Plans (33) M EC2019-00536 / \ / \ / \ / \ MECHANICAL SYMBOLS AND ABBREVIATIONS MECHANICAL SYMBOLS AND ABBREVIATIONS MECHANICAL ABBREVIATIONS DRAWING INDEX RECEIVED ___ SYMBOL ABBREV. DESCRIPTION SYMBOL ABBREV. DESCRIPTION ABBREV. DESCRIPTION DWG. DESCRIPTION JUL 2 3 2019 Wr r� 'I�'.' D .;v �j j�j j j�j �j�j�jfMP0.0 MECHANICAL TITLE SHEET C TY `'F(D) PIPING / EQUIPMENT TO BE REMOVED FC FORWARD CURVED (FAN) MP0.1 MECHANICAL SPECIFICATIONS BUILDIOC, OIVL 3N (N) PIPING / EQUIPMENT TO BE PROVIDED / ��s +- 1=4 0-op0 SA SUPPLY DUCT TURN UP FCO FLOOR CLEAN OUT (E) PIPING / EQUIPMENT TO REMAIN FF FINISHED FLOOR M1 .0 HVAC SCHEDULES M2.0 FLOOR PLAN - HVAC (F) FUTURE PIPING / EQUIPMENT i D4.- ;,%(j 1 op I-,x.) SA SUPPLY DUCT TURN DOWN FPM FEET PER MINUTE M8.0 HVAC DETAILS WOODBLOCK ARCHITECTURE, INC. 107 SE WASHINGTON STREET,SUITE 250 W SANITARY DRAIN (ABOVE GRADE DRAIN) FPS FEET PER SECOND PORTLAND.OR 197214 I P503.889.0604 P1 .0 PLUMBING SCHEDULES W SANITARY DRAIN (BELOW GRADE DRAIN) 00 RA RETURN AIR FA FREE AREA P2.0 FLOOR PLAN - PLUMBING o o 0 o W SANITARY DRAIN (PUMPED) FT FOOT OR FEETy,`OD W(8, SD SD STORM DRAIN (ABOVE GRADE DRAIN) ® EXH EXHAUST GA GAUGE �' 77.9 ¢ — — — SD — — SD STORM DRAIN (BELOW GRADE DRAIN) GAL GALLONS) -I V fJ- V - — — — - V — — — — — V VENT O C4 OSA OUTSIDE AIR GALV GALVANIZED OREGON GPH GALLONS PER HOUR �� v s,�o,� ACID ACID ACID DRAIN Fy0 OO FSD FIRE SMOKE DAMPER GPM GALLONS PER MINUTE Aly C. P AV AV ACID VENT CW COLD WATER I EXPIRES 12-31-17 I 0 FD FIRE DAMPER HD HEAD / HUB DRAIN MVD MANUAL VOLUME DAMPER HG MERCURY •• • HW HOT WATER � MOTORIZED DAMPER HOA HAND OFF AUTO ••• ••• HWR HOT WATER RETURN Imo._ BACKDRAFT DAMPER HP HEAT PUMP / HORSEPOWER G G NATURAL GAS O TEMPERATURE SENSOR HR HOUR AIR A COMPRESSED AIR 0 WALL MOUNTED THERMOSTAT HTG HEATING P P PROPANE QT CEILING MOUNTED THERMOSTAT HZ HERTZ (FREQUENCY) 02 02 OXYGEN IE INVERT ELEVATION F F FIRE PROTECTION +- ACOUSTICAL LINER IN INCH(ES) S S STEAM (15 PSIG) KW KILOWATT C C CONDENSATE RETURN FLEXIBLE DUCT HWH KILOWATT-HOUR PC PC CONDENSATE RETURN (PUMPED) LAT LEAVING AIR TEMPERATURE HWS HWS HEATING WATER SUPPLY (LOW TEMP) J 1L1+- 1110 EQUIPMENT CONNECTION LBS POUNDS HWR HWR HEATING WATER RETURN LVG LEAVING RL RL REFRIGERANT LIQUID LINE 101111°. DUCT PRESSURE CLASS SYMBOL LWT LEAVING WATER TEMPERATURE RS RS REFRIGERANT SUCTION LINE t 1M 1r MAX MAXIMUM CHS CHS CHILLED WATER SUPPLY � MBH BTU PER HOUR (THOUSANDS) V\ ISI SUPPLY DIFFUSER/GRILLE MECH MECHANICAL CHR CHR CHILLED WATER RETURN CWS CWS CONDENSING WATER SUPPLY —7 MIN MINIMUM / # RETURN DIFFUSER/GRILLE N/A NOT APPLICABLE CWR CWR CONDENSING WATER RETURN NC NOISE CRITERIA / NORMALLY CLOSED D D DRAIN (INDIRECT) 7 EXHAUST DIFFUSER/GRILLE NIC NOT IN CONTRACT ITA TRIPLE DUTY VALVE NIM NOT IN MECHANICAL BALL VALVE I I LINEAR SLOT DIFFUSER NO NORMALLY OPEN / NUMBER — 'F' BUTTERFLY VALVE SIDEWALL DIFFUSER/GRILLE NTS NOT TO SCALE —NI— CHECK, SWING VALVE TOP DETAIL/SECTION NUMBER OBD OPPOSED BLADE DAMPER ` / CHECK, SPRING VALVE BOT DETAIL/SECTION SYMBOL OD OUTSIDE DIAMETER / OVERFLOW DRAIN -14E)- BALANCING VALVE ~~ DRAWING WHERE DETAIL/SECTION APPEARS OFCI OWNER FURNISHED CONTRACTOR INSTALLED NOTE: FLOW CONTROL VALVE $ POINT OF CONNECTION TO (E) OSA OUTSIDE AIR NOT ALL SYMBOLS AND ABBREVIATIONS MAY BE USED. .moo TOP NEW EQUIPMENT IDENTIFICATION PD PRESSURE DROP/ DIFFERENCE -•1 FLOAT VALVE :7,1 GATE VALVE BOT NEW EQUIPMENT MARK PH PHASE GATE ANGLE VALVE NEW EQUIPMENT NUMBER iPPM PARTS PER MILLION EXISTING EQUIPMENT IDENTIFICATION GLOBE ANGLE VALVE X-1 EXISTING EQUIPMENT MARK PRV PRESSURE REDUCING VALVE �� PSI POUNDS PER SQUARE INCH ----41.---- PLUG VALVE EXISTING EQUIPMENT NUMBER PSIA PSI, ABSOLUTE SAFETY RELIEF VALVE —_— NECK SIZE (IN) PSIG PSI, GAUGE GLOBE VALVE -..--------------------„8_10._--= DIFFUSER/GRILLE MARK ►� PRESSURE REDUCING VALVE 1Q0 , CFM P&T PRESSURE & TEMPERATURE RELIEF VALVE (R) RELOCATE(D) HomeStreet Bank Pi SOLENOID VALVER RADIUS Tigard Branch gi 2-WAY CONTROL VALVE > AD ACCESS DOORRA RETURN (AIR) 16230 SW Pacific Hwy Tigard,OR 97224 3-WAY CONTROL VALVE AF AIR FOIL (FAN) RD ROOF DRAIN �� HOSE BIB AFF ABOVE FINISHED FLOOR RECIRC RECIRCULAT - (E, ING, OR) ® M ED FLOOR DRAIN APD AIR PRESSURE DROP REQ REQUIRED E il ® FS FLOOR SINK AVG AVERAGE RH RELATIVE HUMIDITY BHP BRAKE HORSEPOWER RPM REVOLUTIONS PER MINUTE ---•+ WCO WALL CLEAN OUT ® ® CB CATCH BASIN BI BACKWARD INCLINED (FAN) SA SUPPLY (AIR) WALL HYDRANT / HOSE BIB BLDG BUILDING SAT SATURATION Y FDC FIRE DEPARTMENT CONNECTION BOD BOTTOM OF DUCT SCFM CFM, STANDARD CONDITIONS 0FIRE HYDRANT BOP BOTTOM OF PIPE SD SMOKE DAMPER / STORM DRAIN 4 WHA BTU BRITISH THERMAL UNIT SEC SECOND WATER HAMMER ARRESTOR BTUH BTU PER HOURSF SQUARE FEET Project#17-016 BFP BACKLFLOW PREVENTER, DOUBLE CHECK CFM CUBIC FEET PER MINUTE SM SHEET METAL RPBP REDUCED PRESSURE BACKFLOW PREVENTER CI CAST IRON SP STATIC PRESSURE XX [OFFICE COPY J CAP CO CLEAN OUT SPEC SPECIFICATION(S) CITY OF T�G�LRD ill UNION COTG CLEAN OUT TO GRADE SQ FT SQUARE FEET REVIEWED FOR CODE COMPLIANCE CONC CONCRETE Approved:� ] I EXPANSION JOINT SS STAINLESS STEEL FLEXIBLE JOINT COND CONDENS - (ER, ING, ATE) STD STANDARD OTC: i j CONCENTRIC REDUCER CONT CONTINU - (E, ED, OUS, ATION) STRUCT STRUCTURAL Permit #• y�-j,or.� q-p fl �'3 �� ECCENTRIC REDUCER STRAIGHT INVERT CU FT CUBIC FEET SYS SYSTEM 0 dB DECIBEL Address: j zo 1:),„ `�;` I-) �`f JONATHAN DUNN,ARCHITECT ECCENTRIC REDUCER STRAIGHT CROWN TEMP TEMPERATURE r Suite#: PERMIT SET DRY BULB TONS TONS OF REFRIGERATION 05.11.17 I STRAINERS/FILTERS Y-PATTERN W/ PLUG DB By: ~�-� Date: 7_ '. C� DDC DIRECT DIGITAL CONTROL(S) TSP TOTAL STATIC PRESSURE REV DESCRIPTION DATE I 14c7 STRAINERS/FILTERS Y-PATTERN W/ BLOWOFF ANCHOR DEG DEGREE TSTAT THERMOSTAT 1 R 2ERREVISION 06.13.17 DEMO DEMOLISH(ED) TYP TYPICAL GUIDE DIA DIAMETER a rJ AV AAV AUTOMATIC AIR VENT VAC VACUUM DN DOWN VAV VARIABLE AIR VOLUME (BOX/UNIT/SYSTEM) re) TPETE'S PLUG DS DOWNSPOUT `� MAV MANUAL AIR VENT VD VOLUME DAMPER REA EACH VEL VELOCITY o RISE EAT ENTERING AIR TEMPERATURE VENT VENTILATION N TEE EFF EFFICIENCY VALIDITY OF PERMIT 0) *— VFD VARIABLE FREQUENCY DRIVE THE ISSUANCE OF A PERMIT TEE, OUTLET UP ELEV ELEVATION VOL VOLUME BASED ON CONSTRUCTION in oa - TEE, OUTLET DOWN ELEC ELECTRIC(AL) VTR VENT THROUGH ROOF DOCUMENTS AND OTHER DATA SHALL NOT PREVENT o f•� ( ELBOW ENT ENTERING VVT VARIABLE VOLUME AND TEMPERATURE THE CODE OFFICIAL FROM w' or ELBOW, OUTLET UP EQUIP EQUIPMENT W/ WITH REQUIRING THE CORRECTION ar-- j e—•— ELBOW, OUTLET DOWN ESP EXTERNAL STATIC PRESSURE W WASTE/WATT OF ERRORS. 05EC rc o co / AND/OR EWT ENTERING WATER TEMPERATURE WB WET BULB 6915 SW MACADAM AVE. ccLLID Y j CENTER LINE EXH EXHAUST (AIR} WPD WATER PRESSURE DROP SUITE 200 Y W DIAMETER PHASE EXIST EXISTING PORTLAND, OREGON 97219 0 Q/ / WT WEIGHT PHONE: 503.892.1188 FAX: . .�3 # NUMBER POUNDS F FAHRENHEIT ZD ZONE DAMPER KE S ASSOCIATES , SSOCIATES , INC . mMECHANICAL 1-p CONTACT...Brendan Arnold � DNSLILTIND ENGINEERS o _I \ 1 \ / \ / engireering@mke-inc.com MECHANICAL AND ELECTRICAL SYSTEMS TITLE SHEET o 0_x II OUTSIDE AIR VENTILATION SINGLE ZONE SYSTEMS Az Pz RP RA Vez EZ Voz NATURAL VENTILATION COMMENTS ROOM ROOM OCCUPANT CODE MAX. ACTUAL VENTILATION AREA OUTDOOR BREATING ZONE AIR ZONE OUTDOOR EXHAUST EXHAUST YES AREA AREA DESCRIPTION AREA DENSITY OCCUPANCY OCCUPANCY FACTOR AIR RATE VENTILATION DISTRIBUTION AIRFLOW AIRFLOW RATE AIRFLOW OR REQUIRED AVAILABLE (SF) (PEOPLE/1000 SF) (PEOPLE) (PEOPLE) (CFM/PERSON) (CFM/SF) (CFM) EFFECTIVENESS (CFM) (CFM/SF) (CFM) NO (SF) (SF) WOODBLOCK ARCHITECTURE, INC. ATM ROOM 69 5 1 1 5.0 0.06 10 0.8 13107 SE WASHINGTON STREET,SUITE 250 NO N/A 0 PORTLAND.OR I 97214 I P 503.889.0804 BREAK ROOM 156 0 0 0 0.8 0 0 NO NIA 0 CONFERENCE ROOM 134 50 7 7 5.0 0.06 44 0.8 55 0 NO N/A 0 p PRgcF IT ROOM 48 4 1 1 5.0 0.06 8 0.8 10 0 NO N/A 0 ��6>�, G I Et M.>44_ JANITOR 10 - - - - - - - - 0 NO N/A 0 k 77• e LOBBY 540 10 6 6 5.0 0.06 63 0.8 79 0 NO N/A 0 ..['`'"'1''� v}`a' 1 OREGON OFFICE 138 5 1 0.0614 0.8 18 0 NO N/A 0 6� v NE 1 OPEN OFFICE 234 5 2 2 5.0 0.06 25 0.8 32 0 NO N/A 0 �4N c. lk RESTROOM 50 - - - - - - - - 50 NO N/A 0 SAFE DEPOSIT 120 5 1 1 5.0 0,06 13 0.8 17 0 NO N/A 0 EXPIRES 12-St-17 TELLERS 190 30 6 6 5.0 0.06 42 0.8 53 0 NO N/A 0 RECEPTION AREA VIEWING ROOM 43 5 1 1 5.0 0.06 8 0.8 10 0 NO N/A 0 WORK ROOM 169 4 1 1 5.0 0.06 16 0.8 20 0.50 85 NO N/A 0 NOTES: EXHAUST FAN SYMBOL DESCRIPTION SERVICE CFM ESP VOLTAGE PH- HP MCA FLA DRIVE RPM TIP INTERLOCK WHEEL DISCHARGE SONES WEIGHT COMMENTS MARK (IN VIIC} SPEED TYPE (LBS) (FPM) EF-1 IN LINE CARNET FAN BREAK ROOMlRESTROOMIJANITOR 200 0.500 120 1 0 0.71 DIRECT 1,050 HORIZONTAL 3.9 23 DESIGN BASIS: GREENHECK CSP EF-2 CEILING FAN ATM ROOM 150 0.500 120 1 0 0.4 DIRECT 900 HORIZONTAL 4.3 24 DESIGN BASIS: GREENHECK SP NOTES' FAN COIL UNIT SYMBOL DESCRIPTION SERVICE CFM VOLTAGE PH. HP MCA FLA ESP RPM DRIVE TOTAL EAT LAT EWT LWT GPM OPD MINIMUM WEIGHT COMMENTS MARK (IN WC) MBH DBPAS DB/4/VB (CF) (OF) (FT) OSA .(LBS) (`F) ("F) CFM FCU-1 DUCTLESS WALL MOUNT IT ROOM 400 208 1 0 1.0 0.3 - - - 18 - - - - - - 29 NOTES: DESIGN BASIS: PKA-A1BHA4 HomeStreet Bank Tigard Branch GENERAL NOTES: OUTDOOR CONDENSING UNIT 16230 SW Pacific Hwy SYMBOL NOMINAL VOLTAGE PHASE MCA MOCP SUCTION CONDENSING CAPACITY REFRIG. SEER NOISE LOW WEIGHT COMMENTS Tigard,OR 97224 A. ALL DUCTWORK IS TO BE GALVANIZED SHEET METAL UNLESS OTHERWISE NOTED AND MARK TONS TEMP TEMP TO RATING AMBIENT (LBS) CONSTRUCTED TO SMACNA STANDARDS. (JF) (°F) MATCH (DB) CONTROL B. DUCT RUN OUT SIZES ARE SAME AS DIFFUSER OR GRILLE NECK SIZES, UNLESS CU-1 1 5 208 1 13 20 FCU-1 R-410A 15.0 48.0 YES 89 OTHERWISE NOTED. NOTES: DESIGN BASIS MITSUBISHI PUY-A18NHA4 C. COORDINATE DUCTWORK ROUTING WITH OTHER TRADES. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS AND INTERIOR ELEVATIONS FOR EXACT LOCATION OF GRILLES, REGISTERS, DIFFUSERS AND EXPOSED DUCTWORK. COORDINATE LOCATIONS WITH OTHER TRADES AND EXISTING CONDITIONS. D. ALL CEILING DIFFUSERS ARE FOUR-WAY WITH AIR PATTERN CONTROL, UNLESS OTHERWISE NOTED. 1111 1111° Project#17-016 E. DUCTWORK JOINTS AND SEAMS SHALL BE SEALED PER 2014 OEESC. DIFFUSER, REGISTER, AND GRILLE SCHEDULE F. ALL DUCTWORK IS LOW PRESSURE. CONSTRUCT SUPPLY AIR DUCT TO 2 IN WC. CONSTRUCT RETURN AND EXHAUST AIR TO 1 IN WC. SYMBOL TYPE FACE FRAME DAMPER FINISH MODEL# COMMENTS G. PROVIDE REMOTE DUCT VOLUME DAMPER OPERATORS AT ALL HARD OR INACCESSIBLE CEILINGS. SR-1 SUPPLY DOUBLE DEFLECTION SURFACE YES WHITE PRICE 520D CD-1 SUPPLY PERFORATED LAY-IN NOTE 1 WHITE PRICE PDMC H. INSTALL ALL EQUIPMENT PER MANUFACTURERS INSTALLATION REQUIREMENTS. RG-1 RETURN FIXED LOUVER LAY-IN NOTE 1 WHITE PRICE PDDR I. PROVIDE SNUBBERS OR SPRING ISOLATORS ON ALL ROTATING EQUIPMENT. RG-2 RETURN FIXED LOUVER SURFACE YES WHITE PRICE 530D NOTES: JONATHAN DUNN,ARCHITECT J. ALL SUPPLY, RETURN, AND OUTSIDE AIR DUCTS TO BE INSULATED TO R-5 MINIMUM. 1.PROVIDE DAMPER IN DUCT BRANCH TO DIFFUSER PERMIT SET K. PROVIDE A 7 DAY PROGRAMMABLE THERMOSTAT FOR ALL FAN COIL SYSTEMS. SET 05.11.17 THERMOSTAT FOR 5 DEG. DEADBAND AND NIGHT SET BACK DURING UNOCCUPIED REV DESCRIPTION DATE 1 OWNER REVISION 06.13.17 TIMES. 2 PR 02 06.07.19 L. PROVIDE FINAL BALANCING REPORT OF ALL DIFFUSERS, GRILLES AND FANS. m a M. SUPPLY DIFFUSERS, PRICE MODEL PDMC OR EQUIVALENT. N. N N. RETURN AND EXHAUST GRILLES, PRICE MODEL PDDR OR EQUIVALENT. rn 0 0. PROVIDE 5 YEAR WARRANTY ON ALL COMPRESSORS. PROVIDE START UP AND oi WARRANTY INFORMATION TO THE OWNER. rn [V P. ALL REFRIGERANT PIPING TO BE COPPER TUBE TYPE ACR COMPLYING WITH ASTM 280. OR COPPER PIPING TYPE L COMPLYING WITH ASTM B 88. Z o o M 0 . PROVIDE STOP VALVES IN REFRIGERANT PIPING ON INLET AND OUTLET TO EACH LA n COMPRESSOR/CONDENSING UNIT. J R. ALL REFRIGERANT IS NEW R-410A. o 6915 SW MACADAM AVE. Yr-- SUITE 200 . l7 w CO PORTLAND, OREGON 97219 I PHONE: 503.892.1 188 d/ EAX: 503.892.1190 g NA "I • 0 o CONTACT...Brendan Arnold K E B ASSOCIATES , INC . HVAC g I- I] NSULTINO ENGINEERS a a X engineering@mke- nc.com MECHANICAL AND ELECTRICAL SYSTEMS SCHEDULES o © II KEYED NOTES : n 1. CONNECT NEW SUPPLY AND RETURN DUCTS TO (E) DROPS FROM (E) RTU. VERIFY SIZE AND LOCATION OF (E) DUCT DROPS AND PROVIDE REQUIRED TRANSITIONS. 2. LOUVER IN DOOR FOR ATM ROOM VENTILATION. WOODBLOCK ARCHITECTURE, INC. MINIMUM 3.5 SF FREE AREA. 107 SE WASHINGTON STREET.SUITE 250 PORTLAND,OR 197214 I P 503.889.0604 3. EXTEND INSULATED 12x12 DUCT DOWN FROM HOOD TO PLENUM AND CONNECT TO EXHAUST DUCTS. GO PRO-p?. PROVIDE R-8 INSULATION. PROVIDE GREENHECK \ej1, 01 E4-470 j' FABRA HOOD, 8X12 THROAT, 14X18 CURB CAP. '77,9D E 4. LOCATE RETURN GRILLE ABOVE HANGING DECORATIVE , . ,...,C►--�°f� ►amu 4. CEILING. OREGON 2 046% 5. ROUTE 3/4" CONDENSATE DRAIN TO MOP SINK. NVR (A C, 6. ROUTE REFRIGERANT PIPING TO FCU-1. SIDE PER MANUFACTURER REQUIREMENTS. PROVIDE ALL I EXPIRES 12-31-17 NECESSARY COMPONENTS FOR A COMPLETE WORKING SYSTEM. 7. MOUNT UNIT ON ROOF WITH PT WOOD SLEEPERS. SEE ARCHITECTURAL PLANS. 2 8. REBALANCE (E) RTU TO 320 CFM OSA AND 3000 CFM SUPPLY AIR. 9. PROVIDE REVERSE ACTING THERMOSTAT TO 80 DEG F. 10. REPLACE FILTERS WITH MERV 8 POST CONSTRUCTION. 1 ;� 2 3 '1 ,__. B 0 xQt49/ �_.._ I 1 iI I I "0 EXH I \ Mk. / I i 13"0 EXH EXHAUST HOOD 0 / / 4N ROOF 300 M8.0. .__ I ! „i TELLERS I $ I_ 15 y 4 $ 1A -- c..., I / ND/ATM ! UNI. RLR L/ 11. © 13 ] I 80 = WORK --_ W : RA Roam 1 ,,, \24X18 . .. — 1100 \ � ----- uo 151 ---4----r-4, T O fr 8010 ' i I EF-2C9> T JANITOR (E RTU 20 P 149 I -4,-•.- I HomeStreet Bank 8"0 \ i ' Tigard Branch 300 �`` 16230 SW Pacific Hwy _ I A. 1. K) V {Y ,• Tigard,OR 97224 I�-----� LOBBY Ik a I 101 _J /7100 _i_ r IF VIEWLlG { 8 R00.1 _ _I j -106 7— 1 16X8 SR-1I TYPICAL OF 4 I - } I F (E) RTU ON ROOF 400 -"6„0 f _i 1a r Mill 4 12"0 „ M8.0 100 N- ,/ 8"0 _ / 200 : \ / 400 \ 300 TYPICAL i �\ —_._..__ Y -..-- II I1 T BREAK6 I ! 01— ROOM IA_,z-_,, � - 4i4I,� Project#17Oifi GOO I , �00 _. - 4 , ._._, ON ROOF ' I 18” RA I 120" RA' . I rt I.� .I. I I I I I I I ' � „ - 14 0 RA - 4 J 14"O SA .. Eli 16' o SAS 1 I -m II 18"0 SA 16"0 SA f 12TO SA © FCU /� 1 SAFEdIP - /� - - - :I) 1 DEPOSIT• / f OPEN CONF. 1 i 7 ' j 105 • —' O ! LOFFICE —I 1. ___1 . A J OFFICE I —103 \/4 JONATHAN DUNN,ARCHITECT -�--~ I1- L 1 ► I 104 I 1 FIF PERMIT SET C�J T � _ ..._. -! 1- Nr 05.11.17 _1O - --- - - ------ - -- - I REV DESCRIPTION DATE 1 1 OWNER REVISION 06.13.17 2 PR 02 06.07.19 1 a"� $„� 8"52$ C $"� 10"0 300 200 200 200 300 d [ RG-1 TYPICAL TYPICAL CD-1 TYPICAL co 1Ni- I C•i rn 1 0 04 N co 1FLOOR PLAN - HVAC AI_l o� \M2.0 SCALE: 1/4" = 1 '-0" 0 2' 4' 8 J� MP” LA NI- J/ Lii o 6915 SW MACADAM AVE. 1- z z'� SUITE 200 . '7 W Y/ PORTLAND, OREGON 97219 t ,, M2 • O m PHONE: 503.892.1188 low FAX: 503.892.1190 KE 5 ASSOCIATES , INC . o I--3 CONTACT...Brendan Arnold : oNSL1LTING ENGHVAC o of engineering@mke-inc.com MECHANICAL AND ELECTRICAL SYSTEMS FLOOR PLANS o ax 0 1. Wr DRAW BAND STRAP SHEET METAL BAND TO PRREVENT FLEXIBLE DUCT WOODBLOCK ARCHITECTURE, INC. KINKING 107 SE WASHINGTON STREET.SUITE 250 PORTLAND.OR 197214 I P 503.889.0604 FLEXIBLE DUCT 60" 11 MAXIMUM LENGTH nGp p� - Oic ROUND NECK, SIZEc:5`.. <c. 11 it. AS INDICATED ON kit PLAN RETURN DUCT 22X22 6 LB. DENSITY e 1 .., R=1 .5 W , FIBERBOARD PLENUM ANCHOR ROOF CAP .ti - 1/ MANUAL i �� _ ,� FASTEN DIFFUSER TO MANUAL TO CURB W/ S.S. ` OREGON VOLUME J J J J L` CEILING GRID WITH VOLUME SCREWS BIRD SCREEN �,�F� 2a%` DAMPER _ _ — _ – SCREWDAMPER y)NNNIVN. . i a a �''IN C. 4 SEAL CUT EDGES OF 5 i — ! ROOF CURB AND SHEETMETAL FIBERBOARD, TYP. 0 0 0I DUCT COUNTER FLASHING BY EXPIRES 12-31-17 60" MAX. = Z J 6 LB. DENSITY i y _- �,,..�... ,. FIBERBOARD PLENUMi ) SEAL CUT EDGES OF I I ( FLASHING BY b 1+11 9 - 1 4 . - SQUARE NECK, SIZEINSULATION, TYP. FASTEN PLENUM ROOF I I AS INDICATED ON SEE ARCH PLANS \ / 9 b — TO GRILLE WITH / \ FASTEN DIFFUSER TO SCREW ( I I 'ir ' J J_) am CEILING GRID WITH F OM I - - — - - - SCREW -- — — — �<IIi FASTEN PLENUM TO—/ T-BAR CEILINGBACKDRAFT DAMPER DIFFUSER WITH SCREW FASTEN GRILLE TO ANGLE IRON FOR EXHAUST DUCTS DIFFUSER CEILING GRID WITH SCREW LT-BAR CEILING DUCT SUPPORT /y /� 24X24 GRILLE FACE 1 4i NOTES: EXHAUST OR OUTSIDE 1 . DIFFUSER FRAME SHALL MATCH ARCHITECTURAL CEILING TYPE. Y AIR DUCT AS INDICATED 2. IN NON-LAY-IN CEILINGS, PROVIDE 18" X 18" MINIMUM ACCESS PANEL OR REMOTE ON PLANS. ANCHOR OPERATOR FOR BALANCING DAMPER. COORDINATE LOCATION WITH ARCHITECT. AND SEAL OFF INSIDE 3. IF DUCT SIZE IS DIFFERENT FROM DIFFUSER NECK SIZE, PROVIDE TRANSITION CURB. FITTING AT DIFFUSER NECK. 1 DETAIL - CEILING SUPPLY DIFFUSER (2DETAIL - CEILING RETURN /EXHAUST GRILLE 3 i DETAIL - ROOF HOOD m8.0 SCALE: N.T.S. M g.�/ SCALE: N.T.S. m8.0 SCALE: N.T.S. 1 1 1 HomeStreet Bank Tigard Branch 16230 SW Pacific Hwy Tigard,OR 97224 0 Project#17-016 JONATHAN DUNN.ARCHITECT PERMIT SET 05.11.17 REV DESCRIPTION DATE 1 OWNER REVISION 06.13.17 2 PR 02 06.07.19 M 0 co N) cV cn 5 N Q) N O Z O Occ) W� a t` NI- _1/ o 6915 SW MACADAM AVE. Li wtSUITE 200 V / 4/ w PORTLAND, OREGON 97219M8 • O w PHONE: 503.892.1 188 o� FAX: 503.892.1190 0 Luc KE S ASSOCIATES , INC . g o CONTACT...Brendan Arnold OONSULTING ENGINEERS HVAC o oJ/ engineering©mke-inc.corn MECHANICAL AND ELECTRICAL SYSTEMS DETAILS o x igi