Loading...
Plans (8) BU P2019-00184 , N... : a � a JUL E2 4 2015 , "" + �� ,L.„.•.�. t- 141‘14*(/ a W I a, via- ' ' °VIZ CITY OF I IGAF�'_ a ...... .. .... ... . !3[J#�©INC DIV#SIU=V � .O, S 'kris-- °O 4'„'` 0 VALIDITY OF pER��iT THE ISSUANCE Ofi A PERMIT' W.. .BASED O ' .!i.i: ; p LL DOCUMENTS AND OTHER 0 DATA SHALL NOT PREVENT �• "'" , ,,....„ ‘„ g g 3'14;rct.. THE CODE OFFICIAL FROlId ' pEQUIRlNG THE CORRI`CTIpN ..•� - aF ERR �" ......_...... 41.- ' 0�. tkSSC 145.4 i , , g f.- . WASHINGTON SQUARE MALL V grn E CO 's° E«,,,gi_f_t.IL col - • •M. OFFICE a CITY DF TIGAtD z 61 Q 9585WASHINGTON SQUARE RD SPACE NCS. K10 A DOCODE COMPLIANCESW Approved: § -,'1- I OTCs I J - PORTLAND, QR 97223 uJ 3 k r By: `-f1' Date: f, q "NEW MALL C" ZI... . i ABBREVIATIONS PROJECT DATA SITE LOCATION PLAN DETAILED SCOPE OF WORK . PROJECT SCOPE. NEW BOX LUNCH SPACE TENANT BUILD OUT, REMOVE NON-LOAD BEARING INTERIOR WALLS & A.F.F. ABOVE FINISHED FLOOR JT. JOINT 1. PROJECT NAME:. 130X LUNCH # 4647-C WASHINGTON SQUARE MALL A.F.C. ABOVE FINISHED CEILING MFR. MANUFACTURE (R) INSTALL NEW NON-LOAD BEARING WALLS. INSTALL TENANT FIXTURES, LIGHTING & TRACK LIGHTING. REUSE HVAC WITH AC.T. ACOUSTICAL TILE MECH. MECHANIC (AL) 2. PROJECT DESCRIPTION: - CLOTHING SALES (RETAIL) - NEW TENANT BUILD OUT SOME NEW MECHANICAL DUCTS AS PER MECH. SHEETS, WITHIN PREVIOUS TENANT USE/LEASED PREMISES. ADJ. ADJACENT MTh. METAL 3. PROJECT LOCATION:. WASHINGTON SQUARE MALL _.-.... ALT. ALTERNATE MEZZ. MEZZANINE 9585 SW WASHINGTON SQUARE RD. MIN. MINIMUM MINUTE PORTLAND, OR 97223 1-'c'�;;la€tU.1,� < :-:dscori DRAWING INDEX ...�. �. APPROX. APPROXIMATE ( ) ARCH. ARCHITECT (URAL) MISC. MISCELLANEOUS ��t, ,t SHEET DESCRIPTION REV DATE 4. TENANT:. BOX LUNCH Have .Sylvan ..._.....4 BLK. BLOCK N.I.C. NOT IN CONTRACT ' Portland�s�D° , BLKG. BLOCKING N.T.S. NOT TO SCALE 18305 E. SAN JOSE AVENUE Oregon Zoo 1 TO.O TITLE SHEET BD. BOARD NO. or # NUMBER CITY OF INDUSTRY, CALIFORNIA 91748 : .) 2 T1 .0 ARCHITECTURAL SPECIFICATIONS I CLG. CEILING O,F.C.I. OWNER FURNISHED CONTRACTOR PHONE (310) 938-5552 I CLG.HT. CEILING HEIGHT INSTALLED CONTACT: WESTON MARTIN (PROJECT MANAGER) 3 T2.0 ARCHITECTURAL SCHEDULES . CLR. CLEAR (ANCE) O.F.0.1. OWNER FURNISHED OWNER EMAIL: wmartinahottopic.com �lv €Sio 0)01-w:: ...rua•t Park it; - CLO. CLOSET INSTALLED tO COL. COLUMN O,G. ON CENTER (S) 5• LANDLORD: .11411 N. CHM BLVD. i`I 4 D1 .0 DEMOLITION PLAN C.M.U. CONCRETE MASONRY UNIT OPP. OPPOSITE Beaverton CONST. CONSTRUCTION P. L PLASTIC LAMINATE PHOENIX, AZ $502$ ..._...�..,._......._ ........... € ....._.._.£ _�._......_.. COORDINATE PLBG. PLUMBING PHONE # (602) 953-6377 5 Al .0 FLOOR PLAN I.---- COORD. PLYWOOD CONTACT: CHARLIE SIROKMAN (TENANT COORDINATOR) rz.isi 6 A2.O REFLECTED CEILING PLAN ' PWD. LYWO D ' CORR. CORRIDOR EMAIL: chorlene.s€rokman@rnacerich,com ". '° CTR. CENTER PVC. POLYVINYL CHLORIDE •,,i Oaks A „Th € ar t t�€ 7 A3.0 FIXTURE/ FLOOR FINISH PLAN C.T. CERAMIC TILE P.M. PROJECT MANAGER 6, TENANT'S ARCHITECT: ARCVISION INC. 8 A3. 1 FIXTURE DETAILS ,............. ........____......._.vV.. I _. DET. DETAIL R.A. RETURN AIR 1950 CRAIG RD. - SUITE 300 NAG. DIAGONAL R.C.P. REFLECTED CEILING PLAN ST. LOUIS, MO 63146 9 A4.0 SALES AREA ELEVATIONS C4 - DIA. DIAMETER REF. REFERENCE PHONE # (800) 489-2233 G;rc,cr 1 0 A4. 1 TYPICAL FITTING ROOM DETAILS DIF. DIFFUSER REG. REGISTER CONTACT: AUTUMN BRIGHTWELL F�� Squarehitiorc 11 A4.2 ELEVATIONS AND TOILET DETAILS Square DIM, DIMENSION REINF. REINFORCE (D), (INC) 7. BUILDING DEPARTMENT: CITY OF TIGARD BUILDING DIVISION tashington z Ie:.lrlpir,grlialf 12 A5.0 STOREFRONT PLAN & ELEVATION �DISP. DISPENSER REQ'D. (REQ.)REQUIRED €€3u::x<ty�Iw 13125 SW HALL BLVD. • DR. DOOR REV. REVISION (S), REVISED 1 3 A7.0 SECTIONS & DETAILS14' TIGARD, OR 97223 { ''` Meizter Milwv ��k DWG. DRAWING R.O. ROUGH OPENING PHONE # (503) 718-2439 CC ELEC. ELECTRICAL SHT. SHEET Creek:St ,.. iiii� irya CONTACT: PLAN REVIEWER :State 14 SH � 1 STORAGE SHELVING DETAILS � �_... �• E.P. ELECTRIC PANEL SIM. SIMILAR = ELEV. ELEVATION S.C. SOLID CORE E.W.C. ELECTRIC WATER COOLER S.S. STAINLESS STEEL 8. GOVERNING CODES: ALL WORK SHALL BE IN CONFORMANCE WITH, BUT NOT LIMITED TO, THE REQUIREMENTS OF THE FOLLOWING AND ANY OTHER STATE AND LOCAL 15 M 1 .0 MECHANICAL PLAN .. •.--.. cam.. ... ...... EXIST EXISTING STD. STANDARD CODES HAVING JURISDICTION. 1 6 M2.0 MECHANICAL CALCS & SPECIFICATIONS Z F- (Ni L.. EQUIP. EQUIPMENT STL. STEEL .... .. EXH. EXHAUST STO. STORAGE BUILDING: 2014 OREGON STRUCTURAL SPECIALTY CODE (OSSC) SPACE LOCATION PLAN (2 ,t;It a` EXP. JT. EXPANSION JOINT S.D. STORM DRAIN PLUMBING: 2017 OREGON PLUMBING SPECIALTY CODE (OPSC) 1 7 El .0 ELECTRICAL POWER PLAN 8rn 1 0.•�.........• FIN. FINISH (ED) STRUCT. STRUCTURAL < I - MECHANICAL•2014 OREGON MECHANICAL SPECIALTY CODE (OMSC) 18 E2.0 ELECTRICAL LIGHTING PLAN F.E. FIRE EXTINGUISHER SUSP. SUSPENDED FIRE: 2014 OREGON FIRE CODE (OFC) LEVEL: 1 OF 1 �T" w FP. FIREPR04FING T.B.D. TO BE DETERMINED JCPenney = - 19 E3.0 ELECTRICAL DETAILS AND SCHEDULES F.D. FLOOR DRAW ELECTRICAL: 2017 OREGON ELECTRICAL SPECIALTY CODE (OESC) _........... TEL TELEPHONE ENERGY: 2014 OREGON ENERGY EFFICIENCY SPECIALTY CODE (OEESC) I z,,.-4-, 20 E4.0 ELECTRICAL SPECIFICATIONS _ FLUOR. FLUORESCENT TS. TUBE STEEL - "I- l • • C[ ZI fQ F.R.T. FIRE RETARDANT TREATED TYP. TYPICAL 9 CONSTRUCTION TYPE: 11--8 / (� Caf � -0 FURR. FURRED (ING) U.N.O. UNLESS NOTED OTHERWISEIII 10. OCCUPANCY: M (MERCANTILE) _. / � 7- ., __ GA. GAUGE VERT. VERTICAL I GALV. GALVANIZED I G.C. GENERAL CONTRACTOR VEST. VESTIBULE 11. GROSS LEASED PREMISES: . . . . 2,265 SQ. FT. V.C.T. VINYL COMPOSITION TILE DICK'S J ` J _a_ GYP, BD, GYPSUM BOARD V.I.F. VERIFY IN FIELD 12. OCCUPANCY LOADS., SALES FLOOR 1,825 SQ. F t DIVIDED BY 30 = 61 € ! H.V.kC, HEATING/VENTILATION/ W.C. WATER CLOSET SPORTING J y _ _ ; AIR CONDITIONING STOCK ROOM 440 SQ. F t DIVIDED BY 300 = 2 GOODS H.C. HOLLOW CORE WP. WATERPROOF(ING) TOTAL OCCUPANTS - 63 1 € € 1 l- - *. MALL PROVIDED RESTROOMS I I H.M. HOLLOW METAL WEATHER STRIPPING * TOTAL NUMBER OF EMPLOYEES AT ONE TIME = 3 I- ` '. DISTANCE: -290 g I HORIZ. HORIZONTAL W/ WITH YES IXI NO ❑ • W/0 WITHOUT { - ' j _ 3 i I H.W. HOT WATER 13. ARE SUPPRESSION SYSTEM. ..K • IN.(") INCH WD. WOOD �-`.I. r' . I L__,. .[7, I.Jai . INT. INTERIOR 14. MISCELLANEOUS NOTES: TENANT'S GENERAL CONTRACTOR SHALL VISIT THE PREMISES AND VERIFY 1 1 ALL EXISTING CONDITIONS PRIOR TO START OF CONSTRUCTION AND SHALL :P U • � 1 1 REPORT ALL DISCREPANCIES TO TENANT'S ARCHITECT. TENANT'S GENERAL I scncEH° "' S; GRAPHIC SYMBOLS CONTRACTOR SHALL CONFORM TO ALL REQUIREMENTS REGARDING I CONSTRUCTION PROCEDURES, INSURANCE, ETC., AS SET FORTH BY THE - 4 LANDLORD. ^` ' ., . a _ ': :-• , I I DETAIL NUMBER ROOM NUMBER BON MACY'S I r- } BOX LUNCH PRE/POST PUNCHLIST gh 15. FIRE SPRINKLERS:. AN AUTOMATIC FIRE SPRINKLER SYSTEM IS EXISTING WITHIN THIS SPACE. THE "• .: E£ .'.. CONTRACTOR SHALL REWORK AND MODIFY FOR NEW ROOM LAYOUT & CEILING SHEET WHERE " KEY NOTE O2 HEIGHTS IN CONFORMANCE WITH N.F.P.A. 13 STANDARDS & LOCAL CODES & '.:7 '�` t 1. DOES FRONT DOOR AND SACK DOOR HAVE A 7-PIN CYLINDER FOR BL PROVIDED CORES? `' I III 2. IF NOT ALREADY EXISTING, GC TO FURNISH AND INSTALL A PEEP HOLE AT 5'-O" AFF IN BACK DOOR LLI DETAIL IS SHOWN REGULATIONS. ALL WORK SHALL BE DONE BY A QUALIFIED SPRINKLER _ 3 PARTITION TYPE CONTRACTOR WHO SHALL DESIGN & PREPARE SHOP DRAWINGS & SUBMIT 1,., �� -- L - .. NORDSTROM L- - 3. GC TO INSTALL A PRY PLATE ON BACKDOOR IF NOT EXISTING LU f;' -� '�cob('5- 4. GC TO FURNISH AND INSTALL A NEW BATTERY FOR THE DETEX IN BACK DOOR o •w__•.._ SECTION CUT © THEM TO THE LANDLORD FOR APPROVAL PRIOR TO FABRICATION & G o �, 0:1 Z A100 INSTALLATION. SPRINKLER CONTRACTOR SHALL BE LANDLORD APPROVED. HEADS Th, ,f [ �Y . 5. GC TO INSTALL 2 INK TAG DETACHERS IN CASHWRAP Cr) o a DOOR NUMBER W CEILING TILES TO BE CENTERED IN TILES WHEN IN A PUBLIC AREA. [ r 6. CORK BOARDS TO BE INSTALLED IN THE BACK ROOM/HALLWAY 8Y GC AT STORE OPERATIONS DISCRETION 7 1 7. ADA STICKERS AND SIGNS TO BE INSTALLED BY GC ON CASHWRAP, FRONT WINDOW, AND FITTING ROOM z 00 Lu. 4 .. 8. LOCKING COVER ON THERMOSTAT W n . BUILDING CROSS :II'. SECTION A100 ELEVATION BENCHMARK TIE. r . , 9. GC TO SUPPLY 8 KEYS FOR FITTING ROOM DOORS (IF MULTIPLE FITTING ROOMS, EACH DOOR IS TO BE KEYED ALIKE) § _ N r FERE SPRINKLER DRAWINGS AND HYDRAULIC CALCULATIONS SHALL BE SUBMITTED BY 10. GC TO CAULK AROUND FITTING ROOM BENCHES AND BASE BOARDS WITH CLEAR SILICONE Q c, N CD '- FIRE • THE LICENSED FIRE SPRINKLER CONTRACTOR TO THE GOVERNING MUNICIPALITY FOR -` -----� `- 11. IF WE ARE REUSING AN ADA FITTING ROOM, GC TO ADD A FITTING ROOM HOOK AT 48" NEXT TO FITTING ROOM BENCH ELEVATION MOO4REVISION NUMBER Q APPROVAL PRIOR TO ANY WORK BEING PERFORMED. • 12. SLATWALL SCREW CHECK. MAKE SURE HARDWARE SLIDES FLUSH ALONG SLATS WHERE SCREW HEADS STICK OUT. Tomo Uri OF TIGARD Approved by Planning Date: 7-1-9-11__ _ Initials: is DIECUTION SENO DEMOLITION; PART A. REMOVE LOOSE MA AND FOREIGN MATTER WHICH MIGHT IMPAIR ADHESION OF SEALANT. ACCISS MEM - - �w�" " 00700 GENERAL CglyENERAL�; ANY AND ALL DEMOLITION REQUIRED TO COMPLETE CONSTRUCTION FOR THIS PROJECT MUST BE CONSIDERED PART OF THIS CONTRACT 1. G.C. SHALL PROVIDE AND INSTALL ACCESS PANELS AS REQUIRED BY LANDLORD AND SITE CONDITIONS (COORDINATE SIZE t� . ..). ili- AS INDICATED IN THE AID DOCUMENT jA2D1 GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION' 1987 EDITION. � "W AND SHOULD BE EXECUTED IN ACCORDANCE WITH THE LANDLORD'S REQUIREMENTS. REQUIREMENTS. B. CLEAN AND PRIME JOINTS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. REQUIREMENTS, NUMBER OF PANELS REQUIRED AND LOCATIONS WITH LANDLORD AND All MECHANICAL TRADES). �� c.,..-...>�; 2 cd-116 00810 MODIFICATIONS TO GENERAL CONDITIONS; THE CONSTRUCTION DOCUMENTS INDICATED EXISTING CONDITIONS, WALLS, AREAS TO REMAIN BUT THE ARCHITECT DOES NOT CERTIFY -n-- .� THAT ALL DEMOLITION WORK IS INDICATED ON THE PLANS. ANY ITEMS INDICATED AS EXISTING, TO REMAIN, HAVE TO BE INSPECTED C. PROTECT ELEMENTS SURROUNDING THE WORK OF THIS SECTION FROM NAGE OR DISFIGURATION. 2. ACCESS PANELS SHALL BE FLUSH TYPE (NO EXPOSED FLANGES) STYLE "DW' AS MANUFACTURED BY: MILCOR, 1101 EAST - � ARTICLE 4 BY THE GENERAL CONTRACTOR TO DETERMINE IF ANY OF THESE ITEMS CAN BE REUSED. AT THE END OF CONSTRUCTION, THE KIBBY, LIMA, OHIO, 45804. PHONE NUMBER: 419-227-6899 (SIZE AS REQUIRED) .». ' o o 4.4.1 ADD THE FOLLOWING: UTILITIES SHALL INCLUDE A JOB TELEPHONE TO BE INSTALLED WITHIN FIVE (5) WORKING DAYS MLR EXISTING WALLS, AREAS, ETC., SHOULD BE LIKE-NEW CONSTRUCTION. ALL DEMOLISHED WORK SHALL BE REMOVED FROM THE PROJECT D. INSTALL SEALANT IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. Vi µ COMMENCEMENT OF THE WORK. COORDINATE WITH TENANT UTILITY MANAGER. SITE AND LEGALLY DISPOSED OF. NO CONSTRUCTION MATERIALS ARE TO BE DISPOSED OF IN THE MALL TRASH RECEPTACLES OR 3. PANELS TO BE FACTORY PRIMED (WHITE) READY TO RECEIVE FINAL FINISH (PAINT) BY G.C. -A,„,.._ r DUMPSTERS WITHOUT LANDLORD'S PRIOR APPROVAL. REFER TO DEMOLITION PLAN NOTES. E. INSTALL JOINT BACKING. .. 4.. , II I 4.10.1 ADD THE FOLLOWING: CONTRACTOR SHALL SUPPLY PROJECT MANAGER WITH A COMPLETE LIST OF ALL SUB-CONTRACTORS 09300 PORCELAIN TILE; _ _ KE \°� , INVOLVED WITH THE WORK, (NAME, ADDRESS AND TELEPHONE NUMBER) WITH SECOND APPLICATION FOR PAYMENT . SEND TWO F. APPLY SEALANT WITHIN RECOMMENDED APPLICATION TEMPERATURE RANGES. CONSULT MANUFACTURER WHEN SEALANT CANNOT SECTION 1-PRODUCTS COPIES TO THE HOME OFFICE, ATTENTION STORE PLANNING. HVAC AND H.W. HEATER INFORMATION MUST BE NOTED. REFER TO 1. SCOPE: FURNISH EQUIPMENT AND PERFORM LABOR REQUIRED TO EXECUTE THIS WORK AS INDICATED ON THE DRAWINGS AS BE APPLIED WITHIN THESE TEMPERATURE RANGES. .o--. -- ---- ---a----------- TENANT FORM. SPECIFIED AND AS NECESSARY TO COMPLETE THE CONTRACT, INCLUDING, BUT NOT LIMITED TO, THESE MAJOR ITEMS. 1.1 CERAMIC TILE SHALL CONFORM TO REQUIREMENTS OF ANSI A137.1-1988 -Aril ` 08210 WOOD DOORS: TYPE: CERAMIC TILE, REFER TO MATERIALS SCHEDULE. i - 0101 Q SUMMARY OF WORK; A. PROTECTION OF EXISTING WORK TO REMAIN. SIZE: CERAMIC TILE SHALL BE MANUFACTURED TO SPECIFIC SIZE AFTER FIRING AND SHALL BE NOMINAL SIZE, REFER TOp 0 ALL INTERIOR WOOD DOORS SHALL BE SOLID CORE (COORDINATE WITH DOOR SCHEDULE) FLUSH CONSTRUCTION, OF THE MATERIALS SCHEDULE. WORK OF CONTRACT CAN BE SUMMARIZED BY REFERENCE TO THE CONTRACT, GENERAL CONDMONS, SPECIFICATIONS, DRAWINGS, B. DEMOLISH EXISTING CONSTRUCTION WHERE INDICATED ON THE DRAWINGS AND WHERE REQUIRED BY JOB CONDITIONS. DIMENSIONS SHOWN, AND SHALL MEET OR EXCEED THE ANSI NWSA INDUSTRY STANDARD I.S. SERIES & AWI QUALITY STANDARD FOR ADDENDA AND MODIFICATIONS TO THESE DOCUMENTS ISSUED SUBSEQUENT TO THE INITIAL PRINTING OF SAME. ARCHITECTURAL FLUSH DOORS. / / THICKNESS: CERAMIC TILE SHALL BE MANUFACTURED TO SPECIFIC THICKNESS AFTER FIRING AND SHALL BE NOMINAL, REFER TO a C. REMOVAL OF PARTITIONS, DOORS, FLOOR COVERINGS, AND CEILINGS. MATERIALS SCHEDULE. A RESPONSIBILITY SCHEDULE IS INDICATED ON THE PLANS. IT INCLUDES COORDINATION WITH OTHER WORK PERFORMED BY SEPARATE D. REMOVAL AND CAPPING OF MECHANICAL AND ELECTRICAL FIXTURES AND SERVICES. DOORSKIN FOR PAINTED AND VINYL COVERED SURFACES SHALL BE OF PAINT GRADE. OVERALL THICKNESS OF DOORSKIN SHALL BE COLOR: REFER TO MATERIALS SCHEDULE. 0 - CONTRACTORS OF THE PROJECT. 1/8" AND SHOULD BE BELT SANDED FOR PAINT FINISH. FINAL SANDING BY FIELD FINISHER. WHEN REQUIRED BY CODE, FIRE 1.2 SETTING MATERIALS: USE APPROPRIATE INSTALLATION MORTARS ACCORDING TO ANSI A118. SERIES OR A136.1992 TYPE 1. (. ) -..g... E. DEBRIS REMOVAL AND DISPOSAL. DOORS SHOULD HAVE THE REQUIRED FIRE RATING. CONTRACTOR D 11Y 1.3 GROUTING MATERIALS: SELECT GROUT PER ANSI A118.3, A118.5, A118.6 OR A118.8- 1992. POLYBLEND NON-SANDED GROUT. N - GENERAL CONTRACTOR SHALL PROVIDE AND PAY FOR: LABOR, MATERIAL, EQUIPMENT, TOOLS, CONSTRUCTION EQUIPMENT, MACHINERY, F. REMOVAL OR CORING OF PORTIONS OF THE EXISTING CONCRETE SLAB AS REQUIRED FOR SERVICE AND EQUIPMENT LINE WOOD FRAMES: MANUF. : BONSAL CO. COLOR: HONEY. ' WATER, HEAT AND UTILITIES REQUIRED FOR CONSTRUCTION AS WELL AS ANY OTHER FACILITIES AND SERVICE NECESSARY FOR PROPER INSTALLATION. PATCHING SHALT_ BE ACCEPTABLE TO THE POINT THAT THE FINISH WILL ACCEPT SCHEDULED FINISH MATERIAL WITH EXAMINE DOOR FRAMES AND VERIFY THAT THE FRAMES ARE EHE CORRECT TYPE AND HAVE BEEN INSTALLED AS REQUIRED FOR - EXECUTION AND COMPLETION OF THE WORK. NO NOTICEABLE EFFECT OF AN ALTERATION HAVING BEEN MADE. PROPER HANGING OF CORRESPONDING DOORS. ALIGN AND FIT THE DOORS IN THE FRAMES WITH THE FOLLOWING UNIFORM _.�m 1.4 WATERPROOFING/ANTI-FRACTURE MEMBRANE: SELECT PER ANSI A118.10-1993 AS REQUIRED. € G. REMOVAL OF ANY EXISTING STOREFRONT, INCLUDING OVERHEAD ROLL-UP GRILLE. CLEARANCES AND BEVELS. TRIM STILES AND RAILS ONLY TO THE EXTENT PERMITTED BY LABELING AGENCY. GENERAL CONTRACTOR SHALL SECURE AND PAY FOR THE FOLLOWING ITEMS, NECESSARY FOR EXECUTION AND COMPLETION OF THE 1.5 GROUT SEALER: BONSAL OR EQUAL. ... WORK, AND AS APPLICABLE AT THE TIME OF RECEIPT OF BIDS: PERMITS, FEES, LICENSES, BONDS AND INSURANCE'S REQUIRED BY FOR NON-RATED DOORS, PROVIDE CLEARANCES OF 1/8' AT JAMBS AND HEADS, AND 1/8" FROM THE BOTTOM OF THE DOOR TO g 2. GENERAL REQUIREMENTS THE TOP OF THE FINISH OR COVERING. SECTION 2-INSTALLATION - .w....... LOCAL AUTHORITIES AND/OR LANDLORD. FOR FIRE-RATED DOORS, PROVIDE CLEARANCES AND CORRESPONDING FIRE-RATED FRAMES IN ACCORDANCE WITH REQUIREMENTS m IL A. THE CONTRACTORS SHALL BE FULLY RESPONSIBLE FOR THE ADEQUACY AND INSTALLATION OF ALL TEMPORARY SHORING SYSTEMS OF NEPA NO. 80 2.1 ACCEPTABILITY OF SURFACES USED DURING THE REMOVING OF ALL STRUCTURAL ELEMENTS. A. BEFORE TILING, VERIFY THAT ALL SURFACES TO BE TILED ARE STRUCTURALLY SOUND TRUE TO PLANE, AND FALL WITHIN .. .....tn. EXISTING DOORS: MAXIMUM VARIATIONS SHOWN BELOW: REGULATORY AGENCIES: Z,._..�¢._ B. THE DRAWINGS DO NOT NECESSARILY INDICATE THE FULL EXTENT OF THE WORK REQUIRED TO BE PERFORMED. INSPECT THE WHEN EXISTING DOOR IS TO REMAIN IN SERVICE, DOOR AND FRAME MUST BE RAISED 3/8" FROM EXISTING FLOOR TO PROVIDE WALLS FLOORS 1/8" IN 8' 1/8" IN 10' ALL WORK PERFORMED SHALL BE IN ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS AND ORDINANCES HAVING JURISDICTION, EXISTING CONSTRUCTION CAREFULLY TO DETERMINE THE FULL EXTENT OF WORK TO BE PERFORMED AND THE PROBLEMS FOR DOOR CLEARANCE IF OVER NEW CARPET. REPORT ALL UNACCEPTABLE SURFACES TO THE ARCHITECT IN WRITING, AND DO NOT TILE SUCH SURFACES UNTIL THEY ARE 01-- 2 " AND IN ACCORDANCE WITH THE 'DESIGN CRITERIA FOR TENANT WORK 0 ISSUED BY THE LANDLORD. INVOLVED. NO EXTRA COMPENSATION WILL BE ALLOWED BECAUSE OF FAILURE TO ESTIMATE THE FULL EXTENT OF THE WORK OR A. KEYING LEVELED ENOUGH TO MEET ABOVE REQUIREMENTS. i �t FOR ANY CONTINGENCY ALLOWANCES. B. BEFORE TILING, ALl SURFACES MUST BE FREE OF CURING COMPOUNDS, OIL, GREASE, WAX, DIRT, DUST, FORM RELEASES RffETRE)rCE STANDARDS: FOR GENERAL CONTRACTOR TO COORDINATE KEYING AND WASTER KEYING WITH CONSTRUCTION MANAGER. OR OTHER SUBSTANCES THAT WOULD INTERFERE WITH PROPER BOND OF SETTING MATERIALS- IF TILE IS INSTALLED BY COMPLY WITH THE APPLICABLE SPECIFICATIONS AND STANDARDS OF UL, ASTM, ANSI, AWI, NEMA, AIA AND ALL OTHER STANDARDS OF 2 MANUFACTURERS ASSOCIATIONS. C. ALL WORK SHALL BE PERFORMED BY SKILLED AND PROPERLY EQUIPPED PERSONNEL DEMOLITION AND REMOVAL OF ITS ITEMS 2. GENERAL CONTRACTOR TO INSTALL CONSTRUCTION CORES DURING CONSTRUCTION AND REPLACE WITH PERMANENT THE THIN-SET METHOD, CONCRETE SLABS SHALL BE STEEL TROWEL OR LIGHT BROOM FINISH. U SCAFFOLD HIGH OR HIGHER SHALL BE LOWERED BY CONTROLLED METHODS, NOT BY THROWING OR DROPPING. PERFORM CUTTING S QUALITY ASSURVICE: AND STRIPPING SO THAT THE WORK TO REMAIN IS UNDAMAGED AND IN SUCH A MANNER THAT NEW WORK CAN BE PROPERLY BE AT END OF JOB PRIOR TO TURN-OVER. 2.2 SETTING METHODS: COMPLY WITH APPROPRIATE ANSI A108 SPECIFICATION CURRENT AND TILE COUNCIL OF AMERICA HANDBOOK IN.L Q c) E THE CONTRACTOR ASSUMES OVERALL RESPONSIBILITY FOR THE WORK OF THIS PROJECT TO ASSURE THAT ALL ASSEMBLES, COMPONENTS CONNECTED WITH IT. FOR APPROPRIATE METHOD OF INSTALLATION FOR EACH SPECIFICATION. FOR ADHESIVE MORTAR APPLICATION USE FOLLOWING: " AND PARTS INDICATED OR REQUIRED COMPLY WITH CONTRACT DOCUMENTS. ANY SUBSTITUTIONS MADE BY THE CONTRACTOR WITHOUT B. PROVIDE COMMERCIAL GRADE HARDWARE, COMPLYING WITH PROJECT SPECIFICATIONS, IN SETS ACCORDING TO THE SCHEDULE WITH FLAT SIDE OF TROWEL, KEY MORTAR INTO SUBSTRATE. USING THE APPROPRIATE SIZE TROWEL, COMB MORTAR IN ONE HEREIN AND ON DOOR SCHEDULE DRAWING. REFER TO DOOR SCHEDULE HARDWARE. DIRECTION WITH NOTCHED SIDE OF TROWEL. SET TILE WITH A SLIDING MOTION, PERPENDICULAR TO THE MORTAR x - -' PRIOR WRITTEN APPROVAL OF THE OWNER WILL BE REJECTED AND REPLACED AT THE CONTRACTOR'S EXPENSE. D. UNFORESEEN CONDITIONS: INCLUDE IN THE BASE BID MISCELLANEOUS CUTTING AND PATCHING NECESSITATED AS A RESULT OF COVERAGE AS POSSIBLE OF MORTAR TO TILE. RIDGES. OBTAIN AS NEAR AS 100 MORTAR MUST BE SUFFICIENTLY UNFORESEEN CONDITIONS AND THE REWORKING OF ABUTTING SURFACES AS REQUIRED TO MAKE NEW WORK JOIN AND MATCH PORT 2 - PREPARATION / ONION DISTRIBUTED TO GIVE FULL SUPPORT UNDER ALL CORNERS AND EDGES OF THE TILE. PERIODICALLY, REMOVE SHEETS OR THE CONTRACTOR ALSO ASSURES THAT ALL COMPONENTS, SPECIFIED OR REQUIRED TO SATISFACTORILY COMPLETE THE INSTALLATION ARE COMPATIBLE WITH EACH OTHER, WITH ADJOINING SUBSTRATES, MATERIALS AND WORK BY OTHER TRADES, AND WITH THE CONDITIONS OF EXISTING SURFACES TO REMAIN. NO EXTRA PAYMENTS BASED ON THE PLEA OF UNFORESEEN CONDITIONS WILL BE ALLOWED. A COORDINATE THE WORK WITH OTHER DIRECTLY AFFECTED SECTIONS INVOLVING FABRICATION OF WALL INT. REINFORCEMENT INDIVIDUAL TILES TO ASSURE PROPER BOND COVERAGE CONSISTENT WfTH INDUSTRY SPECIFICATIONS. INSTALLATION AND EXPECTED USE. E. G.C. TO COORDINATE WITH THE LANDLORD ALL WORK THAT MAY EFFECT NORMAL DAILY OPERATIONS OF THE LANDLORD PREMISES FOR DOOR HARDWARE & RECESSED ITEMS. 2.3 MAX. GROUT JOINT = 1/8'. AND COMPLY WITH ALL RESTRICTIONS THE LANDLORD MAY HAVE ON DEMOLITION AND/ORCONSTRUCTION SCHEDULES. COOPERATE B. VERIFY THAT DOORS AND FRAMES ARE READY TO RECEIVE WORK AND DIMENSIONS ARE AS INDICATED. FIRE-RATED CONSTRUCTOR FULLY TO THE END THAT CERTAIN FACILITIES AND SERVICES ARE MAINTAINED IN OPERATION UNTIL IMMEDIATELY BEFORE THEIR 2.4 EXPANSION JOINTS: INSTALL ARCHITECTURALLY DESIGNED EXPANSION JOINTS AS PER CURRENT TCA DETAIL EJ171. 4 WHEREVER A FIRE RESISTANCE CLASSIFICATION IS INDICATED OR REQUIRED FOR CONSTRUCTION, PROVIDE MATERIALS, ACCESSORIES AND REMOVAL IS REQUIRED TO PERMIT INSTALLATION OF NEW WORK. PREFABRICATED EXPANSION JOINT STRIPS CAN ALSO BE USED WHEN SUITABLE. APPLICATION PROCEDURES WHICH COMPLY WITH THE REQUIREMENTS OF UL "FIRE RESISTANCE INDEX' FOR THE UL DESIGN NUMBERS C. INSTALL HARDWARE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. CORRESPONDING WITH THE CONSTRUCTION ASSEMBLIES INDICATED. F. NOISE CONTROL: CARRY ON ALL WORK INA MANNER WHICH WILL PRODUCE THE LEAST AMOUNT OF NOISE. INSTRUCT All 2.5 GROUTING METHODS: FOLLOW EXACTLY GROUT MANUFACTURES INSTRUCTIONS AND COMPLY WITH APPROPRIATE ANSI A10$ 01030 SHORT / DAMAGED FREIGHT; D. USE TEMPLATES PROVIDED BY HARDWARE ITEM MANUFACTURER. SPECIFICATION DEPENDING ON TYPE OF GROUT SELECTED. GROUTING IS NOT COMPLETE UNTIL ALL GROUT HAZE AND WORKERS IN NOISE CONTROL PROCEDURES. RESIDUES ARE REMOVED FROM THE SURFACE OF THE TILE. 1° 3. PROTECTION OF PERSONNEL: ERECT SIGNS, BARRICADES AND SUCH OTHER FORMS OF WARNING AS MAY BE REQUIRED TO PREVENT E. WHEREVER CUTTING AND FITTING IS REQUIRED TO INSTALL HARDWARE ONTO OR INTO SURFACES WHICH ARE LATER TO BE "' INDICATED BELOW ARE INSTRUCTIONS ON HOW TO HANDLE SHORT, OR DAMAGED FREIGHT: PERSONNEL FROM PUTTING THEMSELVES IN THE WAY OF INJURY. PAINTED OR OTHERWISE FINISHED, INSTALL EACH ITEM COMPLETELY, THEN REMOVE AND STORE DURING APPLICATION OF 2.6 GROUT SEALER: COMPLY WITH MANUFACTURES INSTRUCTIONS AND APPROPRIATE ANSI SPECIFICATIONS FOR PRODUCT SELECTED. 4. MECHANICAL, ELECTRICAL, AND PLUMBING FINISHES. REINSTALL UPON COMPLETION OF FINISHING OPERATIONS. SPACE FASTENERS AND ANCHORAGES AS INDICATED ...._....._ ` `" " 1. BEFORE SIGNING THE FREIGHT BILL, NOTE SPECIFICALLY THE REM(S) DAMAGED OR MISSING i.e., ONE LIGHT FIXTURE, TWO PIECES OR IN ACCORDANCE WTIH FACTORY STANDARDS. 2.7 CLEANING AND PROTECTION OF SLATWALL, ETC. A. CAREFULLY REVIEW PLANS AND DETERMINE LINES TO BE REMOVED AND THOSETO BE KEPT ACTIVE OR TO BE REACTIVATED. A " M A. LEAVE FINISHED INSTALLATION FREE OF CRACKED, CHIPPED, BROKEN, UNBONDED OR OTHERWISE DEFECTIVE TILE WORK. _ -� 2. AFTER DAMAGED OR MISSING ITEMS ARE NOTED ON FREIGHT BILL, HAVE CARRIER'S DRIVER ALSO SIGN IT. THIS WILL VERIFY THAT PROTECT LINES TO REMAIN. PROVIDE FOR MINIMUM SERVICE INTERRUPTION OF LINES TO REMAIN. F. NONUSE HARDWARE FOR SMOOTH OPERATION. B. PROTECT ALL FLOOR TILE INSTALLATIONS WITH CLEAN CONSTRUCTION PAPER OR OTHER HEAVY COVERING DURINGCONSTRUCTION PERIOD TO PREVENT STAINING OR DAMAGE. NO FOOT OR WHEEL TRAFFIC PERMITTED ON FLOOR FOR AT BOTH PARTIES AGREE TO THE EXTENT OF DAMAGE OR SHORT ITEMS. B. REMOVE LINES COMPLETELY WHENEVER POSSIBLE. CUT AND CAP OR PLUG TO PREVENT ESCAPE OF GAS, LIQUID, ETC.. BEHIND LEAST THREE (3) DAYS AFTER GROUTING. s.._. 3. THERE ARE TIMES WHEN DAMAGE IS DISCOVERED ONLY UPON UNPACKING THE FREIGHT. IN ORDER TO RECEIVE PAYMENT FROM QO DOOR HARDWARE; FREIGHT COMPANY, WE MUST PROVE THAT THE FREIGHT WAS DELIVERED IN DAMAGED CONDITION. THEREFORE, ALL CARTONS THE BACK OF THE FINISH MATERIAL PART 1 GENERAL 09900 PAINTING: MUST BE INSPECTED FOR SIGNS OF DAMAGE OR ABUSE AND THIS IS TO BE NOTED WITHIN 24 HRS. C. REPAIR, REPLACE, OR MAKE GOOD DAMAGE TO EXISTING CONSTRUCTION WHICH OCCURS ASA RESULT OF DEMOLITION A FURNISH & INSTALL FINISH HARDWARE FOR INTERIOR & EXTERIOR DOORS WHEN CALLED FOR ON PLAN 4. PHONE THE TRAFFIC DEPARTMENT AT LAUREL, BLAIR BUCHANAN ($56) 461-6600 EXT. 306, AND ADVISE EXTENT OF DAMAGE OR OPERATIONS, AT NO ADDMONAL COST TO OWNER, THE ARCHITECT OF RECORD, OR THE LANDLORD. THESE REPAIRS SHALL PROVIDE PAINTING AS SHOWN OR SPECIFIED. THE TERM 'PAINT' INCLUDES ALL OPAQUE OR NATURAL, PRIME, INTERMEDIATE OR SHORTNESS AND TO RECEIVE DISPOSmON INSTRUCTIONS. INCLUDE ANY ROOF PATCHING REQUIRED DUE TO DEMOLITION AND SHALL BE COORDINATED WITH LANDLORD AND LANDLORD'S B. SEE DOOR SCHEDULE FOR SPECIFIC ITEMS, MANUFACTURERS AND MODEL NUMBERS. TEMPLATES SHALL BE FURNISHED FOR FINISH COATS OF FIELD APPLIED COATINGS. APPLY PAINT IN ACCORDANCE WITH MANUFACTURER'S DIRECTIONS. USE APPLICATORS 5. BE SURE TO CONTACT THE PROJECT MANAGER WITHIN 24 HRS. TO INFORM HIM/HER OF THE LOSS SO THAT, IF NECESSARY, ROOFING CONTRACTOR. USE IN FIELD. AND TECHNIQUES BEST SUITED FOR SUBSTRATE AND TYPE OF MATERIAL BEING APPLIED. PROVIDE TOP-OF-THE-LINE PAINT .s........_______ THE fTEM(S) CAN BE REORDERED. PRODUCTS MANUFACTURED BY ONE OF THE FOLLOWING MANUFACTURERS: ALL DESCRIPTIONS BASED ON SHERWIN-WILLIAMS: 1 , 0301 Q 01122:1E; _,_.._a..................._.. -...-...3.._....._ WHEN THE CONCRETE FLOOR SLAB IS EXISTING, PREPARE THE SLAB TO RECEIVE FINISH AS INDICATED ON THE PLANS. WHEN ON A C. FOLLOW DHI (DOOR AND HARDWARE INSTITUTE) STANDARDS & GUIDELINES AND AWI (AMERICAN WOODWORKING BENJAMIN MOORE, PPG INDUSTRIES, M PROTECTION OF MATERIALS / FURNITURE ON SIVE: GROUND FLOOR LOCATION, THE CONCRETE SLAB FLOOR SHALL BE SEALED IN THE AREAS TO RECEIVE CARPETING. WHEN SLAB FLOOR INSTITUTE) STANDARDS FOR HARDWARE INSTALLED ON WOOD DOORS. SHERWIN-WILLIAMS, PRATT & LAMBERT, GLIDDEN, 15G.C. IS RESPONSIBLE FOR THE SECURITY, CARE AND DAMAGE PREVENTION OF ALL MATERIALS AFTER DELIVERY TO JOB SITE. G.C. WILL IS TO BE EXECUTED AS PART OF THE CONTRACT, FOLLOW LANDLORD'S DIRECTIONS AND SPECIFICATIONS. NAPCO, BUTS D. FURNISH OWNER WITH MAINTENANCE DATA, MAINTENANCE PROCEDURES, MANUFACTURERS WARRANTIES AND SPECIAL TOOLS. BE BACKCHARGED FOR DAMAGES AND MISSING ITEMS. 03015 FLOOR SLAB MODIFICATIONS; PROVIDE SUITABLE COVERING TO PROTECT WORK, THE WORK OF OTHERS AND ADJACENT SURFACES AND OBJECTS. REMOVE OR M_ E. FINISHES: PER HARDWARE SCHEDULE PROTECT SUCH ITEMS AS HARDWARE, ACCESSORIES, PLATES, LIGHT FIXTURES AND SIMILAR ITEMS PLACED PRIOR TO PAINTING. 01500 EXISTING CONDITIONS; GENERAL CONTRACTOR SHALL INSPECT THE EXISTING SLAB CONDITIONS TO DETERMINE THE AMOUNT OF CONCRETE FLOOR SLAB TO BE REPOSITION OR REMOVE PROTECTION UPON COMPLETION OF EACH SPACE. REMOVED AND REPLACED FOR INSTALLATION OF ELECTRICAL, MECHANICAL AND PLUMBING WORK AND STEEL COLUMNS FOR GRILLE GENERAL CONTRACTOR IS TO VISIT THE JOB SITE TO INSPECT THE EXISTING CONDITIONS AND TO VERIFY THE AMOUNT OF WORK THAT - -- - SUPPORT. ALL CONCRETE TRENCHING AND REFILLING, AS WELL AS ANY AND ALL PENETRATIONS OF THE 51A8, SHALL BE EXECUTED IN UM DRYWALL SYSTEMS; PREPARE SURFACES TO RECEIVE PAINT: THOROUGHLY CLEAN OFF GRIME, GREASE, DIRT, CHAD!(, DUST, LOOSE MATERIAL AND OTHER WILL BE NECESSARY FOR THE PROJECT TO BE COMPLETED ACCORDING TO THE CONSTRUCTION DOCUMENTS. ACCORDANCE WITH THE LANDLORD'S REQUIREMENTS. SUBSTANCES THAT MAY INTERFERE WITH PROPER ADHESION OF PAINT. PAINT DRY SURFACE ONLY. SAND LIGHTLY BETWEEN EACH 1 ! PROVIDE ALL GYPSUM DRYWALL MATERIALS THROUGHOUT THE WORK PRODUCED BY ONE MANUFACTURER. PROVIDE METAL STUDS SUCCEEDING COAT OF PAINT. : EXAMINE THE SUBSTRATES AND ADJOINING CONSTRUCTION, AND THE CONDITIONS UNDER WHICH THE WORK IS TO BE PERFORMED. DO Q5Q1Q STRUCTURAL METS; AND FRAMING MEMBERS OF TYPES, GAUGES, SIZES AND CORROSIVE RESISTIVE TREATMENTS AS SHOWN. gqi- NOT PROCEED WITH THE WORK UNTIL UNSATISFACTORY CONDITIONS DETRIMENTAL TO THE PROPER AND TIMELY COMPLETION OF THE THE DESIGN, FABRICATION AND INSTALLATION OF ALL MISCELLANEOUS METAL LINTELS, SUPPORTS AND FRAMING REQUIRED FOR ALL FILL DENTS, CRACKS, HOLLOW PLACES, OPEN JOINTS AND OTHER IRREGULARITIES WITH AN APPROVED FILLER SUITABLE FOR THE WORK HAVE BEEN CORRECTED. STORE FRONT WORK SHALL BE THE SOLE RESPONSIBILITY OF THE TENANT'S GENERAL CONTRACTOR. STUDS AND FRAMING: ROLL FORMED CHANNEL STUDS AND RUNNERS: ASTM C-645, FABRICATED OF PURPOSE. AFTER SETTING, SAND TO A SMOOTH, HARD FINISH. , 06100 ROUGH CARPENTRY; GALVANIZED STEEL PER ASTM WITH FLANGES NOT LESS THAN 1 1/4" OF THE SIZES AND GAUGES SHOWN. CLEAN OFF ALL PAINT SPLATTER OCCURRING ON ADJACENT WORK. REPAIR OR REPLACE WITH NEW APPROVED MATERIAL ALL ill --- BEFORE PERFORMING ANY WORK OR ORDERING ANY MATERIAL, THE GENERAL CONTRACTOR SHALL VERIFY ALL DIMENSIONS OF ANY SURFACES DEFACED ASA RESULT OF THE WORK OF THIS SECTION AND LEAVE WORK INA CLEAN, ACCEPTABLE CONDITION. CC _ pEXISTING OR NEW WORK AND SHALL BE RESPONSIBLE FOR THEIR ACCURACY. ANY DIFFERENCES FOUND SHALL BE SUBMITTED TO THE ALL WOOD FRAMEWORK, WOOD BLOCKING AND PLYWOOD CONSTRUCTION SHALL BE FIRE RETARDANT TREATED AS REQUIRED BY LOCAL METAL FURRING CHANNELS: HAT SHAPED, al- OWNER FOR CONSIDERATION BEFORE PROCEEDING WITH WORK. CODES AND LANDLORD REQUIREMENTS. BACKER PLATES: 7/8' HIGH, 25 GAUGE GALVANIZED. "Q -20 GAUGE GALVANIZED. DRYWALL: CCi PARTICLE BOARD SHALL BE UL CLASS 1 FIRE-RATED, SANDED AND PREPARED TO RECEIVE PLASTIC LAMINATE OR PAINTED METAL HANGER WIRE: GALVANIZED, SOFT TEMPER STEEL WIRE, SIZED IN ACCORDANCE WITH ASTM C-754. PRIME GYPSUM BOARD SURFACES WITH A LATEX PRIMER AND APPLY TWO (2) COATS OF ACRYLIC LATEX, "REGAL WALL SATIN" (FLAT). �`"` " 0161Q PRODUCT HANDLING; LAMINATE. WOOD FRAMING MEMBERS SHALL BE NO. 1 LIGHT FRAMING DOUGLAS FIR OR NO. 2 OR BETTER YELLOW PINE OF THE DIMENSIONS HANGER ANCHORAGE: PROVIDE CONCRETE INSERTS, CUPS, BOLTS, SCREWS AND OTHER DEVICES APPLICABLE TO THE INDICATED WOODWORK: m C CO DELIVER AND STORE MATERIALS IN SEALED CONTAINERS AND BUNDLES, FULLY IDENTIFIED WITH MANUFACTURER'S NAME, BRAND, TYPE INDICATED ON THE PLANS. METHOD OF STRUCTURAL ANCHORAGE FOR CEILING HANGERS. PRIME WOODWORK SURFACES AND TRIMS WITH A WOOD PRIMER, AND APPLY TWO (2) COATS OF 'REGAL AQUAGLO' SATIN FINISH I 1 N AND GRADE. PROTECT MATERIALS FROM CORROSION AND DAMAGE. STORE IN A DRY VENTILATED SPACE, OFF THE GROUND. PLYWOOD SHALL BE GRADE B-D DOUGLAS FIR, SANDED AND PREPARED YO RECEIVE PLASTIC LAMINATE, METAL LAMINATE OR PAINT. ENAMEL. WHEN TRANSPARENT FINISHES ARE CALLED FOR, USE MULTIPLE COATS TO PRODUCE GLASS-SMOOTH SURFACE FILM OF C3 O ` 1 COORDINATE ALL DELIVERIES WITH THE MALL LANDLORD AND TENANT SUPPLIED MATERIAL VENDORS. PLYWOOD BACKING PANELS FOR MOUNTING ELECTRICAL OR TELEPHONE EQUIPMENT SHOULD BE FIRE RETARDANT TREATED PLYWOOD WITH FURRING ANCHORAGES: 16 GAUGE GALVANIZED WIRE TIES, MANUFACTURERS STANDARD WIRE-TYPE CLIPS, BOLTS, NAILS OR EVEN LUSTER. PROVIDE SATIN FINISH FOR FINAL COAT. 0 Z_ , 0 GRADE DESIGNATION, APA C-D NOT LESS THAN 3/4' THICK. SCREWS, IN ACCORDANCE WITH ASTM C-754. "[ Cr. , i- - GENERAL CONTRACTOR WILL RECEIVE AND UNLOAD ALL FIXTURES FROM THE FIXTURE SUPPLIER, ACCORDING TO THE TERMS AND METAL WORK: Cr] PROVIDE FASTENERS AND ANCHORAGE OF THE TYPE, SIZE, MATERIAL AND FINISH AS RECOMMENDED BY APPLICABLE STANDARDS, " „ a � CONDITIONS IMPOSED BY THE MALL DEVELOPER, I.E. SPECIAL TIMES TO UNLOAD, ETC. FIXTURES TO BE SET BY GENERAL CONTRACTOR. COMPLYING WITH APPLICABLE FEDERAL SPECIFICATIONS FOR NAILS, STAPLES, SCREWS, BOLTS, NUTS, WASHERS AND ANCHORING DEVICES. METAL TO METAL WITHIN THE DRYWALL SYSTEM: 3/8" TYPE S OR 5-12, PAN HEAD, PRIME METAL SURFACES (AC REGISTERS AND DIFFUSER ACCESS PANELS) WITH AN ADEQUATE PRIMER AND APPLY TWO (2) COATS OF PROVIDE BLOCKING AS REQUIRED FOR INSTALLATION OF SHELVING, EQUIPMENT, ACCESSORIES, FIXTURES, AND FINISH HARDWARE OR OTHER ADHESIVES: AS RECOMMENDED BY THE GYPSUM BOARD MANUFACTURER. FLAT LATEX TO MATCH CEILING COLOR. PAINT INTERIOR SURFACES OD. DUCTS WHERE VISIBLE THROUGH REGISTERS OR GRIL I FS ti GENERAL CONTRACTOR WILL NOTIFY TENANT IMMEDIATELY OF ANY MISSING OR DAMAGED ITEMS THAT TENANT SUPPLIES AND GENERALWITH A FLAT, NON SPECULAR BLACK PAINT. OMIT PRIMER ON SURFACES THAT HAVE BEEN SHOP-PRIMED. HEAVY ITEMS ON WALLS. TRS ACCESSORIES: CONTRACTOR INSTALLS. HE WILL OBTAIN AND FILL ALL NECESSARY PAPERWORK REQUIRED IN ORDER TO FACILITATE TENANT IN HIS mm-CO---- , aMETAL ""-- ABILITY TO PROPERLY FILE CLAIM FOR DAMAGES OR LOSSES. REFER TO TENANT SHORTAGE/DAMAGED GOODS POLICY INCLUDED IN BID PROVIDE TRIM ACCESSORIES OF THE SIZES REQUIRED FOR THE DRYWALL APPLICATIONS SHOWN SPECIFIED, FABRICATED FROM PRIME DOOR SSURFACES AND TRIM WITH ENAMEL PRIMER AND APPLY TWO 2 COATS OF SATIN FINISH ENAMEL AS SCHEDULED. CO EL INSTRUCTIONS FROM TENANT, 11.510 gRCH�OTSIRAL W90DWQ�(, GALVANIZED STEEL, & OF THE FOLLOWING TYPE: PROVIDE DRYWALL MOULDING OF THE TYPE AND SIZE INDICATED. PROVIDE METAL ( ) (-3 FINISHED WOODS SHALL BE OF THE TYPE SPECIFIED IN THE PLANS AND SHOULD COMPLY WITH PREMIUM GRADE WORK AS DESCRIBED IN CORNER BEAD AT EXTERNAL CORNERS WITH SMOOTH RIGID NOSE AND PERFORATED AND KNURLED FLANGES, CONCEAL FLANGES 10430 ILLUMINATED SIGNS AND CEILING ELEMENTS;CLEANING/ADJUSTING/MAINTENA�NCE/WARRANTIES; 'ARCHITECTURAL WOODWORK QUALITY STANDARDS' PUBLISHED BY THE ARCHITECTURAL WOODWORD INSTITUTE. WITH AT LEAST 2 COATS OF JOINT COMPOUND FEATHERED OUT APPROXIMATELY 9" ON BOTH SIDES OF THE EXPOSED METAL. EXECUTE PERIODIC CLEANING DURING PROCESS OF WORK, AND AT COMPLETION OF THE WORK, SO THAT ALL FINISHED SURFACES ARE SUPPLIED AND INSTALLED BY TENANT'S SIGN CONTRACTOR. GENERAL CONTRACTOR SHALL COORDINATE INSTALLATION TO ASSURE W FREE OF ANY FOREIGN MATERIAL- CONDUCT CLEANING AND DISPOSAL OPERATIONS TO COMPLY WITH CODES ORDINANCES REGULATIONS, THE WOOD SHALL BE STRAIGHT AND FREE OF BLEMISHES AND OF SUFFICIENT LENGTH TO PERMIT A MINIMUM NUMBER OF JOINTS. WHERE DRYWALL ABUTS OR INTERSECTS DISSIMILAR CONSTRUCTION, PROVIDE SQUARE EDGE SEMI-FINISHING CASING BIND (NO PROPER COMPLIANCE WITH CONSTRUCTION DOCUMENTS AND LANDLORD CRITERIA ANTI-POLLUTION LAWS AND LANDLORD REQUIREMENTS. REMOVE GREASE, MASTIC, ADHESIVES, DIRT, STAINS, LABELS AND OTHER CONDITION WOODWORK TO PREVAILING HUMIDITY CONDITIONS IN INSTALLATION AREAS PRIOR TO INSTALLING. JOINT COMPOUND TREATMENT NECESSARY). CO FOREIGN MATERIALS FROM SIGHT EXPOSED SURFACES. GENERAL CONTRACTOR SHALL REMOVE ALL CONSTRUCTION DEBRIS FROM i 0440 INTERIOR SIGNAGE: TAPE AND JOINT MATERIAL SHALL BE APPLIED TO THE JOINTS. THE JOINT COMPOUND SHALL BE SMOOTHED OUT APPROXIMATLEY JOBSITE, ON A DAILY BASIS. INSTALL WOODWORK PLUMB, LEVEL, TRUE AND STRAIGHT WITH NO DISTORTIONS. SHIM AS REQUIRED USING CONCEALED SHIMS. INSTALL TO 4" WIDE. THIS IS TO BE IN THE NORMAL THREE-COAT PROCESS, ALLOWING 24 HOURS DRYING TIME BETWEEN COATS. ALL AWLS, SUPPLIED AND INSTALLED BY GENERAL CONTRACTOR AS PER MANUFACTURER'S INSTRUCTIONS. REFER TO DRAWINGS FOR TYPE AND A TOLERANCE OF 1/8' IN 8'-O' FOR PLUMB & LEVEL & WI NO VARIATIONS IN FLUSHNESS OF ADJOINING SURFACES. ANCHOR LOCATION. SCREWS, HEADS OR DIMPLES SHALL ALSO RECEIVE A THREE-COAT FINISH USING THE SAME MATERIAL AND MANNER NAILS, SCREWS, �"�` PROTECT D MAINTAIN ALL WORK THROUGHOUT CONSTRUCTION SO THAT IT WILL BE FREE OF DAMAGE AT THE TIME OF ACCEPTANCE WOODWORK TO ANCHORS, OR BLOCKING BUILT-IN, OR DIRECTLY ATTACHED TO SUBSTRATE. SECURE W/ CONCEALED FASTENERS. HEADS OR DIMPLES SHALL ALSO RECEIVE A THREE-COAT FINISH USING THE SAME MATERIAL AND MANNER AS THAT FOR AS THAT DIVISION 011000 - EQUIPMENT; v a FOR THE JOINTS. SAND SMOOTH ALL JOINTS AND SURFACES AND HAVE THEM READY TO RECEIVE THE WALL FINISH. VERIFY SAND ff f BY THE TENANT. 011001 - EQUIPMENT a U COMPLETION: ALL SURFACES SHALL BE SANDED TO A SMOOTH SURFACE, READY FOR STAINING OR FINISH PAINTING AS PER DETAILS AND SCHEDULES. SMOOTH ALL JOINTS AND SURFACES AND HAVE THEM READY TO RECEIVE THE WALL FINISH. VERIFY THAT THE EXISTING WALL THAT c, STORE TO BE READY FOR OCCUPANCY - ALL SURFACES CLEAN. THE EXISTING WALL SURFACES, IF ANY, ARE SMOOTH AND SUITABLE, AS A SUBSTRATE FOR THE FINISHES SCHEDULED. PARE 1 - GENERAL d Li- C.) 01700 01700 CANING ADJUSTING MAINTENANCE ARRANTIES; 06410 HARDWARE; GYPSUM BOARD: A. CONTRACTOR SHALL COORDINATE ALL EQUIPMENT WORK AND PLACEMENT WITH THE WORK OF ALL OTHER TRADES AND MAKE PART 1 - GENERAL , / HARDWARE SHALL BE OF THE TYPE, FINISH AND MANUFACTURER SHOWN. MANUFACTURER'S CATALOG NUMBERS USED HEREIN ARE 5/8' THICK UNLESS NOTED OTHERWISE. ADJUSTMENTS AS REQUIRED TO ACCOMMODATE LOCATIONS OF EQUIPMENT. w INTENDED TO INDICATE THE QUALITY REQUIRED. ALTERNATE MANUFACTURERS AND PRODUCTS MAY BE SUBMITTED TO THE TENANT FOR B. ALT. EQUIPMENT WORK SHALL COMPLY WITH ALL GOVERNING BUILDING CODES AND LOCAL CODES. a- t A. FINAL CLEANING1. GENERAL CONTRACTOR TO PROVIDE A PROFESSIONAL CLEANING SERVICE TO EXECUTE [-ANAL CLEANING PRIOR TO SUBSTITUTION APPROVAL. NO OTHERS SHALL BE ACCEPTABLE. ASTM C36, TAPERED EDGES. PROVIDE 'TYPE X" (FIRE RETARDANT) WHERE SHOWN AND AT DEMISING WALLS. - -� �-- CO B. ADJUSTING C. EQUIPMENT SHALL BE FURNISHED, UNLOADED, UNPACKED OR UNCRATED AND PLACED ACCORDING TO THE CONSTRUCTION 1. ADJUST OPERATING PRODUCTS AND EQUIPMENT TO ENSURE TURN-OVER. FURNISH HARDWARE TEMPLATES IN A TIMELY MANNER TO THE VARIOUS AFFECTED TRADES FOR COORDINATION OF THEIR WORK. WATER RESISTANT GYPSUM BOARD (GREENBOAIZD) ASTM C-630 TYPE "W". PROVIDE FOR WET WALLS IN TOILETS. USE "DURLOCK" DOCUMENTS. k, Q C. OPERATION AND MAINTENANCE DATABEHIND ALL CERAMIC TILE AND MARBLE ON WALLS. W 1. SUBMIT DATA BOUND IN 8-1/2x11 INCH TEXT PAGES, THREE D PRODUCTS IN QUANTITIES SPECIFIED IN INDIVIDUAL SEALANT: p 1 _ P �� CC SPECIFICATION SECTIONS. NW 1 - GEIER L A. ALL EQUIPMENT PROVIDED BY OWNER AND INSTALLED BY GENERAL CONTRACTOR IS TO BE INCLUDED IN GENERAL BID. A. FURNISH AND INSTALL ALL GYPSUM DRYWALL AND SYSTEMS COMPLETE WITH PARTITION FRAMING, CEILING SUSPENSION 2. PREPARE BINDER COVER WITH PRINTED TITLE "OPERATION & MAINTENANCE INSTRUCTIONS', TITLE OF PROJECT. SIDE RING A. EXPANSION JOINT MATERIAL, SEALANTS AND JOINT BACKING FOR SYSTEMS AND RELATED ACCESSORIES, PARTS, MATERIALS, ETC. AS SHOWN ON DRAWINGS AND AS SPECIFIED. INSTALL ALL B. GENERAL CONTRACTOR SHALL NOTIFY THE OWNER IMMEDIATELY OF ANY DAMAGE TO THE EQUIPMENT PRIOR TO cc !:7; BINDER W/ DURABLE PLASTIC COVERS. JOINTS BETWEEN DISSIMILAR MATERIALS. MATERIALS PER MANUFACTURERS SPECIFICATIONS AND RECOMMENDATIONS. INSTALLATION. o w 1. SILICONE SEALANTS (TYPE 5): ASTM C920, SINGLE COMPONENT, NON SAGGING, NON-STAINING, NON-BLEEDING; FOR C. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL FINAL HOOKUP OF ALL EQUIPMENT SUCH AS ALL MECHANICAL cn Q 0 co PART 2 - PREPARATION / EXECUTION; USE AS GENERAL CAULKING; COLOR TO MATCH ADJACENT SURFACES, MANUFACTURER BY GE SILICONES OR EQUAL B. GYPSUM DRYWALL.: ALL GYPSUM BOARD TO BE 5/8' TYPE 'X' AS NOTED ON SHEET A1.0 (CONSTRUCTION PLAN). WORK, PLUMBING, & ELECTRICAL FOR THE EQUIPMENT LIST. ' T = A. FINAL CLEANING RESTROOMS TO RECEIVE MOISTURE RESISTANT GYPSUM BOARD. m 1. CLEAN INTERIOR AND EXTERIOR GLASS, SURFACES EXPOSED TO VIEW; REMOVE TEMPORARY LABELS, STAINS & FOREIGN 2. JOINT BACKING: ROUND, OPEN CELL POLYETHYLENE FOAM ROD. D. ALL EQUIPMENT MANUALS INSTRUCTION BOOKLETS & WARRANTY INFORMATION SHALL BE NEATLY BOUND & TURNED OVER rCI: U SUBSTANCES, POLISH TRANSPARENT AND GLOSSY SURFACES, VACUUM CARPETED AND SOFT SURFACES. 2. C. FASTENERS: DRYWALL SCREWS OF PROPER SIZE AND TYPE PER MANUFACTURERS RECOMMENDATIONS. TO THE OWNER BEFORE SINAL APPROVAL OF THE BUILDING. MATERIAL BEING CLEANED.UIPMENT AND FIXTURES TO A SANITARY CONDITION WITH CLEANING MATERIALS APPROPRIATE TO THE SURFACE AND D. PROVIDE MATERIALS, JOINT COMPOUNDS, TRIM, EDGES, BEADS, ETC. FROM A SINGLE SOURCE SUPPLIER. ALL TRIM SHALL END OF DIVISION o `a' - Q 3. REMOVE WASTE & SURPLUS MATERIALS, RUBBISH & CONSTRUCTION FACILITIES FROM THE SITE. CONSIST OF A TAPERED, GROOVED, AND PREPUNCHED FIN FOR SCREW ATTACHMENT AND TO ACCEPT BONDING AGENT. ALL BUTT JOINTS ARE TO BE NEAT WITH TIGHT JOINTS, AND ALL CORNERS ARE TO BE MITERED. ALL EDGES, BEADS AND TRIM T1.0 TO BE PRE-FINISH ALUMINUM. H FINISH SCHEDULE VENDOR SCHEDULE RESPONSIBILITY SCHEDULE RESPONSIBILITY SCHEDULE 3 , . PAK COMPANY CONTACT PHONE NUMBER FAX NUMBER EMAIL ADDRESS !� -tris ` ITEM FURNISHED INSTALLED EXIST. REMARKS ITEM FURNISHED INSTALLED EXIST. REMARKS T IO W al SATIN LATEX FLAME SPREAD CLASS 1/A "� ANCHOR SIGN MATTHEW BRIGGS (843) 576-3294 (843) 576-7294 mbriggs@anchorsign.com RESPONSIBILITY SCHEDULE IS GENERAL IN Z RESPONSIBILITY SCHEDULE IS GENERAL IN 4 �' W: -- 4 DOORS AND TRIM: SEMI-GLOSS ALKYD FUME SPREAD CLASS 1/A Z - • c7 0 '-'-' o NATURE AND DOES NOT REFLECT EVERY c o 'y' o NATURE AND DOES NOT REFLECT EVERY 1 �- 1. ..I . • S ]LI CdS: FLAT LATEX FUME SPREAD CLASS 1/A BOSTON BARRICADE MICHELLE BOUCHARD (772) 257-7336 (772) 257-7329 mbouchardObostonbarricade.com D ; l�# �' c c) c c- Q COMPONENT OR RESPONSIBILITY. U.O.N. a' c� ix c) Q COMPONENT OR RESPONSIBILITY. U.O.N. I O INSTALLATION: GYPSUM BOARD TO RECEIVE LATEX PAINT TO BE PRIMED WITH (1 COAT OF VINYL PLASTIC z z RESPONSIBILITY IS G.C. FURNISHED AND z = RESPONSIBILITY fS G.C. FURNISHED AND z • +ipti. LAUREL BLAIR BUCHANAN (856) 461-6600 EXT. 306 (856) 461-6622 blair.bOlaurefmfg.com o o v Jo 5 r o Z c..) J A.SEALER PRIOR TO RECEIVING (2) COATS OF PAINT. WOOD TRIM AND SLATWALL 0 RECEIVE ALKYD OR z o z zo O a INSTALLED. z ,,, o Z o o a INSTALLED. >Fr i W hI ENAMEL PAINT TO BE PRIMED W./ ONE COAT OF ENAMEL UNDERCOATER PRIOR TO RECEIVING (2) COATS OF MIDWEST LIGHTING ANO GULASARIAN (323) 957-6031 (323) 462-2108 anoOmidwestlighting.com c� c� z cn v v z cn �► N� Nm i PAINT. PAINT ALL WIRES, RETURN AIR GRILLE, & SUPPLY AIR GRILLE TO MATCH ADJACENT CEILJNNG AREAS. EMOBILE MEDIA LINDA LUONGO (800) 784-8080 Ih@mobilemediastorage.com SEIM i •AN P-1 BENJAMIN MOORE #PM-8 "CHARCOAL SLATE" LCD SIGN & BRACKET • • NEUTRAL PIERS • VERIFY DETAILS WITH LANDLORD ONSITE MEDIA SOLUTION FORD HOOK (435) 214-0293 fordOonsitemedia.com r !. IL • P-2 BENJAMIN MOORE #PM-1 "SUPER WHITE" PROJECTION & BRACKETS • • CONTINUOUS REVEALS • • 3/4" BLACK METAL REVEAL _ .• .- MOOD MEDIA MARISSA JONES (512) 380-8547 marissa.jonesOmoodmedia.com p-3 BENJAMIN MOORE #PM-9 "BLACK" REAR DOOR SIGNAGE • a STOREFRONT FRAMING a • SEE SHEET A5.0 ...M... 4k_.- WG SECURITY BRYAN LINSKY (714) 730-8049 (714) 389-5785 blinskyOwgspi.com VINYL WINDOW GRAPHICS • • PR. ENTRY DRS/ HARDWARE • • 0 p ' BENJAMIN MOORE 2022-30 "BRIGHT YELLOW" P42-84; P42-3B > P-4 SUPER SPEC HP WATERBORNE POLYAMIDE EPDXY HIGH SHOPPER TRAK ANDREW FOLEY (312) 529-5316 ofoleyOshoppertrak.com BARRICADE GRAPHICS a • FLOORING / Oa L T C L T C NS a - _ SPACEWALL TERRY SEXTON (714) 961-1300 (714) 961-0976 tsextonOspacewallwest.com CODE-RELATED SIGNAGE • • PER INSPECTOR'S REQUIREMENTS I-LOW CURING C NC. • • G.C. TO COORD. W/ OWNERS VENDOR � �t AT ANY DOOR INFILL/PATCH XT G. Q d ." IN THE EVENT THAT G.C. IS DIRECTED TO OVERLAY DOM FLOOR, NEW FLOORING SHALL HAVE A KEVIN PARTIN (858) 253-1612 kevin.partinOdiamaticusa-com SIGN PERMIT & APPL, • • WHEN REQUIRED CONCRETE SEALER • • MATTE FINISH - STOCK / HALL SMOOTH TROWEL FINISH*" DIAMATIC FLOORS JOE REARDON (619) 295-0893 joe.reardonOdiamaticusa.com EXISTING SIGNAGE REMOVAL • • WHEN REQUIRED SHT. VINYL 0 TOILET RM. • • 0 w g SURFACE PREPARATION TOILET �y L T C L T C N S FLOOR TRANSITIONS ! • N. REMOVE ANY FLOORING MATERIAL THAT MAY EXIST. ARCHITECTURAL GLASS RON HOLMES (479) 685-5571 ronholmeslOme.com 1 1. IF REMOVAL OF GLUE, PAINT, THIN-SET OR ANY OTHER COATING WATER CLOSET • • • G.C. TO REPLACE OR REPAIR AS REQUIRED- VINYL BASE • • NON-PUBLIC AREAS ONLY T _-••-• 2. PATCH ALL HOLES AND CRACKS. ORORA VISUAL RICHARD DE LA ROSA (323) 551-6586 (626) 484-1498 nchard.delarosaOororavisudcom I 3. DIAMOND GRIND AND OR SAND CONCRETE AS NEEDED TO A SMOOTH AND LEVEL SLAB BEFORE APPLYING STAIN. WORLDLINK BRETT BUSCONI (949) 861-2830 EXT. 229 constructionOworldlinkintegration.com LAVATORY • • ! G.C. TO REPLACE OR REPAIR AS REQUIRED. MDF BASE • • G.C. TO SCRIBE TO FLOOR. ' ' ,. N MALL FLOORING AT ENTRY • • G.C. TO COORDINATE W/ MALL OPS MGR. O FLOOR INSTALL PRIVEE DESIGNS NICK FREDRICKSON (714) 922-1400 nfredricksonOalliedmodular.com .���i N. �� CS-1 STAINWOO ++���• +r ►��1� , :: ..r y .y. SALES FLOOR FLOORING • • - LL • " PALATINE *PREFERRED ., �����b, .. � � � i7'[7 ' 7 4 LD • BEHR WHITE BASE #800 CONCRETE STAIN - CUSTOM COLOR: CHARCOAL SLATE ORDER # IAN MACK (847) 952-1400 imackOplatinebuilderssupply.com S LT C L T C NS I. - 665717386712 IN SALES AREA, ALCOVE AND FITTING ROOM. VENDOR ONLY* TOILET PAPER DISPENSER • • • G.C. TO REPLACE OR REPAIR AS REQUIRED. I�I. • GC TO LAY DOWN BEHR PREMUM (#88001) CONCRETE & MASONRY BONDING PRIMER PAPER TOWEL DISPENSER • ! • G.C. TO REPLACE OR REPAIR AS REQUIRED. DEMISING PART. STUDS a • 0 v. • PRIOR TO STAIN. IDOOR SCHEDULE - DEMISING PART. DRYWALL • • • PATCH, REPAIR, & REPLACE AS REQUIRED SEALER GRAB BARS • • • G.C. TO REPLACE OR REPAIR AS REQUIRED. r.. O1 cm • BEHR PREMIUM CONCRETE BRICK & TILE LOW LUSTER SEALER KEY DESCRIPTION NILW WALL FRAMING/ • • t», GC TO NOTE SOLVENT BASED SEALER'S ARE NOT ALLOWED MIRROR(S) • • • G.C. TO REPLACE OR REPAIR AS REQUIRED. BLOCKING �' GC TO APPLY TWO (2) COATS OF CHARCOAL SLATE STAIN AND ONE (1) COAT OF SEALER ON I MARLITE PANELS/J-MOLDING • • _TOILET OOL KING/hMPFKRAAAMMMING/ • • • PATCH, REPAIR, & REPLACE AS REQUIRED Ili _ g -1-- A A SMOOTH AND LEVEL SLAB. FURRING AROUND CLRNT AXL BL FL BACKING FOR ALL ITEMS BASE: 800 EXISTING TO REMAIN - REPAIR TO "LIKE NEW" CONDITION. REPLACE, IF REQUIRED FOR NEW DOOR PULLS. • • • • a PATCH, REPAIR, & REPLACE AS REQUIRED LISTED ABOVE AS REQ. ___GOLUMN5 AT DEMISECC + ' S/CLR CONCRETE STAIN/SINN - SOLID COLOR 0R1 NT 4 0 TRASH CAN • • INTERIOR COLUMN FURRING • • Q W t [CF} (3086 21/014) CT7 CHARCOAL SLATE 384th 271 337 127 HARDWARE: z Z "" " """" m -----T--- G.C. G.C. TO PROVIDE NEW "BEST" 7 PIN CYLINDER CORE SOAP DISPENSER • • BLOCKING FOR DOORS a a PREPARE FLOOR SAME AS MAIN FLOOR. - ._... CS-2 • BEHR PREMIUM CONCRETE BRICK & TILE LOW LUSTER SEALER G.C. TO PROVIDE NEW DOOR PULLS (FINISH: MATTE BLACK) - REUSE EXISTING MOUNT LOCATIONS IF POSSIBLE- N.E.E. LT C L T C NS WALL PREP. AND FAINT • • GC TO NOTE SOLVENT BASED SEALER'S ARE NOT ALLOWED CORNER GUARDS • • G.C. TO CUT DOWN IN FIELD AS NEEDED _. _ GC TO APPLY ONE (1) COAT OF SEALER ON A SMOOTH AND LEVEL SLAB. G.C. TO SUBMIT SHOP DRAWINGS FOR DOOR HARDWARE TO BOX LUNCH P.M. FOR APPROVAL PRIOR TO ORDERING. LT C LTC NS ARMSTRONG CONNECTION, TILE VINYL FLOORING, CORLON #88724 "PORCELAIN' GYP. BD, CEILINGS • • VF-1 HEAT WELDED SEAMS & 6" COVED SELF BASE -�iNATI EXPOSED DECK r ROOVIDDE E� MFGR'S RECOMMENDED ADHESIVE. FLAME SPREAD CLASS 1/A PR - SIGN ABOVE DOOR IN 1" HIGH LETTERS ON A CONTRASTING BACKGROUND STATING 'THIS DOOR • • AT PUBLIC AREAS DALTILE MATCHPOINT COLORBODY P124 JET BLACK UNPOLJSHED 1' X 2' BLACK MATTE TILE WITH BLACK TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED" WHEN REQUIRED BY CODE DEMO/PREP OF EXPOSED , - T-1 GROUT - SUPPLIED BY G.C. VERIFY SPEC. W/ OWNER PRIOR TO INSTALL. DECK READY TO PANT • 5 I SUSPENDED ACT CEILING • a WHEN REQUIRED _. s BANSE El SALES AREA TO HA LMIAY/HN.LWAY TO STOCKROOM Dom, INXES LT C LTC NS & 0 NEW 0 EXISTING - PROVIDE AS NOTED BELOW IF EXISTING IS UNSUITABLE. B-1 4 1/2" HIGH MDF BASE, PAINTED P--1 DOOR: /HAHA/HARDWARE FITTING ROOM FRAME • • AREA APPLIED: WALL BASE THROUGHOUT STORE 3'-O" x 7'-0" x 1-3/4" SOLID CORE WOOD DOOR. PAINT PER INT. ELV. G.C. TO SPRAY DOOR BLACK - DO NOT USE ROLLER I ALCOVEQ &qq ST --CC�K ppROOM • • m--"-� NOTE: SEE SHEET A7.0 FOR INSTALLATION DETAIL : ', TOIL ctE4/WARE MAINTAIN FINISH PER MANUFACTURER'S RECOMMENDATIONS 3'-O" X 7'-O" 18 GA. CURRIES K/D STEEL DRYWALL FRAME EMBOSSED FOR 1-1/2 PR. BUTTS. • • COLOR: FACTORY FINISHED BLACK. NOTE: FRAME USES PRE-THREADED SCREWS. DOOR USES WOOD SCREWS. / FRAME/HARDWARE 4' B-2 ARMSTRONG # V4860, JET BLACK, 4" VINYL COVED BASE G.C. TO PROVIDE AS NEEDED. ,% REAR DOOR AND FRAME • , g AREA APPLIED: IN STOCKROOM / HALLWAY ONLY FLAME SPREAD CLASS 1/P HI ]REA�JRN DOOR CyPANIC ERAR/ a a • G.C. TO REPLACE OR REPAIR AS REQUIRED. 3 1-1 2 PAIR PB-RC-RP 4" x 4" BLACK (3/BOX) 345 kEY ALL U cdaiKE A LIES LASE LATCHES: / O TURNOV,R I • SCHLAG , ND1OS PASSAGE LOCK, MATTE BLACK \ ACCESS PANELS AS REVD CG--1 CORNER GUARDS - 1"xl"x12'-O" HIGH BLACK METAL CORNERGUARD (#110165-023 FLAT BLACK) CLOSER: % FOR MOTORS/VAIN/ETC- • • AS REQUIRED ', INC. (800) 328-2495 G.C. TO MODIFY IN FIELD AS NEEDED PER LCN SERIES 4040 - AL OR APPROVED EQUAL IBQIl1 L T C L T C N S - .*: . MANUFACTURER: STYLMARK, NOTES: SEE MECHANICAL, PLUMBING, AND HOOKS • 5 ............ APPLJCATION -- APPLY W/ HEAVY DUTY ADHESIVE, NO SCREWS OR NAILS TO BE USED. • PROVIDE DOOR BUMPER "QUALITY" NO. 302. (VERIFY W/ PLAN WHEN DOOR SWINGS TO WALL) CG-2 CORNER GUARDS - 3/4" QUARTER ROUND WOOD TRIM. G.C. TO MODIFY IN FIELD AS NEEDED. PANT • PROVIDE 12" x 32" STAINLESS STEEL KICK PLATE. SEE INTERIOR ELEVATIONS ELECTRICAL SHEETS FOR MIRROR • • ink i 411 MATTE BLACK, P-3. G.C. TO USE FINISH NAILS TO INSTALL. � , � ENGINEERING SCHEDULES AND CAULKSf$ILICONES • a AS REQUIRED � �l 5// WC-1 FRP WAINSCOT - MARLITE - COLOR: P-100 WHITE FLAME SPREAD CLASS 3/C 0 NEW 13 EXISTING -- PROVIDE AS NOTED BELOW IF EXISTING IS UNSUITABLE. SPECIFICATIONS MASTIC ADHESIVE BENCH • a - - 3'Olt 3'-00 x 7'-0" x 1 3/4" SOLID CORE, PAINT GRADE WOOD DOOR. PAINT P-2 '.. DOOR 0 0 w_.--, 2IA_AL FRAYE , 3'-0" X 7'-O" 18 GA. CURRIES K/D STEEL DRYWALL FRAME EMBOSSED FOR 1-1/2 PR. BUTTS. � AREA & FDCTURES LT C L T C NS SW-1 "SPACEWALL" OSB PANEL W/ METAL REINFORCED SLATS 0 3" O.C. - FINISH BY MANUFACTURER (MATTE \ FREESTANDING FLOOR ..........M . COLOR: FACTORY 'NAVAJO WHITE' • • G.C. TO ASSEMBLE AS REQUIRED WHITE W/ WHITE INSERTS.) SEE DETAILS ON SHEET A7.0 HINGES: FIXTURES 1 I SW-2 "SPACEWALL' PAINT GRADE MDF PANEL SLATWALL W/ METAL REINFORCED SLATS 0 3" O.C. FINISH BY 1-1/2 PAIR PB-RC-RP 4" x 4" SATIN CHROME (3/BOX) 345 CASH WRAP/ COUNTERS • • G.C. TO ASSEMBLE AS REQUIREDII 41- MANUFACTURER (MILLENNIUM OAK W/ BLACK INSERTS.) SEE DETAILS ON SHEET A7.0 LOCKS / LATCHES: WALL & DISPLAY FIXTURES a • -- -. '�'' FALCON LEVER TYPE PRIVACY SET. SATIN CHROME W/ CHROME STRIKE. I .CO MISC. SALES WOOD TRIM • • G.C. TO ASSEMBLE AS REQUIRED ILK el* INTERNATIONAL SYMBOL OF ACCESSIBILJTY AS REQUIRED BY CODE 4# W CLOSER SLATWALL _ • a CC41::C wLU i ' NORTON NO. 1603 ALUMINUM DOOR CLOSURE. W/ 90' HOLD OPEN LOOSE HARDWARE AND • • G.C. TO CLEAN AND INSTALL WV MT-1 FLOORING TRANSITION - SCHLUTER SYSTEMS ANODIZED ALUMINUM NOTES: �IVIIV6 HARDWARE ! • �_ . CU £ ";........0 ...-.-- • PROVIDE DOOR BUMPER "QUALITY" NO. 302. (VERIFY W/ PLAN WHEN DOOR SWINGS TO WALL) FIXTURES INTO STORE _ Q co 1 ;� METAL CLADDING - .063 MATTE BLACK POWDERCOATED ALUMINUM. MIN. 18 GA. REQUIRED. UNPACK DISPOSE OF MT-2 G.C. TO PAINT SUBSTRATE UNDERNEATH WITH A MATTE BLACK PAINT FINISH. FLTTNG ROOM POOR: / • • OFFLOAD FROM TRUCK II 1 �4 FIXTURE WRAPPINGS Cy i� ❑ NEW 0 EXISTING - PROVIDE AS NOTED BELOW IF EXISTING IS UNSUITABLE. LT C LT C NS (z 8 ................ DOORCORNER GUARDS a • REQUIREMENTS TO BE DETERMINED IN FIELD Z 1O �• 3'-0" x 5'-O" x 1 3/4" DOOR SUPPLJED BY TENANT & INSTALLED BY G.C. � T. � r TOILET ACCESSORIES FRAME BULLETIN BOARDS AND `� CC I 18 GA. CURRIES KNOCKDOWN DRYWALL FRAME IN BLACK FINISH MISC. ITEMS • • v Q 4: NOTE IF ITEMS ARE MING, REPLACE DAMAGED OR MISSING ITEMS AS SHOWN HERE STRUCTURAL SUPPORT • • - _ � - " HAGER (2) 661279 FULL MORTISE HINGE - 4.5" X 4.5" MATTE •BLACK. & (1) 881250 FULL MORTISE SPRING HINGE, FOR XFMR. IF REQ D. L�.J --..... i AC-1 36" GRAB BAR - BOBRICK #B-6806.99 X 36 - SURFACE MOUNTED. PROVIDE SOLID TOTAL 3 HINGES PER DOOR, BY G.C. TABLE/FILE CABINET a • � ' ._0 ..s. BLOCKING BLOCKING IN WALL - REAR BAR TO EXTEND 12" BEYOND CENTER OF THE WATER LOCKS / LATCHES: uLS[FI1�11F[rii� L T C L T C N S SHELVING HANGING ,�' J i Q CLOSET TOWARD THE SIDE WALL AT LEAST 24" TOWARD THE OPEN SIDE OF THE SUPPLIED BY VENDOR AND INSTALLED BY G.C. / • • INCL. SHELVES, STANDARDS AND BRACKETS # �t3 . WATER CLOSET AND MOUNTED NO MORE THAN 9" BEHIND THE WATER CLOSET SEAT. DOOR STOP: PICK—UP PERMIT �L .com C / BACKING FOR ALL ITEMS �i . OJ �� � �� AC-2 42" GRAB BAR - BOBRICK #B-6806.99 X 42 - SURFACE MOUNTED. NES 407 - 1/2, 108 PAY PERM(' FEE • • LISTED ABOVE • • AS REQUIRED FOR SECURE ATTACHMENT p� (J] CONSTRUCII N TE PROVIDE INFORMATION TO BOX LUNCH AND NOTES: PHONE AND FAX • • • PROVIDE SOLID BLOCKING IN WALL ITECT. *G.C. NOTE; ,,,IL • (8) EXTRA KEYS TO BE FURNISHED FOR OWNER, BY G.C. I J I REAR SEIt1ACE DOOM CONSTRUCTION SITE DE WEEKLY E-MAIL PHOTO'S. AC-3 18" GRAB BAR - BOBRICK #B-5806.99 X 18 SURFACE MOUNTED. DIGITAL CAMERA • • T BOX LUNCH G.C. TO REVIEW BILL OF LADING UPON RECEIPT OF ALL SHIPMENTS. ANY DAMAGES OR 1 1 PROVIDE SOLID BLOCKING IN WALL OBTAIN C O APPROVALS SHORTAGES ARE TO BE INDICATED AT RECEIPT, OR WITHIN 24 HOURS. FAILURE TO DO """_""" ""- IN WRITI t A.W.A. • TOILET PAPER DISPENSER - CENTERED O 19" A.F.F., MIN. - SURFACE MOUNTED. El NEW ❑ NOT USED ® EXISTING - PROVIDE AS NOTED BELOW IF EXISTING IS UNSUITABLE. SO WILL REQUIRE G.C. TO CONTACT VENDORS LISTED ABOVE AND PURCHASE SAID - AC-4 SPRINK SYS. PLANS/ CHANGE ORDERS NO PROCESSED WIIHOU1 = GEORGIA-PACIFIC: SOFPUL CENTERPULL DISPENSER - MFG. PART #56501 COLOR: SMOKE p0011: " PLANS/ PERMIT/ FEES • • A.W.A. #'S. ITEMS AT G.C. COST. € £ GEORGIA-PACIFIC: SOFPUL CENTERPULL ADA NOZZLE - MFG. PART #56505 31-0 x 7'-0' METAL DOOR AND FRAME. MODIFY SPRINKLER SYS. • • VERIFY MALL'S REQUIRED CONTRACTOR CO WALL MOUNTED 18"X36" MIRROR - WITH BOTTOM OF REFLECTIVE SURFACE AT LOCKS / LATCHES: MALL DEPOSII z ! W AC-5 +40" A.F.F. BOBRICK #290 1836 - SURFACE MOUNTED. NEW DETEX V4OXEB PANIC / ALARM HARDWARE W/ 7-PIN MORTICE CYLINDER & SATIN CHROME STRIKE. l •SURANC S • J (ALWAYS PROVIDE THIS UNLESS SUITABLE EXISTS) G.C. TO INSTALL PRY PLATE AT EXTERIOR, NO HANDLE ALLOWED. JANITORIAL S VIE TWO CLEANINGS: FIRST AT PUNCHLIST r { AC-7 TOILET SEAT COVER DISPENSER - BRIGHTON PROFESSIONAL - SIGNAGE: FINAL •CLING • SECOND CLEANING DAY PRIOR TO OPENING. Q MFG. ITEM #BPR24778 - COLOR: WHITE LABEL MALL SIDE WITH TENANT'S NAME AND SPACE NO. PER LANDLORD'S REQUIREMENTS TRASH REMOVAL/ a CLOSER DUMPSER RENTAL • LLI AC-8 WALL MOUNTED WATER HEATER BELOW LAVATORY - SEE PLUMBING SHEET NORTON #1603 SINGLE DOOR KEEPER OR EQ. ROOF PENETRATIONS • • VERIFY MALL'S REQUIRED CONTRACTOR I AC-9 SIGN WITH RAISED BRAILLE LETTERS - MOUNTED AT +60 A.F.F. IVES 698 190 deg. DOOR VIEWER. DEMOLITION PERMIT AND • V FEES AS R (�UIREQ AC-10 PLASTIC TRIM AT +48" A.F.F. AT MAR LITE WAINSCOTEE INV NOTES: OBTAIN INS CTIO S �--� � � •TENANT'S G.C. SHALL MAINTAIN TIGHT FITTING SMOKE AND DRAFT CONTROL ASSEMBLY HAVING A FIRE RATING OF NOT LESS PROVIDE STATUS REP OBT • _ I I 1 1 AC-11 AUTOMATED ROLL TOWEL DISPENSER - GEORGIA-PACIFIC: SOFPUL AUTOMATED THAN 90 MIN- WHEN TESTED. INSTALL GASKET MATERIAL AS TO PROVIDE A SEAL WHERE DOOR MEETS THE STOP ON ALL SIDES. PROVIDE AS-BUILT COPY • ' DISPENSER - MFG. PART #59010 COLOR: BLACK •PANT MAL SIDE OF DOOR AND FRAME TO MATCH ADJACENT MALL'S FINISH OR AS DIRECTED BY THE RECEIVE.? NL ALL I ICC MALL'S ON-SITE REPRESENTATIVE. WHEN THE SPACE IS OCCUPIED. J�J�q ��p �p • AC-12 SOAP DISPENSER - BRIGHTON PROFESSIONAL (BOOmL) - MFG. ITEM #26463 SOE3 NTO4IPPLURAC(UR ITEMSTST "' 'm „" " `""'" COLOR: BLACK • PROVIDE TO OWNER AT TURNOVER I DOOR NOTES AND WARRANTIES .__ 1I J �. ..--. .. . . , U TEMPORARY BARRICADE • • COORDINATE WITH LANDLORD AND MALL. o o EXIT DOORS SHALL BE OPERABLE FROM WITHIN WITHOUT USE OF ANY SPECIAL KNOWLEDGE OR EFFORT WHEN THE SPACE IS OCCUPIED. u.c. PKUJtU1 MGK. Silt o m *' ABBREVIATIONS a MAXIMUM PULL FORCES FOR INTERIOR AND EXTERIOR DOOR SHALL NOT EXCEED: 5 LBS. FOR INTERIOR DOORS / 5 LBS. FOR EXTERIOR VISITS OUR. CONST. • AS REQUIRED: MINIMUM (1) Al FIELD a COMPLIANCE DOORS / 15 LBS. FORCE FOR FIRE RATED DOORS. TURNOVER REQUIREMENTS • REPPRT. .. �£ FURNISHED BY TENANT, INSTALLED BY CONTRACTOR - (F.T.I.C.) o G.C. TO USE HARDWARE MOUNTING KIT FOR BOX LUNCH AUDIO SYSTEM • • COME RISTAL SSELY WIIH PEENANIS VENDOR W z 2 0 0 LEVER HANDLED HARDWARE SHOULD NOT REQUIRE TIGHT GRASPING, ETC. PULL FORCES SHALL NOT EXCEED: 5 LBS. FOR INT. DOORS / CONDUITS & PULL STRING .0 TO PROVIDE 1 A� C`i1NDUIT W PULL W I� 2 FURNISHED BY CONTRACTOR, INSTALLED BY CONTRACTOR - (F.C.I.C.) 5 LBS. FOR EXT. DOORS / 15 LBS. FORCE FOR FIRE RATED DOORS. POWER0FOR AUS. DIO SYS. • • CL. O TAS SCH t PINS fA�ILNPGcAn�N a o ci 0 f Q FURNISHED BY LANDLORD, INSTALLED BY CONTRACTOR - (F.L.I.C.) o ROOM IDENTIFICATION SIGNAGE, WHEN PROVIDED, SHALL COMPLY W/LOCAL AUTHORITY TELEPHONE IUIPMENT • • SHELVING AT CASHWRAP. o BOTTOM 10" AT ALL DOORS, EXCEPT AUTOMATIC DOORS, SHALL HAVE AN UNINTERRUPTED SURFACE- •",•1I '.' 5' 'y �� x �� �� �►�► '� *41/12444,40.V. �� T 2•0FURNISHED BY LANDLORD, INSTALLED BY LANDLORD - (F.L.LL.) o G.C. TO SUBMIT SHOP DRAWINGS FOR DOOR HARDWARE TO PROJECT MANAGER FOR APPROVAL PRIOR TO ORDERING. ���� 4,o..�������� ������' ������ :� `• �!� ���� E I 3 k. �. • )1/0 ,- 49 48 47 Z ' 471hir . 1Q Y � ,- f Y ilikill, t ".Q . f 1 - .:.; :A . iii EXISTING ;�J EXISTING DEMISING LEASE LINE EXISTING DEMISING -.-.-. - -- -_�...�--- --- DEMISING WALL TO REMAIN WALL TO REMAIN € WALL TO •' Pl 4.2 REMAIN '•,� ---- — -- - El 1 1 0 . ,J ;:� - ' I I REMOVE EXISTING EXIT SIGN I I I I I \"\\ - - # LEASE LINEOD TRIM EXISTIWORK NG 0TO BE Yy %i; I r7 r7 T7 Ti c7 c7 r7 t7 r7 r7 r7 r7 r7 C7 7 r7 7 r7 Ti r7 r7 r7 t7 c7 Ti Ti REMOVED - .W............ :�.� cx---x-- ==s-�----Y---_Y �l---f�.--t x �1E-- � - � ti ar x--,r.--- � ��--- ----3 =11:----ti----'� Y=cx= r� r. •'•� II SII 11r rII r I EXISTING GLAZING ' I :* — — -- II i r 11 11 i p.11 i� �- STOREFRONT & *ix r� . r� ►� If+ r'll �. �. . IF+ rill --� . �� lJ } tiJ %(J (r,;� ((5) u X75 (c5 ;r�� u u �r,;� %� �r�� CONSTRUCTION TO REMAIN. 0 b4 EXISTING DOOR TO ••1 �� �r REMOVE EXISTING FINISHES. f REMAIN- G.C. TO :i� / 4III € �r LL REPLACE HARDWARE AS •• 11 ., '''y 1 ..`. �......_. •�� r II r\ rl p r\ �i r\ �\ \\ r� r\ r\ f REQ D- SEE HARDWARE r ul %J 1J �� lb., �J • �' �J • ,� I I SCHEDULE --- 10.4 REMOVE EXISTING —EXISTING PENDANTS TO EXISTING DOOR & - SPEAKERS, TYP. I BE REMOVED IN THEIR . 2_„=,. •.0� FRAME TO REMAIN CSI ENTIRETY ..,..,._,0„0 EXISTING FINISHES, '' ,.11 REMOVE ALL EXISTING Ir'1 lr \c)w:�' I'll FLOOR FINI5HES AND REMOVE EXISTING ,,. � EXIT SIGN AND CEILING, LIGHTING AND ” UNDER LAYMENT DOWN TO REMOVE EXISTING FLOORING TO REMAIN IN ii BARE SLAB; PROVIDE A SALES COUNTERS, I PREPARE FOR NEW I 1 SEE ELEC. THIS AREA CLEAN TO 0.4 CLEAN SMOOTH SURFACE �'P• ik I L. 1 "LIKE NEW" CONDITION '•' r\ •\ r\ r\ r., r\ 0 0 r\ r\ .� .\ _ 0 lJ <J \J I , 0 EXISTING PENDANTS TO REMOVE ALL EXISTING u,� • FLOOR FINISHES AND I y; 5 BE REMOVED IN THEIR EXIST. ACT CEILING & SOFFIT TOI I UNDERLAYMENT DOWN TO I EXISTING GLASS DOOR TO REMAIN. PC • 0.4 ENTIRETY REMAIN EXIST. CAMERAS, LIGHTING, BARE SLAB; PROVIDE A G.C. TO REPLACE, IF NEEDED, m_..•_ g ETC. TO BE REMOVED- SEE SHEET IJ--I L• .�—J CLEAN SMOOTH SURFACE i 0FDR MATTE BLACK DOOR PULLS 1 •:' REMOVE EXISTING M1.0 FOR HVAC SCOPE OF WORK. I.. EXISTING RESTROOM `�I —EXISTING PENDANTS TO m _........._ FIXTURES TO SPEAKERS, TW. BE REMOVED IN THEIR I iiii....._ : REMAIN � i ENTIRETY I I eN �•� u 0LeN r% 1J %.• 4..,... pj >/ LJ 1J eN �/ 0 C=) LJ 44 n , (- --, 0 1 X711 EXISTING GLAZING --- --- -----__. —...._. V rrti nf{%1 /t ► IR% n n f(N► 10% CR% n n ftNI (0•1 f{\1 I STOREFRONT & •�4l r/ 1 r/ 1 .�/ r 1 r/ 1 r/ lr/ ll r 1 ../ 1 .+/ 1 .+) r 1EMAIN. :. Y "I" II 11`+ a .' •� •� 1 `ii •+ •� •� 1 l' I RQMOVEUEXIaTINGN O FINISHES. ��� — — rII 11ti MII II_. p.II m 1 IL —�e---� ---ve 16pr----w----'711 x R Is a --r r 1� .............. --- ICI LL LL L• LJ La LJ L♦ LL LL LL LJ LJ La LJ i La La La LJ LJ La LL LJ LL LJ LA= L �. 44 •�1 ,..........,,,,,,.....,...„,/,„.,,w,-. •1 :9: I 1 1 1 1 1 44 40.4 I 0.4 0 0 I r — 4.4 44 ••1 0.4 9 EXISTING DEMISING LEASE UNE i EXISTING DEMISING WALL TO REMAIN WALL TO REMAIN - II40.4 . . ... DEMOLITION PLAN .. _...W..� -.. . .. ..... el SCALE• 1/4' - T-0' NOTES; - __ ... �..µ ....., 1. G.C. TO VERILY ALL DIMENSIONS WITHIN (1) WEEK OF START OF PROJECT &/OR BEFORE ANY NEW CONSTRUCTION BEGINS. ANY DISCREPANCIES TO BE RESOLVED WITH BOX LUNCH PROJECT MANAGER PRIOR TO START OF FRAMING L 1 OR ROUGH-IN. mci- 2. G.C. TO INSTALL TENANT PROVIDED GRAPHICS 48 HOURS Ar IER START DATE, BARRICADE CONSTRUCTION OR RECEIPT OF GRAPHICS. MM., „j _ q - 3. CONTRACTOR TO VERIFY, PRIOR TO BIDDING, COMPLETE SCOPE OF —Q -- . _•_ DEMOLITION. ALL REQUIRED DEMOLITION TO BE INCLUDED IN THE BASE BID. DEMOLITION PLAN IS ONLY AN ESTIMATE OF SCOPE OF WORK. _ [ . .... _.-__ 'W..._.._ EXISTING STOREFRONT CONSTRUCTION Cl,... 22'-0” V.I.F. / TO REMAIN. FINISHES TO BE EXISTING SOFFIT FINISHES 4. ALL DEMOLITION WORK IS BY G.C. UNLESS NOTED OTHERWISE. y~ • IMAGE DIMENSION = LEASE LINE, WHERE OCCURS. REMOVED & PREPARE FOR NEW TO BE REMOVED tell— .. .. .. i I RETTJRN BARRICADE TO 11„,...C11 5. G.C. SHALL CONTACT THE MALL OPERATIONS MANAGER & CONFIRM THE Q NEUTRAL PIER, TYP. -� Z I --- --- -- REQUIREMENTS FOR THE STOREFRONT BARRICADE & PROVIDE ACCORDINGLY 1 LJ r LJ ' Q O II, i r7 6. G.C. TO VERIFY IF THERE ARE ANY OBSTACLES WITHIN FIRST WEEK. IF _ ... Z C THERE ARE ANY OBSTACLES IN OBTAINING PROPER SEAWALL HEIGHT t ZR LU ....... z ,, L J CONTACT BOX LUNCH PROJECT MANAGER IMMEDIATELY. = . , .. t) LL 3'-0" x 7'-O' DOOR FOR r, r� .«.:.:: Q. w ACCESS. PROVIDE & INSTALL , Z LU --\EADBOLT LOCK LEASE LINE µ �Cn _ Q d 0 I DEMOLITION NOTES; J w 1. EXISTING DEMISING WALLS -- REMOVE ALL EXISTING FIXTURES ON w O U o t - •/ =-\-- >< 1 ' W. ' ^ WALLS REPAIR, REPLACE OR INSTALL NEW 5 $" TYPE "X" I Q a / 22 -0 W. X 12 -D TALL / 2 J "? CO I Q / BARRICADE GRAPHIC CENTERED GYPSUM BOARD. ! } a N / 1 ON THE WIDTH OF BARRICADE - LEASE UNE 1 o '" / - MODIFY AS REQUIRED & 2. REMOVE ANY EXISTING FIXTURES AND MATERIALS IN SPACE. REMOVE ; • I a / I COORD W/ GRAPHIC VENDOR EXISTING CEILING AND GRID, AS NECESSARY. m cri w ( z T 3 € T '� N \ • BARRICADE - SUPPLIED I I 3. CONTRACTOR TO VERIFY CONDITION OF ANY EXISTING DOORS TO REMAIN. E & INSTALLED BY BOSTON I I VERIFY CONDITION OF HARDWARE. REPLACE IF NECESSARY. Fj BARRICADE LJ LJ . I LJ LJ PROVIDE HARDWARE AS SPEC'D ON DRAWINGS. LAJ �\ {� ,I \ \ \ . - r C 4. SEE MECH. & ELECTRICAL DRAWINGS FOR FURTHER DEMOLITION WORK. V.I.F. 1 3'-0" 5. G.C. TO VERIFY AND REMOVE ADDITIONAL ITEMS PER PLANS AS REQ'D. I V .T.c.I.F. LEASE LINE TO LEASE LINE a «.......L....... EXISTING STOREFRONT EXISTING DOORS TO EXISTING STOREFRONT 6. GENERAL CONTRACTOR TO MAINTAIN THE INTEGRITY OF ALL FIRE-RATED CONSTRUCTION TO REMAIN REMAIN CONSTRUCTION TO REMAIN CONSTRUCTION. G.C. TO REPLACE OR RELOCATE, IN ACCORDANCE W/ a 1 ' 8-2 FINISHES TO BE REMOVED & FINISHES TO BE REMOVED & LOCAL CODES, ALL FIRE SUPPRESSION & FIRE ALARM EQUIPMENT PREPARE FOR NEW PREPARE FOR NEW DISTURBED BY DEMOLITION OR CONSTRUCTION. _.'" -- • � k i �r I I O BARRICADE ELEVATION NOTES] DEMOLF11ON ELEVATION 7. REMOVE ALL DEMOLITION MATERIALS INCLUDING RUBBISH AND DEBRIS 1. CONTRACTOR TO VERIFY BARRICADE PRIOR TO NEW CONSTRUCTION. am REQUIREMENTS & COORDINATE 3 - C-1 J 9CAL.G 1/4' - 11-0' INSTALLATION W/MALL MANAGEMENT SCALE 1/4' - T-0' 8. G.C. TO REMOVE ALL FLOORING & SUB-FLOORING MATERIAL DOWN TO r Q & BOSTON BARRICADE THE SLAB. C.C. TO BEAD BLAST EXISTING SLAB. m o 9. FIRE RATING OF EXISTING FIREPROOFING TO BE MAINTAINED AT g = (`200 O.,_L. - Q FLOOR/CEILING AREAS, INCLUDING PATCHING OF DISTURBED AREAS, AND a �' EXISTING STRUCTURAL ASSEMBLIES. D1.O I ., . _..,.._ 1 1 8 �^ ,1 co , M 409 408 47-- T g z R ; 3 63'-441: ii n_11 _ "1/4V.I.F. 14 0 VII-. ; ADJACENT I o CI 1sd- I - - TENANT4.1 J o• i 1 I t 1 I i r \--\-k how I .7. .44 4.1 EXISTING - * '�•� I HALLWAY -2 \-INSTALL NEW SLATWALL Ki> INSTALL NEW SLATWALL v - ' * I ON EXISTING DEMISING + ON EXISTING DEMISING ❖, MALL I PARTITION ® PARTITION —1 A- CORRIDOR n �'' . ®` �' co ♦o• OS (*)' 5-' f•�� •,•, O . 4,i ._ 0 ov ♦�•� 6 I _ Z :4 A. o \ �. . _ 441 - INSTALL NEW 1SLATWALL I p� \ _T .,. j ON PARTTION ;�, i III i g : t G.C. TO PROVIDE FIRE I . \ .............. ~ '' 4144)//� '-, EXTINGUISHER AT LOCATION \ 5 ;.; SHOWN PER LOCAL CODE fa I co 00 MALLE t 4,4 © SALES AREAI UCOMMON ,W ON I AREA "' . ♦ :, 3 co EXISTINGt •• /- STOCKROOM � ' .1 _ ' EXISTING 1 4 OUTLINE OF - \ •••� 7 RESTROOM ' CASH/WRAP UNIT. `1 .�..., \� ,, . , .., , .. , (0,, c, ❖1 0.4.4 ro _ _ SEE FIXTURE PLAN _____________ .,,, , ... ,. 1 , Xi Immi. © C.C. TO PROVIDE %: • FIRE EXTINGUISHER _ ........,,. ....�, • 11, \ .i - - INSTALL NEW SLATWALL AT LOCATION SHOWN CASH/ 10 -INSTALL NEW SLATWALL FITTING ON EXISTING DEMISING PER LOCAL COD3E r- - ON EXISTING DEMISING ROOM PARTITION ® � i 7 3 3 PARTITION e a I n wu....... WRAP co c. <> :•:' / i' " 4 44 33 44 :44 22'-9 1/4" 8'-6" VERIFY i I 29' 1 3/4" I / 1 W1111 _. ••' / / W/ SHOP DRAWINGS 1 ' A5A "�1O'-8 3/4"3/4" V.I.F. 60'-5" V.I.F. / ams ima 5'-9 1/2' /. // I Af V.I.F. / 81'-8 7/8" LEASE LINE DIM. FLOOR PLANADJACENT Zi el TENANT ...-W.... ._.._....................I-�-�-��----..-......-_.__ 0� 8CALEI 1/4' r- 1-0' I. 1 WALL PARTITION LEGEND _...____. I F _____,._ ......._._.. ._____._____-co 1 FOR FINISH SCHEDULE SEE SHEET T2.0 I ITEM DESCRIPTIONMUM CC L� -3- GENE) NOTES; NEW FULL HEIGHT PARTITION, MIL. STUDS & FINISH ill SLATWALL "SW--1": 42 SHEETS FOR DOOR DESCRIPTION(S) LEASE UNE TO CEILING OR DECK '�' _-� CC SLATWALL "SW-2": 21 SHEETS 1 CONTRACTOR TO INCLUDE IN BASE BID TO PATCH, FLOAT OR REPLACE SEE DOOR SCHEDULE, SHEET T2,0 - - EXISTING DEMISING PARTITION -���,,,„„��� NEW PARTITION, MIL. STUDS AND GYP. BD. CO GYP. BD. ON DEMISING WALLS WHERE DAMAGED, UNSIGHTLY, OR STOPS SHORT OF CEILING OR DECK MISSING FOR AN "AS NEW" FINISHED SURFACE, NEW DEMISING PARTITION - PER MALL CRITERIA CO SALES: 1,825 SQ.FT. I I 1 hi NEW ONE-HOUR PARTITION "y ° HALLWAY: 99 SQ.FT. 1. G.C. TO VERIFY ALL DIMENSIONS WITHIN (1) WEEK OF START OF i BY LANDLORDS G.C. =" ' N 2. WRITTEN DIMENSIONS HOLD PREFERENCE OVER SCALED DIMENSIONS. DO EXISTING PARTITION TO REMAIN x PARTMON TYPE - SEE SHEET A1.0 STOCKROOM: 284 SQ.FT. NOT SCALE DRAWINGS. CONTRACTORS MUST VISIT JOB SITE TO VERIFY PROJECT WOR 6ffORE ANY NEW CONSTRUCTION BEGS. OfaI C)' RESTROOM 57 SQ.FT. All EXISTING CONDITIONS PRIOR TO SUBMITTING BIDS. DISCREPANCIES TO BE RESOLVED WITH BOX LUNCH P.M. PRIOR TO r s. R,ys,.;;: : EXISTING MASONRY DEMISING PARTITION X DOOR TYPE - SEE SHEET T2.0 /� ;' "- TOTAL BUILDING: 2,265 SQ-FT. START OF FRAYING OR ROUGH-IN. `�`° :•¢'::: V Q _ 4 , . - I I STUD GA. UNITING HT. SCHEDULE £_ _PAF I I I ION TYPE PAM 11 ION TYPE PAR i HON TYPE A, TABLE BELOW IS BASED ON THE STEEL STUD MANUFACTURERS ASSOCIATION 2015 IBCy It) Ct TECHNICAL INFORMATION CATALOG (INTERIOR WALL LIMITING HEIGHTS -- NON-COMPOSITE - 7 Imo' -� FULL DEFLECTIONFORREQUIREMENT FINISHR 5 PSF ES, WITH LATERAL LAR OF PRESSUREGYP. AND BD. PER 1/240ALLOWABLE OFO STUD. O) 10- co, STRUCTURE STRUCTURE • /.1 STRUCTURE wl • • 0 30'_0" 0 30'-0" •4.0 © 30'-0" B, SCHEDULED HEIGHTS MAY BE INCREASED BY 50% WHERE THE STUDS ARE DIAGONALLY 1 G.C. TO PATCH & FLOAT 5/8" NEW OR EXISTING BRACED AT THE MAXIMUM HEIGHT POINT TO THE STRUCTURE ABOVE 04 4'-O" O.C. TYPE 'X' GYP. BD. TO MAKE ACT CLG. SEE LIKE NEW, MAINTAIN ALL FIRE SHEET A2.0 REFLECTED C. ATP,' MANUFACTURERS USING STUDS MANUFACTURED BY A COMPANY GENERAL CONTRACTOR TO RATING REQUIREMENTS. CEILING PLAN VE IFY MANUFACTURERS STUD STRENGTH AND LIMITING HEIGHT. ADJUST GAUGE AND MAXIMUM EXISTING ACT CLG. - HEIGHT RECOMMENDED BY MANUFACTURER'S CURRENT PRINTED SPECIFICATION. 1 -EXISTING ACT SEE SHEET A2.0 -EXISTING ACT CLG. - SEE SHEET REFLECTED CBUNG CLG- - SEE SHEET Stud Stud Stud Stud Maximum A2.0 REFLECTEDWidth Type Gauge Spacing Height PiA2.D REFLECTED PLAN CEILING PLAN CEILING PLAN { 1-5/8" 1625125-30 20 GA. DRYWALL 16" 8 -5 c. \ ♦\ `� \. 162S125-33 20 GA. STRUCTURAL 16" 8'-8" 8 INSTALL NEW SLATWALL ON INSTALL NEW SLATWALL ON 2-1 2" 2505125-30 20 GA. DRYWALL 16" 11'-7" -"�EXISTING DEMISING WALL -�WALL PARTITION FROM / SALES AREA ONLY ♦_BASE TO 9'-0" A.F.F. _INSTALL NEW SLATWALL 250S125-33 20 GA. STRUCTURAL 16" 12'-0" 1 ON EXISTING PARTITION 250S125-43 18 GA. 16" 13'-0" -t EXISTING METAL STUD 1 . DEMISING WALL TO REMAIN. .-3 5/8" MTL. STUDS AT 3-5/8" 3625125-30 20 GA. DRYWALL 16" 15'-6" W 16 O.C. BY G.C. .. EXISTING METAL STUDS 362S125-33 20 GA. STRUCTURAL 16" 16'-0" a 1 WALL TO REMAIN 3 , 5/8" GYP. BD. BOTH _i i' 3625125-43 18 GA. 16" 17'-5" Z TENANT SPACL - SIDES 3625125-54 16 GA. 16" 18'-7" ....,..,_.._. _:_:: ::.:.. SALES AREA �� i STOCKROOM 362S125-68 14 GA. 16" 19'-11" �' CORRIDOR a, SALES AREA LID o NOTE_ FITTING ROOM -SECURE BOTTOM TRACK TO 6" 6005125-30 20 GA. DRYWALL 16" 22'-1 1" o o a ONEHOUR WALL PER0 CC ULC #U465 CONCRETE SLAB USING 600S125-33 20 GA. STRUCTURAL 16" 23'-9" # r POWER DRIVEN FASTENERS 600S125-43 18 GA. 16" 26'-1" Z . m .. r O MIN. .145 AT 18' O.C. 6005125-54 16 GA. 16" 27'-1 1" �- 0° �' I., � o FlNISH FLOOR 1 FINISH FLOOR FINISH FLOOR 6005125-68 14 GA. 16" 30'-0" W N.�1 .1ki i 0 O DUSTING ONE-HOUR RATED O W� MINN N.T.S. O YiALI. PARTITION N.T.S. NESTED STUD COLUMNS: SEE PLAN FOR SIZES AND GAUGE. DEMISING WALL PARTITION N.T.S. NESTED STUD BEAMS: SEE PLANS FOR SIZES AND GAUGE. A1.0 ' £ 's _L_ .,.,,,,,,, v -ilik.„,„ , _..._ ors_w.. , F., . _....Ei. ' Imo- L EXISTING DECK HT. IS EXISTING GYP. BD. CLG. : , APPROX. 3O'-0" A.F.F. 0 10'-0" A.F.F. - , !• i, G.C. TO VERIFY IN PATCH/REPAIR/CLEAN ADJACENT �r FIELD AS NEEDED. TENANT ' EXISTING HALLWAY Lri4it 11 g -4 LIGHT FIXTURE TO EXISTING GYP. BD. SOFFIT IS NEW TRACK LIGHTING W/ EXISTING GYP. BD. SOFFIT IS -- NEW TRACK LIGHTING W/ :,�, REMAIN. NEW EMERENCNEW TRACK HEADS MTD. APPROX. 10'-0' A.F.F. G.C. NEW TRACK HEADS MTD. 7;11- TO [ TGY/EXIT SIGN APPROX. 10'-0 A.F.F. G.C. TO EXISTING ACT CLG. TO VERIFY IN FIELD - PNNT TO EXISTING ACT CLG. �..,-_ . TO VERIFY IN FIELD - PAINT EXISTING LIGHT LOCATIONS P-1 EXISTING LIGHT LOCATIONS 9 1/2 7" - 5 . zi „ b ��rau. `�Qj • :::r i ` E 'H�... r # f :,-,....4 .#^:'r�k —,.YFa:c'vi' (11 'EASY GLIDE' DISPLAY - li SYSTEM ATTACHED TO ;.+ i STOREFRONT SOFFIT. G.C. :: - ' TO PAINT MATTE BLACK EXISTING Vi 4 9 r 17. HALLWAY u _ ". 0 .... a a G !! i, NEW RECESSED CAN ----1-_. MALL db P� > r6 a LIGHT TO BE INSTfU I ED Q , EQ. EQ. EQ. ECS. ► v! �� � CORRIDOR IN � �� �� IN SAME LOCATION AS .. _ � � ....,�,... .. I r►' ! , ,. CEILING MTD. c l ,.. _ d-: u u ,*. f BLACK SPEAKERS. ! I EXISTING TRACK, TYP. : -l�IP 2 y (TYP.) p!� oCEILING MTD. . p CEILING MID. n iiMIMIPIN �. � BLACK SPEAKERS. I BLACK SPEAKERS. o II 'EXIST GYP. BD. U € D (TYP.) p (TYP.) u uer O 8' I ® - `� SOFFIT - PAINT .... .-... ° ° 1 1 & , 1 'd ki _ . ip 0 - :AO ' °3'-d" '7'-0" �"°" f`' 6 -0" _ .5'-2" 2 / 3'-65 6 -C„ C,-0" • 3, 6' 0” 0 1/2' S Cr' 4. "` NEW ENTRY SOFFIT @ g §kto 1 SALES o i� AREA 10`-fl" A.F.F. - RE-CLAD 2 -7 1/2' 1 '-8 IN MATTE BLACK METAL U 5 EXISTING »„, 1=r/ -----EXISTING ACT CLG. C EXISTING ACT CLG. i / _: 1 STOCKROOM AT SALES AREA. I JI I AT SALES AREA. �rV D .......... . D s MALL a '' EXISTING ® G.C. TO REPAIR c. o G.C. TO REPAIR ► FLUORESCENT — . . ., OR REPLACE ANY I I :: I OR REPLACE ANY 4 COMMON µ"I k, LIGHT FIXTURES I ,� - DAMAGE�ILES. o D v DAMAGE LES. p AREA r v SHOPPER TRACK, _ TO REMAIN, TYP. PAINT (P_ Q PAINT P-1 NEW RECESSED CAN °>, ` - DL SEE ELEC. FOR LIGHT TO BE INSTALLED ® -----c = _ DETAILS, W..�. .--„,.I.. ,�F. EXISTING _ s,A€ N , IN SAME LOCATION AS EXISTING TYP. --(LZ) RESTROOM CEILING MTD. 6 `�` BLACK SPEAKERS. o 4 � _ �. .� I ► \ NEWSTORftRONT EXISTING RESTROOM El TYP. ;�� r, SIGN LIGHT FAN COMBO Il�r�_ 11 D� _ LIGHT/ FAN TO REMAIN `�11 ' • • o �v ,r.... .e.. _.... _. ._._ ;•v: ? :....... ....... . • I I u r r NEW EMERGENCY _� • "� ................Mi '1:.. , :Ll ?:;:Il � I iti e a u + LIG /EXIT SIGN _......_.. ... 2 a -� x- CEILING MTD. ii ii 3 iliSPEAKER S1 ' : : b hi i i _ '4 II it EXIST GYP. BD. _ MI . :: BLACK (TYP.) 0 fi gj SOFFIT PAINT" i! p o e ' ....I o .�rAsz. _ > e ji �I At: LLI CASH If RAPe 4 0o u i10 - - + r F NEW RECESSED CAN / ! [i Li - u 4i ” n A A v o n b a a n n , r LIGHT TO BE INSTAL I FD i v y A A r �._ IN SAME LOCATION AS w .._ k' EXISTING GYP. BD. CLG. a ( i r ® 8'-0 A.F.F. - I .. ¢ FITTING ° — . _ _�� » w• ii EXISTING TRACK, 7YP. 1,„- _..._._.... ........::__.._.._ i, ' PATCH REPAIR/CLEAN ' ROOM u yy s • .�: AS NEEDED. ---..�� .,..f�i.., "EASY GLJDE” DISPLAY �w, OMMUMMO / 2 9 1/27-, : EXISTING ACT CLG. 0 EXISTING ACT HT. IS — ADJACENT NEW TRACK LIGHTING W/— EXISTING ACT HT. IS APPROX. 2,'` ,,1,/ SYSTEM ATTACHED TO 11'-4" A.F.F. - APPROX. 11'-5" A.F.F. NEW TRACK HEADS MTD. TO 11'-5" A.F.F. G.C. TO VERIFY STOREFRONT SOFFIT. G.C. "' :'1`1 PATCH/REPAIR/CLEAN G.C. TO VERIFY IN FIELD TENANT EXISTING GYP. BD. SOFFIT IN FIELD TO PAINT MATTE BLACKi ill AS NEEDED. 1 G W/ NEW TRACK LIGHTING I NEW TRACK HEADS MID. ! TO EXISTING ACT CLG. 0 : REFLECTED CEILING PLAN EXISTING LIGHT LOCATIONS 3 1 SCALE 1/4' - fir ......__. ___---_ ......... ,_....._..__ 01----- , j$ i ; ! (• ICC ... ......._._ . W .- ice. s CC1 ` • CO me, co 1--,ATTACH "EASY GLIDE" - CO N - G.C. TO PROVIDE 2X FRT TRACK TO EACH METAL Z WOOD BLOCKING BETWEEN STUD, ADD BLOCKING 0 , z o) STUDS AS REQUIRED FOR BETWEEN STUDS AS REQ'D - _..__-iF M CC �/............... ATTACHMENT OF FREE !�i Cl) O STANDING POSTS TO I I _ I. mm EXISTING SOFFITLLI • "EASY GLIDE" DISPLAY EXISTING A.C.T. CEILING L- .-_-- IcTI1 i - = / T CK TYP. SEE A2.0 FOR - EIL G __ -- -- EXISTING SOFFIT �` TO REMAIN PQ, .0 LOCATION. I SEE A2.0 - PAINTED .. ...0... �r `i T.O. STRFRNT GLAZING L O, ` 0_ # c FREE-STANDING SEE A5.0 wE , £ POST - SEE A2.0 TRACK LIGHT COUPLING FOR LOCATION. IEXISTING STOREFRONT 3! f e s CONDITION MAY VARY, SEE A5.0 EMERGENCY LIGHTING NOT .,. 1 1. G.C. TO COORDINATE LOCATION OF STOCKROOM EMERGENCY LIGHTING LOCATED 0 ADJACENT TO SHELVING UNITS AND CLEAR SHELVING. VERIFY W/ BOX LUNCH P.M. Z % DISPLAY TRACK DETAIL SUSPENDED TRACK LIGHT DETAIL ! z 2LIGHTING NOME Q SCALE: 3/4'•1'-0' E' 1'SCALE - f-0'' ' . 1. FINAL LOCATIONS OF ALL TRACK LIGHTING IN SALES AREA TO BE APPROVED BY c BOX LUNCH PROJECT MANAGER. CONTRACTOR TO COORDINATE LOCATIONS WITH FINAL STORE FIXTURE LAYOUT. �R € V _ .. • REFLECTED CEILING PLAN NOTE= _ J 1. THE REFLECTED CEILING PLAN SHALL GOVERN ALL CEILING PENETRATION LOCATIONS. i W MECHANICAL DUCTWORK AND ALL ELECTRICAL CONDUITS SHALL BE RUN TO AVOID CONFLICT WITH THE REFLECTED CEILING PLAN. - G.C. SHALL NOTIFY TENANT UPON v THE START OF PROJECT OF EXISTING DUCTWORK, CONDUIT OR OTHER EXISTING Q SYSTEMS WILL CONFLICT WITH THE PROPOSED REFLECTED CEILING PLAN. NO I MODIFICATIONS TO THE REFLECTED CEILING PLAN WILL BE ACCEPTED DUE TO .w.._..._ _www. INSTALLATION OF CONTRACTOR PROVIDED SYSTEMS OR EQUIPMENT. Q f.n CO CONTRACTOR'S NOTES; Z r o a J co 1. WRITTEN DIMENSIONS HOLD PREFERENCE OVER SCALED DIMENSIONS. pO NOT SCALE c3 w LL DRAWINGS. CONTRACTORS MUST VISIT JOB SITE TO VERIFY ALL EXISTING CONDITIONS 3 E.-3 W �' & DIMENSIONS BEFORE SUBMITTING BIDS. REPORT ANY DISCREPANCIES OF ANY E a 0 I CC CONDITIONS WCH MAY INTERFERE WITH THE PROPER EXECUTION OF, TO TENANT REPRESENTATIVE. REPORT DESCREPANCIES DURING BIDDING PROCESS AND BEFORE START OF CONSTRUCTION. EXTRAS WILL NOT BE ALLOWED FOR JOB OR CODE A2.0 COMPLIANCE CONDITIONS AFTER COMMENCEMENT OF CONSTRUCTION. • tilhj lila M.." E V. Q ... WALLS: EXISTING, U.N.O � AREA MIMES E �s Ei ` I' . d6 �:... BASE: EXISTING, U.N.Od > J FLOOR: EXISTING, U.N.4 WALLS: SW-1/SW-2 TO CLG. ABOVE . Z 0 • CEILING: EXISTING, U.N.O BASE: B-1 U N.O. r W ::»:.; FLOOR: CS-1 U.N.O. � in ,- CEILING: EXISTING, U.N.O ....4' ........_00* Ft ADJACENT �� TENANT y 1. / o., IT 1l. ` ii `` if 11 ` , / 1DIVIDER I. k I y }f OIL .I DIVIDER . I � DIWIDER , , J 1 EXLSLTING - _ _ - - - I o� WAY .............._................................ .........� ..� _ _ -_ _ II I / INSTALL NEW INSTALL NEW INSTALL NEW SLATWALL INSTALL NEW INSTALL NEW SLATWALL 30"x60' 10.,,- ,- I SLATWALL OVER SLATWALL OVER OVER EXISTING WALL SLATWALL OVER OVER NEW PARTITION I "LAT FORM t �.. NEW PARTITION EXISTING COLUMN EXISTING COLUMN 1 w IT CABINET j ENCLOSURE OPEN OPEN ENCLOSURE OPEN OPEN , I J I -WA Fl �� -WA f-WAYr w1-p tj� O • DOUBLE " � ». __ � 'kiff /W • DISPLAY 1 j .. F-36 TABLE w r w cr, f 4 I � I .� _ ? _.___.__..�..._ _....___.. OM E I $ MALL EXISTING m ° -- m Z . ... .... ..., CORRIDOR SAES AREA - i r--•'� d m STOCKROOM nil Q X OPEN w Q X 3 �`° 1 _ MALL = �; � ' A 11111All 3'-8'' �-=•-� vi w u -WA 2 SMALL BASE ' COMMON oL-I mm 0 - n ---- I FIXTURE AREA w (1) 2AIOBC FIRE 4 2 - �� I . cv EXTOA a X SECURITY FIXTURES Z 4. EXTINGUISHER Q Q "'"" OPEN SEE ELECT. SHEETS ---�--�-EXISTING MALL ,A, (, .........._.._.-.._....y__ BY TENANT G.C. 2-WAY • J ;' FLOORING TO "' I Or 3 ---- _� �_ T-SHIRT g ig _— _ .... t . �� ,../.7..7._....L..._ TABLE r'') REMAIN EIERMLIINISIES _ SEE SEE 6/A3.1 FOR / �ICJ..µ, WALLS: EXISTING, ABOVE 48", • 5 ADA MODULE AREA DENOTES 44" \ I o4 CVI EXIST. BELOW, U.N.Q. a "to ACCESSIBLE ROUTE _ NSTOREFRONT SIGN BASE: EXISTING, U.N.O �_ 7 SMALL BASE 1 FLOOR: EXISTING, U.N.O © �Z �( ABOVE. SEE CEILING: EXISTING, U.N.O EXISTING :•• . ::::: FIXTURE ELEVATION =111 .-- -- - _ RESTROOM '—'� ' 30°x60' **G.C. TO DEEP CLEAN ALL ° i I r-� r-� r-� OPEN PLATFORM 3. EXISTING FINISHES & FIXTURES** = IMPULSE i r i w �W CI `l % 0 4 0 2-WAYa Y / i FIXTURE PI �;.� J 1 r � i 1 _ FIXTUR 1 � w U I. `` i { 2AIOBC FIRE 5 FITTING CASHWRAP �w ' i INSTALL NEW SLATWALL INGUISHER BY AOA INSTALL NEW Q } WO, V ROOM I ':-'0011 OVER NEW PARTITION TENANT G.C. INSTALL NEW SLAT�VALL SLATWALL OVER OVER EXISTING WALL EXISTING COLUMN I LEASE LINE _ m 1 • — -i 1 1, .�. _ . 1 ENCLOSURE .. . . -__ ...:._» M �- Lt^a TV _] i ' '_`' :.= -' —� r, M lid ■ I I �, . Ii �'■ I + tilliiii_dthilitalt.iWALLS: P-2 U.N.O / 15'-2 1/2" / 8'-6" (VERIFY W/SHOP , 29'-1 3/4" / s 3 w._ BASE: B-1 U.N.O. SLATWALL/ EDGE OF CASHWRAP DWG.) PAINT - "P-2" I SLAPNALL/ EDGE OF CASHWRAP • • FLOOR: CS-1 U.N.O. I CEILING: P-1, EXIST. ADJACENT f TENANT _ _ .,..... I , $1'-$ 7/8" LEASE LINE DIMENSION / IF:HI 3 FIXTURE / FLOOR FINISH PLAN 1 u4. - _ 0 I , - ; co w ..................... cc cc O. O i 1-- 3 N I FOR FINISH SCHEDULE SEE SHEET T2.0 I (� ch O 1- ,�k T CONTRACTOR'S NOTES: a a 111111I - ? 1. WRITTEN DIMENSIONS HOLD PREFERENCE OVER SCALED DIMENSIONS. Da __{ R NOT SCALE DRAWINGS. CONTRACTORS MUST VISIT JOB SITE TO VERIFY - ICO COry „ ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE SUBMITTING BIDS. itgr' IC) 'Q REPORT ANY DISCREPANCIES OF ANY CONDITIONS WHICH MAY INTERFERE .........:....1fra3 =fl_ -� WITH THE PROPER EXECUTION OF, TO TENANT REPRESENTATIVE. REPORT a) 0_ € Cf] DISCREPANCIES DURING BIDDING PROCESS AND BEFORE START OF CONSTRUCTION. EXTRAS WILL NOT BE ALLOWED FOR JOB OR CODE COMPLIANCE CONDITIONS AFTER COMMENCEMENT OF CONSTRUCTION. �.,., [ 1 1 2. FIXTURE PLAN, FLOOR PLAN, INTERIOR ELEVATION SHEET, REFLECTED CEILING PLAN, DEMOLITION PLAN ARE OF THE SPECIFIC STORE. DETAIL { ' FIX—URE LEGEND SHEETS ARE GENERAL AND MAY OR MAY NOT BE STORE SPECIFIC. Q HM( QWJ(11y Min DESCRIPncN o 2 0 BLACK TABLE RISER *G.C_ NUL �1 : 0_ 5 Q DIVIDER1. G.C. TO REVIEW BILL OF LADING UPON RECEIPT OF ALL SHIPMENTS. ' . I b I OPEN 2-WAY ANY DAMAGES OR SHORTAGES ARE TO BE INDICATED AT RECEIPT, OR CO WITHIN 24 HOURS. FAILURE TO DO SO WILL REQUIRE G.C. TO CONTACT I Z 4 I--1 SMALL BASE FIXTURE VENDORS LISTED ABOVE AND PURCHASE SAID ITEMS AT G.C. COST. i L.L 2 IMPULSE FIXTURE __...:.__ , —._.._._. ....._ 2. ALL OVERAGES OF TENANT SUPPLIED ITEMS ARE TO BE STORED IN I CC 1 1_I PIN FIXTURE STOCKROOM LOFT. W Q 1 [ ] T-SHIRT TABLE 3. G.C. TO PROVIDE FIRE EXTINGUISHERS AS REQUIRED BY CODE. G.C. TO ALSO PROVIDE THE FIRST SERVICE TAG WITH DATE PRIOR TO TURNOVER. I .M.."I W.. -J 2 WINDOW PLATFORM : I I 4. GC TO REPORT ANY MISSING PIECES OF VENDOR SUPPLIED SHELVING ""-"' - POST FIXTUREo ' � WITHIN 48 HOURS OF RECEIVING ORDER, FAILURE TO DO SO WILL o EaSEEI RESULT IN G.C. HAVE TO REPLACE AT OWN EXPENSE. cn n m 0) 1 w - 1 CASH WRAP - a � I CC g:1 >I 5. VENDOR TO BOLT THE SAFE TO THE FLOOR, UNDERNEATH THE z m ¢ P MANAGER'S DESK. COORDINATE WITH BOX LUNCH PROJECT MANAGER. o 4-- I o ' 1 ize DOUBLE DISPLAY TABLE — 3 w 5 6. G.C. TO ASSEMBLE ALL FIXTURES o 0 I LL 1 10` 36' ROUNDER A3.O FINISH JOINT W/ CLEAR SEALANT x__±__ €PLASTIC J-MOLD TO MATCH WAINSCOT W � 4 1.4'-0" A.F.F. i . •s ter. • 'w� - i oki o 1 EXISTING WAINSCOT ;z .11b .-._ GYP. BD. OVER METAL STUD FRAMING - *: : o • in ALUM. J-MOLD =LdaII ui �: —I O FINISH JOINT W/ CLEAR SEALANT 0 _J--- , NOT USED — 0 .. U] 1 SCALE: 6' - 1-0' NEEDS VINYL TILE COVEOR I UP WALL 6"NG° I c, _ . ._ cam...., __..__._....._......_._ I cV WATER PROOF MEMBRANE (BELOW —.) :, 0 .... .. FLOOR FINISH AND UP TO 6" ON I L. WALL) ' r` ie ■ I 0 I 0 .. I Um a 5 I 1. . ./ EXISTING CONCRETE SLAB �' '• , z.............. ,1 N 110 ....,,A0 I-- 2 N o a RESTROOM WAINSCOT DTL. d..__�... W�............ (2_ NOT USED 9CALE d' - 1-0° *WHEN REQUIRED µ 1 ,..„ F„ . SCALE 6' • 1-0' Ps rr —R- Oar .,..,,,_,,f,::;;_....± .. ... II H r--'-11-I r1 t-----I I III III I __ I III 111 I Pi BACK OF ENTRY I itit _ i iii iii STOREFRONT DOOR L__-�, y�__-� N N_a ____. yy . Ot 11 Il REDUCER STRIP -- - 1 " i SCHLUTER SCHENE m..:.. , _._. .1 f __..._� "RENO RAMP" FOR i X TRANSITION a 2 �, 1 EXISTING MALL i MAX SLOPE FLOORING ,` \ G.C. TO ENSURE DUST PROOF .v. -4.-----------EXISTING CONCRETE SLAB STRIKES ARE INSTALLED IN TILE f 1i 1 I 0 I 1 0 1 1 0 I s TILE FLOORING/CONCRt 1 t DTL. 41. , , L -- _J Li __ L - J SCALE 6 - fes' _ -- -- ,�—_�. -----------------------y Mk MI 30"X48" CLEAR 44- �` J FLOOR SPACE FUJITSU VF70 POLE DISPLAY r' ,` MONITOR Axl PER REGISTER) """"°- `" "-- !w I'�OTE:ONLY REOUIRED AT CA I L ( IMP/) I tNCTE.EACH MONITOR WIL.COME .lTb, \ --/ WITH CAKES' a - .. t....w.,..,... • 1 , FUJITSU TP-X11 PC(x1 PER REGISTER) 1e N 111111111; (NUCE_ARQWERCAk�L FOf€EACHYCWtL F ,............. _t PLAYNETWORK R4 IIKWPWIN?t: :bOX; r. MVS€c PLAYBAGIC,SY&TEA ACCESSIBLE COUNTER I ICS • 4 tet '� _ _ I I I ` 41— . . ...N». - I I z I ° AZ a g I .1;4:44),_ \ ` ..- , , ,, ,e, ii1.0., ,,,,,,, 0,,,,, s,r., ,,;,:7' fio 0 r---- -- -' %di. ,ri �' I FRONT OF CASHWRAP I ''''',..„,,....0.00. ,, , , 1 , , -1,-) I ' "ff-) „ 445%. ce s „ '` 2'-2 1/4" / >��, - .._Q LLI�.,_..._ . I i o o I Q ,It. ' 1,* (400110 1 , ,‘ gcr— 0 '-Ia.M! } CASHWRAP ADA MODULE xEROKHP ukSEI PRINTER !` I !FOR REGISTER 2 ON."; L►J ;NOTE:POikER.CASLE i JILL BE IN THE:BOxI SCALE ufi - rI BXL NEW BACKWRAP 1 BARCODE SCANNER(x1 PER REGISTER) G.C. TO SUPPLY HARDWARE o ASSEMBLY DIAGRAM 1 `•Nc�'t:x1 :a I, NCLU.o. TO AFFIX TOP BAYONET TO P (3XL FRONTWRAP STANDARD SOFFIT ABOVE. / , - "----* OPTICAL MOUSE(xi PER REGISTER) Ul 1. ADJUSTABLE BAYONET SHOULD ALWAYS BE TOWARDS SOFFIT. / [11(-40,,-- \ I MS CASH DRAWER(x1 PER REGISTER) 2. G.C. TO CUT DOWN THE TOP AFFIX POST TO BOTTOM BAYONET 1 BAYONET IF IT IS NOT EXTENDED W/ #10-16 x 0.5"L SELF TAP CD !NO'E :<1 CASLEINCLUDEUI FULLY. G.C. TO LEJ111E 2 INCHES SCREWS. PRE-DRILL HOLES INTO W J ` OF METAL ON THE TOP BAYONET BAYONETS. CONTRACTOR'S NOTES: a TO SLIDE INTO MIN4DOW POST. Q — ._ Q 1. WRITTEN DIMENSIONS HOLD PREFERENCE OVER SCALED DIMENSIONS. DO G.C. TO SUPPLY HARDWARE �` w /� NOT SCALE DRAWINGS. CONTRACTORS MUST VISIT JOB SITE TO VERIFY w► Q CASHWRAP ASSEMBLY DIAGRAM TO AFFIX BOTTOM BAYONET ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE SUBMITTING BIDS. "" c:3 N 4 f TO FLOOR BELOW. REPORT ANY DISCREPANCIES OF ANY CONDITIONS WHICH MAY INTERFERE w SCALE MITI AFFIX POST TO TOP BAYONET / [11 " WITH THE PROPER EXECUTION OF, TO TENANT REPRESENTATIVE. REPORT o co I Q) W/ #10-16 x 0.51 SELF DISCREPANCIES DURING BIDDING PROCESS AND BEFORE START OF - --� T CC• CC • TAP SCREWS. PRE-DRILL _-.0-- CONSTRUCTION. EXTRAS WILL NOT BE ALLOWED FOR JOB OR CODE r co)— ( � 0_0 \• /� HOLES INTO BAYONETS. \\„'V--- COMPLIANCE CONDITIONS AFTER COMMENCEMENT OF CONSTRUCTION. ; m Y s © = 0 2. FIXTURE PLAN, FLOOR PLAN, INTERIOR ELEVATION SHEET, REFLECTED a_ 0 n POSTDETAIL • SOFFIT POST DETAIL • FLOOR CEILING PLAN, DEMOLITION PLAN ARE OF THE SPECIFIC STORE. DETAIL _3_. SHEETS ARE GENERAL AND MAY OR MAY NOT BE STORE SPECIFIC. SCALE N.TIB SCALE N.T.8 A3.1 � ... I i `S.r''''' -".'41 0 --hi I (5 ,� s. -. chi �,, 1- a _. SECURITY CONTROLLER BOX Sc � o :i ....... REMOTE ALARM INSIDE SOFFIT. 7' VERIFY EXACT LOCATION W/ BOX rt �► BA _,x °t LUNCH P.M. I A7A © A7A �� n ,' y. 3.. (1), is 3 3 II A4.0 • at 3 3 • . l -1_ , , E . • i . , A7. I p 0 _ % 0 0 % � r;`. 1 `tom N rl —_— 4 .'.. Z . ....... . , -� — ' 5A \ti __....__. _ _ .. -r:y'..a:r 1�-:;,�;4T. Pyr. .� ,;_ _,_,.3 ti • .. : , i _ • w M �, ,..w.-a.,., 77,, , ; ��,rL�.,,..,._...../ 1 �.:�.._ _.r' -„.._..r't� y I , c_, —.. d> :- .... . __..... -. OPEN . kn i } - Z est - _:,1 /. LL_ — Fmµ- J A ),.. r—� 3 1 1W- � �✓.�.rr.. rte~3 LxL3 O 5r' � »,.r E• s r :"� O ✓� -- �/ �A , - r _ .NSA -,/ - U j A7A� th - I LL sr._. J 3 a. _., ` '� �' -J/� "��"J �f , 1w — r /:^.0 7e \ p � A r' N M i . L -- o EXISTING NEUTRALA \ -• m ,1 ( PIER BEYOND 1 • 1 ,. - `M/ on /i I f l (' ' BEHIND GRAPHIC ` _¢ . �j GLAZING. , l AND BACKWRAP7 I `f _ —I ,+ 1 E Iin - ” • x --- ; c\I OPEN - J�O' .:. i cd U- -NEW ADA EXISTING STOREFRONT SYSTEM EXISTING STOREFRONT ENTRY] 1-SECURITY FIXTURES- ' N STOREFRONTas Ei)-\ 6C� i SEE DTL. 9I A4.2E TO REMAIN DOORS TO REMAIN. G.C. TO SEE ELEC. SHEETS SYSTEM TO REMAIN A7A A7A ° Q ; & INSTALL MATTE BLACK DOOR PULLS I V 0..- e SALES AREA ELEVATION SALES AREA ELEVATION g 't SCALE 1/4' - 1'-O WALE: 114` - 1-0' _ a0a_ . IIFFI .._ 6A 6 � A7.0 A A e • 3 A7.0 f 6® A7.O - -. - . ... --... .. .__ .._ .. • • 1 -CD . SA I _ A7A ` - v \ GI1 ► i f : • i ®.. .., ,, ... .. ,. ,., i .,,... 0: ,..:, .:,.. I ✓ . . .. , r .... ,. •^•-:a' .''1 A r, r "r..:- '•'r r`.. i'; i°" 9 i / / err !,\.- / ../: �`w\ ,. / � ),...! ... k ,_�/,C � 11 y ..,. .,..... F r.. ., ., : ,. ,+� ..:. M .:.. "», .:.�.. .. ,. ,r• + i „..! .r^ w ,.i r .....,,.,✓Jd^' I 5B _�w /"... = 44/ , fir 1 l: I. .. 1 01.1 r� � A7 M � `!fir A „fav w.-- . . _fir / ,., ....... ,I t,:... . .:... ::....: ..,.....,�' w,....G+ y,... I,�,,. ga 4 " s�,,.. ,..moi„ ...,I�,,, ,�:. �( � ,L_.,. ! . �' + 1' ... . . \ (- ... ... .. /. - ( 1, i .. - .... J r r� 4 • `" i Y:w.j w EXISTING NEUTRAL - o ! �� o . . PIER, BEYOND f ' W- r - _� GLAZING. I.\ 1 ,i \ - 32"x12" S.S. KICK---/ —G.C, TO HINT \ 3 3 • mm.. ..-._ �.._._� I1P 0 PLATE MTD TO DOOR DOOR - BC / gC \ A\.....?_:� AT 1 A.F.F. A7.0 AA7O r- SALES AREA ELEVATION SALES AREA ELEVATION »..._.tH w._.w..... .4. . 3 SCALE 1/4' - 1-0' 4m: -r. 1 �iSCALES 1/4' - T-0' )j5£ 3LI............. ..- A 8'-6' GRAPHIC ---- G.C. TO PROVIDE ONE SECTION OF OSLAT ABOVE I�C:c g 1 LU . X-. BACKWRAP GRAPHIC. VERIFY WITH BOX LUNCH P.M. ICC 3 t�1 ci 0i 0 SEAMSEAM ; SEAM FINISH DRYWALL TO LEVEL N ,t N 0) 5 FINISH AND PAINT WITH i \\ P r Z 0 ..;.� AN EGGSHELL OR1121 I CS) SEMI-GLOSS PAINT 0 \ ,,, „ „:,.-, ,,,,, „,.,-' i - — I Z LLL; G.C. TO ADD PLYWOOD a,-', . ', �� r ., - " CC Ln ; � BLOCKING, AS REQUIRED, FOR SHELF AND WOOD f' » . _ ..I , FRAME SUPPORT. f , EQ 5.-9 1/4 EQ �_ •,.w..�,...._.-- _ \ ix ' _ / r - w Mr (N i r 1 r I SHELF, SUPPLJED BY r',r " L - I .» I II) VENDOR & INSTALLED x z N BY G.C. [ 1 Cl)L x.. x _ o - ---� I - . ......... �� 0 x h- O ff: t2 CD �I f ____ CG 1 o m I /%4 II �.� 0 OPEN %% Il RN.� — _ T , ------- --a __ �• - 1 1 BACKWRAP SUPPLIED f o BY VENDOR & �'__ \`` \ I '- W INSTALLED BY G.C. '� [�'� ���� \* 1 o 1 CONTRACTORS NOTES;� \�, %� OPENOPEN - � i 1. INSTALL THE 6 SHELVES & WOOD FRAME4\ ,, � '� AFTER ALL GRAPHICS HAVE BEEN INSTALLED. °C rj:11( •�_ .7-' CC . ' 2. ALL. WOOD TO BE SANDED & PRIMLU 11 v I BEFORE PAINTING, rn v.,o Q C T / G.C. TO INSTALL CONDUIT & 8'-6" VERIFY W/ SHOP DRAWINGS \+ \\ 3. G-C. MUST PAINT 2 COATS OF 'P- 2•" WITH z m ¢ co 1-ll-ll OUTLET IN THIS CABINET. SEE „' 1 EGGSHELL OR SEMI-GLOSS FINISH BEHIND Z La ,J SHEET E1.0 FOR MORE BACKWRAP; PAINT MUST BE DRY 48 HOURS 3 ce Q INFORMATION: BACKWRAP ELEVATION MIN. PRIOR TO GRAPHIC INSTALL. IF G.C. [f] FAILS TO COMPLETE PRIOR TO TECH. BEING 8CAL.E 1/2' - 1„-0' ON SITE, G.C. IS RESPONSIBLE FOR IECH.'S RETURN TRIP CHARGES. A4■0 INN • . F 1 ,.41.aa ----.0 g-i ,kzcs-i— I -: _.b w 1111 -.....: ;IE. . T.:0:LT6. 54"x60" CLEAR { �- F FLOOR SPACE { AI pi •• i O WALL HUNG MIRROR, G.C. TO E I UF INSTALL PER MANUFACTURERS . ku u m WRITTEN INSTRUCTIONS ,,� • \ FITTING ROOM HOOK, -_. . ..� � ,_...•.... ..................__.__._.. SEE DETAIL 8/A4.1 i /1 2'-4 7/8" / 3'-Q" 1'-9" I �� ' OPEN �1'-D"f 1'-6" j, 1' 6" �, W.. . DOOR FRAME, frl: £ 1 i ' SUPPLIED & /1i7//2 ] 6 - - _S --48'xCLEAR o - G.C. TO INSTALL THE (.3) o Ci I I at / FLOOR SPACE SPECIFIED HINGES SPACED o ba I - - i_ _„__ - - - - `_ oz J -- EVENLY ALONG THE EDGE /-NEW 3'-5" W. X 6'-11" o OF THE 5' 0" DOOR. i' �¢ klibma .. cv / a \ /1 HIGH FITTING ROOM1 7---,MIRROR SUPPLIED BY "' LEVER HARDWARE, I 5civ i VENDOR & INSTALLED BY 04)- SUPPLIED BY VENDOR FITTING ROOM BENCH SUPPLIED o FITTING ROOM BENCH SUPPLIED G.C. �, & INSTALLED BY G.C. ID 3'-5, 1 _.. _.._ . , _ _ . / / BY VENDOR & INSTALLED BY G.C., BY VENDOR & INSTALLED BY G.C., " 4 ; `, �,� SECURE TO WALL AS REQUIRED o "' SECURE TO WALL AS REQUIRED _.. \ 30'x 4 8 CLEAR 1 /7/ Q - _ 1 \43 FLOOR SPACE �1 DOOR, SUPPLIED BY / �� `� .....�..W_..______.__ ....... / /1 ` VENDOR & INSTALLED �" ri � BY G.C. ti :� po `�" I o _ �' I OPEN (} '--\,-_-___. _-- WO TURNING RADIUS ` 0 CID B11 O im 0 CC t a ° ,� I 1'-1 7/8" A T i ,/' 1 1 I ''',./-4_,_ :=J G.C. TO PROVIDE CONT. G.C. TO PROVIDE CONT. G.C. TO PROVIDE CONT. G.C. TO PROVIDE CONT. - --1:9:1i.-2 FITTING ROOM BENCH 2 -O , 1 -6 ,_ 1'-6" )r 1'-D/FITTING ROOM HOOK, BEAD OF CLEAR SILICONE BEAD OF CLEAR SILICONE BEAD OF CLEAR SILICONE BEAD OF CLEAR SILICONE < a! E SUPPLIED BY VENDOR & ^ ^ ' AROUND BASE IN FITTING ROOM AROUND BASE IN FITTING ROOM AROUND BASE IN FITTING ROOM AROUND BASE IN FITTING ROOM mm __ _.. ._.. INSTALLED BY G.C., SECURE / 7'-1 7/8' / SEE DETAIL 8/A4.1 TO WALL AS REQUIRED 3 - Y ri I I !NG ROOM PLAN i-i I I !NG ROOM ELEV. FITTING ROOM ELEV. FA !NG ROOM ELEV. FITTING ROOM ELEV. w it C-41 2 345 SCALE' 112' • f-0" SCALES �r • T-0' SCALE 1/2' • 1-0' SCALE 1/2' - 1-0' SALE 1/2' - f-0' 4:F NI CONT. BEAD OF CLEAR 1. DOOR 3'-4" ROUGH OPENING V.I.F. S/ � SIDILICONE ONLY�ARONGUND ROOM _ „ , •• / 2" , 3'-O" DOOR 2"/ / „______ 5/8” QYP. BD. ON '- 5/8" QYP. BD. ON _ — 3 5/8 MTL. STUDS 3 5/8 MTL. STUDS N N . i. 111 PAI T p_2 FITTING ROAM PAI T p_7 -"''� �� 3 0 3 5[8" 18 CA. METAL _ STUDS ® 16 O.C. TO FRAMING ABOVE. g 3 t.... -: 5/8" QYP. BD. ON -17M-FITTING ROOM DOOR 5/8" EYP. BD. ON � . H... �.r.....w...... 3 5/8 MTL. STUDS SEE DOOR SCHEDULE 3 5/8 MTL. STUDS d"' CO E L—KNOCKDOWN FRAME- OSB SLATWALL, - OSB SLATWALL,®— PRE-STAINED PRE-STAINED ® SEE DOOR SCHEDULE BY TENANT'S BY TENANT'S - - .._.::_.,.�...._ _... W MANUFACTURER MANUFACTURER i CO 0.. / 6" 1 ' , Fi i i !NG RM. DOOR FRAME DTL. . N -0. SCALE 3' - f-0` �.. ..5 cr)_ .o-- 5/8" QYP. BD. ON a 3 5/8 MTL STUDS 5/8" C�YP. BD. ON -tilt- ,=i . __.,-S• ` O� /'y 3 5�8 MTL. STUDS i �,• V PAINTO FITTING ROOM HOOKS _- I. n-d i�:� INSTALLED AS SHOWN, TYP f.0.. OSB SLATWALL, -- PRE FINISHED HOOK o ti 1o_ CI)l PRE-STAINED I 1 I • CONT. BEAD OF CLEAROF (6) - SUPLD BY I ` �1I SILICON AROUND DOOR BACKER BOARD, SUPPLIED BY TENANT'S I I . VENDOR & INSTL'D BY G.C. �, 1 MANUFACTURER 1 • FRAME FLING ROOM BY VENDOR & INSTALLED III SIDE 0 LY BY GC- I • 111 . ii • 1 1 - - 48" A.F.F. 4)_ r 1 . • 1 -4-w (ADA) Com} III UFlrnFM-MG ROOM Li: HOOK BACKER BOARD NOTEtI Cl] ti a G.C. TO REMOVE HOOKS FROM BACKER BOARD AND INSTALL 00,....., KNOCKDOWN FRAME- BACKER BOARD WITH SCREWS AT HOOK LOCATIONS, SO I SEE DOOR SCHEDULE SCREWS ARE HIDDEN BEHIND HOOKS. INSET SCREWS INTO BACKER BOARD SO HOOKS SET FLUSH AGAINST BACKER 11 BOARD. CAULK ALL EDGES W/ CONT.I i I I SILICONE - TYP. I__._.' -... CC FiI I !NG RM. DR. HEADER DTL. Fi I I !NG ROOM HOOKS DETAIL78CONTRACTOR'S NOTES; �, , Z SCALE 3' • 1-0' SCALE 1 u2 • 1-0' 1. WRITTEN DIMENSIONS HOLD PREFERENCE OVER SCALED DIMENSIONS. --.I. J.,DO NOT SCALE DRAWINGS. CONTRACTORS MUST VISIT JOB SITE TO I E VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE SUBMITTING .. I ..�.�. . 1 I u_ BIDS. REPORT ANY DISCREPANCIES OF ANY CONDITIONS WHICH MAY ca INTERFERE WITH THE PROPER EXECUTION OF, TO TENANT o L.0 as £ J REPRESENTATIVE. REPORT DISCREPANCIES DURING BIDDING PROCESS ,- o a 56,0 Q AND BEFORE START OF CONSTRUCTION. EXTRAS WILL NOT BE ALLOWED o m U FOR JOB OR CODE COMPLIANCE CONDITIONS AFTER COMMENCEMENT m o Q , Q. CONSTRUCTION. Z Y w I 2. FIXTURE PLAN, FLOOR PLAN, INTERIOR ELEVATION SHEET, REFLECTED a o c' "' 0 CEILING PLAN, DEMOLITION PLAN ARE OF THIS SPECIFIC STORE. DETAIL SHEETS ARE GENERAL AND MAY OR MAY NOT BE STORE SPECIFIC. A4.1 i Olt IbJ z ' 1 ,i. N. 0 • c' I" F c -ts. i - ' � O b NETWORK IT0 1i.x : 'i, /—@—/i ,7—@—/i /—®—/i. , c\I EXIST. FIXED ^�— f _• I SHELVING x I x -.4- U \ \ 1 -4- 0T U U ...•-..e - in1 VAN / '"-114 \ r vii f - I - x / ��% rx \ - x . - - x 0° w FIXEII D, LOCKABLE ` \ / w `�' v - w Jim.. .. UNIT ♦ _1 I 0 - 1 i I -� __.......__ w. : - A.O I-, K . ! ‘ in I / \ L ==== ==== ==== EXISTING FIXED J 4 ADA COMPLIANT PAINT DOOR DESK TOP 0 �. ...54...____—..„„_. I� F1XED PAINT DOOR 32" X 12" S.S. KICK SHELVING RESTROOM SIGNS. & FRAMEO & FRAME O PLATE MTD. TO DOOR EXISTING FIXED EXISTING MOBILE EXISTING FIXED jr■.•` 0.-. MTD. AT 5'-0' A.F.F. P-2 SAFE BOLTED -FILE CABINET LOCKABLE P--2 AT 1" A.F.F. SHELVING SHELVING SHELVING = SEE DTL. 9/A4.2 TO FLOOR UNIT ■ ■ eSTOCKROOM ELEVATION STOCKROOM ELEVATION STOCKROOM ELEVATIONSTOCKROOM ELEVATION LL Q l 3 4 SCALE 1/4' - 1-0' f SCALE: 1/4' - 1-0' SCALE: 1/4' - 1'-0' SCALA 114 - 1'-0' TOILET ROOM SHELVING NOTE; • G.C. TO INSTALL 12x42"x3/4" WHITE MELAMINE CLAD WOOD SHELVES ON NOTE: ANSI APPROVED E.S. PLASTIC NEMA RATED H.D. BRACKETS & ADJUSTABLE STANDARDS. MADE OF THE SAME COMPONENTS SELF EXTINGUISHING ADHEISIVE MOUNTED AS STOCK ROOM SHELVING SYSTEM. G.C. TO PROVIDE HILTI TOGGLE BOLTS & -- INSTALL PER MFR.'S INSTRUCTIONS FOR SECURE ATTACHMENT. SCREW �� - �, -- �, SHELVES TO BRACKETS THRU PROVIDED MOUNTING HOLES. SEE DTL. 12/A4.2 ---I----_ G.C. TO POSITION MIRROR • •• DOOR-MOUNTED SIGNAGE AS REQUIRED TO WHERE N -(-., N APPROPRIATE TO ROOM USE. w l 1111 it, BOTTOM OF REFLECTIVE SURFACE IS 40" A.F.F. MAX. i._ \\ \\ .\ �\ / �„ / a. !@7 I i—'-1 — - \\,^.....% ! /" MEN UNISEX 12" 3iilt is] . 011 / f / INN ; ME -GRAB BAR �"{ ' EXIST]NG LAVATORY j r \. 13'-0" G� _� \ , —� _ ` . --- : \ : �\ y EXISTING GRAB ` T�\ - ON DOORWAYS LEADING TO o A / o y I FOR PROTECTION o , INSULATE PIPE rSANITARY FACILITIES, THE �' I 't A ' BAR -� Q SYMBOLS TO BE PROVIDED ARE : ."..p -..---STRIKE SIDEIll °° A o °° o `p 0 \o "� a z I " o 1.0 tit 4 c12 EQUILATERAL TRIANGLE FOR ' Ni v "� �\ `i' �� a o o MEN OR 12" DIAMETER CIRCLE - 1 0 ---- / 'T -1-,-) 111 (S' f &- "� _i____1 - 0, - c� N `t OICI) - "' FOR WOMEN, 1/4" THICK Ink Iiii ' s "� MEN WOMEN RESTROOM / �� 4 CENTERED ON DOOR 60" ABOVE �\ -9„ 1 .�. �1!S" \ \ 8' MIN. // �1, 18" �-`EXISTING WATER • :�i► MAX. EXISTING WATER HEATER/ 17°-18# �, - FLOOR, CONTRASTING COLOR i X EXISTING WATER �� / CLOSET �� CLOSET /�7" MIN. EXISTING LAVATORY ' WITH DOOR. RAISED BRAILLE LETTERS E RESTROOM ELEV. (E)RESTROOM ELEV. (E)RESTROOM ELEV7 . C1E)RESTROOM ELEV8 . C9RESTROOM DOOR SIGNAGE s016C � CONTRACTOR'S NOTES: ............. _ ..............;. __.....-.. 1. WRITTEN DIMENSIONS HOLD PREFERENCE OVER SCALED DIMENSIONS. SCALE: 1/4' - 1-0' SCALE: 1/4' - 1- SCALE: 1/4' - 1-0' MALE: 1/4' - 1-0' 114' - 1�-0' NOT SCALE DRAWINGS. CONTRACTORS MUST VISIT JOB SITE TO VERIFY -T46%,"--r---- ALL I%`! ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE SUBMITTING BIDS. III �' REPORT ANY DISCREPANCIES OF ANY CONDITIONS WHICH MAY INTERFERE ttr WITH THE PROPER EXECUTION OF, TO TENANT REPRESENTATIVE. REPORT - DISCREPANCIES DURING BIDDING PROCESS AND BEFORE START OF W -t•• CONSTRUCTION. EXTRAS WILL NOT BE ALLOWED FOR JOB OR CODE CC COMPLIANCE CONDITIONS AFTER COMMENCEMENT OF CONSTRUCTION. Q 2•. -. LLI - G.C. TO USE 1/4" OR 1/2" HILTI I M HTB TOGGLE BOLTS TO SECURE " j STANDARDS. INSTALL PER CD 1--- MANUFACTURER'S INSTRUCTIONS. N . . 3 5/8" 20 GA. MTL. �+ 3/4" WOOD SHELVES FINISHED O Z p; C STUD DOOR HEADER lid d , W/ WHITE MELAMINE - SHELVES 1— M410N .,__. `I TO BE 3'-8" W. x 12" D. 0; .,:c O ' ...._. ...IT; 3ir1i. 7 HOLLOW METAL DOOR w FRAME AND JAMB p z Q. a2o..i... Q; �► v _ HEAVY DUTY WALL MOUNTED to O- FIRE TREATED w a 0 STANDARD SUPPLIED & m COI WOOD BLOCKING. w o w u, 3 –low INSTALLED BY G.C.--V\--: W DOOR - SEE SCHEDULE z ~ Liz z x . DOOR HEAD ,,, Lr n4 1 ^Q CL 1J ECO / 1'-0" c, O V-I 1QL VTI O V/ a KNURLED FINISHco Q 5/8" GYP. BD. BOTH (2) 3 5/8" 20 GA. "#! ALUM. GRAB BAR FASTEN BAR TO F.R. I— SIDES OVER 3 5/8" METAL STUDS WOOD BLOCKING W/(2) # 1 1/2" SCREWS ® ENDS AND �� ,`� of �'�"� I METAL STUD fr ~ HOLLOW METAL DOOR 1� CENTER SUPPORT TO••:� FRAME AND JAMB L..'., . 40" +v► irli \\ w SUPPORT 250 lbs. LOAD - I §- I— FIRE TREATED WOOD33 -36 ' �\ ( \ HEAVY DUTY MOUNTING ,,, jr BRACKET SUPPLIED & w BLOCKING. � a � Q ,N,�� NOTE; a DOOR - SEE SCHEDULE 1 9" �°,� Q °� ¢ = w NOTBROTAT MUST £ INSTALLED BY G.C. ,„ dao ND � c� � 1-1/2" 1-1/?' ROTATE IN Z I ✓ SLEEVE o I, ''. 1X1jf - :'• • '�' O w --- NOTE; _... 'r +I jr I L o o a G.C. IS TO PROVIDE THE £ 0 DOOR JAMB — SECTION A—A STANDARDS FOR RESTROOM.CC CC / 3'-0" DOOR / m I 0 , H .I-- - =CID 3'-4" ROUGH OPENING, V.I.F. Qz ( 6 - I O TYP. H.M. DOOR JAMB/HEAD DETAIL TYR RE8 1 ROOM ACC. DTL. g RESTROOM SHELF DETAIL Q tri) 1 1-- 10 ,— , ..:::t SCALE: 3' - 1-0' SCALE: N SCALE 11/2' - 1-0' >_ o Q oo r W c_) i c., N. N 0 LLl A4.2 • i 1 1 i ,... .....„____8 ii AA. • Z I 'tr1'A Or Ni", O C I = 3 leti % I -- 7'-8 7/8" 1'-0" 8'-5 7/8" 1'-0" 7'-9 1/4" «__-... - v..,, e / INSTALL NEW SLATWALL OVER // V,I.F. VJ.F. V.I.F. V.I.F. ' V.I.F. 01 3 INSTALL NEW SLATWALL OVER _... EXISTING FURRED DEMISING DOUBLE POST FIXTURE, DOUBLE POST FIXTURE, EXISTING FURRED DEMISING d 1 WALL I INSTALL PLATFORM INSTALL PLATFORM WALL BEFORE WINDOW POSTS BEFORE WINDOW POSTS r-- _ POST FIXTURE —LINE OF EXISTING POST FIXTURE ,8 . , PLATFORM GYP. BD. SOFFIT PLATFORM _................__I LEASE LINE -1 I 617 N µ f w EXISTING MALL ENTRY • W - • TILE TO REMAIN, TYP. 3' LEASE LINE 0 $ ... CC rr . - • . EXISTING PLATFORM CO TO REMAIN. MODIFY „' Q EXISTING PLATFORM - D • AS NEEDED FOR NEW TO REMAIN. MODIFY f FIXTURES - PAINT P-3 I AS NEEDED FOR NEW :A j F-= ' w t ---i- - FIXTURES - PAINT P_3 f \' € I'ii U ii _____ \\4110.. ill 3 i----,, . . U EXISTING STOREFRONT % - l DOORS TO REMAIN. 1 i Q $Z 1.1 REPLACE DOOR PULLS T I / EQ. J L0 WRAP ! LE 1 / AROUNLEASE LINE 11 71, .... ._.EQ EQ / OF .. EXISTING STOREFRONTpREFRONT BUTT JOINT METAL CLADDINGI� », OF PREFINISHED METAL GLAZING SYSTEM & FIXTURE E - i EXISTING STOREFRONT / OREFRONT CLADDING � GLAZING SYSTEM & FIXTURE - _.. f .. _ _..._. EXISTING - MDF BACKER (WHERE EXISTING SUBSTRATE. SUBSTRATE IS UNSUITABLE FOR . .7-- 1 / 28'-0" LEASE LINE DIMENSION / SMOOTH FINISH), TYP. SEAM DETAIL STOREFRONT FLOOR PLAN SCALE: 6' _ 11-01 ... _... el SCALE 1/2' - f-0' . } E "s -,..0,...... „„,„„„„„„„„,„y_. , t 1 , Ilill NEW PREFABRICATED SIGN UNIT ATTACHED TO STOREFRONT SOFFIT - SUBMIT SHOP METAL PANEL SEAMS TO DWGS. TO ALL REQUIRED AUTHORITIES FOR OF SIGN AND DOORS SIGN SHOP DRAWINGS OCCUR AS SHOWN, TYP. APPROVAL. (SEE FOR DETAILS EQUALf, LQUAL tia [ --, p ._ PREFINISHED METAL ________>-------- N//" /r /r �- CLADDING0 _ 1 ._.. 6 CC - -:.. .. ..M� METAL CLADDING PREFINISHED G im `` METAL PANEL SEAMS J u • �. ,.- .:;•.N.:.:- C. . Cl) j TO OCCUR AS N ` CV L. .... : SHOWN, TYP. 7,, 0 : ~ E .. .. 0 0 .. o.l.� O O 4 z I , I,- CZ. _%...1 ,Ne - r - �, M ;v, SEAM NOTE z 1. G.C. TOSUBMITALLSEAMSLOCATIONS TO BOXLUNCH P.M. ,_ r�LEASE LINE I- LEASE UNE FORAPPROVALPRIORTOINSTALLATIONOFMETALATCf) , 1..,0---L", - II J �� STOREFRONT. PANEL SEAM LOCATIONS THAT ARE NOT : APPROVED MAY BE REQUIRED TO BE REINSTALLED AT THE a J Y EXPENSE OF THE G.C. a) 3 � Cl) "' EXISTING STOREFRONT % o EXISTING STOREFRONT 2. ANY SEAMS IN STOREFRONT SYSTEM SILL OR HEAD SHALL w m 3 GLAZING SYSTEM GLAZING SYSTEM. GLASS LINE UP WITH EDGE OF GLASS PANELS, TYP. , a PANEL TO rttLtru. NEW o 'y ANTI-GLARE FILM m m o 3. SUBSTRATE UNDERNEATH METAL WITH A MATTE BLACK FINIH. I ' O E m I SIGNAGE NOTA 3• Q 1. G.C. TO REFER TO APPROVED SIGN SHOP DRAWINGS FOR ff FINAL PLACEMENT PRIOR TO STOREFRONT CONSTRUCTION. ' 2. SIGNAGE UNDER SEPARATE PERMIT BY SIGN VENDOR. 81 o W I... 0 / `� / STOREFRONT NOTE; 1. 1/2" GLAZING TO BE SUPPORTED BY GLAZING CHANNEL ON / V I ,, ALL SIDES. G.C. TO PROVIDE CLEAR STRUCTURAL SILICONE Q . ... .. 3 AT GLASS CHANNELS ON EACH SIDE AND AROUND ENTIRE FRAME. G.C. TO VERIFY WARRANTY WITH MANUFACTURER. Ci- 2. ALL STOREFRONT METAL TO BE POWDER COATED MATTE 7 \ BLACK. G.C. TO PROVIDE METAL SAMPLE WHEN NOT USING _ .....�........... PREFINISHED METAL EXISTING STOREFRONT DOORS TO ED METAL PREFERRED VENDOR. 1 I I I 1 O CLADDING CLADDING® REMAIN. REPLACE DOOR PULLS WITH ® MATTE BLACK PULLS 3. PAINT ALL PLYWOOD BLACK cp CC O c:. 3 ch CONTRACTOR'S NOM - o Q 4— 1 W 1. WRITTEN DIMENSIONS HOLD PREFERENCE OVER SCALED DIMENSIONS. X ' CO NOT SCALE DRAWINGS- CONTRACTORS MUST VISIT JOB SITE TO VERIFY '- ¢ O STORCC EFRONT ELEVATION ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE SUBMITTING BIDS- W 2 REPORT ANY DISCREPANCIES OF ANY CONDITIONS WHICH MAY INTERFERE 0LNCO lir - T-Or WITH THE PROPER EXECUTION OF, TO TENANT REPRESENTATIVE. REPORT DISCREPANCIES DURING BIDDING PROCESS AND BEFORE START OF CONSTRUCTION. EXTRAS WILL NOT BE ALLOWED FOR JOB OR CODE COMPLIANCE CONDITIONS AFTER COMMENCEMENT OF CONSTRUCTION. A5.0 \�� z 3 5/8" 20 GA METAL STUD DIAGONAL \ ` BRACING 0 48" O.C. IN ALTERNATE VERT( THAT THE SHOWN METHOD OF ATTACHMENT IS ACCEPTABLE WITH THE SEE STUD GA. LIMITING HT. SCHEDULE ICC ESR 4943p REV 7/11 & r \ \ / / DIRECTIONS TO STRUCTURE ABOVE. AS ICC ESR 1663 (HILTS FASTENERS) • \ A _ I J REQUIRED ON -SITE COORDINATOR. IF NOT, CONTACT ARCHITECT FOR ALTERNATE DETAIL. ON SHEET A1 .0 FOR ADDITIONAL INFO. - -- (CARR #25464} i' '‘,` T - ` `�».M ... '%)>:—.1:-- \ / 3 5/8" 20 GA METAL STUD SCAB TO R°• TOP OF PARTITION AT EACH BRACE W/ 5 8" TYPE 'X' GYP. BD. PER PLAN. 0 � �,,,. ..... . tSII (2) #10 SCREWS EA TO TOP TRACK. EXISTING METAL PAN DECK EXISTING METAL PAN DECK / i / VERIFY EXACT CONDITION. VERIFY EXACT CONDITION. \ 0 1 . , M . ' ' iti tiu v-- ikti 3 5/8" 20 GA CONT. TOP TRACK. -- \\ 3 5/8" METAL STUD FRAMING AT � ;::5 SCREWSAT EACHCONN. 3• _ UNISTRUT P5000 HS BRACE BOLTEDTCl..• V 11- CONT. UNISTRUT 0 2'-0" O.C. W/ UNIRUT CHANNEL NUTS. BOTTOM TRACK W/IDNOR METAL SUD FRAMNG AT O.C. CONT. 3 5/8" 20 GA. TOP TRACK. 20 GA SLIP TRACK W/ 1" MIN OVERLAP. SCREW TO UNISTRUT. all;i°G. TEKSCREWATEACHSTRAP VERIFY EXACT COND. AT 48" gi 1 . • EXTEND GYP. BD. TO EXISTING ROOF STRUCTURE O'C' / EXTEND GYP. BD. TO _i 5 8" TYPE 'X` GYP. BD. PER PLAN. DECK WHEN REQUIRED. _� VERIFY EXACT CONDITION. EXISTING TRUSS BEYOND DECK WHEN REQUIRED. BASE PER PLAN. 2 � / VERIFY EXACT CONDITION. t ;... 01 6" O.C. 3 5/8" MTL. STUDS ® 16" O.C. ID 4' 3 5/8" MTL. STUDS , , ICC [SR 4943p REV 7/11 & ICC ESR 4943p REV 7/11 & ICC ESR 4943p REV 7/11 & \ • .... Iet,""` ICC ESR 1663 (HILTI FASTENERS ICC [SR 1663 (HILTI FASTENERS) ICC ESR 1663 (HILTI FASTENERS) EXISTING CONCRETE SLAB _11*._ (LARR #25464) (LARR #25464) (LARR #25464) , 11..ji• M g 1 IL C5 < co i SOFFIT CONNECTION TOP OF FULL HEIGHT. INT. PARTITIONBOTTOMOFTYP. IN Cr�IOR PAr� SON AT TOP ONNECTI INTERIOR PAm 1 II SON ,CI .1'. N SCALE: r f - 1-Cr SCALE r 1-0' SCALE: r - 1-0' SCALE - r� " ... . ,M_ " ---- SCALE: u cc 6 5, g . ....._, 11 0 3 5/8" METAL STUDS AT 16" cc-O.C. TO FRAMING ABOVE. 3 5/8" METAL STUDS ® 16" I O.C. TO FRAMING ABOVE. -,,1- ' ,. •.- 11'-5' 0 5/8" TYPE 'X' GYP. BD. I I o VERIFY THAT THE SHOWN METHOD OF ICC ESR 4943p REV 7/11 & BRACING DETAIL FOR FLOOR! VERIFY THAT THE SHOWN METHOD OF ICC ESR 4943p REV 7/11 & •' • © ATTACHMENT IS ACCEPTABLE WITH ICC [SR 1663 (HILTI FASTENERS) SUPPORTED FRAMING Q ATTACHMENT IS ACCEPTABLE WITH ICC ESR 1663 HILTI FASTENERS ( ) . 0 • SLATWALL . . % ON-SITE COORDINATOR. IF NOT, CONTACTON-SITE COORDINATOR. IF NOT, CONTACT ` - � ::' (CARR #25464) (LARR #25464) TOP ARCHITECT FOR ALTERNATE DETAIL. ARCHITECT FOR ALTERNATE DETAIL. -. " jr . i• • it. _ • . i UNISTRUT P1000 CLAMPED TO �! INSTALL 6 TRIM HEAD SCREWS AS REQ'D I. � UNISTRUT P1000 CLAMPED TOP CHORD OF JOIST W r"—'1*. .... .".�. �, �•-,4-;/-,44/ • 1x1 BLACK CORNER GUARD PER MFG S INSTRUCTIONS TO PREVENT TO TOP CHORD OF JOIST --EXISTING METAL PAN DECK. UNISTRUT BEAM CLAMP 1P1386 . _ DAMAGE DURING INSTALLATION. SCREW TO BE EXISTING METAL PAN DECK. TO UNISTRUT BEAM CLAMP COUNTERSUNK AND MUST PENETRATE METAL - - STUD. G.C. TO USE PRE-FINISHED WHITE #P1386 i USE UNISTRUT P1003 W/ WIDE 0 • HEAD SCREWS IN PANELS W/ WHITE INSERTS USE UNISTRUT P1003 W/ _ BASE FLANGE AT CONDITIONS ,..__....... ...__.__..__..._ ._._._ SLATWALL ! AND PRE-FINISHED BLACK HEAD SCREWS IN WIDE BASE FLANGE AT I WHERE SOFFIT CROSSES TRUSSES. ti PANELS W/ BLACK INSERTS - - - CONDITIONS WHERE SOFFIT 1 - - - - IL 4 OUTSIDE CORNER _ __ �- i CROSSES TRUSSES. L _ _� ■�. Imo. _r . I— ...... /. , i�i ~I \ 1/2" MIN. FOR DEFLECTION. `; /— / — - (2 10 SCREWS AT EACH 3 5/8" METAL STUDS AT 16" ti _ I / / CONNECTION. / I I\L � O.C. TO FRAMING ABOVE. O( ) ## 4 ,.._...... .....—.. ... __.._�.._..... CONNECTION.SCREWS AT EACH • • / ! \ 5/8" TYPE 'X' GYP. BD. f / %/ ATTACHED GA DEEP DRAMINLEG r CONTINUOUS 20 GA. — " " '. S..J.:+..: �� v `�,.,•._. ` . / / 3 1/2" WOOD BACKING ___ _ .:._,r,;-,--/-y,: , % CONT. 20 GA SLOTTED DEEP SLATWALL LEG TRACK ATTACH TO METAL / , -- 4 1 2 WOOD BASE, SGRiBE STRAPS, ✓ " _,r : / TO FLOOR AS REQUIRED EXISTING JOIST . 4 1 xi BLACK CORNER GUARD ` — -• ' ,� 3 5/8" x GA DIAG. BRACING AT EXISTING JOIST t0 SELF TAPPING TEK SLATWALL 48" O.C. TO STRUCTURE, TYP. CREWS Al 16" O.C. E GO3 5/8" MTL STUDS j '= ® 16" O.C.in INSIDE CORNERBOTTOM j.................... I � ..v S f '! I SLATWALL CORNER DETAILS SLATWALL SEAM DETAIL TYP. DIAL. BRACING CONN. TO DECK TOP OF INT" WALL TO STRUCT1JRE , 1 , _ co 4;1. SCALE 11/2' - T-0. SCALE 11/2' - 1-0' SCALE 1' s. 1-0' SCALE 3. - 1-0, ac - - 1.:u ..-..—". INSTALL #6 TRIM HEAD SCREWS AS REQ'D PER ... '---� i CC S�TWALL INSTAL_ATION INSTRUCTIONS: MFG'S INSTRUCTIONS TO PREVENT DAMAGE DURING INSTALLATION. SCREW TO BE COUNTERSUNK AND CCI 0 CO DO NOT DAMAGE OR WASTE SLATWALL. ADDITIONAL SHEETS OF SLATWALL WILL BE AT THE EXPENSE OF THE TENANT'S G.C. 01 [•3 N MUST PENETRATE METAL STUD. G.C. TO USE PRE-FINISHED WHITE HEAD SCREWS IN PANELS W/ Z H N TENANT'S G.C. TO PROVIDE QUANTITY TAKEOFF AT BID AWARD. WHITE INSERTS AND PRE-FINISHED BLACK HEAD 1 �1 "' ""' SCREWS IN PANELS WI BLACK INSERTS rt ' A70 i 0 . r .... G.C. TO OFF SET VERTICAL SEAMS IN SLATWALL BY 4'-0" 0 INSTALL LOCATIONS OVER 8'--0' IN LENGTH. 2._.. .. 0i ,, uu...: cn _..... APPROVED ADHESIVES: 1‘4" BEAD AT 1/4" PERIMETER OF "' I, --. - ,, ,, Q "MARLITE" #C-375 CONSTRUCTION MASTIC 4 -6" D.C. SLEET. .. .. ='' I "MACCO" LIQUID NAILS #LN601 TYPICAL - _I .. 0.1 "3M" CONSTRUCTION- MASTIC • - -- - -- 0) ( Q p�} ES VE P LICATJ9N: lit <I ALWAYS APPLY SLATWALL ADHESIVE TO THE BACK OF THE PANEL. BE SURE THE EXIST. SUBSTRATE IS POROUS, STRAIGHT, CLEAN & DRY AT EA. j, r_ d �I O) 0- Cl) SUCH AS DRYWALL OR PWD. EACH 5 GALLON CAN OF ADHESIVE WILL COVER 300 SQ FT. ADHESIVE IS EASIEST TO SPREAD AT 70'F. PLANKS STUD ,- N MUST BE INSTALLED WHILE ADHESIVE IS FRESH (WITHIN 10 MINUTES). ADHESIVE ON PLANK FACE SHOULD BE REMOVED PROMPTLY WITHlik 0 TvP 4J' MINERAL SPIRITS. / 10 " i, r, / SLATWALL SEAM APPLY ADHESIVE TO THE ENTIRE BACK OF PLANK USING NOTCHED SPREADER. COVER ENTIRE BACK OF PLANK EXCEPT APPROX. 1" AT �+ - PROVIDED EDGES. USE THE NOTCHES IN THE SPREADER TO GET THE EXACT DEPTH OF ADHESIVE. AVOID TOO HEAVY A COAT. TO ASSURE -- -: " / _ PROPER RIDGES WHEN SPREADING, KEEP NOTCHES OF SPREADER IN PAIL OF WATER WHEN NOT IN USE. _ ."PII r HINT: POURING A LAYER OF WATER ON TOP OF SLATWALL #C-375 IN THE CAN KEEPS ADHESIVE FRESH, REDUCES SOLVENT ODOR, EXTENDS - r 'i� ..- - _ 11 SLATWALL INSTALLATION NOTE. o. OPEN TIME AND AIDS IN CLEANING THE SPREADER. I / ii ;: COHESIVE TECHNIQUE: - Ii 1 THE OWNER SUPPLIED SLATWALL CAN ONLY BE °� FOR FASTER BONDING, USE #C-375 AND THE FOLLOWING COHESIVE TECHNIQUE TO ENSURE TROUBLE-FREE INSTALLATION. ""„ - --...".--- -- •`�� AT EA: "'- 1 SCREW LOCATION PER o ui INSTALLED IN ONE DIRECTION. FAILURE TO -APPLY THIN COAT OF #C-375 ADHESIVE TO THE WALL USING THE FLAT EDGE OF THE SPREADER, AND ALLOW TO SKIN OVER ,y y. .STUD MFRS CRITERIA (APPROXIMATELY 10-15 MINUTES). LL -APPLY ADHESIVE TO PANEL E3ACK. FOLLOW THE INSTALLATION DETAILS WILL CO -APPLY PLANK TO WALL. FAN THE PLANK BY PRESSING AND PULLING IT FROM THE WALL. THIS RELEASES THE ADHESIVE SOLVENTS AND ADHESIVE PATTERN ».. SLATWALL SEAM RESULT IN THE GC BEING RESPONSIBLE FOR """ - Q ALLOWS THE ADHESIVE TO SET UP MORE QUICKLY. PRESS THE PLANK FIRMLY TO THE WALL FROM TOP TO BOTTOM. CHECK TO SEE THAT IT / . .. ,.". ._ .N"n" � � _ r THE COMPLETE REMOVAL AND REPLACEMENT w 11— IS PLUMB. -' CARTRIDGE ADHESIVE: EI II •t -. ;:- :: 0 IF USING CARTRIDGES #C-376, YOU MUST APPLY INA CARTRIDGE ADHESIVE: SERPENTINE PATTERN. APPLY A 1/4 BEAD AROUND THEOF ALL SLATWALL INCORRECTLY INSTALLED, §.._......_.._ .__ b._.... + ENTIRE PSERIMER AND THEN SNAKE DOWN THE PANEL EVERY 4" TO 6". COVERAGE: 30 LINEAR FEET PER 10 oz. CARTRIDGE. (2) TUBES INCLUDING ANY NECESSARY WALL REPAIR AND � PER EAI r ,1 11 --N--- ri Q U) PAINT. TIME EXTENSIONS WILL NOT BE GIVEN o m t. ' PROVIDE SOME ADDED STRENGTH TO THE PANELS - INSTALLING DIRECTLY ONTO STUDS SHOULD BE FOR APPLICATIONS THAT DO NOT _ C Z REQUIRE MAXIMUM LOAD CARRYING CAPACITIES. PANEL ADHESIVE IS RECOMMENDED FOR MORE PERMANENT INSTALLATIONS. DRYWALL SCREWS €) n I- Cn_ v Q OF THE PROPER LENGTH WORK THE BEST. DRIVE THE SCREWS THROUGH THE BACKS OF THE GROOVE (BE CAREFUL NOT TO DAMAGE THE - M FOR INCORRECTLY INSTALLED SLATWALL. Z •. rn I= GROOVE LIPS). FOR MAXIMUM LOAD LEVEL CAPACITIES, SCREWS SHOULD BE DRIVEN THROUGH EVERY OTHER GROOVE (9 INCHES APART I CO ♦ 1 VERTICALLY) AND AT EACH STUD (RECOMMENDED AT 16" O.C.). CUTTING TO SIZE SHOULD BE DONE WITH THE BLADE ENTERING THE GROOVED 4 1/2" HIGH WOOD BASE -. m �- z I .. U SIDE OF THE PANEL. THIS WILL HELP AVOID "CHIP-OUT". FOLLOW THE MOUNTING INSTRUCTIONS SHOWN ON THE BACK OF THE PANELS. SCRIBED AS REQUIRED, OVER _ " E UJ 3 1/2" WOOD BACKING E3_1 In o` _ �, TYPICAL SLATWALL ELEVATION SCALE: 1/2 - 1-0" A7.O JUL 09 2019 `% DI NO O Oj - y 76024PE r GENERAL NOTES: EARTHQUAKE DESIGN DATA: r 1 3/32" ` ORE • gr I � 9ae�'��� ,s.2o,'�P�Q', 1) DESIGN OF STEEL STORAGE SHELVING AS SHOWN BY THESE DRAWINGS AND CALCULATIONS ARE IN a) Seismic Importance Factor, IE= 1 1 3/ FAT YANG COMPLIANCE WITH THE REQUIREMENTS OF THE 2016 CBC,ASCE 7-10, &ANSI/RMIMH16.1 (2012) Risk Category II- Not Open to the Public 2) STEEL FOR ALL SHAPES IS Fy= 33 KSI (EXCEPT AS NOTED) b) Mapped Spectral Response Accelerations: 1�2r 1 1/2' '1 -co r.cpires ..., 3) ALL ANCHORS ARE HILTI HUS EZ(ESR 3027) OR APPROVED EQUAL Ss = 0,978 Si= 0.425 1 , - N c) Site Class= D (Assumed) 1��,' cr) _ c„, o 4) (E)SLAB = MIN.4"THICK CONCRETE SLAB-ON--GRADE w/F'c=2500 PSI AND MIN. 500 PSF SOIL BEARING l4 E N a' d) Spectral Response Coefficients: HIS FIl / 5) ALL SHELVING INSTALLATIONS MANUFACTURED IN CONFORMITY WITH THIS STANDARD SHALL DISPLAY l PR° > zco Sds= 0.723 5d1= 0.446 .r co IN ONE OR MORE CONSPICUOUS LOCATIONS A PERMANENT PLAQUE, EACH NOT LESS THAN 50 SQUARE f� l 1/4"0 RIVET '� e) Seismic Design Category= D INCHES IN AREA SHOWING THE MAXIMUM PERMISSIBLE UNIT LOAD PER LEVEL 6) ALL SHELVING SHALL BE IN COMPLIANCE WITH THE CURRENT RMI STANDARDS f) Basic Seismic-Force-Resisting System(s): ( ii13 q 14 GA. to 7) THE CLEAR SPACE BELOW SPRINKLERS SHALL BE A MINIMUM OF 18 INCHES BETWEEN THE TOP OF THE Non-Building Structures,Steel Shelving q �JIKIG HIGH PROFILE SHELF BEAM CL cK STORED MATERIAL AND THE CEILING SPRINKLER DEFLECTORS g) Design Base Shear=60 lb CI(1 5r'5T 8) THE SHELVING STOCKROOM WILL NOT BE OPEN TO THE PUBLIC h) Seismic Response Coefficient:Vt=0.126 170 MOM w 9) SHELVING UNIT'S MAXIMUM "OUT-OF-PLUMBNESS" SHALL BE 0.5 INCH IN 10 FT 9 i) Response Modification Factor: R=4r2 $" Pm] w 10) STORAGE SHELVING CAPACITY= 10 PSF PER LEVELU g j} Redundancy Factor: p- 1.0 '` 3' p k) Analysis Procedure per ASCE 7-10,Section 15.51 t g 1U1 ,/' q - - 0clio z c) q 0 U Y g 0 /. P r CI CV J gi LOW ciLE CI 4 UJL3w f— z• uj 0 :� IU z - mow rI �� --'.\\_,/4"0 RIVET ti v Ji- fl----5-?? ......... (0 il ci) c• i a- W' r U 15� ® L--POST 0 T—POST 4 14 GA. 14 GA. 14 GA, U /LN > LOW PROFILE SHELF BEAM 1 0 UPRIGHT STEEL POSTS 2 SHELF BEAM CONNECTIONS Q r it Q u O kr) cc cc rn OwN WO �NOTE: ANCHOR BOLTS SHALL BE LOCATED1- Ce CV A MINIMUM OF 6" FROM ANY CONCRETE < N T-POST CD CONTROL JOINTS W C5 D 01 ---. /CD % �11� L-POST r: %-I (i NOTE: THE SHELVING SHALL BE ATTACHED EXISTING WALL any .- / Z TO THE EXISTING WALL STUDS AND COVER •i: V O CONCRETE SLAB. NO NEW STUDS OR (� �/ z r In STUD WALLS ARE REQUIRED. EXISTING WOOD OR i lJ V / STEEL WALL STUD O w - 16" O.C. MAX / i (n li-1 - I rrnn I MIN. 1" l <0 , '� ,���-. 1 J V o EMBED. !/ �� 2 I 4 J Z I i� �„ I. I I ,� I � SCREW 1„ UQ = 0 PLAN VIEW - STEEL STUD WALL ' `. �( t:::. ,TII { 4 2 v) Z III % �r Q Q 11;i:5) 14x3" TEK SCREW AT 11 �•, •,y II - I ��— i� J EACH WALL STUD —SHELF BEAM II II -TYP. -REF. DETAIL 2 ,, �� 11 � ,, \ 4+ J �) -‘NS U % �J�SHELVING P05T� Q ? CXISTING STUD WALL t,1 JT____ >ti wW _ '.. a: . . . i . • .: •,' ;,.' ;�• . -<' •"'.. . i; - .'-. 0 tro) X 12 V) CL FASTEN W/ #14x1 " ASTEN W/ #14x1 " �- -- e LO O 111106044°C SHELF BEAM LONG TEK SCREW LONG TEK SCREW CO Z -REF. DETAIL 2 Q INTOIN1" EMBED. STUD WALL SHELVING LOAD ON SLAB CVS _ 4 = 100 PSF MAX al N I NOTES: V "T" POST COL. B.PL. "L" POST COL. B.PL. (V Q 1. CONTRACTOR SHALL FIELD VERIFY MINIMUM SIZE, SPACING, AND GUAGE OF EXISTING WALL STUDS. (2) 3/8"0 ANCHOR BOLTS w/ 2-1/2" (1) 3/8"0 ANCHOR BOLT w/ 2-1/2" 2. MINIMUM STEEL WALL STUD SIZE = 3625125-30 (3-5/8"x1-1/4"x20 GA.). EMBEDMENT (SEE GENERAL NOTE #3) EMBEDMENT (SEE GENERAL NOTE #3) O 3. MINIMUM WOOD WALL STUD SIZE = 2x4. 0- ANTI—TIP TRACKWALL ATTACHMENT DETAIL /� BASE PLATE AND SLAB DETAILS J (ID L1J (3) 4 5 W Z w w — NOTE: I— NOTE: FIXED/MOBILE RETAIL SHELVES SHALL BE RESTOCKED BY HAND. DO NOT USE A SHELF CONFIGURATION (LENGTH,WIDTH, NUMBER OF SHELVES)VARIES PER UNIT: SCOPE E O 1[ WORK 0 f R TO STOCK SHELVES. 25'-10 7/8" LEASE LINE � W � �_ FORKLIFT OR OTHER MECHANIZED LOAD / W - REF. SHELVING CUT SHEETS AND FIXTURE PLAN REGULARLY INSPECT SHELVING FOR DAMAGE. IF DAMAGE IS FOUND, IMMEDIATELY -ALL SHELVING TO BE WIRE GRID SHELVING ANCHORAGE OF FIXED "MANAGER'S DESK" & "LOCKABLE UNIT" SHELVING UNLOAD - CC O BACK UNITS WHERE OCCURS SHALL BE BOLTED TOGETHER WITH 1/4" UNITS. THESE DRAWINGS CONTAIN ONLY THE PLANS AND DETAILS 0 UNLOAD THE AFFECTED AREA AND REPLACE OR REPAIR ANY DAMAGED COLUMNS, BACK TO PERTAINING TO THE PROPER ANCHORAGE OF THE BACK-OF-HOUSE FIXED '=`='=5::::t.:4!"*.*N° •'`"O"•"•'`" ...Wk."•'=":..x.m="="=444.•.w""'4'=::::'=.m.:.:="=�'=""'�"'.'..45av'� ❑ BEAMS, OR OTHER STRUCTURAL COMPONENTS BOLTS AT 24" O.C.ALONG THE LENGTH OF THE POST- SHELVING SYSTEMS. REFERENCE ARCHITECTURAL PLANS FOR FULL EXTENT OF y'-0 1/2" U.LF. , �'-0 3/4" v..L. s' 3" V.I.F. �' 2" V.I.F. Y 7Q ENSURE THAT SHELVING IS NOT MODIFIED OR RE ARRANGED IN A MANNER NOT WORK. THESE SHELVING UNITS ARE NOT ACCESSIBLE TO THE GENERAL PUBLIC. W IX WITHIN THE ORIGINAL DESIGN CONFIGURATIONS -� _ v o'_ cz N� \ 42" 18" - 24" -1 _ _ _ I - Z o� > 0 U SCOPE OF WORK FOR ...... ..7.7... .....................,, ? •~ '1�� , \ DC f IX z /C) �l r'-'X rte' I o � � J SHELVING UNITS I Oma-- r., V� .71 mrd[ z7� C _ mm _ a_ y Z .. Q ,y C{q O — . ER'S -3•' o A ~ ' r N z TYPO / FILE -ZOcI(ABL � =, U)P o�� n� W O U.N.O / .. CAB. a"'T mm2- zc), W U- 218 cn cn, - no co o � � Ox OT�m� m A F `n Z 0/ U c R� ?on�zo ' J ' 70'-i 11-."1 I Ono I TI Z Q 0 CO / a Q� map �pT' LkJ - O / E7'-�" 2� Oy'T' W Z I- oI �YP / w •x- HOLD w w w ,-,,o w \ Q LLLIJZ lf) O U.N.O / El a `fn, m Im rn rn ,; w m ! I \� (� ----- CO m / I N W W W 06 W - I W W �� I n I U0 / I al ix „. / DNlDER ; PROJECT#: 19-07-038 TYP. © © / _ " o No `' I , tiwALLFIXTURES 15'-I" 3. 8„ , il . DATE: 7-09-2019 EA. POST SHEETf 1 , a F C� (i) WALL-SUPPORTED x z ( W m . I SH-'I FIXED SHELVING SIDE VIEW PARTIAL FLOOR PLAN & SHELVING RACK LAYOUT REUSE OF EOUIPMENT NOTE : HVAC SYMBOLS D HVAC + SPRINKLER KEYED NOTES O ��;` +� . EXISTING AIR CONDITIONING EQUIPMENT SHALL BE REUSED AS INDICATED 4A D -0,- 1 THE OWNER RESERVES THE RIGHT TO CHECK CONSTRUCTION SUPPLY AIR DIFFUSER O EXISTING PARALLEL FAN POWERED VAV BOX WITH ELECTRIC HEAT TO REMAIN. FIELD 8 UNDERCUT DOOR 3/4" (MIN.) TO FACILITATE AIR FLOW. COORDINATE WITH GENERAL 6 A; N ON THE DRAWINGS. POINTS OF SERVICE SHALL INCLUDE, BUT NOT BE COMPLIANCE WITH PLANS AND SPECIFICATIONS. SHOULD THE OWNER VERIFY EXACT SIZE AND LOCATION. MECHANICAL CONTRACTOR IS TO CLEAN UNIT AND O CONTRACTOR. F ° \ °`4 4. pi LIMITED TO, THE FOLLOWING: FIND CORRECTIVE WORK TO BE NECESSARY, HE WILL NOTIFY RETURN AIR GRILLE PERFORM GENERAL MAINTENANCE AS REQUIRED. REPORT ANY DEFICIENCIES TO BOX 0, I i .. CONTRACTOR OF SUCH WORK IN WRITING AND EXPECT COMPLIANCE LUNCH'S ON-SITE REPRESENTATIVE PRIOR TO SUBMITTING A BID. REFER TO SCHEDULE 9 EXISTING SPRINKLER MAIN ® 14'-0" A.F.F. FIELD VERIFY LOCATION, SIZE, AND ROUTING. t \ x - 2. REMOVE EXISTING AIR FILTERS AND REPLACE WITH NEW FILTERS. O.A. OUTDOOR AIR 0 PERFORMED WITH DUE DILIGENCE. IF ANY CORRECTIVE WORK IS FOR ADDITIONAL INFORMATION AND CFM. Lu '- DEEMED TO BE NECESSARY, THE COST OF RE-INSPECTIONS WILL BE 1O EXISTING SPRINKLER HEAD TO REMAIN. FIELD VERIFY EXACT LOCATION (TYPICAL). • \:...� 3. CHECK ALL BELTS FOR WEAR, ALIGNMENT AND PROPER TENSION BORNE BY THE CONTRACTOR. IF WORK IS REQUIRED BY OWNER IN S.A. SUPPLY AIR O2 LANDLORD'S EXISTING SUPPLY AIR MAIN. FIELD VERIFY EXACT LOCATION AND SIZE. ��i.: u... (ADJUST AND REPLACE AS NEEDED). ORDER TO IMPROVE, CHANGE OR CORRECT AIR CONDITIONING TE TOILET EXHAUST 1 1 EXISTING SUPPLY AIR DIFFUSER TO REMAIN. FIELD VERIFY EXACT LOCATION AND -... ;moi ; • OPERATIONAL CONDITIONS DUE TO: PART MALFUNCTION, WARRANTY 3 EXISTING SUPPLY AIR TAP TO VAV BOX TO REMAIN. FIELD VERIFY EXACT LOCATION AND CONDITION. CLEAN, REPAIR REPLACE, AND PAINT TO MATCH ADJACENT CEILING AS R.A.G. RETURN AIR GRILLE 4. TIGHTEN MOTOR MOUNTS AS REQUIRED. OR OTHER INABILITY TO PROVIDE THE COMFORT CONDITIONS SIZE. REPAIR/ REQUIRED BY THE STORE, CONTRACTOR SHALL BE DIRECTED BY DIFF. DIFFUSER REQUIRED. ADJUST CFM TO PLAN (TYP. OF 7). 5. INSPECT AND LUBRICATE MOTORS, BEARINGS, AND SHAFTS AS PER OWNER, TO ADDRESS THIS WORK IN A TIMELY MANNER. IF IT ® HVAC CONTRACTOR TO PROVIDE AND INSTALL NEW PROGRAMMABLE HEATING AND "'" "' " • MANUFACTURERS REQUIREMENTS. IN PARALLEL FAN POWERED VAV BOXES M MOTORIZED DAMPER 12 EXISTING RETURN AIR GRILLE TO REMAIN. FIELD VERIFY EXACT LOCATION AND ENSURE THAT FAN ONLY RUNS DURING HEATING MODE. BECOMES EVIDENT THAT THE CONTRACTOR CAN NOT ACCOMPLISH COOLING THERMOSTAT. MOUNT THERMOSTAT AT 48" ABOVE FINISHED FLOOR IN LOCATION CONDITION. CLEAN, REPAIR/REPLACE, AND PAINT TO MATCH ADJACENT CEILING AS O THE TASK, THEN AFTER 72 HOURS OF WRITTEN NOTICE, THE OWNER S SMDEVOKE DETECTION SHOWN ON PLAN (NEAR STOCKROOM DOOR). COORDINATE EXACT MOUNTING LOCATION REQUIRED. (TYP. OF 3). 6. THOROUGHLY CLEAN INTERIOR OF UNIT, BLOWER WHEEL, AND DAMPER MAY AT HIS DISCRETION TAKE OVER SUCH WORK AND BACKCHARGE WITH BOX LUNCH PM PRIOR TO INSTALL. FAILURE TO DO SO MAY RESULT IN HVAC € • THE CONTRACTOR FOR ANY CORRECTIVE WORK THAT WAS REQUIRED CT THERMOSTAT BLADES. CONTRACTOR RELOCATING T-STAT TO APPROVED LOCATION AT HVAC CONTRACTOR'S 13 EXISTING HVAC EQUIPMENT, DUCTWORK, HANGERS, ASSOCIATED CONTROLS, ETC. NOT 0 J DUE TO LACK OF PERFORMANCE, WORKMANSHIP AND/OR ADHERENCE I3 TEMPERATURE SENSOR SOLE COST. THERMOSTAT MUST BE FULLY COMPATIBLE WITH HVAC UNIT USED FOR SCHEDULED TO BE RELOCATED OR RE-USED SHALL BE DISCONNECTED AND REMOVED 7. INSPECT AND MAINTAIN ALL CONTROLS FOR UNIT. REPLACE AS TO PLANS AND SPECIFICATIONS. PROJECT. VERIFY WITH LANDLORD IF A SPECIFIC THERMOSTAT IS REQUIRED AND IF MALL FROM JOB SITE. DO NOT JUST ABANDON. FIELD VERIFY EXACT CONDITIONS ANDa U3 REQUIRED. CO SMOKE DETECTOR HAS BMS PRIOR TO PURCHASING NEW THERMOSTAT. REFER TO SHEET M2.0 FOR g F4 M.D. MANUAL DAMPER ADDITIONAL INFORMATION. LOCATIONS PRIOR TO SUBMITTING A BID. N,,,,N.. 8. CONTRACTOR MAY CLEAN AND REUSE EXISTING DUCTWORK SUPPLY AIR J A ^^ F.D. FIRE DAMPER O. EXISTING TOILET ROOM AND FIXTURES TO REMAIN. FIELD VERIFY CONDITION. ENSURE IN DIFFUSERS, AND RETURN AIR GRILLES IF THEY ARE IN GOOD CONDITION MECHANICAL CONTRACTOR'S NTRACTOR'S NOTES: OS REMOTE TEMPERATURE SENSOR FOR THERMOSTAT IN CEILING NEAR RETURN AIR GRILLE. GOOD WORKING ORDER. CLEAN AND REPAIR AS NEEDED. COORDINATE WITH BOX LUNCH AND MATCH THE SIZE AND SPECIFICATIONS OF WHAT IS CALLED OUT ON F.C. FLEXIBLE CONNECTION PRIOR TO MAKING ANY REPAIRS. , THESE CONSTRUCTION DOCUMENTS. O EXISTING SUPPLY AIR DUCTWORK TO REMAIN. FIELD VERIFY EXACT LOCATIONS. DUCT -"- f S.E. SMOKE EXHAUST IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO NOTIFY THE Q DIMENSIONS ARE CLEAR INTERNAL AIR PATH DIMENSIONS. PATCH/REPAIR/SEAL AIR 15 DEMISING WALLS NOT TO DECK TO ALLOW TRANSFER AIR BACK TO LANDLORD'S SYSTEM. lC 0 9. CONTRACTOR SHALL PROVIDE NEW DUCTWORK, SUPPLY DIFFUSERS AND ARCHITECT, LANDLORD OR TENANT OF ANY DISCREPANCIES AIR DEVICE TYPE e� TIGHT/REPLACE, AND PROVIDE NEW INSULATION AS REQUIRED. REFER TO M2.0 FOR � m � RETURN GRILLES AS NECESSARY TO SATISFY THE INTENT OF THESE ENCOUNTERED ON THE PLANS OR IN EXISTING SITE CONDITIONS AIR VOLUME IN ADDITIONAL INFORMATION. DRAWINGS. PRIOR TO SUBMISSION OF BID. CUBIC FEET MINUTE CC 10. ENTIRE HVAC SYSTEM SHALL CONFORM TO THE EXISTING BUILDING BIDDERS ARE TO VISIT THE SITE AND FAMILIARIZE THEMSELVES WITH (CFM) O7 EXISTING TOILET EXHAUST FAN AND DUCT SYSTEM TO REMAIN. CONTRACTOR SHALL V CONSTRUCTION AND ALL APPLICABLE STATE AND LOCAL CODES AND ALL EXISTING CONDITIONS AND SATISFY THEMSELVES AS TO THE NATURE DAMPER INSPECT, PERFORM GENERAL MAINTENANCE, AND CLEAN AS REQUIRED. FIELD VERIFY • 0 EXACT LOCATION AND CONDITION. 0 i N LANDLORD CRITERIA. AND SCOPE OF THE WORK. THE BASE BID SHALL REFLECT 0 SPRINKLER HEAD (..;_ { MODIFICATIONS TO SYSTEMS AND DEVICES AS REQUIRED BY STATE, (E) EXISTING C� 11. THE MECHANICAL CONTRACTOR MUST VERIFY AU.. EXISTING CONDITIONS LOCAL AND FEDERAL CODES WHETHER INDICATED OR NOT ON .._.........._. _.._. .CC ._ AND SERVICES AT THE JOB SITE. CONTRACT DOCUMENTS. THE SUBMISSIONS OF A BID WILL BE _ j ,a EVIDENCE THAT SUCH AN EXAMINATION AND COMPLIANCE WITH 12. ALL WORK SHALL BE SCHEDULED SO AS NOT TO INTERRUPT THE GOVERNING CODES/REQUIREMENTS HAS BEEN MADE. LATER CLAIMSQ NORMAL OPERATION OF OTHER CONTRACTORS. FOR LABOR, EQUIPMENT, OR MATERIALS REQUIRED, OR FOR DIFFICULTIES ENCOUNTERED WHICH COULD HAVE BEEN FORSEEN HAD 13. ALL WORK, EQUIPMENT AND ACCESSORIES TO BRING EXISTING SYSTEM AN EXAMINATION AND CODE/REQUIREMENTS REVIEW BEEN MADE, WILL TO GOOD WORKING CONDITION SHALL BE COVERED UNDER CONTRACTOR'S ORIGINAL BID AND AT NOT ADDITIONAL EXPENSE. NOT BE ALLOWED. CONTRACTOR SHALL VERIFY ALL ON SITE CONDITIONS PRIOR TO BID. 14. ENSURE HEATING COIL IS IN GOOD WORKING ORDER. REPLACE IF INSTALLATION ACCEPTANCE MAY BE SUBJECT TO CONSTRUCTION REQUIRED. REVIEW BY AN INDEPENDENT AIR CONDITIONING FIRM. EXISTING VAV BOX SCHEDULE (E)VAV-1 ac_ IS TO TEST THE EXISTING HVAC UNIT THE FIRST WEEK OF ' -- CONSTRUCTION AND SEND BACK A FULL REPORT TO BOX LUNCH PM UNIT INLET DISCHARGE OF ANY REPAIRS ABOVE AND BEYOND ORIGINAL SCOPE OF WORK. MFR. MODEL NO. FILTER SIZE SIZE SIZE SIZE _ TITUS (PARALLEL ATOP 6 14 16-1/2x 27„x20" FAN POWERED) 14-1/2 MINIMUM TOTAL FAN I:_ AIR CFM CFM VOLTS PH HZ HEATER HP MCA 560 2350 208 3 60 14 KW 3/4 56.375 NOTES: 1. OUTSIDE AIR IS PROVIDED TO SPACE THROUGH LANDLORD SUPPLY AIR TO VAV SYSTEM. 2. SEE REUSE OF EQUIPMENT NOTES. 0 ® v."., i „,,, „„_,,,,i___ _ `� d —, WO 0 O-- 10 (TYP) 0 -N...- . , " ( s Ej 1 0..S:A • (E)14"0 S.A. \0 0 1 (E}12"4� S.A. _...., :.... ..� _. _.. _. _.._ icor"- e =�1 : (TYP) @®U ®� f _ .a r _���- (E�VAV_1 .. (E)12 5 A ® �11 3W ' 1 I ® 1 (E)� S.A. I (E)16"0 S,A.$ SP a _£ . i . �� 0 • .� CO 471-Ni (E1 4"0 S.A. :' ii, 1k 0 0 0 i NCO a i - H N® Q v.:w ZO) Li ----- , 00 EX (E)10"O el— X. . ............. 1I v 400 wK cn #a ............. • a '' 19 Na a 0 Q v 0 4D Alga SP SP ,dil 0 , A' , iw, .../ N._ 4 41111. L °w di wiwg' g 0 0 ti f V 4,0 . . i 5 0 0 0Vigr 0 ;' 0— MECHANICAL PLAN g m Q SCALE: 1/4' - ILIT ce U $ Z . 0 M1.O �. HEATING. VENTILATING AND AIR CONDITIONING GENERAL DRAWINGS AND SPECIFICATIONS (CONTINUED) B. THERMOSTAT Y A. THE WORK COVERED BY THIS SECTION OF THESE SPECIFICATIONS C. SHOP DRAWINGS AND CATALOG DATA ON ALL MAJOR ITEMS OF ALL HVAC UNITS SHALL BE EQUIPPED HONEYWELL /T7350M1008 HVAC CALCULAT1ONS .. 141, ._ __ SHALL BE ACCOMPLISHED IN ACCORDANCE WITH THE RESPECTIVE EQUIPMENT AND SYSTEMS, AND OTHER SUCH ILLUSTRATIVE MATERIAL "COMMERCIAL PRO", 7-DAY PROGRAMMABLE THERMOSTAT. T-STAT -AI a i (9 43.--"r DRAWINGS, INFORMATION OR INSTRUCTIONS TO BIDDERS, GENERAL THAT MAY BE CONSIDERED NECESSARY BY THE TENANT, SHALL BE SHALL HAVE 2 HEAT/2 COOL CYCLE AND AUTO CHANGE OVER, WITH • <d �' a CONDITIONS, ADDENDA, OR DIRECTIVES WHICH MAY BE ISSUED BY SUBMITTED BY THIS CONTRACTOR IN ADEQUATE TIME TO PREVENT MODULATING CONTROL CAPABILITY. THERMOSTAT SHALL BE PROVIDED I DESIGN COOLING DESIGN HEATING -- 1t� _' - ..._. THE OWNER, SHALL BE COMPLIED WITH IN EVERY ASPECT. DELAY AND/OR CONSTRUCTION MODIFICATIONS. -i • "a / WITH REMOTE TEMPERATURE SENSOR MODEL #C7772A IN CEILING COOLING DATA AT Jun 1400 HEATING DATA AT DES HTG � � a MOUNTED MODEL. DESIGN AND STANDARD CONDITIONS FOR tu, B THE LISTING REQUIRESHEREIN NTOF AN THE ARTICLE OR MATERIAL, OPERATION FURNISH AND OR RESPONSIBILITY THERMOSTAT OPERATION SHALL BE AS FOLLOWS: COOLING OA DB I WB Sens 4 F 166 8 °F Latent HEATING OA DB / WB22.0 2.0 °F ! 18.4 °FLatent �' w " t. - A. THE CONTRACTOR WILL BE HELD RESPONSIBLE FOR THE _ o._ A N. INSTALL EACH ITEM LISTED, UNLESS SPECIFICALLY NOTED TO THE SATISFACTORY AND COMPLETE EXECUTION OF ALL WORK INCLUDEDlir ~ COOLING: ZONE LOADS Details (BTU/hr) (BTU/hr) Details (BTUIhr) (BTU/hr) -�: Ix ,-`S4 + CONTRARY. THE CONTRACTOR SHALL PERFORM EACH OPERATION IN HIS CONTRACT. HE SHALL PRODUCE COMPLETE AND FULLY 75'F MAXIMUM OCCUPIED COOLING TEMPERATURE lei -4--470- -I— , PRESCRIBED OR LISTED ACCORDING TO THE CONDITIONS STATED. OPERATIONAL SYSTEMS AND PROVIDE ALL INCIDENTAL ITEMS 2 r 85'F COOLING NIGHT SETBACK. Window & Skylight Solar Loads 0 ft 0 - 0 ft2 - - _. REQUIRED AS PART OF HIS WORK, REGARDLESS OF WHETHER SUCH2 C. REFERENCE IS MADE TO REQUISITES FOR BIDDERS AND ITEM IS PARTICULARLY SPECIFIED OR INDICATED. FOR EXAMPLE, ON HEATING: -441 I W all Transmission 0 ft 0 - 0 ft2 0 - ..__._...__�.�....�.... ..._-- CONTRACTORS UNDER OTHER SECTIONS OF THESE SPECIFICATIONS, SINK INSTALLATIONS, ESCUTCHEONS SHALL BE PROVIDED FOR 70'F MAXIMUM OCCUPIED HEATING TEMPERATURE (Roof Transmission 2055 ft2 7510 - 2055 ft2 9991 0 WHICH SHALL BE CONSIDERED BINDING, UNLESS OTHERWISE NOTED COUNTERTOP PENETRATIONS, ALTHOUGH THEY WERE NOT 60'F HEATING NIGHT SETBACK. Window Transmission 0 ft2 0 - 0 ft2 0 - p i, I I UNDER THIS SECTION. SPECIFICALLY IDENTIFIED IN THE CONTRACT DOCUMENTS. .. --Skylight Transmission 0 ft2 0 0 ft2 0 8 ,.,".,� - VERIFY WITH LANDLORD IF SUPPLY AIR IS RUN DURING UNOCCUPIED g= , SCOPE B. CONTRACTOR SHALL SUPPLY TO LANDLORD AND TENANT A CERTIFIED HOURS. IF/WHEN SYSTEM IS RUN DURING OFF HOURS SET COOLING Door Loads 0 ft2 0 - 0 ft2 0 s... A. EACH CONTRACTOR SHALL THOROUGHLY ACQUAINT HIMSELF WITH THE AIR BALANCE REPORT AT COMPLETION OF PROJECT. THIS SHALL BE TO 85'F, AND SET HEATING TO 60'F. CONSTRUCTION DETAILS, BOTH ON TENANT CONSTRUCTION DRAWINGS REQUIRED FOR BOTH REMODELED AND NEW STORES. Floor Transmission 2055 ft2 0 2055 ft2 0 - I AND LANDLORD'S AS REFERRED TO, BEFORE SUBMITTING HIS BID AS FAN: CONTINUOUS IN OCCUPIED AND RECOVERY MODE AND WITH Partitions 0 ft2 0 - 0 ft2 0 - 1�]la F g NO ALLOWANCES WILL BE MADE BECAUSE OF CONTRACTOR'S DUCTWORK HEATING OR COOLING EQUIPMENT IN UNOCCUPIED MODE. Ceiling 0 ft2 0 - 0 ft2 0 - _ R - UNFAMILIARITY WITH THESE DETAILS. A. JOINTS SHALL BE SWAGGED WITH ONE-HALF INCH (1/2") OVERLAP. Overhead Lighting 2154 W 4647 0 0 - I 1 DEADBAND: CAPABLE OF MAINTAINING A 2'F DEADBAND. ...,__ q 1 B. ALL PERFORMANCE OF CONSTRUCTION SHALL BE AS REQUIRED BY B. ALL NEW CONCEALED SUPPLY AIR DUCTS, CONCEALED RETURN AIR Task Lighting 0 W 0 - 0 0 - THE PACE OF THE GENERAL CONSTRUCTION.FURNISH ALL MATERIALS, DUCTS AND ALL OUTSIDE AIR DUCTS SHALL BE INSULATED WITH 2.5" BACKUP: CAPABLE OF MAINTAINING PROGRAMMED SETTING FOR AT EQUIPMENT, AND LABOR NECESSARY FOR A COMPLETE AND FULLY Electric Equipment 3812 W 11789 D 0 Q {R-6.0) THICK (MINIMUM) EXTERNAL ACOUSTICAL AND THERMAL LEAST 24 HOURS WITHOUT POWER. OPERATIONAL HEATING, VENTILATING, AND AIR CONDITIONING SYSTEM INSULATION WHEN LOCATED IN UNCONDITIONED SPACE. People 37 8065 16508 0 0 0 r _L § 8 ,•, -„_•••, EXCEPT AS SPECIFICALLY EXCLUDED BY DRAWINGS AND/OR BY T-STAT SHALL BE INSTALLED PER MANUFACTURERS Infiltration - 0 0 - 0 0 CO LLIll- TENANT'S DIRECTIONS. C. FLEXIBLE AIR DUCT FOR CONNECTIONS BETWEEN MAIN DUCTS AND RECOMMENDATIONS AND MOUNTED SO THAT THE HIGHEST Miscellaneous 1500 0 0 0 AIR DEVICES SHALL BE AIR DUCT LISTED BY UNDERWRITERS OPERABLE CONTROL IS NOT MORE THAN 48” A.F.F. < , INSPECTION OF SITE LABORATORIES UNDER UL STANDARD 181 AS A CLASS 1 FLEXIBLE Safety Factor 20% / 20% 6702 3302 20% 1998 0 - ® c3 A. ALL PROPOSALS SHALL PRECLUDE THAT CONTRACTOR IS FAMILIAR AIR DUCT AND COMPLY WITH NFPA STANDARDS 90A AND 90B. CONTACT THE LOCAL HONEYWELL DISTRIBUTOR FOR ORDERING. REFER >> Total Zone Loads - 40212 19809 - 11989 0 �; p - WITH JOBSITE CONDITIONS AND UTILITY LOCATIONS AND THE LACK FLEXDUCT SHALL BE FACTORY MADE AND COMPOSED OF A CPE TO KEYED NOTE 4/M1.0. Zone Conditionin - 44630 19809 11620 0 0I- OF SPECIFIC INFORMATION ON THE DRAWINGS SHALL NOT RELIEVE LINER DUCT PERMANENTLY BOUNDED TO A COATED SPRING STEEL 9 THE CONTRACTOR OF ANY RESPONSIBILITY. WIRE HELIX SUPPORTING A FIBER GLASS INSULATING BLANKET C. EXISTING PARALLEL FAN POWERED VAV BOX WITH ELECTRIC HEAT Plenum Wall Load 0% 0 - 0 0 1 r. R-6.0. A LOW PERMEABILITY OUTER VAPOR BARRIER OF FIBER UNIT TO REMAIN. REFER TO MECHANICAL PLAN FOR ADDITIONALo = B. ALL CONTRACTORS SUBMITTING PROPOSALS FOR THIS WORK SHALL GLASS REINFORCED FILM LAMINATE SHALL COMPLETE THE INFORMATION. Plenum Roof Load 50% 7510 = 0 0 - 1 i _ FIRST EXAMINE THE SITE AND ALL EXISTING CONDITIONS AFFECTING COMPOSITION. Plenum Lighting Load 20% 1470 0 0 CC - HIS WORK. ALL PROPOSALS SHALL SPECIFY, IN WRITING, ALL SUCH D. FILTERS - FILTERS SHALL BE OF THE THROW AWAY TYPE WHEREVER M..w- Q Return Fan Load 2330 CFM 0 445 CFM 0 CONDITIONS THAT MAY ALTER OR AFFECT THE WORK UNDER THIS D. ALL DUCTWORK SHALL BE DESIGNED IN ACCORDANCE WITH THE POSSIBLE. IF FILTERS ARE BY NECESSITY THE PERMANENT TYPE, ' CONTRACT. PROCEDURES DESCRIBED IN THE LATEST EDITION OF THE AMERICAN THEY MUST BE OF THE CLEANABLE, HIGH VELOCITY TYPE AND SHALL Ventilation Load 0 CFM 0 0 0 CFM 0 0 _.. __.._ SOCIETY OF HEATING REFRIGERATION AND AIR CONDITIONING BE AMERICAN AIR FILTERS, AIR MAYS, EVANS, OR APPROVED EQUAL. Supply Fan Load 2330 CFM 2591 - 445 CFM -841 - PERMITS ENGINEERS GUIDE (ASHRAE), FABRICATED AND INSTALLED IN FILTERS SHALL BE OF THE OPTIMUM THICKNESS AND DESIGN FACE ALL PERMITS AND LICENSES NECESSARY FOR THE PROPER EXECUTION ACCORDANCE WITH THE METHODS RECOMMENDED IN THE SHEET VELOCITY SHALL NOT EXCEED 550 FPM. Space Fan Coil Fans 0 0 l OF THE WORK' SHALL BE SECURED AND PAID FOR BY THE METAL AND AIR CONDITIONING CONTRACTORS NATIONAL ASSOCIATION Duct Heat Gain 1 Loss 0% 0 - 0% 0 - -. + SUBCONTRACTOR INVOLVED. (SMACNA) HVAC DUCT CONSTRUCTION STANDARDS - METAL AND SPRINKLER SYSTEM - EXISTING TO REMAIN >> Total System Loads - 56201 19809 - 10780 0 FLEXIBLE. m_ ; ____m___ CODE REQUIREMENTS Central Cooling Coil - 56201 19810 - -5440 0 EACH SUBCONTRACTOR SHALL COMPLY WITH ALL LAWS, ORDINANCES, HANGERS AND SUPPORTS A. ANY NEW SPRINKLER HEAD ADDED SHALL MATCH EXISTING TYPE. - __ y RULES AND REGULATIONS BEARING ON THE CONDUCT OF THE WORK AS A. HANGER DESIGN SHALL BE AS DESCRIBED IN THE LATEST EDITION FIELD VERIFY. Preheat Coil 0 0 DRAWN AND SPECIFIED. IF A SUBCONTRACTOR OBSERVES THAT THETerminal Ree heat Coils 0 - 16220 OF THE "SMACNA" MANUAL. REINFORCEMENT MEMBERS MAY BE USED - " IIN DRAWINGS AND SPECIFICATIONS ARE AT A VARIANCE, HE SHALL PROMPTLY TO SUPPORT DUCT SYSTEM PROVIDED DETAILS OUTLINED IN THE » Total Conditioning 56201 19810 - 10780 0 = NOTIFY THE GENERAL CONTRACTOR AND THE TENANT IN WRITING. IF ANY "SMACNA" MANUAL ARE ADHERED TO. SUBCONTRACTOR PERFORMS ANY WORK KNOWING IT TO BE CONTRARY TOKey: Positive values are clg loads Positive values are htg loads LAWS, ORDINANCES, RULES AND REGULATIONS AND WITHOUT GIVING SUCH Negative values are htg loads Negative values are clg loads B. DUCTS SHALL BE SUPPORTED AT ALL TURNS AND TRANSITIONS AND NOTICE, THE SUBCONTRACTOR SHALL BEAR ALL COSTS ARISING NOTE FOR GENERAL CONTRACTOR: THEREFROM. NOT MORE THAN 8'-0" O.C. STRAIGHT DUCTS UP TO 59" MAX. IT IS THE RESPONSIBILITY OF THE TENANT'S GENERAL CONTRACTOR TO DIMENSIONS SHALL BE SUPPORTED 6'-0" O.C. MAKE USE OF APPLICABLE NOTES AND SPECIFICATIONS LISTED ON THIS WEATHER DATA MATERIALS AND WORKMANSHIP C. ALL HORIZONTAL DUCTS HAVING A DIMENSION OF 40 INCHES AND SHEET AS THEY MAY PERTAIN TO THE SPECIFIC JOB. --- A. ALL MANUFACTURED ARTICLES, MATERIALS, AND EQUIPMENT SHALL BE Design Parameters: APPLIED AS RECOMMENDED BY THE MANUFACTURERS, AND UNLESS LESS SHALL BE SUPPORTED BY MEANS OF BAND IRON HANGERS OF .00.- *, OTHERWISE SPECIFIED SHALL BE NEW, AND FREE FROM ANY AND NO. 18 U.S. GAUGE ATTACHED TO DUCT BY MEANS OF RIVETS, ALL DEFECTS. LIKE MATERIALS USED SHALL BE OF THE SAME SCREWS OR CLAMPS, AND FASTENED TO STRUCTURE ABOVE BY City Name Portland ....,,_,,,. �.. MANUFACTURE AND QUALITY UNLESS OTHERWISE SPECIFIED. TOGGLE BOLTS OR OTHER MEANS. EACH SECTION OF DUCTWORK Location Oregon SEEMED SHALL HAVE AT LEAST ONE PAIR OF SUPPORTS. Latitude 45.6 Deg. B. ALL WORK UNDER THIS CONTRACT SHALL BE PERFORMED BY Longitude 122.6 Deg. I COMPETENT WORKMEN AND EXECUTED IN A NEAT AND WORKMANLIKE D. ALL DUCTS SHALL BE REINFORCED ACCORDING TO THE LATEST MANNER. WORK SHALL BE PROPERLY PROTECTED DURING EDITION OF "SMACNA" MANUAL. MATERIALS FOR REINFORCEMENT Elevation 39.0 ft w..._- _ CONSTRUCTION AND COMPLETION, INSTALLATION SHALL BE MEMBERS SHALL BE GALVANIZED STEEL. ALL SCREWS AND WASHERS Summer Design Dry-Bulb 90.0 °F THOROUGHLY CLEANED OF ALL DEBRIS PRESENT AS A RESULT OF SHALL BE PLATED OR GALVANIZED. Summer Coincident Wet-Bulb 67.0 °F THIS CONTRACT AND SHALL BE REMOVED FROM THE PREMISES, DO Summer Daily Range 21.6 °F „•.,.w„ • ,m + NOT ABANDON. DAMPERS Winter Design Dry-Bulb 22.0 °F —1 m..T A. VOLUME DAMPERS SHALL BE OF THE OPPOSED INTERLOCKING TYPE Winter Design Wet-Bulb 18.4 °F C. MANUFACTURERS ARE LISTED ON PLANS TO ESTABLISH A STANDARD. AS MANUFACTURED BY AMERICAN FOUNDRY AND FURNACES CO. :......... .........._ _.._...._...,.._... Atmospheric Clearness Number 1.05 THE PRODUCTS OF OTHER MANUFACTURERS WILL BE ACCEPTABLE, IF (AFFCD) OR EQUAL. BLADES SHALL BE OF NO. 16 GAUGE SHEET Average Ground Reflectance 0.20 - - • _ - IN THE OPINION OF THE TENANT, THE SUBSTITUTE MATERIAL IS OF METAL AND SHALL NOT EXCEED 48" IN LENGTH OR 12" IN WIDTH. Soil Conductivity 0.800 BTUI(hr•ft.°F) 1 1 • QUALITY EQUAL TO OR BETTER THAN THE MATERIAL SPECIFIED, AND BLADES SHALL BE ON ONE-HALF INCH (1/2") DIAMETER Local Time Zone (GMT +1- N hours) 8.0 hours WILL SERVE WITH EQUAL EFFICIENCY AND DEPENDABILITY, FOR THE RUSTPROOF AXLE. BEARINGS TO BE OF THE SELF-LUBRICATING Consider Daylight Savings Time No 'Cf' PURPOSE OF WHICH THE ITEMS SPECIFIED WERE INTENDED. ALL FERRULE TYPE. SUBSTITUTION REQUESTS SHALL BE SUBMITTED TO THE TENANT'S Current Simulation Data is Weather Data 2001 ASHRAE NlA REPRESENTATIVE FOR APPROVAL PRIOR TO ORDERING. TESTING AND ADJUSTING Handbook ....,..w.v.•..w.. a.,..„. CONTRACTOR SHALL EMPLOY AN INDEPENDENT, CERTIFIED TEST AND Design Cooling Months January to December M PROTECTION OF WORK AND PROPERTY BALANCE CONTRACTOR TO DEMONSTRATE OPERATION OF SYSTEM TO FULL 4::0' M : II:I, Ir- A. EACH SUBCONTRACTOR SHALL CONTINUOUSLY MAINTAIN ADEQUATE SATISFACTION OF TENANT, SHALL BALANCE AIR FLOW AND TEMPERATURES ;�E I(r PROTECTION OF ALL HIS WORK FROM DAMAGE AND SHALL PROTECT IN ACCORDANCE WITH AIR QUANTITIES ON DRAWINGS AND SHALL RECORD +;r'�tt d-'� -40— THE OWNER'S PROPERTY FROM INJURY OR LOSS ARISING FROM HIS VOLUME READINGS IN ACCORDANCE WITH ASHRAE AND PROVIDE SAME TO l Cn 1 (--- WORK. ANY SUCH DAMAGE, INJURY, OR LOSS, EXCEPT SUCH AS MAY TENANT AND LANDLORD'S REPRESENTATIVE. ..OV# c") BE DIRECTLY DUE TO CAUSES BEYOND HIS CONTROL AND NOT TO ( N is' „ ~- + CV O HIS FAULT OR NEGLIGENCE, SHALL BE THE RESPONSIBILITY OF THE OPERATION AND MAINTENANCE DOCUMENTATION MUST BE PROVIDED TO MI ( .o�' � ...••...__... .. SUBCONTRACTOR. HE SHALL ADEQUATELY PROTECT ADJACENT THE OWNER THAT INCLUDES AT LEAST THE FOLLOWING INFORMATION: Z 1 ♦'�` PROPERTY AS WELL. l♦�- .'. �• Q Z'` cC se A. EQUIPMENT CAPACITY (INPUT AND OUTPUT) AND REQUIRED v1 3 4o B. EACH SUBCONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS MAINTENANCE ACTIONS. M di. w FOR THE SAFETY OF THEIR EMPLOYEES ON THE WORK AND SHALL = rim, , COMPLY WITH ALL PROVISIONS OF FEDERAL, STATE AND LOCAL B. HVAC SYSTEM CONTROL MAINTENANCE AND CALIBRATION ico -Cal < m BUILDING CODES AND SAFETY LAWS TO PREVENT ACCIDENTS OR INFORMATION, INCLUDING WIRING DIAGRAMS, SCHEMATICS, AND < i fQ INJURY TO PERSONS ON OR ADJACENT TO THE PREMISES WHERE CONTROL SEQUENCE DESCRIPTIONS; DESIRED OR FIELD-DETERMINED .......f- fl—'_...._ THE WORK IS BEING PERFORMED. EACH SUBCONTRACTOR SHALL SET POINTS MUST BE PERMANENTLY RECORDED ON CONTROL 26 (Cl) MAINTAIN ALL INSURANCE REQUIRED TO PROTECT HIMSELF, THE DRAWINGS, AT CONTROL DEVICES, OR, FOR DIGITAL CONTROL OWNER AND TENANT FOR THE DURATION OF THE WORK AGAINST SYSTEMS, IN PROGRAMMING COMMENTS. j PROPERTY DAMAGE AND PUBLIC LIABILITY. 1 C. COMPLETE NARRATIVE OF HOW EACH SYSTEM IS INTENDED TO £,.r.# I CO CHANGES IN THE WORK OPERATE. THE TENANT, WITHOUT INVALIDATING THE CONTRACT, MAY ORDER EXTRA 0 WORK OR MAKE CHANGES BY ALTERING, ADDING TO, OR DEDUCTING FROM D. EWB/EDB AND LWB/LDB FOR THE COOLING/HEATING COIL. THE WORK, WITH CONTRACT SUM BEING ADJUSTED ACCORDINGLY. , Q ALL TEST AND AIR BALANCE REPORTS SHALL BE DONE BY 3RD PARTY COOPERATIONE - ALL WORK UNDER THESE SPECIFICATIONS SHALL BE ACCOMPLISHED IN MBC CERTIFIED INDEPENDENT CONTRACTOR. r U CONJUNCTION WITH OTHER CONTRACTORS AND TRADES OF THIS PROJECT CLOSEOUT REQUIREMENT 0 IN A MANNER WHICH WILL ALLOW EACH CONTRACTOR AND TRADE TENANT MUST SUBMIT AS-BUILT DRAWINGS AND CERTIFIED AIR BALANCE - ' U SUFFICIENT TIME AT THE PROPER STAGE OF CONSTRUCTION TO FULFILL REPORTS PRIOR TO CONSTRUCTION CLOSE OUT SHOWING THE EXACT I UJ HIS CONTRACTS. CONTRACTORS SHALL CONTACT OWNER FOR LOCATION OF ALL EQUIPMENT AND DUCT WORK. 0— INSTRUCTIONS SHOULD ANY QUESTIONS ARISE BETWEEN TRADES AS TO THE INSTALLATION OF LINES, DUCTS, CONDUITS, FIXTURES, OR EQUIPMENT, GUARANTEE -" """"" """""""""""""" ` OR SHOULD IT APPEAR DESIRABLE TO ANY GENERAL CONSTRUCTION ALL MATERIALS, EQUIPMENT, AND WORKMANSHIP SHALL BE GUARANTEED ""F" WHICH WOULD AFFECT THE APPEARANCE OR STRENGTH OF THE I STRUCTURE. FOR A PERIOD OF ONE (1) YEAR AFTER DATE OF ACCEPTANCE. THE COMPLETED SYSTEM SHALL BE FULLY OPERATIONAL AND ACCEPTANCE BY £ I Uj TENANT SHALL BE A CONDITION OF THIS CONTRACT. ALL WORK FOUND I�` ""` `""' I) DRAWINGS AND SPECIFICATIONS TO BE DEFECTIVE SHALL BE REPAIRED OR REPLACED BY THIS A. THE DRAWINGS DIAGRAMMATICALLY INDICATE THE LOCATIONS OF THE SUBCONTRACTOR WITHOUT ADDITIONAL COST TO THE TENANT. L_.._..._..l __J SUBCONTRACTOR VARIOUS LINES, DUCTS, CONDUITS, FIXTURES, AND EQUIPMENT AND 'Q THE METHOD OF CONNECTING AND CONTROLLING THEM. IT IS NOT 5 ♦♦ ,, INTENDED TO SHOW EVERY CONNECTION IN DETAIL AND ALL FITTINGS EQUIPMENT a) ( V `" A. EXHAUST FANS 4-- • REQUIRED FOR A COMPLETE SYSTEM. o r EXISTING TOILET EXHAUST - REFER TO M1.0 SHEET FOR ADDITIONAL z ♦ ` INFORMATION. if m o Q CO V B. SHOULD ANY CHANGES BE DEEMED NECESSARY BY THE �' z Yw CONTRACTOR, TO ANY ITEMS SHOWN ON CONTRACT DRAWINGS, SHOP w DRAWINGS, DESCRIPTIONS, AND THE REASON FOR THE PROPOSED - io a =Ico 0 CHANGES SHALL BE SUBMITTED TO THE OWNER FOR APPROVAL. M2.O A I . ,.4„,„.... L �_" i g 1 14:4 g 4- .,..4., : 0 rics.2.2-1, . g i i. ....,...,Y. 9C7 4 • I 1 Kfiklizi LP-25 I I3.�.• ® © _ 0 (E)VAV--1 LP 3 10 - S ® _ �r„_M 1 LP-8.10 12 :4 ', 30 LP--7 ,� N � '--$ _. . m. LP-23 ;'� �) '� a .w.i t” .. .m. _ OE LP-27 4��:; ..:,� " Q..... L ._..._. 41) LP-21 f LP-23 . -� LP-25T45. 'Y § ' 1 IS rn i LI- CONTROLLER "" il B.-- • CAP BOX ::::::_:µms Q _ _. ._...... �: - 15 IiR LP-15 * :. fil 0 Cr 0 4 • VD :CC ' g .:: cc LP-1 g g . , - o .. . 1 LLt., a 0 1 0 0 OO © O - ,i .1. LP-23 0 .. .. 1.- , _..�µ. �, • • ill •• 0 ..7.-- 7:::.41: { I:l11 -1- 10 LP-3 41 I,', :...: mr_. ' if Es: LP-9,11 --- _LogLP-13 LP-19 3 LP-29 23 0 I ' 4?4o.�1 if; . i O LP-2 u)) 7 © LP-6 LP-6 ) e e e P 12 22 4 ........,. • .E i _......._ POWER KEYED NOTES 1 O RUN ELECTRICAL IN 3/4" RIGID CONDUIT TO PORTAL AND UP TO SIGN. ROUTE CONDUITS AS 19 WG SECURITY SYSTEM. SEE DETAIL #2 THIS SHEET. , - SHOWN ON PLAN DOWN WALL AND THEN TO A J-BOX. RUN 1/2" MC CABLE THROUGH THE STOREFRONT SILL CHANNEL AND UP THE PORTAL TO SIGN RACEWAY. COORDINATE EXACT ® 20A RATED QUADPLEX DEDICATED RECEPTACLE WITH ISOLATED GROUND FOR SECURITY SYSTEM. _ CONFIGURATION WITH TENANT REP. AND LOCATION WITH SIGNAGE VENDOR. E.C. SHALL INSTALL SPACE IS OPEN TO DECK NO CEILING. THE AC SOURCE MUST BE A 3-WIRE 24 HOUR _._ f DISCONNECT SWITCH FOR SIGNAGE CIRCUIT(S) AS REQUIRED BY N.E.C. 600. REFER TO PLANS UNSWITCHED OUTLET WITH LESS THAN 0.5 VAC BETWEEN NEUTRAL AND GROUND. UNSHARED 1 �� 01101601 FOR NUMBER OF CIRCUITS REQUIRED. VERIFY EXACT LOCATION IN HELD. NEUTRAL AND GROUND MUST BE FROM THE DEDICATED QUADPLEX TO THE CIRCUIT BREAKER , ---'. _- Diamond Door Guard Electrical & Conduit GuidePANEL IN THE BACK. PROVIDE "LOCK-ON" DEVICE ON BREAKER AT PANEL. RACEWAY FROM (Dual Antenna) O2 DUPLEX RECEPTACLE FLUSH MOUNTED HORIZONTAL IN WALL AT 19" A.F.F. TO BOTTOM OF PLUG POWER PACK MOUNTED ABOVE ON BACK SIDE OF SOFFIT DOWN TO EACH ANTENNA. WIRE RUN t..........._. ..__�__... W... FOR GENERAL USE. CANNOT EXCEED 30 FEET AND MUST BE HIDDEN IN RACEWAY. VERIFY EXACT SPECS WITH WG I Power SECURITY ELECTRONIC CORPORATION C/O BRYAN LINSKY Co? 1 -714-730-8049 SEE DETAIL #2 - _..____ 01---i-_..._. Conditioner O RUN ELECTRICAL IN (1) 1 " AND RUN PHONES IN (1) 2""RIGID CONDUIT TO CASHWRAP. ROUTE THIS SHEET. RECEPTACLE AND COVER TO BE BLACK. 1 j CONDUITS AS SHOWN ON PLAN DOWN WALL AND BY SAW CUTTING OR CORE DRILLING FLOOR AS ,,^., 12° d` 1. 24 hour dedicated 12Uvac Non Switched circuit. REQUIRED BY LANDLORD. PATCH FLOOR AS REQUIRED. COORDINATE EXACT CONFIGURATION WITH O. E.C. SHALL FIELD VERIFY EXACT REQUIREMENTS FOR SMOKE FIRE ALARM SYSTEM. REUSE ANY ControUe Quad Outlet 2. 3 wires from outlet to Panel. TENANT REP. AND LOCATION WITH FIXTURE INSTALLER. ELECTRICAL CONDUIT AND WIRE AT EXISTING DETECTION SYSTEM. REPLACE ANY DEFECTIVE DEVICES. IF THERE IS NOT AN EXISTING —""-�; - 3. Do not share neutral or ground until termination at the panel ® hCASHWRAP TO CONNECT TO PRE-INSTALLED J-BOX FOR FINAL CONNECTION. SYSTEM, E.C. SHALL SUPPLY AND INSTALL ALL NECESSARY EQUIPMENT (SMOKE DETECTORS, wit! 4. Less than 0.5vac between neutral and ground. {.....::.::::. ... AUDIO/VISUAL ALARMS, FIRE ALARM PANEL, CONDUIT, WIRE, ETC.) FOR A NEW SYSTEM AS MAY BE lt� " "" ...__ i#W Canlroller S. Circuit breaker labeled"EA55YSTEM". O. DEDICATED DUPLEX OUTLET, (HUBBELL OR EQUAL) WITH DEDICATED GROUND, MTD. IN CASHWRAP REQUIRED BY LANDLORD AND/OR LOCAL FIRE MARSHALL. INSTALL SMOKE DETECTORS IN SUPPLY 1.cc� = COUNTER. FIELD VERIFY EXACT LOCATION WITH FIXTURE MANUFACTURER. OR RETURN DUCTWORK AS REQUIRED BY LOCAL AUTHORITY. FIELD VERIFY AND COORDINATE. E.C. TO PROVIDE ALL FIRE ALARM DRAWINGS AS REQUIRED. O DUPLEX CONVENIENCE OUTLET MOUNTED IN CASHWRAP COUNTER. FIELD VERIFY EXACT LOCATION . ` CO # WITH FIXTURE MANUFACTURER. . FOR AMP/MUSIC PLAYER AND PHONES RUN 1" CONDUITS WITH PULL STRINGS FOR SPEAKER i XIX Ceiling Line WIRING TO LOCATIONS AS DIRECTED BY THE TENANT'S MUSIC PROVIDER. ' CJ 6 (5) RJ-45 CONNECTIONS/ COMPUTER JACKS IN CASHWRAP. FIELD VERIFY EXACT LOCATION WITH Z y 111 FIXTURE MANUFACTURER AND BOX LUNCH PM. FURNISHED AND INSTALLED BY BOX LUNCH 23 DEDICATED QUADPLEX RECEPTACLE (HUBBELL OR EQUAL). MOUNTED IN BACKWRAP COUNTER AT O ZCii T �' VENDOR. — 6" ABOVE FINISHED BASE. FIELD VERIFY EXACT LOCATION WITH PM. TO LEAVE AN 18" WHIP -----i M.£ L Remote STUBBED OUT AT 18" A.F.F. IV'1 Q . Alarm O (1) PHONE JACK AT BACKWRAP, AND SPEAKER WIRING. FIELD VERIFY EXACT LOCATION WITH 1.Control cables installed by WG,concealed in " : FIXTURE MANUFACTURER AND BOX LUNCH PM. FURNISHED AND INSTALLED BY BOX LUNCH matching wirernald or chased In wall/mullion. ' TRENCH 1 " W X 1 " DEEP FOR INSTALLATION OF IN-FLOOR CONDUIT FOR WG SECURITY SYSTEM. 2.Install pull string for WG. VENDOR. TO LEAVE AN 18" WHIP STUBBED OUT AT 18" A.F.F. G.C. TO SUPPLY 3/4" PVC WITH PULL STRING AND COORDINATE WITH SYSTEM INSTALLER. PATCH " - 0,__H 4 3.If conduit used,it must be 1/4". FLOOR TO MATCH SURROUNDING FLOOR AREA. PRIOR TO TRENCHING OBTAIN LANDLORD APPROVAL. �� " Q O DEDICATED QUADPLEX RECEPTACLE, (HUBBELL OR EQUAL) MOUNTED IN WALL AT 36" A.F.F. AT CONFIRM WITH LANDLORD TRENCHING LOCATIONS DO NOT CROSS EXISTING UNDERGROUND µ"" "") ICL-°" wid ebbio I I III I1 III I I III I I III Ii 1 1111111 HAI i 1111 I I 1 I II 111dilIlIll IllIl1 Il II I STOCK ROOM DESK. a) O £CO' UTILITIES. I 1 U9 EXISTING G.F.C.I. RECEPTACLE TO REMAIN. CIRCUIT AS INDICATED. . 25 EXISTING WATER HEATER CONNECTION TO REMAIN AS IS. SHOWN FOR REFERENCE ONLY. w s-foot maximum - i Antenna Spacing O. DUPLEX RECEPTACLE FOR SHOW WINDOW FLUSH MOUNTED HORIZONTALLY ON CEILING OR ABOVE 26 EXISTING HVAC EQUIPMENT DISCONNECT AND CIRCUITING TO REMAIN. SHOWN FOR REFERENCE """ " • DISPLAY WINDOW. PER N.E.C. 210-62. RECEPTACLE= AND COVER TO BE BLACK. ONLY. Diamond / Door Guards -----_____ 47 .0EMT STUB-UP FOR ALL CASHWRAP SYSTEMS, (I.E., OUTLETS, LIGHTING, PHONES, AND LOW IF NOT EXISTING, PROVIDE G.F.C.I. SERVICE RECEPTACLE AND CIRCUIT AS INDICATED. (Antennas) '� 11 VOLTAGE SYSTEMS). EXTEND TO THE DEVICES AS REQUIRED. GANG ALL CONDUITS TOGETHER AND g z4 RRUN UNETO THE DEVICES IN THE MOST INCONSPICUOUS MANNER POSSIBLE. SEE DETAIL #3 THIS O. PANEL "LP". REFER TO PANEL SCHEDULE.• Door Door Inside Store Inside Store29 PANEL "LP2". REFER TO PANEL SCHEDULE. Q 2" CONDUIT BETWEEN IT CABINET/DATA RACK AND CASHWRAP WITH PULL STRING BY G.C. LOW o J Looking Out Looking Out 12 VOLTAGE WIRING WILL BE DONE BY BOX LUNCH. CC 30 J-BOX WITH BLACK COVER FLUSH MOUNTED IN THE CENTER OF SHOW WINDOW FOR FUTURE TV 1 Cl_ POWER- FIELD VERIFY EXACT LOCATION, AND TV REQUIREMENTS WITH BOX LUNCH PM. PROVIDE J-BOX & 3/4"C WITH PULL STRING FOR TEMPERATURE-CONTROL. COORDINATE WITH - 1 w CUSTOMER SIDE 13 MECHANICAL CONTRACTOR FOR OTHER DETAILS PRIOR TO ROUGH IN: GC/SUB IS TO CONFIRM O. J BOX AT CENTER OF BACKWRAP WITH PULL STRING FOR FUTURE TV DATA. FIELD VERIFY EXACT LOCATION WITH BOX LUNCH PM BEFORE INSTALLING SENSOR. LOCATION, MOUNTING HEIGHT, AND TV REQUIREMENTS WITH BOX LUNCH PM. DUPLEX RECEPTACLE MOUNTED IN WALL AT 96" A,F.F. IN IT CABINET/DATA RACK FOR PHONE 32 J-BOX AT CENTER OF BACKWRAP FOR FUTURE TV POWER. FIELD VERIFY EXACT LOCATION, A 0 -3� . 14 SYSTEM, ALARM, OR OTHER RELATED EQUIPMENT. QUADPLEX MOUNTED IN WALL AT 96" A.F.F. MOUNTING HEIGHT, AND TV REQUIREMENTS WITH BOX LUNCH PM. ,) i a. --k NEAR IT CABINET/DATA RACK. COORDINATE HEIGHTS WITH P.M. OR LOCATION OF IT CABINET IN 33 IF NOT EXISTING, PROVIDE A DELIVERY BUZZER SYSTEM SIMILAR OR EQUAL TO THOMAS & BETTS ,� 4 6" ARCHITECTURAL DRAWINGS. O 1 Q CD Floor p WITH TRANSFORMER, PUSH BUTTON, AND CHIME IN STOCK AND SALES TO BE EDWARDS #338-G5 .....o......w................. U ' �- T LOCATION OF SHOPPER TRAK. SEE SHEET E2.0 FOR MORE DETAIL. CHIME. E.C. SHALL PROVIDE ALL J-BOXES, CONDUITS & WIRES TO COMPLETELY INSTALL THE o I - Y._ , SYSTEM. FIELD VERIFY PRIOR TO BID. 3' C 2"-0" X 2'-0" FRT UNPAINTED PLYWOOD TELEPHONE TERMINAL BOARD (T.T.B.) MOUNT DIRECTLY r , 34 J-BOX WITH BLACK COVER FLUSH MOUNTED IN THE CENTER OF SHOW WINDOW WITH PULL tej C�Door Muliion 3 16 $FLOW THE IT CABINET. PROVIDE 1-1/4"C. TO TELCO POINT OF CONNECTION. r QO `_� STRING FOR FUTURE TV DATA. FIELD VERIFY EXACT LOCATION, AND TV REQUIREMENTS WITH BOX ,; --, = 24 HOUR TIME CLOCK MOUNTED ON WALL NEAR ELECTRICAL PANEL. LUNCH PM. LAI UN J DIAMOND DOOR GUARD SYSTEM CASHWRAP ACCESS PANEL 17 8'-1" LU WG SECURITY ALARM BOX MOUNTED ON SHELF AT 8 -1 A.F.F. IN PROTAL NEXT TO CONTROL NONE SCALE N011E 18 BOX. VERIFY AND COORDINATE EXACT LOCATION AND OTHER RELATED ELECTRICAL EQUIPMENT. SCALE E1.O • i ` . a r, . ..... . �. .... .._. !.._,I4 , 3 ! i , pi_i_ . a : re- 0 F y • \ ,...,,,,,.., 0 000 0 LP-13b ii p �` e^ � k. TYPE CD TYPE C TYPE CF �� �, i. ._...i...� ......._ , • - X TYPICAL TYPICAL TYPICAL 'i`�, EXISTING NL/EM EU ID. .... ._:..._..... ►. y y y y •__...__. • Q Y rt .- V V V � TYPE N 1 g l , 4 TYPICAL c¢ , . -- LP-5 .. , O LP--1 1 a 0 SPEAKER© • 0 SPEAKER© 0 5 SPEAKER € .w. 0 \ I\ . EXISTING �� CAG CA0 -' 0 Cr) 8 —-- NL/EM 000 7 ' * i NL TYPE CB NL NL �,' _,._, ..._. 0 irr 0 . ,. > TYPICAL \1)CA I,. • . Il : x • Q IL O 0 o O 0 0 CA 0 .::U : s I ► u 1611 !Al--Z "4 112..- — 0 LP-17 ► • 01 ► I' D p, O cy CA CAI CA CA CA CA CA CA 'g g—° I C� �-r SPEAKER © WE U g NL/EM , E TYPE XA TYPE CE �� TYPE CC O TYPICAL TYPICAL TYPICAL 000 CA 0 SPEAKER © CA AC: CA ICA 0 ca n n o n n o 0 0 0 _ 71— o ca o ' IP TYPE CG TYPICAL . I LIGHTING PLAN ,, iont — 1 SCALE' 1/4' - 1-0' -. 5 I $f 333 S iii 1 LIGHTING KEYED NOTES II . 1 y.._ w. O CONNECT FIXTURE TO UNSWITCHED LEG OF CIRCUIT INDICATED TO RENDER OPERATIONAL 24HRS A DAY. MI CATS CABLE 0 LOCATION OF SHOPPER TRAK. PROVIDE 1/2" CONDUIT W/PULL STRING FROM "•••µ• w-µ• ",•"••-"••.....,_,,. (IN CONDUIT) THE COMMUNICATIONS STRUCTURE TO A LOCATION ABOVE ENTRY SOFFIT. SEE DETAIL 3 THIS SHEET. P.O.S. CONTROLLER I ORBIT ` OR IN n ELECTRICAL CONTRACTOR SHALL REMOVE EXISTING TOGGLE SWITCH AND i - STORE PROCESSOR INSTALL NEW OCCUPANCY WALL SWITCH WATTSTOPPER DSW-301B IN SAME LOCATION. ...... ............-..;......-..._f. ,. ..I i SINGLE ORBIT 5 I O4 CEEIOLING M. MOUNTED OCCUPANCY SENSOR WATTSTOPPER DT-355 IN STOCK ..E 41-I ""«.... 5 J-BOX FOR SPEAKER FLUSH MOUNTED IN CEILING. FIELD VERIFY LOCATION E i (1-4)SHOPPER TRAK DETAIL qi- 3 WITH PROJECT MANAGER. _..._. .._..W.....".W.__ _. _ SCALE' NOPE 6 ELECTRICAL CONTRACTOR TO CLEAN, RE-LAMP AS NECESSARY (AND <C' --•- LU._..._ RE-BALLAST IF NECESSARY) ALL EXISTING FIXTURES AS REQUIRED TO i • CC •ENSURE THAT ALL FIXTURES ARE FULLY FUNCTIONAL. REPLACE ANY BROKEN 01 ci GENERAL CONTRACTOR NOTES: LENSES. NEW LAMPS, LENSES AND BALLAST IF NECESSARY WILL BE 1— 1. THE ORBIT 5 UNIT WILL BE INSTALLED CENTERED ABOVE THE DOORWAY. THE DISTANCE SUPPLIED BY ELECTRICAL CONTRACTOR. �z 6""# cm ' IN FROM THE DOORWAY WILL VARY DEPENDING ON WHETHER OR NOT THERE IS A O IF NOT FOUND TO BE EXISTING, ELECTRICAL CONTRACTOR SHALL PROVIDE A 01 £3. - all DOOR THAT IS USED DURING THE DAY, AND WHICH DIRECTION THE DOOR SWINGS: MINIMUM 90 MINUTE EMERGENCY BALLAST FOR EXISTING LIGHT FIXTURE, ? Z .1-.4.1t- A. IF THERE IS NO DOOR AT THE DOORWAY, OR THE DOORS WILL BE PROPPED OPEN Q CO 5` - I DURING THE DAY THE ORBIT 5 WILL BE MOUNTED 6"-12" INSIDE OF THE DOORWAY. �� FIXTURE SCHEDULE �� SCHEDULE `_ : ',.. SEE ARCHITECTURAL FI G LG FOR MOUNTING B. IF THERE IS A DOOR THAT SWINGS OUT, THE ORBIT 5 WILL BE MOUNTED 12"-18" INSIDE " .. "" LOCATION. THE DOORWAY. QTY SYMBOL TYPE MANUFACTURER CATALOG N0. DESCRIPTION NOTES VOLTS REC SUR PEN WAL REF LAMP/ / LAMP/ FIXTURE MANUFACTURER/ ;� ...„. . ... .£., { C. IF THERE IS A DOOR THAT SWINGS IN, THE ORBIT 5 WILL BE MOUNTED 4"-6" IN FROM • THE FURTHEST IN-SWING OF THE DOOR. TURNING OFF SWITCH "b" 128 V C JUNO R541 BL BLACK TRACK HEAD 1 ,3,4 120 X 1 12 12 PHILIPS 12PAR30S/ WILL REDUCE LIGHTING PER END/F22/3000/410126 2. IF THE CEILING SOFFIT IS 15' A.F.F. OR LESS AT THE MOUNTING LOCATION SPECIFIED ABOVE, CODE. `� / IR DIRECTLY TO THE CEILING. FOR CEILING SOFFITS HIGHER THAN �+ 22 CA JUNO T2BL SINGLE CIRCUIT 1 120 X NOT APPLICABLE - ORBIT 5 WILL BE ATTACHED D E / 24 TRACK BLACK FINISH mm" " 15', SHOPPER TRAK WILL INSTALL A MOUNTING BRACKET THAT ATTACHES TO THE WALL a b c ABOVE THE DOOR THAT WILL SUPPORT THE ORBIT AND POSITION TH UNIT 6"-18" INTO THE ❑ GENERAL LTG SINGLE CIRCUIT f ' I STORE. THE MOUNTING BRACKET WILL GENERALLY BE INSTALLED AT 12" A.F.F., UNLESS Ell 2 • CB JUNO T4BL 48" TRACK BLACK FINISH 1 120 X NOT APPLICABLE CONSTRUCTION CONDITIONS PREVENT THIS. LP-1 1 LP--13I SALES GEN. SALES DISP. 2 i 1 CC JUNO T6BL SINGLE CIRCUIT 1 120 X NOT APPLICABLE of , 3. IF THE CEILING HEIGHT I5 GREATER THAN 15' A.F-F., AND THE UNIT CANNOT BE MOUNTED 72 TRACK BLACK FINISH P- J BELOW 15' USING A BRACKET ATTACHED TO THE WALL ABOVE THE DOOR BECAUSE OF A TRACK TRACK a; CONTINUOUS, MULLION-FREE GLAZING, OR AN OPENING THAT EXTENDS TO THE CEILING, LIGHTING LIGHTING 18 CD JUNO T8BL SINGLE CIRCUIT1 120 X NOT APPLICABLE wj CI_ AN ORBIT WITH A SPECIAL TELEPHOTO LENS WILL BE INSTALLED AT THE CEILING LEVEL. 96" TRACK BLACK FINISH THE TELEPHOTO LENS IS NOT EFFECTIVE ABOVE 30' A.F.F. SPRING WOUND MANUAL BYPASS' LIVE END POWER FEED • Z TIMER WITH 0-2 HOUR RANGE WITHOUT HOLD 28 - CE JUNO T38BL 1 120 X NOT APPLICABLE 4. IF THE STORE HAS A VESTIBULE, THE ORBIT WILL BE MOUNTED INSIDE OF THE STORE FEATURE FOR GENERAL LIGHTING CONTACTOR BLACK FINISH .^ ITSELF, RATHER THAN IN THE VESTIBULE. TORK# A502HWF-'" 1 1 CF JUNO T23BL CENTER "MINI-CONNECTOR" FEED 1 120 X NOT APPLICABLE _ 5. IF THE STORE WILL HAVE A HARD (PLASTER OR SHEETROCK) CEILING, INSTALL A CONTRACTOR TO VERIFY EXACT CONFIGURATION W a JUNCTION BOX 1 "-2" AWAY FROM THE RECOMMENDED ORBIT LOCATION SPECIFIED ABOVE. REQUIRED WITH SPACE AVAILABLE. PROVIDE 9 L CG JUNO T24BL ADJUSTABLE CONNECTOR 1 120 X NOT APPLICABLE a § J LABELS AS DIRECTED BY OWNER. SWITCHES 6. PROVIDE 1/2" CONDUIT W/PULL STRING FROM THE COMMUNICATIONS STRUCTURE TO A LOCATION SHALL NOT BE MOUNTED HIGHER THAN 48" m ABOVE ENTRY SOFFIT. LOOP CONDUIT TO OTHER DOORS AS REQUIRED. 6 0 Ni JUNO TC2-SP22538C-BL DOWNLIGHT WITH CLEAR 1 120 X 1 12 12 PHILIPS 12PAR3OS/ 0Q SWITCH BANK BLACK TRIM REFLECTOR F25 3000 AF SO-B 4 , W .._... . . U -+,,, o-_ N. COMMUNICATION WORK: NOM 2 ® X JUNG NXPB3RBLICC MIN BATTERY BACKUP EMERGENCY EXIT SIGN WITH 90 1 ,4,5 120 X 1 4 4 INCLUDED Q c):) m 0) 44 0 N a EMERGENCY WALL PACK WITH 90 z 1. FOR SINGLE ORBIT 5 INSTALLATIONS, A CATEGORY 5 CABLE MUST BE RUN FROM 7 �■Q XA JUNO N 1 BL 1 ,4,5 120 X X 2 5.4 11 INCLUDED r m € Q CO (-) -NLNI4sif • MIN BATTERY BACKUP F- �- THE STORE CONTROLLER/SP TO THE FRONT DOOR (MAIN CUSTOMER ENTRANCE). _ - _ _-... " Y `• ,� NOTE IF A STORE HAS MULTIPLE CONTROLLERS, PLEASE CALL SHOPPER TRAK OR THE 3 w N ' SWITCHES SHALL BE INSTALLED BETWEEN STUDS IN 1. FIXTURES AND LAMPS SUPPLIED BY TENANT AND INSTALLED BY ELECTRICAL CONTRACTOR UNLESS OTHERWISE NOTED. o z CLIENTS STORES SYSTEMS GROUP TO DETERMINE WHICH ONE WILL BE USED. ROWS OF (6) SIX. DO NOT CUT STUDS TO 2. EQUIP NEW FLUORESCENT LIGHT FIXTURES WITH ELECTRONIC BALLASTS. " t 2. PROVIDE 15'-20' OF CABLE COILED UP AT EACH END OF THE RUN. AT THE FRONT ACCOMODATE A SINGLE ROW OF SWITCHES. 3. FIXTURES SHOWN WITH CROSS-HATCH ARE TO BE NIGHT LIGHTS. "r TH CABLE COIL IN A LOCATION THAT CAN BE REACHED USING AN CONTRACTOR SHALL LABEL LIGHT SWITCHES 4. FIXTURES USED FOR EXIT, EMERGENCY, OR NIGHT LIGHTING TO BE ON LOCKOUT CIRCUIT.` DOOR DLEAVE E B ACCORDINGLY. ALL FACES AND BODIES TO BE BLACK. 5. ALL FIXTURES USED FOR EXIT, OR EMERGENCY LIGHTS TO HAVE 90 MINUTE BATTERY BACK UP. E2.0 8' LADDER. REFER TO SPECS FOR WHEN REUSING EXISTING PANELS, E.C. SHALL VERIFY THE CONDITION AND QUANTITY OF ALL EXISTING CIRCUIT BREAKERS. WHEN REUSING EXISTING PANELS, E.C. SHALL VERIFY THE CONDITION AND QUANTITY OF ALL EXISTING CIRCUIT BREAKERS. I :� - LP-25 TIMECLOCK AND CONTACTOR REPLACE DAMAGED BREAKERS WITH NEW. PROVIDE ANY ADDITIONAL OR BREAKERS OF DIFFERENT AMPERAGE OR POLE AS REPLACE DAMAGED BREAKERS WITH NEW. PROVIDE ANY ADDITIONAL OR BREAKERS OF DIFFERENT AMPERAGE OR POLE AS ' REQUIRED TO MEET THE END RESULT INDICATED IN THE PANEL SCHEDULE. NEW BREAKERS SHALL BE OF THE SAME MFG REQUIRED TO MEET THE END RESULT INDICATED IN THE PANEL SCHEDULE. NEW BREAKERS SHALL BE OF THE SAME MFG �N T/C AND CHARI4urtrarorICS OF THE EXISTING. THE SUBMISSION OF THE BID PROPOSALS SHALL BE CONSIDERED EVIDENCE THAT AND CHARA..rt.rtrsuICS OF THE EXISTING. THE SUBMISSION OF THE BID PROPOSALS SHALL BE CONSIDERED EVIDENCE THAT CIRCUIT BRKR DESCRIPTION 1 cn THE CONTRACTORS HAVE VISITED THE SITE. NO EXTRA PAYMENTS WILL BE ALLOWED TO THESE CONTRACTORS ON ACCOUNT THE CONTRACTORS HAVE VISITED THE SITE. NO EXTRA PAYMENTS WILL BE ALLOWED TO THESE CONTRACTORS ON ACCOUNT MPT . SIGN-STOREFRONT 1 LP-1 I 1 S . w OF EXTRA WORK MADE NECESSARY BY HIS FAILURE TO VISIT THE SITE. OF EXTRA WORK MADE NECESSARY BY HIS FAILURE TO VISIT THE SITE. -...`- .. 4,, Ny:... y •- I f U _. LTG-SHOW WINDOW I LP-5 i t I 12 S c� �� ...,_: + f ' 2inl PANELBOARD DESIGNATION R NEW INSTALL EXIST LOCATION RELOCATED EXIST PANELBOARD DESIGNATION 1LP* NEW INSTALL ___ EXIST LOCATION X RELOCATED EXIST ___ £ " Y y I---i\--- 1 REC-SHOW WINDOW I LP-3 t J l 3 • S z iii o N w _ 01208 VOLTS 3 PHASE 4 WIRE, SOLID NEU I RAL �_4MPERE BUS 100 AMPERE MAIN __-L� __ _12Q/208 VOLTS 3 PHASE 4 WIRE, SOLID NEUTRAL 100 AMPERE BUS _100_AMPERE MAIN ___ LUG __ f " � """" i""' "i" " I II 14 w �( X , 14. . #.• 111 I I TOP FED ^ BOTTOM FED __- FLUSH MID _ SURFACE MTD X TOP FED X BOTTOM FED ___ FLUSH MID ___ SURFACE MTD .1 • CKT DESCRIPTION WATTS LOAD WIRE BRKR o A B C o'BRKR WIRE LOAD: CKT CKT LOAD WIRE BRKR J BRKR WIRE LOAD CKT . t OVERRIDE TIMER. # TYPE SIZE SIZE a SIZE SIZE TYPE WATTS DESCRIPTION # # DESCRIPTION WATTS TYPE SIZE SIZE a� A B C a SIZE SIZE TYPE WATTS DESCRIPTION # ; SEE SWITCH BANK DETAIL TS 1 SPARE -- -- - 20 1 H -- 1 1 20 - - -- SPARE 2 1 SIGN-STOREFRONT 1200 L 12 20 1 -j 1380 1 1 20 12 R 180 REC-POS 1 2 'm»'"L ? 3 SPARE -- - -- 20 1 -- I 1 20 - - -- SPARE 4 3 REC-SHOW WINDOW 360 R 12 20 1 ' 540 I 1 20 12 R 180 REC-PDS 2 4i 1 0 b 5 SPARE --- - - 20 1 I --- I 1 1 20 SPARE 6 5 LTG-SHOW WINDOW 60 L 12 20 1 I 420 H 1 20 12 R 360 REC-POS UTILITY 6 ' -- - - _ LTG CONTACTOR 7 SPARE 20 1 --� -- I - -- B 8 7 REC-SHOW WINDOW TV 180 R 12 20 1 5592 I 3 60 4 H 5412 DUCT HEATER/VAV 8 £ J 9 WATER HEATER 1500 M 12 20 2 11500 1 1 20 - - -- SPARE 10 9 LTG SALES TRACK 780 L 12 15 1 6192 \ 5412 10 11 _ - 1500 11500 H1 20 - - -- SPARE - i 12 11 LTG-SALES TRACK EM/NL 853 L 12 15 1 6265 H �` 5412 12 �� /C 13 SPARE -- - - 20 1 -- 1 20 - - -- SPARE 14 13 REC-BACKWRAP/TV 540 R 12 20 1 540 - - -- BLANK 14 ' CIRCUIT BRKR DESCRIPTION I LTG-SALES TRACK LP-9 _ I I I 1 TO SWITCH BANK SWITCH ( 15 SPARE -- - - 20 1 -- 1 20 SPARE 16 15 REC--SECURITY 360 R 12 20 1 I 360 I - - I - M..,... BLANK 16 s.*...•"M ...I I _ _LP-11 I 2 TO SWITCH BANK SWITCH17 SPARE -- - 20 1 I -- 1-- tet, a 18 17 LTG-STOCK/RR/HALL/EM 300 L 12 20 1 ' 300 - _ - �- BLANK 18I LTG-SALES TRACK EM/NL I 1119 SPARE -- - - 20 1 I r s �"r3 ; _ _ .. . -.-�4c 3 • "- 1 I . .. ill 20 19 REC-SALES GENERAL LEFT 360 R 12 20 1 H 360 I-- BLANK 20 I SPARE ----H I I 21 REC SALES GENERAL RIGHT 540 R 12 20 1 I 540 - -- - - -- BLANK 22CI CC".. �"U- " I SPARE I 14 • -- 11500 11500 SUB TOTALS L = LTG OR SIGNAGE R = RECEPTACLE 23 REC-STOCK/RR/HVAC 540 R 12 20 1 540 I -: - - -- BLANK 24 a M = MISCELLANEOUS 25 TIMECLOCK/BUZZR 360 M 12 20 1 - 360 - •- -- - --- BLANK 26 V v?, CONNECTED LOAD 3000 = - -- Z...�.... ....» - H H.V.A.C. 27 PHONEBOARD/IT RACK 540 R 12 20 1 I 540 BLANK 28 .T1t1ECLOCK AND LIGHTING K = KITCHEN 29 REC-DESK 360 R 12 20 1 360 .....:7,],.:47,,,. f30ct ,o ,NOTE: ALL BREAKERS SHALL BE BOLT-ON, UNLESS OTHERWISE NOTED. IF NOT FOUND EXISTING, E.C. SHALL PROVIDE .L� CONTACTOR CONTROL DIAGRAM • - INDICATES THIS CIRCUIT TO RECIEVE HANDLE LOCK-ON CLIP ISOLATED GROUND BAR. II RECEPTACLE OR SIGNAGE R = REC ' 8232 8172 7885 SUB TOTALS _ ,rj _ SCH = H.V.A.C. ac I ILEA NONE CONNECTED LOAD 24289 M = MISCELLANEOUS PHASE BALANCE 4.2% K = KITCHEN .. ..m * - UNSWITCHED LEG TO FIXTURES REQUIRING 24HR. OPERATION. NOTE: ALL BREAKERS SHALL BE BOLT-ON, UNLESS OTHERWISE NOTED. IF NOT FOUND EXISTING, E.C. SHALL PROVIDE ELECTRIC SERVICE DEMAND - INDICATES THIS CIRCUIT TO RECIEVE HANDLE LOCK-ON CLIP ISOLATED GROUND BAR. ' DESCRIPTION TOTAL WATTS TOTAL WATTS - , TRACK (2)15A X 120V 3600 3600 --- „- "...__ '""ma all 1 25% CONTINUOUS LOAD 900 900 LIGHTING & SIGN LOAD 1560 1560 - ' 25% CONTINUOUS LOAD 390 390 3 RECEPTACLES 4860 4860 MISC. 360 360 =1' `" WATER HEATER 3000 3000 ,_„ 771. _ HVAC COOLING 2268 -- } HVAC HEATING - 16236 . 25% LARGEST MOTOR 288 288 DEMAND W/ A/C LOAD 17226w 47.9a , DEMAND W/ KIR LOAD 31194w 86.7a -.� _ ..............._.._... •SYMBOL LEGEND ,„..... .M .. ..m UNIPLEX RECEPTACLE (SINGLE) ' (b DUPLEX RECEPTACLE # i CMI DUPLEX FLOOR MOUNTED DUPLEX ISOLATED GROUND 'CD ROOF LINE - - "41- U DUPLEX FLOOR MTD ISO GRD I .... ;W —LEASE LINE" IF NOT FOUND EXISTING, E.C. SHALL PROVIDE DUPLEX SPECIAL LOCATION ;Q C _.r........._._ � MINIMUM 1 #8 ISOLATED GROUND. o QUADPLEX RECEPTACLE 0 CO 1 IIP ••:� QUADPLEX FLOOR MOUNTED E EXIST. QUADPLEX ISOLATED GROUND Z I- N AB0 E CEI TNG � �.. P•4-4 -_.... , SHOWN FOR !�� QUADPLEX FLOOR MTD ISO GRD °� Z ;9-I REF. ONLY 1 QUADPLEX SPECIAL LOCATION 0 i cg 0 i4401 EXIST. (MIN) EXIST- (MIN) ® SPECIAL VOLTAGE OR AMPERAGE ...mm Z »`Ia .,Z 1 1 4 3, 1 -1/4"C 4 #3, 1 --1/4"C � SPECIAL VOLTAGE OR AMPERAGE --��-._� -� �- --"� 1 8 GND 1 #8 GND II C13 Q 1 8 ISO GND MULTI-OUTLET PLUGMOLD l N ,1.E.. I- - /EXIST. (MIN) 0 = FIELD VERIFY EXACT V DUAL PORT OUTLET a) a_ Cf) / 4 #3, 1 -1/4,, METER REQUIREMENTS aa 1 #8 GND EXISTING V TELEPHONE OUTLET ,[ 1 w 1 DISTRIBUTION PANEL 0 JUNCTION BOX 1 } TIMECLOCK AND ® DATA OUTLET 1 1 CO W CONTACTOR PANEL PANEL EXISTING 100A.S., IOOA.F.(MIN) CIDOORBELL PUSHBUTTON LPLPL IN EXISTING LANDLORD 8' I o 120/208V 30, 4W ti QUADPLEX REC. FORDOORBELL ELEC. Sif_ TELEPHONE. VERIFY REFER TO REFER TO DISTRIBUTION EQUIPMENT /r DOORBELL LOW-VOLT TRANS U ( W EXACT LOCATION PANEL PANEL F LOW-VOLTAGE TRANSFORMER n 1 I U SCHEDULE SCHEDULE ❑-' DISCONNECT SWITCH CO 0 TELEPHONE BOARD i 0 FLOOR LINE ELECTRICAL PANEL - - - Q KVA TRANSFORMER WI eELECTRICAL ONE-LINE DIAGRAM T/c 24HR 7 DAY-TIME CLOCK . I l SCALE NONE $ WALL SWITCH \ I» ..»...s W EI WALL MTD OCCUPANCY SENSOR o 1 . ALL WIRE SHALL BE COPPER ONLY, THW, THWN, 3. ALL ELECTRICAL EQUIPMENT (PANELS, TRANSFORMER, 0 0 THHW, OR NEC APPROVED EQUAL OR BETTER. ALL LIGHTS, DEVICES, CONDUIT, WIRE, ETC.) NOT BEING CEILING OCCUPANCY SENSOR rn m a WIRING SHALL BE IN CONDUIT. WIRE AMPACITY BASED USED SHALL BE REMOVED FROM THE SITE. — a CIRCUIT HOME RUN om ON NEC 110-14c AND TABLE 310.15(B)16. DO NOT ABANDON IN PLACE. Z m o CO 'Vi CONDUIT THRU/BELOW FLOOR Z ; �, �'� 2. E.C. SHALL FURNISH ALL NEW ELECTRICAL EQUIP. 4. E.C. SHALL FIELD VERIFY ALL EXISTING ELECTRICAL o 3 ,�; !, CO:"PANELS, TRANSFORMER, CONDUITS, WIRE, METERS, EQUIPMENT. ALSO FIELD VERIFY THAT ANY EXISTING �- CONDUIT STUBBED UP/DOWN v t!" SERVICE FEEDERS AND CONDUIT, DISC SWITCHES, ELEC. EQUIPMENT TO BE REUSED IS OF ADEQUATE �" +,ra ~ CONTACTORS, TIMECLOCKS, ETC) AS REQUIRED, SIZE AND CONDITION TO MAINTAIN SAFE OPERATION. N.L. NIGHT LIGHT 0 UNLESS NOTED OTHERWISE. IF DISCREPANCIES ARISE CONTACT PROJECT REP. VIA T/C TIMECLOCK CONTROLLED CIRCUIT E 1_ GEMERAI_ BLIN1i Iiia CONDUIT RUNS EXCEEDING 100 FEET IN LENGTH OR HAVING IN EXCESS OF THREE 90 DEGREE TURNS SHALL BE PROVIDED WITH 13. T OF um PROVIDE SINGLE-PHASE AC FRACTIONAL HP MANUAL MOTOR STARTERS, OF SIZES AND RATINGS REQUIRED. EQUIP WITH MANUALLY , PULL BOXES. CONDUIT FILL SHALL NOT EXCEED 30 PERCENT. ALL CONDUIT SYSTEMS (INCLUDING J.B.'S, P.B.'S, ETC.) SHALL BE OPERATED QUICK-MAKE. QUICK-BREAK TOGGLE MECHANISMS; AND WITH ONE-PIECE MELTING ALLOY TYPE THERMAL UNITS. EQUIP THE GENERAL PROVISIONS OF THE CONTRACT INCLUDING ANY GENERAL AND SUPPLEMENTAL CONDITIONS AND GENERAL REQUIREMENTS PERMANENTLY IDENTIFIED- NEW BRANCH CIRCUIT HOME-RUN CONDUITS SHALL BE NO LARGER THAN 1-1/4" DIAMETERR. CONDUIT FILL PRIOR TO ROUGH-IN, VERIFY ALL BOX/DEVICE MOUNTING HEIGHTS AND LOCATIONS IN FIELD WITH OWNER'S REPRESENTATIVE RELATIVE WITH THERMAL OVERLOAD RELAY WITH FIELD ADJUSTMENT CAPABILITY OF PLUS OR MINUS 10% VARIATION OF NOMINAL OVERLOAD •_ APPLY TO THE WORK IN THIS SECTION. BEFORE SUBMITTING A BID, EXAMINE ALL MECHANICAL ARCHITECTURAL. AND/OR STRUCTURAL SHALL NOT EXCEED NEC REQUIREMENTS. TO EQUIPMENT BEING SERVED AND RELATIVE TO EXISTING CONDITIONS WHERE APPUCABLE. IN GENERAL, WHERE NOT LOCATED AT HEATER RATING. FOR PROTECTION OF FRACTIONAL HP MOTORS AS SHOWN ON DRAWINGS. STARTER SHALL BECOME INOPERATIVE WHEN ' - rY lir DOCUMENTS, VISIT THE SfTE AND GET ACQUAINTED WITH ALL CONDITIONS THAT MAY IN ANY WAY WHATSOEVER AFFECT THE EXECUTION COUNTER AREAS, THE HEIGHT OF BOXES FROM FINISHED FLOOR TO CENTER OF BOXES SHALL BE AS FOLLOWS, UNLESS OTHERWISE THERMAL UNIT IS REMOVED. PROVIDE STARTERS WITH DOUBLE BREAK SILVER ALLOY CONTACTS, VISIBLE FROM BOTH SIDES OF '� 4 OF THIS CONTRACT. TAKE MEASUREMENTS AND BE RESPONSIBLE FOR EXACT SIZE AND LOCATIONS OF ALL OPENINGS REQUIRED FOR CONDUIT SHALL BE CLEANED INSIDE BEFORE ANY WIRES ARE PULLED. CONDUIT ENDS SHALL BE CAPPED AND PLUGGED WITH NOTED ON PIANS: STARTER; GREEN PILOT LIGHTS, AND SWITCH CAPABLE OF BEING PADLOCKED-OFF. MANUAL STARTERS SHALL BE EQUAL TO THE 0) W •••- THE INSTALLATION OF WORK. FIGURED DIMENSIONS ARE REASONABLY ACCURATE AND SHOULD GOVERN IN SETTING OUT WORK. WHERE STANDARD ACCESSORIES AS SOON AS CONDUIT HAS BEEN PERMANENTLY INSTALLED. CONDUIT INSTALLED WITHOUT CONDUCTORS FOLLOWING. Z (D m a, DETAILED METHOD OF INSTALLATION IS NOT INDICATED OR WHERE VARIATIONS EXIST BETWEEJN DESCRIBED WORK MID APPROVED SHALL BE PROVIDED WITH SWEEP BENDS AND BALING WIRE FOR PULLING. SWITCHES 4'O" RECEPTACLES 1'3" 0 ' 0 PRACTICE, DIRECTION OF THE OWNER'S REPRESENTATIVE ON JOB SITE SHALL BE FOLLOWED. TELEPHONE OUTLETS (WALL PHONE) 4'0" TELEPHONE OUTLETS (DESK PHONE) 1'3" MANUAL STARTER IN FINISHED AREAS: - `• - AEL JOINTS SHALL BE MADE TIGHT WITH WATERTIGHT COUPLINGS MATCHING CONDUIT ANO ALL CORNERS SHALL BE MAKE WITH LONG FIRE ALARM MANUAL PULL STATIONS 4'0" DATA CABLE OUTLETS i'3" 0 far .:� THE CONTRACT INCLUDES ALL ITEMS OF MATERIAL AND LABOR REQUIRED FOR THE COMPLETE INSTALLATION AND FULL OPERATION OF RADIUS. THE ENDS OF ALL CONDUITS SHALL BE CUT SQUARE AND REAMED AND ALL JOINTS BROUGHT TO A SHOULDER. CONDUIT FIRE ALARM A/V ALARMS 6'8" SQUARE D #2510 FLUSH MOUNTED. 2-POLE TOGGLE SWITCH TYPE WITH NEON PILOT AND NEMA 1 TYPE B )C -P ,,, THE ELECTRICAL WORK AS SHOWN ON THE DRAWINGS AND HEREINAFTER SPECIFIED. ALL WORK, MATERIALS, AND EQUIPMENT SHALL SWILL BE CONTINUOUS BE WEEN OUTLETS TO MAKE A COMPLETE INSTALLATION AND TO EFFECT A CONTINUOUS GROUND. SUITABLE DEVICES AT SPECIAL HEIGHTS AS DIRECTED IN FIELD. ENCLOSURE FOR FLUSH WALL INSTALLATION. w d HAVE A ONE YEAR WARRANTY AFTER ACCEPTANCE OF THE WORK BY THE OWNER. ANY DEFECTIVE ITEMS SHALL BE REMOVED AND SUPPORTS MND FASTENING SHALL BE PROVIDED FOR CONDUIT. P s • MANUAL STARTER FOR EXPOSED CONDUIT INSTALLATION: IN R. N�.... REPLACED AT THE ELECTRICAL SUB CONTRACTOR'S IXPENSE AND TO THE SATISFACTION OF THE ENG EE 1AI. 1u�' YIl4 (`�� � CONDUIT SHALL BE SUPPORTED BY APPROVED STRAPS, FASTENERS AND HANGERS. HANGERS SHALL BE SUSPENDED FROM RODS. u1; 1 PERFORM WORK UNDER THIS CONTRACT IN CLOSE HARMONY WITH OTHER CONTRACTORS SO COMPLETED WORK SHALL PRESENT A PERFORATED STRAPS WILL NOT BE ACCEPTABLE. FASTENERS SHALL BE LEAD EXPANSION SHIELDS IN BLOCK OR CONCRETE, TOGGLE FURNISH AND INSTALL ALL NECESSARY CABLE OF THE SIZE AND TYPE INDICATED ON THE DRAWINGS OR SPECIFIED HEREINAFTER. ALL SQUARE D #8536 SURFACE MOUNTED, 2-POLE TOGGLE SWITCH TYPE WITH NEON PILOT AND NEMA 1 TYPE FG-2P - "X NEAT AND WORKMANLIKE INSTALLATION. EXPOSED FINISHED MATERIALS AND EQUIPMENT SHA1_ BE CAREFULLY CLEANED AND WIPED TO BOLTS IN HOLLOW WALLS, AAACHINE SCREWS ON METAL SURFACES AND WOOD SCREWS ON WOOD CONSTRUCTION. ALL CONDUIT SHALL WIRE SHALL BE COPPER. ALL WIRING SHALL BE NEW. NO WIRE SMALLER THAN #12 AWG SHALL BE INSTALLED UNLESS SPECIFICALLY ENCLOSURE FOR SURFACE WALL INSTALLATION. _ ... REMOVE GREASE, SMUDGES, DUST AND OTHER SPOTS AND LEFT SMOOTH AND CLEAN. DURING THE PROGRESS OF THE WORK, THE BE SUPPORTED INDEPENDENTLY FROM ALL OTHER BUILDING SYSTEMS AND SHALL BE SUPPORTED DIRECTLY FROM STRUCTURAL : . , DESIGNATED. USE OF #14 COLOR CODED WIRE WILL BE ALLOWED FOR CONTROL CIRCUITS ONLY. ALL WIRING SHALL BE IN CONDUIT ELECTRICAL SUB-CONTRACTOR SHALL CAREFULLY CLEAN UP AFTER HIS MEN AND SHALL LEAVE THHE PREMISES AND ALL PORTIONS OF COMPONENTS. UNLESS SPECIFICALLY INDICATED OTHERWISE HEREIN. ALL CONDUCTORS SHALL BE COPPER. PROVIDE STRANDED CONDUCTORS FOR FUSES; THE BUILDING IN WHICH HE IS WORKING FREE OF DEBRIS AND IN A CLEAN AND SAFE CONDITION. ALL SIZES UNLESS INDICATED OTHERWISE. - PROVIDE SLEEVES FOR ALL FIRE WALL AND SMOKE PARTITION PENETRATIONS (SEALED ACCORDINGLY). ALL RACEWAYS SHALL BE SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE FUSES OF ONE OF THE FOLLOWING. AL FUSES SHALL BE OF THE SAME TIGHTEN ELECTRICAL CONNECTORS AND TERMINALS, INCLUDING SCREWS AND BOLTS, IN ACCORDANCE WITH EQUIPMENT ENTIRELY FREE OF PLASTER. MORTAR, WATER AND OTHER FOREIGN MATTER. RACEWAYS INSTALLED UNDER THIS CONTRACT WITHOUT MANUFACTURER: HUSSMAN. UTTELFUSE. MJ MANUFACTURER'S PUBLISHED TORQUE TIGHTENING VALUES FOR EQUIPMENT CONNECTORS. WHERE MANUFACTURER'S TORQUING CONDUCTORS SHALL WAVE BALING WIRE LEFT IN RACEWAYS FROM OUTLET TO OUTLET FOR FUTURE PULLING OF CONDUCTORS. PROVIDE THHN/THWN INSULATION FOR ALL CONDUCTORS SIZE SDO MCM (KCMIL) AND LARGER, AND N0. 8 AWG AND SMALLER. FOR Ap s REQUIREMENTS ARE NOT INDICATED, TIGHTEN CONNECTORS AND TERMINALS TO COMPLY WITH TIGHTENING TORQUES SPECIFIED IN RACEWAYS OPEN ENDS SHALL BE PLUGGED OR CAPPED IN AN APPROVED MANNER. ALL OTHER SIZES PROVIDE THW OR THHN/THWN INSULATION AS APPROPRIATE FOR THE LOCATIONS WHERE INSTALLED. PROVIDE EXCEPT AS OTHERWISE INDICATED, PROVIDE FUSES OF TYPES, SIZES, RATINGS, AND AVERAGE TIME-CURRENT AND PEAK LET-THROUGH 0 V APPLICABLE UL AND NEC STANDARDS. COLOR CODED INSULATION/JACKET FOR PHASE IDENTIFICATION. ALL WIRES SHALL 8E RATED AT 600 VOLTS. CURRENT CHARACTERISTICS INDICATED, WHICH COMPLY WITH MANUFACTURER'S STANDARD DESIGN, MATERIALS. AND CONSTRUCTED IN M WHERE "FISHING" THROUGH EXISTING HOLLOW PARTITIONS IS MANDATORY, USE MINIMUM 3/4" "GREENFIELD" (STEEL) FOR LOW X W- ACCORDANCE WITH PUBLISHED PRODUCT INFORMATION, AND WITH INDUSTRY STANDARDS AVD CONFIGURATIONS. FUSES 1 AMPERE "`"""""""" WHENEVER THE WORDS "CONTRACTOR", "THIS CONTRACTOR", ETC. APPEAR ON DRAWINGS OR IN THESE SPECIFICATIONS FOR THE VOLTAGE CABLING AND METAL-CLAD/ARMORED CABL.E (U5TEO FOR USE IN HEALTH CARE FACILITIES) FOR POWER. OTHERWISE TYPE PROVIDE TYPE HH 2 INSULATION FOR ALL WIRING SUBJECT TO MUISTURE, FOR ALL WIRING BELOW GRADE AND FOR ALL WIRING THROUGH 600 AMPERES SHALL BE REJECTION TYPE. FUSES 601 AMPERES THROUGH 6000 AMPERES SHALL BE HI-CAP, BOLT TYPE. o I ELECTRICAL WORK, IT SHALL REFER TO THE ELECTRICAL SUB-CONTRACTOR. WHENEVER THE WORD "PROVIDE" APPEARS IN THESE MC/AC CABLE MAY ONLY BE USED FOR 6' FIXTURE WHIPS, UNLESS CASE-BY-CASE PERMISSION IS GRANTED BY ENGINEER AND FED FROM ISOLATED POWk=R SYSTEMS. OVN PROVIDE FACTORY FUSE IDENTIFICATION LABELS, INSTALLED ON THE INSIDE OF THE DOOR OF EACH SWITCH INDICATING TYPE AND DOCUMENTS, IT SHALL BE INTERPRETER TO MEAN "FURNISH & INSTALL". KEEP CONDUCTOR SPLICES TO MINIMUM. PULL CONDUCTORS SIMULTANEOUSLY WHERE MORE I AEN ONE IS BEING INSTALLED IN SAME SIZE OF FUSES INSTALLED. FOR TYPES AND RATINGS REQUIRED, FURNISH ADDITIONAL FUSES, AMOUNTING TO 10 PERCENT OF FUSES 0 J RACEWAY. USE UL LISTED PULLING COMPOUND OR LUBRICANT, WHERE NECESSARY. INSTALL SPLICE AND TAP CONNECTORS WHICH SUPPLIED, BUT NOT LESS THAN ONE SET OF 3 OF EACH KIND. OUTLET MOUNTING HEIGHTS AS INDICATED ON THE PLANS ARE APPROXIMATE TO BE USED FOR BIDDING PURPOSES ONLY. THE EXACT - POSSESS EQUIVALENT OR BETTER MECHANICAL STRENGTH AND INSULATION RATING THAN CONDUCTORS BEING SPUCED. USE SPUCE L MOUNTING HEIGHT OF OUTLETS SHALL BE DETERMINED IN THE FIELD WITH RELATION TO ARCHITECTURAL DETAILS AND EQUIPMENT AND TAP CONNECTORS WHICH ARE COMPATIBLE WITH CONDUCTOR MATERIAL. INCREASE WIRE SIZES PER NEC TO OFFSET VOLTAGE EACH FUSE SHALL BE CLEARLY FACTORY MARKED WITH CLASSIFICATION, CHARAcILRI�IIw, AMPERE RATINGS, VOLTAGE RATINGS, ETC. O BEING SERVED. IT SHALL BE THE RESPONSIBILITY OF THIS CONTRACTOR TO COORDINATE OUTLET LOCATION WITH EQUIPMENT. THE A GROUNDED CONDUCTOR (NEUTRAL) SHALL BE INSTALLED WITHIN EACH JBOX INTENDED FOR THE INSTALLATION OFA LIGHTING OWNER'S REPRESENTATIVE SHALL BE PERMITTED TO RELOCATE ANY OUTLET PRIOR TO INSTALLATION WITHIN A 15 FOOT UMIT AT NO CONTROL DEVICE (TOGGLE SWITCH, DIMMER, OCCUPANCY SENSOR, PHOTOCELL, ETC). CURRENT OR FUTURE DEVICES MAY REQUIRE DROP A5/IF REQUIRED. UNTIL SHALL NOT NT IS READ INOTA E E IN SWITCHES NOR SH SH L BY O I HEASAM IN NU CTUIPMENT UNTIL THE EQUIPMENT (+) ADDITIONAL CHARGE IN CONTRACT PRICE. ALL FASTENERS. HANGERS AND METHODS OF HANGING EXPOSED WORK IN FINISHES AREAS LINE-TO-NEUTRAL VOLTAGE TO OPERATE THE ELECTRONICS OF THE DEVICE IN STANDBY MODE. ELECTRONIC CONTROL DEVICES SHALL tis -. .- ppm UNTIL THE EQUIPMIIYT IS READY TO BE ENERGIZED. ALL FUSES SHALL BE OF THE SAME MANUFACTURER. CV SHALL BE SUBMITTED TO THE OWNER'S REPRESENTATIVE FOR APPROVAL BEFORE INSTALLATION. IF DURING CONSTRUCTION IF BECOMES NOT INTRODUCE CURRENT ON THE EQUIPMENT GROUNDING CONDUCTOR DURING NORMAL OPERATION. PRIOR TO INSTALLING FUSES FOR PROTECTION OF SPECIFIC EQUIPMENT, MOTORS, ETC., VERIFY RECOMMENDED FUSE SIZE/TYPE IN T APPARENT THAT CERTAIN MINOR CHANGES IN LAYOUT WILL EFFECT A NEATER JOB OR BETTER ARRANGEMENT. SUCH ALTERATIONS DEVICE COLORS: FIELD FROM RESPECTIVE EQUIPMENT MANUFACTURER. IF A CONFLICT IN FUSE SIZE/TYPE RESULTS BETWEEN MANUFACTURER'S V SHALL BE MADE AS PART OF THE CONTRACT. ENGINEER'S APPROVAL SHALL BE OBTAINED BEFORE MAKING SUCH CHANGES. TIS PREFERRED A SEPARATE NEUTRAL BE USED WHEN POSSIBLE. PER THE NEC, IF A NEUTRAL LS SHARED, ALL UNGROUNDED .. WORKMANSHIP TFIROUGHOUT SHALL CONFORM TO THE STANDARDS OF BEST PRACTICE. MARKS, DENTS OR FINISH SCRATCHES WILL CONDUCTORS OFA MULTIWIRE BRANCH CIRCUIT MUST BE SIMULTANEOUSLY DISCONNECTED TO REDUCE THE RISK OF SHOCK TO DEVICES SHALL BE WHITE UNLESS OTHERWISE SPECIFIED IN CONTRACT DOCUMENTS.. RECOMMENDATIONS AND ABOVE SPECIFICATIONS, CONTACT ENGINEER. PROVIDE AL REQUIRED FUSES UNDER BASE BID. INSTALL FUSES M PERSONNEL WORKING ON EQUIPMENT SUPPLIED BY A MULTIWIRE BRANCH CIRCUIT. FOR A SINGLE PHASE INSTALLATION, THE IN FUSED SWITCHES. — �} NOT BE PERMITTED ON ANY EXPOSED MATERIALS, FIXTURES OR FITTINGS. INSIDE OF PANELS & EWiPMENT BOXES SHALL BE LEFT .-� CLEAN SIMULTANEOUS DISCONNECTION CAN BE ACHIEVED BY TWO SINGLE POLE CIRCUIT BREAKERS WITH AN IDENTIFIED HANDLE TIE OR BY A SPECIFICATION GRADE RECEPTACLES: 2-POLE SWITCH OR CIRCUIT BREAKER. FOR A 3-PHASE INSTALLATION, A 3--POLE CIRCUIT BREAKER OR THREE SINGLE POLE CIRCUIT CONTACTORS & TIM[CLOGKS; BREAKERS WITH AN IDENTIFIED HANDLE TIE PROVIDES THE REQUIRED SIMULTANEOUS DISCONNECTION OF THE UNGROUNREQ i ( ) LIGHTING CONTACTORS SHALL BE EQUAL TO SQUARE D TYPE L SERIES FOR NON-MOTOR LOADS {L.E. FOR TUNGSTEN do BALLAST THE SYSTEM SHALL RING ENTIRELY FREE FROM GROUND WHEN 11 STED OUT IN THE PRESENCE DF THE OWNER'S REPRESENTATIVE. DUPLEX 120V RECEPTACLES SHALL BE EQUAL Tp LEVITON 5362 SERIES NEMA 5-20R . LL THIS CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROPER INSTRUCTION OF EACH SYSTEM TO THE SATISFACTION OF THE OWNER'S CONDUCTORS. WHERE FUSES ARE USED FOR BRANCH CIRCUIT OVERCURRENT PROTECTION, A 2-POLE OR 3-POLE SWITCH NS m REQUIRED. LIGHTING AND RESISTANCE HEATING LOADS), ELECTRICALLY OPERATED, ELECTRICALLY HELD, IN NEMA 1 ENCLOSURE, WITH 120V COIL, !� REPRESENTATIVE. UPON COMPLETION OF THE JOB, THIS CONTRACTOR SHALL FURNISH THE OWNER WITH A COMPLETE SET OF CONTROLLED DUPLE( 120V RECEPTACLES SHALL BE EQUAL TO LEVITON #5362-S2 SERIES (NEMA 5-20R) 2 THROUGH 12-POLE VERSIONS AND CHARACTERISTICS AS INDICATED ON DRAWINGS DR AS REQUIRED. DRY CONTACTS SHALL BE CC Q - OPERATING INSTRUCTIONS ON ALL ELECTRICAL SYSTEMS INSTALLED. NEATLY DRESS ALL WORK. INSTALL ALL WORK PARALLEL AND PERPENDICULAR TO SURFACES OR EXPOSED STRUCTURAL MEMBERS, RATED AT 30A, 208V OR 600V AS REQUIRES. VERIFY ALL COIL VOLTAGE RATINGS IN FIELD. U i THE ELECTRICAL CONTRACTOR SHALL CONSULT THE PLANS OE ALL OTHER TRADES IN ALL INSTANCES BEFORE INSTALLING HIS WORK AND FOLLOW SURFACE CONTOURS, WHERE POSSIBLE. KEEP CONDUCTOR SPLICES TO MINIMUM. INSTALL SPLICE AND TAP CONNECTORS GROUND FAULT CIRCUIT INTERRUPTER DUPLEX 120V RECEPTACLES SHALL BE EQUAL TO LEVITON #6899 SERIES (NEMA 5-2OR). 50 THAT HIS PIPING WILL NOT INTERFERE WITH THOSE BRANCHES. IN THE EVENT OF A CONFLICT, THIS CONTRACTOR SHALL REPORT WHICH POSSESS EQUIVALENT OR BETTER MECHANICAL STRENGTH AND INSULATION RATING THAN CONDUCTORS BEING SPLICED. USE BASIC MULTI-PURPOSE TIME CLOCK SHALL BE EQUAL TO INTERMATIC #1-103 24HR MECHANICAL DPST CONTROL OF LOADS UP TO Q SPLICE AND TAP CONNECTORS WHICH ARE COMPATIBLE WITH CONDUCTOR MATERIAL. ALL WIRES SHALL BE RUN CONTINUOUS FROM DUPLEX ISOLATED GROUND 120V RECEPTACLES SHALL BE EQUAL TO LEVITON #5362-IG. SINGLE ISOLATED GROUND 120V 40A WITH 1 TO 12 ON/OFF OPERATIONS EACH DAY. FOR ENERGY CODE COMPLIANCE OR PER LANDLORD CRITERIA, USE TORK R O MTI TO THE OWNERS ntrntat,.„ATIVE AT ONCE AND DO NO FURTHER WORK TO BE INSTATED UNTIL A SATISFACTORY ARRANGEMEJNT I5 RECEPTACLES SHALL BE EQUAL TO LEVITON 5361-IG NEMA 5-20R . ~ ""' DECIDED UPON. ANY WORK DONE, DR EQUIPMENT PLACED IN POSITION BY THIS CONTRACTOR, CRFAI7NG A CONFLICT IN VIOLATION OUTLET TO OUTLET/FIXTURE TO FIXTURE. INSULATION VALUE OF JOINTS TO BE 100% IN EXCESS OF WIRE. PROVIDE ADEQUATE ( ) OT5400B TIME CLOCK THAT SHALL BE PROGRAMMABLE 365 DAY, 24 HOUR WITH OVERRIDE CONTROLS. UNIT SHALL BE 4 CHANNEL. 0 fC 1 HEREOF, SHALL BE READJUSTED TO THE SATISFACTION OF THE OWNER'S REPRESENTATIVE AT THE EXPENSE OF TWE CONTRACTOR. LENGTH OF CONDUCTORS WITHIN ELECTRICAL ENCLOSURES AND TRAIN THE CONDUCTORS TO TERMINAL POINTS WITH NO EXCESS. PROVIDE ALL REQUIRED EXTERNAL CONTACTORS, RELAYS, ETC. TO RENDER THE CONTROL SYSTEMS FULLY OPERATIONAL. VERIFY ZONE (� BUNDLE MULTIPLE CONDUCTORS, WITH CONDUCTORS LARGER THAN NO 10 AWG CABLED IN INDIVIDUAL CIRCUITS. MAKE TERMINATIONS SPECIAL PURPOSE RECEPTACLES SHALL BE OF THE SIZE, TYPE AVD MANUFACTURER AS INDICATED ON THE PLANS OR A5 CONTROL REQUIREMENTS IN FIELD PRIOR TO ROUGH-IN. PROVIDE BATTERY BACKUP EXTENDED POWER CJARRYOVER. CUSTOM THE DECISION OF THE OWNER'S REPRESENTATIVE SHALL BE FINAL IN REGARD TO CHANGES DUE TO CONFLICTING CONDITIONS. SO THEME IS NO BARE CONDUCTOR AT THE TERMINAL. DETERMINED IN FIELD. PROGRAMMING SHALL BE CONFIGURED AS SPECIFIED BELOW. ^ 2- SHOP T1i1tA5 BRANCH SUBFEEDER CIRCUITS SHALL BE INSTALLED AS SHOWN ON THE FLOOR PLANS. WHERE OUTLETS ARE INDICATED BY LETTERS SWITCHES: OPERATING HOURS SHALL BE SET AS FOLLOWS: ,,, �..... ............. ON PLANS, THEY SHALL BE CONTROLLED BY CORRESPONDING SWITCHES. NO WIRE SIZE SMALLER THAN NO. 12 SHALL BE USED FOR 1. VERIFY WITH LANDLORD AND OWNER FOR EXACT SETTINGS THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS ONLY FOR ITEMS OF MATERIAL AND EQUIPMENT DIFFERENT THEN THOSE ALREADY ANY BRANCH CIRCUIT UNLESS OTHERWISE NOTED ON PLANS FOR CONTROL CIRCUITS. LARGER SIZES SHALL BE USED WHERE SINGLE POLI= 120/277 SWITCHES SHALL BE EQUAL TO LEVITON #1221-2 SERIES. PILOT LIGHT SWITCHES SHALL BE EQUAL TO £ CALLED FOR WITHIN THESE DRAWINGS FOR APPROVAL BY THE ENGINEER. THE CONTRACTOR IS NOT AUTHORIZED TO PURCHASE ANY 1221-PL MATERIAL UNTIL SUCH APPROVAL IS OBTAINED_ A MINIMUM OF SIX SEPARATE SETS OF DRAWINGS IS REQUIRED AND WILL BE SHAL R AND/OR INDICATED GN THE PLOWS. D IZENTES FE FI PANEL TO FIRST OUTLET DFA 15 QR 20 AMPERE BRANCH CIRCUIT PANEL80ARD5: _ ...mm .. ........... ..m.._... SHALL REQUIRE THE FOLLOWING MINIMUM WIRE SIZE TO THE FIRST OUTLET. i DISTRIBUTED AS FOLLOWS: 1 COPY FOR ENGINEER'S FILE; 1 COPY FOR ARCHITECT'S FILE; 2 COPIES FOR THE OWNER'S FILA=; 2 DOUBLE-POLE 120/277 SWITCHES SHALL BE EQUAL TO LEV1TON /1222-2 SERIES; PILOT LIGHT SWITCHES SHALL BE EQUAL TO SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE PANELBOARD PRODUCTS OF THE FOLLOWING (FOR EACH TYPE AND RATING COPIES FOR THE CONTRACTOR. SHOP DRAWINGS SHALL BE NEATLY BOUND IN A FLAT RING BINDER HAVING JOB NAME MND UP TO 100 FEET: #12 1222-PL OF PANELBOARD AND ENCLOSURE): SQUARE D COMPANY '--------- CONTRACTOR'S NAME ON COVER. A SINGLE SUBMISSION IS PREFERRED HAVING ALL ITEMS INCLUDED. LOOSE SHEET OR INCOMPLETE 100 TO 200 FEET: #10 SUBMITTALS WILL NOT BE ACCEPTED. ALL ITEMS OF MATERIAL TO BE SUPPLIED WHICH DO NOT REQUIRE SHOP DRAWING SUBMISSION MORE 1HAN 200 FEET: 6 3-WAY 120/277 SWITCHES SHALL BE EQUAL TO LEVITON #1223-2 SERIES; PILOT LIGHT SWITCHES SHALL BE EQUAL TO 1223-PL PANELS SHALL BE DEAD FRONT, SAEEIY TYPE, FURNISHED WITH BRANCH CIRCUIT PROTECTING DEVICES. EQUIPMENT GROUNDING BOX, SUCH AS CONDUIT, WIRE, BOXES, ETC., SHALL BE USTED AS SEPARATE MATERIAL SHOWING MANUFACTURER'S NAME MND CATALOG MAN BUS AND CABLE LUGS FACTORY ASSEMBLED. WITH ALL COMPONENTS IN PLACE, READY FOR INSTALLATION. CABINET SIZES ARE - "- NUMBER AND TYPE AND SHALL BE INCLUDED WITH SHOP DRAWINGS SUBMITTAL. ALL BRANCH CIRCUITS MORE THAN 200 FEET IN LENGTH SHALL BE MINIMUM NO. 10 TO THE LAST OUTLET. CONTROL CIRCUITS SHALL OCCUPANCY SENSOR DEVICES SHALL BE AS SPECIFIED IN CONTRACT DOCUMENTS. BASED UPON A 20" WIDE BY 6" DEEP PANEL UNLESS OTHERWISE NOTED. PANELBOARDS SHALL BE EQUIPPED WITH FLUSH TYPE BE NO. 14 EXCEPT FOR RUNS EXCEEDING 300 FEET WHERE THEY SHALL BE NO. 12. OUTLETS SHALL BE LOCATED APPROXIMATELY LOCK AND CATCH. ALL LOCKS SHALL BE KEYED ALIKE, AND TWO KEYS ARE TO BE SUPPLIED WITH EACH LOCK. AS SHOWN ON THE PLANS AND SHALL BE WIRED TO PROVIDE CONTROL OF OUTLETS INDICATED. ALL WIRES OF ANY ONE CIRCUIT WALL PLATES: ."�. - SHALL BE RUN IN THE SAME CONDUIT. PANELBOARDS SHALL BEAR UL LABELS FOR THEIR SPECIFIC APPUCATIONS. PANELBOARDS SHALL BE SUITABLE FOR SERVICE VOLTAGE TWO SETS OF MECHANICAL/ELECTRICAL DRAWINGS SHALL 8E PROVIDED AS RECORD DRAWINGS WHICH SHALL BE SEPARATE, CLEAN, PROVIDE WALLPLATES WITH ENGRAVED LEGENDS WHERE INDICATED ON DRAWINGS AND/OR WHERE REQUIRED PER ELECTRICAL WITH NUMBER OF BRANCH CIRCUITS OF CAPACITY SCHEDULED. UNLESS OTHERWISE INDICATED, PANELEIOARDS AND SECTIONS THEREOF, µ ,,,--- SEPIA REPRODUCIBLES RESERVED FOR THE PURPOSE OF SHOWING A COMPLETE PICTURE OF THE WORK AS ACTUALLY INSTALLED. ALL WIRES SHALL BE RUN CONTINUOUS FROM OUTLET TO OUTLET. INSULATION VALUE OF JOINTS TO BE 100% IN EXCESS OF WIRE. IDENTIFICATION SECTION. ALL DEVICE WALLPLATES SHALL BE STANDARD SIZE; "MIDWAY", "OVERSIZED' ("JUMBO") OR "EDCIRA DEEP" IF ANY, SHALL HAVE MAIN LUGS ONLY OF CAPACITY EQUAL TO, OR GREATER THAN, THE RATING OR SETTING OF THE OVER THE THESE DRAWINGS SHALL ALSO SERVE AS WORK PROGRESS REPORT SHEETS AND THE ELECTRICAL SUB-CONTRACTOR SHALL MAKE MECHANICAL WIRE SPLICERS SHALL BE SCOTCHLOCK INSULATED TYPE, T&B STAKON OR APPROVED EQUAL. THE CONDUCTORS WALLPLATES SHALL NOT BE ACCEPTABLE. CONSTRUCT WITH METAL SCREWS FOR SECURING PLATES TO DEVICES; SCREW HEADS CURRENT PROTECTIVE DEVICE NEXT BACK ON THE LINE. ALL CIRCUIT BREAKER PANELBOARD BUS ASSEMBLIES SHALL BE OF THE ANY NOTATIONS, NEAT AND LEGIBLE THEREON DAILY AS WORK PROCEEDS. THE DRAWINGS SHALL BE AVAILABLE FOR INSPECTION AT TERMINATING AT EACH WIRED OUTLET SHALL BE LEFT NOT LESS THAN 8" LONG AT THEIR OUTLET FITTINGS TO FACILITATE COLORED TO MATCH FINISH OF PLATES. WALLPLATES COLOR TO MATCH DEVICE, WITH BEVELED EDGES, EQUAL TO LEVITON DISTRIBUTED (SEQUENCE) BUSSING TYPE THROUGHOUT, SO THAT ANY 2 ADJACENT SINGLE POLE BREAKERS AND/OR SPACES SHALL ALL TIMES AND SHALL BE KEPT AT THE JOB AT A LOCATION DESIGNATED BY THE OWNER'S REPRESENTATIVE. AT THE COMPLETION OF INSTALLMENT OF DEVICES OF FIXTURES. FRICTION AND RUBBER TAPE CONFORM TO FEDERAL SPECIFICATIONS HH-T-11 AND COMMERCIAL SPECIFICATION GRADE NYLON UNLESS OTHERWISE SPECIFIED IN CONTRACT DOCUMENTS. BE REPLACEABLE BY A 2 POLE INTERNAL COMMON TRIP BREAKER, AND ANY 3 ADJACENT SINGLE POLE BREAKERS AND/OR SPACES THE WORK, THESE RECORD DRAWINGS SHALL BE SIGNED BY THE ELECTRICAL SUB--CONTRACTOR, DATED AND RETURNED TO THE HH-T-111. PLASTIC ELECTRICAL TAPE SHALL BE SCOTCH /33+ OR APPROVED EQUAL SHALL BE REPLACEABLE BY A 3 POLE INTERNAL COMMON TRIP BREAKER. 15 AMP THROUGH 70 AMP INCLUSIVE. WITHOUT DISTURBING OWNER'S REPRESENTATIVE. FINAL PAYMENT OF CONTRACT WILL NOT BE MADE UNTIL RECEIPT AND REVIEW OF SAD DRAWINGS. 1S- 91J . t pare C11T11•iG AM) PAT1CFWp ANY OTHER BREAKER. ALL PANELBOARDS SHALL BE UL LISTED AND LABELED FOR USE AS SERVICE ENTRANCE EQUIPMENT WHERE PROVIDE TWO NEATLY BOUND (WITH TABBED SECTIONS) COPIES OF MAINTENANCE AND INSTRUCTION BOOKS, PARTS UST PERTAINING TYPE MC CABLE SHALL BE FORMED FROM CONTINUOUS LENGTH OF SPIRALLY WOUND, INTERLOCKED ZINC-COATED OR GALVANIZED BEING USED AS SUCH. TO ALL EQUIPMENT FURNISHED. SUBMIT TO THE OWNER'S REPRESERNTATIVE FOR APPROVAL. FINAL PAYMENT WILL NOT BE MADE UNTIL (INSIDE & OUTSIDE) STRIP STEEL. AU_ CONDUCTORS SHALL BE RATED FOR 90 DEG. C. MINIMUM. PROVIDE WITH FULL PARITY SIZED THIS CONTRACTOR SHALL DO ALL CUTTING AND PATCHING REQUIRED FOR THE ADMISSION OF HIS WORK. ANY DAMAGE DONE BY THIS DRAWINGS FOR RECORD, MAINTENANCE AND INSTRUCTION MANUALS ARE DELIVERED TO THE OWNER'S REPRESENTATIVE. GREEN INSULATED EQUIPMENT GROUND CONDUCTOR. PROVIDE COMPATIBLE STEEL FITTINGS WITH INTEGRAL RED PLASTIC INSULATED CONTRACTOR TO THE BUILDING DURING THE PROGRESS OF HIS WORK SHALL BE MADE GOOD AT HIS OWN EXPENSE. ALL PATCHING DISTRIBUTION PANELS SHALL BE SQUARED I-UNE. THROAT BUSHINGS, COMPLIANT WITH NEC 350-5. CABLES SHALL BE 90 DEG. C. RATED WITH ALL COMPONENTS AND FITTINGS LISTED SHALL BE DONE BY A SKIlLEO CFRAFTSMAN IN THAT RESPECTIVE TRADE. IT SHALL BE THE RESPONSNBILiIY OF THIS CONTRACTOR TO 4 PFRIt115 ANL] RirJJLAlIII'1rILS FOR GROUNDING AND COMPLIANT WITH THE FOLLOWING. SUPERVISE THE INSTALLATION OF, AVD PAY FOR ALL ADDITIONAL MEMBERS, WOOD OR METAL AND LABOR WHICH MAY BE REQUIRED 46DY/277 VOLT HIGH VOLTAGE PANELS SHALL BE SQUARE 0 NF. „__ „•„• TO SUPPORT ANY TYPE OF PERMANENT OR TEMPORARY ELECTRICAL. APPARATUS EMPLOYED IN THE EXECUTION OF THIS CONTRACTOR'S - THE LATEST EDITION OF THE NATIONAL ELECTRIC CODE SHALL BE THE MINIMUM REQUIREMENT FOR ALL WORK. ALL ELECTRICAL A) UL ST0.4 AND UL STD. 83. WORK. 208Y/120V UGHTING AND APPLIANCE PANELBOARDS SHA L BE EQUAL TO SQUARE D N000 WITH BOLT-ON BRANCH BREAKERS. i MATERIALS USED IN THIS WORK ANO ALL WORKMANSHIP IND TESTS PERFORMED THEREIN, UNLESS SPECIFICALLY SPECIFIED SHALL b) ANSI E119 AND E814. SEAL ALL NEW FLOOR, CEILING, WALL, SLAB, ETC. PENETRATIONS TO MATCH OR EXCEED EXISTING NEW ASSEMBLY FIRE RATINGS. r CONFORM TO THE LATEST RULES AND REGULATIONS AND SPECIFICATIONS OF THE NATIONAL BOARD OF FIRE UNDERWRITERS, LOCAL c) NEC ARTICLES 250 AND 333. PROVIDE SLEEVE SEALS FOR ALL SLEEVES; PROVIDE SLEEVES FOR ALL PENETRATIONS. VERIFY REQUIREMENTS IN FIELD. ALL ALL BUSSING SHALL BE COPPER. CURRENT CARRYING CONTACT SURFACES SHALL BE SILVER OR ITN PLATED. MAIN BUSES AND € AND STATE CODES AND AUTHORITIES HAVING JURISDICTION AND UTIUTY COMPANY. EXAMINE THE DRAWINGS AND SPECIFICATIONS FOR CONNECTORS SHALL IRE HARD DRAWN COPPER OF 98% CONDUCTIVITY, WITH CURRENT CARRYING CAPACITY TO MAINTAIN ESTABLISHED COMPLIANCE WITH PREVAILING CODES, REGULATIONS AND ORDINANCES AND BASE BID AND WORK ACCORDINGLY. ANY MINOR TYPE MC CABLE MAY BE UTILIZED ONLY IF NEC APPROVED AND IF APPROVED BY LOCAL AUTHORITY HAVING JURISDICTION AND IF PENETRATIONS dF FIRE-ELATED OR SMOKE-RATED WALLS, FLOORS, CEILINGS, ETC. SHALL BE SEALED IMMEDIATELY AFTER RACEWAYS RISE TESTS AS DEFINED IN UL STANDARD UL 67. , - DISCREPANCY BETWEEN THESE DRAWINGS/SPECIFICATIONS AND CODES, LAWS, ORDINANCES, RULES AND REGULATIONS SHALL BE INCLUDED IN THE LIMITED APPLICATIONS DEFINED BELOW. ARE INSTALLED. ALL NEW ELECTRICALLY RELATED WORK SHALL BE SUPPORTED DIRECTLY FROM BUILDING STRUCTURAL MEMBERS. NEW '. ELECTRICALLY RELATED WORK SHALL NOT BE SUPPORTED FROM DUCTWORK, DUCTWORK HANGERS, CEILING SUPPORTS, EXISTING ALL BRANCH CIRCUIT BREAKERS SHALL BE FULL AMBIENT COMPENSATED THERMAL MAGNETIC MOLDED CASE WITH QUICK-MAKE AND I BE BRulSIH BY THIS CONTRACTOR AS REQUIRED WITHOUT ANY ADDITIONAL REIMBURSEMENT. MAJOR DISCREPANCIES SHALL IMMEDIATELY CONDUIT SUPPORTS, ETC. ALL CONDUITS (AND CABLE ASSEMBLIES, WHERE APPUCABLE) SHALL BE ROUTED PARALLEL TO BUILDING QUICK-BREAK ACTION AND POSITIVE HANDLE TRIP INDICATION, BOTH ON MANUAL AND ON AUTOMATIC OPERATION. BREAKERS SHALL �-'--`�”' ”" """ """ --'- BE BROUGHT TO THE ATTENTION OF THE ENGINEER (IN WRITING), PRIOR TO INSTALLATION, ALONG WITH THE CONTRACTOR'S PROPOSED 1) ALL NEW i5 OR 20 AMPERE BRANCH CIRCUIT WORK. THIS SHALL APPLY ONLY UNDER ALL OF THE FOLLOWING CNRCUMfSTANGES STRUCTURAL MEMBERS. ANY AND ALL NONCOMPLIANT WORK INSTALLED BY THE ELECTRICAL CONTRACTOR SHALL BE REMOVED AND BE OF THE OVER-THE-CENTER TOGGLE OPERATING TYPE WITH THE HANDLE GOING TOA POSITION BETWEEN "ON- AND "OFF" TO COST FOR . 1. THIS CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS OR CERTIFICATES OF INSPECTION AND MID CONDITIONS. REINSTALLED TO THE SATISFACTION OF THE OWNER'S REPRESENTATIVE AND THE ENGINEER. AT THE EXPENSE OF THE ELECTRICAL INDICATE AUTdIAMATIG TRIPPING. _ APPROVAL REQUIRED FOR THIS BRANCH OF THE WORK. OWNER SHALL BE FURNISHED WITH CERTIFICATES OF FINAL INSI=ECTION ANO APPROVAL PRIOR TO FINAL ACCEPTANCE OF THIS BRANCH OF THE WORK. CONTRACTOR. -"- - a) ONLY WHERE CONCEALED (ALL EXPOSED WIRING SHALL BE INSTALLED IN CONDUIT). 1i ORAYIiIIt� AI110 TIp1LS 17_ Ll BREAKERS SHALL HAVE INTERNAL COMMONZTRIP WITH ALL LOAD SIDE BO L GS OF ONETBREAKERAIN�THEASAMEUGUTTER. ALL —� b) ROUTE ALL CABLES PERPENDICULAR AND PARALLEL TO THE BUILDING ARCHITECTURAL LINES/SURFACES/STRUCTURAL MEMBERS, KEEPING 4FF5ETS TO A MINIMUM AND FOLLOWING SURFACE CONTOURS WHERE POSSIBLE. MINION A UNIFORM ELEVATION FOR ALL ALL SURFACE MOUNTED BALLASII FIXTURES SHALL BE MOUNTED WIfH AR SPACES BETWEEN FIXTURE AND SURFACE PER LATEST CIRCUIT BREAKERS SHALL HAVE SEALED CASES TO PREVENT TAMPERING. ALL 15 AND 20 AMPERE BRANCH CIRCUIT BREAKERS SHALL THE SPECIFICATIONS AND ACCOMPANYING DRAWINGS ARE INTENDED TO DESCRIBE THE SCOPE OF ALL ELECTRIC/MECHANICAL WORK_ CABLL RUNS WHEREVER POSSIBLE. All CABLES SHALL BE SUPPORTED/ANCHORED AT MAXIMUM 4 FOOT INTERVALS AND WITHIN 12" BE UL LISTED AS SWD (SWITCHING DUTY). ALL 15-70 AMPERE BRANCH CIRCUIT BREAKERS SHALL BE HACK TYPE. ALL GFI CIRCUIT THE DRAWINGS ARE AN OUTLINE TO INDICATE THE APPROXIMATE LOCATION AND ARRANGEMENT OF RACEWAYS, WIRING AND EQUIPMENT. FASTENED EDITION OF NEPA/NEC. ALL RECESSED FIXTURES SHALL BE EQUIPPED WITH NECESSARY PLASTER FRAMES AND SURFACE TRIM. ALL BREAKERS SHALL BE uL CLASS A WITH MAXIMUM THRESHOLD OE 5 MA ALL BRANCH CIRCUIT BREAKERS SERVING ALL BALLASTED OF BOX OR OUTLET AND SHALL NOT SAG. INSTALL CABLES IN A MANNER THAT PREVENTS OVERHEATING CABLES SHALL BE THE DRAWINGS SHALL BE FOLLOWED AS CLOSELY AS POSSIBLE 1N EXECUTING OF THE WORK. SHOULD THERE BE A CONFLICT RECESSED FLUORESCENT FIXTURES SHALL BE EQUIPPED AND SUITABLY CONSTRUCTED TO OPERATE WITH "P" RATED BALLASTS. ALL (FLUORESCENT/HID) LIGHTING LOADS SHALL BE HID RATED. PROVIDE 20 (+/-) NON-PADLOCK TYPE BREAKER LOCK-ON DEVICES DIRECTLY TO THE STRUCTURE USING FACTORY CLAMPS/CUPS SPECIFICALLY DESIGNED FOR THE RESPECTIVE CABLE (CADDY OR BETWEEN DRAWINGS AND SPECIFICATIONS, THIS CONTRACTOR SHALL REFER THE MATTER TO THE OWNER'S REPRESENTATIVE FORA EQUAL) RECESS MOUNTED INCANDESCENT AND H.I.D. FIXTURES SHALL HAVE UL APPROVED THERMAL PROTECTION PER LATEST EDITION OF AND INSTALL ON BRANCH BREAKERS AS DIRECTED IN FIE=LD (NIGHT LIGHTS, COMPUTERS, SECURITY, ETC.). PROVIDE DETAILED DECISION AS TO METHOD OR MATERIAL. ELECTRICAL CONTRACTOR SHALL REFER TO DRAWINGS OF ALL OTHER TRADES FOR DETAILS, NE-PA/NEC. ALL JUNCTION BOXES AND SERVICEABLE COMPONENTS (BALLASTS, THERMAL PROTECTION DEVICES, FUSES, ETC.) FOR TYPEWRITTEN SCHEDULES FOR ALL PANELBOARDS. CIRCUIT BREAKERS SHALL BE FURNISHED AS SCHEDULED ON THE DRAWINGS OR l" 7 DIMENSIONS AND LOCATIONS OF OTHER WORK AND ROUTE HIS WORK SO AS NOT TO CONFLICT WITH ANY OTHER BRANCH. THIS RECESSED FIXTURES SHALL BE READILY ACCESSIBLE FOR SERVICE OR REPLACEMENT FROM BELOW THE CEIUNG, WITHOUT REMOVING AS OTHERWISE REQUIRES) BASED ON FIELD DETERMINATIONS. I CONTRACTOR SHALL BE RESPONSIBLE FOR CHECKING QUANTITIES OF EQUIPMENT MENTIONED IN THE SPECIFICATIONS WITH THOSE c) ONLY WHERE INSTALLED FOR NORMAL UTILITY CIRCUITS; ALL WIRING FOR EMERGENCY SYSTEM FEEDERS AND RECEPTACLE ANY CEILING COMPONENTS (OTHER THAN TILES). SHOWN ON THE DRAWINGS. IF DISCREPANCIES ARE NOTED, PROVIDE THE GREATER OF THE QUANTITIES OR THE BETTER OF THE BRANCH CIRCUITS SHAH. BE IN CONDUIT (EMT), NO EXCEPTIONS. PROVIDE ALL ELECTRICAL DISTRIBUTION RELATED EQUIPMENT WITH APPROPRIATELY BRACED BUSSING AND PROPERLY RATED BREAKERS, - �_ �• _ QUALITIES AS APPLICABLE. WHERE PLASTER FRAMES ARE INFERRED FOR UGHTING FIXTURES (EITHER BY NARRATIVE OR BY CATALOG NUMBER OR BY FUSES, ETC. FOR THE AVAILABLE FAULT CURRENTS. 1t POLITY SYSTfl APPLICATION) THE ACTUAL FUNCTION SHALL BE TAKEN TO MEAN FOR MOUNTING WITHIN GYPSUM BOARD OR SIMILAR TYPE CEILING ....._..._..._.._...,_............ , MA1E L5 EMU GENERA SYSTEM (I.E. NOT WITHIN WET PLASTER CEILING SYSTEM). IN EXISTING BUILDINGS WHERE FAULT CURRENT VALUES ARE NOT INDICATED ON DRAWINGS, COORDINATE WITH EXISTING "UPSTREAM" DISTRIBUTION EQUIPMENT PROVIDE EQUIPMENT AIC RATINGS TO MEET OR EXCEED SAME. ALL MATEJRIALS AND EQUIPMENT SHALL BE NEW. ALL MATERIALS, APPARATUS AND EQUIPMENT SHALL BEAR THE UNDERWRITER'S ALL LIGHTING FIXTURES UTILIZED FOR EMERGENCY EGRESS LIGHTING SHALL BE CONNECTED AHEAD OF SWITCHING. ALL BALLASTS OF LABORATORIES INC., LABEL WHERE REGULARLY 5UPPUED. CERTAIN MANUFACTURERS OF MATERIAL AND EQUIPMENT ARE SPECIFIED AND VOICE AND DATA CABLES SHALL BE INSTALLED IN "J-HOOK" STYLI= PATHWAY WHERE INDICATED ON DRAWINGS. ALL OTHER THE SAME TYPE SHALL BE OF THE SAME MANUFACTURER AND CATALOG NUMBER. ALL LAMPS OF THE SAME TYPE SHALL BE OF THE FILL OUT PANELBOARD'S CIRCUIT DIRECTORY CARD UPON COMPLETION OF INSTALLATION WORK. - . ._.s SHALL BE NEATLY U PLANS ARE DETAILED ACCORDING TO THIS MATERIAL. THIS CONTRACTOR SHALL BASE HIS BID ON FURNISHING AND INSTAWNG THIS WIRING/CABLES OF VOICE/DATA SYSTEMS AND ALL OTHER SYSTEMS SHALL BE INSTALLED IN CONDUIT, 3/4" MINIMUM. VERIFY ROUTE SAME MANUFACTURER AND CATALOG NUMBER. TYPEWRITTEN. ALL PANELBOARD Di,',..,.r.,ta SHALL INCLUDE THE ACTUAL ROOM NAMES/NUMBERS THAT ARE SELECTED FOR INTERIOR � MAKE OF MATERIAL AND EQUIPMENT. WHERE MORE THAN ONE MAKE OF MATERIA_ OR EQUIPMENT IS SPECIFIED, THE CONTRACTOR FOR "J-HOOK" WORK ABOVE CEILING IN FIELD IN ADVANCE WITH OWNER. SIGNAGE/DESIGNATION ""�"""`-""", SHALL STATE IN HIS BID WHICH MAKE HE •. • ..•_,a TO FURNISH. PROVIDE LOW ENERGY SOLID STATE RAPID START ELECTRONIC FLUORESCENT LAMP BALLASTS (LESS THAN OR EQUAL TO 20% TND) r` PROVIDE OUTLET BOXES AND CONDUIT STUBS FOR SYSTEMS AS INDICATED ON DRAWINGS. CONDUIT STUBS SHALL BE TURNED OUT IN SPECIFICALLY DESIGNED FOR OPERATING LAMP TYPES INDICATED. FLUORESCENT BALLASTS SHALL BE MOTOROLA OR ADVANCE EQUAL. JRANSFORMERS; ^ 7_ JOIST SPACE AND, WHERE LOCATED IN AREAS WfTH DRYWALL CEILINGS, SHAM BE EXTENDED TO THE NEAREST AREA WITH NO CEILING `i/ OR WITH ACOUSTICAL TILE CEILING. PROVIDE CONDUIT, BRIDLE RINGS AND RACEWAYS AS REQUIRED. ALL CONDUITS 5FW1 8E ALL FIXTURES SHOWN ON DRAWINGS WITH MULTI-LEVEL SWITCHING SHALL BE PROVIDED WITH MULTIPLE BALLASTS TO ACCOMMODATE POWER DISTRIBUTION 1RANSFORMERS SHALL BE SQUARE D DRY TYPE WITH COPPER WINDINGS. NH♦• PROVIDE MANUFACTURER'S STANDARD SELF-ADHESIVE VINYL TAPE NOT LESS THAN 3 MILS THICK BY 1-1/2" WIDE. WHERE PROVIDED WITH SWEEP "L" 90'S AND INSULATED THROAT FITTINGS (OR BUSHINGS). SAME. ALL OTHER FIXTURES MAY CONTAIN EITHER SINGLE BALLASTS OR MULTIPLE BALLASTS AS REQUIRED TO FULFILL REQUIRED PROVIDE 4" HIGH CONCRETE HOUSEKEEPING PAD (WITH CHAMFERED EDGES) FOR ALL FLOOR MOUNTED TRANSFORMERS. INSTALL APPLICABLE, INSTALL ON ALL CONCEALED RACEWAYS AT CONNECTION TO ALL JUNCTION BOXES, PULL BOXES, EQUIPMENT, FUNCTION AND AS REQUIRED TO COMPLY WITH CONSTRUCTION SCHEDULE=. UNITS ON VIBRATION MOUNTS; COMPLY WITH MANUFACTURER'S INDICATED INSTALLATION METHOD. i WALL/FLOOR/, ETC. UNLESS OTHERWISE INDICATED OR REQUIRED BY GOVERNING REGULATIONS, PROVIDE ORANGE TAPE WITH BLACK TYPICAL OUTLETS SHALL CONSIST OF A FLUSH WALL MOUNTED 4" SQUARE X 2-1/8" DEEP BOX WITH A DOUBLE GANG PLASTER L.t1itRS. RING. MAXIMUM CONDUIT FILL FOR NEW WORK SHALL BE 40%, BASED ON MANUFACTURE'S PUBLISHED DATA OF CABLE OUTSIDE INCANDESCENT LAMPS SHALL BE SYLVANIA OR PHILIPS, LONG LIFE TYPE (3000 HOURS). ALL INCANDESCENT LAMPS SHALL BE INSIDE DRY-TYPE TRANSFORMERS SHALL BE OF THE ENCLOSED VENTILATED TYPE WITH KVA AND VOLTAGE RATING AS CALLED FOR ON THE DIAMETER. FROSTED UNLESS SPECIFICALLY DIRECTED OTHERWISE. PROVIDE SOCKET ADAPTERS/EXTENDERS IF REQUIRED FOR ACCOMMODATING THE DRAWINGS AND WITH 150' CLASS H INSULATION AND MINIMUM OF SIX STANDARD FULL CAPACITY TAPS. SOUND LEVEL SHALL BE LOW ; CC PROVIDE CIRCUIT IDENTIFICATION BANDS FOR ALL CABLES AND CONDUCTORS. PROVIDE MANUFACTURER'S STANDARD COLOR CODING SPECIFIED LAMP. AND INSTALLATION SHALL INCLUDE KORFUND OR EQUAL VIBRATION DAMPENING MOUNTS AND FL XIBLE S1 LEL CONDUIT FOR PRIMARY FOR CABLE/CONDUCTOR JACKET AND/OR INSULATION FOR ALL CABLES AND CONDUCTORS OF ALL SYSTEMS. MATCH IDENTIFICATION CABLE, TERMINATION5, JACKS, LABEUNG, HARDWARE, SHALL BE PROVIDED BY A CERTIFIED COMMUNICATION TECHNOLOGY CONTRACTOR. AND SECONDARY. LOCATE TRANSFORMER AS NOT TO CAUSE SERVICING OR CLEARANCE DIFFICULTIES OF VIOLATIONS WITH OTHER �"-'"'"-'"`- WITH MARKING SYSTEM USED 1N EXISTING SYSTEMS (WHERE APPLICABLE), SHOP DRAWINGS, CONTRACT DOCUMENTS, AND SIMILAR CABLING SYSTEM SHALL BE PROVIDED AS REQUIRED FORA TURNKEY, COMPLETE WORKING SYSTEMS. FLUORESCENT LAMP COLOR TEMPERATURE SHA„L. BE 3500K (VERIFY). EQUIPMENT. PREVIOUSLY ESTABLISHED IDENTIFICATION FOR PROJECT'S ELECTRICAL WORK. PROVIDE ON ALLL CONDUCTORS OF ALL SYSTEMS. DELERMINE EXACT LOCA110N5 OF COMMUNICATION TECHNOLOGY EQUIPMENT, EQUIPMENT OUTLIES, ETC. IN FIF1D. USE CAL1T10N NUT COMPACT FLUORESCENT TWIN TUBE/DUAL TWIN TUBE LAMPS SHALL BE OSRAM OR PHILIPS, 82 CRI, MINIMUM 10,000 HOURS RATED. 20, k ALIWY ASI F BEgmeE1D' TO EXCEED THE ALLOWED BENDING RADIUS FOR RESPECTIVE CABLES AND NOT TO COMPROMISE THE INTEGRITY OF THE CABLES i CV INSTAL. ENGRAVE❑ PLASTIC-LAMINATE SIGN ON MAJOR UNITS OF ELECTRICAL EQUIPMENT, INCLUDING CENTRAL OR M/LSTER UNIT OF LONG FLUORESCENT TWIN TUBE LAMPS SHA1 BE OSRAM OR PHWPS, 82 CRI, 3150 {NITUL LUMENS, MINIMUM 20,000 HOURS RATED. EACH ELECTRICAL SYSTEM INCLUDING COMMUNICATION/CONTROL/SIGNAL SYSTEMS, UNLESS UNIT IS SPECIFIED WITH ITS OWN DURING INSTALLATION BY PULLING TIE-WRAPS TOO TIGHTLY, DAMAGING CABLES, ETC. RACEWAY/CABLING BEINDING RADII SHALL BE IT SHALL BE THE RESPONSIBILITY OF THE FIRE ALARM SYSTEMS CONTRACTOR TO DESIGN AND INSTALL A COMPLETE SYSTEM AS ~ SELF-EXPLANATORY IDENTIFICATION OR SIGNAL SYSTEM. EXCEPT AS OTHERWISE INDICATED, PROVIDE SINGLE UNE OF TEXT, 1/2" HIGH MINIMUM A5 DIRECTED ERY CABLE MANUFACTURER. USE PUWNG COMPOUND OR LUBRICANT, WHERE NECESSARY; COMPOUND MUST F32T8 FLUORESCENT LAMPS SHALL BE RAPID START, ENERGY SAVING TYPE, MINIMUM 75 GRI, MINIMUM 2850 INITIAL LUMENS AND REQUIRED. THE FIRE ALARM SYSTEMS CONTRACTOR SHALL OBTAIN ALL REQUIRED APPROVALS AND PERMITS FROM THE STATE FIRE 0 �� NOT DETERIORATE CONDUCTOR OR INSULATION. NEATLY DRESS ALL CABLE WORK. WORK SHALL BE INSTALLED IN A MANNER WHICH 0 Z r� LEIItRING, ON 1-1/2" HIGH SIGN (2' HIGH WHERE 2 LINES ARE REQUIRED), WHITE LETTERING IN BLACK FIELD. UNLESS DETERMINED MINIMUM 20,000 HOURS RATED. LAMPS SHALL BE SYLVANIA. °SRAM OR PHILIPS, EQUAL TO SYLVANIA #F032/RS. MARSHALL'S OFFICE AND LOCAL AUTHORITY HAVING JURISDICTION FOR APPROVAL. OTHERWISE IN FIELD, PROVIDE TEXT MATCHING TERMINOLOGY AND NUMBERING OF THE CONTRACT DOCUMENTS AND SHOP DRAWINGS. RESULTS IN MAINTAINING A MINIMUM DISTANCE OF 24 INCHES FROM FEEDER/BRANCH CIRCUIT RACEWAYS MND FROM ANY BALLASTED � _ cc, _._......._1� SECURE TO SUBSTRATE WITH FASTENERS, EXCEPT USE ADHESIVE WHERE FASTENERS SHOULD NOT OR CANNOT PE7NETRATE SUBSTRATE. LIGHTING FIXTURE. All SURFACE AND RECESSED CEILING FIXTURES INSTALLED ON GRID OR TILE CEIUNGS SHALL BE INSTALLED TO AGREE WITH MODULE FOR THE PURPOSE OF TRADE COORDINATION, THE FIRE ALARM SYSTEM CONTRACTOR SHALL PROVIDE TO THE ELECTRICAL CONTRACTOR UJ C7 j AS A MINIMUM PROVIDE SIGNS FOR EACH UNIT OF THE FOLLOWING CATEGORIES OF ELECTRICAL WORK WHERE SUCH WORK EXISTS ON OF CEILING EITHER DISPLACING A TILE, OR UNIT ON CENTER OF TILE, OR CENTERED ON GRID LINES. A COMPLETE SET OF PLAN DRAWINGS. Q -1 PROVIDE COLOR CODED JACKETS TO IDENTIFY RUNS OF DIFFERENT SYSTEMS. NEATLY ROUTE CABLES PARALLEL AND PERPENDICULAR THE PROJECT ALL STARTERS AND DISCONNECTS; ALL REMOTE FIXTURE OR EQUIPMENT SWITCHING DEVICES (VIA ENGRAVED D `"' ` l CABINETS - ANY OTHER E UIPMENT TO BUILDING ARCHITECTURAL LINES. GROUP CABLES BY SYSTEM TYPE WHEREVER POSSIBLE. VERIFY EXACT LOCATIONS OF TELEPHONE PROVIDE FIXTURES AND/OR FIXTURE OUTLET BOXES WITH HANGERS TO PROPERLY SUPPORT FIXTURE WEIGHT. ALL LIGHTING FIXTURES FIRE ALARM SYSTEM DEVICES (SMOKE DETECTORS, PULL STATIONS, BELLS, STROBES, ETC.) SHALL BE OF THE SAME MANUFACTURER Z W DESIGNATES); ALL SYSTEM DEVICES, PORTS, TAPS, J.B.'S, P.B.S, ETC.; PANELBOARDS, ELECTRGAL Q SWITCH, DATA SERVER(S), HEAD-END EQUIPMENT, EQUIPMENT OUTLETS, ETC. IN FIELD. INSTALLED IN OR ON SUSPENDED CEILING SYSTEMS SHALL BE ANCHORED DIRECTLY TO THE BUILDING STRUCTURAL SYSTEM ABOVE AS, AND COMPATIBLE WITH, THE EXISTING BUILDING FIRE ALARM SYSTEM. PROVIDE AUXILIARY CONTACTS lF REQUIRED FOR SPECIAL T DESIGNATED BY OWNER OR ENGINEER IN FIELD. 2. Q REVIEW ALL TERMINAT1dN AND LABELING REQUIREMENTS WITH OWNER IN ADVANCE. AL1 CABLE SHALL BE PROVIDED WITH PERMANENT (ANCHORED PER NEC). SUCH ANCHORING SHALL BE INDEPENDENT OF THE CEILING SUPPORT SYSTEM. ALL FIXTURES SHALL BE APPUCATIONS. ALL STROBE ALARMS SHALL BE ADA COMPUANT, MINIMUM 75CD PER ADA. �f� ""' �/ ALL EQUIPMENT & SYSTEM IDENTIFICATION NOMENCLATURE SHOWN ON DRAWINGS OR LISTED HEREIN IS SHOWN FOR GENERAL DESIGN INSTALLED PLUMB AND LEVEL. SUPPORT SURFACE MOUNTED FIXTURES GREATER THAN 2 FEET IN LENGTH AT A POINT IN ADDITION TO T_ F ADHE=SIVE LABELING IDENTIFICATION BY THIS CONTRACTOR. PROVIDE TRANSPARENT ADHESIVE COVERINGS OVER EACH LABEL„ WRAPPED Le) AND INSTALLATION REFERENCE ONLY. THE ACTUAL NAMEPLATE, ETC. NOMENCLATURE FOR THIS PROJECT SHALL BE VERIFIED BY THE OUTLET BOX FIXTURE STUD. ALL NEW WIRING SHAD BE INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURER'S REQUIREMENTS AND IN CONDUIT (3/4" n AROUND THE LABELS AT LEAST TWO TIMES. THE LONG MAXIS OF THE LABELS SHALL INSTALLED BE PARALLEL TO THE LONG AXIS OF O ill. ELECTRICAL CONTRACTOR IN FIELD PRIOR TO FABRICATION AND WHERE APPLICABLE, SHALL BE AN EXTENSION OF EXISTING MINIMUM). FIRE ALARM SYSTEM WIRING SHALL BE INSTALLED INA RACEWAY SYSTEM SEPARATE FROM SECURITY SUB-SYSTEM WIRING Q r� NOMENCLATURE USED ON THE SITE AS DETERMINED IN FIELD BY ELECTRICAL CONTRACTOR. THE RESPECTIVE CABLE ASSEMBLIES. LABELS SHALL BE APPROXIMUATELY 1-1/2" LONG BY 3/8" HIGH. REPLACE DEFECTIVE LAMPS FOR A PERIOD OF ONE YE1AR FOLLOWING THE TIME OF SUBSTANTIAL COMPLETION. WHERE USED FOR WHERE/IF APPLICABLE. 0) Q. VJ INSTALL POWER CABLES IN A MANNER WHICH PREVENTS OVER-HEATING. OTHERWIst, WHEREVER POSSIBLE. BUNpIE CABiJr5 OF THE TEMPORARY LIGHTING PRIOR TO TIME OF SUBSTANTIAL COMPLETION, REPLACE ALL INCANDESCENT UGHTING FIXTURE LAMPS, AS WELL IN ADDITION TO THE ABOVE, ALL LABELING FOR ALL ELECTRICAL WIRING WORK (FOR ALL SYSTEMS) SHALL BE 3M DCI NO. AS ANY LAMPS WHICH ARE DEFECTIVE, DAMAGED OR BURNED OUT. THE INSTALLATION SHALL INCLUDE A COMPLETE SYSTEM TEST OF THE EQUIPMENT BY THE LOCAL REPRESENTATIVE OF THE SYSTEM SAME SYSTEM TOGETHER. ALSO PROVIDE COLOR CODED JACKETS, OR OTHER APPROVED LABELLING/IDENTIFICATION METHOD, TO W 054007-1 1 9 54 "SWD" WRITE-ON TAPE DISPENSER KIT WITH FACTORY PROVIDED SPECIAL FAST DRYING MARKER INCLUDED WITH KIT. INSTALLED. THIS TEST SHALL BE PERFORMED IN THE PRESENCE OF REPRESENTATIVES OF THE OWNER, ENGINEER, MND LOCAL FIRE I RLL MARKINGS SHALL BE CLEAR AND LEGIBLE. IDENTIFY RUNS OF DIFF RENT SYSTEMS. FOR ALL EXISTING FIXTURES WHICH ARE SCHEDULED FOR REUSE, REMOVE FROM EXISTING CEILINGS DURING DEMOLITION; PROTECT DEPARTMENT. I ALL CABLES WHICH ARE NOT ROUTED IN CONDUIT SHALL BE NEATLY BUNGLED, SECURED AT FOUR FOOT INTERVALS AND IDENTIFIED DURING CONSTRUCTION; CLEAN, SERVICE (IF REQUIRED), RE-LAMP (WITH LAMPS TO MATCH BUILDING STANDARD OR PER THIS _.__�-_ —_ '_._. AS DETERMINED IN FIELD, PROVIDE COLOR CODING FOR JUNCTION BOXES, PULL BOXES AND ASSOCIATED PLATES TO MATCH EXISTING AT TEN FOOT INTERVALS. WHEREVER POSSIBLE, BUNDLE CABLES OE THE SAME SYSTEM TOGETHER. PROVIDE ADDITIONAL WALL OITLET SECTION AS NOTED) AND REINSTALL AT LOCATIONS INDICATED. PROVIDE ALL REQUIRED MODIFICATIONS (CARDS, POWER SUPPLIES, HARDWARE, FIRMWARE, SOFTWARE, ETC.) TO THE EXISTING FIRE BUILDING STANDARDS. THE FOLLOWING INSULATION COLOR CODE SHALL BE USED FOR SYSTEM AND VOLTAGE IDENTIFICATION FOR BOXES AND ADDITIONAL WHIPS AS IF REQUIRED AT SYSTEMS FURNITURE TO ACHIEVE SAME. ALARM SYSTEM AS REQUIRED TO RENDER THE ENTIRE EXTENSION FULLY OPERABLE. FEEDER AND BRANCH CIRCUIT WIRING. / FOR ALL EXISTING FIXTURES WHICH ARE SCHEDULED TO BE REMOVED AND TURNED OVER TO OWNER, THE FIXTURES SHALL BE DISCONNECTED, CAREFULLY REMOVED AND TURNED OVER TO OWNER. TRANSFER SUCH FIXTURES TO STORAGE AREA AS DIRECTED IN PROVIDE ALL REQUIRED 20A/120VAC POWER AS REQUIRED TO ENERGIZE ALL NEW FIRE ALARM RELATED COMPONENTS. THIS 277/48OV SYSTEM - BROWN, ORANGE, YELLOW & GRAY {NEUTRAL) 'J-HOOK" PATHWAYS FIELD. REQUIREMENT APPLIES WHETHER OR NOT SUCH POWER WORK IS SHOWN ON THE DRAWINGS. BRANCH CIRCUITS SERVING FIRE ALARM 120/208V SYSTEM - BLACK, RED, BLUE & GRAY (NEUTRAL) RELATED EQUIPMENT SHALL BE DEDICATED TO FIRE ALARM RELATED EQUIPMENT ONLY. EQUIPMENT GROUNDING - GREEN CABLE DISTRIBUTION BRIDLE RINGS SHALL BE EQUAL TO CADDY #4BRT64 OR MONO-SYSTEMS INC. THE HOOK" (MINIMUM 4" IL. - _-liJ�lAt ICAL F Z Z SYSTEMS - TO MATCH EXISTING - VERIFY IN FIELD. DIAMETER DR 4" SQUARE USABLE INTERNAL AREA) CONSTRUCTED OF ALUMINUM OR CORROSION RESISTANT STEEL WITH ROLLED SMOKE DETECTOR LOCATIONS SHALL NOT EXCEED THE RATED COVERAGE OF THE DETECTOR AND, IN GENERAL, SHALL BE NO MORE CS O EDGES OR EQUIVALENT TO PREVENT DAMAGE TO CABLE JACKETS AND INSULATION. PROVIDE SPLITS OR OPENINGS SO THAT CABLES PROVIDE ALL CONDUIT ANO OUTLET BOXES AS REQUIRED FOR ALL CONTROL WIRING AND THERMOSTATS. FURNISH AND INSTALL POWER THAN 15 FEET FROM A WALL OR 30 FEET APART. SMOKE uc1c. ,v,..a SHALL NOT BE INSTALLED WITHIN 3 FEET FROM A SUPPLY AR d GBCRA iG CAN BE LAD IN THE RINGS RATHER THAN THREADED THROUGH. PROVIDE MAXIMUM 30% FILL (IN CROSS SECTION), BASED ON WIRING AND MAKE LINE CONNECTIONS TO ALL HEATING. VENTILATING AND AIR CONDITIONING EQUIPMENT. ELECTRICAL CONTRACTOR DIFFUSER. PROVIDE CONTACT BASES FOR ALL APPLICATIONS WHERE AUXILIARY CONTACTS ARE REQUIRED. E2 OUTSIDE DIAMETER OF CABLES. ACCORDINGLY, PROVIDE MULTIPLE SETS OF RINGS ALONG ANY ROUTES AS/IF REQUIRED. SHALL EXAMINE THE APPROVED DRAWINGS OF ALL BRANCHES AND SHALL WIRE AND CONNECT ALL MOTORS, DISCONNECTS. CONTROL N ALL METALLIC CONDUIT, SURFACE WIREWAYS, SUPPORTS, CABINET AND EQUIPMENT SHALL BE GROUNDED IN ACCORDANCE WITH THE= DEVICES AND OTHER ITEMS REQUIRING ELECTRICITY FOR OPERATION. THIS CONTRACTOR SHALL MAKE THE NECESSARY ELECTRICAL THE AUDIO/VISUAL AND VISUAL-ONLY ALARM INDICATING DEVICES SHALL BE RED ADA-COMPLIANT UNITS (WITH MINIMUM 75 CANDELA p Q LATEST ISSUE OF THE NATIONAL ELECTRICAL CODE AND AS SHOWN ON PLANS. THE GROUND TERMINALS OF RECEPTACLES SHALL BE PROVIDE RINGS AT FOUR FOOT INTERVALS AND AT ALL OFFSETS. ROUTE RINGS THROUGH CORRIDORS AND SIMILAR OPEN AREJAS CONNECTIONS BETWEEN THE SPECIFIED EQUIPMENT AND THE JUNCTION BOX NEAR EQUIPMENT WITH FLEXIBLE METALLIC CONDUIT AND ,ADA-COMPLIANT STROBES) WALL MOUNTED AT 6'B" AS SHOWN ON PLANS. STROBE UNITS SHALL BE SYNCHRONIZED WHEREVER MATCHED CONNECTORS. NO FLEXIBLE CONDUIT SHALL BE EXPOSED IN FINISHED ROOMS. EACH MOTOR SHALL HAVE DISCONNECT CONNECTED TO THE EQUIPMENT GROUND 8U5 OF THE SOURCE BRANCH CIRCUIT PANELBOARD. ALL GROUNDING CONDUCTORS SHALL WHEREVER POSSIBLE TO MINIMIZE WALL PENETRATIONS. SECURELY ANCHOR (MECHANICAL - NOT ADHESIVE) ALL RINGS DIRECTLY TO REQUIRED BY ANY AUTHORITY HAVING JURISDICTION, INCLUDING ADAAG. ADDITIONALLY, WHERE REQUIRED BY LOCAL AUTHORITY, THE SWITCH OR MANUAL STARTER INSTALLED BY THIS CONTRACTOR AHEAD OF MOTOR OR MOTOR MAGNETIC STARTER. THE ELECTRICAL BE PROTECTED FROM MECHANICAL INJURY. ALL CONNECTIONS TO EQUIPMENT OR CONDUIt SHALL BE MADE WITH AN APPROVED S1RUCIURAL COMPONENTS OF THE BUILDING. RINC5 SHALL NOT BE ANCHORED TO DUCTWORK, CONDUIT, PIPING, FIXTURES, STROBES MUST MEET ANSI 53.41 TEMPORAL CODE. CONDUCTOR AND SAME SHALL BE BOLTED OR CLAMPED TO EQUIPMENT AND CONDUIT. ALL CONTACT SURFACES SHALL BE EQUIPMENT, CEILING SUPPORTS, ETC. ALL RINGS SHALL BE FULLY AND READILY ACCESSIBLE AFTER INSTALLATION. NEATLY ROUTE CONTRACTOR SHALL PROVIDE CONTROL AND INTERLOCK WIRING AS SPECIFICALLY INDICATED ON THE DRAWINGS. ALL OTHER CONTROL WIRING REQUIRED FOR OPERATION OF THE SYSTEMS SHALL BE PROVIDED BY THE HEATING CONTRACTOR. 1HOROUGHLY CLEANED AND BRIGHT BEFORE CONNECTIONS TO INSURE A GOOD META_ CONTACT. BRIDLE RING PATHS PARALLEL ANp PERPENDICULAR TO BUILDING ARCHITECTURAL LINES AND AT A CONSISTENT ELEVATION WHEREVER THE WAII~RFLOW SWITCHES, TAMPER SWITCHES AN❑ PRESSURE SWITCHES SHALL BE PROVIDED BY THE SPRINKLER CONTRACTOR. THE POSSIBLE. 1� � � ln� ELECTRICAL CONTRACTOR SHALL WIRE AND PROVIDE THE RELATED MONITOR MODULES AS REQUIRED. ALL NEW FEEDERS AND BRANCH CIRCUITING INSTALLED UNDER THIS CONTRACT SHALL BE PROVIDED WITH EQUIPMENT GROUNDING CONDUCTORS SIZED AND INSTALLED IN ACCORDANCE WITH LATEST ISSUE OF THE NATIONAL ELECTRICAL CODE ARTICLE 250 AND AS ROUTE ALL BRIDLE RING PATHS AND CABLES PERPENDICULAR AND PARALLEL TO THE BUILDING ARCHITECTURAL LINES, KEEPING PROVIDE ISOLATION MODULES AS REQUIRED TO ISOLATE WERE TO WIRE SHORTS ON A DATA LOOP TO LIMIT THE NUMBER OF OTHER SHOWN ON PIANS. P N V RTTCAL OFFSETS DISCONNECTS• STARTERS & FUSES: OFFSETS TO A MINIMUM. INSTALL BRIDLE RINC5 IN A UNIFORM PLANE ELEVATION WHEREVER POSSIBLE KEE I G E MODULES OR urrlr..I�rt.S THAT ARE INCAPACITATED BY THE SHORT CIRCUIT FAULT AND OR GROUNDS. 150IATION MODULES SHALL BE TO AN ABSOLUTE MINIMUM. PRIOR TO INSTALLATION, SUBMIT SCALED COORDINATION DRAWINGS SHOWING ALL PROPOSED ROUTING AND PART OF THE SMOKE DETECTOR BASE. THE ISOLATION MODULES SHALL PERMIT THE ENTIRE SYSTEM TO OPERATE INDEPENDENTLY OF a �- OOMLIE ANO �TM+� RING LOCATIONS FOR REVIEW BY OWNER. KEEP OFFSETS TO AN ABSOLUTE MINIMUM. BRIDLE RING PATHS SHALL BE ROUTED SO THAT SUBJECT TO COMPLIANCE WITH REQUIREMENTS. PROVIDE EQUIPMENT OF ONE OF THE FOLLOWING (FOR EACH TYPE AND RATING): THE AREA DISCONNECTED BY THE ISOLATION MODULE DUE TO WIRING FAULTS. o ALL. WIRING FOR L,rrt,•,t,IT POWER VOLTAGES SHALL BE INSTALLED IN RACEWAY SYSTEMS SEPARATE FROM EACH OTHER (I.E. 24V A MINIMUM DF 24' EXISTS BETWEEN ANY CABLES AND ANY EMI SOURCE SUCH AS BALLASTS, MOTOfRS. POWER WIRING, ETC. SQUARE 0 CO. -••--- --•- PROVIDE MONITOR MODULES AS REQUIRED TO INTERFACE "NON-•INTEWGENT" DEVICES INTO THE SYSTEM AS SHOWN ON THE SEPARATE FROM 120/208V). ONLY VOICE AND DATA CABLES MAY SHARE RACEWAYS. 12 SET- .LuirceoN Allo SKRirltlBo DISCONNECT SWITCHES SHALL BE EQUAL TO SQUARE D TYPE HD. ALL SAFETY SWITCHES/DISCONNECTS SHALL BE HEAVY DUTY, DRAWINGS (I.E. SPRINKLER FLOW SWITCHES, TAMPER SWITCHES, ETC.). " ALL WIRING SHALL BE RUN IN CONDUIT. THIN WALL EMT CONDUIT SHALL BE USED, SIZES 3/4" (MINIMUM) THROUGH 2-1/2". ALL GANG TYPE OUTLET BOXES SHALL NOT BE USED. THE OUTLET BOX LOCATIONS INDICATED ON DRAWINGS SHALL BE CONSIDERED SAFETY TYPE, QUICK MAKE AND QUICK BREAK AND EXTERNALLY OPERATED. UNLESS NOTED OTHERWISE DN DRAWINGS OR DIRECTED "'- "' L. OTHERWISE IN FIELD, ALL DISCONNECT SWITCHES SHALL BE FUSED. UNLESS NOTED OTHERWISE QN DRAWINGS OR DIRECTED PROVIDE CONTROL MODULES FOR ALL AUXILIARY DEVICES INCLUDING ALL SUPERVISED CONTROL FUNCTIONS SUCH AS AR HANDLER p _ 1 U CONDUITS LARGER THAN 2-1/2' SHALL BE HEAVYWALL CONDUITS INSTALLED UNDERGROUND OR IN CONCRETE SLABS SHALL BE FVC APPROXIMATE, AND THEREFORE, IT SHALL BE INCUMBENT UPON THIS CONTRACTOR TO STUDY THE GENERAL CONSTRUCTION WITH SHUTDOWNS. o �` 0 JACKETED FLEXIBLE STEEL CONDUIT. SEALTTTE SHALL BE USED IN WET AREAS AND ON ALL MOTORIZED EQUIPMENT. FLEXIBLE CONDUIT RELATION TO SPACES MND EQUIPMENT SURROUNDING EACH OUTLET. ALL OUTLET, SWITCH AND JUNCTION BOXES SHALL BE MADE OF OTHERWISE IN FIELD, BRACE ALL DISCONNECT SWITCHES FOR 200,000 A.I.C. PROVIDE HEAVY-DUTY SWITCHES, WITH FU5E5 OF 1 CE MAY ONLY BE USED FOR FINAL CONNECTIONS. NO BX, ROMEX, ARMORED CABLE, ETC. SHALL BE ALOWED. ALL VISIBLE CONDUIT CODE GALVANIZED STEEL COMPLETE WITH RINGS AND SCREW COVER PLATES AND LOCATED WHERE SHOWN AND NOTED ON DRAWINGS. CLASSES AND CURRENT RATINGS INDICATED AND UL LISTED FOR USE AS SERVICE EQUIPMENT UNDER UL STANDARD 98 OR 869. SEE rn m m L` SHALL BE RIGID. ALL FITTINGS FOR SAME SHALL BE SET SCREW TYPE STEEL, WITH INSULATED THROATS. ALL WIRING OF ALL SYSTEMS WHERE CONDUIT 15 CONCEALED, BOXES SHA L NOT BE LESS THAN 4" SQUARE X 1-1/2' DEEP. ALL BOXES SHALL BE EQUIPPED SECTION "FUSES FOR SPECIFICATIONS. WHERE CURRENT UNITING FUSES ARE INDICATED, PROVIDE SWITCHES WITH EXTERIOR/ROOF MOUNTED DUCT SMOKE DETECTORS SHALL BE IN A NEMA4X ENCLOSURE. cn a SHALL BE INSTALLED IN CONDUIT UNLESS SPECIFICALLY INDICATED OTHERWISE HEREIN OR ON DRAWINGS. WITH PROPER COVERS TO BRING FLUSH WITH FINISHED WALL SURFACE. NON-INTERCHANGEABLE FEATURE SUITABLE ONLY FOR CURRENT LIMITING TYPE FUSES. INSTALL DISCONNECT SWITCHES WITHIN SIGHT 21 OIICT 511AKE p m C ' 4) OF CONTROLLER POSITION UNLESS OTHERWISE INDICATED. z V i,'. PROVIDE ALL REQUIRED 20A/12OVAC POWER AS REQUIRED TO ENERGIZE ALL FIRE ALARM RELATED COMPONENTS. THIS REQUIREMENT m o W EXPOSED CONDUIT SHALL BE SECURELY SUPPORTED IN PLACE PER CODE BUT ON A MAXIMUM OF 10 FOOT INTERVALS, WITHIN WHERE OITLET BOXES OCCUR IN BLOCK, CINDER, OR CONCRETE BLOCK, FACING TILE OR OTHER MATERIAL WHERE SUCH MATERIALS APPLIES WHETHER OR NOT SUCH POWER WORK IS SHOWN ON THE DRAWINGS. BRANCH CIRCUITS SERVING FLARE ALARM RELATED U w o r y„_ THREE FEET OF EACH BEND, AT EVERY OUTLET OR JUNCTION BOX AND AT THE END OF EACH STRAIGHT RUN TERMINATING ATA BOX FORM THE FINISHED WALL SURFACE, THE OPENING FOR THE BOX SHALL BE CUT NEATLY AND OF THE SIZE THAT THE COVER PLATE EXCEPT AS OTHERWISE INDICATED, PROVIDE MOTOR STARTERS AND ANCILLARY COMPONENTS; OF TYPES, SIZES, RATINGS AND EQUIPMENT SHALL BE DEDICATED TO FIRE ALARM RELATED EQUIPMENT ONLY. REFER TO MECHANICAL DRAWINGS FOR REQUIREMENTS_ C) z Y OR CABINET. CONDUIT SHALL NOT BE SUPPORTED FROM DUCTWORK OR PIPE WORK. CONDUITS SHALL BE RUN PARALLEL TO AND AT WILL COVER ALL PARTS OF THE OPENING. CONDUIT SHALL BE USED ON EXPOSED RACEWAYS. IN GENERAL, JUNCTION BOXES SHALL ELECTRICAL CHARM-se,.:,,,.:, INDICATED, WHICH COMPLY WITH MANUFACTURER'S STANDARD MATERIALS, DESIGN AID CONSTRUCTION IN 3 3 w cw=n J C ACCORDANCE MATH PUBLISHED PRODUCT INFORMATION, AND AS REQUIRED FOR COMPLETE INSTALLATIONS. AU_ STARit.NS SHALL BE 6 O RIGHT ANGLES TO THE BUILDING LINES. GENERALLY, CONDUIT SHALL BE RUN IN CONTACT WITH STRUCTURAL PARTS OF THE BUILDING BE FURNISHED AND REQUIRED BY THE NATIONAL ELECTRIC CODE, OE THE PROPER SIZES, AND SHALL BE CONSTRUCTED OF X12 d p cz.., Lr SO AS TO AVOID SUSPENDED LENGTHS OF CONDUIT. CONDUIT SHALL BE INSTALLED AS TO BE ACCESSIBLE FOR REPLACEMENT AND GAUGE STEEL WITH REMOVABLE FRONT FASTENED ON WITH COUNTER SUNK HEAD SCREWS OR OTHER APPROVED MEANS. FOR SPECIAL EQUIPPED WITH PILOT LIGHTS. ALL STARTERS SHALL BE SIZED ACCORDING TO LOAD BEING SERVED OR AS NOTED ON DRAWINGS, MAINTENANCE AND GENERALLY, CONDUIT SHALL BE INSTALLED TO PERMIT DRAINAGE. APPLICATION, JUNCTION BOXES SHALL BE NOTED, DETAILED AND/OR SIZED ON THE DRAWINGS OR IN THE FIELD AS REQUIRED. WHICHEVER REQUIREMENT IS LARGER. MANUAL AND MAGNETIC STARTERS THERMAL OVERLOAD ELEMENTS SHALL BE RATED BETWEEN Q 115% AND 125% FULL LOAD CURRENT OR AS CALLED FOR UNDER NEC. INSTALL AND CONNECT CAPACITORS FURNISHED BY HVAC 'A� WHERE DRYWALL CEILINGS ARE USED, THE ELECTRICAL CONTRACTOR SHALL NOT INSTALL JUNCTION BOXES ABOVE THE CEILING IN CONTRACTORS AHEAD OF OVERLOADS WHERE APPLICABLE. O INACCESSIBLE LOCATIONS. FIELD COORDINATE WITH THE CONSTRUCTION MANAGER PRIOR TO ROUGH-IN TO AVOID ANY CONFLICTS. JUNCTION BOXES ABOVE LAY-IN CEILINGS ARE ACCEPTABLE. Z