Loading...
Plans (7) BU P2018-00344 . r 10 2684 INFORM RESTAURANT ACCOUNTING Ti c', •, rE i i 4. , .. f;. OR 4 of c I TIGARD , OREGON RECEIVED L4 N DEFERRED SUBMITTALS DEC 12 2018 N CITY OF TIGARD N 5. 3UILDING DIVISION MECHANICAL ELECTRICAL (INCLUDING LIGHTING) co INFORM RESTAURANT ACCOUNTINGTENANTRELEASES *DESIGN-BUILD CONTRACTOR SHALL COMPLETE, AS NECESSARY, REQUIRED - �, PORTIONS OF THE OREGON ENERGY COMPLIANCE FORMS N a 7360 SW HUNZIKER RD, SUITE 205 **CONTRACTOR TO SUBMIT DEFERED SUBMITTAL DESIGN DRAWINGS TO ` 04 N TIGARD, OR 97223ARCHITECT FOR REVIEW AND APPROVAL PRIOR TO SUBMISSION TO CITY FOR `„ COVER SHEET PERMIT REVIEW. Q Z • CS1 COVER SHEET 0n tz \ ARCHITECTURAL o BUILDING CODE SUMMARY W • • T1.1 FLOOR PLAN, RCP AND DETAILS ROBINSON CIsISTRUC1' IONCONTRACTORGOVERNING CODS 2014 OREGON STRUCTURAL SPECIALTY CODE N r- N OCCUPANCY TYPE: GROUP B EXISTING - GROUP B PROPOSED DESCRIPTION OF WORK SPRINKLERED VS. NON-SPRINKLERED: NON SPRINKLERED 21360 NW AMBERWOOD DR CONTACT: CHRIS ROBINSON CONSTRUCTION TYPE: V-A HILLSBORO, OR 97124 SUITE CONTINU08IS AN TO BE USEDlNG OFFICE,AS OFFICES.GSOUP COPEBOF WORK INCLUDES WILL NCLUDESN W TENANT PORTABLE ): TELEPHONE: 503.645.8531 IMPROVEMENT, WITH ADDITION OF NEW INTERIOR PARTITIONS. FIREFIRE EXTINGUISHERS INGUISEXERS SHALL BBE(OSSC PROVIDED PORTABLE IN OCCUPANCIES AND LOCATIONS AS REQUIRED BY FAX: 503.645.5357 THE OREGON FIRE CODE AND THE FIRE MARSHALL ZONING CODE INFORMATION QCCueANCY LOAD (OSSC 1004): GROSS FLOOR AREA (SUITE 205): 760 SF / 100 - 8 OCCUPANT LOAD TAX MAP & LOT: 2S101DBOO103 (SEE ALSO OCCUPANT LOAD TABLE ON THIS SHEET) C IAINC. ARCHITECT ZONING: C-P PROFESSIONAL COMMERCIAL MEANS NA ONOF EGRESLI(LUMC�QO6.2osC 1006): IL ): #1 MINIMUM 1 FOOT-CANDLE AT THE WALKING SURFACE LEVEL ILL15895 SW 72ND AVE SUITE 200 CONTACT: KAMELIA KARGAR EMERGENCYEMIOEMERGENCY POWER (OSSCDU1006.3):ORA FLS/DEMO PLAN LEGEND POWER SHALL BE PROVIDED FOR A DURATION OF 90-MINUTES MINIMUM AREAS REQUIRED TO BE ILLUMINATED BY EMERGENCY POWER PORTLAND, OR 97224 - CORRIDORS AND EXIT PASSAGEWAYS LI - INTERIOR EXIT DISCHARGE ELEMENTS TELEPHONE: 503.226. 1 285 e) COMMON PATH OF EGRESS - EXTERIOR LANDINGS FAX: r� ARCHITECTURE X 503.226. 1 670 EMERGENCY POWER FOR ILLUMINATION (OSSC 1006.3): RGINEETING um 4 PATH OF EGRESS INITIAL ILLUMINATION: 1 FOOT-CANDLE AVERAGE W/ 0.1 FOOT-CANDLE MINIMUM AT ANY POINT AT FLOOR LEVEL PLANNING EXIT SIGN LOCATION SHADED QUADRANT END OF EMERGENCY LIGHTING PERIOD: INTERIORS ® 0.6 FOOT-CANDLE AVERAGE W/ 0.06 FOOT-CANDLE MINIMUM AT ANY POINT AT FLOOR LEVEL INDICATES DIRECTION (VERIFY EXISTING LOCATION FOR RE-USE IN PLAN) Exir SIGNS (QS= 1411); 15895 SW 72ND AVE SUITE 200 SEE 1/CS 1 AND 2/CS1 FOR LOCATIONS OF EXIT SIGNAGE PORTLAND, OREGON 9722 4 OSSC 1004 OCCUPANT LOAD TABLE T E L : 5 0 3 . 2 2 6 . 1 2 9 5 ILLUMINATION (OSSC 1011.3): P AX : 5 0 3 . 2 2 s . 1 s 7 0 OFFICE COPYROOM EXIT SIGNS SHALL BE INTERNALLY OR EXTERNALLY ILLUMINATED Www . C I D A I N C . C o M WY OP TIGARD NAME OCCUPANCY TYPE FACTOR AREA LOAD COMMON PATH OF EGRESS TRAVEL (OSSC 1Q14)1 REVIEWED FOR CODE COMPLIANCE VALIDITY OF PERMIT 201 OPEN OFFICE BUSINESS 100 644 6 (TABLE 1014.3) THE ISSUANCE OF A PI=i�MIT 202 OFFICE BUSINESS 100 116 1 NON SPRINKLERED BUILDING, B OCCUPANCY: 100'-0" Appro BASED ON CONSTRUCTION TOTAL FOR OCCUPANT LOAD 760 8 ACTUAL COMMON PATH OF TRAVEL DISTANCE, B OCCUPANCY: 54'-7" OTC;V 1 - DOCUMENTS AND OTHER Permit #t d DATA SHALL NOT PREVENT Off XACOS TRAVEL DISTANCE (OSSC j01 6): li THE CODE OFFICIAL FROM (TABLE 1016.2) Addresst 4" e 1.. ,24:1REQUIRING THE CORRECTION NON-SPRINKLERED BUILDING, B OCCUPANCY: 2001-0" ALLOWED z Suite#i OF QRS.OSSC 105.4 EXIT ACCESS TRAVEL DISTANCE, B OCCUPANCY: 113'-7" EGRESS (TABLE 1021.2) Byt Dates -1�} _ 1 AREA OF WORK TOTAL OCCUPANTS: 8 OCCUPANTS 1 EXIT REQUIRED " • • u 1 EXIT PROVIDED Cr to OFFICE ACCESSIBILITY (QSQ,CHA 11 AND ANSI CHAPTER 5); N FI20SEE FLOOR PLANS FOR REQUIRED CLEARANCES AT DOORS, TOILET ROOMS (EXISTING) AND FIXTURES. W JH, ALL SIGNAGE GRAPHICS, LOCATION AND MOUNTING TO COMPLY WITH OSSC CHAPTER 11 1— M i • • • ,. • • • CC U) N .� 1 A ,..... E • oa) zin -� . . Z Q z W -. ° OPEN OFFICE • ° L7=7 ° t 0 O 7Ur - 201 ( • CC CD T • a U-1 CC El} T o N 0 • I SW DARTMOUTH S � Q ift=.1 N.... 1 _JH / 7„.4 RI ___,, Lam- --r-TI GARnEN ` : ` OUG DR, r.� _ NOT IN SCOPE ® � • Sw ELMHURST ~ 4—U--1711) , , „ �• 0 5W HERMOSO WAY �+' cA V G :2 1 _____ .4rr S FT.ANKLIN �! n a `o (� I I + i = 5W 1 BEVEL4ND f o a s N 0 .�Alt ± I 3,c 01)=-D 0{ i 1 1 �' s CD E 44._ 4t TREEC < IX CIO § c0 co rn ?.1 1401=11 W HU I. a_ _J SW 1AMPTON Sr. A ci z0 m (Ls. N )0 C a \ NZrkER RD g„ g,, o c., til + -�- 111111 SW‘ 4- CRESTVIEW S . ° tire/P�SF tAt o v •i NOT IN SCOPE SW VARNS ST S'Y.( TH r yyf C3 47, t9 Z I 2 u---- 1 gU z� . SW ISANDBURC ST:* !- / - Q a' 4 `g�` _ rio § / 1 . SW TECH CENTER 0 . P + 1 _ , ► I � 11— . _ �. i J0'' T. COVER SHEET 3 '' ,'' CT. 5W LANDMARK N. E _ - CS1 I_ NORTH NORTH NOR4111C1 EGRESS PLAN -- FIRST FLOOR EGRESS PLAN -- SECOND FLOOR M 3 VICINITY MAP my NOT TO SCALE NOT TO SCALE (1) CS1 NOT TO SCALE JOB NO. 180334.01 ia © 2018 O(W P.C./CD ALL RIGHTS RESER' D 0 O CJ D VEr FLOOR PLAN LEGEND RCP LEGEND 9'-10 1/2"± Fa .S r , FQF _ - OFFICE ROOM NAME & NUMBER (E) EXISTING - -- - - 2$84 7u_ 1 ❑ \ I FOF FACE OF FINISH p - ❑ �` +' S. BROOKS p 1 .,.� 1 1.:.:=���.-.���9 (N) INTERIOR PARTITION • • I 1 (E) INTERIOR PARTITION TO REMAIN A WALL TYPE 2X2 (E) LAY IN ACOUSTICAL •CEILING GRID 3 1 r''''' '''''' TO REMAIN 1w4J FIRE EXTINGUISHER1 t 1 'o� I 1 w - goi PT-1 ACCENT PAINT (TBD) �`- - - � - �. - - � • = I 1 I I 1 -'- I 1 OFFICE 1 L ` 3r r I(:t L ` -,1 ` 2X4 (E) LAYIN FLUORESCENT LIGHT FIXTURE TO N 1 202 _ 1 202 REMAIN AS SHOWN N ' I A-- 1 FLOOR PLAN KEYNOTES 1 = I (E) COLUMN _ 2X4 (N) LAYIN FLUORESCENT LIGHT FIXTURE 1 0 r''''''' , RELOCATED AS SHOWN 1 1 I I I n _ _ i [F--=_,= - 1 n A-202 I L - _...:11-,J L - _ - --,! - 1 J �J I11 11 2X4 (E) LAYIN FLUORESCENT LIGHT FIXTURE DEMO 1 1 FLOOR PLAN GENERAL NOTES �� L = - - _ J FOR RELOCATION AS SHOWN 1 L - - -'I co r '11 - I. .1 al i• I. - - In - - El 1 1. ALL CONDITIONS SHOWN OR IMPLIED ON THE DRAWINGS SHALL BE Q I VERIFIED BY THE CONTRACTOR PRIOR TO CONSTRUCTION. NOTIFY `N 1 ARCHITECT / ENGINEER OF ANY DISCREPANCIES PRIOR TO THE START \ a 1 OF WORK. RCP GENERAL NOTES 1 N 2. ALL DIMENSIONS ARE TO CENTER OF WALL UNLESS NOTED OTHERWISE. (E) DEMISING WALL 7-7,- ` 1 1. THIS DRAWING IS DIAGRAMMATIC AND FOR DESIGN PURPOSES 3. PORTABLE FIRE EXTINGUISHERS SHALL BE PROVIDED AND INSTALLED ASONLY. ALL DIMENSIONS BE FIELD VERIFIED. 1 /(E) REQUIRED BY APPLICABLE STANDARDS I ` LE L - - -� - 2. ELECTRICAL CONTRACTOR TO VERIFY MINIMUM EMERGENCY EXIT o m 1■ 0 4. PROVIDE BLINDS PER BUILDING STANDARD, IF NECESSARY. 0 0 ILLUMINATION WITH BATTERY BACKUP AT EGRESS PATH OFo w Q 1 OPEN OFFICE OP N OFFICE_ TRAVEL - PROVIDE 1 F.C. MIN. EMERGENCY LIGHTING AT PATH Lj a. a 1 0 201 5. PATCH AND REPAIR (E) FINISHES TO MATCH WHERE DAMAGE HAS � at I OF TRAVEL. THIS LEVEL MAY DIMINISH TO NOT LESS THAN 06 in in T N ,-., 1 OCCURRED DUE TO CONSTRUCTION. PAINT ALL NEW WALLS (U.N.O.) F.C. OVER 1.5 HOURS OF OPERATION. TO MATCH (E). 1 3. PATCH AND REPAIR (E) GRID & TILE WHERE DEMO HAS 1 6. ALL ELECTRICAL OUTLETS TO CONFORM W/ 2014 OREGON SPECIALTY ` '` OCCURRED. PROVIDE NEW TILES (TO MATCH EXISTING) AS 1 ELECTRICAL CODE. I 1 ` REQUIRED FOR "LIKE NEW" INSTALLATION. 1 4. VERIFY (E) EXIT SIGNS AND PROVIDE SIGNAGE AS SHOWN. 1 WALL TYPES 1 1 _ NEW INTERIOR PARTITION - NON-LOAD BEARING A al1/l/1111111 ///N 61 3625162-33 METAL STUDS, 24" O.C. TO UNDERSIDE OF ~.4 SUSPENDED CEILING WITH (1) LAYER 5/8" GYPSUM BOARD ` I EACH SIDE. PROVIDE GLASS OR MINERAL FIBER INSULATION I FULL DEPTH OF CAVITY. PROVIDE (1) LAYER OF 5/8" ` 1 . OWET SIDE AT WET I 1 o LOCATIONS.WALTER --RESISTANT SEEGYPDETAILBARD 10/T1.1® I N I I FINISH FLOOR PLAN NOTES 11----11 II it I • I I I (E) ONE HR WALL 1. VERIFY ALL FINISH SELECTIONS WITH TENANT AND OWNER PRIOR TO ORDER/INSTALL. LI - ARCHITECTURE NORTH NORTH ENGINEERING lePARTIAL SECOND FLOOR PLAN PARTIAL SECOND REFLECTED CEILING PLANPLANNING 1/4" 1'-0" 441) 1/4" = 1'-O" i/4''i'-o' INTERIORS DOOR SCI-IEDULE HARDWARE 15895 SW 72ND AVE SUITE 200 PORTLAND, OREGON 97224 DOOR # DOOR HARDWARE OPENING WIDTH DOOR DOOR DOOR FRAME FRAME NOTES DOOR # SCHEDULE T E L : 5 0 3 . 2 2 6 . 1 2 8 5 TYPE GROUP x HEIGHT THICKNESS MATERIAL FINISH MATERIAL FINISH F A X : 5 0 3 . 2 2 6 . 1 8 7 0 TYPE 1 WWW . C1DAINC . COM (E)A-201 -- -- -- -- -- -- -- -- -- (E)A-201 1 1/2 PAIR BUTTS A-202 A 1 31--0"x7'-0' 1 3/4* SC STAINED HMKD PREFINISHED -- A-202 ABBREVIATIONS: 1 EA OFFICE LOCKSET (E) EXISTING HMKD HOLLOW METAL KNOCK DOWN SC SOLID CORE WOOD GL GLASS 1 SET SILENCERS GENERAL NOTES: 1 EA WALL STOP Il 1. THE OPENING FORCE SHALL NOT EXCEED 5 LBS FOR INTERIOR DOORS, 8.5 LBS FOR EXTERIOR DOORS, 1 EA STRIKE Z AND THE MINIMUM FORCE REQUIRED TO CLOSE AND LATCH THE DOOR FOR FIRE DOORS. OSSC 1109.9.9 2. ALL HARDWARE SHALL COMPLY WITH THE REQUIREMENTS OF THE ADA. 3. DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE 1.0 OR EFFORT. ()C N 4. CONTRACTOR TO VERIFY HARDWARE FUNCTION INDICATORS FOR ALL DOORS WITH TENANT PRIOR TO LU ORDER/INSTALL. F_ co ❑ CV cc < (1) CM o Ni. PROVIDE METAL STUD BRACE AT H ❑ a, 6'-O" O.C. TO STRUCTURE ABOVE /� Z Q Z AND TO TOP PLATE OF PARTITION. VLli 0 0 SECURE TO UNDERSIDE OF DECK CC {5 /1 DRIVEN2 FASTENERS I ORP02 WDE1"R TYPE `• , w WITH 0.138" o ril cC W ', V '5' SCREWS- TRIM PANEL)AS -„. 2 5C O . • GYP. BD. REQUIRED PREFINISHED 16 GAUGE �`(E) SUSPENDED CEILING PER PIAN N Er' Q CC Z SHEET METAL CHANNEL �• I -_ 111111111 111111 III 1 CONT. TOP TRACK- ATTACH Te = Q . COLOR TO MATCH �d W/ '1 4 Yrt � WINDOW SYSTEM = SCREWS AT 2'-0” O.C. AND TO TOP _ WALL PER PLAN (DOUBLE STUDS I w AT ALL JAMBS) U) I. — PLATE OF PARTITION W/ (2) 1" .; �" -� TYPE '5' SCREWS - TRIM PANEL AS ..JI IL� ` O •• : REQUIRED - Co _____ r...CO - c� r...N L = HEAD CONDITION0 r` 11111111k 0 + SOUND BATT -- FULL CAVITY AR 1/2� Z �A N �' METAL STUD PARTITION PER PLAN LI. w � I ` E � � , „will", HOLLOW METAL JAMB 3 1 Z SEALANT OVER NEOPRENE E • GASKET-- ATTACH TO BASE 12 c = / " lipOOR PER SCHEDULE STOREFRONT SYSTEM W/ BOTTOM TRACK TO FLOOR WITH 1 4 Ti.T1 E ADHESIVE TAPE = X 3" LAG SCREW ANCHORS AT • 4'-O" O.C. (MAX) AND AT CORNERS (E) INSULATED GLAZING _ AND ENDS / r _ 0 \ 1► (E) ALUMINUM STOREFRONT 4 r. • •f.:• •, SYSTEM MULLION �i \ FLOOR PLAN,RCP AND DETAILS '' CENTERLINE OF STUD \ JAIu18 CONDf110N WALL AND CENTERLINE FINISH FLOOR . \ OF MULLION T1.1 9 NEW WALL @ (E) STOREFRONT MULLION 10 WALL TYPE A DOOR/ RELITE TYPES 12 TYPICAL INTERIOR DOOR DETAIL JOB NO. 180334.01 T1.1 3 4 - 1'-0 DTL-001 1/4" = 1'-O" T1.1 3" = 1'-0" T1.1 3" = 1'-0" DTL-002 " " o / 0 201 CEDJ, P.C./qDA ALL RIpRS RE5FR4ED u 0 v L1]