Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Report
/III/ N• - •S. ; • M-SERIES SUBMITTAL DATA: MSZ-D36NA & MUZ-D36NA MITSUBISHI 36,000 BTUIH WALL-MOUNTED HEAT PUMP SYSTEM M ELECTRIC Job Name: i w COPY System Reference: Date: Indoor Unit: Outdoor Unit: Wireless Remote Controller MSZ-D36NA MUZ-D36NA .44 arrr • �gl��\��' '�' • ,< a II GENERAL FEATURES • Slim wall-mounted indoor units provide zone comfort control. • The outdoor unit powers the indoor unit,and should a power outage occur,the system is automatically restarted when power returns. • INVERTER-driven compressor and LEV provide high efficiency and comfort while using only the energy needed to maintain maximum performance • Multiple fan speed options:Low,Medium, High,Powerful,Auto • Multiple control options available: -Hand-held Remote Controller(provided with unit) -kumo cloud®smart device app for remote access -Third-party interface options -Wired or wireless controllers • Hot-Start Technology:no cold air rush at equipment startup or when restarting after Defrost Cycle • Powerful Operation:quickly cools or heats the room by automatically adjusting fan speed and set temperature for 15 minutes • Smart Set:recalls a preferred preset temperature setting at the touch of a button • Wide Vane mode provides 150°of airflow Specifications are subject to change without notice. ©2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. SPECIFICATIONS: MSZ-D36NA & MUZ-D36NA Maximum Capacity Btu/h 33,200 Rated Capacity Btu/h 33,200 Minimum Capacity Btu/h 9,800 Maximum Power Input W 4,360 Cooling — Rated Power Input W 4,360 Moisture Removal Pints/h 11.3 Sensible Heat Factor 0.62 Power Factor % 99/99 Maximum Capacity Btu/h 36,000 Rated Capacity Btu/h 35,200 Minimum Capacity Btu/h 8,700 Heating at 47°F2 Maximum Power Input W 4,100 Rated Power Input W 3,840 Power Factor % 99/99 Maximum Capacity Btu/h 22,800 Rated Capacity Btu/h 21,800 Heating at 17°F3 Maximum Power Input W 3,000 Rated Power Input W 3,000 SEER 14.5 EER1 7.6 Efficiency HSPF(IV) 8.2 COP at 47°F2 2.69 .____-___-_------- COP at 17°F in Maximum Capacity3 2.23 Voltage,Phase,Frequency 208/230V, 1 phase,60Hz Guaranteed Voltage Range V AC 187-253 Voltage:Indoor-Outdoor,S1-S2 V AC 208/230 Electrical Voltage:Indoor-Outdoor,S2-S3 V DC 24 Voltage:Indoor-Remote Controller Wireless Type Recommended Fuse/Breaker Size A 25 Recommended Wire Size(Indoor-Outdoor) AWG 14 MCA A 1 MOCP A 15 Blower Motor Full Load Amperage A 0.76 Blower Motor Output W 56 Airflow Rate at Cooling,Dry CFM 887-848-639-389 Indoor Unit Airflow Rate at Cooling,Wet CFM 798-763-576-350 Airflow Rate at Heating,Dry CFM 887-848-639-445 Sound Pressure Level(Cooling) dB(A) 51-49-42-32 Sound Pressure Level(Heating) dB(A) 50-49-42-34 Drain Pipe Size In.(mm) 5/8(15.88) Heat Exchanger Type Plate fin coil Specifications are subject to change without notice. ®2019 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. SPECIFICATIONS: MSZ-D36NA & MUZ-D36NA External Finish Color Munsell 3Y 7.8/1.1 W: In.(mm) 46-1/16[1,170] Unit Dimensions D: In.(mm) 11-5/8(295) H:In.(mm) 14-3/8(365) W:In.(mm) 51 (1,295) Package Dimensions D:In.(mm) 14-1/4(362) H:in.(mm) 18-1/2(470) Unit Weight Lbs.(kg) 40(18) Package Weight Lbs.(kg) 53(24) Indoor Unit Operating Cooling Intake Air Temp(Maximum/Minimum)* °F 90 DB,73 WB/67 DB,57 WB Temperature Range Heating Intake Air Temp(Maximum/Minimum) °F 80 DB/70 DB MCA A 21 MOCP A 25 Fan Motor Full Load Amperage A 0.93 ------- --- --- Fan Motor Output W 77 Airflow Rate CFM 1,941 /1,941 Refrigerant Control LEV Defrost Method Reverse cycle Heat Exchanger Type Plate fin coil Sound Pressure Level,Cooling1 dB(A) 56 Sound Pressure Level,Heating2 dB(A) 56 Compressor Type DC INVERTER-driven Compressor Model TNB220FMCHT Outdoor Unit Compressor Rated Load Amps A 16 Compressor Locked Rotor Amps A 20 Compressor Oil Type II Charge oz. NE022//29.4 External Finish Color Munsell 3Y 7.8/1/1 Base Pan Heater N/A W:In. (mm) 33-1/16(840) Unit Dimensions D: In.(mm) 13(330) H: In.(mm) 33-7/16(850) W: In. (mm) 39(990) Package Dimensions D: In.(mm) 18 1/2(470) H:In.(mm) 39 3/4(1,010) Unit Weight Lbs.(kg) 141 (64) Package Weight Lbs.(kg) 168(76) Cooling Air Temp(Maximum i Minimum)* °F 115/14 Outdoor Unit Operating Cooling Thermal Lock-out/Re-start Temperatures** °F -4/0 Temperature Range Heating Air Temp(Maximum/Minimum) °F 14 to 75 Heating Thermal Lock-out/Re-start Temperatures** j °F N/A Refrigerant Type R410A Specifications are subject to change without notice. ©2019 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. SPECIFICATIONS: MSZ-D36NA & MUZ-D36NA Charge I Lbs,oz 4, 10 Gas Pipe Size O.D.(Flared) In.(mm) 5/8(15.88) Liquid Pipe Size O.D.(Flared) In.(mm) 3/8(9.52) Piping Maximum Piping Length Ft.(m) 100(30) Maximum Height Difference Ft.(m) 50(15) Maximum Number of Bends 10 Notes AHRI Rated Conditions 1Cooling(Indoor//Outdoor) °F 80 DB,67 WB//95 DB,75 WB (Rated data is 2Heating at 47°F(Indoor//Outdoor) °F 70 DB,60 WB//47 DB,43 WB determined at a fixed compressor speed) 3Heating at 17°F(Indoor//Outdoor) °F 70 DB,60 WB//17 DB, 15 WB ;Applications should be restricted to comfort cooling only;equipment cooling applications are not recommended for low ambient temperature conditions. **System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures. Specifications are subject to change without notice. ©2019 Mitsubishi Electric Irene HVAC US LLC.All rights reserved. ACCESSORIES: MSZ-D36NA Anti-allergy Enzyme Filter ❑MAC-1415FT-E Backlit,Wall-mounted,Wireless Controller c MHK1 Portable Central Controller c MCCH1 Wired MA Controller) o PAR-33MAA Simple MA Controller1 o PAC-YT53CRAU Touch MA Controllers ❑PAR-CT01MAU-SB Wireless Temperature and Humidity Sensor o PAC-USWHS003-TH-1 Outside Air Sensor for MHK1 c MOS1 System Control Interface2 o MAC-3331F-E ----------- Wireless Interface ❑PAC-USWHS002-WF-1 Thermostat Interface ❑PAC-US444CN-1 kumo station TM ❑PAC-WHS01 HC-E USNAP Interface ❑PAC-WHS01 UP-E IT Extender ❑PAC-WHS011E-E BACnete and MODBUS®Interface ❑PAC-UKPRC001-CN-1 Lockdown Bracket for Hand-held Remote Controllers a RCMKP1 CB Blue Diamond Sensor Extension Cable-15 Ft. ❑C13-103 Blue Diamond Alarm Extension Cable-6.5 Ft. ❑C13-192 Blue Diamond MultiTank—collection tank for use with multiple pumps ❑C21-014 Blue Diamond Rubber Foot Pads ❑F10-010 Mini Condensate Pump-230 volt application c S130-230 MegaBlue Advanced Blue Diamond Condensate Pump w/Reservoir&Sensor c X87-835-110 to 250V MaxiBlue Advanced Blue Diamond Mini Condensate Pump wl Reservoir&Sensor(110V)up to 48,000 Btu/h ❑X87-711 -110V [recommended] Advanced Blue Diamond Mini Condensate Pump w/Reservoir&Sensor(208/230V)[recommended] I o X87-721 -208/230V MicroBlue Blue Diamond Mini Condensate Pump(110/208/230V)up to 18,000 Btu/h o X85-003 Fascia Kit for MicroBlue Pump—mounts the MicroBlue and sensor directly beneath the indoor unit o T18-016 Drain Pan Level Sensor ❑DPLS2 (30A/600V/UL)[fits 2"X 4"utility box]-Black ❑TAZ-MS303 (30A/600V/UL)[fits 2"X 4"utility box]-White ❑TAZ-MS303W s Requires MAC-333IF-E 2 Allows indoor units to connect to an MA Controller Specifications are subject to change without notice. ©2019 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. ACCESSORIES: MUZ-D36NA Drain Socket ❑MAC-811 DS Outdoor Unit 3-1/4 inch Mounting Base(Pair)-Plastic o DSD-400P Condensing Unit Mounting Pad 16"x 36"x 3" ❑ULTRILITE1 Outdoor Unit Stand-12"High ❑QSMS1201 M Outdoor Unit Stand-18"High o QSMS1801 M Outdoor Unit Stand-24"High o QSMS2401M ---------- Heavy Duty Wall Mounting Bracket—Coated Steel o QSWB2000M-1 Heavy Duty Wall Mounting Bracket-316 Series Stainless Steel o QSWBSS 10'x 3/8"x 10'x 5/8"Lineset(Twin-Tube Insulation) ❑MPLS385812T-10 15'x 3/8"x 15'x 5/8"Lineset(Twin-Tube Insulation) ❑MPLS385812T-15 30'x 3/8"x 30'x 5/8"Lineset(Twin-Tube Insulation) ❑MPLS385812T-30 50'x 3/8"x 50'x 5/8"Lineset(Twin-Tube Insulation) ❑MPLS385812T-50 65'x 3/8"x 65'x 5/8"Lineset(Twin-Tube Insulation) ❑MPLS385812T-65 100'x 3/8"x 100'x 5/8"Lineset(Twin-Tube Insulation) o MPLS385812T-100 Specifications are subject to change without notice. ©2019 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. DIMENSIONS: MSZ-D36NA Unit: inch al 2-11/16. Indoor unit 4-11/16 col I ea N 17.7.1 JI . WWW _ _ 1 2-3/t6'-1 F 20-718 17-11/16 k5-3/8 - 11-5/8 1/4\ Wall hole 03 ,/ kl 1 46 1/-6 Air in F--- ___ ...... -__ _._-_._.-_ li ` Installation plate frpjam V r ..--.. Ii1111111I= t \ -_-__1 `- r 9-1/2 � 2 1516 33-11/-6 •. I ! Drain hose N `�J a 2-5/8 �j 1< Air out k 5-7/8 kI 2-5/16 3l4 I Piping Insulation Liquid line j03I819.11116 01-1/40.D ro _L9 (Flared connectIon e318) e9116 ID Gas line 0518 16-7/8 01-15116 0.D Wireless remote controller (Joint connectione5/8) 01-114l.D Joint 0518 e1-15116 0.D (Flared connection 0518) 01.114 I.D Drain hose Insulation et-1/8 Connected part 0518 0.D Required Space (Indoor Unit) _. kI 4-11116amore 8-11/16e more __H I ___lit E gi sl l ea sl I;:-. a1 1 I 1 , 43116 or more 9316ormae > a I In case of left,left back, or left under piping(using spacer)5-118 or more Specifications are subject to change without notice. ©2019 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. DIMENSIONS: MUZ-D36NA Unit: inch REQUIRED SPACE Open as a rule 20 in.or more if the front and both sides 20-9/32 are open Ouln 3 notes 11-25/32 M 1-9/16 lm 1-5/I61 Aii in lit �•]t 1 a 4 in.or more/ vl — " or, 8 in.or more if Aips _ - more j there are obstacles 1, lk \ 0 to both sides IMMONIMEN A at 4-3/1013/15 slot ►Iy ro- Or/77pe 9-l✓16 3-3/16 Open as a rule 33-1/16 20 in.or more if the back, both sides and top are open .r . i 1 r irei tr U Gas :5/9 - .0V --• .---,.-7.—s-1.-. r ArtMITSUBISHI ELECTRIC COOLING & HEATING 1340 Satellite Boulevard,Suwanee,GA 30024 Toll Free:800-433-4822 www.mehvac.com AlIllricEPTIFIED- FORM#MSZ-D36NA/MUZ-D36NA-201901 ""-- Intertek Specifications are subject to change without notice. ©2019 Mitsubishi Electric Trane HVAC US LLC.All rights reserved.