Report OFFICE COPY FIRE ALARM SYSTEM —FACP REPLACEMENT SUBMITTAL GUIDE RECEIVED AUG 31 Z020 * DTh OF TIGARD BUILDING DIVISION TTSD - Charles F. Tigard Elementary 12855 SW Grant St. Tigard, OR 97223 OFFICE COPY CITY OF TIGARD,_, REVIEWED FOR LODE COMPLIANCE Approved: I OTC: ( j Permit#: F P.S',1.0r4.0 00 0 Address: y A SK- 4S rn�tr,`r ,s Suite #: By: 1 Date: q,kc'p c ''Io: fa s JOHN AMRCHETTE VALIDITY OF PEF:. '3 a THE ISSUANCE OF A PFI . T -n BASED ON CONSTRUCTI N DOCUMENTS AND OTiE Prepared By: DATA SHALL NOT PREV J'- r THE CODE Of FIC AL F':r,:M, PERFORMANCE REQUIRING THE CORRECTION SYSTEMS INTEGRATION OF ERRORS. OSSC 105.4 7324 SW Durham Road Portland, Oregon 97224 PLEASE PROVIDE info@psintegrated.com COMPLETED NFPA 72 (503) 641-2222 Phone RECORD OF (503) 641-1464 Fax COMPLETION AT FINAL INSPECTION 8/11/2020 Scope of Work: FACP replacement at TTSD—Charles F.Tigard Elementary c 5 �Sf 9 St Vincent Depaul-Tigard El Guajillo TO,. Tigardville Adult 13 Foster Care e P' a Burgerville9 5i. 12855 Southwest 9 0 *Grant Avenue Walnut Market 9 Delivery Astro di i Uni gli Broadway Rose Kids Campus v- 7 Theatre Company '4? ,g 9 6 9 9 9 Massage Mr Hookah Papa John's Pizza Temporarily closed takeout-Delivery cos P 9 9 Natural Grocers Sanchez Ta ueria Orchard ' O'Reilly Auto Parts 4 to n Auto parts store YPanaderia t1 akc wl f c Q 3. , Taco Del Sol 0 s sh- a m Takeout.Delivery �C F`04 No � L" S Google Papa Murphy's i Take N,Bake Pizza Map data 52020 Google United Stases Terms Send feedback 200fti Notes: 1. Scope includes replacing the existing FACP with a new 5820XL fire alarm control panel and the existing FAA with a compatible 5860R annunciator. 2. All input and output operations from the existing system will remain. 3. All filed devices; detectors, pull stations, power supplies and notification will remain. 4. There are no customer supplied plans of the fire alarm system. A 2020 Fire Alarm and Life Safety System Inspection Certificate is included detailing the complete system. . FACP location. isli floor Main Office in Work Room. Nt 102 I las ij A i L..........-...-L.....-......._.Li ( II s WEIN& i 1 100 1 ,_ ... ....n... ,,,, cFr Elementary • it,. ‘107 TO SCA:9 & i Jos Ito r 1 •0 IN '' , 1 '.. •• - 7..? rat,., 1:.1) .1 ,I . i tiyi fp- „ i It ji astr. 1 i--...... VI r 11 . ,47 cit,. . 1 .,---8?: outside 0o-roma Nay Anse 1 ii r 1 I 1 113 L P !., 101 i ' 114 ii c a 1 eise .. „..r.,...„ . 1. . ... r -71 Y.- II: IC,110PI: CA, i,, FA-0, . . i a, li ,r V'--• r il-.....i.....) i .1 -. ',... ' 4 7,1......:‘ ' i '—' . SCP 1 1 ,t ,•_7_1 ,_ i: ..! ') '1--, J ry -71 •. 1 I • t."1:: 1 ttiart li F--• — t‘-- ;—- ----1 II .1."±...-...,.. _11 .....______ r ryt gi I I etr tt yw, mzoz.]�i;lq w7�1,t!I S; k4 I'� I�itrvwr s1 I cr717 I•cr ,,„ :,I4, I•i,,t. , e� iUP• ' ����.• tR.' OF tt i F.of. . . ��it .�. c��l S �+'� R. ► � 1�3`� a► v'���iu Rom, ► R.�l�► �`P R':�i �. Ci R� �R,e. R<y.I RF"^�:` R.. ► B►x a R.�. R�^1 w' u�. :• i=3 u to �.u ♦. �_tJ`1�.�►�:et+�:��i u u u Z u ��v .u►�. �i �u, S I Mr WA k R ' 44 r �' t Fire Alarm and Life Safety System -u ' Efi cI. ;. Inspection Certificate ,kl t oil vi ,itiog F or kvir 0.004 u�i R,:u TTSD - Charles F. Tigard z ms Elementary p~; � 12855 SW Grant St. ' "IP`I, t r,,•, Tigard, OR 97223 ''R ., -� v, s *,<.p , &TA' Rom^ u '��i Tested to NFPA 72 Standards ;„... g`'� _, :,,ipo , This Inspection was performed in accordance with applicable NFPA Standards. The subsequent pages y of this report provide performance measurements, listed ranges of acceptable results, and complete IN a documentation of the inspection. Whenever discrepancies exist between acceptable performance • ..� standards and actual test results, notes and/or recommended solutions have been proposed or provided t.•S for immediate review and approval. IV KA ..I, `.'"^p Inspection Date ��\a sP Jun 24, 2019 ► ...1,2 SDI 0.* F , pry' %,.. t4 WIA t t� g Building:TTSD-Charles F.Tigard Elementary Company:Performance Systems Integration,LLC. -Portland `�" P' 3 Contact:Maryann Escriva Contact:Jordan Murrer � ���r u► yru/ Title:Facilites Director Title: Inspector t�ry ti. NP :''fu4 iv,.r ,u/u u►,I•SDI�'ia�tyiN a,it- I.iLyI•it;Ilt�,7rit�lri raft • vita� u I 1 I•i;I -Tl-li �t� tr I�,i/itr�5171S1ir� , part�:jubry►:,u y►ar au► '''ir Vli, :> .t:tu/� ' : u► i u►Ltiiut:.u► ' ►�.YuCV t./kati,—s s:r 1 i Executive Summary Generated by:BuildingReports.com Building Information Building: TTSD - Charles F. Tigard Elementary Contact: Maryann Escriva Address: 12855 SW Grant St. Phone: 503-431-4049 Address: Fax: City/State/Zip: Tigard, OR 97223 Mobile: 971-563-1605 Country: United States of America Email: mescriva@ttsd.kl2.or.us Inspection Performed By Company: Performance Systems Integration, LLC. Inspector:Jordan Murrer Portland Address: 7324 SW Durham Road Phone: 503-641-2222 Address: Fax: City/State/Zip: Portland, Oregon 97224 Mobile: Country: United States of America Email:jordanm@psintegrated.com System Control Unit Manufacturer: Silent Knight Inspection Date: 06/24/2019 IDC Style: Model Number: IFP-1000 Install Date: 08/02/2010 SLC Style: Software Version: Version Date: 08/02/2010 NAC Style: Location: 1st Main Office in Work Room Current Protection: Monitoring Company: Phone: Account#: Central Station Signal Verification Type: Digital Radio Mfg: AES Model #: 7788F Test Time/Date: 6/24/19 9:36:39 AM Restore Time Type of Signal Signal Confirmation Notes Type: Alarm/Trouble/Supervisory Confirmed Time: Performance Systems Integration,LLC. -Portland 1 08/10/2020 Inspection Summary Total Items Serviced Passed Failed/Other Category Qty % Qty % Qty % Qty % Sound Test 2 0.97% 2 100.00% 2 100.00% 0 0% Control 12 5.80% 12 100.00% 12 100.00% 0 0% Auxiliary 6 2.90% 5 83.33% 5 100.00% 0 0% Monitor 1 0.48% 1 100.00% 1 100.00% 0 0% Initiating 18S 89.37% 184 99.46% 184 100.00% 0 0% Supervisory 1 0.48% 1 100.00% 1 100.00% 0 0% Totals 207 100% 205 99.03% !, 205 100.00% 0 0% Certification Company: Performance Systems Integration, LLC. - Building: TTSD - Charles F. Tigard Elementary Portland Inspector:Jordan Murrer Contact: Maryann Escriva Signed: Signed: Performance Systems Integration,LLC.-Portland 2 08/10/2020 Notes & Recommendations Generated by:RuildingReports.com Building: TTSD - Charles F. Tigard Control Panel: 1 - Silent Knight Elementary IFP-1000 The Notes&Recommendations Report details additional inspection notes made by the Inspectors during the course of the building inspection.Notes are grouped by Category. ScanlD I Note Device Type Location Comment Auxiliary 48296337 1 Fire Barrier 1st At hall by elevator Tested by another company Initiating 08713739 2 Heat Detector 1st At Gymnasium Storage Room Could not locate device 24357856 3 Smoke Detector 2nd At Custodian Room 4 In Electrical Room 2 Passed Device didn't seem to have power tkt 361651 replaced smoke det. JB sides 2/7/19 Performance Systems Integration,LLC.-Portland 3 08/10/2020 Inspection & Testing Generated by:BuildingReports.com Building: TTSD - Charles F. Tigard Control Panel: 1 - Silent Knight Elementary UT-1000 The Inspection &Testing section lists all of the items inspected in your building. Items are grouped by Passed or Failed/Other.Items are listed by Category. Each item includes the services performed, and the time&date at which testing occurred. J Device Type , Location Service ; Time Date Passed Auxiliary Elevator 1st At Elevator Machine Room Tested 12:50:54 PM 06/24/2019 Elevator 1st At Elevator Machine Room Tested 12:50:59 PM 06/24/2019 Elevator 1st At Elevator Machine Room Tested 12:51:00 PM 06/24/2019 Elevator 1st At Elevator Machine Room Tested 12:51:01 PM 06/24/2019 Elevator 1st At Elevator Machine Room Tested 12.51:03 PM 06/24/2019 Control Annunciator 1st At Main Entrance Tested 9:41:00 AM 06/24/2019 Battery 1st At Computer Lab in MDF Room Tested 12:37:13 PM 06/24/2019 Battery 1st At Main Office Work Room Tested 9:31:04 AM 06/24/2019 Battery 1st At Main Office Work Room Tested 9:31:42 AM 06/24/2019 Battery 1st At Main Office Work Room in radio Tested 9:32:29 AM 06/24/2019 Battery 1st Computer Lab in MDF Room Tested 12:34:53 PM 06/24/2019 Battery 2nd At IDF Room Tested 12:07:19 PM 06/24/2019 Battery 2nd At IDF Room Tested 12:07:37 PM 06/24/2019 Communicator 1st Main Office in Work Room Tested 9:36:39 AM 06/24/2019 Control Panel 1st Main Office in Work Room Tested 9:29:55 AM 06/24/2019 Expander Panel 1st At Computer Lab in MDF Room Tested 12:34:46 PM 06/24/2019 Expander Panel 2nd At IDF Room Tested 12:03:39 PM 06/24/2019 Initiating Heat Detector 1st At Cafeteria Storage Room 2 Tested 1:08:08 PM 06/24/2019 Heat Detector 1st At Cafeteria Storage Room 3 Tested 1:16:56 PM 06/24/2019 Heat Detector 1st At Cafeteria Storage Room 4 Tested 1:17:00 PM 06/24/2019 Heat Detector 1st At Custodian Room 5 Near Stage Tested 1:21:56 PM 06/24/2019 Heat Detector 1st At Elevator Machine Room Tested 12:50:57 PM 06/24/2019 Heat Detector 1st At Gymnasium Storage Room Tested 1:24:56 PM 06/24/2019 Heat Detector 1st At Kitchen Tested 1:16:48 PM 06/24/2019 Heat Detector 1st At Kitchen Tested 1:16:51 PM 06/24/2019 Heat Detector 2nd At Boiler Room Tested 1:04:39 PM 06/24/2019 Pull Station 1st At Cafeteria Exit Near Kitchen Tested 12:28:13 PM 06/24/2019 Pull Station 1st At Gymnasium Exit Tested 10:06:48 AM 06/24/2019 Pull Station 1st At Gymnasium Exit Tested 10:08:01 AM 06/24/2019 Pull Station 1st At Hallway Exit Near Elevator Lobby Tested t o:22:02 AM 06/24/2019 Pull Station 1st At Hallway Exit Near Stage Tested 12:26:31 PM 06/24/2019 Pull Station 1st At Hallway Exit Near Stairwell Tested 10:47:56 AM 06/24/2019 Pull Station 1st At Hallway Exit Near Stairwell Tested 1 a:58:04 AM 06/24/2019 Pull Station 1st At Hallway Exit near Gym Tested 10:05:30 AM 06/24/2019 Performance Systems Integration,LLC.-Portland 4 08/10/2020 Device Type Location Service Time Date Passed Pull Station 1st At Hallway Exit Near Music Room Tested 10:03:23 AM 06/24/2019 Pull Station 1st At Kitchen Exit Tested 12:28:46 PM 06/24/2019 Pull Station 1st At Library Exit Tested 9:57:28 AM 06/24/2019 Pull Station 1st At Main Entrance Tested 9:42:09 AM 06/24/2019 Pull Station 1st At Main Hallway Exit Near Custodian Room Tested 9:39:45 AM 06/24/2019 3 Pull Station 1st At Main Office Staff Lounge Exit Tested 9:36:10 AM 06/24/2019 Pull Station 1st At Music Room Exit Tested 12:18:24 PM 06/24/2019 Pull Station 2nd At Stairwell Exit Near Elevator Lobby Tested 11:15:31 AM 06/24/2019 Pull Station 2nd At Stairwell Exit Tested t 1:41:03 AM 06/24/2019 Pull Station 2nd At Stairwell Exit Tested 11:51:07 AM 06/24/2019 Smoke Detector 1st At Boy's Restroom Near Classroom 101 Tested/Cleaned 10:29:55 AM 06/24/2019 Smoke Detector 1st At Boy's Restroom Near Classroom 106 Tested/Cleaned 10:48:56 AM 06/24/2019 Smoke Detector 1st At Boy's Restroom Near Classroom 114 Tested/Cleaned 11:20:52 AM 06/24/2019 Smoke Detector 1st At Boy's Restroom Near Gymnasium Tested/Cleaned 10:09:43 AM 06/24/2019 Smoke Detector 1st At Boy's Restroom Custodian Room 1 Near Tested/Cleaned 11:22:25 AM 06/24/2019 Classroom 101 Smoke Detector 1st At Cafeteria Tested/Cleaned 10:11:07AM 06/24/2019 Smoke Detector 1st At Cafeteria Tested/Cleaned 10:12:45 AM 06/24/2019 Smoke Detector 1st At Cafeteria Tested/Cleaned 10:12:52 AM 06/24/2019 Smoke Detector 1st At Cafeteria Tested/Cleaned 10:13:29 AM 06/24/2019 Smoke Detector 1st At Classroom 101 Tested/Cleaned 11:06:25 AM 06/24/2019 Smoke Detector 1st At Classroom 101 Tested/Cleaned 11:06:41 AM 06/24/2019 Smoke Detector 1st At Classroom 102 Tested/Cleaned 11:04:27 AM 06/24/2019 Smoke Detector 1st At Classroom 102 Tested/Cleaned 11:05:25 AM 06/24/2019 Smoke Detector 1st At Classroom 103 Tested/Cleaned 11:02:49 AM 06/24/2019 Smoke Detector 1st At Classroom 103 Tested/Cleaned 11:03:37 AM 06/24/2019 Smoke Detector 1st At Classroom 104 Tested/Cleaned 11:00:40 AM 06/24/2019 Smoke Detector 1st At Classroom 104 Tested/Cleaned 11:01:31 AM 06/24/2019 Smoke Detector 1st At Classroom 105 Tested/Cleaned 10:59:01 AM 06/24/2019 Smoke Detector 1st At Classroom 105 Tested/Cleaned 11:00:07 AM 06/24/2019 Smoke Detector 1st At Classroom 106 Tested/Cleaned 10:49:17 AM 06/24/2019 Smoke Detector 1st At Classroom 106 Tested/Cleaned 10:49:28 AM 06/24/2019 Smoke Detector 1st At Classroom 107 Tested/Cleaned 10:51:08 AM 06/24/2019 Smoke Detector 1st At Classroom 107 Tested/Cleaned 10:51:26 AM 06/24/2019 Smoke Detector 1st At Classroom 108 Tested/Cleaned 10:53:28 AM 06/24/2019 Smoke Detector 1st At Classroom 108 Tested/Cleaned 10:54:41 AM 06/24/2019 Smoke Detector 1st At Classroom 109 Tested/Cleaned 10:55:35 AM 06/24/2019 Smoke Detector 1st At Classroom 109 Tested/Cleaned 10:56:13 AM 06/24/2019 Smoke Detector 1st At Classroom 110 Tested/Cleaned 10:44:46 AM 06/24/2019 Smoke Detector 1st At Classroom 110 Tested/Cleaned 10:45:15 AM 06/24/2019 Smoke Detector 1st At Classroom 111 Tested/Cleaned 10:43:12 AM 06/24/2019 Smoke Detector 1st At Classroom 111 Tested/Cleaned 10:43:47 AM 06/24/2019 Smoke Detector 1st At Classroom 112 Tested/Cleaned 10:42:15 AM 06/24/2019 Smoke Detector 1st At Classroom 112 Tested/Cleaned 10:42:28 AM 06/24/2019 Smoke Detector 1st At Classroom 113 Tested/Cleaned 10:37:43 AM 06/24/2019 Smoke Detector 1st At Classroom 113 Tested/Cleaned 10:38:02 AM 06/24/2019 Smoke Detector 1st At Classroom 114 Office 5 Tested/Cleaned 10:27:28 AM 06/24/2019 Smoke Detector 1st At Classroom 114 Restroom Tested/Cleaned t 0:28:23 AM 06/24/2019 Smoke Detector 1st At Classroom 114 Tested/Cleaned 10:24:55 AM 06/24/2019 Performance Systems Integration,LLC.-Portland 5 08/10/2020 Device Type Location 1 Service Time Date Passed Smoke Detector 1st At Classroom 114 Tested/Cleaned 10:26:03 AM 06/24/2019 Smoke Detector 1st At Computer Lab in MDF Room Tested/Cleaned 12:39:31 PM 06/24/2019 Smoke Detector 1st At Computer Lab Near Library Tested/Cleaned 9:59:22 AM 06/24/2019 Smoke Detector 1st At Counseling Office 1 Tested/Cleaned 10:35:44 AM 06/24/2019 Smoke Detector 1st At Custodian Room 3 Near Elevator Machine Tested/Cleaned 12:39:21 PM 06/24/2019 Room Smoke Detector 1st At Electrical 1 Room Tested/Cleaned 12:39:41 PM 06/24/2019 Smoke Detector 1st At Elevator Lobby Tested/Cleaned 12:50:15 PM 06/24/2019 ' Smoke Detector 1st At Elevator Machine Room Tested/Cleaned 12:50:55 PM 06/24/2019 Smoke Detector 1st At Girl's Restroom Near Classroom 105 Tested/Cleaned 10:33:59 AM 06/24/2019 Smoke Detector 1st At Girl's Restroom Near Classroom 108 Tested/Cleaned 10:56:53 AM 06/24/2019 Smoke Detector 1st At Girl's Restroom Near Classroom 110 Tested/Cleaned 10:45:46AM 06/24/2019 Smoke Detector 1st At Girl's Restroom Near Gymnasium Tested/Cleaned 10:09:27 AM 06/24/2019 Smoke Detector 1st At Gym Tested/Cleaned 10:16:50AM 06/24/2019 Smoke Detector 1st At Gym Tested/Cleaned 10:16:54 AM 06/24/2019 Smoke Detector 1st At Gym Tested/Cleaned 10:17:01 AM 06/24/2019 Smoke Detector 1st At Gym Tested/Cleaned 10:17:23 AM 06/24/2019 Smoke Detector 1st At Gym Tested/Cleaned 10:17:41 AM 06/24/2019 Smoke Detector 1st At Gym Tested/Cleaned 10:17:47 AM 06/24/2019 Smoke Detector 1st At Hallway Near Classroom 101 Tested/Cleaned 10:29:11 AM 06/24/2019 Smoke Detector 1st At Hallway Near Office 2 Tested/Cleaned 10:35:01 AM 06/24/2019 Smoke Detector 1st At Hallway Exit Near Stage Tested/Cleaned 11:10:57 AM 06/24/2019 Smoke Detector 1st At Kitchen Storage Tested/Cleaned 12:26:41 PM 06/24/2019 Smoke Detector 1st At Library Tested/Cleaned 9:56:06 AM 06/24/2019 Smoke Detector 1st At Library Tested/Cleaned 9:59:01 AM 06/24/2019 Smoke Detector 1st At Library Tested/Cleaned 9:59:04 AM 06/24/2019 Smoke Detector 1st At Library Office Tested/Cleaned 10:00:35 AM 06/24/2019 Smoke Detector 1st At Main Entrance Tested/Cleaned 11:10:43 AM 06/24/2019 Smoke Detector 1st At Main Hallway Near Cafeteria Tested/Cleaned 10:03:50AM 06/24/2019 Smoke Detector 1st At Main Hallway Near Gym Tested/Cleaned 11:10:37 AM 06/24/2019 Smoke Detector 1st At Main Hallway Near Library Tested/Cleaned 10:01:33 AM 06/24/2019 Smoke Detector 1st At Main Hallway Near Main Office Tested/Cleaned 9:39:51 AM 06/24/2019 Smoke Detector 1st At Main Hallway Near Main Office Tested/Cleaned 9:40:44 AM 06/24/2019 Smoke Detector 1st At Main Hallway Near Music Room Tested/Cleaned 10:02:17 AM 06/24/2019 Smoke Detector 1st At Main Hallway Near Office 2 Tested/Cleaned 10:46:30 AM 06/24/2019 Smoke Detector 1st At Main Hallway Near Stairwell Tested/Cleaned 10:47:01 AM 06/24/2019 Smoke Detector 1st At Main Office Conference Room Tested/Cleaned 9:51:43 AM 06/24/2019 Smoke Detector 1st At Main Office Health Room Tested/Cleaned 9:43:56 AM 06/24/2019 Smoke Detector 1st At Main Office Health Room Restroom Tested/Cleaned 9:52:21 AM 06/24/2019 Smoke Detector 1st At Main Office Office 1 Tested/Cleaned 9:51:55 AM 06/24/2019 Smoke Detector 1st At Main Office Restroom Tested/Cleaned 9:37:35 AM 06/24/2019 Smoke Detector 1st At Main Office Staff Lounge Tested/Cleaned 11:11:05 AM 06/24/2019 Smoke Detector 1st At Main Office Tested/Cleaned 9:43:16 AM 06/24/2019 Smoke Detector 1st At Main Office Tested/Cleaned 11:21:25 AM 06/24/2019 Smoke Detector 1st At Main Office Workroom Tested/Cleaned 9:38:03 AM 06/24/2019 Smoke Detector 1st At Music Room Tested/Cleaned 12:18:35 PM 06/24/2019 Smoke Detector 1st At Music Room Tested/Cleaned 12:18:46 PM 06/24/2019 Smoke Detector 1st At Office 2 Near Counseling Office Tested/Cleaned 11:21:03 AM 06/24/2019 Smoke Detector 1st At PE Office Tested/Cleaned 12:32:25 PM 06/24/2019 Smoke Detector 1st At Pod Near Classroom 102 Tested/Cleaned 10:31:46 AM 06/24/2019 Performance Systems Integration,LLC.-Portland 6 08/10/2020 Device T .e Location I Service Time Date Passed Smoke Detector 1st At Pod Near Classroom 103 Tested/Cleaned 10:32:10 AM 06/24/2019 Smoke Detector 1st At Pod Near Classroom 105 Tested/Cleaned 10:32:52 AM 06/24/2019 Smoke Detector 1st At Pod Near Classroom 107 Tested/Cleaned 10:48:32 AM 06/24/2019 Smoke Detector 1st At Pod Near Classroom 108 Tested/Cleaned 10:52:30 AM 06/24/2019 Smoke Detector 1st At Pod Near Classroom 110 Tested/Cleaned 10:40:27 AM 06/24/2019 Smoke Detector 1st At Pod Near Classroom 112 Tested/Cleaned 10:39:21 AM 06/24/2019 Smoke Detector 1st At Pod Near Classroom 114 Tested/Cleaned 10:37:10 AM 06/24/2019 Smoke Detector 1st At Principal's Office Tested/Cleaned 11:21:21 AM 06/24/2019 Smoke Detector 1st At Staff Restroom Near Office 2 Tested/Cleaned 11:20:58 AM 06/24/2019 Smoke Detector 1st At Staff Restroom Near Stairwell Tested/Cleaned 11:21:10 AM 06/24/2019 Smoke Detector 1st At Staff Restroom Near Kitchen Tested/Cleaned 10:15:57 AM 06/24/2019 Smoke Detector 1st At Stage Tested/Cleaned 10:17:18 AM 06/24/2019 Smoke Detector 1st At Stairwell Tested/Cleaned 11:21:53 AM 06/24/2019 Smoke Detector 1st At Stairwell Tested/Cleaned 11:21:57 AM 06/24/2019 Smoke Detector 1st At Storage 1 By Stage Tested/Cleaned 12:20:06 PM 06/24/2019 Smoke Detector 2nd At Boy's Restroom Near Classroom 201 Tested/Cleaned 11:36:58 AM 06/24/2019 Smoke Detector 2nd At Boy's Restroom Near Classroom 206 Tested/Cleaned 11:45:29 AM 06/24/2019 Smoke Detector 2nd At Boy's Restroom Near Classroom 214 Tested/Cleaned 11:18:51 AM 06/24/2019 Smoke Detector 2nd At Boy's Restroom Custodian Room 2 Near Tested/Cleaned 12:10:07 PM 06/24/2019 Classroom 201 Smoke Detector 2nd At Classroom 201 Tested/Cleaned 11:36:01 AM 06/24/2019 Smoke Detector 2nd At Classroom 201 Tested/Cleaned 11:36:24 AM 06/24/2019 Smoke Detector 2nd At Classroom 202 Tested/Cleaned 11:34:47 AM 06/24/2019 Smoke Detector 2nd At Classroom 202 Tested/Cleaned 11:35:02 AM 06/24/2019 Smoke Detector 2nd At Classroom 203 Tested/Cleaned 11:33:26 AM 06/24/2019 Smoke Detector 2nd At Classroom 203 Tested/Cleaned 11:33:57 AM 06/24/2019 Smoke Detector 2nd At Classroom 204 Tested/Cleaned 11:31:39 AM 06/24/2019 Smoke Detector 2nd At Classroom 204 Tested/Cleaned 11:31:51 AM 06/24/2019 Smoke Detector 2nd At Classroom 205 Tested/Cleaned 11:28:48 AM 06/24/2019 Smoke Detector 2nd At Classroom 205 Tested/Cleaned 11:29:04 AM 06/24/2019 Smoke Detector 2nd At Classroom 206 Tested/Cleaned 11:49:03 AM 06/24/2019 Smoke Detector 2nd At Classroom 206 Tested/Cleaned 11:49:18 AM 06/24/2019 Smoke Detector 2nd At Classroom 207 Tested/Cleaned 11:47:35 AM 06/24/2019 Smoke Detector 2nd At Classroom 207 Tested/Cleaned 11:47:58 AM 06/24/2019 Smoke Detector 2nd At Classroom 208 Tested/Cleaned 11:43:53 AM 06/24/2019 Smoke Detector 2nd At Classroom 208 Tested/Cleaned 11:44:22 AM 06/24/2019 Smoke Detector 2nd At Classroom 209 Tested/Cleaned 11:42:27 AM 06/24/2019 Smoke Detector 2nd At Classroom 209 Tested/Cleaned 11:42:42 AM 06/24/2019 Smoke Detector 2nd At Classroom 210 Tested/Cleaned 11:25:40 AM 06/24/2019 Smoke Detector 2nd At Classroom 210 Tested/Cleaned 11:25:54 AM 06/24/2019 Smoke Detector 2nd At Classroom 211 Tested/Cleaned 11:24:13 AM 06/24/2019 Smoke Detector 2nd At Classroom 211 Tested/Cleaned 11:24:49 AM 06/24/2019 Smoke Detector 2nd At Classroom 212 Tested/Cleaned 11:22:04 AM 06/24/2019 Smoke Detector 2nd At Classroom 212 Tested/Cleaned 11:22:46 AM 06/24/2019 Smoke Detector 2nd At Classroom 213 Tested/Cleaned 11:20:06 AM 06/24/2019 Smoke Detector 2nd At Classroom 213 Tested/Cleaned 11:20:29 AM 06/24/2019 Smoke Detector 2nd At Classroom 214 Tested/Cleaned 11:16:27 AM 06/24/2019 Smoke Detector 2nd At Classroom 214 Tested/Cleaned 11:19:35 AM 06/24/2019 Smoke Detector 2nd At Custodian 4 Elevator Lobby High Ceiling Tested/Cleaned 12:50:11 PM 06/24/2019 Smoke Detector 2nd At Custodian Room 4 In Electrical Room 2 Tested/Cleaned 12:15:44 PM 06/24/2019 Performance Systems Integration,LLC.-Portland 7 08/10/2020 Device Type Location I Service —1 Time FDate Passed Smoke Detector 2nd At Electrical 3 Tested/Cleaned 12:16.04 PM 06/24/2019 Smoke Detector 2nd At Elevator Lobby Tested/Cleaned 12:50:21 PM 06/24/2019 Smoke Detector 2nd At Girl's Restroom Near Classroom 205 Tested/Cleaned 1:28:24 AM 06/24/2019 Smoke Detector 2nd At Girl's Restroom Near Classroom 209 Tested/Cleaned 11:41:55 AM 06/24/2019 • • Smoke Detector 2nd At Girl's Restroom Near Classroom 210 Tested/Cleaned 11:26:47 AM 06/24/2019 Smoke Detector 2nd At Hallway Outside IDF Room Tested/Cleaned 11:40:01 AM 06/24/2019 Smoke Detector 2nd At Main Hallway Near Classroom 214 Tested/Cleaned 11:16:02 AM 06/24/2019 Smoke Detector 2nd At Main Hallway Near Office 3 Tested/Cleaned 11:39:06 AM 06/24/2019 Smoke Detector 2nd At Main Hallway Tested/Cleaned 11:27:44 AM 06/24/2019 Smoke Detector 2nd At Office 3 In Main Hallway Tested/Cleaned 11:50:07 AM 06/24/2019 Smoke Detector 2nd At Office 4 By Main Hallway Tested/Cleaned 11:37:57 AM 06/24/2019 Smoke Detector 2nd At Pod Near Classroom 201 Tested/Cleaned 11:50:02 AM 06/24/2019 Smoke Detector 2nd At Pod Near Classroom 203 Tested/Cleaned 11:32:32 AM 06/24/2019 • • Smoke Detector 2nd At Pod Near Classroom 205 Tested/Cleaned 11:30:39 AM 06/24/2019 • Smoke Detector 2nd At Pod Near Classroom 206 Tested/Cleaned 11:47:22 AM 06/24/2019 Smoke Detector 2nd At Pod Near Classroom 209 Tested/Cleaned 11:41:24 AM 06/24/2019 Smoke Detector 2nd At Pod Near Classroom 210 Tested/Cleaned 11:26:29 AM 06/24/2019 Smoke Detector 2nd At Pod Near Classroom 212 Tested/Cleaned 11:21:31 AM 06/24/2019 Smoke Detector 2nd At Pod Near Classroom 214 Tested/Cleaned 11:19:15 AM 06/24/2019 Smoke Detector 2nd At Staff Restroom By Main Hallway Tested/Cleaned 11:37:42 AM 06/24/2019 Smoke Detector 2nd At Hallway Between Boiler Room and Tested/Cleaned 12:21:34 PM 06/24/2019 Electrical 3 Monitor Monitoring 1st Main Office in Work Room Tested 9:35:34 AM 06/24/2019 Supervisory Tamper Switch 1st At Custodian Room 5 Near Stage Tested 12:57:25 PM 06/24/2019 Device Type Location Service Time Date Untested Auxiliary Fire Barrier 1st At hall by elevator Initiating Heat Detector 1st At Gymnasium Storage Room • Performance Systems Integration,LLC. -Portland 8 08/10/2020 Service Summary Generated by.•BuildingReports.com Building: TTSD - Charles F. Tigard Elementary The Service Summary section provides an overview of the services performed in this report. Device Type Service Quantity Passed Annunciator Tested 1 Battery Tested 7 Communicator Tested 1 Control Panel Tested 1 Elevator Tested 5 Expander Panel Tested 2 Heat Detector Tested 9 Monitoring Tested 1 Pull Station Tested 18 Smoke Detector Tested/Cleaned 157 Tamper Switch Tested 1 Total 203 Untested Fire Barrier 1 -- Heat Detector 1 Total 2 Grand Total 205 Performance Systems Integration,LLC.-Portland 9 08/10/2020 Auxiliary Functions Testing Generated by.BuildingReports.corn Building: TTSD Charles F. Tigard Control Panel: 1 - Silent Knight 1FP-1000 Elementary The Auxiliary Functions Testing section lists each of the ancillary items, systems, and emergency equipment that are controlled by the system control unit.Items are grouped by Passed or Failed/Other. The items are listed by device type, and a check box is provided to indicate if the test conducted was simulated. Location ; mment ScanlD i Simulated Passed Elevator Sign Off Log 1st At Elevator Machine Room Passed 20650209 ❑ Shunt Trip 1st At Elevator Machine Room Passed 20650211 lil Recall Alternate 1st At Elevator Machine Room Passed 20650212 ❑ Recall Primary 1st At Elevator Machine Room Passed 20650213 ❑ Fire Hat 1st At Elevator Machine Room Passed 20650210 ❑ Smoke Detector Elevator Recall 1st At Elevator Lobby Passed 0871 3653 Elevator Recall 1st At Elevator Machine Room Passed 20650206 Elevator Recall 2nd At Custodian 4 Elevator Lobby High Passed 20650214 Ceiling Elevator Recall 2nd At Elevator Lobby Passed 0871 3591 Untested Fire Barrier 1 st At hall by elevator 48296337 Performance Systems Integration,LLC.-Portland 10 08/10/2020 Sound and Visual Testing Generated by:BuildingReports.com Building: TTSD - Charles F. Tigard Elementary The Sound and Visual Testing section lists various points throughout your building where audible and visual alarm notification devices were tested. Any bar-coded audible and visual devices will appear in the Inspection and Testing section of this report. Items in this section are grouped by Passed or Failed/Other. Where specific decibel readings were recorded, they will appear under the ambient and alarm columns. The Voice column indicates whether the Sound Test Point passed the Voice Intelligibility requirements. The STI or Sound Transmission Index is shown if recorded. Ambient Alarm ' Intelligibility Sound Location at Comment y dB 4 dB Voice STI Test Passed Sound Test Points 1st Floor Passed ❑ 0001 2nd Floor Passed ❑ 0002 Performance Systems Integration,LLC.-Portland 11 08/10/2020 Buttery & Power Supply Testing Generated by:BuildingReports.com Building: TTSD - Charles F. Tigard Control Panel: 1 - Silent Knight Elementary IFP-1000 The Battery&Power Supply Testing section details the readings and measurements of batteries and power supplies used to provide power to the fire alarm and life safety systems.Items are grouped by Passed or Failed/Other. I _ Battery Rated Rated Pre Post Min Tested T .e Location Ah Volts Test Test Ah Ah ........____ Passed Sealed Lead Acid 1st Computer Lab in MDF 8 12 13.66 14.54 Room Sealed Lead Acid 1st At Computer Lab in MDF 8 12 13.58 14.54 Room Sealed Lead Acid 1st At Main Office Work Room 18 12 13.06 13.76 Sealed Lead Acid 1st At Main Office Work Room 18 12 13.23 14.1 5 Sealed Lead Acid 1st At Main Office Work Room 12 12 1 3.70 11.90 in radio Sealed Lead Acid 2nd At IDF Room 8 12 13.58 10.61 Sealed Lead Acid 2nd At IDF Room 8 12 13.82 14.54 Performance Systems Integration,LLC.-Portland 12 08/10/2020 Inventory & Warranty Report Generated by:BuildingReports.corn Building: TTSD Charles F. Tigard Control Panel: 1 - Silent Knight IFP-1000 • Xementary .t K , The Inventory & Warranty Report lists each of the devices and items that are included in your Inspection Report.A complete inventory count by device type and category is provided. Items installed within the last 90 days,within the last year, and devices installed for two years or more are grouped together for easy reference. Device or Type Category I % Ofilpventory Quantity Heat Detector Initiat ng 4.83% 10 Fire Barrier Auxiliary 0.48% 1 Control Panel Control 0.48% 1 Battery Control 3.38% 7 Pull Station Initiating 8.70% 18 Monitoring Monitor 0.48% 1 Communicator Control 0.48% 1 Smoke Detector Initiating 75.85% 157 Annunciator Control 0.48% 1 Expander Panel Control 0.97% 2 Elevator Auxiliary 2.42% 5 Tamper Switch Supervisory 0.48% 1 Sound Test Sound Test 0.97% 2 Qt Type y I Model # Description Install Date In Service - 1 Year to 2 Years Duracell Battery 2 DURA12-8F Sealed Lead Acid 06/03/2019 In Service - 3 Years to 5 Years EM24 Monitoring 1 R93810 Alarm/Trouble/Supervisory 06/29/2017 Power-Sonic Battery 1 PS-12180 NB Sealed Lead Acid 06/29/2017 Werker Battery 2 WKAl2-8F Sealed Lead Acid 10/10/2015 In Service - 5 Years s to o 10 Years Fire Barrier 1 06/24/201 5 Power-Sonic Battery 2 PS-12180 NB Sealed Lead Acid 06/23/201 5 In Service - 10 Years to 15 Years AES Communicator 1 7788F Digital Radio 08/02/2010 ALTERNATE Performance Systems Integration,LLC.-Portland 13 08/10/2020 Elevator 1 RECALL Recall Alternate 08/02/2010 FIRE Elevator 1 HAT Fire Hat 08/02/2010 Gruvlok Tamper Switch 1 Butterfly Valve 08/02/2010 PRIMARY Elevator 1 RECALL Recall Primary 08/02/2010 SHUNT Elevator 1 TRIP Shunt Trip 08/02/2010 SIGN-OFF Elevator 1 LOG Sign Off Log 08/02/2010 Silent Knight Annunciator 1 SK-5860 LED List 08/02/2010 Control Panel 1 IFP-1000 08/02/2010 Expander Panel 2 5499 08/02/2010 Heat Detector 10 SD505-AHS Rate-of-Rise 08/02/2010 Pull Station 18 SD500-PS Dual Action 08/02/2010 Smoke Detector 15 SD505-APS Photoelectric 08/02/2010 7 Performance Systems Integration,LLC.-Portland 14 08/10/2020 INTELLIKNIGHT FIRE ALARM CONTROL PANEL SILENT IntelliKnight® Model 5820XL KNIGHT Addressable Fire by Honeywell Alarm Control System The IntelliKnight System is the easy way to make the most of fire alarm technology. IntelliKnight 5820XL is the first fire alarm system to provide you with revolutionary value and performance in addressable sensing technology. The 5820XL FACP offers exclusive, built-in digital communication, distributed intelligent power, a modular design and an expanded, easy to use interface. Powerful features such as drift compensation and maintenance alert are delivered in this powerful FACP from Silent Knight. For more information about the 5820XL system, or to locate your nearest source, please call 800-328-0103. Description 5820XL is an intelligent addressable fire alarm control panel (FACP). The basic 5820XL system can be expanded by adding modules such as 5860 remote annunciator, 5815XL signalling line circuit expander, 5824 serial/parallel printer interface module (for printing system reports), and 5895XL intelligent power module. 5820XL supports SD or SK devices. 5820XL also features a powerful built-in dual line fire communicator that allows for reporting of all system activity to a remote monitoring location. Features • Built in support for 99 SK detectors and 99 SK modules, expandable to 396 SK detectors and 396 SK modules using System Sensor protocol • Built in support for 127 SD devices, expandable to 508 SD devices using the SD protocol. -„.. • Uses standard wire—no shielded or twisted pair required • Built-in digital communicator Model 5820XL • Central station reporting by point or by zone • Built-in synchronization for appliances from AMSECO®, • 6 amp power supply and maximum Gentex®, Faraday, System Sensor, and Wheelock® charging l cabinetapacity of cl amp hoursrequired cabinet enclosure is for • FlexputTm I/O circuits batteries in excess of 18 amp hours) • Supports Class B (Style 4) and Class A(Style 6) configuration • Programmable date setting for Daylight for SLC, SBUS, and Flexput circuits Saving Time • 13 pre-programmed output cadences (including ANSI-3.41) and 4 programmable outputs Installation • Built-in annunciator with 80-character LCD display The 5820XL can be surface or flush • RS-485 bus provides communication to system accessories mounted • Built-in RS-232 and USB interface for programming via PC • Built-in Form C trouble relay rated at 2.5 amps at 27.4 VDC Compatibility • Improvements in SKSS software deliver five times faster The 5820XL signal line circuit (SLC) uploads/downloads supports multiple device types of the same • Two built-in Form C programmable relays rated at 2.5 amps protocol: at 27.4 VDC • SK (System Sensor) • Plex-1 door option combines a dead front cabinet door with a SD clear window, limiting access to the panel while providing • single button operation of the reset and silence functions You cannot mix SD and SK SLC devices on a FACP. INTELLIKNIGHT FIRE ALARM CONTROL PANEL IntelliKnight Model 5820XL Addressable Fire Alarm Control Panel Indicator Lights 5820XL features a 6 amp power supply required to start a new system. The General Alarm (Red): Flashes when in and maximum battery charging built-in keypad and 5860 remote alarm; solid when alarm silenced capacity of 35 amp hours.An additional annunciator give on-site access to all cabinet enclosure(PN RBB)is required programming.You can also program Supervisory(Yellow): Flashes when a for batteries in excess of 18 amp hours. remotely using the 5660 Silent Knight supervisory condition exists; solid when Flexput circuits on 5820XL control can Software Suite,which is Windows®- supervisory silenced be individually programmed to function based software. System Troubles (Yellow): Flashes as notification circuits, auxiliary power when a trouble condition exists; solid outputs, or initiation circuits that Built-In Digital Communicator when trouble silenced support both 2-and 4-wire smoke 5820XL features a built-in UL listed detectors. digital communicator for remote System Silenced (Yellow): On when an The 5820XL system operates on non- g alarm,trouble or supervisory condition reporting of system activity and system twisted, unshielded cable when wired The communicator has has been silenced but not yet cleared programming. in compliance with standard wiring the ability to seize two telephone lines System Power(Green): Flashes for AC practices as called out in the National to report alarms and troubles to a failure; solid when power systems are Electric Code 760-51 specifications for monitoring facility.The communicator normal power-limited fire protective signalling supervises two phone lines and will cables. No special wiring is required. activate a trouble signal if a line failure System Application 5820XL provides 13 preset notification is sustained for more than 45 seconds. 5820XL has one built-in signalling line cadence patterns(including ANSI 3.41) Other communication features include: circuit(SLC)which supports multiple and four user programmable selections retry if communication fails,two phone devices dependent on protocol being for fire alarm notification. number capability, download phone used.Three additional loops can be Two programmable general purpose number capability and Touch-Tone or added usingthe 5815XL SLC Form C relay outputs are provided on rotary dialing.The communicator is expanders to increase overall capacity. 5820XL. compatible with SIA and Ademco Additionally, the IntelliKnight system Contact ID.The format is selectable by The 5820XL SLC loops support features a built-in walk test and auto- account number. multiple device types, including: programming. Its innovative, dead-front account number. • Addressable photoelectric smoke cabinet design allows for flush or detector surface mounting. System maintenance • Addressable ionization smoke is easy to perform. Ir■...a.- a.,ru..+ detector User Interface ° "'_'""' • Addressable heat sensor or -- _ The 5820XL built-in annunciator with ,, • Addressable duct smoke detector 80 character LCD display and large •r • Contact module easy-to-use tactile touchpad can be ` 'i •4 '." v used for system operation, r a rr t; • Relay output module programming and maintenance. It has ea rt • Addressable notification module five LEDs for alarm, supervisory, • Addressable beam detector(SK system trouble, system silenced and protocol only) system power.System operations • Addressable multi-criteria smoke include silencing alarms and troubles, Approvals detector(SK protocol only) resetting alarms and the display of NFPA 13, NFPA 15, NFPA 16, alarm troubles and memory. The NFPA 72: Central Station; Remote • Addressable multi modules(SK system's non-volatile event history Signalling; Local Protective Signalling protocol only) buffer stores 1000 events for viewing Systems;Auxiliary Protected Premises from the built-in or remote annunciator. Unit; &Water Delu a Releasing following advanced sensor9 capabilities are available with 5820XL: System operation can be initiated with Service.Suitable for automatic, a mechanical firefighter's key or a valid manual,waterflow, sprinkler • Automatic drift compensation 4-to 7-digit operator's code. supervisory(DACT non-coded) • Maintenance alert Programming signalling services. • Built-in sensor test to comply with The IntelliKnight system offers several Other Approvals: UL Listed; NFPA 72 calibration testing options to simplify and speed up CSFM 7170-0559: 135; requirements programming. The JumpStart®feature MEA 429-92-E Vol.VI; FM Approved minimizes programming INTELLIKNIGHT FIRE ALARM CONTROL PANEL IntelliKnight Model 5820XL Addressable Fire Alarm Control Panel IntelliKnight 5820XL `"°dows ley Addressable Fire Alarm System Management Software SK(System Sensor) Protocol Devices W ndows Based Up/Download Software Ir T -0. H Compalbk CS 4i-, Receiver t � I •ulomatp011 SaltwJfe T �i 411111111 0620%L SK-2/2U0 Connection UKorNirm IP Communicator Internet 5805XL Ina!poor 7kAN8,18888,8 a Prim C ROAR., .11 I II 5entrdae SA SB15XL 3 '.. SLC Pearce, PSi?J. LA 5860 5828 Remote K ¢ ar iendetdi F4rrlCdq M tAZZa otu[ .}I}li5 MmS'ycae) elib..!..0. y 6 Fbaput" k IR1 Circuits rn can be Inputs PLGPornender se _ naupUe._..,' n ■6Fl mts b clrtnls to be inputs i � rot output '.. 7.1 17) E 64 Eel:.9Uehr.Hvax..er00 C ya v 001* ® ¢ F S 1 ! inO rt 4 e l I • a ram- 8K-loh SKa111odty 6K-Iso BKtantrol.8 6K-0dtrd py806R 9(4Acdlnsste SK.2me6 �" . RGd'essath• / es9K1e Fw4lsobtar Altesate S9ras5e2 Soun Yr Mutrrtera Zane Iorixeon Menlo, Mode NarldWian Crtro'. 1888 Ors INWIScO 58= Woo" MOtlao nvc,ao WM% m448tCr Colic / )) I I 3arre[e Mnunceldr ti II .. l' • ii-# Li Q. I� —0 III SK-PndBO 611-118oHtor-1 SK-ttlaymott-Y BKaiear 6224R8 072481 8210LP 8K-PhOW-T za wants- 8818881818 8K-Reai-ROR Allay sa+arrIIII 5880 etldes.A18 MOtlu1e Pit Mentor See ear-HT 'a,, Lt. e._e 'tE - due MIOLWGdrld MT., el A1tr✓:aNe 1'n.t IALc< D6xGv rk.et ,nun .r. 111- 7*----i----1 j".. ' - 6q yv, 4 Paayln8r81...1...18, eK-0eas 81.Mbn.10 6KHJJ-0A 6K-Duct 6K-Mrdthon 8Kfletey-6 6K2one ge-tdey gm .Wtesseble 6KiVII-BA 857e85888= m:n[or Rena CO»dl 80183811; aato;Sm) YGametls Monihr wldessaia Duet Wale etcule oettere RAW Rwmr,e or MOO" Pot Sem Doe-tr. Mo0nne 1.001118 =__ n 58651 or 5865.3 I Use the 5880 to control up to a-_— sa slim) 15863 Relay Interface Modules I INTELLIKNIGHT FIRE ALARM CONTROL PANEL IntelliKnight Model 5820XL --- Addressable Fire Alarm Control Panel Specifications S-BUS Accessories _ Miscellaneous Accessories Electrical 5860/R Remote Fire Annunciator 5660 Silent Knight Software Suite Primary AC: Features the same 80 character backlit (SKSS) 120 VRMS at 50/60 Hz,2.5A or LCD display keypad and firefighter's User-friendly Windows software for 240 VRMS at 50/60 Hz, 1.4A keyswitch as the 5820XL. 5860 is gray remote programming of 5820XLs using Total Accessory Load: 6A @ 27.4 VDC, and 5860R is red. a PC. Upload and view panel account power-limited 5815XL Signal Line Circuit Expander information, event history, and detector Standby Current:215 mA The SLC expander is used to add more status. Alarm Current: 385 mA addressable devices to the IntelliKnight 5670 Silent Knight Software Suite system. 5820XL supports three (SKSS) Flexput Circuits: 5815XL's. Each 5815XL can support 99 Powerful end-user facility management Six programmable circuits which can be SK detectors and 99 SK modules or software allows viewing of detector programmed individually as: 127 SD devices. status and event history via modem or Notification circuits:3A @ 27.4 VDC 5895XL Intelligent Power Module direct connection. per circuit, power-limited Adds 6 amps of power,6 Flexput I/O Plex-1 Auxiliary power circuits: 3A @ 27.4VDC circuits and 2 Form C relay circuits to a Dead front cabinet door with clear per circuit, power-limited 5820XL system. window to limit access to the FACP. Initiation Circuits: 100 mA @ 27.4VDC 5496 Intelligent Power Module RBB per circuit, power limited A 6 amp notification power expander Remote battery box accessory cabinet. that provides four power-limited notifi- Use if backup batteries are too large to Physical cation appliance circuit outputs. fit into FACP cabinet. Dimensions: Flush Mount Dimensions: 5880 LED/IO Module 16"W x 10" H x 6" D 14.5"W x 24.75"H x 3.9"D Features 40 LED outputs, 8 normally (406 mm W x 254 mm H x 152 mm D) (36.8 W x 62.9 H x 9.8 D cm ) open dry contact inputs,and one piezo SD505-DTS-K output. Remote test switch. Used with Overall Dimensions: 5865-3 and 5865-4 SD505-DUCTR. Provides remote key 16.2"W x 26.4"H x 4.2"D Remote LED Annunciator operated test function and annunciation (40.6 W x 67 H x 11.8 D cm) Features 30 programmable LED(15 of detector alarm. red and 15 yellow)outputs, and a piezo SD and SK Devices Weight: 28 lbs. (12.8 kg) sounder.The 5865-4 adds a silence See the specification sheets listed Color: Red and reset switch to the package. below for a complete listing of the SD Battery Charging Capacity: 7.0-35 AH 5883 Relay Board and SK devices. Features 10 general purpose Form C 53624 SD Devices Data Sheet Battery Size: 18 AH max allowed in relays. Used with 5880 module. 53623 SK Devices Data Sheet control panel cabinet. Larger capacity 5824 Serial/Parallel Printer batteries can be housed in RBB Interface Module accessory cabinet. Provides one parallel and one RS-232 serial port for connecting a printer to Telephone Requirements: the 5820XL. Use to print a real-time log FCC Part 15 and Part 68 approved of system events, detector status Type of Jack: RJ31X(two required) reports, and event history. Interfaces with building control system. 4r SILENT This document is not intended to be used for installation purposes.We try to keep our Made in America product information up-to-date and accurate.We cannot cover all specific applications NI KNIGHT or anticipate all requirements.All specifications a e subject to change without notice. For more information,contact Silent Knight 12 Clintonville Road,Northford,CT 06472 PN 350210 Rev H2 by Honeywell Phone:(203)484-7161,Fax:(203)484-7118.www.silentknight.com. ©2012 Honeywell International Inc. IntelliKnight&JumpStart are Registered Trademarks of Silent Knight Flexput is a Trademark of Silent Knight Honeywell DSILENT' KNIGHT 5860 Remote Annunciator The 5860 remote annunciator,can be used to operate and program Honeywell Silent Knight fire alarm control panels(FACPs)from anywhere within the system. The 5860 features include an 80-character backlit LCD providing easy-to ' ' understand system messages.The annunciator is ergonomically designed with over-sized buttons for the most frequently used features,like Reset , -$ 4 and Silence. € , 6 9 V In addition to status messages displayed on the LCD,there are five LEDs for alarm,supervisory,trouble,silence,and AC power status, The 5860 annunciator is available in gray to match virtually any decor and 5860/5860R red for applications where the annunciator must stand out.The annunciator enclosure can be surface or flush mounted.A trim ring kit is available for surface mounting. COMPATIBILITY The 5860 is compatible with the following Honeywell Silent Knight FACPs: 6820:Addressable fire alarm control panel with up to 1,110 addressable points 6820EVS:Addressable fire alarm control panel with an emergency communication systems and up to 1,110 addressable points 6808:Addressable fire alarm control panel with up to 198 addressable points 6700:Addressable fire alarm control panel with up to 100 addressable points 582OXL:Addressable fire alarm control panel 582OXL-EVS:Addressable fire alarm control panel with an emergency communication systems 58O8:Addressable fire alarm control panel 5700:Addressable fire alarm control panel FEATURES & BENEFITS • 80-character backlit • Support for • Five Status LEDs • Accommodates wiring • Accepts user codes or LCD display(4 lines simultaneous use of • Available in red or light lengths up to 6000 ft. fire fighter's key with 20 characters per multiple 5860s gray color from the control panel tine) Easily• view current g y for added design and • Larger keypad buttons makes it easier to • Tactile/audible status by alarms, install flexibility maneuver for system feedback when a key is supervisories,or reset and silencing pressed on the troubles annunciator • Uses the RS-485 SBUS to interface with the panel 5860 Technical Specifications For a complete listing of all compliance approvals and certifications,please visit www.silentknight.com. Microsoft,Windows,and the Windows Logo are registered trademarks ortrademarks of Microsoft Corporation. Wire Runs Up to 6000 Feet From FACP Silent Knight°and .,. Honeywell°are registered '® ^ ,�,a, trademarks of Honeywell SBUS 1A T� l � ' m Thisrna documelntrc.is not intended to be used for 5860 5860 5860 installation purposes.We try to keep our product •Up to Eight 5860s Per 5700 or 6700 System information up-to •Up to 12 5860s Per 5808,6808,5820XL,or 5820XL-EVS System date and accurate.We •Up to 16 5860s per 6820 or 6820EVS System cannot cover all specific Compatible Silent Knight FACP applications or anticipate all requirements.All specifications are subject to change without notice. For Technical Support, call 800-446-6444. 5860 Features PHYSICAL ORDERING INFORMATION Dimensions:9.1'W x 7.4'H x 1.5"D(23.1W x 18.8H x 5860:Remote Annunciator,four line(4x20)LCD 3.8D cm) annunciator with 20 characters per line.Gray Shipping Weight:2.8 lbs(1.3 kg) 5860R:Remote Annunciator,four line(4x20)LCD Color:5860R:Red;5860:Gray annunciator with 20 characters per line.Red ENVIRONMENTAL ACCESSORIES Operating Temperature:32°F to 120°F(0°C to 5860TR:Red Trim Ring for surface mounting 49°C) 5860TG:Gray Trim Ring for surface mounting H umidity:10%-93%non-condensing) AGENCY LISTINGS AND APPROVALS ELECTRICAL UL listed Operating Voltage:24VDC CSFM approved Standby Current:20mA Meets NFPA 72 requirements Alarm Current:25mA FM approved MEA approved For more information Learn more about Honeywell Silent Knight and other products by visiting www.silentknight.com Honeyw Clintonllville Sillet Kdight Honeywell 12 Clintonville Road Northford,CT 06472 Doc 350224 I Rev J 112/17 SILENT 800-328-0103 ,o 2017 Honeywell International Inc. ®KNIGHT DUPAC ELI SLA Batteries General Purpose ULTRABackup and deep cycle applications Duracell® Ultra SLA technology offers high-density power that out- performs traditional lead acid batteries. The Absorbed Glass Mat (AGM) construction is designed for efficient gas recombination and allows for maintenance-free operation. Duracell® Ultra SLA batteries maintain their high capacity with a design that is resistant to damage caused by deep discharge. Every Duracell® Ultra SLA ' battery is inspected to ensure I ri ; I the highest standards in materials and fabrication. 450-150 01 � AGM ilk Cycles at 100% Discharge LW MO oaau3-eF rucoe E]t EO NONSPIIIP�Pit[P� LGMr('�� D CC 1nun�unn�mm SPILL U LTR � � s PROOF %% �. GUARANTEE Features: • Duracell®Ultra SLA GEL batteries contain a proprietary grid alloy formula combined with advanced plate curing techniques to provide maximum performance. • Duracell® Ultra batteries contain a unique electrolyte formula with a special sub-colloid additive for higher reliability and longer life. • Will achieve more life cycles than standard AGM and Deep Cycle batteries. -----_ • The unique construction and sealing techniques of these batteries DURACELL are guaranteed to give you leak-proof operation. .:. • Heavy-duty lead calcium tin alloy grids provide an extra margin of performance i and service life in cyclic applications, even after repeated over-discharges. • Quality Assurance Engineers monitor and control the entire production process. • Recycling of used SLA batteries available. �O CASE p❑ • Delivery available. f'1�11-1 Quantities u�H, AVAILABLE ❑❑❑❑ Sealed • 1 a� Lead 41./ YEAR A • c i a Maintenance Free Spill Proof 1 Year Stringent Quality Design Warranty Control batteriesplus.com 1-800-677-8278 PROJECT DU RAC EL L SLA Batteries CATALOGNME- ULTRA FIXTURE TYPE NOTES General Purpose Battery Volts CapacityAh(20Hrs) Dimensions(LxWxH Inches) Terminal Type Group Size Weight(Lbs.) DURA12-0.8WL 12V O 8 3.78 0.98 i 2.4 WL 0.77 DURA12-1.3F 12V 1.3 3.82 1.69 2.28 F1,T1 137 DURA12-2.3F 12V 23 6.97 1.38 2.64 F1,T1 - 2.04 DURA12-2.9F 12V 2.9 3.11 2.2 3.9 F1,T1 - 2.36 DURA12-3.3F 12V 3.3 5.28 2.64 2.63 F1,T1 - 3.18 DURA12.3.3F2 12V 3.3 - - - - - RAYA12-4F 12V 4 3.54 2.76 4.21 F1,T1 • - DURA12-5F 12V 5 3.54 2.76 4.21 F1,T1 - - DURA12-5F2 12V 5 _ 3.56 2.77 3.94 F2,T2 - DURA12-5.1A 12V 5.1 5.51 1.89 4.21 F1,T1 . 4.6 DURA12-5.5F 12V 5.5 3.54 2.76 3.98 - - - RAYA12-7F 12V 7 5.95 2.56 3.94 F1,T1 - - DURA12-7F 12V 7 5.94 2.56 3.94 F1,T1 - - DURA12-7F2 12V 7 5.94 2.56 3.7 F2,T2 - - DURA12-8F 12V 8 5.94 2.56 3.94 F1,11 - - DURA12-8F2 12V 8 5.94 2.56 3.94 F2,T2 - - DURA12-9NB 12V 9 5.95 2.56 3.9 NB,1 - - DURA12-9F2 12V 9 5.95 2.56 3.94 F2,T2 - - DURA12-10F2 12V 10 5.95 2.54 4.38 F2,T2 - 7.5 DURA12-11N8 12V 11 5.28 3.15 6.5 - _ 10.1 -> DURA12-12F2 12V 12 5.94 3.9 3.98 F2,T2 - - DURA12.12F 12V 12 5.94 3.86 3.86 F1,T1 - - DURA12-14F2 12V 14 5.94 3.86 3.98 F2,T2 - 8.91 DURA12-18F2 12V -_, 18 7.13 3.03 6.57 F2,T2 - - DURA12-1BNB 12V 18 7.13 3.03 6.57 NB,J - 12.43 DURA12-26NB 12V 26 6.5 6.93 4.92 NB,1 - 20.7 DURA12.35C 12V 35 7.72 5.16 6.5 C 27.3 DURA12-44C/FR 12V 46 7.8 6.54 6.85 C - 38 DURA12-55CJFR 12V 55 9.02 5.43 8.35 - . 42.1 DURA12-80C/FR 12V 80 10.24 6.65 8.46 C - - DURA12-100C/FR 12V 100 12.09 6.65 8.46 C - 74.6 DURA12.140C/FR 12V 140 13.43 6.81 11.3 C - 108 DURA4-4.5F2 4V 4.5 1.85 1.85 3.98 F2,72 - 1.4 ___ DURA6-1.3F 6V 1.3 3.82 0.94 2.28 F1,T1 - 0.715 DURA6-2ST 6V 2 1.69 1.45 2.99 ST - 0.75 DURA6-2.9F 6V 2.9 2.6 1.46 3.82 F1,T1 - 1.26 DURA6-3.3F 6V 3.3 5.28 1.34 2.64 F1,T1 - 1.65 RAYA6-4F 6V 4 2.76 1.85 4.13 F1,T1 - DURA6-5SP 6V 5 2.6 2.6 4.53 SP - 2.09 DURA6-5F 6V 5 2.76 1.85 4.21 F1,T1 - - DURA6-7.2F 6V 7.2 5.94 1.34 3.68 F1,T1 - 2.43 DURA6-8.2F 6V 8.2 3.9 2.24 4.53 F1,T1, - 3.8 DURA6-10F 6V 10 5.94 1.97 3.98 F1,T1 - 4.851 DJRA6-12F 6V 12 5.94 1.97 3.98 F1,T1 - - DURA6-12F2 6V 12 5.94 1.97 3.98 F2,72 - 4.602 RAYA6-14T2__ 6V 14 4.25 2.8 5.51 H - 6.24 DURA6-14A 6V 14 4.25 2.8 5.51 Ft(-)F2(+),T1(-)T2(+),FP - 6.16 DURA6-42F2 6V 42 6.25 3.37 6.37 F2,T2 - 16.64 DURA6-42NB 6V 42 6.34 3.43 6.42 NB,J - 16.62 DURA6-200C 6V 200 12.05 6.65 8.63 C - - DURA8-3.2F 8V 3.2 5.28 1.44 2.48 F1,T1 - 1.65 Visit batteriesplus.com for warranty information Batteries-P Bulbs. 0 2017 DURACELL,Bethel,CT 06B01.Duracell is a registered trademark of Duracell U.5.Operations.Inc.used under license.All rights reserved.resed. BATTERY CALCULATIONS Gabell'ro]ectValues: itSILENT Project Name: CFT Elementary TTSD Standby Hours: 24 KNIGHT Project ID:I109395 I Alarm Mins:1 5 Prepared By:IE Chiong Derating Factor: 1.2 5820XL Calculations Date:I8/11/2020 Voltage Drop Warning Version 02.26.09 Threshold%: 10 Panel ID: I5820)L -1 Model: 5820XL Add.Fire Alarm Control Panel Max NAC Current: 3.0 Amps Location: 1st Fir Main Office Work Rm Volts: 24 VDC Max Panel Current: 6.0 Amps Ckt.# Circuit Name Qty Current Draw Wire AWG Ohms Per Length(R) Actual Volts @ %Drop Standby Alarm &Type 1000 Ft. One-Way Ohms EOL 5820XL 5820XL CTRL Panel 1 0.215 0.385 SD500-AIM Addr.Input Mod 3 0.002 0.002 SD500-MIM Mini-Input Module 0.000 0.000 SD500-ARM Addr.Relay Module 5 0.003 0.003 SD500-PS Addr.Pull Station 18 0.010 0.010 SD505-AIS Addr.Ion Smoke Det 0.000 0.000 SD505-AHS Addr. Heat Detector 9 0.005 0.005 SD505-APS Addr.Photo Smoke Det 157 0.086 0.086 SD505-DUCTR Addr.Duda/Relay 0.000 0.000' SD505-DUCT Addr.Duct 0.000 0.000 SD500-ANM Addr.Notification Module 0.000 0.000' SD500-LED Addr.LED Module 0.000 0.000' SD500-SDM Addr.Smoke Det Mod. 0.000 0.000' SD505-6RB Addr.Det.Relay Base 0.000 0.000 SD505.6SB Addr.DeL Sounder Base 0.000 0.000' SD50561B Addr.Det.Isolator Base 0.000 0.000 SD500-LIM Line Isolation Module 0.000 0.000 5815XL SLC Loop Expander 0.000 0.000 5860 LCD Remote Annunc 1 0.020 0.025 5824 Serial/Parallel Module 0.000 0.000 5496 Power Expander 0.000 0.000 5895XL Power Expander 0.000 0.000 PSSATK Amrnciator 0.000 0.000 5865-3 LED Annunciator(3G) 0.000 0.000 5880 LED Drher Module 0.000 0.000 5883 Relay Module 0.000 0.000 PGM-1/O#1 MSC Trwer(Expander f#1.S) cfa 0.000 1.500 *14solid • 2.52 0.00 20.40 0.00% PGM-VO#2 Notification Appl Circuit cfa 0.000 0.000 I.12 Solid • 1.59 0.00 20.40 0.00% PGM-VO#3 Notification Appl Circuit cfg. 0.000 0.000 •12 Solid • 1.59 0.00 20.40 0.00% PGM-VO#4 Notification Appl Circuit cfa 0.000 0.000 ►12 Solid • 1.59 0.00 20.40 0.00% PGM-VO#5 Notification Appl Circuit cra 0.000 0.000 •12 Solid • 1.59 0.00 20.40 0.00% PGM-VO#6 Notification Appl Circuit cra 0.000 0.000 I.12 Solid + I 1.59 0.00 20.40 0.00% Total Standby Current(Amps) 0.341 2.016 Total Alarm Current(Amps) Standby Time In Hours 24 0.083 Alarm Time In Minutes/60 (5 Mins) Total Standby AH Required 8.174 0.168 Total Alarm AH Required Total Combined AH Required 8.34 Command Shortcuts Multiply By The Derating Factor 1.20 Minimum Battery Am ours Required 10.01 CoPrint Page PH q Configure Circuits MATRIX OF OPERATIONS SYSTEM OUTPUTS O F- a w z Z D a Z CY LU a Z J __IQ Q Cy < CY wK Q I V- K J Q d O J a o O J V ¢ O . U_ J w a U w' U— '� Q LL 2 J O ,X - Z < w V EY a_ _ I h K w V CY w ce Z —LL ( 4 <a a "' Q ¢ Om f v - 0 } Z Z J 2 w Q F Q Q K K ayI- ZFOOO N_ N J Q O O Q D > > D O O Z O >_ H J -' w Q Q I-' ur 4 O w w w w v, Q Q - w U V < FACP AC POWER LOSS • • • FACP BATTERY POWER LOSS • • • REMOTE NAC PANEL AC POWER LOSS • • • REMOTE NAC PANEL BATTERY POWER LOSS • • • FIRE ALARM SYSTEM OPEN CIRCUIT • • • FIRE ALARM SYSTEM GROUND FAULT • • • RR E ALARM SYSTEM TROUBLE • • • cn z ELEVATOR MACHINE ROOM SMOKE DETECTOR ELEVATOR MACHINE ROOM HEAT DETECTOR • • • • • I- ELEVATOR HOISTWAY HEAT DETECTOR • • • • • ol h ELEVATOR HOISTW AY SMOKE DETECTOR • • • • • • ELEVATOR PRIMARY LEVEL SMOKE DETECTOR • • • • • ELEVATOR NON-PRIMARY LEVEL SMOKE DETECTOR • • • • • , WET SYSTEM SPRINKLER WATER FLOW SWITCH • • • • WET SYSTEM SPRINKLER TAMPER SWITCH • • • GENERAL HEAT DETECTOR • • • • GENERAL SMOKE DETECTOR • • • • MANUAL PULL STATION • • • •