Report (3) . ��8o ski./ va Qzr4s s`t 0MicroMet1 Date: Weights: Units: Part Number: 2/25/2019 811bs/36.74kg MB-GP20CA-D2DH Submitted To: mjones@airefco.com Job: Notes: Mixing Box - 1600-2400 CFM - Size 23.5" X 23.5" X 23.5", The Cube-Generic Ultra Low Leak Fault Detection & Diagnostic Controls - Honeywell Jade W7220 Controller, Adjustable Dry Bulb Sensor, Honeywell Actuator, Galvanized Finish, Barometric Relief NOT Included. Field Fabrication of a Transition May Be Required E C 4 der F,.. AUu 1 8 2020 t� EVIf r1' r♦ lA [ram,.o �iVf v�hi+V Actuators j A • 'tit. 4000111111111111111111Sib. ti Housing ,�� ��1�'- ^ � \with W7220 �� ,��`\\, ..-'.;- , Controller E • 11401 101*-' I C Size 2n Aii ti"'-'''''''. ;1770 shown. . - < ill' B Access Door D to Controls 7 Approximate static pressure drop through each damper in inches w.g. 400 CFM 800 CFM 1,200 CFM 1,600 CFM 2,000 CFM 2,400 CFM 0.02 0.05 0,10 0.14 0.25 0.33 A B C D E 23.50 23.50 23.50 18.00 18.00 The Information contained in this drawing is the sole property of Micrometl Corporation.Any reproduction in part or whole without the written permission of Micrometl Corporation is prohibited. Inidanapolis_3035 N.Shadeland Ave.,Indianapolis,IN 46226_800.MMC.HVAC..Sparks_905 Southern Way..Sparks,NV 89431_800.884.4MMC..Longview 201 Kodak Blvd.,Longview,TX 75602_903.248.4800 Q MicroMetl Date: Weights: Units: Part Number: 2/25/2019 811bS/36.74kg MB-GP20CA-D2DH Submitted To: mjones@airefco.com Job: Notes: Mixing Box- 1600-2400 CFM-Size 23.5"X 23.5"X 23.5",The Cube-Generic Ultra Low Leak Fault Detection&Diagnostic Controls-Honeywell Jade W7220 Controller,Adjustable Dry Bulb Sensor,Honeywell Actuator,Galvanized Finish, Barometric Relief NOT Included.Field Fabrication of a Transition May Be Required Compliant Economizer: 1. Title 24:Economizers meet California Energy Commission Title 24-2013/2016 prescriptive section 140.4(damper leakage etc.),and mandatory section 120.2.i for Fault Detection and Diagnostic controls(JADE HJW10). 2. ASHRAE 90.1:Economizers meet ASHRAE 90.1-2013/2016 damper leakage requirements,and meet 2016 Fault Detection and Diagnosis requirements. 3. IECC:Economizers meet IECC 2012,IECC 2015,and IECC 2018 for outside air,return air,and relief damper(when provided)leakage requirements,and IECC 2015 and IECC 2018 for Fault Detection and Diagnostic requirements.Note:IECC 2015 and IECC 2018 requires differential return air sensor,which is included in some models(i.e.D2XH)and must be ordered separately on others(i.e.D2DH,D2ZH). 4. AMCA:Outside air and return air(volume)dampers are AMCA Class 1A rated at 1"w.g.Refer to MicroMetl NS1 catalog sheet on web site for details.Relief air dampers(when provided)are also AMCA rated. Refer to GR1 series catalog sheet on web site for details. Features; • Outside air damper and return damper each have a separate actuator to allow for easier relocation of dampers on mixing box • Gear driven design for trouble-free operation,eliminating slippage and binding associated with standard linkage. p pr. AIR • Internally insulated t • All harnesses needed are provided. • • Barometric relief damper available. Notes: MicroMetl Corporation certifies that the models 1. Control systems include Honeywell W7220 JADE controller,supply mixed air temperature sensor,OA sensor in description,spring-return actuator cat and NSt shown separate actuator on return damper(some include differential return sensor as noted). beret are licensed to on OA damper,and a Pe hear the AMCA Seal. 2. JADE W7220 controller is factory mounted on mixing box. The ratings shown are based on tests and 3. Mixed(supply)air sensor is field installed in indoor blower fan section. procedures performed 4. Differential return sensor(included in"-D2XH"and"-D2ZH"models or can be ordered separatelyMicroMetl Part No.9901-2022-DIFF)is field in accordance with - AMCA Publication installed in return duct. 511 and comply with requirements of the 5. ASHRAE,IECC,and Title 24 require the economizer controller be capable of reporting faults to a fault management application accessible by AMCA Certified day-to-day operating or service personnel,or annunciated locallyon zone thermostats or in some codes other devices are acceptable_Refer to Ratings Programs. P The AMCA Certified applicable code requirements and to MicroMetl instructions for suggestions. Ratings Seal applies to Air Leakage and Air Performance ratings. The Information contained in this drawing is the sole property of Micrometl Corporation.Any reproduction in part or whole without the written permission of Micrometl Corporation is prohibited. Indianapolis_3035 N.Shadeland Ave.,Indianapolis,IN 46226_800.MMC.HVAC••Sparks 905 Southern Way,Sparks,NV 89431_800.884.4MMC••Langview_201 Kodak Blvd.,Longview,TX 75602_903.248.4800