Plans FPS2O19-00121 , —4,..,,,,,,,,,,,,,,„ FirE4Larm Cinemas Bridgeport „,,„,,,„ :,„ ,,torm ...... Regal cinemas Bridgeport ,:_,::,:: ,, ,„, „,,,,,„., " , „ ,, ... . Theater mit 1 8 I 7329 SW Bridgeport Rd, Tigard, OR 97224 APPLICABLE BUILDING CODES I SCOPE OF WORK i SYSTEM OPERATIONS MATRIX ' FIRE ALARM BILL OF MATERIALS 2014 OSSC w/STATE OF OREGON AMENDMENTS BUILDING DESCRIPTION: EXISTING MOVIE THEATER BUILDING OCCUPANCY: A-1 SYSTEM OUTPUTS SYMBOL CITY MANUFACTURER MODEL DESCRIPTION 2013 NFPA 72 SPRINKLED BUILDING: YES 2012 NFPA 70 PERFORMANCE CLASS: SLC/ NAC BQ 09 EST SIGA-PD OPTICAL SMOKE DETECTOR SCOPE: P a 9 EST SIGA-SB STANDARD BASE I PERFORMANCE SYSTEMS INTEGRATION LLC IS PROVIDING A FIRE ALARM SYSTEM CONSISTING OF: Z z CENTRAL STATION MONITORING z j • REMOVE EXISTING BEAM SMOKE EQUIPMENT IN THEATER #18 °- ., • ADD NEW ADDRESSABLE SMOKE DETECTORS IN THEATER #18 0 tz — TRANSMISSION TYPE: PHONE LINE 04 f: a COMMUNICATION TYPE: z- <d MONITORING COMPANY: Q © � © Q � > ACCOUNT NUMBER: w .._1Lu w PHONE NUMBER: FIRE ALARM SYSTEM MATRIX OF OPERATIONS r,,, 0 < cc SHEET INDEX < 0 z < FIRE ALARM SUBMITTAL REQUIREMENTSce , 1 a. — T` Q v7 CSL Q I F' c4 Q w d Q <C m V) cn I SHEfi ;ESCft?T1 t' R1f E: Q ' Q 1, The work site address and work activity location 'k a 4 _ > �- Q z a © ca a �- 2. Work site owner or tenant contact name, address, and telephone number L LU Ce 5i O O 3. Contractor or installer information,including state electrical license number FA-01 FIRE ALARM PLAN 1 0-< Q n — z "7- O z > > w 4. Description of work c) Q Q z Q („ -. J w 5. Three sets of scaled plans, not smaller than 11 x 17 inches. Your plans must include: z z I C� u, O z Q 21 c , w w 5.1. Floor plan indicating the use of all rooms Q Q a w O , !-- 5.2. Riser Diagram z z > ck Ix © < < ,-- E•-- > O =- ' 5.3. Location of all alarm-initiating devices p Q U J = cmj O Wil- _ _0 > LLt i11 _ ' 5.4. Location of all alarm notification devices,including candela ratings for visible devices I I < < a— c, U 04 w U U < - - 0 p powersuppliesI ,. I_ a Co 5.5. Location of alarm control, transponders,and notification FACP AC POWER LOSS a a • 5.6. Annunciation 5,7, Power connection I - t 'sr cu FACP BATTERY POWER LOSS • a • 5.8. Battery calculationsL I- BPS6A AC POWER LOSS a a a a LLd -�- O U I-- .-.1 O 5.9. Voltage drop calculations BPS6A BATTERY POWER LOSS a a a a LL1 - C? O L a 5.10. Wiring types and sizes — - - 41 c 0 " La - 5,1 1, Manufacturer's data sheets with model numbers and information for equipment, devices, and Ij Cj I- L�«1 -t UL ice ` VICINITY MAP FIRE ALARM SYSTEM OPEN CIRCUIT • • • ! ? 3 0 materials , d ' 5.12. Ceiling height and construction details FIRE ALARM SYSTEM GROUND FAULT • • • ;; I g 5.13. Interface of fire safety control functions FIRE ALARM SYSTEM TROUBLE a a a 1 � a a ELEVATOR MACHINE ROOM SMOKE DETECTOR a a a a a a a a a - w < ELEVATOR MACHINE ROOM HEAT DETECTOR a a a a a a a a *4 2 • 0,..i 1 - WIRE SCHEDULE '4x -' ELEVATOR HOISTWAY HEAT DETECTOR a a • • a a a a 14 ,�x, ,,,. , , . „ 1 NII il glVilIIF - B * Ir i4 - < [ELEVATOR H+OISTWAY SMOKE DETECTOR a a a a • a a • a v° c C) ELEVATOR PRIMARY LEVEL SMOKE DETECTOR a • a a a a a a tflt?“.„:go — 12 AWG PAIR • m ei Z f-',1 14 AWG PAIR • I 'ELEVATOR NON-PRIMARY LEVEL SMOKE DETECTOR a s a a a a a a U_< u 16 AWG PAIR • I I • ' Ip. s; ; _° ',..*: 9 %' j 1 �i 118 AWG PAIR III t [WET SYSTEM SPRINKLER WATERFLOW SWITCH a a a a a. a • • . . . . • ,7329 O1 IFPLR OR FPLP(AS REQUIRED) I �� fF : [SHIELDED I • cI Bridgeport Road ,WET SYSTEM SPRINKLER TAMPER SWITCH a a a B`1 A I 4 � v I-LI 0. [DRY SYSTEM LOW AIR MONITOR a a • .L-. [TWISTED I ...s; , s a a a ffi . - DRY SYSTEM HIGH AIR MONITOR 3 REQUIRED) • E r' £" tit Tf`"1 1 w RATED FOR UNDERGROUND AND WET CONDITIONS(AS REQ „� DRY SYSTEM ALARM MONITOR • • • • �„- ABLE USE wF' ? Fk';•,, , POST INDICATOR VALVE a a a SIGNAL LINE CIRCUIT(SLC) CONVENTIONAL INITIATING DEVICE CIRCUIT(IDC) SpC§ BACKFLOW TEST VALVE MONITOR • • • __ ZONE INPUT • ITEST VALVE MONITOR a a a P-- RELAY OUTPUT I -, :; ;«. .1 Vt11t ,<,, p ' ,' -r NOTIFICATION APPLIANCE CIRCUIT(NAC) )OfTest .._. GENERAL HEAT DETECTOR • • • • • •• • : 4 CD ', E.,--"4 ca 1 REMOTE ANNUNCIATOR 24VDC POWER I I 'kms ur '��' REMOTE ANNUNCIATOR RS485 DATA I I • t T ;- ) E f ) Center- GENERAL SMOKE DETECTOR •• a a a a a a . rx AUDIO RISER I I • £x t;.;:.;,`,,p.Fa,rt,� 'MANUAL PULL STATION a a a a l-- - (34 SPEAKER CIRCUIT • I `” ((j !DUCT SMOKE DETECTOR a s a a • " 0 E ... r— Q,a. DOOR HOLDER CIRCUIT II [[AUXILIARY 24VDC POWER I I • % s 0.4 or, f M� ' 21 o UnitedStates Terms Sed feedback1000t'rz,..,m,._.,,...r.,. «o,,,n,.>„::.,,-,.,:.....9,.-....mac - m O I NOTE: RS232 18AWG PAIR/TWISTED,SHIELDED ' o I NON-POWER LIMITED CIRCUITS CAN NEVER SHARE PATHWAYS WITH POWER LIMITED CIRCUITS Q} Q. 0 I . , ( � „ w .v ° X_ `Isi to i= 4 ; '.tr s- } f ETAB' r t Ii , _, , I „gip _.............: ..,...,.„,., ,,,..,...,, ,.,,,..-,-,..,....,....„. f _ IE I+ EC 1 I 1!1,14_,__..._._.........r.,.._____.__.._.._.___....... _ _..._ I DRAWN 4 BY 1 ! :,i JM I CHECKED BY I 1 1 ! p p fil A p ill 1. .-.. SMOKE DETECTOR MOUNTING DETAIL -_.___-_ ,_, ____ ___..____.__-___ ___._ __. ___._.____---_______--_ _...u___ 4 , a 3 . F; I E IB T � _.,I ._._��� �. uc DETECTOR r - --'_I - 1 i1 - - i ALWAYS WITHIN 15 FT. I - 1 i DELETE EXISTING BEAM EAM 111 - , „.� - E DETECTOR REFLECTOR e;t (Or ANY SIDE'”A L) 1 ; OT DE E'EXtST vE t DEITTOR'TR'A1NSMITTER MINIMUM MINIMUM tt4INIMU".". ' MINIMUM ; 1,1 - 36 IN. ? II;'1 REV, TITLE DATE 1 I" „ 0 E I1 st Submittal 9/17/2019 CCiLING CEIL(E.G E!_Li," ;I,__ q I 1"I1,_ I t A ,,i 1114 Ill ' 1 m 'v kl t « + + + + + + + ♦ r r « I 7" J ` OU SEN ten, 1: h Ill I ACCEPTABLE J / / ) ) / ACCEPTABLE / '' REIX FIXTURE ACCEPTABLE HERE ii r - CE TABLE HERE o ✓ B ► �+ �+. a v v !tr NEVER HERE NEVER HERE NEVER HERE NEVER HERE I.....,.. ._.,.._..._......._.--- '."......_ P! iii AIR AIR SUPPLY DiF U_,ER TOP OF DETECTOR + __M_ .a. ACCEPTABLE HERE '' { I I", NOT TO SCALE) 2 IN. , am I:,IMAXIMUM ../f1 REVISIONS � 1 : . ..... "_4.: ! , PLOT DATEm_ , ll i i,a fib 0 I ,• ,1 A 49/17/2019 P P p E'� F� t i T 1 1; ., 1 I 4i i { f 1 11 i PROJECT NUMBER I SIDEWAL' I; T �, .� " ._._ ` a Ei . o iii, td I ? — .. - _ 10895b g v.FI Eft t ..,'."'°""Mr,.,.,,r'.»..w.-... ,, E .. :�' $ .---111-_.. __... -..,,..,.'""»..,. /7/7-7-------:E1- _ Ifw,, �mm FII F;: ,, �„-,___� , «. ,#_ , �, &.�- , z� �,,.,._,.�a,�� ��- _M_.. m,. �. ----.4,4,. ».....,.»»., .,.,.,.,] 0..«Y' .,F :.,.- ..{....... .,,. .tca ”` -S; 4� 4 =.x s 41 3 R a T I G A_S V '{ I ,: ;p - d A 0--i a 8 5 b L ----L14, S ^.1r Y ..,._, 1 s. 3E ,: i L._.. o- n' ror: g :,_.L.,..k...t..__._.._..�,.._..: ?;} r at C" m,,,1 ti ,y,.» ..a;,r» ,. i, L.)5�y. .,....a:� ? of 75--1.---r..., .,.._•.. 1,i I I ;i'.: __ _ M .. z - - -I ., PERMIT NUMBER if t— 1 : aff , {u §: a fI � ,II r fIli N I=; ( Itt``` I 1, „ -2.!.....:...........4r,;4:1R i TBD Typical Wiring [-� I I ._, ' _ I E ' ,., .. .,,. "!f accept ^_„ ,,,.AWL; -.wfl +.F `.; {J V - ...-,.,.. --_. __.__. ( "3?'' _1 Y,. ,...,.f k.31.''F ._.-___.., •:1 ._,_.. The detects.}; mounting ba es acct pt :,18 A :L;(0,7 Ct"t,`l 1 t, n i. —T r. i fi„_, i f 14,12 1'j S^l�"t . "} , -,t.. if , ra ................ I _-, ,,:t4„.,,,..." .„ __ ..,.,......,. ... , i i y d �{. p�y�«�-p^�. p+�ypgy and $} /�j y+��yy wire � m,x --1,1'1;,- < 1 y (1,0mm`), %P ' A `s(t, mma),a.d 14,5 2 A e,,,A(2, mrn I wire.J arrt $ lr _......_. II I�IC3te, Sizes f-IP AWG,1.OITItTI"� ,1M. rr t'� LANG 0.75rrlrr`3`) .„ DELETE EXISTINGBEAM DELETE EXISTING BEAM' � � :"" a '� ' ", IL.::::,,,,,/ .. 1 EA I �. ,,�. F referred for ease citinstallation., S e griesure Loop Conrr'oller /i ; DETECTOR TRANSMITTER DETECTOR REFLECTOR I _, ,r-. ,-,,, 1 14-4 qq .. f q i f 1'" '>""" 1 ,', i } _ THE INFORMATION ON r{IS DRAWING `I:\4,„. it,,,,,, n__ n,� - ---;,, • , a 1 -^`s ,,,.� _ 7S THE tIRIGInhA�, UNPUBLISHED WORK oata sheet for detailed whit requirement specifications. iS i .,..� IS HE ORIGINAL SYSTEMS -T-� 1 p--- ,xP t�; f^', , _ , INTEGRATION ELF P A I I i ,........r:\4I i I� i L..1 I ' - A I I - ( DISCLOSURE, REPRODUCTION, OR USE EN Standard Detect rase SIGA-SB, c _ I L I I LAN2ND FLOOR AREA OF WORK IT Y s I A a�X 4 - �..,, }"" I — CONSENT OF PTHE ERFORMANCERIOR SYSTEMS SYSTEMS e x r ( - `' ^" } �'', r1-t, : `'�, F..,,..t.„ „�. INTEGRATION ::._C tS PROHIBITED This is the bas(r. mounting base S.=R.ULe LSD -'. .»,.,.,.w .m� I , for Edwards Signature Seriesde.. I `e ore -. .,_„ �._._. __, ._ - _ Ss- P" tit . 'The ti`:.. Remote tT � ; E __ _,._„_._....__,-. SHEET TITLE e Star? _ Is LED Is supported by the w..._ ,� .._..._ DEVICE €� SLCTO-EXISTING-1T- das°d Base. �” .,,,._,.. I i r T P I. FIRE I t �wxU �. ;\ III I tdrLI:T`i.: r"e. ,«,, fc3 / , ALARM pr // Not ) ,/ EXISTING MORt ,I I r. ?T I D 1 0{T i I-1 , ,r, F I DM OUT I 1 DETECTOR TO REMAIN USE PLENUM OR RISER RATED CABLE IF REQUIRED 1 PLAN _ I?emts L§:I3 t,-,1 it- St;,.i. „261Ascrur=,[ixra.,c2�„ air(•1 GA. iP.'# DATA CC T:,.) ,, SHADED AREAS NOT IN CONTRACT 1.,7:‘,::,,,S‘ rczrn S;�-,r�f s :a^sfscsS$a.r' To 144, r.�,.�ias� SIGNING SUPERVISOR PER OAR 918-261-0015 .N, ___—-- Z - THEATER # 18 - FIRE ALARM o 1 SCALE: 1/fr= 1I-0" F-1r 1 ...4,:- 7 „„Ae:,,,,," x I : SHEET I SYSTEM DESIGN BY: _ , , Lid 4. 1' 4' 8' 16' e''" c' IA.L BROOKS ti SCALE RULER 4062 LEA c/7 i CLASS'A'LIMITED ENERGY LIC O-ISTI W .. d U IDG <