Loading...
Report (5) I zoao- cce, (0�8o Sw Va .� HOneyW7ie f , VisionPRO® 8000 with RedLINKTM TrIzC; p�G 1 ,�� SUBMITTAL SHEET APPLICATION Cy J Electrical Ratings(for VisionPRO and Equipment Interface �Ot it Module): RedLINK VisionPRO is a 7-Day programmable thermostat with auto Terminal Voltage Max.Current changeover that is designed for single stage and multistage control (50/60 Hz) Rating of conventional and heat pump equipment such as rooftop units and W-Oi0 t 6 to 30 VAC 1.o0A split systems in residential and commercial applications.RedLINK and 750 mVDC VisionPRO can be used with or without an equipment interface module. The thermostat controls up to 3 heat/4 cool conventional systems Y(cooling) 18 to 30 VAC 1.00A and up to 4 heat/2 cool heat pump systems.The thermostat controls G(fan) 18 to 30 VAC 0.50A humidification,dehumidification,ventilation,an economizer and a W2-Aux 1(heating) 18 to 30 VAC 0.60A lighting panel.Universal sensor inputs are used with remote indoor air W3-Aux 2(heating) 18 to 30 VAC 0.60A temperature sensor(s),an outdoor air temperature sensor,a discharge air temperature sensor,a return air temperature sensor,an occupancy Y2(cooling) 18 to 30 VAC 0.60A sensor for remote setback and dry contact devices for displaying alerts. A-LJA(Output) 18 to 30 VAC 1.00A • The thermostat is equipped with a touchscreen display with a 2 line (Ut,Ut),(U2,U2),(U3,U3) 30 VAC max. 0.50A message center. Power Consumption of TH8321/TH8320fTH8110Thermostat: Backlight on:1.44 VA • Provides a microSD card port to upload Dealer Information,Custom Backlight off:1.32 VA Reminders,Custom Event Schedules,Holiday Schedule and Software Updates and to download Data Logs. Power Consumption of Equipment Interface Module:2.0 VA • Provides remote access to the thermostat when used with the RedLINK Communication: RedLINK Internet Frequency:900 Mhz frequency range gateway. • Provides control using optional remote temperature and humidity Re-Sync Time:RedLINK devices re-establish communication sensors. within 6 minutes after AC power resumes. • • Thermostat integrates with the Niagara-AX framework. Temperature Setting Range: Heating:40 to 90°F(4.5 to 32°C) SPECIFICATIONS Cooling:50 to 99°F(10 to 37°C) Temperature Sensor Accuracy: Terminal Designations: t 1.5°F at 70°F(0.75°C at 21.0°C) Equipment Interface Module:R,RC,RH,C,W-OB,W2-AUX 1,W3- Humidification Setting Range: 10%to 60%RH AUX 2,Y,Y2,G,A-UA,U1 Ut,U2 U2,U3 U3,S1 S1,S2 S2,S3 S3,S4 S4,A,B,C,D Dehumidification Setting Range:40%to 80%RH TH8321 Thermostat:R,RC,C,W-O/B,W2-AUX/E,Y,Y2,G,A-UA,K, Humidity Display Range:0%to 99% U1 U1,S1 S1 Humidity Sensor Accuracy: TH8320 Thermostat:R,RC,C,W-O/B,W2-AUX/E,Y,Y2,G,A-UA,K, ±5%RH from 30%to 50%RH at 75°F(24°C) S1 S1 Cool Indication: TH8110 Thermostat:R,RC,C,W-O/B,Y,G,K,S1 S1 Displays"Cool On"when the thermostat turns the cooling on. Job Name Model(s) Oty. TH8321R1001 0 Engineer TH8320111003 0 Mechanical Contractor TH8110R1008 0 THM5421R1021 ❑ Contractor's P.O.No. Approval Representative Service Notes Tag No. III HI II III III POI I II 33-00016-01 Ink Cl SPECIFICATIONS (CONTINUED) 11mnue per mothat77°F(25°C).12 minutes per month over the operating ambient temperature range. Heat Indication: • Displays"Heat On"when the thermostat turns the heating on. Mounting Means: Thermostat mounts directly on the wall in the living space using ▪ Auxiliary Heat Indication: mounting screws and anchors provided.Fits a horizontal 2 x 4 , Displays"Aux Heat On"when the thermostat turns the auxiliary heat on. in.junction box.Use a cover plate and its mounting bracket to mount the thermostat onto a vertical 2 x 4 in.junction box. Interstage Differential: Equipment Interface Module(EIM)mounts on HVAC equipment Comfort:The thermostat keeps the indoor temperature within 1 degree of the or on a wall in the equipment room. setpoint(droop less control).The thermostat turns on stage 2 when the capacity on stage 1 reaches 90%. When the interstage differential is set to 1.0 or higher,the thermostat stages - the equipment based on how far the indoor temperature is from the setpoint. Product Part Number Operating Ambient Operating Shipping Physical Dimensions in Color(s) Temperature Relative Temperature in.(mm) Humidity Thermostat TH8321 R1001 32 to 120°F 5%to 90% -20 to 120°F 4-15/16 x 4-5/8 x 1-1/6 Arctic White (0 to 48.9°C) Non-Condensing (-28.9 to 48.9°C) (126 x 118 x 29) TH8320R1003 32 to 120°F 5%to 90% -20 to 120°F 4-15/16 x 4-5/8 x 1-1/8 Arctic White (0 to 48.9°C) Non-Condensing (-28.9 to 48.9°C) (126 x 118 x 29) — TH8110R1008 32 to 120°F 5%to 90% -20 to 120°F 4-15/16 x 4-5/8 x 1-1/8 Arctic White (0 to 48.9°C) Non-Condensing (-28.9 to 48.9°C) (126 x 118 x 29) Equipment YTHM5421R1010 -40 to 165°F 5%to 95% -20 to 165°F 9-11/32 x 4-53/64 x 1-19/32 Gray Interlace THM5421 R1021 (-40 to 73.9°C) Non-Condensing (-28.9 to 73.9°C) (237 x 123 x 41) Module Dimensions of thermostat in in.(mm). Dimensions of VisionPRO cover Dimensions of Equipment Interface plate in in.(mm). Module in in.(mm). 16-5/3256) 453/64(123) 1-41) -lb" .4-25/32(20) ICI t 1 \° o/ 8-7/8 4-5/8 5-3/4 (225) (118) (146) 1 Q—'1-1/2 0 0 (38) I 9-11/32 (237) /o o\ I [- 445/18(126) 1 1dI8(2� 1.._ / M34258 C I ° n 0 IN G TS M33331 B B Q 36116(84) M34521 Honeywell Automation and Control Solutions Honeywell International Inc. 1985 Douglas Drive North ®U.S.Registered Trademark Golden Valley, MN 55422 C2013 Honeywell International Inc. 33-00016-01 M.S. 10-13 customer.honeywell.com Printed in United States