Loading...
Report U- ate' orrf g07..o wySI-A SS RD S-10 Generated by COMcheck-Web Software RECEIVED Interior Lighting and Power AUG 24 2020 :3ITY OF TIGARD Compliance Certificate BUILDING DIVISION Section 1: Project Information Energy Code: 90.1 (2016) Standard Project Title: Project Type: Alteration Construction Site: Owner/Agent: Designer/Contractor: 9020 SW Washington Square Rd Ronald Mitar Tigard,Oregon 97223 Bright Star Electric 13450 Richey Rd Boring,Oregon 97009 9719988459 ron@brightstarpdx.com Section 2: Interior Lighting and Power Calculation A B C D Area Category Floor Area Allowed Allowed Watts (ft2) Watts/ft2 (B x C) Common Space Types:Office-Open Plan 2066 0.81 1673 Total Allowed Watts= 1673 Section 3: Interior Lighting Fixture Schedule A BCD E Fixture ID : Description/Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D) Fixture Fixtures Watt. Common Space Types:Office-Open Plan(2066 sq.ft.) LED:2x4 LED Troffer: Other: 1 19 32 608 LED:6"LED Can Light: Other: 1 22 10 220 LED: Pendants:Other: 1 3 40 120 LED: EM Bug Eyes:Other: 1 2 2 4 LED: EM Exit:Other: 1 4 5 20 Total Proposed Watts= 972 Section 4: Requirements Checklist Lighting Wattage: • 1. Total proposed watts must be less than or equal to total allowed watts. Allowed Watts Proposed Watts Complies 1673 972 Passes iI 2. Exit signs 5 Watts or less per sign. Controls, Switching, and Wiring: • 3. Required automatic controls are either manual on or are controlled to automatically turn lighting on to 50%or less power. Exceptions: Public corridors,stairways, restrooms, primary building entrance areas and lobbies. l] Full automatic-on would endanger safety or security. ❑ 4. Independent manual or occupancy sensing controls for each space (remote switch with indicator allowed for safety or security). Project Title: Report date: 08/24/20 Data filename: Page 1 of 4 • O 5. Occupant sensing control in class rooms,conference/meeting rooms,and employee lunch and break rooms. Exceptions: • Spaces with multi-scene control;shop classrooms,laboratory classrooms,and preschool through 12th grade classrooms. 6. Automatic shutoff control for lighting in>5000 sq.ft buildings by time-of-day device,occupant sensor,or other automatic control. Exceptions: I] 24 hour operation lighting;patient care areas;where auto shutoff would endanger safety or security. ❑ 7. Each space enclosed by ceiling height partitions has at least one control device to control the general lighting. Each manual device is readily accessible and located so the occupants can see the controlled lighting. 8. All controlled general lighting enclosed by ceiling height partitions has at least one control step between 30%and 70%(inclusive)of full lighting power in addition to all off. Exceptions: LI Lights in corridors,electrical/mechanical rooms, public lobbies,restrooms,stairways,and storage rooms. LI Spaces with only one luminaire with rated input power less than 100 W. I] Spaces types with lighting power allowance of less than 0.6 W/ft2. ❑ 9. All controlled general lighting enclosed by ceiling height partitions in the following space types has an occupant sensor or a timer switch installed that automatically turns lighting off within 30 minutes of all occupants leaving the space:Classrooms and lecture halls, conference, meeting,and training rooms,employee lunch and break rooms,storage and supply rooms between 50 ft2 and 1000 ft2, rooms used for document copying and printing,office spaces up to 250 ft2,restrooms,and dressing, locker,and fitting rooms. Exceptions: 1] Spaces with multi-scene control systems,shop and laboratory classrooms, spaces where an automatic shutoff would endanger the safety or security of the room or building occupant(s), and lighting required for 24-hour operation. • 10.All controlled general lighting enclosed by ceiling height partitions in spaces not included in the above requirement, has a control device that is activated either manually by an occupant or automatically by an occupancy sensor.Each control device controls a maximum of 2500 ft2 area for a space 10,000 ft2 or less and a maximum of 10,000 ft2 area for a space greater than 10,000 ft2.The occupant is able to override any time-of-day scheduled shutoff control for no more than two hours. Exceptions: I] Remote locations subject to safety or security concerns when the remote control device has an indicator pilot light and the light is clearly labeled to identify the controlled lighting. • 11.Primary sidelighted areas>=250 ft2 have general lighting lamps independently controlled by at least one multilevel photocontrol. Exceptions: CI Areas where the top of existing adjacent structures are twice as high above the windows as their distance away from the windows. ▪ Areas where the sidelighting effective aperture is less than 0.1 (10%). O Retail spaces. D 12.Toplighting areas>900 ft2 have general lighting lamps independently controlled by at least one multilevel photocontrol. Exceptions: I] Areas where existing adjacent structures or natural objects block direct beam sunlight for more than 1500 daytime hours per year. ▪ Areas where the skylight effective aperture(EA)is less than 0.006(0.6%). • Buildings in climate zone 8 with daylight areas<1,500 ft2 in an enclosed space. • 13.Parking garage lighting is controlled to automatically reduce lighting power of each luminaire by at least 30%when the lighting zone(no larger than 3600 ft2) is vacant for no more than 30 minutes. Exceptions: Project Title: Report date: 08/24/20 Data filename: Page 2 of 4 ] Daylight transitions zones and ramps without parking. ❑ Applications using HID of 150 watts or less or Induction lamps. • 14.Parking garage daylight transition zone lighting is separately controlled by a device that automatically turns lighting on during daylight hours and off at sunset. ❑ 15.Parking garage luminaires within 20 ft of any perimeter wall structure that have 40%or more net opening to daylight have capability to automatically reduce power in response to daylight. Exceptions: I] Daylight transitions zones and ramps without parking. • 16.Guestrooms have control device(s)at the entry door that control all permanent luminaires and switched receptacles,except those in the bathroom(s).Suites have control(s)meeting these requirements at the entry to each room or at the primary entry to the suite. Bathrooms have a control device installed to automatically turn off lighting within 60 minutes of room vacancy. Bathroom night lighting does not exceed 5 watts. o 17.Separate control device for display/accent lighting,case lighting,task lighting, nonvisual lighting,lighting for sale,and demonstration lighting. • 18.Lighting control devices and control systems are tested to ensure that control hardware and software are calibrated,adjusted, programmed,and in proper working condition. When occupant sensors,time switches,programmable schedule controls,or photosensors are installed,at a minimum,the following procedures have been performed: a.Confirm that the placement,sensitivity and time-out adjustments for occupant sensors yield acceptable performance. b.Confirm that the time switches and programmable schedule controls are programmed to turn the lights off. c.Confirm that photosensor controls reduce electric light levels based on the amount of usable daylight in the space. Construction documents identify the party responsible for the functional testing.The party responsible for the functional testing is not directly involved in the project. Voltage And Power: • 19.Feeder conductors have been designed for a maximum voltage drop of 2 percent.> Exceptions: ] Dedicated to emergency services. ] 20.Branch circuit conductors have been designed for a maximum voltage drop of 3 percent.> Exceptions: ] Dedicated to emergency services. o 21 Voltage drop analysis must include the parts of the existing system extending to the point of electrical supply at the transformer or service equipment entrance. ▪ 22.At least 50%of all 125 volt 15-and 20-Ampere receptacles in private/open offices or computer classrooms are controlled by an automatic control device that operates on: a.a time-of-day operated control device that turns receptacles off at specific programmed times,or b.an occupant sensor that shall turn receptacles off within 30 minutes of all occupants leaving a space, or c.a signal from another control or alarm system that indicates the area is unoccupied. Exceptions: ] Receptacles for equipment requiring 24 hour operation. O Spaces where safety or security concerns would be compromised. Section 5: Compliance Statement Compliance Statement: The proposed lighting alteration project represented in this document is consistent with the building plans, specifications and other calculations submitted with this permit application.The proposed lighting alteration project has been designed to meet the 90.1 (2016)Standard, Chapter 8, requirements in COMcheck-Web and to comply with the mandatory requirements in the Requirements Checklist. Name-Title Signature Date Section 5: Post Construction Compliance Statement Project Title: Report date: 08/24/20 Data filename: Page 3 of 4 Record Drawings and Operating and Maintenance Manuals: O 1. Construction documents with record drawings and operating and maintenance manuals provided to the owner. Lighting Designer or Contractor Name Signature Date Project Title: Report date: 08/24/20 Data filename: Page 4 of 4