Loading...
Report FPS7Ci7C-r-Q010 (a-ic30 svl V 4 S . - ,_ SYSTEI�/I �$ SENSOR' iiiiiiiii 1 IIIi1111 F F Indoor Selectable- R Output Horns, : ` R E ` of .1 1� E Strobes, and ' . Horn Strobes for Wall Applications I System Sensor L-Series audible visible notification Ifii.;y, ;, • „ products are rich with features guaranteed to cut , ;� • 1 installation times and maximize profits with lower . e zY. !! current draw and modern aesthetics. ` - Features — ` • Updated Modern Aesthetics The System Sensor 4Series offers the most versatile and • Small profile devices for Horns and Horn Strobes easy-to-use line of horns,strobes,and horn strobes in the industry • Plug-in design with minimal intrusion into the back box with lower current draws and modern aesthetics.With white and red plastic housings,standard and compact devices,and plain,FIRE, • Tamper-resistant construction and FUEGO-printed devices,System Sensor L-Series can • Automatic selection of 12-or 24-volt operation at 15 and 30 meet virtually any application requirement. candela • Field-selectable candela settings on wall units: The L-Series line of wall-mount horns,strobes,and horn strobes 15,30,75,95, 110, 135,and 185 include a variety of features that increase their application versatility • Horn rated at 88+dBA at 16 volts while simplifying installation.All devices feature plug-in designs • Rotary switch for horn tone and two volume selections with minimal intrusion into the back box,making installations fast and foolproof while virtually eliminating costly and time-consuming • Mounting plate for all standard and all compact wall units ground faults. • Mounting plate shorting spring checks wiring continuity before device installation To further simplify installation and protect devices from construction • Electrically compatible with legacy SpectrAlert and SpectrAlert damage,the L-Series utilizes a universal mounting plate for all Advance devices models with an onboard shorting spring,so installers can test wiring • Compatible with MDL3 sync module continuity before the device is installed. • Strobes and Horn Strobes listed for wall mounting only Installers can also easily adapt devices to a suit a wide range • Horns listed for wall or ceiling use of application requirements using field-selectable candela settings, automatic selection of 12-or 24-volt operation,and a rotary switch for horn tones with two volume selections. Agency Listings C }r ;�� L ® _) ,: M APPPOV30 I ` ``Eft.Y (j 5555512 T� FM approved e.cept 7125-16530501 \I I' 2 - 2020 54011 for ALERT models 7135-1653{603 3057333,3057072 aa` .l'I t OF"FIG :"i � 5, Lill!!_.D I!` G !J I I S I ON AVDS865.05.2/22/2018.Page 1 L-Series Specifications Architect/Engineer Specifications General L-Series standard horns,strobes,and horn strobes shall mount to a standard 2 x 4 x 17/8-inch back box,4 x 4 x 11/2-inch back box,4-inch octagon back box,or double-gang back box.L-Series compact products shall mount to a single-gang 2 x 4 x 17/e-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products for all standard models and a separate universal mounting plate shall be used for mounting wall compact models.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,L-Series products,when used with the Sync•Circuit°'Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts:24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15,30,75,95, 110, 135,and 185. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize Strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 411/is x 41'/16 x 21/e-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V(12 V nominal)or 16.5 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions(including lens) 5.6"L x 4.7-W x 1.91-D(143 mm L x 119 mm W x 49 mm D) Compact Wall-Mount Dimensions(including lens) 5.26"L x 3.46"W x 1.91"D(133 mm L x 88 mm W x 49 mm D) Horn Dimensions 5.6"L x 4.7"W x 1.25"D(143 mm L x 119 mm W x 32 mm D) Compact Horn Dimensions 5.25"L x 3.45"W x 1.25"D(133 mm L x 88 mm W x 32 mm D) 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. • 2.Strobe products will operate at 12 V nominal only for 15 cd and 30 cd. • AVDS865-05•2/22i2018•Page 2 UL Current Draw Data - UL Max.Strobe Current Draw(mA RMS) UL Max.Horn Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC DC FWR Sound Pattern dB DC DC FWR Candela 15 88 43 60 Temporal High 39 44 54 Range 30 143 63 83 Temporal Low 28 32 54 75 N/A 107 136 Non-Temporal High 43 47 54 95 N/A 121 155 Non-Temporal Low 29 32 54 110 N/A 148 179 3.1 KHz Temporal High 39 41 54 135 N/A 172 209 3.1 KHz Temporal Low 29 32 54 185 N/A 222 257 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UL Max.Current Draw(mA RMS),Wall Horn Strobe,Candela Range(15-185 cd) 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 98 158 54 74 121 142 162 196 245 Temporal Low 93 154 44 65 111 133 157 184 235 Non-Temporal High 106 166 73 94 139 160 182 211 262 Non-Temportal Low 93 156 51 71 119 139 162 190 239 3.1K Temporal High 93 156 53 73 119 140 164 190 242 3.1K Temporal Low 91 154 45 66 112 133 160 185 235 3.1K Non-Temporal High 99 162 69 90 135 157 175 208 261 3.1K Non-Temporal Low 93 156 52 72 119 138 162 192 242 16-33 Volts FWR Input 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 83 107 156 177 198 234 287 Temporal Low 68 91 145 165 185 223 271 Non-Temporal High 111 135 185 207 230 264 316 Non-Temportal Low 79 104 157 175 197 235 283 3.1K Temporal High 81 105 155 177 196 234 284 3.1K Temporal Low 68 90 145 166 186 222 276 3.1K Non-Temporal High 104 131 177 204 230 264 326 3.1K Non-Temporal Low 77 102 156 177 199 234 291 Horn Tones and Sound Output Data Horn and Horn Strobe Output(dBA) 8-17.5 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 11 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 9* Coded High 85 90 90 10* 3.1 KHz Coded High 84 89 89 "Settings 9 and 10 are not available on 2-wire horn strobes.Temporal coding must be provided by the NAC.If the NAC voltage is held constant,the horn output remains constantly on. AVDS865-05•2/22/2018•Page 3 L-Series Dimensions tg+' 3A6' 3.88' 465 mm 13 mm 136' 3.57 t65" 88 mm - US 3emm (9.1 cm) (9A m6) 12 mm — �, 1/ `'' ,4`,'d`T4 yJ',Th 1 IN ,€. o 1 es '00000001,000c LW o 0 ocLar C O : C 198.9 mm 1iIJ (13.T cm)1339mm ^,o,o,s,o,t,a IE O stt,,,t,t,t,t o A0548-00 60547-00 A0557-00 Compact Strobe,Horn Strobe Compact Horn Compact Wall Surface Mount Back Box SBBGRL,SBBGWL 01"94 cm) __._ 1.91' 119m 4.T 35' (425 cm) m US 1Z5' SY mm / ry334 cm) (469 an) _ (3.18 mm) ,i (� / 1!:::::: .ri 5.87• "•'•'•'•'.' 5.87• 5 o141mm(14.4 an) gq ,III.. 1 70A0650-00 A0599-00 8055-0 01 Strobe,Horn Strobe Horn Wall Surface Mount Back Box SBBRL/SBBWL L-Series Ordering Information Model Description Model Description Wall Horn Strobes Horns* P2RL 2-Wire,Horn Strobe,Red HRL* Horn, Red P2WL 2-Wire,Horn Strobe,White HWL' Horn,White P2GRL 2-Wire,Compact Horn Strobe, Red HGRL* Compact Horn,Red P2GWL 2-Wire,Comp 2 fils act Horn Strobe,White HGWL* Compact Horn,White P2RL-P 2-Wire,Horn Strobe,Red,Plain Accessories P2WL-P 2-Wire,Horn Strobe,White, Plain TR-2 Universal Wall Trim Ring Red P2RL-SP 2-Wire, Horn Strobe,Red,FUEGO TR-2W Universal Wall Trim Ring White P2WL-SP 2-Wire, Horn Strobe,White, FUEGO SBBRL Wall Surface Mount Back Box,Red P4RL 4-Wire,Horn Strobe,Red SBBWL Wall Surface Mount Back Box,White P4WL 4-Wire,Horn Strobe,White SBBGRL Compact Wall Surface Mount Back Box,Red Wall Strobes SBBGWL Compact Wall Surface Mount Back Box,White SRL Strobe,Red SWL Strobe,White SGRL Compact Strobe,Red SGWL Compact Strobe,White SRL-P Strobe,Red,Plain SWL-P Strobe,White,Plain SRL-SP Strobe,Red,FUEGO SWL-CLR-ALERT Strobe,White,ALERT Notes: All-P models have a plain housing(no"FIRE"marking on cover). All-SP models have"FUEGO"marking on cover. All-ALERT models have'ALERT"marking on cover. 'Horn-only models are listed for wall or ceiling use. *� SYSTEM 3825 Ohio Avenue•St.Charles, IL 60174 ©901B System Sensor �1� SENSOR Phone:800-SENSOR2•Fax:630-377-6495 Product specificationsificationssubject to change nhoutnotice.ionUItslerrsensamm for current product inla-nation.including me latest version of this data sheet. www.systemsensor.com systemsensoccom AV0S865-05.2/22/2018 SYSTEM SENSOR Outdoor Selectable- Output Horns, aYit E . Strobes, and Horn Strobes for Wall Applications SPECTF Alert SpectrAlert Advance outdoor audible visible products &Army are rich with features that cut installation times and maximize profits. Features SpectrAlert Advance offers the broadest line of outdoor horns, • Weatherproof per NEMA 4X, IP56 strobes,and horn strobes in the industry.With white or red plastic housings,wall or ceiling mounting options,and plain or FIRE-printed • Listed to UL 1638(strobe)and UL 464(horn) devices,SpectrAlert Advance can meet virtually any application • Compatible with System Sensor synchronization protocol and requirement,including indoor,outdoor,wet,and dry applications in legacy SpectrAlert products temperatures from-40°F to 151°F. • Field-selectable candela settings: 15, 15/75,30,75,95, 110, 115, 135, 150, 177,and 185 Like the entire SpectrAlert Advance line,outdoor horns,strobes, and horn strobes for wall applications include a variety of features • Automatic selection of 12-or 24-volt operation at 15 and that increase application flexibility and simplify installation. First, • 15/75 candela field-selectable settings, including candela,automatic selection of • Rotary switch for horn tone and three volume selections 12-or 24-volt operation, horn tones,and three volume options enable • installers to easily adapt devices to meet requirements. • Horn rated at 88+dBA at 16 volts • • Rated from-40°F to 151°F Next,SpectrAlert Advance devices use a universal mounting plate • Universal mounting plate with an onboard shorting spring that for both wall and ceiling applications.This mounting plate includes tests wiring continuity before devices are installed an onboard shorting spring that ensures wiring continuity before Plug-in design with minimal intrusion into the back box devices are installed,so installers can verify proper wiring without • mounting the devices and exposing them to potential construction • Tamper-resistant construction damage.Once the plates are mounted, all SpectrAlert Advance • Listed for ceiling or wall mounting devices utilize a plug-in design with a single captured screw to speed installation and virtually eliminate costly ground faults. Outdoor devices ship with weatherproof plastic back boxes(metal back boxes are available separately)that accommodate in-and- Agency Listings out wiring for daisy chaining devices. Plastic back boxes feature removable side flanges and improved resistance to saltwater ;Tr corrosion. Knock-outs located on the back eliminate the need to drill SIGNALING r O holes for screw-in mounting.Plastic and metal weatherproof back uL MEA I I boxes come with 3/4-inch top and bottom conduit entries and 3/4-inch LISTED 7300-1653 18➢(emnen,strobes) approved 7125-ss3,88(horn sbnbes, knock-outs at the back.A screw-in NPT plug with an 0-ring gasket 54011(chmes,horn strobes.horns) APPROVED chime strobes) 53593(octdoor and alert strobes) 3023572 MEA452-05-E 7135-1653.189(horns.chimes) for a watertight seal is included with each back box. SpectrAlert Advance Outdoor Horn, Strobe,and Horn Strobe Specifications Architect/Engineer Specifications General SpectrAlert Advance outdoor horns,strobes,and horn strobes shall mount to a weatherproof back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate. Also,SpectrAlert Advance products,when used with the Sync•Circuit`'Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts.Outdoor SpectrAlert Advance products shall operate between-40 and 151 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply.Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75,30,75,95, 110, 115, 135, 150, 177,and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL.The strobe shall be suitable for use in wet environments. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options shall be set by a multiple position switch. On four-wire products,the strobe shall be powered independently of the sounder.The horn or horn strobe models shall operate on a coded or non-coded power supply.The horn strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The horn strobe shall be suitable for use in wet environments. Physical/Electrical Specifications Operating Temperature -40°F to 151°F(-40°C to 66`C) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions(including lens) 5.6"L x 4.7"W x 2.5"D(142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6"L x 4.7""W x 1.3"D(142 mm L x 119 mm W x 33 mm D) Wall-Mount Weatherproof Back Box Dimensions(SA-WBB) 5.7"L x 5.1"W x 2.0"D(145 mm L x 130 mm W x 51 mm D) Notes: 1. Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2. P,S,PC,and SC products will operate at 12 V nominal only for 15 and 15/75 cd. AVOS01201 UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) UL Max.Horn Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela 15/75 142 148 77 81 Temporal Medium 44 49 58 69 Range 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non-Temporal High 57 56 69 75 95 NA NA 181 176 Non-Temporal Medium 42 50 60 69 110 NA NA 202 195 Non-Temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela 150 NA NA 246 220 Coded Low 40 46 52 50 Range 177 NA NA 281 251 185 NA NA 286 258 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,Standard Candela Range(15-115 cd) 8-17.5 Volts 16-33 Volts DC Input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,High Candela Range(135-185 cd) 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Candela Derating Horn Tones and Sound Output Data For K series products used at low temperatures, listed Horn and Horn Strobe Output(dBA) i candela ratings must be reduced in accordance with 8-17.5 16-33 24-Volt Nominal this table. Strobe Output(cd) Switch Sound Volts Volts Reverberant Anechoic Position Pattern dB DC FWR DC FWR DC FWR DC FWR Listed Candela Candela rating at-40`F 1 Temporal High 78 78 84 84 88 88 99 98 15 2 Temporal Medium 74 74 80 80 86 86 96 96 15/75 Do not use below 32°F 3 Temporal Low 71 73 76 76 83 80 94 89 30 4 Non- High 75 44 Temporal 82 82 88 88 93 92 100 100 95 70 5 Non- Medium 110 110 Temporal 78 78 85 85 90 90 98 98 115 115 6 Non- Low 75 75 81 81 88 84 96 92 135 135 Temporal 150 150 7t Coded High 82 82 88 88 93 92 101 101 177 177 8t Coded Medium 78 78 85 85 90 90 97 98 185 185 9t Coded Low 75 75 81 81 88 85 96 92 tSettings 7,8, and 9 are not available on 2-wire horn strobe. AV0S01201 SpectrAlert Advance Diagrams 14-4.TTLL 2.5� ice..` ' 5.6" ,_ ,0 `� O iI III je,.._19 1111 ii:L•ur'-i i\:::-'-'-'111\t'Slik 4**---d Wall-Mount Horn Strobes ",-,,.-,.-.-0,t -,_,.-._.-.--_--a-_-T- --.'7-=A----- Wall Plastic Weatherproof Back Box 0 1---- A`1Ii. !iaIiijs$, i I - ill Wall-Mount Horn Strobe with Plastic Weatherproof Back Box SpectrAlert Advance Ordering Information Model Description Wall Horn Strobes P2RK*1 2-Wire Horn Strobe,Standard cd,Red,Outdoor(includes plastic weatherproof back box) P2RHK"t 2-Wire Horn Strobe,High cd,Red,Outdoor(includes plastic weatherproof back box) P2WK"t 2-Wire Horn Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) P2WHK*t 2-Wire Horn Strobe,High cd,White,Outdoor(includes plastic weatherproof back box) P4RKt 4-Wire Horn Strobe,Standard cd,Red,Outdoor(includes plastic weatherproof back box) P4WK 4-Wire Horn Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) P2RHK-120 2-Wire Horn Strobe,High cd,Red,Outdoor, 120 V(includes plastic weatherproof back box) Wall Strobes SRK"t Strobe,Standard cd, Red,Outdoor(includes plastic weatherproof back box) SRHK"t Strobe,High cd,Red,Outdoor(includes plastic weatherproof back box) SWK*t Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) SWHK*t Strobe,High cd,White,Outdoor(includes plastic weatherproof back box) Horns HRK-r Horn,Red,Outdoor(includes plastic weatherproof back box) Accessories SA-WBB Red,Metal Weatherproof Back Box SA-WBBW White,Metal Weatherproof Back Box Notes: "Add"-P"to model number for plain housing(no"FIRE"marking on cover),e.g.,P2RK-P. t Add"-R"to model number for weatherproof replacement device(no back box included),only for use with weatherproof outdoor flush mounting plate,WIP and WTPW. "Standard cd"refers to strobes that include 15,15/75,30,75,95,110,and 115 candela settings."High cd"refers to strobes that include 135,150,177,and 185 candela settings.When replacing standard outdoor units both the device and back box must be replaced. *-' SYSTEM ©2012 System Sensor. ``l 3825 Ohio Avenue•St.Charles, IL 60174 Product specnicatiuns subject to change without notice Visa systemsensorcom l SENSOR Phone:800-SENSOR2• Fax:630-377-6495 for current product infatuation.Includng the latest version of this data sheet AVDS01201•3/12 Honeywell ®SILENT. KNIGHT SK-PHOTO-W Series Intelligent Plug-In Photoelectric Smoke Detector Honeywell Silent Knight SK-PHOTO-W Series plug-in smoke detectors are designed for both performance and aesthetics.A new modern,sleek, contemporary design and enhanced optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources in accordance with more stringent code standards. The SK-PHOTO-W Series detector sensitiv ty can be programmed in the control panel software.Sensitivity is continuously monitored and reported to the panel.Point ID capability allows each detector's address to be set (+ with rotary,decimal address switches,providing exact detector location for selective maintenance when chamber contamination reaches an unacceptable level. Dual electronic thermistors add 135°F(57°C)fixed temperature thermal sensing on the SK-PHOTO-T-W.The SK-PHOTO-R-W is a remote test SK-PHOTO-W capable detector for use with DNR Series duct detector Housings FEATURES & BENEFITS • New modern profile for • Dual LED design • Expanded color • Optional relay, • improved aesthetics provides 360°viewing options isolator,and sounder • Stable communication angle • SEMS screws for bases technique with noise • Remote test feature wiring of the separate • Plugs into separate immunity from the panel base base for ease of installation and • Low standby current • Built-in functional test • Two-wire SLC switch activated by maintenance connection external magnet • Built-intamper- • Optional remote, single-gang LED resistant feature accessory • Sealed against back pressure DETECTOR SPACING AND INTELLIGENT BASES ACCESSORIES APPLICATIONS B300-6:White,standard flanged CK300:Color Kit(includes cover and Honeywell recommends spacing low-profile mounting base. - trim ring),white,10-Pack. detectors in compliance with NFPA 72. B300-6-BP:Bulk pack of B300-6, CK300-IV: Color Kit(includes cover In low airflow applications with smooth package contains 10. and trim ring),ivory,10-Pack. ceiling,space detectors 30 feet(9m). B300-6-IV:Ivory,standard flanged CK300-BL:Color Kit(includes cover For specific information regarding low-profile mounting base. and trim ring),black, 10-Pack. detector spacing,placement,and 6501-WHITE:White,standard MO2-04-01: Detector test magnet. special applications refer to NFPA 72. European flangeless mountingbase.UL P 9 M02-09-00:Telescoping test magnet. System Smoke Detector Application listed. RA100Z:Remote LED annunciator Guide,document A05-1003,is available at systemsensorcom B501-BL:Black,standard European SMB600:Surface Mounting Kit - flangeless mounting base.UL listed. (flanged). INSTALLATION B501-IV:Ivory,standard European TR300:Replacement trim ring for flangeless mounting base.UL listed. B300 6,white. The SK-PHOTO-W Series plug-in detectors use a separate base to B200S-WH:White,Intelligent, TR300-IV:Replacement trimring for simplify installation,service,and programmable sounder base. B300-6-IV,ivory. maintenance. Installation instructions 6200S-IV:Ivory, Intelligent, are shipped with each detector. programmable sounder base. B200SR-WH:White,Intelligent sounder Mount base(all base types)on an base for retrofit applications. electrical backbox which is at least 1.5" B200SR-IV:Ivory, Intelligent sounder (3.81 cm)deep. base for retrofit applications. NOTE: B200S-LF-WH:White,Low Frequency Intelligent,programmable sounder • Because of the inherent supervision base. provided by the SLC loop,end-of-line resistors are not required.Wiring B200S-LF-IV:Ivory, Low Frequency "T-taps"or branches are permitted for Intelligent,programmable sounder Style 4(Class"B")wiring. base. B200SR-LF-WH:White,Low •When using relay or sounder bases, Frequency Intelligent sounder base for consult the installation sheet for device retrofit applications. limitations between isolator modules B200SR-LF-IV:Ivory,Low Frequency and isolator bases. Intelligent sounder base for retrofit applications. ORDERING INFORMATION B224RB-WH:White,plug-in System SK-PHOTO-W:Photoelectric smoke Sensor relay base. detector,white. B224RB-IV:Ivory,plug-in System SK-PHOTO-R-W:Photoelectric smoke Sensor relay base. detector,remote test capable,for use B224BI-WH:White, plug-in System with DNR(W)duct smoke detectors, Sensor isolator detector base. white B224BI-IV: Ivory,plug-in System SK-PHOTO-T-W:Photoelectric smoke Sensor isolator detector base. detector with thermal sensing,white. SK-PHOTO-W Series Detector Technical Specifications PHYSICAL COMPATIBILITY For a complete listing of all compliance approvals and Height:2.0"(51mm)installed in B300-6 base The SK-PHOTO-W series detectors are certifications,please visit Diameter:6.2"(156mm)installed in B300-6 compatible with the following Honeywell Silent www.silentknight.com. base 4.1"(104 mm)installed in B501 base Knight fire alarm control panels: Microsoft,Windows,and the Windows Logo are Weight:3 4 n7(95 g) 6820:Addressable fire alarm control panel registered trademarks 6820EVS:Addressable fire alarm control panel or trademarks of ENVIRONMENTAL Microsoft Corporation with an emergency voice system. Operating Temperature range: Silent Knight",System 6808:Addressable fire alarm control panel Sensor'and Honeywell' Photo:32°F to 122°F(0°C to 50°C) are registered Photo with Thermal:32°F to 100°F(0°C to 6700:Addressable fire alarm control panel trademarks of Honeywell 5700:Addressable fire alarm control panel International,Inc. 38°C) This document is not UL listed Velocity range:Photo/Photo with 5808:Addressable fire alarm control panel intended to be used for 5820XL:Addressable fire alarm control panel installation purposes.We Thermal 0 to 4,000 fpm(0 to 20 m/sec) try to keep our product (suitable for installation in ducts) 5820XL-EVS:Addressable fire alarm control information up-to date and accurate.We Humidity:10%to93%non-condensing panel with an emergency voice system cannot cover all specific applications or anticipate Thermal Ratings:Fixed Temperature Set point: AGENCY LISTINGS AND APPROVALS all requirements.All 135°F(57°C) For exact certification listings for each model, specifications are subject please reference the respective agency Web site. to change without notice. ELECTRICAL RATINGS UL listed:S6173 For Technical Support, Voltage Range:15 to 32VDC peak FM approved call 800 446 6444. CSFM: 7272-0559:0523 Operating Current®24VDC:200pA(one communication every 5 seconds with green LED blink on communication) Maximum Current:4.5mA®24VDC(one communication every 5 seconds with amber LED solid on). For more information Learn more about Honeywell Silent Knight and other products by visiting www.silentknight.com 2 Honeywell Silent Knight Honeywell 12 Clintonville Road N o rthford.CT 06472 Doc 3516341 Rev A 104/18 ®SILENT' 800-328-0103 ©2018 Honeywell International Inc. KNIGHT Honeywell DSILENT" KNIGHT SK-HEAT-W Series Intelligent Thermal (Heat) Detector Honeywell Silent Knight SK-HEAT-W Series intelligent thermal detectors are designed for both performance and aesthetics.A new modern,sleek. contemporary design and advanced thermal technologies make the SK-HEAT-W Series ideal for both system operation and building design. The point ID address,set using rotary decimal switches, provide specific detector locations.The series includes a 135°F/57°C fixed temperature, rate-of-rise and a 190°F/88°C fixed high temperature detectors.These (, thermal detectors provide effective,intelligent property protection in a ,, variety of applications. SK-HEAT-W FEATURES & BENEFITS • Sleek and stylish • High temperature • 360°-field viewing • Built-in functional-test • Sealed against back contemporary design model(SK-HEAT- angle of the visual switch activated by pressure • Advanced thermal W-HT)factory preset alarm indicators(two external magnet to 190°F(88°C) bi-color LEDs).LEDs • Plugs into separate technology for fast • Walk test with address base for ease of response • Addressable by device blink green in Normal display(an address of installation and condition and turn on 121 will blink the maintenance • Fixed temperature • Two-wire SLC steady red in Alarm. detector LED 12- model(SK-HEAT-W) connection • SEMS screws for factorypreset to • Integral (pause)-1) wiring of the separate ° ° • Visible LEDs"blink" communications and 135°F(57°C) everytime the unit is • Low standby current base built-in device-type • Rate-of-rise model addressed identification • Designed for • Optional remote, (SK-HEAT-W-ROR), , guilt-in tam er- directsurface or single-gang LED 15°F(8.3°C)per p • Remote test feature electrical box accessory resistant feature from the panel minute mounting APPLICATIONS INTELLIGENT BASES ACCESSORIES Use thermal detectors for protection of B300-6:White,standard flanged CK300:Color Kit(includes cover and property. For further information,refer low-profile mounting base. trim ring),white,10-Pack. to manual 156-6541,Applications B300-6-BP:Bulk pack of B300-6, CK300-IV: Color Kit(includes cover Manual for System Smoke Detectors, package contains 10. and trim ring),ivory,10-Pack. which provides detailed information on B300-6-IV:Ivory,standard flanged CK300-BL:Color Kit(includes cover detector spacing,placement,zoning, low-profile mounting base. and trim ring),black,10-Pack. wiring,and special applications B300A-6-IV:Ivory,standard flanged M02-04-01: Detector test magnet. low-profile mounting base.UL listed. M02-09-00:Telescoping test magnet. INSTALLATION B501-WH ITE:White,standard RA100Z:Remote LED annunciator The Sh I-EAT-W Series plug-in European flangeless mounting base.UL intelligent thermal detectors use a SMB600:Surface Mounting Kit listed. (flanged). separate base to simplify installation, g service,and maintenance. Installation B501-BL:Black,standard European TR300:Replacement trim ring for flangeless mounting base.UL listed. B300-6,white. instructions are shipped with each detector B501 IV:Ivory,standard European TR300-IV:Replacement trimring for flangeless mounting base.UL listed. B300-6-IV,ivory.. Mount base(all base types)on an B200S-WH:White,Intelligent, electrical backbox which is at least 1.5" programmable sounder base. (3.81 cm)deep. B200S-IV: Ivory,Intelligent, programmable sounder base. NOTE: B200SR-WH:White,Intelligent sounder • Because of the inherent supervision base for retrofit applications. provided by the SLC loop,end-of-line B200SR-IV:Ivory,Intelligent sounder resistors are not required.Wiring base for retrofit applications. "T-taps"or branches are permitted for Style 4(Class"B")wiring. B200S-LF-WH:White, Low Frequency Intelligent,programmable sounder •When using relay or sounder bases, base. consult the installation sheet for device B200S-LF-IV:Ivory,Low Frequency limitations between isolator modules Intelligent,programmable sounder and isolator bases. base. NOTE:Detectors must be mounted to one B200SR-LF-WH:White, Low of the Intelligent Bases listed below. Frequency Intelligent sounder base for ORDERING INFORMATION retrofit applications. SK HEAT W:Thermal heat detector, B200SR-LF-IV:Ivory,Low Frequency 135°F fixed,white. Intelligent sounder base for retrofit SK-HEAT-ROR-W:Thermal heat applications. detector,135°F rate of rise,white. B224RB-WH:White,plug-in System SK-HEAT-HT-W:Thermal heat detector, Sensor relay base. 190°F high temp,white. B224RB-IV:Ivory,plug-in System Sensor relay base. 6224BI-WH:White, plug-in System Sensor isolator detector base. B224BI-IV: Ivory,plug-in System Sensor isolator detector base. SK-HEAT-W Series Detector Technical Specifications • PHYSICAL COMPATIBILITY Fora complete listing of all compliance approvals and Height:2.0'(51mm)installed in B300-6 base The SK-HEAT-W series detectors are certifications,please visit Diameter:6.2"(156mm)installed in 8300-6 compatible with the following Honeywell Silent www.silentknight.com. base 4.1"(104 mm)installed in B501 base Knight fire alarm control panels: Microsoft,Windows,and the Windows Logo are Weight:3.4 oz(95 g) 6820:Addressable fire alarm control panel registered trademarks 6820EVS:Addressable fire alarm control panel Mi ro soft Corpo ENVIRONMENTAL Microsoft Corpofration Operating Temperature range: with an emergency voice system. y Silent Knight',5 stem 6808:Addressable fire alarm control panel Sensor4i and Honeywell' Heat-Fixed temperature:-4°F to 100°F(-20°C are registered to 38°C) 6700:Addressable fire alarm control panel trademarks of Honeywell International,Inc. Heat-Rate of Rise(ROR):-4°F to 100°F(-20°C 5700:Addressable fire alarm control panel Th0 5808:Addressable fire alarm control panel s document is not to 38 C) intended to be used for ° ° ° 582OXL:Addressable fire alarm control panel installation purposes.We Heat-High Temperature:-4 F to 150°F(-20 C try to keep our product to 66°C) 5820XL-EVS:Addressable fire alarm control information up-to 0 o panel with an emergency voice system date and accurate.We Humidity:10 /o to 93 /o non-condensing cannot cover all specific applications or anticipate Thermal Ratings:Fixed Temperature Set point: AGENCY LISTINGS AND APPROVALS all requirements.All 135°F(57°C) For exact certification listings for each model, specifications are subject please reference the respective agency Web site. to change without notice Rate-of-Rise Detection:15°F/min.(8.3°C/min UL listed:S2101 For Technical Sup port, High Temperature Heat:190°F(88°C)Etectrical FM Approved call 800-446-6444 Ratings CSFM:7270-0559:0511 ELECTRICAL RATINGS Voltage Range: 15 to 32VDC peak Standby current(max.avg.):200uA @ 24 VDC (one communication every 5 seconds with LED enabled). LED current(max.):4.5mA 24 VDC("ON"). For more information _cam more about Honeywell Silent Knight and other oroducts by visiting wwwsilentknight.com Honeywell Silent Knight • 12 Clintonville Roac Honeywell Northford.CT 06472 Doc 3516371 Rev 104/18 SILENT' 800-328-0103 ©2018 Honeywell International Inc. ®KNIGHT SILENT SK-Pull-SA and SK-Pull-DA KNIGHT by Honeywell Intelligent Pull Stations The SK-Pull-SA and SK-Pull-DA are a single action or dual action addressable fire alarm pull station for use with Silent Knight's IntelliKnight fire control panel. Extremely easy to operate, the SK-Pull-DA and SK-Pull-SA provide a fast and practical means of manually initiating a fire alarm signal. The IntelliKnight panel recognizes each manual pull station by its specific address saving precious seconds in determining the location of an alarm. For more information about the IntelliKnight system, or to locate you nearest source, please call 1-800-328-0103. Description The SK-Pull-SA is a single action pull station requiring only one motion to activate the station. The SK-Pull-DA is a dual R action pull station requiring two motions to active the station. Both pull stations are designed to work with Silent Knight I PULL DOWN Intelliknight series fire alarm control panels (FACPs). Features • Installer can open station without causing an alarm condition ti • Dual-color LED is visible through handle of station blinks "" a green to indicate normal operation and remains steady red in an alarm condition SK-PuII-SA • Key operated test and reset lock using lock plate actuator • Key matches compatible FACP locks FIR E • Meets the Americans with Disabilities Act Accessibility Guidelines (ADAAG) controls and operating mechanisms 1 PUSH iN guidelines (Section 4.1.3[13]) iPULLDOWNl • Meets ADA requirement for 5 lbs maximum pull force to active • Shell, door, and handle molded from durable LEXAN® sn cxr • Reliable analog communications for trouble-free operation c • Braille text on station handle SK-PuII-DA • Handle latches in down position and the word Activated Compatibility appears, clearly indicating the station has been pulled The SK-Pull-SA and SK-Pull-DA are compatible • Rotary address switches for fast installation with the following IntelliKnight FACP's: 5600 • UL Listed, including UL 38, Standard of Manually Actuated 5700 Signaling System 5808 5820XL 5820XL-EVS Model SK-Pull-DA and SK-PuIl-SA Intelligent Pull Stations Engineering Specifications The contractor shall furnish and install where indicated on the plans,Addressable Pull Stations, Silent Knight model SK-Pull-SA single action pull station or SK-Pull-DA, dual action pull station. SK-Pull-DA or SK-Pull-SA meet the ADAAG controls and operating mechanisms guidelines, and the ADA requirements for a 5 lb. maximum pull force to activate the pull station. isa.o Class A iivs .... IN M,_ ....... - --- OUT mo:: i Ili,. ( Class B i I i Compatible FACP us r , t t i1 Cris g eel "� n 7, i e I t I r r I a Class Wiring Class B Miring: I am 1P: Wiring SK-Pull-SA& SK-Pull-DA Pull Stations Specifications Electrical Operating Voltage: 15-32 VDC Physical Height: 5.5" (14 cm) Average Operating Current (LED flashing): 300 pA Width: 4" (10.2 cm) Wire Gauge: Up to 12 AWG (3.1 mm2) Depth: 5.4 oz. (3.7 cm) Environmental Housing Material: LEXAN polycarbonate resin Operating Temperature 32°- 120°F (0°C-49°C) 0 0 Bi-Colored LED: Humidity: 10/o-93/o non-condensing 9 Blinking Green: Normal Steady Red:Alarm Accessories Switch: Single pole, single throw(SPST) normally open (N/O) BG-TR Optional trim ring. switch which closes upon activation of the pull station SB-I/O Surface backbox 1 This document is not intended to be used for installation purposes.We tr y MADE IN AMERICA SILENT to keep our product information up-to-date and accurate.We cannot cover To KNIGHT all specific applications or anticipate all requirements.All specifications are it subject to change without notice. For more information,contact Silent FORM#350135 Rev C by Honeywell Knight 12 Clintonville Road, Northford, CT 06472-1610 ©2013 Honeywell International Inc. Phone: (800)328-0103, Fax: (203)484-7118. For Technical Support, Please call 800-446-6444. www.silentknight.com SILENT SK-Monitor KNIGHT by Honeywell Intelligent Monitor Module The SK-Monitor module provides an interface to contact devices, such as security contacts, waterflow switches, or pull stations. For more information about the IntelliKnight system, or to locate you nearest source, please call 1-800-328-0103. Description The SK-Monitor is an addressable monitor module for use with Silent Knight IntelliKnight series fire alarm control panels (FACPs). The SK-Monitor is intended for use in intelligent, two-wire systems, where individual address of each module is selected using the built-in rotary switches. ' The SK-Monitor supports Class A supervised or Class B supervised wiring to the load device. Conventional 4-wire smoke detectors can be monitored for alarm and trouble •„,„ conditions. '�• Features • Single contact monitor • Support for Class A and Class B wiring • Fully supervised • Panel controlled status LED that flashes green in normal state and is solid red in alarm • Attractive ivory cover plate SK-Monitor • Rotary address switches for fast installation • SEMS screws for easy wiring Specifications • UL Listed Physical Installation Height: 4.5" (11.4 cm) The SK-Monitor mounts directly into a 4" square electrical Width: 4" (10.2 cm) box. The box must have a minimum depth of 2-1/8".A Depth: 1.25" (3 cm) surface mount electrical box (System Sensor® PN Shipping Weight: 6.3 oz (196 g) SMB500) is available from Silent Knight. Electrical Compatibility Operating Voltage: 15 —32 VDC The SK-Monitor is compatible with the following Current Draw (LED on): 5.0 mA max IntelliKnight FACP's: Operating Current (LED flashing): 375 pA 5700 5808 5820XL 5820XL-EVS Model SK-Monitor Intelligent Monitor Module TO NEXT - FROM FRIEL OR DEVICE . �`►+aa �a+a` 'a.sa+.saa Ni PREVIOUS DEVICE $ i &IDIOM I f AM'SUNNIER CF IA LISTED CONTACT (-1 MODULE n CSOW%DEA MODULES MAY EE USED.DO MDT MX ' 4, t CONNECT MODS TO LISTED COMPATIBLE FETE ALARA INTIATNG,BLPEFMEORY,OR O 4 L I 0 COMIROL FRIB MA BOr _461 BECUUTf°PACES°NTNE SAYE NONE ' $ • 011, ill`� f. RESISTOR , — i EL R IX '— l � / I NIT INTNB DHAOE CETCUtT SOO)-NFPA STYLE B POWER UMTE0:4EOpA MAX.O 11 YDC MAX INSTALL CONTACT 0.ABUNE DEVICES PER ALL W ETIE SWAIN IS SURE RASED AND POWER LAMED MANLF4CTU ER'S INSTALLATION PRITRUCTIONS. 2-Wire Initiating Circuit Configuration, NFPA Style B TO NEXT ' FROM PANEL OR DEVICE \ /a PREVIOUS DEVICE MONITOR 0 , ANY NUMBER OF IL LISTED CONTACT MODULE 0 , NA AD CLOSURE DEVICES MAY BE USED DO NOT MIX ` « CONNECT MODULES TO LISTED comek TeLE FIRE ALARM INRA*3,SUPERVISORY,OR 6 Q 4 $ $ NOTFER CONTROL PANELS ONLY SECURITY DEVICES ON THE SAME MODULE. . i •O e1_. ni ', i i EOL RESISTOR IS 111110V1 a I INTERNAL A R♦ AKA TERMNALS t 60 Pm ow INSTALL CONTACT CLOSURE DEVICES PER ALL WIRING SHOWN IS SUPERVISED AND POWER UNITED MANUFACTURER'S INSTALLATION INSTRUCTIONS, 4-Wire Initiating Circuit Configuration, NFPA Style D Standby Current: Environmental 400 pA max @ 24 VDC (one communication every 5 Operating Temperature: 32°F - 120°F (0°C -49°C) sec with 47K EOL) Humidity: 10% -93% non-condensing 550 pA max @ 24 VDC (one communication every 5 sec with EOL <1K) Ordering Information 5.5 mA(with LED latched on) SK-Monitor Monitoring Module LED Current: 5.5 mA (with LED latched on)End-of-Line Resistance: 47K S2 Accessories Initiating Device Circuit Wiring Resistance: 1,500 S2 max SMB500 4" Square Surface Mount Electrical SLC Loop Resistance: 40 S2 max. Box it This document is not intended to be used for installation purposes.We try to SILENT Assembled in USA keep our product information up-to-date and accurate.We cannot cover all Ni KNIGHT specific applications or anticipate all requirements.All specifications are subject to change without notice.For more information,contact Silent Knight 12 FORM#350131 Rev E Clintonville Road, Northford, CT 06472-1610 Phone: (800)328-0103, Fax: (203) ©2013 Honeywell International Inc. by Honeywell 484-7118. For Technical Support, Please call 8200-446-6444. www.silentknight.com SILENT SK-Relay KNIGHT by Honeywell Intelligent Relay Module The SK-Relay Module is intended for use in intelligent, two-wire systems where the individual address of each module is selected using the built in rotary switches. For more information about the IntelliKnight system, or to locate you nearest source, please call 800-328-0103. Description The SK-Relay is an addressable relay module for use with Silent Knight IntelliKnight series fire alarm control panels (FACPs). The SK-Relay allows a Silent Knight FACP to switch discrete contacts by code command. The relay contains two f • "�� � ,r isolated sets of Form C contacts, which operate as a DPDT switch. No supervision is provided for the notification appliance circuit. The SK-Relay contacts can be used for virtually any normally open or normally closed application. Each SK- SK-Relay Relay is programmed with a unique signaling line circuit (SLC) loop address. When an event occurs that controls the Installation SK-Relay, the relay is triggered by the FACP. The SK-Relay mounts directly into a 4" square Features electrical box. The box must have a minimum • Two sets of Form C contacts depth of 2-1/8". A surface mount electrical box (System Sensor® PN SMB500) is available from • Rotary address switches for fast installation Silent Knight • Contacts are rated for a variety of amps (see Specifications) Compatibility • Panel controlled status LED that flashes green in normal The SK-Relay is compatible with the following IntelliKnight FACP's: state and is solid red in alarm 5820XL • Relay programming is completely flexible—can be mapped 5820XL-EVS to zone conditions 5808 5700 • Polling LED visible through the cover plate 5600 (Rev 2.0 or higher) • Attractive ivory cover plate • SEMS screws for easy wiring • UL Listed Model SK-Relay Intelligent Relay Module • To Next Device - ill If Any Wiring to Terminals 3—9 is Not Power + 4 Limited,the CB500 Barrier is Required.The CB500 Includes a Non-Power Limited Label, n n Which Must Be Placed Over the Power Limited e N Terminal Information on the Name Plate Label. Qo ° 00 Relay Common 2 • .fin. • ■ Normally Closed 2 • 1. I V Normally Open 2 ',a'• 2 10 Relay Common 1 • - From Compatible FACP Normally Closed 1 :ti • % 4 iw i + or Previous Device Module Does Not Supervise (Z c °m 0 Normally Open 1 Controlled Circuits w !1 U U Wiring the SK-Relay Module Specifications End-of-Line Resistance: not used Physical Standby Current: 300 pA max @ 24 VDC (one Height: 4.65" communication every 5 sec with LED enabled) Width: 4.25" LED Current: 5.5 mA(with LED latched on) Depth: 1.1" SLC Loop Resistance: 40b2 max. Shipping Weight: 6.3 oz (196 g) Relay Contact Ratings Electrical 3.0A @ 30 VDC resistive Operating Voltage: 15—32 VDC 0.9A @ 110 VDC resistive Current Draw: 6.5 mA max (LED on) 0.9A @ 125 VAC resistive Operating Current: 0.5A @ 125 VAC inductive (PF = .35) 230 pA(LED flashing) direct poll 0.7A @ 75 VAC inductive (PF = .35) 255 pA(LED flashing) group poll SILENT This document is not intended to be used for installation purposes.We try MADE IN AMERICA `j KNIGHT to keep our product information up-to-date and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are FORM#350127 Rev D subject to change without notice. For more information,contact Silent by Honeywell Knight 12 Clintonville Road, Northford, CT 06472-1610 Phone: ©2013 Honeywell International Inc. (800)328-0103, Fax: (203)484-7118. For Technical Support, Please Call 800-446-6444. www.silentknight.com aes-corp.corn CORPORATION "' :" Wireless Fire Alarm Communicators for AES-lntelliNet 788E-C Series FEATURES Advanced Wireless Alarm Monitoring • UL listed commercial fire As expensive dedicated landlines, required alarm applications. • ULC S 559 l ULC S 304 for ULC 5 559 compliance disappear, and • Direct reporting to AES the future of GSM for alarm transmission receiver across AES-tntel6Nrt becomes increasingly uncertain,the AES mesh radio network Each Subscriber acts as lrrtelliNet mesh radio network continues to • transmitter/receiver/repeater offer unmatched reliability and speed in • Simple and fast activation _ - • delivering wireless alarm signals to a central on network Ft • • On board status LEDs for R.• station without any third-party fees or easy setup -" ii' reliance on networks operated by companies • 8 programmable zone F . � outside the alarm industry.The 7788F C 'Easyy programming via AES snputs "= Series Subscribers provide the wireless • handheld programmer or PC as communications link between the fire alarm • Easy programming via AES r'Y ' panel and the central station receiver. Ideal handheld programmer or PC Rugged• metal housing ideal for most commercial fire alarm applications, for any commercial fire each 778SF-C Series Subscriber is housed alarm application in a full-sized,red, locked steel cabinet and • Nattowband compliant supports a range of alarm panel inputs, including EOL fire, EOL supervised,and direct MODELS voltage from the panel (non-fire applications). 7788F/7744F•ULP WITH AES•1NTf11JPRO FIRE ALSO INCLUDES SUpCrtttSed Oreratiofi. • AES-fntelliPro Are transmits AES Subscribers offer fully-supervised operation that includes monitoring of full alarm data from virtually operating power(both primary AC and battery back-up) and the connection to any fire alarm panel digital the mesh radio network. Each subscriber"checks-in"with the AES central station communicator • Alarm format support for receiver at least once every 24 hours. The supervision check-in time can be set to Contact ID.Pulse,as well as as often as needed for the application, as appropriate for the network.. Because Bosch Modem Ile and the central station operates the wireless network_ there is no additional cost for air Modem Ilia • Easy installation in AES time to transmit supervisory signals. subscriber • Operates in applications with or without a phone line `ZrC (DI Us ii S ! = i k Net( It: LISTED NFPN `!' HOW TO ORDER Full Data Reporting from Alarm Panel Digital Dialer Model Descriptioil Model 7788F-C-ULP comes equipped with an AES-fateitiPro Fire Full Data Module(AES 7744F 8 Zone Fire Alarm Subscriber 7794)which enables reporting of full alarm data captured from the alarm panel's digital communicator. AES intelliPro Fire supports most alarm communication formats 7788FC-ULP 7744F Fire Alarm including Contact ID, Pulse, as well as Etosch Modem Ile and Modem IIla2(when Subscriber with AES-MteiliPror Fire converted to Contact ID format). full data module Optional Accessories Technical Specifications 7788F-C Series Subscriber 71141E Subscriber Handheld Dimensions Storage Temperature Programmer •13.25'H x 8.5'W x 4.3'D •-10'to 60'C(14'to 140°F) 7794 AES-intelfi➢ra Fire Full Data (34cm H x 21.5cm W x tiem DJ Relative Humidity Module Weight •0 to 85%RHC,.Non Condensing 1640-C Plug-in Transformer • Approx.7 pounds 13 2 kilograms) 16.5VAC,40VA excludes battery 7794 AES-Prate) Pre Fire Radio Frequency Packaged with 77138F-C-ULP •Standard Frequency Range:450,476MHz Input/Output Connections tothers available In 400.512MHz range, •RJ11 connection to AES subscriber for mnduie Established in 1974•AES •Output Power-2 Watts data and power Corporation empowers •RJ11 connector for Handheld Programmer/PC Antenna programming companies to grow profitable •included 2.5 db tamper resistant antenna •RJ3IX Telco connections-T and R both In eat out alarm monitoring businesses, mounts on enclosure via terminal strip and R145 and government agencies to •Multiple remote antenna options available •Alarm Panel digital communicator T and R both enhance security anywhere Power Input In and out via termina strip and RJ45 in the world. ByprovidingP -Trouble output Form C relay detects if • 16.5VAC,4011A transformer(not included) the industry's only patented (ATC-Frost FPS 401 Aber Is off the network 6) operator-owned and controlled private wireless mesh networks, Backup Battery Alarm Formats AES ensures superior reliability, •Will charge 12V battery up to 7_5 AM_Requires •Support for Contact ID and Pulse formats as well low TCO and optimal RMR while 12V©C 7-5 AM battery fee UL 864 as Modem Ile and Modem ilia?converted to CID reducing dependence on service Stu provider infrastructures. Alarm Signal Inputs(subscriber) -2.8 x 5.0 Inches(7.1cnn x 12.7cm) The company's fl shi '7788F-8 Ind elduatty programmable tones p •7744E-4 Indleiduaiy programmable tones and Power Requirements 4E5-inre liNet systems are 4 reverse polarity Inputs •12 VDC nominal•primary and backup power deployed in over a half million provided by the AES 7788F-C or other Subscriber locations worldwide. ULC Standards •CAN/ULC S 559.04 •CAN/9JLC S 304 Antenna Cut/Communication Trouble Output •Form C relay;fail secure;rated for 24 VDC 1A resistive Reset Button •Located on main circuit board. Operating Temperature •0°to50°C(32°to122°f) For more information, go to www.aes-corp.com or call (800) 237-6387 or contact us at salestaes-corp.corn C Copyright 2014 AES Corporation I AES.mtat!Net is a registered trademark of ASS Co-aceatiol