Loading...
Plans RECEIVED APR 3 2020 Cry OF TIGARD BijiLDINO DIVISION Building Plans for City of Tigard Building Permit Application Customer: The Fountains at Summerfield condominiums HOA 15685 SW 116th Ave., #105 Tigard, OR 97224 Contact- Paul Brock, 858-212-9105, pbrock987@gmail.com OFFICE COPY Contractor: Jon Erickson, 503-730-9220 CITY OF TIGARD jon.eveniobs@gmail.com CCB 162397 REVIEWED FOR CJI) i COMPLIANCE Approved: ] Scope of Work— Repair Decks OTC: [ I • Replace perimeter joists with PT • Repair joist and soffit dry rot Permit #: aupapap— - f Address: j %,r ) 1 • Replace 42" guardrail and infill to comply with Suite #: IBC multi-family code By: Date: .sc-c) • VALIDITY OF PERMIT THE ISSUANCE OF A PERMIT File Name: Fountains Deck Permit Plans REVISED.pptx BASED ON CON� TR UCT ION DOCUMEN i.S P.M) OTHER DATA SHALL NOT Pr-EVENT THE CODE OFFICIAL SRO'.A REQUIRING, THE E CORRECTION OF ERRORS. OSSC 105.4 3/19/20 Fountains at Summerfield - Deck Building Plans 1 Typical Deck Construction and Size — 102 SF Brick Cot, 114.5" 15x9 Imbedded 6x6 PT L] 4x4 PT Posts 2 x 8 PT blocking between joists attached with Three 16D 3-1/2"n HDG ><----->< Ref: 2014 Oregon Structural 43" 15" 56.5" Specialty Code—Table 2304.9.1-29 2"x8"Joists 16" OC Blocking supports Simpson Rim joist attached to Tension Ties DTT2Z.Two lateral joists with / DTT2Z brackets required for Three 16D 3-1/2"n HDG h posts in this position. See Beam ' 6"x10" Simpson Wood Connection Ref: 2014 Oregon Connectors 2018-18 Deck Structural Specialty ^ Tension Ties—page 337 Code—Table ai N 2304.9.1-29 '- House—Brick exterior 43" Scale—12"/increment V I J 3/19/20 Fountains at Summerfield - Deck Building Plans 2 Water Penetration Remediation — Cross Section Posts—4x4 PT Flashing 2" x 3" Resurfacing material 3/4" exterior plywood decking La •o 00 x N Hardi-plank Fascia 9.25" x .25". Applied with exterior adhesive and secured with post bolts. Wicking protection for soffit provided by 3/" extension. Pre-paint before adding flashing %2" plywood soffit Scale—1" increment 111111111 3/19/20 Fountains at Summerfield - Deck Building Plans 3 Guard Rail Post — Simpson Tension Ties Posts-4x4 PT "� Simpson DDT2Z . �\\ \\\\\\\\\ Attach D lateral joist with `" to 1S" screws : Sy9 Y" x 6" Machine Bolt - DTT2Z supports 1800 lb. HDG with nuts and "" tension load. Meets IBC washers Code for multi-family deck v, 00 'o guardrails. N E Refer to attached Simpson 2 catalog- Deck Tension Ties Lateral Joist page 337 4 \` �� 111 Also refer to Simpson code compliant Guardrail Post Connection bulletin T-C-GRDRLPST17 Scale- 1" increment 3/19/20 Fountains at Summerfield - Deck Building Plans 4 Typical Guardrail and Infill Section — 50" max. between posts Simpson Strong Drive A Wide Screw SDWS 4", Railing 2 x 4 TKC 2 3/8"TL. Two per Cap Rail—Trex veta4, end,three in mid span 1" x 5.5" 1.1* attached to Railing with exterior adhesive. Zn n Railing Su:01.t 1 a 2x4 TKC o a 0o Attached 1— v Railing and Installation of Posts with v balasters and rails adhesive and per mfg installation Simpson instructions. Strong Drive Wide Screw SDWS 4", 2 3/8"TL. Railing 2 x 4 TKC Railing Infill DecKorator aluminum Y _ 2.75" space balaster%" x 32". Spacing 3.75" DecKorator Scale 1" increments CodeCompliance Research Report i l l l l l l l l j l l i CCRR-0161 3/19/20 Fountains at Summerfield - Deck Building Plans 5 of 5