as representing aesthetics or any other attributes not specifically addressed,nor are they to be construed • 1/w�, as an endorsement of the subject of the report or a recommendation for its use.There is no warranty by ICC Evaluation Service,LLC,express or implied,as to any finding or other matter in this report,or as to any product covered by the report. iviavwww -.. mEm+Q Copyright®2018 ICC Evaluation Service,LLC. All rights reserved- Page 1 of 5 ESR-3485 I Most Widely Accepted and Trusted Page 2 of 5 sheets and measures 1-inch (25.4 mm) wide by the supporting construction, including chemically 0.94-inch (23.9 mm) long by 0.060-inch (1.52 mm)deep, treated wood, is outside the scope of this report. with two 0.16-inch(4.06 mm)diameter holes for securing 5.4 The Aluminum Railing System Series V800, C800, into the post. M600, 1800, A800, and 0800 must be directly See Figure 1 for details of the components for the fastened to supporting construction having aluminum railing system. adequate strength and stiffness. Where required by 4.0 DESIGN AND INSTALLATION the code official, engineering calculations and construction documents consistent with this report 4.1 Design: must be submitted for approval. The calculations The Aluminum Railing System Series V800, C800, must verify that the supporting construction M600, 1800, A800, and 0800 are satisfactory to resist complies with the applicable building code loads specified in IRC Table R301.5, when installed at requirements and is adequate to resist the loads the maximum clear distance between the posts as noted imparted upon it from the products and systems in Table 1. When the railing is supported on one or both discussed in this report. The documents must ends by the supporting structure, the maximum clear contain details of the attachment to the supporting distance between the post and the supporting structure structure consistent with the requirements of this or between the supporting structures must comply with report. The documents must be prepared by a the spans noted in Table 1. registered design professional where required by the statutes of the jurisdiction in which the project is 4.2 Installation: to be constructed. Installation must be in accordance with the 5.5 The top rail of the Aluminum Railing System, manufacturer's published installation instructions, this for use as a handrail, is outside the scope of report, and guard height and opening limitations this report. provisions specified in IRC Section R312. The 6.0 EVIDENCE SUBMITTED manufacturer's published installation instructions must be available at the jobsite at all times during installation. Data in accordance with the ICC-ES Acceptance Criteria for Handrails and Guards(AC273),dated June 2017. Each top and bottom rail cover snaps over the sub-rail 7.0 IDENTIFICATION panel's corresponding top and bottom h-channel rails. The pickets are inserted into the pre-punched holes on 7.1 The Aluminum Railing System Series V800, C800, the top and bottom h-channel rails of the sub-rail panel. M600, 1800, A800, and 0800 described in this The sub-rail panel is then attached to an extrusion post report are identified by a stamp, on each individual on each end by installing top and bottom rail connector piece or on the packaging, bearing the report clips with #8 x 3/4-inch (19.05 mm) long stainless steel holder's name (Ultralox), the product name TEK screws. Four screws (two inside and one on each (Aluminum Railing System Series V800, C800, side) per each top and bottom connector clip, as shown M600, 1800, A800, or 0800), the allowable span, in Figure 1. The bottom rail connector clip must be and the ICC-ES evaluation report number located 3 3/4-inches (95.25 mm)from the top edge of the (ESR-3485). clip to the bottom of the post extrusion at center. All Alternatively,the products described in this report connector clips must be installed with two #8 x 3/4-inch are identified by a stamp, on each individual piece (19.05 mm) long stainless steel TEK screws. Each or on the packaging, bearing the additional listee's support leg is fastened at the midspan of the bottom rail brand name (Williams Architectural Products or with one #8 x 3/4-inch-long (19.05 mm) stainless steel Harmony Railing), the product name (See Table 2 TEK screw. Each extruded post is attached to a post of this report), the allowable span, and the ICC-ES base plate with four M8 x 80 mm long stainless steel lag evaluation report number(ESR-3485). screws, which are fastened on the underside of the post base plate, as shown in Figure 1. The label shall also include the phrase "For Use 5.0 CONDITIONS OF USE in One-and Two-Family Dwellings Only." 7.2 The report holder's contact information is the The Aluminum Railing System Series V800, C800, following: M600, 1800, A800, and 0800 described in this report ULTRALOXT'" comply with, or are a suitable alternative to what is 2955 LONE OAK DRIVE,SUITE 180 specified in, those codes listed in Section 1.0 of this EAGAN, MINNESOTADRI55121 report,subject to the following conditions: www.ultralox.com 5.1 This product is limited to exterior or interior use as a guardrail system for balconies, porches, and decks 7.3 The Additional listee's contact information is the for one- and two-family dwellings constructed in following: accordance with the IRC. WILLIAMS ARCHITECTURAL PRODUCTS"' 5.2 Installation must comply with this report, the 2955 LONE OAK DRIVE, SUITE 180 manufacturer's published installation instructions EAGAN, MINNESOTA 55121 and the applicable code. When the manufacturer's (855)742-7245 published installation instructions differ from this www.williamsrail-fence.com report,this report governs. HARMONY RAILINGTh 5.3 Only those fasteners and fastener configurations 2955 LONE OAK DRIVE,SUITE 180 described in this report have been evaluated for the EAGAN,MINNESOTA 55121 installation of the Aluminum Railing System Series www.harmonyrailinq.com V800, C800 M600, 1800, A800, and 0800. The compatibility of the post base plate's fasteners with , ESR-3485 I Most Widely Accepted and Trusted Page 3 of 5 TABLE 1—MAXIMUM GUARDRAIL SYSTEM SPAN APPLICABLE BUILDING CODE MAXIMUM SPAN PRODUCT NAME IRC '(in) V800 YES 96 C800 YES 96 M600 YES 72 1800 YES 96 A800 YES 96 0800 YES 96 For SI: 1 inch=25.4 mm 'Maximum span is measured from edge-of-support to edge-of-support. TABLE 2—COMPANY NAME AND PRODUCT NAME CORRELATION COMPANY WILLIAMS HARMONY NAME ULTRALOXTM ARCHITECTURAL RAILINGTM PRODUCTS'" C800 C800 C800 V800 - V800 PRODUCT M600 M600 NAME 1800 A800 - - 0800 - - . ESR-3485 I Most Widely Accepted and Trusted Page 4 of 5 4X #8 X 3/4" ♦ -CUP SHEET 1 OF 1 TEK SCREWS STRAIGHT CUP !'.7%%... . TOP RAIL H-CHANNEL -N.,,11%. .1 „ 1 PICKETS i i` STRAIGHT Cl IP 1 j i E1 Ii SNAP_._,. I 1 I . 1 3"POST 05Et 1� N�,1 ram. i� ��j SUPPORT LEG �y 3"POST BASE 4X M8 x 80 MM SCREWS POST ASSEMBLY DETAIL i.38 1 1 0.50 3.00 I"' -1 1-5° i '_____L L' -, Li 1.50 0.97 0.75 . ____i_ j 1 BOTTOM SNAP f N-CI-tANNEL-I PICLEI 1 3.00 SERIES SERIES SERIES 3°'POST SH093100 141-063100 tifflitai0G SERIES P0043300 -2.2 2.50 2.00 2.50 2.50 2.50 Pilligdmi 2.35 1::- 2.38 1 .92 2.25 Wiwi 2.25 2.25 VICTORIAN COLONIAL OPTIMA MISSION I ARIAIMPRESSIONS SERIES SERIES SERIES SERIFS SERIES VT393100 AT093100 IT593100 CT293100 BR093100 MT193100 FIGURE 1—TYPICAL GUARDRAIL ASSEMBLY AND COMPONENT PROFILES • ES [a>aLurtlL.a SERVICE Most Widely Accepted and Trusted ICC-ES Evaluation Report ESR-3485 FBC Supplement Revised October 2018 This report is subject to renewal October 2020. www.icc-es.orq I (800)423-6587 I (562) 699-0543 A Subsidiary of the International Code Council® DIVISION:05 00 00—METALS Section: 05 52 00—Metal Railings REPORT HOLDER: ULTRALOXTM EVALUATION SUBJECT: ALUMINUM RAILING SYSTEM SERIES V800, C800, M600, 1800,A800,and 0800 1.0 REPORT PURPOSE AND SCOPE Purpose: The purpose of this evaluation report supplement is to indicate that Aluminum Railing System Series V800, C800, M600, 1800, A800, and 0800 recognized in ICC-ES master evaluation report ESR-3485, has also been evaluated for compliance with the codes noted below. Applicable code editions: ■ 2017 Florida Building Code—Residential 2.0 CONCLUSIONS The Aluminum Railing System Series V800, C800, and M600 described in Sections 2.0 through 7.0 of the master evaluation report ESR-3485, complies with the Florida Building Code—Residential, provided the design and installation are in accordance with the 2015 International Residential Code provisions noted in the master report. Use of the Aluminum Railing System Series V800, C800, M600, 1800, A800, and 0800 for compliance with the High- Velocity Hurricane Zone provisions of the Florida Building Code—Residential has not been evaluated and is outside the scope of this evaluation report. For products falling under Florida Rule 9N-3,verification that the report holder's quality-assurance program is audited by a quality-assurance entity approved by the Florida Building Commission for the type of inspections being conducted is the responsibility of an approved validation entity (or the code official, when the report holder does not possess an approval by the Commission). This supplement expires concurrently with the master report, issued October 2018. ICC-ES Evaluation Reports are not to he construed as representing aesthetics or any other attributes not specifically addressed,nor are they to be construed 111 as an endorsement of the subject of the report or a recommendation for its use.There is no warranty by ICC Evaluation Service,LLC,express or implied,as to any finding or other matter in this report,or as to any product covered by the report. mm+xmw mme Copyright©2018 ICC Evaluation Service,LLC. All rights reserved. Page 5 of 5