Loading...
Plans (52) M EC2018-00288 - 1E-- O 1 l 5.--(,.s--- s w gave.c.-4c @lr,: 0 (2 )2 RECEIVED APIA 2i 2018 N - - CITY OF TIGARD I _ _.; I BUILDING DIVISION 0 oo ; APPAREL 0 KEY NOTES: Q STOCK NEW GENERAL NOTES: I MEZZANINE ° 1. EXISTING PACKAGED ROOFTOP TO REMAIN AND BE REUSED. SEE 'M1.1' SHEETS FOR NEW WORK. g o _ `Q' '� I j 201 ©(TYP) V. A. EQUIPMENT AND DUCTWORK SHOWN DARK AND DASHED TO BE REMOVED. ANY EQUIPMENT 2. EXISTING EQUIPMENT TO REMAIN. c j c AND DUCTWORK SHOWN LIGHTER AND SOLID TO REMAIN. REMOVE AND DISCARD ONLY THE HVAC EQUIPMENT AND DUCTWORK INDICATED. ALL OTHER HVAC EQUIPMENT AND DUCTWORK 1°„ 1 _ I 1°„�-\, \�/E 3. REMOVE AND DISCARD EXISTING EQUIPMENT, DUCTWORK AND ALL ASSOCIATED ACCESSORIES. CAP - ,nTO REMAIN AND BE REUSED. I (-1h, I I 16'10 IL 14; I I UL I 1i7 fid I I I E a ALL ROOF PENETRATIONS WATERTIGHT PER ROOF MANUFACTURER'S ROOF WARRANTY AND y INSTRUCTIONS. B. ALL EQUIPMENT AND DUCTWORK DISCARDED SHALL BE LEGALLY DISPOSED OF TO AN -- ora ax.u OFF-SITE LOCATION BY THIS CONTRACTOR. OFFSET DROP TIGHT 4 '�" TO WALL 4. REMOVE & DISCARD ONLY ENOUGH DUCTWORK TO RECONNECT TO NEW. SEE M1.1' PLANS FOR W ° C. ALL PATCHING OF ROOF SHALL BE COMPLETED IN ACCORDANCE WITH EXISTING ROOFINGn O NEW WORK. a 22 � FROM SYSTEM REQUIREMENTS AND ROOFING MANUFACTURER'S INSTRUCTIONS AND WARRANTIES. AC-18A- ' a 5. EXISTING REGISTER, DIFFUSER, OR GRILLE TO REMAIN. SEE M1.1 SHEETS FOR AIRFLOW VALUES. D. REPLACE ALL EXISTING CONCEALED FLEXIBLE DUCTWORK SECTIONS IN AREAS WITH 16. CAP, PATCH AND SEAL EXISTING DUCTWORK. SMOOTH AND PRIME FOR PAINTING BY PAINT REPLACED CEILINGS WITH NEW FLEX DUCT SECTIONS. OLD FLEX DUCT SECTIONS SHALL BE CONTRACTOR. REMOVED AND DISCARDED. E. ALL DUCTWORK, INSULATION, EQUIPMENT AND PIPING SIZES ARE TO BE INCHES UNLESS il 7. REMOVE AND DISCARD EXISTING THERMOSTAT, TEMP SENSOR OR DUCT DETECTOR AND ALL NOTED OTHERWISE. ` DEMOLITION H\/1\C PLAN - ALE IV1EZZANINE ASSOCIATED CONTROL WIRING NOT REUSED. SEE 'M1.1' SHEETS AND TM' CONTROL DRAWINGS Ne'A FOR NEW WORK. +11° F. THE MECHANICAL CONTRACTOR SHALL REMOVE AND DISCARD OFF-SITE ALL ABANDONED -, SCALE: 1/8"=t-0" 8. EXISTING THERMOSTAT OR TEMPERATURE SENSOR TO REMAIN. DUCTWORK, HVAC EQUIPMENT AND HANGERS, BOTH CONCEALED AND NON-CONCEALED, NORTH THROUGHOUT THE BUILDING. MECHANICAL CONTRACTOR SHALL FIELD VERIFY ALL ABANDONED DUCTWORK AND HVAC EQUIPMENT PRIOR TO BID. 9. EXISTING SUPPLY DIFFUSER, SIDEWALL REGISTER, RETURN OR EXHAUST GRILLE TO BE REMOVED I(>' AND DISCARDED. SEE 'M1.1' SHEETS FOR ALL NEW WORK. G. MECHANICAL CONTRACTOR TO REMOVE AND DISCARD ALL EXISTING DUCTBOARD DUCTWORK IN THE CONTRACT AREA. 10. REMOVE AND DISCARD ALL DUCTWORK AND EQUIPMENT SHOWN DARK AND DASHED (TYP). 4re- (I) 11. EXISTING CO2 SENSOR TO REMAIN. El8 1919. 1"} 19. 20 E* FRED MEYER7 003 5 , , TIGARD PN : 701-00375-06 11565 SW Pacific Hwy. Tigard, OR, 97223 i \ 0 0 O , 1\------: _-- ----- ------ _ 2018 Go-Fast Remodel �. ,� '` � ! ECI Job# 73T02 .. ° ° V, . v -.--- R __, Fred Meyei ____ _ ________ ••i \ s• I :io 41 20X12 -�MJ 0 APPAREL ' DOWN FROM - •, - RECEIVING o — MEZZANINE STOCKROOM 181 (nP) (�, � I 151 TYP) FRED MEYER 4 STORES, INC :1 I 1Ali 10 \ I / Ali Ali \ 1i 1°"o� \ Ii �___ 4 I ��� 18"01 I �fi"� I Q . 14-0 .I III 17"0 I I L / 9.12.1 :_______ 1 , 3800 SE 22nd Ave —1—.1 ' iii L 1 - --i-- , 0- ii O 111 - - Portland, Oregon j . 1 [ 1 I - --- 97202 7-- - PRODUCEOPP/ E PREP I I 22 I" i Oak a MA 177 I � — -6 ,_ 4 V I I (E)15"o ,' r/ / , RobLaw *.... f} DAIRY u (E)2o � , 503.797.3519 COOLER0 0 4 FrIL ,--, ) N >N1Q. i 1 176 1j —�— —� - V. � fredme er.com O� ®1 — nl ,. , - O 1 - I -I F i _ 0(TYP) 0 ) _ I2"� (ND KEY PLAN 1 . ` O i„I._— These drawings are the property of ArchiTrout U //`\\ � � ;. I Design &Architecture, LLC, and are not to be used z - --__ j I I or reproduced in any manner without prior written J ��0 00000000/ N permission. taH,1____ _ ' i 0 2077 _ _ __. ` Ni i r 11 Permit Set I ,/ O(nP) , i ________ _, 02 . 22 . 2018 , __ // ._ , 1 T , 7 _ ------.=- 1 / O '� REVISIONS: ice. t i � /i -- r�O ( �� -111- = I it _t__J i ,� H O/ — I I 1 IH , ._ />: 19-0 / s 30"x1 1" , / - I SHEET TITLE: I � �. `I � 1/ / 7—), „ ` i i i I � /I I i �j � n � 12 � p. r , , , —� _ I - n 120 T� AW*1- I DEMOLITION �{ l 26°' 0 1 I I HVAC PLAN - �1, L ` (TYP) TYP ) #i ( )Q ' nP AREA 3 /\ Imo; } I I : m.1 . c -EXSTI Li I � ` co h I1 I I r � ;1 , �� IIIup ,. -1 7- 1 4 - . 4� 1� DRAWN BY: JJR 2 0 PLAN DEMOLITION HVAC - AREA 3 CHECKED BY: CLM W., SCALE: 1 /8" = 1 '-0" NORTH PRELIMINARY NOT FOR CONSTRUCTION PERMIT SET: 02/22/2018 • 3 0 18 19 1 . 1 19. 4 20 @---1} 22 N N 00 1 I r+ 97 -1- 7 ...,,,_ v,, ,, , (NP)i i 4- 10 {TYP} u a., i, ;i , EXISTING . , �, m ; , il AC EI---1 I�II�1lvviVI1111111i 111!' •• , ° :1:4 z ■■ N g ,ti , i 0 f O 18 ) ` � I 52"x24" (lj ■■ ` w r iii eit u, 1 TYP .� cri 'o IJ1 gl ..,.! 111111111111I1411m!,,. �\ N Q I ,_,...1-- � �� �_ r ,� I o o ___L __ , ME RE Oho co4 N MEME 30"x10"1 1 III III 6j ' I I1 1 111111 \ .w // O{TYP) - � 12": - IL.,, W o I _ Ca - lai - 12w� "D-Wilk- iii a. h \ I �-- �/ I 1 r =i - I \ ! / # TYP --f 44 \ -/- Pi 1 • -- / (4. / H .AI 'ilkIV // , 777 Es ill 1 El--1 '4--4----1--'- 11+ fl 1 \41°. (TYP)Q 1 #. - 10rs 6� 4� ---2--i ed - -- /7 - - 1 t i i II -1` I '�r._L j 1 18" I� �Ett � L_ O TYP) / /51D-jAlii, -011-‘H� :r -4 -±r-, /\ I \ leI _ \T. 2"0 1 1 • I I _ r]Nf (Typo (E -._ . / � .,� , FRED MEYER 0 � � 11 im. E711 I 1 1 I II - - -, ._ ..._ AC-18,25,37 CO2S " . --� � =MI MINIM II isri, I — !Ir - 1 TIGARD % c) ,&. - , %I- / / / . F I 11 _ � Q X , I .■ .■ P N : 70100375-06 .' APPAREL , . .. �� .�. r -� s i�/ 1 �,/ / I , I--711 1155I / - 1 11565 SW Pacific Hwy. LEI- Ili HI ( / ' _. ----, , 1, , , , H H, ] �- \ Q . . Tigard, 0R, 97223 1 ` r� ,! oh_41,, �' II 12:01-A - , I i i 11 i` 16'99�C\\ "n i i 18" i ,� v �. 1 12 � i � � .H I V= -0 `)7Pr- p -lee -� I � 12 � 7 � r i 1-----jr ,�__1401 i. — �' 1 TYP 1 - -r1 '� - jeflit, H 2018 Go-Fast Remodel I, i ifj Lit1 --� O{ } 1 I I r I —1 ' �� iiii . 40 •• / I t -----, � � � I � ___�_. � � i ECI Job# 73T02 � 1 I Ili4,- 4 I % I FROM AC-17 1 i. 1 - 1 1 _, L �i - 7_ r, 2 O{TYP} r 1! L _1 ` i 30x10 4 11 i C:''' FMeyerd ,� \\` 'mo -----� / 1 FROM AC-18 , /, I 1 11 1 1 1 I � 61 I 1 III II I •I 1 \ / <.....„ , E1 I FRED MEYER F 1 r 1 ,r, _ .._,1001I I1 /28x16" _ — �, \ _,---- I 120 ; �TYP} 1 ; 1 L , 1 STORES, INC r -- aill / - - - - O{TYP) f ( 1 3800 SE 22nd Ave 1uhl, . { } - Q TYP}rO TYP N �12" _ n Portland Oregon 1 /18 x1 s ___ fin r 1-71 �- .■ _- I 97202 I 1 I H I �-- 111 1 ' � � ■■ C12 � �� l � ��- 1 i H (E)22"OI � I .--_ 7_ I ,-- ..,4,--,, I , 30"x1o" Il,lll;li APPAREL EXISTING ___.__1 Rob Law ■■ � EX155 — - i Ii� Q 503.797.3519 f ` potk > N 12"0-1. In111111111I111111111!,.,. I orT" : ;Y .. _ cv\ ;' rIIII'I,11 ►�� 1 f red m eye r.co m f � L 1 1 ti .rs. \i_ ' c> 1 1[ h‹.1 rilj. crYP)0 -GL 32 x24 - xl6 - - - I Fi - I (E)18 0 I These drawings are the property of ArchiTrout 0 Design &Architecture, LLC, and are not to be usedI 1 ,-,, ,_.„, i . ..... ` or reproduced in any manner without prior written permission. KEY NOTES: © zoic NEW GENERAL NOTES: DEMOLITION HVAC PLAN - AREA 6 Permit Set A. EQUIPMENT AND DUCTWORK SHOWN DARK AND DASHED TO BE REMOVED. ANY EQUIPMENT ' 1. EXISTING PACKAGED ROOFTOP TO REMAIN AND BE REUSED. SEE 'M1.1' SHEETS FOR NEW WORK. AND DUCTWORK SHOWN LIGHTER AND SOLID TO REMAIN. REMOVE AND DISCARD ONLY THE , SCALE: 1 /8" = 1 '-0" 02 . 2 2 . 20 18 HVAC EQUIPMENT AND DUCTWORK INDICATED. ALL OTHER HVAC EQUIPMENT AND DUCTWORK NORTH 2. EXISTING EQUIPMENT TO REMAIN. TO REMAIN AND BE REUSED. 3. REMOVE AND DISCARD EXISTING EQUIPMENT, DUCTWORK AND ALL ASSOCIATED ACCESSORIES. CAP REVISIONS: B. ALL EQUIPMENT AND DUCTWORK DISCARDED SHALL BE LEGALLY DISPOSED OF TO AN ALL ROOF PENETRATIONS WATERTIGHT PER ROOF MANUFACTURER'S ROOF WARRANTY AND OFF-SITE LOCATION BY THIS CONTRACTOR. INSTRUCTIONS. C. ALL PATCHING OF ROOF SHALL BE COMPLETED IN ACCORDANCE WITH EXISTING ROOFING 4. REMOVE & DISCARD ONLY ENOUGH DUCTWORK TO RECONNECT TO NEW. SEE 'M1.1' PLANS FOR SHEET TITLE: SYSTEM REQUIREMENTS AND ROOFING MANUFACTURER'S INSTRUCTIONS AND WARRANTIES. IN1 BM NEW WORK. DEMOLITION D. REPLACE ALL EXISTING CONCEALED FLEXIBLE DUCTWORK SECTIONS IN AREAS WITH 5. EXISTING REGISTER, DIFFUSER, OR GRILLE TO REMAIN. SEE 'M1.1' SHEETS FOR AIRFLOW VALUES. REPLACED CEILINGS WITH NEW FLEX DUCT SECTIONS. OLD FLEX DUCT SECTIONS SHALL BEk i.,.. HVAC PLAN REMOVED AND DISCARDED. 3-- 6. CAP, PATCH AND SEAL EXISTING DUCTWORK. SMOOTH AND PRIME FOR PAINTING BY PAINT E. ALL DUCTWORK, INSULATION, EQUIPMENT AND PIPING SIZES ARE TO BE INCHES UNLESS o CONTRACTOR. AREA 6 NOTED OTHERWISE. 7. REMOVE AND DISCARD EXISTING THERMOSTAT, TEMP SENSOR OR DUCT DETECTOR AND ALL F. THE MECHANICAL CONTRACTOR SHALL REMOVE AND DISCARD OFF-SITE ALL ABANDONED ° ASSOCIATED CONTROL WIRING NOT REUSED. SEE 'M1.1' SHEETS AND 'EM' CONTROL DRAWINGS • .,,� FOR NEW WORK. DRAWN BY: JJR DUCTWORK, HVAC EQUIPMENT AND HANGERS, BOTH CONCEALED AND NON-CONCEALED, THROUGHOUT THE BUILDING. MECHANICAL CONTRACTOR SHALL FIELD VERIFY ALL ABANDONED 8. EXISTING THERMOSTAT OR TEMPERATURE SENSOR TO REMAIN. DUCTWORK AND HVAC EQUIPMENT PRIOR TO BID. CHECKED BY: CLM KEY PLAN 9. EXISTING SUPPLY DIFFUSER, SIDEWALL REGISTER, RETURN OR EXHAUST GRILLE TO BE REMOVED G. MECHANICAL CONTRACTOR TO REMOVE AND DISCARD ALL EXISTING DUCTBOARD DUCTWORK -- -� - IN THE CONTRACT AREA. AND DISCARDED. SEE 'M1.1' SHEETS FOR ALL NEW WORK. PRELIMINARY NOT FOR CONSTRUCTION PERMIT SET. 02/22/2018 10. REMOVE AND DISCARD ALL DUCTWORK AND EQUIPMENT SHOWN DARK AND DASHED {TYP}. MD1 . 1 • 6 11. EXISTING CO2 SENSOR TO REMAIN. 0 0 , F j 1 1 ,., r ra ch tk 0 .� /Um MIMEO ' VP a) • 3K" C , ilir Lii' , 1 . 0 - E j c' W ao l , , ( ,_ Jr _ , ] __ i _ —1_ ___, 1 1 i 1 a eilk tillY EXISTING \ °°°°°°°°a°° °°°°e°°°e° °° °° o° °°°o°°o°° 1 ® (TYP) {TYP) v O I ,k, . . _ .___ __ , , . 4. ..ST o� 7 — 7-11,0 E rni / . - n 1 --TT-4 0* 1 cr 12"0-----„J i , ht A or C .� V ,LI. � _ - ° °� _ H-12"0 I FREDMEYER00375 PEM I I — _ - ny STOCK _I] /28"0• I ! TIGARD C) 1111#11 1 123 1 120 I — O 10", � , �.ty 04, . - f12n� --*- i _ - ! PN : 701-00375-06 �� � r ,>`. 11565 SW Pacific Hwy. Rh� � 1 ` � y120 N-12"0 `12 � fr 0 n Tigard, OR, 97223 120 Q a . . \— \-140 1 Ma L t18"0 16"0 -- FURNITURE b �l l I 2�r� I � ► I � � x .� 192 X22" _ 2018 Go-Fast Remodel �TYP}© 1 -- 12° 110 —12"o ' II 1 "12"o 12"0 ECI Job# 73T02 •at1.(--- 4' .L, ©{TYP) O -i 1 O - I ___,,,i,h 111 4 1 I ___ite 0 - Ell ' 0Fred Meyer/ M 1 4 1 I I 1 / i 1 [ B FRED MEYER I STORES, INC _i 1 11 u n ❑ 3800 SE 22nd Ave -'\ -' )---\--,--r ilb _ A Portland, Oregon ff _ - - I 97202 1 Rob Law I f\ DEMOLITION HVAC PLAN - AREA 7 503.797.3519 4, SCALE: 1 /8" = 1 '-0" fredmeyer.com NORTH NEW GENERAL NOTES: O KEY NOTES: These drawings are the property of ArchiTrout Design &Architecture, LLC, and are not to be used A. EQUIPMENT AND DUCTWORK SHOWN DARK AND DASHED TO BE REMOVED. ANY EQUIPMENT 1. EXISTING PACKAGED ROOFTOP TO REMAIN AND BE REUSED. SEE 'M1.1' SHEETS FOR NEW WORK. or reproduced in any manner without prior written permission. AND DUCTWORK SHOWN LIGHTER AND SOLID TO REMAIN. REMOVE AND DISCARD ONLY THE HVAC EQUIPMENT AND DUCTWORK INDICATED. ALL OTHER HVAC EQUIPMENT AND DUCTWORK 2. EXISTING EQUIPMENT TO REMAIN. © 2017 TO REMAIN AND BE REUSED. Pernnit Set 3. REMOVE AND DISCARD EXISTING EQUIPMENT, DUCTWORK AND ALL ASSOCIATED ACCESSORIES. CAP B. ALL EQUIPMENT AND DUCTWORK DISCARDED SHALL BE LEGALLY DISPOSED OF TO AN ALL ROOF PENETRATIONS WATERTIGHT PER ROOF MANUFACTURER'S ROOF WARRANTY AND OFF-SITE LOCATION BY THIS CONTRACTOR. INSTRUCTIONS. 02 . 22 . 2018 C. ALL PATCHING OF ROOF SHALL BE COMPLETED IN ACCORDANCE WITH EXISTING ROOFING 4. REMOVE & DISCARD ONLY ENOUGH DUCTWORK TO RECONNECT TO NEW. SEE 'M1.1' PLANS FOR SYSTEM REQUIREMENTS AND ROOFING MANUFACTURER'S INSTRUCTIONS AND WARRANTIES. NEW WORK. REVISIONS: D. REPLACE ALL EXISTING CONCEALED FLEXIBLE DUCTWORK SECTIONS IN AREAS WITH 5. EXISTING REGISTER, DIFFUSER, OR GRILLE TO REMAIN. SEE 'M1.1' SHEETS FOR AIRFLOW VALUES. REPLACED CEILINGS WITH NEW FLEX DUCT SECTIONS. OLD FLEX DUCT SECTIONS SHALL BE SHEET TITLE REMOVED AND DISCARDED. 6. CAP, PATCH AND SEAL EXISTING DUCTWORK. SMOOTH AND PRIME FOR PAINTING BY PAINT CONTRACTOR. DEMOLITION E. ALL DUCTWORK, INSULATION, EQUIPMENT AND PIPING SIZES ARE TO BE INCHES UNLESS '~' NG NOTED OTHERWISE. 7. REMOVE AND DISCARD EXISTING THERMOSTAT, TEMP SENSOR OR DUCT DETECTOR AND ALL ill mm . ASSOCIATED CONTROL WIRING NOT REUSED. SEE 'M1.1' SHEETS AND 'EM' CONTROL DRAWINGS HVAC PLAN F. THE MECHANICAL CONTRACTOR DUCTWORK, HVAC EQUIPMENT ANDAHANGELL RS , BOOTH DDONCEALEDCARD FANDITNON E ALL NCEALEDD FORR NEW WORK. = -- - AREA 7 THROUGHOUT THE BUILDING. MECHANICAL CONTRACTOR SHALL FIELD VERIFY ALL ABANDONED 8. EXISTING THERMOSTAT OR TEMPERATURE SENSOR TO REMAIN. N A . . : L DUCTWORK AND HVAC EQUIPMENT PRIOR TO BID. 9. EXISTING SUPPLY DIFFUSER, SIDEWALL REGISTER, RETURN OR EXHAUST GRILLE TO BE REMOVED G. MECHANICAL CONTRACTOR TO REMOVE AND DISCARD ALL EXISTING DUCTBOARD DUCTWORK AND DISCARDED. SEE 'M1.1' SHEETS FOR ALL NEW WORK. •, IN THE CONTRACT AREA. DRAWN BY: JJR 10. REMOVE AND DISCARD ALL DUCTWORK AND EQUIPMENT SHOWN DARK AND DASHED (TYP). • i • LI I,- lanai n ,,S4,1--,' y CHECKED BY: CLM 11. EXISTING CO2 SENSOR TO REMAIN. a KEY PLANJ PRELIMINARY NOT FOR CONSTRUCTION PERMIT SET: 02/22/2018 M D 1 • 1 • 7 • 18 19 9. 1 19. 4 200 0 ` ' N 32"x24" rt---- S I--4C--- _41_1 I� I (E)18"0 I r' I i � 3 � I �� ---.1. -r...-1- --- El. V '' \ I'f 1 I 1 Q � 12"0 1 ` x / , r Iy t L� O [-, 1 M 11 11 mil I114 0(TYP) Jri-r4 < i © i III iI iii lk�I __ [[ 1 ,1 .. " I I o Q` 3 - I V N '1]-7 ' ----If 0 Typ) [ E. Es /I MI --H-- A N. I — H 2$"x16" r � 1 . oDo 1I I Iti ,{ I IIIIA o iI I I I I 1 I; " a� 1, 1 I l .� J� 30"x10" I{ —=E EN I■■� i� I 444 .2 1 -_ so . ww . Ionsli—E a lim A IN A 111- ; i NM 6 II1' ( )o (Typo 1 I � ii il 11 ,r_ il �_ F1-4 4 III TYP TYP IIil N ,,. ► 1 r) 1 r 1 I I -_ - .7-i, _. rr 1 _t I I I I I 11111 „„,r1'---- f4r _f441:\ I - I __A: _ , , ., ,,,----„, 1 „ilk ,„ taV �,' 1 0(,,,,,, 1 ♦ -, , . 1 - I t I 12"0 I .__ L ' I 1` - ' \(1 , ,. JET \III . ir 0 , iil EXISTING ` 712ø •1 t` i , )0 I 0 9 / (in' (r. 1 (, EN 1____„. Fl I°'‘f - �� o - 1 I .i i______,r,- I (E}12"0 C_ au RETAIL , 111 ,i— � �.... ■■ � ' :.. - �� � �_ , " � 1 -� 116 I 3 \ / 1 \� 0 w �. i (E)22 I {�i_I O(lYP} — 1 -- I EXISTING r (yP) ❑ � I 1 1 10"0 I N • - ��� 1 ■� p FREDMEYER00375 I� - W ,� 1rt G 1 I 1 1 1 IJ ���0 _ , EXISTING ��� - -No\ J14�2'� � -_ TIGARD - ___E . ��_" II DFC 7 ,a . - �� t(TYP t0 © r�r \ 1I _ 1 • ,I I . , (3(TYp) i EXISTING o '- r t 52 0(TYP) PN : 701-00375--06 (nPO I�jli'i II ,L DCU //a\ ii I ! ao 22'4 I1,►%j.jj \-8"000Ns/ # TYP4 1 � 12"0 oa 12"0. �( ) 1 11565 SW Pacific Hwy. CI / I 1 118 ,.. ti �� 18 -� `� W - T OR, 97223 " - ---- I �u1111 " Tigard,d, I — k - 1 4 I f � I I v ick-Til I I 1 ) 0 _ �` �l '-1 1 "�IIII€ i� _ ! _--1-EXISTING \ //,---- � Z �I / � 1 °D $ 0 TIllt I �, RTS 18"0 �/ BANK I cj 1 I L- 1 O (TYP `� _ O(TYP) �� Ij I I I Go- Fast - \ Illill' - - ,.� O(TYP) I 2018 Go Fast Remodel :40 \8"x8" TG-` z41 J , L-. II I- �190 (TYP)�i — U I�f 1S .. R �ik• !�, (TYP)O .�, i - _ ,2"0 TYP 12"0 -� 24"x6" T + EXISTING ECI Job# 73T02 (TYP) —---------- S7 I I_Ito I --01 I / I 11 1 II 8"0 - r s O(TYP) 2 " m3 / 11 c., i. I lille \ . I I 10 0 `. 1 115 I I I (E "0 I ?VE}18"0 I I?�I I �— _ T:: O(TYP) I - - €� 1 � I I 1 i I1Il,dlulr,,,�. � �� � � TYP) / 1 Fred Meyer PR STING \� I Q �� 0 it ( — T • :Jr 1 o"x4" ST =f„ �, DFC Mm - — I ii ! F)�$" 1 I. I (E)18 ! i�' (010"0 � TENANT t s I 1 '12111II 2 ---rte o EXISTING .!• iI ,Q"o� . J jj .IJ:. DCU 0 12"0 L,._. __ SHOE Ii4 FRED MEYER STOCK OF ) - ; 1._ _ I ( )2 t 1- I I CZ (E)2Q"0 ►=A° I14,$ .. 1 � -T - - - - - STORES, INC I I , I 1 , I € J ;. _. F = , 1 Jultor - - - - -�- - _ I 132 I ii- -- n — 0:3. J <Lr' r_I■ �- ALE . - `I ENTRY BOTTLE 3800 SE 22nd Ave D Q 130 1 r RETURN Portland, Oregon F ❑ .-.1 ❑ � - _: : ( \— - —ted" O O O 97202 �1 S vat, 0 I� a o A i_ , I Rob Law 503.797.3519 NEW GENERAL NOTES: A. EQUIPMENT AND DUCTWORK SHOWN DARK AND DASHED TO BE REMOVED. ANY EQUIPMENT iffik DEMOLITION HVAC PLAN - AREA 9 fredmeyer.com AND DUCTWORK SHOWN LIGHTER AND SOLID TO REMAIN. REMOVE AND DISCARD ONLY THE HVAC EQUIPMENT AND DUCTWORK INDICATED. ALL OTHER HVAC EQUIPMENT AND DUCTWORK ., These drawings are the property of ArchiTrout TO REMAIN AND BE REUSED. NORTH Design &Architecture, LLC, and are not to be used or reproduced in any manner without prior written B. ALL EQUIPMENT AND DUCTWORK DISCARDED SHALL BE LEGALLY DISPOSED OF TO AN permission. OFF-SITE LOCATION BY THIS CONTRACTOR. 0 KEY NOTES: SCALE: 1 /8" = 1 '-0" 0 2017 C. ALL PATCHING OF ROOF SHALL BE COMPLETED IN ACCORDANCE WITH EXISTING ROOFING oft SYSTEM REQUIREMENTS AND ROOFING MANUFACTURER'S INSTRUCTIONS AND WARRANTIES. 1. EXISTING PACKAGED ROOFTOP TO REMAIN AND BE REUSED. SEE 'M1.1' SHEETS FOR NEW WORK. Lirai IN AREASWITH U N Permit Set D. REPLACE ALL EXISTING CONCEALED FLEXIBLE DUCTWORK SECTIONS 2. EXISTING EQUIPMENT TO REMAIN. REPLACED CEILINGS WITH NEW FLEX DUCT SECTIONS. OLD FLEX DUCT SECTIONS SHALL BE - REMOVED AND DISCARDED. 3. REMOVE AND DISCARD EXISTING EQUIPMENT, DUCTWORK AND ALL ASSOCIATED ACCESSORIES. CAP 02 . 22 . 2018 ALL ROOF PENETRATIONS WATERTIGHT PER ROOF MANUFACTURER'S ROOF WARRANTY AND ., E. ALL DUCTWORK, INSULATION, EQUIPMENT AND PIPING SIZES ARE TO BE INCHES UNLESS INSTRUCTIONS. NOTED OTHERWISE. L, l REVISIONS. In F. THE MECHANICAL CONTRACTOR SHALL REMOVE AND DISCARD OFF-SITE ALL ABANDONED 4. REMOVE & DISCARD ONLY ENOUGH DUCTWORK TO RECONNECT TO NEW. SEE 'M1.1' PLANS FOR ,, ®® NEW WORK. DUCTWORK, HVAC EQUIPMENT AND HANGERS, BOTH CONCEALED AND NON-CONCEALED, ' m� THROUGHOUT THE BUILDING. MECHANICAL CONTRACTOR SHALL FIELD VERIFY ALL ABANDONED .... "- "' _ ,,_ ' !1l■,.--- m SHEET TITLE: DUCTWORK AND HVAC EQUIPMENT PRIOR TO BID. 5. EXISTING REGISTER, DIFFUSER, OR GRILLE TO REMAIN. SEE M1.1 SHEETS FOR AIRFLOW VALUES. 6. CAP, PATCH AND SEAL EXISTING DUCTWORK. SMOOTH AND PRIME FOR PAINTING BY PAINT KEY PLAN DEMOLITION G. MECHANICAL CONTRACTOR TO REMOVE AND DISCARD ALL EXISTING DUCTBOARD DUCTWORK CONTRACTOR. IN THE CONTRACT AREA. HVAC PLAN 7. REMOVE AND DISCARD EXISTING THERMOSTAT, TEMP SENSOR OR DUCT DETECTOR AND AL�� E LI M I NARY NOT FOR CONSTRUCTION PERMIT SET:02/22/2018 ASSOCIATED CONTROL WIRING NOT REUSED. SEE 'M1.1' SHEETS AND 'EM' CONTROL DRAW MGS� AREA 9 FOR NEW WORK. 8. EXISTING THERMOSTAT OR TEMPERATURE SENSOR TO REMAIN. DRAWN BY: JJR 9. EXISTING SUPPLY DIFFUSER, SIDEWALL REGISTER, RETURN OR EXHAUST GRILLE TO BE REMOVED AND DISCARDED. SEE 'M1.1' SHEETS FOR ALL NEW WORK. CHECKED BY: CLM 10. REMOVE AND DISCARD ALL DUCTWORK AND EQUIPMENT SHOWN DARK AND DASHED (TYP). _ 11. EXISTING CO2 SENSOR TO REMAIN. MD1 . 1 . 9 20 21 22 NEW GENERAL NOTES: A. NEW EQUIPMENT AND DUCTWORK SHOWN DARK AND SOLID. ANY EQUIPMENT AND DUCTWORK (-1 -Anniume -_ -—__ . _.__. - - -- SHOWN LIGHTER AND SOLID TO REMAIN -Fp °Q g '" .4. F, B. ALL ROOF PENETRATIONS SHALL BE COMPLETED IN ACCORDANCE WITH ROOFING SYSTEM a Ma � I .ILII1110:, ;^e i� t tri K - - REQUIREMENTS AND ROOF MANUFACTURER'S INSTRUCTIONS. COORDINATE ALL WORK WITH a , . I r7 ROOFING CONTRACTOR. ▪ o N �F0 0CFMN C. CONTRACTOR SHALL VERIFY EXACT HEIGHTS OF ALL CEILINGS & DECOR ITEMS PRIOR TO • o O 200 CFM 20 200 CFM @ 240 CFM 240 CFM t M START OF WORK. SEE ARCHITECTURAL SHEETS FOR DETAILS AND CONSTRUCTION. wo .n " 10"� COORDINATE EXACT DUCTWORK INSTALLATION WITH CEILING & DECOR AND STRUCTURE, AS a� \ \ / 100•-\ \ I /tip _ _ \ / \ I / \ I / \ I / REQUIRED. o Q � } .■ I I 1 : ►—,. 1 16"O III 14ro [ ill 17"0 i II I I i 04 N t._ Ilit IIN - 1 - . r 3 . .�. - D. SEE ELECTRICAL LIGHTING SHEETS FOR EXACT LOCATION OF ALL LIGHT FIXTURES. C 0 M I — COORDINATE EXACT DIFFUSER AND GRILLE LOCATIONS WITH LIGHTING FIXTURES, AS co OFFSET DROP TIGHT I REQUIRED. INSTALL AND MAINTAIN A MINIMUM OF 36" FROM LIGHT FIXTURE IN ALL OPEN a o _ KEYPLAN TO WALL AREAS WITHOUT DROP CEILINGS. ' pil 22"0ACR 18 E. INSTALL ALL DUCTWORK AS HIGH AS POSSIBLE WHILE COORDINATING WITH ALL OTHER W - Y NOT FOR CONSTRUCTION PERMIT SET: 02/22/2018 TRADES. OFFSET AND TRANSITION DUCTWORK BETWEEN AND BENEATH STRUCTURAL MEMBERS, WHERE REQUIRED. DROP BRANCH DUCTS DOWN TO DIFFUSERS AND GRILLES. , F. ALL DUCTWORK SHALL MEET SMACNA'S "HVAC DUCT CONSTRUCTION STANDARDS - METAL NIEW\\NFI\. :A\HC PLAN - ALE MEZZANINE AND FLEXIBLE", CURRENT EDITION. DUCT GAUGES, REINFORCEMENTS, METHODS OF I\ NOTE: CONNECTION, TRANSITIONS AND CONSTRUCTION WILL BE FIELD-VERIFIED, MEASURED AND I FIELD VERIFY EXISTING HEIGHTS OF EXISTING INSPECTED FOR COMPLIANCE. DUCTWORK NOT MEETING SMACNA'S STANDARDS WILL BE ,,k4akk GI 1 SCALE: 118'x= '� DUCTWORK SHOWN TO REMAIN ON SALES REMOVED AND REPLACED AT CONTRACTOR'S EXPENSE. SEE THE SPECIFICATIONS FOR THE 18 19 19. 1 9. ', 20 21 FLOOR PRIOR TO BID. RAISE DUCTWORK AS 22 REQUIRED PRESSURE CLASSIFICATION FOR ALL DUCTWORK. CONTRACTOR SHALL VERIFY ALL P NORTH REQUIRED TO BE SAME ELEVATION AS NEW REQUIREMENTS PRIOR TO SUBMITTALS OR DUCT FABRICATION AND GIVE WRITTEN LIGHTS. DOCUMENTATION OF COMPLIANCE IN ORIGINAL PRODUCT SUBMITTALS. ` G. ALL DUCTWORK IN EXPOSED SALES AREAS SHALL BE SHEET METAL ONLY, NO FLEX DUCT ALLOWED. FINAL CONNECTIONS TO DIFFUSERS, GRILLES AND REGISTERS SHALL BE SHEET �� METAL DUCT ONLY. SUPPORT DUCTWORK PER SMACNA AND CODE. FURNISH WITH PAINT-LOC FINISH OR PRIME FOR PAINTING. t H. ALL DIMENSIONS ARE LISTED IN INCHES UNLESS NOTED OTHERWISE. ALL DUCTWORK DIMENSIONS ARE INSIDE CLEAR. I. HVAC CONTRACTOR SHALL FIELD-COORDINATE ALL CONDITIONS, UNIT LOCATIONS, FRED I\/1 EYE R OBSTRUCTIONS AND DUCTWORK INSTALLATION PRIOR TO DUCT FABRICATION. TRANSITION AND 00375 OFFSET DUCTWORK, AS REQUIRED, TO MAKE FIT IN CEILING SPACES AND FIELD CONDITIONS. DUCTWORK FABRICATED BY THE HVAC CONTRACTOR PRIOR TO FIELD COORDINATION AND ' ' o �� CONFLICT RESOLUTION SHALL BE AT THE RESPONSIBILITY AND COST OF THE HVAC TI G A R D 1 CONTRACTOR. OWNER SHALL NOT BE RESPONSIBLE FOR SHOP-FABRICATED DUCTWORK 0 ® \ �� SIZED DIRECTLY FROM THE HVAC DRAWINGS. \ J. DO NOT CUT, DRILL HOLES OR REMOVE ANY PORTION OF STRUCTURAL MEMBERS, BEAMS P N : 701-00375_06 �,. OR PURLINS. ROUTE ALL DUCTWORK, PIPING AND CONDUIT AROUND AND THROUGH ° STRUCTURAL MEMBERS AS REQUIRED. SEE STRUCTURAL DETAILS AND DRAWINGS FOR EXACT METHOD OF ATTACHING HANGERS TO BEAMS AND STRUCTURAL MEMBERS. 1.1565 S W Pacific H Wy. �� �� �, K. DO NOT ATTACH SCREWS, NAILS, HANGERS OR FASTENERS OF ANY TYPE TO ROOF PECK. Tigard, O R, 97223 Li ° ° /► ° R SUPPORT ALL MECHANICAL EQUIPMENT FROM STRUCTURE AND CONTRACTOR-INSTALLED mac __._./\° _ Mr ! _ - KICKERS ONLY. PROVIDE AND INSTALL INTERMEDIATE KICKERS BETWEEN PURLINS AS 2018 Go-Fast Remodel O n � ..i � ° _ L � - \ REQUIRED TO HANG EQUIPMENT AND SHEET METAL DUCTWORK. L RECEIVING 11-111° 'I� HII 24"x12"�y �. L. ALL TEMPERATURE CONTROLS, EMS CONTROLS AND SMOKE DETECTOR SHUT-DOWN WORK ECI Job# 73T02 171 ® '�' DOWN FROM 17 SHALL BE COMPLETED BY EMS CONTROLS CONTRACTOR, UNLESS NOTED OTHERWISE. SEE MEZZANINE1111111111111 'EM' SHEETS FOR ALL ASSOCIATED WORK. �� Meyer ALE 200 CFMO M. MECHANICAL CONTRACTOR SHALL FIELD-ADJUST ALL DIFFUSERS, REGISTERS AND DRUM O 200 CFM O 200 CFM _- -----"- 200 CFM O 200 CFM STOCK 0200 CFM LOUVERS DISCHARGE AIRFLOW AWAY FROM ALL OPEN REFRIGERATED CASES, SWAYING 10"0 SIGNAGE, CHECK STAND/PREP WEIGHT SCALES AND OTHER NOTICEABLE CONFLICTING \ I / \ I,/ \ I / \ I / r-_. \ I / 10" \ / LOCATIONS AT THE COMPLETION OF CONSTRUCTION. I I i i i� 18 16"0 III 14-0 I I I 17'"� I I L I FRED EYE411 I I (------ 0 I I _ - • 1 1.. N. MECHANICAL CONTRACTOR SHALL PROVIDE AND INSTALL PERMANENT ENGRAVED M R LI, LI PLASTIC-LAMINATE SIGNS WITH MINIMUM 1"-TALL LETTERING AT ALL ROOFTOP UNITS, - - 1- -rt ; , "� I - l I j EXHAUST FANSAAND (HVAC EQUIPMENT LOCATIONS THROUGHOUT ENTIRE BUILDING AND - I _ STORES, INC 1_ ROOFTOP. MOUNT PERMANENTLY IN AN APPROPRIATE AND EFFECTIVE LOCATION, WITH UNIT / DESIGNATION AND AREA SERVED SHOWN, PRIOR TO FINAL PUNCH DATE. SEE EMS CONTROL DRAWINGS FOR LABELING OF ALL REMOTE SENSORS, THERMOSTATS AND CONTROL DEVICES. IL,,,__________1 22"0 UP TO " " -, I 0. SUPPLY AND RETURN DUCTWORK FROM ROOFTOP UNITS TO BE INTERNALLY INSULATED A 3 800 S E 2 2nd Ave PRODUCE DAIRY MEZZANINE _ 24"x14" DL 30"x10" DL COOLER 700 CFM MINIMUM OF TEN FEET FOR SOUND ATTENUATION. ALL SUPPLY AND RETURN DUCTWORK IN Portland, Oregon PREP. 1,120 CFM SPACES ABOVE CEILINGS SHALL BE INSULATED PER NEW DUCT INSULATION SCHEDULE ON _ SHEET M6.1.1. 97202 rP. ALL BRANCH DUCTS OFF MAIN DUCT TO BE INSTALLED WITH 45' TIME-AND-A-HALF FITTING, _ O n- (2-v--- I BELL-MOUTH FITTING, OR SPIN-IN ONLY. NO STRAIGHT TAPS ALLOWED. - ice, I ! ge a Ihi� IIMiiRob Law /� - Q. FLEXIBLE DUCT RUNS SHALL BE NO LONGER THAN 6'-0". ( R. MECHANICAL CONTRACTOR SHALL CLEAN, SCRUB AND PRIME FOR FINAL PAINTING BY 03,797.3519 j' PAINTING CONTRACTOR ALL VISIBLE DUCTWORK, WHETHER REMAINING, RELOCATED OR NEW. J ( ��., _ FIELD-VERIFY ALL DUCTS, LOCATIONS AND REQUIREMENTS PRIOR TO BID. f re d m eye r.Co m J_)J-J)_)_)_JJJ_J-r N S. ALL DUCTWORK SERVING SPACES UNDER THE MEZZANINE MUST BE COORDINATED WITH STRUCTURE. BRANCH DUCTWORK TO RUN THROUGH STRUCTURAL JOISTS. 20"x10" DL OKEYNOTES: e690 CFM j (rYP OF 4) �' 30 x10 _ 1. EXISTING ROOFTOP UNIT OR AIR HANDLING UNIT TO REMAIN. IF AIRFLOW VALUES ARE LISTED ON —� I PLAN, BALANCE CONTRACTOR SHALL BALANCE EXISTING ROOFTOP UNIT OR AIR HANDLING UNIT (�P)Q TO AIRFLOW VALUES LISTED. REPORT ANY DEFICIENCIES TO GENERAL CONTRACTOR AND KROGER " --- -- 20"� NW PROJECT MANAGER IMMEDIATELY. { DL I • .a-- / I \ O ril 2. EXISTING EQUIPMENT TO REMAIN. 1 I 1Permit IV Set,..__ _ _ ____, ,_. .MP-O-F-1-3) 3. INSTALL BRANCH DUCT OFF MAIN DUCT WITH 45' TIME-AND-A-HALF FITTING OR SPIN-IN ONLY. .I. ; NO STRAIGHT TAPS ALLOWED. 02 . 22 . 2018 0 E. `26"0 I i moi/ 4. NEW TEMPERATURE SENSOR FURNISHED AND INSTALLED BY CONTROLS CONTRACTOR. SEE 'EM' • -18 ! CONTROL DRAWINGS FOR ALL CONTROLS WORK. TEMPERATURE SENSOR SHALL NOT BE LOCATED i11I WHERE THE THROW OF A SUPPLY DIFFUSER WILL INTERFERE WITH THE SENSOR. REVISIONS: 5. VAV DIFFUSER, TYPE VAVD. SEE GRILLES, REGISTERS AND DIFFUSERS SCHEDULE ON SHEET M6.2 -tit— ----J--- EXISTING - —f -— _, FOR MORE INFORMATION. SET COOLING SETPOINT TO 73'F AND HEATING SETPOINT TO 68'F. SHEET TITLE: t I 1 II II 1 I 1 1 11 I`II10 _ all to6. MOUNT RELATIVE HUMIDITY SENSOR AT 58" A.F.F. NEW HVAC 7. RUN ALL DUCTWORK LEVEL AT SAME ELEVATION AS EXISTING OR RAISED DUCTWORK. PLAN _ AREA 3 " NJ E\/\f H VAC PLAN - AREA 3 8. EXISTING THERMOSTAT OR TEMPERATURE SENSOR TO REMAIN. 9. CONNECT NEW DUCTWORK TO EXISTING DUCTWORK. VERIFY EXISTING DUCT SIZES AND -/ ELEVATIONS. TRANSITION WHERE REQUIRED. DRAWN BY: JJR NORTH 10. LEAVE DUCT OPEN ON THE END OR TOP AS SHOWN AND COVER WITH 1/2"x1/2" WELDED WIRE CHECKED BY: CLM MESH WITH REINFORCED STEEL FRAME. These drawings are the property of ArchiTrout - Design &Architecture, LLC, and are not to be used 11. EXISTING CO2 SENSOR TO REMAIN. FIELD VERIFY EXISTING LOCATION. or reproduced in any manner without prior written permission. 12. STAND-ALONE DIGITAL, NIGHT-SETBACK CAPABLE, PROGRAMMABLE THERMOSTAT FURNISHED BY © 2017 CONTROLS CONTRACTOR. SEE 'EM' CONTROL DRAWINGS. M 1 • 11 • 3 SCALE: 1/8" = V-0" 13. NEW RELATIVE HUMIDITY SENSOR FURNISHED BY CONTROLS CONTRACTOR. SEE 'EM' CONTROLS DRAWINGS. 14. BALANCE EXISTING SUPPLY REGISTER, RETURN OR EXHAUST GRILLE TO AIRFLOW INDICATED. ALIGN ADJUSTABLE BLADES FOR EVEN DIFFUSION. GI 18 19 19. 1 19. X20 21 0 . (., _ 1 1- 03 l �,, I t- - , , . , TEXISTING t......1:1----ji......._ - I , i a� A8 i ��I��Illlllliiluuu� CO:s. — c� " " +4 X 52x24 �, 'o 1�����rn, q,�,u,,,,, o 0 I rlr II � v I . �IIIIIIIIIIIIIF�I 48"x24" RG c oNo Q? - , I 2,500 CFM U �. \ (TYP OF 4) F __J NOTE: 0 M PRLIM1NA Y NOT FOR C9NSTRUCTION PERMIT SET. 22 201 • FIELD VERIFY EXISTING HEIGHTS OF EXISTING I 1 02/22/201i- +r ' J — DUCTWORK SHOWN TO REMAIN ON SALES a� o FLOOR PRIOR TO BID. RAISE DUCTWORK AS 1 00 REQUIRED TO BE SAME ELEVATION AS NEW a °' ;; 4- In // I lIl LIGHTS. W - 1- ....., Ill II / / 1. _ == . . . . . .. . _ _ _ , . _ , . . . my , _ . 1 =MN It are ._,• link : A .2 •J I i p 1 II , MINE MEM , a ft MEM MIMI 11111 "''... �♦ 3:3: -311,-_-.1. N /` I W — IE KEY PLAN 1 , 30"x10" DL _ FRED MEYER00375 1,110 CFM ___ ___ I���f I(TYP OF 5) "�/(E)3OTIGAR D AC-18,25,3• ,C=1-8 7 CO24§1, --7------------ 02 Q� . (TYP) 3 I " �- _ - (TYP)© 20 P N : 701-00375-06 \ I / . / Q / / / Pacific / , �� , ,t 11565 SW Hwy. ' IISLE 0 1 1 ) y l -� - t Tigard, OR, 97223 / — — — — - a 2018 Go-Fast Remodel rn % v ECl Job# 73T02 CI / Fred !Weyer I //// CL I 1 L._ _____ . / .__I] FRED MEYER - - . , ,i. . - ,-� )- - --- STORES, INC i , ---- r _.>-1 , I I , i }34" ; _ , 3800 SE 22nd Ave •—, N _ /28-,16- Portland, Oregon _ / / - 97202 i - - // \ ! I 48"x24" iii _ Rob Law LO N 2,500-CFM - I• - ____r_ ------ -- � Li.i Lo JP /78"x16" (TYP OF 3}— 503.797.3519 r ' II I I fremeyer.com1 © 1 I o ,�� � - )22"� IH I _ - I — EXISTING L----'--J — �i`=1 $). EXISTING . _Z--,—' {(1 P f I AC 30"x,10" DL _ 1_ )© - I - ..�1 - - -. i11 N lk .‘s. o I ' 17 O 1;00 ��� 20"x10" DL : �TYP OF 3) _— ``� 690 CFM _ 22"0 RA "i"x4$" These drawings are the property of ArchiTrout (TYP 1 IL I�1 OPENING IN TOP. TYP OF 6 _ i ". __---I °O BALANCE TO 3,000 CFM Design &Architecture, LIC, and are not to be used 32"x24 w or reproduced in any manner without prior written �28"x16" — permission. © 2017 ` ��.� I � + rr-- — (F) 47,4 ,11, 0 KEY NOTES: di\ NEW HVAC PLAN - AREA 6 K. DO NOT ATTACH SCREWS, NAILS, HANGERS OR FASTENERS OF ANY TYPE TO ROOF DECK. Permit Set 1. EXISTING ROOFTOP UNIT OR AIR HANDLING UNIT TO REMAIN. IF AIRFLOW VALUES ARE LISTED ON SUPPORT ALL MECHANICAL EQUIPMENT FROM STRUCTURE AND CONTRACTOR-INSTALLED KICKERS ONLY. PROVIDE AND INSTALL INTERMEDIATE KICKERS BETWEEN PURLINS AS PLAN, BALANCE CONTRACTOR SHALL BALANCE EXISTING ROOFTOP UNIT OR AIR HANDLING UNIT TO AIRFLOW VALUES LISTED. REPORT ANY DEFICIENCIES TO GENERAL CONTRACTOR AND KROGER ', F. ALL DUCTWORK SHALL MEET SMACNA'S "HVAC DUCT CONSTRUCTION STANDARDS - METAL REQUIRED TO HANG EQUIPMENT AND SHEET METAL DUCTWORK. 02 . 22 . 2018 NW PROJECT MANAGER IMMEDIATELY. NORTHSCALE: 1/8" = 1 '� FLEXIBLE , CURRENT EDITION. DUCT GAUGES, REINFORCEMENTS, METHODS OFNECTION, TRANSITIONS AND CONSTRUCTION WILL BE FIELD-VERIFIED, MEASURED AND L. ALL TEMPERATURE CONTROLS, EMS CONTROLS AND SMOKE DEFECTOR SHUT-DOWN WORK N 2. EXISTING EQUIPMENT TO REMAIN. 13. NEW RELATIVE HUMIDITY SENSOR FURNISHED BY CONTROLS CONTRACTOR. SEE 'EM' CONTROLS INSPECTED FOR COMPLIANCE. DUCTWORK NOT MEETING SMACNA'S STANDARDS WILL BE SHALL BE COMPLETED BY EMS CONTROLS CONTRACTOR, UNLESS NOTED OTHERWISE. SEE p C� /I C I O N c • DRAWINGS. REMOVED AND REPLACED AT CONTRACTOR'S EXPENSE. SEE THE SPECIFICATIONS FOR THE 'EM' SHEETS FOR ALL ASSOCIATED WORK. t1C V .7 J 3. INSTALL BRANCH DUCT OFF MAIN DUCT WITH 45' TIME-AND-A-HALF FITTING OR SPIN-IN ONLY. REQUIRED PRESSURE CLASSIFICATION FOR ALL DUCTWORK. CONTRACTOR SHALL VERIFY ALL NO STRAIGHT TAPS ALLOWED. 14. BALANCE EXISTING SUPPLY REGISTER, RETURN OR EXHAUST GRILLE TO AIRFLOW INDICATED. REQUIREMENTS PRIOR TO SUBMITTALS OR DUCT FABRICATION AND GIVE WRITTEN M. MECHANICAL CONTRACTOR SHALL FIELD-ADJUST ALL DIFFUSERS, REGISTERS AND DRUM SHEET TITLE: ALIGN ADJUSTABLE BLADES FOR EVEN DIFFUSION. DOCUMENTATION OF COMPLIANCE IN ORIGINAL PRODUCT SUBMITTALS. LOUVERS DISCHARGE AIRFLOW AWAY FROM ALL OPEN REFRIGERATED CASES, SWAYING 4. NEW TEMPERATURE SENSOR FURNISHED AND INSTALLED BY CONTROLS CONTRACTOR. SEE 'EM' G. ALL DUCTWORK IN EXPOSED SALES AREAS SHALL BE SHEET METAL ONLY, NO FLEX DUCT SIGNAGE, CHECK STAND/PREP WEIGHT SCALES AND OTHER NOTICEABLE CONFLICTING NEW HVAC CONTROL DRAWINGS FOR ALL CONTROLS WORK. TEMPERATURE SENSOR SHALL NOT BE LOCATED NEW GENERAL NOTES. ALLOWED. FINAL CONNECTIONS TO DIFFUSERS, GRILLES AND REGISTERS SHALL BE SHEET LOCATIONS AT THE COMPLETION OF CONSTRUCTION. WHERE THE THROW OF A SUPPLY DIFFUSER WILL INTERFERE WITH THE SENSOR. ' METAL DUCT ONLY. SUPPORT DUCTWORK PER SMACNA AND CODE. FURNISH WITH PAINT-LOC PLAN - AREA fi A. NEW EQUIPMENT AND DUCTWORK SHOWN DARK AND SOLID- ANY EQUIPMENT AND DUCTWORK FINISH OR PRIME FOR PAINTING. N. MECHANICAL CONTRACTOR SHALL PROVIDE AND INSTALL PERMANENT ENGRAVED 5. VAV DIFFUSER, TYPE VAVD. SEE GRILLES, REGISTERS AND DIFFUSERS SCHEDULE ON SHEET M6.2 SHOWN LIGHTER AND SOLID TO REMAIN. PLASTIC-LAMINATE SIGNS WITH MINIMUM 1"-TALL LETTERING AT ALL ROOFTOP UNITS, FOR MORE INFORMATION. SET COOLING SETPOINT TO 73'F AND HEATING SETPOINT TO 68'F. H. ALL DIMENSIONS ARE LISTED IN INCHES UNLESS NOTED OTHERWISE. ALL DUCTWORK EXHAUST FANS AND HVAC EQUIPMENT LOCATIONS THROUGHOUT ENTIRE BUILDING AND B. ALL ROOF PENETRATIONS SHALL BE COMPLETED IN ACCORDANCE WITH ROOFING SYSTEM DIMENSIONS ARE INSIDE CLEAR. ROOFTOP. MOUNT PERMANENTLY IN AN APPROPRIATE AND EFFECTIVE LOCATION, WITH UNIT DRAWN BY: JJR 6. MOUNT RELATIVE HUMIDITY SENSOR AT 58" A.F.F. REQUIREMENTS AND ROOF MANUFACTURER'S INSTRUCTIONS. COORDINATE ALL WORK WITH DESIGNATION AND AREA SERVED SHOWN, PRIOR TO FINAL PUNCH DATE. SEE EMS CONTROL ROOFING CONTRACTOR. I. HVAC CONTRACTOR SHALL FIELD-COORDINATE ALL CONDITIONS, UNIT LOCATIONS, DRAWINGS FOR LABELING OF ALL REMOTE SENSORS, THERMOSTATS AND CONTROL DEVICES. CHECKED BY: CLM 7. RUN ALL DUCTWORK LEVEL AT SAME ELEVATION AS EXISTING OR RAISED DUCTWORK. OBSTRUCTIONS AND DUCTWORK INSTALLATION PRIOR TO DUCT FABRICATION. TRANSITION AND C. CONTRACTOR SHALL VERIFY EXACT HEIGHTS OF ALL CEILINGS & DECOR ITEMS PRIOR TO OFFSET DUCTWORK, AS REQUIRED, TO MAKE FIT IN CEILING SPACES AND FIELD CONDITIONS. O. SUPPLY AND RETURN DUCTWORK FROM ROOFTOP UNITS TO BE INTERNALLY INSULATED A B. EXISTING THERMOSTAT OR TEMPERATURE SENSOR TO REMAIN. START OF WORK. SEE ARCHITECTURAL SHEETS FOR DETAILS AND CONSTRUCTION. DUCTWORK FABRICATED BY THE HVAC CONTRACTOR PRIOR TO FIELD COORDINATION AND MINIMUM OF TEN FEET FOR SOUND ATTENUATION. ALL SUPPLY AND RETURN DUCTWORK IN COORDINATE EXACT DUCTWORK INSTALLATION WITH CEILING & DECOR AND STRUCTURE, AS CONFLICT RESOLUTION SHALL BE AT THE RESPONSIBILITY AND COST OF THE HVAC SPACES ABOVE CEILINGS SHALL BE INSULATED PER NEW DUCT INSULATION SCHEDULE ON 9. CONNECT NEW DUCTWORK TO EXISTING DUCTWORK. VERIFY EXISTING DUCT SIZES AND REQUIRED. CONTRACTOR. OWNER SHALL NOT BE RESPONSIBLE FOR SHOP-FABRICATED DUCTWORK SHEET M6.1.1. ELEVATIONS. TRANSITION WHERE REQUIRED. SIZED DIRECTLY FROM THE HVAC DRAWINGS. P. ALL BRANCH DUCTS OFF MAIN DUCT TO BE INSTALLED WITH 45' TIME-AND-A-HALF FITTING, M il • 1 • 6 D. SEE ELECTRICAL LIGHTING SHEETS FOR EXACT LOCATION OF ALL LIGHT FIXTURES. BELL-MOUTH FITTING, OR SPIN-IN ONLY. NO STRAIGHT TAPS ALLOWED. 10- LEAVE DUCT OPEN ON THE END OR TOP AS SHOWN AND COVER WITH 1/2"x1/2" WELDED WIRE COORDINATE EXACT DIFFUSER AND GRILLE LOCATIONS WITH LIGHTING FIXTURES, AS J. DO NOT CUT, DRILL HOLES OR REMOVE ANY PORTION OF STRUCTURAL MEMBERS, BEAMS MESH WITH REINFORCED STEEL FRAME. REQUIRED. INSTALL AND MAINTAIN A MINIMUM OF 36" FROM LIGHT FIXTURE IN ALL OPEN OR PURLINS. ROUTE ALL DUCTWORK, PIPING AND CONDUIT AROUND AND THROUGH Q. FLEXIBLE DUCT RUNS SHALL BE NO LONGER THAN 6'-0". AREAS WITHOUT DROP CEILINGS. STRUCTURAL MEMBERS AS REQUIRED. SEE STRUCTURAL DETAILS AND DRAWINGS FOR EXACT 11. EXISTING CO2 SENSOR TO REMAIN. FIELD VERIFY EXISTING LOCATION. METHOD OF ATTACHING HANGERS TO BEAMS AND STRUCTURAL MEMBERS. R. MECHANICAL CONTRACTOR SHALL CLEAN, SCRUB AND PRIME FOR FINAL PAINTING BY E. INSTALL ALL DUCTWORK AS HIGH AS POSSIBLE WHILE COORDINATING WITH ALL OTHER PAINTING CONTRACTOR ALL VISIBLE DUCTWORK, WHETHER REMAINING, RELOCATED OR NEW. 12. STAND-ALONE DIGITAL, NIGHT-SETBACK CAPABLE, PROGRAMMABLE THERMOSTAT FURNISHED BY TRADES. OFFSET AND TRANSITION DUCTWORK BETWEEN AND BENEATH STRUCTURAL FIELD-VERIFY ALL DUCTS, LOCATIONS AND REQUIREMENTS PRIOR TO BID. CONTROLS CONTRACTOR. SEE 'EM' CONTROL DRAWINGS. MEMBERS, WHERE REQUIRED. DROP BRANCH DUCTS DOWN TO DIFFUSERS AND GRILLES. S. ALL DUCTWORK SERVING SPACES UNDER THE MEZZANINE MUST BE COORDINATED WITH STRUCTURE. BRANCH DUCTWORK TO RUN THROUGH STRUCTURAL JOISTS. 0 0 4 NEW GENERAL NOTES: �� A. NEW EQUIPMENT AND DUCTWORK SHOWN DARK AND SOLID. ANY EQUIPMENT AND DUCTWORK SHOWN LIGHTER AND SOLID TO REMAIN. N I Till — \ B. ALL ROOF PENETRATIONS SHALL BE COMPLETED IN ACCORDANCE WITH ROOFING SYSTEM J _ REQUIREMENTS AND ROOF MANUFACTURER'S INSTRUCTIONS. COORDINATE ALL WORK WITH Iv MI A ______ i U ROOFING CONTRACTOR. ,� GO U o \ C. CONTRACTOR SHALL VERIFY EXACT HEIGHTS OF ALL CEILINGS & DECOR ITEMS PRIOR TO ; c� START OF WORK. SEE ARCHITECTURAL SHEETS FOR DETAILS AND CONSTRUCTION. ` COORDINATE EXACT DUCTWORK INSTALLATION WITH CEILING & DECOR AND STRUCTURE, AS vs cl o �► n I{\- REQUIRED. � \ _ Cc) 7 "-- / ; O 1� /IIt� di 1_I I D. SEE ELECTRICAL LIGHTING SHEETS FOR EXACT LOCATION OF ALL LIGHT FIXTURES. • ° o COORDINATE EXACT DIFFUSER AND GRILLE LOCATIONS WITH LIGHTING FIXTURES, AS an ``�' rn fil .� REQUIRED. INSTALL AND MAINTAIN A MINIMUM OF 36" FROM LIGHT FIXTURE IN ALL OPEN (111; t 1 oc AREAS WITHOUT DROP CEILINGS. o \\ E. INSTALL ALL DUCTWORK AS HIGH A5 POSSIBLE WHILE COORDINATING WITH ALL OTHER \ "411 11170-11 _ TRADES. OFFSET AND TRANSITION DUCTWORK BETWEEN AND BENEATH STRUCTURAL W c \ i -- =� MEMBERS, WHERE REQUIRED. DROP BRANCH DUCTS DOWN TO DIFFUSERS AND GRILLES. Al F. ALL DUCTWORK SHALL MEET SMACNA'S "HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE", CURRENT EDITION. DUCT GAUGES, REINFORCEMENTS, METHODS OF CONNECTION, TRANSITIONS AND CONSTRUCTION WILL BE FIELD-VERIFIED, MEASURED AND INSPECTED FOR COMPLIANCE. DUCTWORK NOT MEETING SMACNA'S STANDARDS WILL BE 4q1 -411. itt. ,..1, 1 I14 \ REMOVED AND REPLACED AT CONTRACTOR'S EXPENSE. SEE THE SPECIFICATIONS FOR THE �' ' I REQUIRED PRESSURE CLASSIFICATION FOR ALL DUCTWORK. CONTRACTOR SHALL VERIFY ALL Q \ — — ® \ REQUIREMENTS PRIOR TO SUBMITTALS OR DUCT FABRICATION AND GIVE WRITTEN — — — — DOCUMENTATION OF COMPLIANCE IN ORIGINAL PRODUCT SUBMITTALS. ‘‘41?' g — -- - - — — ® — G. ALL DUCTWORK IN EXPOSED SALES AREAS SHALL BE SHEET METAL ONLY, NO FLEX DUCT �` - - - - � — �- r ALLOWED. FINAL CONNECTIONS TO DIFFUSERS, GRILLES AND REGISTERS SHALL BE SHEET �� — _ ® � L \,\ METAL DUCT ONLY. SUPPORT DUCTWORK PER SMACNA AND CODE. FURNISH WITH PAINT-LOC ® — — — —F—I FINISH OR PRIME FOR PAINTING. ® ® , E3(IST�N d --- I o \1 1 I 1 € 1 H. ALL DIMENSIONS ARE LISTED IN INCHES UNLESS NOTED OTHERWISE. ALL DUCTWORK I ® — - v DIMENSIONS ARE INSIDE CLEAR. \ ! \ 0 5,204 CF-IA 1 505 CFM: 71 — — — ¶05 CF \ --,414.. \ 1 1 h �� \ -- „ �r r ' .rigI. HVAC CONTRACTOR SHALL FIELD-COORDINATE ALL CONDITIONS, UNIT LOCATIONS 16_ 1-1 ;.• C -7; EP ►� /-12"0 18"x10" DL OBSTRUCTIONS AND DUCTWORK INSTALLATION PRIOR TO DUCT FABRICATION. TRANSITION AND FRED N/I EY E R 003 7 5 \� \ , N T 12"�-i �� — \ �� 500 CFM I _ OFFSET DUCTWORK, AS REQUIRED, TO MAKE FIT IN CEILING SPACES AND FIELD CONDITIONS. \ 1LL _x0 — I1 11 � I •IYP OF } DUCTWORK FABRICATED BY THE HVAC CONTRACTOR PRIOR TO FIELD COORDINATION AND ,;_ CONFLICT RESOLUTION SHALL BE AT THE RESPONSIBILITY AND COST OF THE HVAC TIGARD \ .--0 - 1\ I'_ -' D CONTRACTOR. OWNER SHALL NOT BE RESPONSIBLE FOR SHOP-FABRICATED DUCTWORK 1� ,...17.,,a__., ' �i-i -. - SIZEDDIRECTLY FROM THE HVAC DRAWINGS. '\' \ D D EC a GS \� " - \\� I __ Asa '' dtp - J. DO NOT CUT, DRILL HOLES OR REMOVE ANY PORTION OF STRUCTURAL MEMBERS, BEAMS P N : 701-00375-06 260 CFM I == 28 \ M OR PURLINS. ROUTE ALL DUCTWORK, PIPING AND CONDUIT AROUND AND THROUGH r 1 'I$ - I �' STRUCTURAL MEMBERS AS REQUIRED. SEE STRUCTURAL DETAILS AND DRAWINGS FOR EXACT 11565 SW Pacific Hwy. --. .� � N05 FMO 12 " - I APPAREL Q IMETHOD OF ATTACHING HANGERS TO BEAMS AND STRUCTURAL MEMBERS. �i • 4 e 1 0 Tigard, OR, 97223 1 Ar 1 ,[ �� f ]1 7� / -4ill • r— K. DO NOT ATTACH SCREWS, NAILS, HANGERS OR FASTENERS OF ANY TYPE TO ROOF DECK. 2018 G o-Fast Remodel +�` i - I ,-- SUPPORT ALL MECHANICAL EQUIPMENT FROM STRUCTURE AND CONTRACTOR-INSTALLED t Alli! I 1 , I - KICKERS ONLY. PROVIDE AND INSTALL INTERMEDIATE KICKERS BETWEEN PURLINS AS III � " iir REQUIRED TO HANG EQUIPMENT AND SHEET METAL DUCTWORK. ECI JOb# 73T02 120 N121 �_ a - P'� "0 a 505 CF _ IT - is) L. ALL TEMPERATURE CONTROLS, EMS CONTROLS AND SMOKE DETECTOR SHUT-DOWN WORK I .� \�� QQ I r1I \\ + ~ ' �l�- i 14„� I SHALL BE COMPLETED BY EMS CONTROLS CONTRACTOR, UNLESS NOTED OTHERWISE. SEE \'` I I ” - COHEM' SHEETS FOR ALL ASSOCIATED WORK. �' I I I 118 1 CO . .p ■ I M. MECHANICAL CONTRACTOR SHALL FIELD-ADJUST ALL DIFFUSERS, REGISTERS AND DRUM Red JJfr ---tiv.witox. , , 0 `l60 CFM ���� .. 5-NA11,41" \ �1 I '■■I.��" — I _ LOUVERS DISCHARGE AIRFLOW AWAY FROM ALL OPEN REFRIGERATED CASES, SWAYING ,4I \�,,, ' i�.�4 �II �IM■IIIfi�II\ ': " _ _ �12"O \12„0 n LOCATIONS ATSIGNAGE, C THE COMPK LETIONREP WOIF CONSGHT TRUCTION LES AND OTHER NOTICEABLE CONFLICTING -► li' f : • l II ..,— _ I I 1,1 I. 0 [1 , ......es -.4, 1FRED MEYER �` I mhos=I ,,r _ �I -0505 CFI4( \\_ I N. MECHANICAL CONTRACTOR SHALL PROVIDE AND INSTALL PERMANENT ENGRAVED 0� r��� 1 1 0 PLASTIC-LAMINATE SIGNS WITH MINIMUM 1”-TALL LETTERING AT ALL ROOFTOP UNITS, �� I it K. �, � ���� � � � sail — � _ � _ 12"0 \12"0 EXHAUST FANS AND HVAC EQUIPMENT LOCATIONS THROUGHOUT ENTIRE BUILDING AND STORES �- h� i` �- '-, \ I �12 CD APPAREL I ROOFTOP. MOUNT PERMANENTLY IN AN APPROPRIATE AND EFFECTIVE LOCATION, WITH UNIT , INC Vir iiii-g i.. N, % Amami., �I Ti 24"x24" LTG I -- _-----------325 CFM STOCKROOM I DESIGNATION AND AREA SERVED SHOWN, PRIOR TO FINAL PUNCH BATE. SEE EMS CONTROL (TYP OF 2) DRAWINGS FOR LABELING OF ALL REMOTE SENSORS, THERMOSTATS AND CONTROL DEVICES. l\\ M ��� 24"x112" STG 3800 SE 22nd Aye - 4%04. r � M�MMi��anM�ME � 0. SUPPLY AND RETURN DUCTWORK FROM ROOFTOP UNITS TO BE INTERNALLY INSULATED A �\ MINIMUM OF TEN FEET FOR SOUND ATTENUATION. ALL SUPPLY AND RETURN DUCTWORK IN+. --611Ik• 7i:._:41......,............7:=............7.7.. .L taMMa EMEMBEIM16"0 I \ j I, 1 -I 1 .�- 1 .. SPACES ABOVE CEILINGS SHALL BE INSULATED PER NEW DUCT INSULATION SCHEDULE ON Portland Oregon =—mss ��__ �.�� �, �._��� �, -� � _ _ SHEET M6.1.1. ----,tit..., Am,... : � _ __ p =. * -_ _ _ 97202 A t t.._ 4.0*is,- �,-iv p i 1 h 4,.I -, ) I 1 iw b- 40 Npv a P. ALL BRANCH DUCTS OFF MAIN DUCT TO BE INSTALLED WITH 45' TIME-AND-A-HALF FITTING, -V ''',, ... 10. ,11110..„ _ ' + �.' i��, - ` _ BELL-MOUTH FITTING, OR SPIN--IN ONLY. NO STRAIGHT TAPS ALLOWED. �� �" ` ON iAir ~ FLEXIBLE DUCT RUNS SHALL BE NO LONGER THAN 6'-0". Rob Law ..:_.0 .411kINIBMQ. �., �.. �. �_ �, ,�. I. f '?►..�._;� -�- ' 503.797.3519 -.iNor �' N ��, r-0 - Alm!I `' - wr _•- � xi j . -- r�►�� i R. MECHANICAL CONTRACTOR SHALL CLEAN, SCRUB AND PRIME FOR FINAL PAINTING BY memo � .g � — ��' .���� _'` �'— ""', ����� �� +� -� f -- - A PAINTING CONTRACTOR ALL VISIBLE DUCTWORK, WHETHER REMAINING, RELOCATED OR NEW. �,F...�_ -�-�- �.11111r _� ...�,.�,. ��- .��, � f r e d m e e r.c o m \� FIELD-VERIFY ALL DUCTS, LOCATIONS AND REQUIREMENTS PRIOR TO BID. ,�� ���rrrn,r S. ALL DUCTWORK SERVING SPACES UNDER THE MEZZANINE MUST BE COORDINATED WITH 1STRUCTURE. BRANCH DUCTWORK TO RUN THROUGH STRUCTURAL JOISTS. 0 KEY NOTES: l \ NEW HVAC PLAN - AREA 7 NOTE: FIELD VERIFY EXISTING HEIGHTS OF EXISTING 1. EXISTING ROOFTOP UNIT OR AIR HANDLING UNIT TO REMAIN. IF AIRFLOW VALUES ARE LISTED ON PLAN, BALANCE CONTRACTOR SHALL BALANCE EXISTING ROOFTOP UNIT OR AIR HANDLING UNIT DUCTWORK SHOWN TO REMAIN ON SALES TO AIRFLOW VALUES LISTED. REPORT ANY DEFICIENCIES TO GENERAL CONTRACTOR AND KROGER These drawings are the property of ArchiTrout '/ FLOOR PRIOR TO BID. RAISE DUCTWORK AS NW PROJECT MANAGER IMMEDIATELY. Design &Architecture, LLC, and are not to be used REQUIRED TO BE SAME ELEVATION AS NEW or reproduced in any manner without prior written NORTHSCALE: 1 /8" - 1 }-0" LIGHTS. 2. EXISTING EQUIPMENT TO REMAIN. permission. © 2017 3. INSTALL BRANCH DUCT OFF MAIN DUCT WITH 45' TIME-AND-A-HALF FITTING OR SPIN-IN ONLY. NO STRAIGHT TAPS ALLOWED. miriP rIn INA 4. NEW TEMPERATURE SENSOR FURNISHED AND INSTALLED BY CONTROLS CONTRACTOR. SEE 'EM' Lai CONTROL DRAWINGS FOR ALL CONTROLS WORK. TEMPERATURE SENSOR SHALL NOT BE LOCATED Permit Set WHERE THE THROW OF A SUPPLY DIFFUSER WILL INTERFERE WITH THE SENSOR. 02 . 22 . 2018 - 5. VAV DIFFUSER, TYPE VAVD. SEE GRILLES, REGISTERS AND DIFFUSERS SCHEDULE ON SHEET M6.2 RI FOR MORE INFORMATION. SET COOLING SETPOINT TO 73'F AND HEATING SETPOINT TO 68'F. _ REVISIONS: _ 6. MOUNT RELATIVE HUMIDITY SENSOR AT 58" A.F.F. ter- r _ .. _ '� tic 7. RUN ALL DUCTWORK LEVEL AT SAME ELEVATION AS EXISTING OR RAISED DUCTWORK. 41 SHEET TITLE: 8. EXISTING THERMOSTAT OR TEMPERATURE SENSOR TO REMAIN. 1 KEY PLAN 9. CONNECT NEW DUCTWORK TO EXISTING DUCTWORK. VERIFY EXISTING DUCT SIZES AND NEW HVAC ELEVATIONS. TRANSITION WHERE REQUIRED. PLAN - AREA 7 PRELIMINARY NOT FOR CONSTRUCTION PERMIT SET: 02 222018 10. LEAVE DUCT OPEN ON THE END OR TOP AS SHOWN AND COVER WITH 1/2"x1/2" WELDED WIRE ' ' MESH WITH REINFORCED STEEL FRAME. 11. EXISTING CO2 SENSOR TO REMAIN. FIELD VERIFY EXISTING LOCATION. DRAWN BY: JJR 12. STAND-ALONE DIGITAL, NIGHT-SETBACK CAPABLE, PROGRAMMABLE THERMOSTAT FURNISHED BY CHECKED BY: CLM CONTROLS CONTRACTOR. SEE 'EM' CONTROL DRAWINGS. 13. NEW RELATIVE HUMIDITY SENSOR FURNISHED BY CONTROLS CONTRACTOR. SEE 'EM' CONTROLS - DRAWINGS. NI 1 7 14. BALANCE EXISTING SUPPLY REGISTER, RETURN OR EXHAUST GRILLE TO AIRFLOW INDICATED. ■ • • ALIGN ADJUSTABLE BLADES FOR EVEN DIFFUSION. 18 9 9. 1 19. - @ 211 22 --- - n n L,--:: --J tfALANI t IU J,UUU Lr M �. N 32 x24 \ -o oo __ -- \-28"x16" 0 ..rI _ . ..... p [� ---4----- �_ M FROM AC-17. ° °O 1 ...., ii ._ L.....i__\.1,0/Npep_y - oi. ■i - - -� ,, 1 I\ U M. r 1 PI P9 1 ,_, , :1(1) 4 — — — — — 114 tr=11o� o ' ■!■ i r � AI E1 � � as ��i )(g �! 48"x24" RG o o • tLII � www■ 2,500 CFM U eXIl i1E_i ft 111 \28"x16" AM - \,ISII \.,;Ii -71 \ I it 1 `��lil " 11 l:I j -� r-: i1�I •~ — 6- ` .-.J r.i ae Irk�■ 1.1�,11I IN �� _'_,L.' i L�1i 11 11 111 11 `IIIA! i n hi ll ILII I l n lit 11 l ,.._, „, t. Y ._ �'._rel ill, � Iiii I11 th Ia I W '.. ■■ u i L II-71� ItEl� ,l■■ 1I r■ ■ `p11 ` 11 1&Ii \ 1 111 !11 Li 1■iI ■ r--taiiil r_- -� `i I `II a Ii ill II Ilii i `i i MI trei i . (111 ilik I♦ _ I I LNik- CHE KLANES 11 $ — OP* 11 L _l I I 20"x10" DL -- .-- -- • � 500 CFM \ �` �J S CD (TYP OF 6) - 4114/:)N �J CFM(TYP OF 6) AC-14,15,16,17 \\ 1I: iirlw-0(1YP) 7-1 0'10 EMIIIMIlliral :EX`STING i : /.- /1235 24"x24" RG •—�-� °O C1,950 CFM I 16"0 20"0 1 L Ito 1 EXISTING 1-411 . O 1 , I \ / 1 \ 0 / 1 \ N FREDMEYER00375 ___:)__ � �,.- X10"0 EXISTING I ' _ __ „� L-1-17NOTE: TI G A R D -- ,, `x. E., ' i (Q of -0 r D1�. �C� - D �_ ■' FIELD VERIFY EXISTING HEIGHTS OF EXISTING rr�,r' �I " — _ I " �� �� - FLOOR PRIOR TO BID. RAISE DUCTWORK AS •�� © 22DUCTWORK SHOWN TO REMAIN ON SALES ''' -•I . I -II1f I '�' ( EXISTING 0n n REQUIRED TO BE SAME ELEVATION AS NEW 701-00375-06 22 RA WITH 20 x48 P N . EXISTING 20 x10 DL OPENING IN TOP. LIGHTS. ■� .2"0 _ - � ►j ; 10"0 RTF0 1 800 CFM BALANCE TO 3,000 CFM 11565 SW Pacific Hwy. 1 " co I IIIIIiiIN IIM-_ - - .. . , a - __Ti g a rd l R j 97 3 - -� �- 8 24 x 12 LTG •� ,• �_ I 48"x24" LRG ,�� , = �_ 2018 Go-Fast Remodel / .�rr�-�I�i.wl�Irs■ ._- I I ilI"' _ 1,,,,,,s\.... 1 _ _li_ � r--� ,� �i►% ,�� _ 3,000 c1 M O' 0 ' '- 1 \ J/ ath.,.gt 1 , ■�■=T N , , : 1 RIF ECI Job# 73102 Eil CHASE - t1:2r '" 00 s iiry BANK +� - - 1 4a multrIm„.. Fred Meyer \ [1B L ...M_Ad p . ! \� EXISTING Y\ �_ IT I „ , : I R J I ._. in . 1. 1 4la \ /-1 ro I 1 1 H II 11 ,' 7:111 _ � � ` .. % I "YI LD 1 r �, ~' \ 10"I 1=1 I 1 CIn 2 I i - '` '* ,r- -i ,> A% A III F i �i _ .ri 1 ,..,,J - i „� k t.- I�l �{E)18"o I 1>T 0 Baa CFM 0 i i ► - �,. 17l: s. ` III �` I o 12 x12" STG _ ( I-Illllu+ a II 1 , 7 H 8 0�� n 5 fi:.. II r_r s i F i r wprilti:i T - 540 CFM ~ EXISTING -. \ s _ -�:,� ' Ourv ' Il�ili �1�-,., . $ H I I _ , . I 8 FRED MEYER " • _ w II Ilr.I.� nil - 8"0 LCD KEY PLAN 8 �� DEC �` ;OKI- �`" �\ '` z '� (� \ %��� I 22"� 18"I�l I I _ I '� 6 i �� i lii w 200 CFM ■ - ® - 2 \ • EXISTING" '•'E-' - Im, 4 '� ;l T — _ i It-1 1STORES INC !. Icu 1 _ ''— It 10"0 CD , " " ,,,,,,,,,.,...,,I,...„..., _ •■"V, - '. 2 n.J 1_ - .I215 CFM x12 CD FLORAL - �' n �. r �� , PHARMACY 27o cFM COOLER �.� ��� I �. =i 1 i n >� ��' I I I ,, - ply (TYP OF 2) ' OF } - E 22 - �: �. . E 20"-- 14"� ►� �` _I 1 I.I f l , . ,,� W ,Q —r A 1 ( � 1+ ._ - ) F ,�I f �1� _ _� _ f _ _ 3800 SE 22nd Ave __ . A s4 - . . I-- I _ W-----,, - .. -- Portland Oregon 111.11 �� .�__� _ _ _=�._ . �I�,� �,; - _ _i w�� 7+ �1 _- LTi�!, _ _ - -_ate _____ EJ � �� �;� �T ,� = _ � a�i �1 �� ;. p � '��� ��F 24"x 12" LTG ���1�� �� 97202 - -‘56' __I.,* .". wilaw.—...•q irsivivp-,-- hili ��o. _ MlI �� +f � ,- i� �. BOTTLE �►- _� .� �-lle .- �-PS. ��414" 1�i.�►� �� ��` �. �� STORAGE I '� i . r .� ■����.�;��_- ..■_=Ccs• x.. .„.,..47."--.04111P,. �� 40. �1 la � 4 �+ #411, A.. -, .. IP' N. all''-ir 4111611W- VAL. 0. " Allt% -lir �. Rob Law �� 4441, :a: ri � .��• _ __.:� ��- � 11* --� .=� __ -.�� ��.� . ���� - , � � - ---- - - A 503.797.3519 �_ ��! �� �434111%. #'4,- <�i '- f111N— f red m eye r.co m I 0 KEY NOTES: �\ NEW HVAC PLAN - AREA 9 1 1. EXISTING ROOFTOP UNIT OR AIR HANDLING UNIT TO REMAIN. IF AIRFLOW VALUES ARE LISTED ON 4/ PRELIMINARY NOT FOR CONSTRUCTION PERMIT SET. 02/22/2018 PLAN, BALANCE CONTRACTOR SHALL BALANCE EXISTING ROOFTOP UNIT OR AIR HANDLING UNIT NORTH These drawings are the property of ArchiTrout TO AIRFLOW VALUES LISTED. REPORT ANY DEFICIENCIES TO GENERAL CONTRACTOR AND KROGER , H. ALL DIMENSIONS ARE LISTED IN INCHES UNLESS NOTED OTHERWISE. ALL DUCTWORK Design &Architecture, LLC, and are not to be used NW PROJECT MANAGER IMMEDIATELY. N E V Vn, GENERAL NOTES: DIMENSIONS ARE INSIDE CLEAR. O. SUPPLY AND RETURN DUCTWORK FROM ROOFTOP UNITS TO BE INTERNALLY INSULATED A or reproduced in any manner without prior written 2. EXISTING EQUIPMENT TO REMAIN. MINIMUM OF TEN FEET FOR SOUND ATTENUATION. ALL SUPPLY AND RETURN DUCTWORK IN permission. A. NEW EQUIPMENT AND DUCTWORK SHOWN DARK NIdLS)LID1 718,EQIJIPIINT le DUCTWORK I. HVAC CONTRACTOR SHALL FIELD-COORDINATE ALL CONDITIONS, UNIT LOCATIONS, SPACES ABOVE CEILINGS SHALL BE INSULATED PER NEW DUCT INSULATION SCHEDULE ON © 2017 3. INSTALL BRANCH DUCT OFF MAIN DUCT WITH 45' TIME-AND-A--HALF FITTING OR SPIN-IN ONLY. SHOWN LIGHTER AND SOLID TO REMAIN. OBSTRUCTIONS AND DUCTWORK INSTALLATION PRIOR TO DUCT FABRICATION. TRANSITION AND SHEET M6.1.1. NO STRAIGHT TAPS ALLOWED. OFFSET DUCTWORK, AS REQUIRED, TO MAKE FIT IN CEILING SPACES AND FIELD CONDITIONS. B. ALL ROOF PENETRATIONS SHALL BE COMPLETED IN ACCORDANCE WITH ROOFING SYSTEM DUCTWORK FABRICATED BY THE HVAC CONTRACTOR PRIOR TO FIELD COORDINATION AND P. ALL BRANCH DUCTS OFF MAIN DUCT TO BE INSTALLED WITH 45' TIME-AND-A-HALF FITTING, 4. NEW TEMPERATURE SENSOR FURNISHED AND INSTALLED BY CONTROLS CONTRACTOR. SEE 'EM' REQUIREMENTS AND ROOF MANUFACTURER'S INSTRUCTIONS. COORDINATE ALL WORK WITH CONFLICT RESOLUTION SHALL BE AT THE RESPONSIBILITY AND COST OF THE HVAC BELL-MOUTH FITTING, OR SPIN-IN ONLY. NO STRAIGHT TAPS ALLOWED. Pe1rI� I+l Set ROOFING CONTRACTOR. CONTRACTOR. OWNER SHALL NOT BE RESPONSIBLE FOR SHOP-FABRICATED DUCTWORK CONTROL DRAWINGS FOR ALL CONTROLS WORK. TEMPERATURE SENSOR SHALL NOT BE LOCATED SIZED DIRECTLY FROM THE HVAC DRAWINGS. Q. FLEXIBLE DUCT RUNS SHALL BE NO LONGER THAN 6'-0". WHERE THE THROW OF A SUPPLY DIFFUSER WILL INTERFERE WITH THE SENSOR. C. CONTRACTOR SHALL VERIFY EXACT HEIGHTS OF ALL CEILINGS & DECOR ITEMS PRIOR TO 02 . 22 . 2018 5. VAV DIFFUSER, TYPE VAVD. SEE GRILLES, REGISTERS AND DIFFUSERS SCHEDULE ON SHEET M6.2 START OF WORK. SEE ARCHITECTURAL SHEETS FOR DETAILS AND CONSTRUCTION. J. DO NOT CUT, DRILL HOLES OR REMOVE ANY PORTION OF STRUCTURAL MEMBERS, BEAMS R. MECHANICAL CONTRACTOR SHALL CLEAN, SCRUB AND PRIME FOR FINAL PAINTING BY FOR MORE INFORMATION. SET COOLING SETPOINT TO 73'F AND HEATING SETPOINT TO 68'F. COORDINATE EXACT DUCTWORK INSTALLATION WITH CEILING & DECOR AND STRUCTURE, AS OR PURLINS. ROUTE ALL DUCTWORK, PIPING AND CONDUIT AROUND AND THROUGH PAINTING CONTRACTOR ALL VISIBLE DUCTWORK, WHETHER REMAINING, RELOCATED OR NEW. REQUIRED. STRUCTURAL MEMBERS AS TO BID. METHOD OF ATTACHING HANGERS TO BEAMS AND STRUCTURAL MEMBERSRED. SEE STRUCTURAL DETAILS AND . S. FOR EXACT S. ALL DUCTWORK FIELD-VERIFY LSERVINGS'S AL CES UNDER THE ATIONS AND REQMEZZAN NE MUSTUIREMENTS PRIOR B COORDINATED WITH REVISIONS 6. MOUNT RELATIVE HUMIDITY SENSOR AT 58" A.F.F. D. SEE ELECTRICAL LIGHTING SHEETS FOR EXACT LOCATION OF ALL LIGHT FIXTURES. STRUCTURE. BRANCH DUCTWORK TO RUN THROUGH STRUCTURAL JOISTS. COORDINATE EXACT DIFFUSER AND GRILLE LOCATIONS WITH LIGHTING FIXTURES, AS K. DO NOT ATTACH SCREWS, NAILS, HANGERS OR FASTENERS OF ANY TYPE TO ROOF DECK. 7. RUN ALL DUCTWORK LEVEL AT SAME ELEVATION AS EXISTING OR RAISED DUCTWORK. REQUIRED. INSTALL AND MAINTAIN A MINIMUM OF 36" FROM LIGHT FIXTURE IN ALL OPEN SUPPORT ALL MECHANICAL EQUIPMENT FROM STRUCTURE AND CONTRACTOR-INSTALLED SHEET TITLE: 8. EXISTING THERMOSTAT OR TEMPERATURE SENSOR TO REMAIN. AREAS WITHOUT DROP CEILINGS. KICKERS ONLY. PROVIDE AND INSTALL INTERMEDIATE KICKERS BETWEEN PURLINS AS REQUIRED TO HANG EQUIPMENT AND SHEET METAL DUCTWORK. NEW HVAC 9. CONNECT NEW DUCTWORK TO EXISTING DUCTWORK. VERIFY EXISTING DUCT SIZES AND E. INSTALL ALL DUCTWORK AS HIGH AS POSSIBLE WHILE COORDINATING WITH ALL OTHER L. ALL TEMPERATURE CONTROLS, EMS CONTROLS AND SMOKE DETECTOR SHUT-DOWN WORK YY ELEVATIONS. TRANSITION WHERE REQUIRED. TRADES. OFFSET AND TRANSTDR DUCTWORK BETWEEN AND BENEATH STRUCTURAL SHALL BE COMPLETED BY EMS CONTROLS CONTRACTOR, UNLESS NOTED OTHERWISE. SEE PLAN - AREA 9 MEMBERS, WHERE REQUIRED. DROP BRANCH DUCTS DOWN TO DIFFUSERS AND GRILLES. 10. LEAVE DUCT OPEN ON THE END OR TOP AS SHOWN AND COVER WITH 1/2"x1/2" WELDED WIRE 'EM' SHEETS FOR ALL ASSOCIATED WORK. MESH WITH REINFORCED STEEL FRAME. F. ALL DUCTWORK SHALL MEET SMACNA'S "HVAC DUCT CONSTRUCTION STANDARDS - METAL M. MECHANICAL CONTRACTOR SHALL FIELD-ADJUST ALL DIFFUSERS, REGISTERS AND DRUM AND FLEXIBLE", CURRENT EDITION. DUCT GAUGES, REINFORCEMENTS, METHODS OF LOUVERS DISCHARGE AIRFLOW AWAY FROM ALL OPEN REFRIGERATED CASES, SWAYING 11. EXISTING CO2 SENSOR TO REMAIN. FIELD VERIFY EXISTING LOCATION. CONNECTION, TRANSITIONS AND CONSTRUCTION WILL BE FIELD-VERIFIED, MEASURED AND SIGNAGE, CHECK STAND/PREP WEIGHT SCALES AND OTHER NOTICEABLE CONFLICTING DRAWN BY: JJR INSPECTED FOR COMPLIANCE. DUCTWORK NOT MEETING SMACNA'S STANDARDS WILL BE LOCATIONS AT THE COMPLETION OF CONSTRUCTION. 12. STAND-ALONE DIGITAL, NIGHT-SETBACK CAPABLE, PROGRAMMABLE THERMOSTAT FURNISHED BY REMOVED AND REPLACED AT CONTRACTOR'S EXPENSE. SEE THE SPECIFICATIONS FOR THE CONTROLS CONTRACTOR. SEE 'EM' CONTROL DRAWINGS. REQUIRED PRESSURE CLASSIFICATION FOR ALL DUCTWORK. CONTRACTOR SHALL VERIFY ALL N. MECHANICAL CONTRACTOR SHALL PROVIDE AND INSTALL PERMANENT ENGRAVED CHECKED BY: CLM REQUIREMENTS PRIOR TO SUBMITTALS OR DUCT FABRICATION AND GIVE WRITTEN PLASTIC-LAMINATE SIGNS WITH MINIMUM 1"-TALL LETTERING AT ALL ROOFTOP UNITS, 13. NEW RELATIVE HUMIDITY SENSOR FURNISHED BY CONTROLS CONTRACTOR. SEE 'EM' CONTROLS DOCUMENTATION OF COMPLIANCE IN ORIGINAL PRODUCT SUBMITTALS. EXHAUST FANS AND HVAC EQUIPMENT LOCATIONS THROUGHOUT ENTIRE BUILDING AND DRAWINGS. ROOFTOP. MOUNT PERMANENTLY IN AN APPROPRIATE AND EFFECTIVE LOCATION, WITH UNIT G. ALL DUCTWORK IN EXPOSED SALES AREAS SHALL BE SHEET METAL ONLY, NO FLEX DUCT DESIGNATION AND AREA SERVED SHOWN, PRIOR TO FINAL PUNCH DATE. SEE EMS CONTROL 14. BALANCE EXISTING SUPPLY REGISTER, RETURN OR EXHAUST GRILLE TO AIRFLOW INDICATED. ALLOWED. FINAL CONNECTIONS TO DIFFUSERS, GRILLES AND REGISTERS SHALL BE SHEET DRAWINGS FOR LABELING OF ALL REMOTE SENSORS, THERMOSTATS AND CONTROL DEVICES. ALIGN ADJUSTABLE BLADES FOR EVEN DIFFUSION. METAL DUCT ONLY. SUPPORT DUCTWORK PER SMACNA AND CODE. FURNISH WITH PAINT-LOC M 1 • 1 • 9 FINISH OR PRIME FOR PAINTING. ABBREVIATIONS N SYMBOL DESCRIPTION EXISTING ROOFTOP HEATING & AIR CONDITIONING UNIT SCHEDULE 000 v A.G.A. AMERICAN GAS ASSOCIATION W HEATING COOLING NOMINAL AFF ABOVE FINISHED FLOOR SYMBOL LOCATION TYPE CFM SPE B.H.P. ELECT. O.D.A MANUFACTURER DATE WEIGHT 'a GAS INPUT GAS OUTPUT AFUE BTU TOTAL BTU SENSIBLE SEER CFM 1 TONS V o § PACKAGED S � AFG ABOVE FINISHED GRADE (°G� ALE ROOFTOP UNIT 3,000 0.55" 1.0 MG460/60/326 120,000 97,200 81% 86,000 63,600 - 4� YCDO9TRANE�1D4LABE 2001 MODEL1,190# 7.5 BHP BRAKE HORSEPOWER 14. DOWN FLOW CU PACKAGED 460/0/3 205,000 166.000 - TRANE; MODEL 1.190 w cl °' BTU BRITISH THERMAL UNIT ALE ROOFTOP UNIT 3,000 0.55" - MCA 21.6 81% 86,000 63,600 450 YCD491D4HABE 2001 # 7.5 U �Q, 15 DOWN FLOW A M CAP CAPACITY AC ALE PACGED ROOFTOP UNIT 3,000 0.75" - 460/60/3 205,000 166,000 B1% 86,400 53,600 - 45O TRANS; MODEL 2001 1,1901 7.5 o CENT CENTRIFUGAL (16) DOWN FLOW MCA: 2 .6 YCD091 D4HABEI': 11 O CFM CUBIC FEET PER MINUTE (AIRFLOW) m ALE PACKAGED ROOFTOP UNIT 10,000 0.8" - 460/60/3 400,000 324,000 81% 300,000 236,000 - 2,400 TRANS; MODEL 2001 2,7001 25 ° CHAR CHARACTERISTICS, ELECTRICAL W DOWN FLOW MCA: 5 YCD301C4HABAw gg ate. CONT CONTINUATION /AC\ PACKAGED _ 460/60/3 400,000 324,000 - TRANE; MODEL \18/ GROCERY / ALE ROOFTOP FLOW UNIT 10,000 0.$" MCA: 5681% 300,000 236,0001,400 YCD301C4HABE 2001 2,7001 25 COORD COORDINATE PACKAGED 460/60/3 MON MODEL CO2 CARBON DIOXIDE SENSOR (IAO) ® CUSTOMER SERVICE ROOFTOPFLOUNIT 1,950 4.5" - MC14 �'� 81% 55,180 49,430 - 380 RQ-005-3--V-COOT-212 2013 9�# 5 CO CARBON MONOXIDE SENSOR (IAC)) PACKAGED 460/60/3MON MODEL 1116.441k PEM ELECTRONICS ROOFTOP UNIT 5,200 0.5' - / 195,000 156.000 81% 141,560 127,190 - 710 2013 1,9541 13 DB DRY BULB ('F) 41 DOWN FLOW MCA 3RN-013-3-D-CAD2-2F2 `P DN DOWN O TAB CONTRACTOR SHALL BALANCE EXISTING HVAC UNITS TO ODA CFM LISTED IN THIS COLUMN. (E) EXISTING O TAB CONTRACTOR SHALL BALANCE EXISTING HVAC UNITS SUPPLY AND RETURN AIR TO CFM LISTED ON PLANS. �� EA EXHAUST AIR O ALL EQUIPMENT TO REMAIN UNLESS OTHERWISE NOTED ORSEAT ENTERING AIR TEMPERATURE ('F) 0 MECHANICAL CONTRACTOR TO PROVIDE FULL INSPECTION AT BEGINNING OF PROJECT ON ROOFTOP UNIT IN ALL HEATING AND COOLING MODES TO ENSURE PROPER OPERATION. COMPLETE AND SUBMIT WRITTEN "AIR CONDITIONING SYSTEM EFF EFFICIENCY TEST START-UP CHECK UST FORM" AS INCLUDED IN SPECIFICATION SECTION 23 74 13 WITHIN FIRST FOUR WEEKS OF CONSTRUCTION. PROVIDE FULL MAINTENANCE AND SERVICE ON AC UNIT INCLUDING CLEANING FAN, HOUSING, EER ENERGY EFFICIENCY RATIO SQUIRREL CAGE, MOTOR, CONDENSER FINS, REPLACE FILTER. FURNISH NEW FAN BELTS AS REQUIRED, LUBRICATE, INSPECT EXISTING SMOKE DETECTOR FOR PROPER OPERATION, SEAL AND GASKET ANY DAMAGE TO EXTERIOR PANELS AS NECESSARY. REPORT ANY MAINTENANCE ISSUES OR DEFICIENCIES TO KROGER NW PROJECT MANAGER ALONG WITH SUBMISSION OF WRITTEN REPORT IMMEDIATELY.' ELEG ELECTRICAL FRED MEYER 00375 ESP EXTERNAL STATIC PRESSURE GRILLE, REGISTER AND DIFFUSER SCHEDULE EXISTING EXHAUST FAN SCHEDULE ETC ETCETERA TIGARD EX EXISTING SYMBOL DESCRIPTION MANUFACTURER & MODEL REMARKS SYMBOL LOCATION TYPE C.F.M. SPE WATT H P CHAR. CONTROL SONES MANUFACTURER CEILING - CAPTNEAIRE• MODEL CFA150CA P N: 701-00375-06 FD FIRE DAMPER LOUVERED CEILING DIFFUSER 4-WAY TITUS MODEL TDC W/ TYPE 1 BORDER FOR SURFACE MOUNT, DEMO iii• _ PWARAISFX MIKE 025• 115/00/1 - L-16Ff1'J FACTORY ROOF CAP 1 FLA FULL LOAD AMPERAGE CD AIRFLOW, ROUND NECK, SURFACE DISCHARGE PATTERN A4 FOR 4-WAY THROW. NECK SIZE SAME EXHAUST FAN .03 11565 SW Pacific Hwy. MOUNT AS DUCT RUNOUT SIZE. WITH FACE-OPERABLE OPPOSED BLADE y' FSD FIRE SMOKE DAMPER DAMPER, MODEL AG-95. FACTORY WHITE FINISH. 1. RMANUFACTUREREMOVE AND 1SCRoD oFEWARNRAG EQUIPMENT,NTY AND INSTRUCTIONS.K AND ALL ASSOCIATED ACCESSORIES. CAP ALL ROOF PENETRATIONS WATERTIGHT PER ROOF Tigard, OR, 97223 GA GAUGE LOUVERED CEILING DIFFUSER, 4-WAY TITUS MODEL TDC W/ 24"x24" TYPE 3 BORDER FOR LAY-IN LCD AIRFLOW, ROUND NECK, LAY-IN CEILING, DISCHARGE PATTERN A4 FOR 4-WAY THROW. 18"x18" GPM GALLONS PER MINUTE PAN WITH ROUND NECK SIZE AS SHOWN ON PLANS. If HORSEPOWER 2018 Go-Fast Remodel VARIABLE AIR VOLUME SUPPLY ACUTHERM MODEL TF-HC W/ 24"x24' BORDER FOR LAY-IN HX HEAT EXCHANGER VAVD DIFFUSER CEILING, DIGITAL WALL ADJUSTER, 4-WAY THROW. NECK SIZE AS ECI Job# 73T02 IAO INDOOR AIR QUALITY SHOWN ON PLANS. FACTORY WHITE FINISH. IEQ INDOOR ENVIRONMENTAL QUALITY TITUS MODEL DL WITH ADJUSTABLE CORE AND BLADES WITH kW KILOWATT (POWER) DL SUPPLY DRUM LOWER TYPE 1 BORDER FOR FREE STANDING INSTALLATION. SIZE AS SHOWN ON PLANS. FACTORY WHITE FINISH. Fred Meyet LAT LEAVING AIR TEMP MAX MAXIMUM RG RETURN AIR GRILLE TITUS MODEL 50R W/ TYPE 1 BORDER FOR SURFACE MOUNT. (1) MBH 1000 BTUs/ HOUR NECK SIZE AS SHOWN ON PLANS. FACTORY WHITE FINISH. MIN MINIMUM FRED MEYER FINISH. TITUS MODEL 50R W/ 24"x24" OR2 x TYPE 3 BORDER STORES, I N C MODS MODIFICATIONS LRG LAY-IN CEILING RETURN AIR GRILLE FOR LAY-IN CEILING, AS SHOWNON PLANS. FACTORY WHITE (1) NO. OR # NUMBER N.T.S. NOT TO SCALE TFTUS MODEL LTG LAY-IN CEILING TRANSFER AIR GRILLE FOR LAY-IN CEILING,/ 4OR 2 4"x12" TYPE 3 BORDER 3800 SE 22nd Ave ASSHOWNONPLANS. FACTORY WHITE (1) OA OUTSIDE AIR (FRESH AIR) FINISH. Portland, Oregon OAT OUTSIDE AIR TEMPERATURE ('F) 97202 TITUS MODEL 355ZRS W/ TYPE 1 BORDER FOR SURFACE OB OPPOSED BLADE STG SIDEWALL TRANSFER GRILLE MOUNT, 1/2" BLADE SPACING AT 0' DEFLECTION. SIZE AS (1) PD PRESSURE DROP SHOWN ON PLANS. FACTORY WHITE FINISH. Rob Law PRV PRESSURE REDUCING VALVE 1. PAINT VISIBLE DUCTWORK BEHIND GRILLES FLAT BLACK 503.797.3519 PSI POUNDS PER SQUARE INCH (PRESSURE) f re d m eye r.co m RA RETURN AIR REF REFRIGERATION HVAC SYMBOLS & ABBREVIATIONS REFRIG REFRIGERANT REQ'D REQUIRED 4 SUPPLY AIR RISERIL IL NEW DUCTWORK L MANUAL VOLUME DAMPER. These drawings are the property of Arch iTrout RH RELATIVE HUMIDITY SEE DETAIL 6/M300. DETAIL FOR ROUND DUCT INSTALLATION Design&Architecture,LLC,and are not to be used RPBP REDUCED-PRESSURE BACKFLOW PREVENTER A RETURN AIR RISER or reproduced in any manner without prior written RPM REVOLUTIONS PER MINUTE MANUAL VOLUME DAMPER WITH REMOTE ACTUATOR FOR ROUND DUCT. SEE PLANS permission. CONCEALED DAMPER FOR DUCT SIZES O 2017 S SENSOR (SEE SPECS) A EXHAUST AIR RISER LOCATIONS ALL NEW DRUM LOUVERS/REGISTER SHALL HAVE 45' LATERAL TAKE-OFF SA SUPPLY AIR SQUARE-TO-ROUND FITTING FROM MAIN DUCT (TYPICAL) - WWI- FLEXIBLE DUCT (6'0" MAX) TRANSITION Permit S e t SD SMOKE DETECTOR (IN RETURN DUCT) �� MANUAL BALANCE \ 02.22.2018 SEER SEASONAL ENERGY EFFICIENCY RATIO SPIN-IN FITTING W/ 45' AIR FOUR-WAY DIFFUSER DAMPER (TYPICAL} SPE STATIC PRESSURE EXTERNAL -117 EXTRACTOR AND MANUAL VOLUME DAMPER. SUPPLY DRUM LOUVE ,. i-- SPT STATIC PRESSURE TOTAL -�� �' W- OR REGISTER \ ! REVISIONS TWO-WAY DIFFUSER S/T SENSIBLE TO TOTAL COOLING RATIO J (TYPICAL) �..\ �'� 1� SPIN-IN FITTING W VOLUME DAMPER. 1Z1NEW RETURN GRILLES MAINTAIN MINIMUM OF 2 ��, T-STAT THERMOSTAT (SEE SPECS) DUCT WIDTHS BETWEEN �`� 4 'I TSP TOTAL STATIC PRESSURE EXHAUST GRILLE DRUM LOUVER/REGISTER -"\,-- ® AND ADJACENT DUCT, BEAM TYP TYPICAL OR OBSTRUCTION 160' (TYP.) VOL VOLUME DETAIL CALLOUT EQUIPMENT TAG BOLST BYY COCTRROLS C OCONTRACTOR. W/ WITH NPHASE LOCATE IN RETURN DUCT El CARBON DIOXIDE MONITORING DETAIL FOR RECTANGULAR DUCT INSTALLATION WB WET BULB ('F) lio(DETAIL NUMBER EQUIPMENT TYPE STATION REFERENCE Q EQUIPMENT 0 THERMOSTAT RECTANGULAR DUCT. SEE SOME mons USTED W NS LEcoIt MAY Not APPcM+nnw 1116 PROJECT'S ROOF TAG NUMBER PLANS FOR DUCT SIZES SCOPE THIS UST r;FOR CENERSC PURPOSES OILY AND IS NOT PROJECT-SPEgFlC. SHEET 0 TEMPERATURE SENSOR LOCATION /MOUNT CENTER OF NEW ALL NEW DRUM LOWERS/REGISTER DRUM LOWER IN SHALL HAVE 45' LATERAL TAKE-OFF CENTERLINE OF FITTING FROM MAIN DUCT (TYPICAL) RECTANGULAR DUCT MANUAL BALANCE NEW DUCT INSULATION SPECIFICATIONS DAMPER (TYPICAL) . 'i DUCT OTHER INSULATION MI E ��`,\\\ •�PP------.„ DUCT TYPE LOCATION REQUIREMENTS R-VALUE �25'�/vI•• \` •I � \ •� SUPPLY, OUTSIDE THE BUILDING, IN COLD ATTICS, MAINTAIN MINIMUM OF 2 U DUCT WIDTHS BETWEEN RETURN CRAWL SPACES & GARAGES, WITHIN A APPROVED WEATHER BUILDING ENVELOPE ASSEMBLY. PROOF BARRIER R-8 DRUM LOWER/REGISTER AND ADJACENT DUCT, BEAM OR OBSTRUCTION 90' (TYP.) SUPPLY DRUM LOUVE OUTSIDE AIR ALL LOCATIONS SEE ENERGY CODE R-8 NOTES: OR REGISTER. SET TO SHEET TITLE: MINIMUM DRUM LOUVER OR DUCT 20 FROM HORIZONTAL SUPPLY, RETURN, UNCONDITIONED SPACES INCLUDING ABOVE HEIGHT SHALL BE A MINIMUM OF DISCHARGE (TYPICAL) OUTSIDE AIR LAY-IN & SHEET ROCK CEILINGS. SEE ENERGY CODE R-6 16'0" A.F.F. NO EXCEPTIONS. FIELD HVAC COORDIF A NO OUVERSAAND ATE EXACT REGISTERS TON OWITHUGHT DATE: 09.01.16 SUPPLY, RETURN WITHIN CONDITIONED SPACE - INSULATION FIXTURES AND SIGNAGE/GRAPHICS. EXPOSED DUCT AND DRUM SCALE: NONE SCHEDULES & NOTES: (4) REQUIRED ADJUST DISCHARGE AND AIRFLOW LOUVER SECTION DRAWN; JJR AFTER SUBSTANTIAL COMPLETION AND DETAILS 1. ALL NEW AND RELOCATED DUCTS SHALL MEET OR EXCEED THE SPECIFICATIONS LISTED. PUNCH LIST FOR CONFUCTS AND EXISTING, REUSED DUCTS ARE NOT REQUIRED TO MEET THE SPECIFICATIONS LISTED SWAYING EQUIPMENT KROGER NW STANDARD DETAIL NW -HSD--315 2. REQUIREMENTS APPLY TO THE DUCT TYPE LISTED WHETHER HEATED OR MECHANICALLY ORIGINAL ISSUE DATE 06/27/06 COOLED. MECHANICALLY COOLED DUCTS REQUIRING INSULATION SHALL HAVE A VAPOR RETARDER, WITH A PERM RATING NOT GREATER THAN 0.5 AND ALL JOINTS SEALED 3. ALL SPECIFICATIONS AND REQUIREMENTS LISTED SUPERSEDE AND OVERRIDE ALL REQUIREMENTS LISTED IN SPECIFICATIONS BOOK. 4. IF SUPPLY AIR IS <55'F OR >105'F, SUPPLY DUCT SHALL BE INSULATED WITH R-6 INSULATION. INSULATION TYP S: MINIMUM DENSITIES AND OUT OF PACKAGE THICKNESS. NOMINAL R-VALUES ARE FOR THE INSULATION AS INSTALLED AND DO NOT INCLUDE AIR FILM RESISTANCE. INSTALLED: R-6 2.0 INCH 0.75 LB/CU.FT. MINERAL OR GLASS FIBER BLANKET, 1.5 INCH 1.5 TO 3.0 LB/CU.FT. DUCT LINER, MINERAL OR GLASS FIBER BLANKET, 1.5 INCH 3.0 TO 7.0 LB/CU.FT. MINERAL OR GLASS FIBER BOARD OR EQUIVALENT TO PROVIDE AN INSTALLED DRAWN BY: JJR TOTAL THERMAL RESISTANCE OF AT LEAST R-6. R-8 3.0 INCH 1.0 LB/CU.FT. MINERAL OR GLASS FIBER BLANKET, 2.0 INCH 1.5 TO 3.0 CHECKED BY: CIM LB/CU.FT. DUCT LINER, MINERAL OR GLASS FIBER BLANKET, 2.0 INCH 3.0 TO 8.0 LB/CU.FT. MINERAL OR GLASS FIBER BOARD OR EQUIVALENT TO PROVIDE AN INSTALLED TOTAL THERMAL RESISTANCE OF AT LEAST R-8. PRELIMINARY NOT FOR CONSTRUCTION PERMIT SET: 02/22/2018 M6 . 1