Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans (46)
FPS2O19-00129 Wheelock ExcederTM Series l/ COOPER Notification RECEIVED EleEi Strobe, Horn Strobe, and Horn SEP 3 0 2019 Notification Appliances CITY OF TIGARD 11 • F l • IN Ceiling all Description: The Wheelock®Excederm Series of notification appliances feature a sleek modern design that will please building owners with reduced -Save up to 48% in current draw* total cost of ownership. Installers will benefit from its comprehensive feature list, including the most candela options in one appliance, low current draw, no tools needed for setting changes, voltage test - Up to 9 models now in 1 appliance points, 12/24 VDC operation,universal mounting base and multiple mounting options for both new and retrofit construction. -Save up to 14% cost of installation** The Wheelock® ExcederTM Series incorporates high reliability and high efficiency optics to minimize current draw allowing for a greater number of appliances on the notification appliance circuit.All strobe models feature an industry first of 8 candela settings on a single 0 Sleek Modern Aesthetics appliance.Models with an audible feature 3 sound settings(90,95, 99 dB).All switches to change settings, can be set without the use of a tool and are located behind the appliance to prevent tampering. tiiir;*4 Finger Slide Switches Wall models feature voltage test points to take readings with a voltage meter for troubleshooting and AHJ inspection. The Wheelock® ExcederTM Series of wall and ceiling notification Voltage Test Points appliances feature a Universal Mounting Base (UMB) designed to simplify the installation and testing of horns, strobes, and combination horn strobes. The separate universal mounting 12 4 Multiple Voltages base can be pre-wired to allow full testing of circuit wiring before VDC the appliance is installed and the surface is finished. It comes complete with a Contact Cover for protection against dirt,dust, paint 3 Audible Settings and damage to the contacts. The Contact Cover also acts as a till 90, 95, de shunting device to allow pre-wire testing for common wiring issues. The Contact Cover is polarized to prevent it from being installed incorrectly and prevents the appliance from being installed while U8 Candela Settings '** 0 it is on the UMB. When the Contact Cover is removed the circuit wall-15/1575/30/75/95/110/135/185 will show an open until the appliance is installed. The UMB allows Ceiling•15/30/601751951115/150A 77 for consistent installation and easy replacement of appliances if required. Wall models provide an optional locking screw for extra rat Universal Mounting Base '#' n secure installation, while the ceiling models provide a captivated V Ceiling and Wall Mounts to 5 Backbox Types screw to prevent the screw from falling during installation. +� tel Environmentally Friendly Low Current Draw Compatibility and Requirements -Synchronize using the Wheelock'Sync Modules or panels with built-in Wheelock`Patented Sync Protocol -Compatible with UL"Regulated Voltage"using filtered VDC or unfiltered VRMS input voltage -Strobes produce 1 flash per second over the"Regulated Voltage"range *Compared to competitive models "**Patented **Compared to previous models NOTE:All CAUTIONS and WARNINGS are identified by the symbol A.All warnings are printed in bold capital letters. A WARNING; PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING,SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.COOPERNOTIFICATION.COM OR CONTACT COOPER NOTIFICATION FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS,CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION,WHICH COULD RESULT IN PROPERTY DAMAGE,AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes: General Notes: •Strobes are designed to flash at 1 flash per second minimum over their"Regulated Voltage Range". •All candela rat ngs represent minimum effective strobe intensity based on UL Standard 1971. •Series Exceder Strobe products are Listed under UL Standards 1971 and 464 for indoor use with a temperature range of 32°F to 120°F(0°C to 49°C)and maximum humidity of 93%(±2%)UL 464(85%UL 1971). •Series Exceder horns are under UL Standard 464 for audible signal appliances(Indoor use only). Low Current Draw = Fewer Power Supplies Strobe Ratings per UL Standard 1971 UL Max Current- 24 VDC/24 FWR urrent`24VDC/24FWR I I 12VDC Model Regulated Voltage 15 15/75 30 I 60 1 75 95 110 I 115 I 135 1 150 I 177 I 185 15 15/75 Range VDC I I ST 8.0-33.0 0.057 0.070 0.085 0.135 0.163 0.182 0.205 0.253 0.110 0.140 STC 8.0-33.0 0.061 0.085 0.103 1 0.135 0.163 0.182 0.205 0.253 0.110 Horn Strobe Ratings per UL 1971 &Anechoic at 24VDC UL Max Current'at Anechoic 99 dBA 24 VDC I 12VDC Model Regulated Voltage 15 15/75 30 I 60 I 75 95 110 1 115 1 135 I 150 I 177 1 185 15 15/75 Range VDC I IHS 8.0-33.0 0.082 0.095 0.102 0.148 0.176 0.197 0.242 0.282 0.125 0.159 HSC 8.0-33.0 0.082 0.102 0.141 0.148 0.176 0.197 0.242 0.282 0.125 UL Max Current'at Anechoic 95 dBA 24VDC I 12VDC Model Regulated Voltage 15 15/75 30 1 60 I 75 95 110 1 115 1 135 1150 1 177 1 185 15 15/75 Range VDC I HS 8.0-33.0 0.073 0.083 0.087 0.139 0.163 0.186 0.230 0.272 0.122 0.153 HSC 8.0-33.0 0.073 0.087 0.128 0.139 0.163 0.186 0.230 0.272 0.122 UL Max Current'at Anechoic 90 dBA 24VDC 12VDC Model Regulated Voltage 15 15/75 30 60 75 95 110 115 ` 135 150 177 I 185 15 15/75 Range VDC IHS 8.0-33.0 0.065 0.075 0.084 0.136 0.157 0.184 0.226 0.267 0.120 0.148 HSC 8.0-33.0 0.065 ! 0.084 0.120 10.136 0.157 0.184 0.226 0.267 0.120 Horn Ratings per UL Anechoic Model Regulated Voltage 99 dB 95 dB 90 dB 4Z--- Range VDC IHN 16-33.0 0.064 0.044 0.022 f --.....,,,...... HNC 16-33.0 0.084 0.044 0.022 it - e'�;,� ss. HN 8.0-17.5 0.047 0.026 0.017 ,iP \' / HNC 8.0-17.5 0.047 0.026 0.0171 4l \•.....%. .,.. * UL max current rating is the maximum RMS current within the listed voltage range(16-33 VDC for 24 VDC units). For strobes the UL max current is usually at the minimum listed voltage(16 VDC for 24 VDC units). For audibles the max current is usually at the maximum listed voltage(33 VDC for 24 VDC units). For unfiltered ratings, see installation instructions. Specification & Ordering Information Sync w! Model Strobe DSM or 12/24 VDC* Mounting Candela Wheelock Power Options Supplies Horn Strobes HSR 15/1575/30/75/951110/135/185 X X x UMB*` N HSW 1511575/30/75/95/110/135/185 X X .°n UMB** I To HSRC 1 5/30/60/75/9 511 1 511 5011 7 7 X X p o UMB** HSWC 15/30/60/75/95/115/150/177 X X a) UMB"* 'o Strobesazs 771 a.,E STR .> 15/1575/30/75/95/110/135/185 X X o UMB" Qy 51W41.1 15/1575130/751951110/135/185 X X M UMB** ESTRC — 15/30/60/75/95/115/150/177 X X u= UMB** I w STWC C 15/30/60/75/95/115/150/177 X X a. UMB'* cu Horn r0 c O HNR 0 X X CD UMB** A HNW c rB X X c UMB ** w HNRC X X iv rt3 l) of UMB** HNWC X X UMB** I *12 VDC models feature 15&15/75 settings *"UMB=Universal Mounting Base Model Legend ' HN = Horn = r f �,e- A =Agent LetteringCC. ' ffi fl ST = Strobe (Strobes only) ..-"(� HS = Horn Strobe AL—Alert Lettering 11. �- C =Ceiling Mount (Strobes only) •�,,, W = White N =No Lettering R = Red (Strobes only) . ` el ,` �� t. .,--""'--.."' Example 1: STRC=Strobe,Red,Ceiling Mount N t Example 2: HSR=Horn Strobe,Red,Wall Mount Example 3: HSW=Horn Strobe,White,Wall Mount / i Example 4:51W-AL=Strobe,White,Wall Mount,Alert Lettering Example. Example: HSWC • F ; 1 r 16 ` ' � P, Ji71 iit\, HEN _� li ¶ itFinn" ,1 lir 0 0 ,,, , �., -4±144.11 IMIIIIIIMIIIIIIIIIIIIIIIIIIIIIIIIII III *UMB �``' Contact Cover Voltage test points for quick 8 candela settings Common base for wall and ceiling with 5 troubleshooting and easy spot mounting options checking(wall models only) NOTE: Due to continuous development of our products,specifications and offerings are subject to change without notice in accordance with Cooper Wheelock Inc.,dba Cooper Notification standard terms and conditions. Architects and Engineers Specifications The notification appliances shall be Wheelock` Exceder'"" Series HS Audible Strobe appliances, Series ST Visual Strobe appliances and Series HN Audible appliances or approved equals.The Series HS and ST Strobes shall be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired)for Indoor Fire Protection Service. The Series HS and HN Audibles shall be UL Listed under Standard 464 (Fire Protective Signaling). All Series shall meet the requirements of FCC Part 15 Class B. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel(FACP)with the ability to operate from 8 to 33 VDC. Indoor wall models shall incorporate voltage test points for easy voltage inspection. The Series HS Audible Strobe and ST Strobe appliances shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan®lens. The Series shall be of low current design. Where Multi-Cande#a appliances are specified, the strobe intensity shall have 8 field selectable settings at 15, 15175, 30, 75, 95, 110, 135, 185 candela for wall mount and 15, 30, 60, 75, 95, 115, 150, 177 candela for ceiling mount. The selector switch for selecting the candela shall be tamper resistant The 15/75 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on-axis is required (e.g.ADA compliance). Appliances with candela settings shall show the candela selection in a visible location at all times when installed. The audible shall have a minimum of three(3)field selectable settings for dBA levels and shall have a choice of continuous or temporal (Code 3)audible outputs. The Series HS Audible Strobe, ST Strobe and Series HN Audible shall incorporate a patented Universal Mounting Base that shall allow mounting to a single-gang, double-gang, 4-inch square, 3.5-inch octal, 4-inch octal or 100mm European type back boxes. Two wire appliance wiring shall be capable of directly connecting to the mounting base. Continuity checking of the entire NAC circuit prior to attaching any notification appliances shall be allowed. Product shall come with Contact Cover to protect contact springs. Removal of an appliance shall result in a supervision fault condition by the Fire Alarm Control Panel(FACP). The mounting base shall be the same base among all horn, strobe, horn strobe,wall and ceiling models. All notification appliances shall be backwards compatible The Series HS and ST wall models shall have a low profile measuring 5_24"H x 4.58"W x 2.19" D. Series HN wall shall measure 5.24" H x 4.58"W x 1.6" D. The Series HSC and STC shall been round and have a low profile with a diameter of 6.68" x 2_63" D. Series HNC ceiling shall have a diameter of 6.68"x 1.50" D. When synchronization is required,the appliance shall be compatible with Wheelock®'s DSM Sync Modules,Wheelock®Power Supplies or other manufacturer's panels with built-in Wheelockg Patented Sync Protocol.The strobes shall not drift out of synchronization at any time during operation. If the sync protocol fails to operate,the strobe shall revert to a non-synchronized flash-rate and still maintain (1) flash per second over its Regulated Voltage Range. The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with Wheelock"synchronization protocol. Wall Appliances—UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC, FM Ceiling Appliances—UL Standard 1971, UL Standard 464, California State Fire Marshal(CSFM), ULC, FM NEJVIA I WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Exceder- Spec Sheet 6111 NJ Location 273 Branchport Ave. Long Branch,NJ 07740 P:800-631-2148 F:732-222-8707 www,coopernotification.com , Cooper Notification is Wheelock' SAFEPATH° WAVES, , COOPER Notification 0 LC) 0 0 Cf) 0 row SCOPE OF WORK SITE FIRE ALARM EQUIPMENT SYMBOL LIST o o MODIFY AN EXISTING ADDRESSABLE CENTRAL STATION FIRE ALARM SYSTEM I SYMBOL DESCRIPTION NEW RELOC EXIST PART # ROUGH-IN / NOTE MOUNTING HEIGHT ? oCO WHICH INCLUDES CENTRAL STATION OFF-SITE REPORTING AND 111 CO 0 c:3 ADDING/RELOCATING HORN/STROBES, AND STROBES. S�,O� FACP FIRE ALARM CONTROL PANEL 1 710012D EXISTING EXISTING 7 1�aJF , RyR�HOBO LNAC� FIRE ALARM REMOTE POWER SUPPLY 2 SILENT95 KNIGHT EXISTING EXISTING X 0 p LU LL cr) �9 HORN/STROBE - WHITE WHEELOCK 1 GANG, 2 GANG, 4" SQUARE, 3.5" 80" MIN TO LENS BOTTOM AFFco ° (NAC AND CANDELA NOTED AT DEVICE) 6 3 EXCEDER OCTAL. AND 4" OCTAL. 96" MAX TO TOP OF LENS AFF coCO GENERAL NOTES HSW 6" MIN TOP OF LENS TO CEILING STROBE - WHITE WHEELOCK 80" MIN TO LENS BOTTOM AFF 1 GANG, 2 GANG, 4" SQUARE, 3.5" ° (NAC AND CANDELA NOTED AT DEVICE) 3 EXCEDER OCTAL. AND 4" OCTAL. 96" MAX TO TOP OF LENS AFF 1. THE FIRE ALARM SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH NFPA AST�f 6" MIN TOP OF LENS TO CEILING 72 AND NFPA 70, ARTICLE 760, POWER LIMITED SYSTEMS. CWHEELOCK CEILING MOUNT HORN/STROBE - WHITE 1 GANG, 2 GANG, 4" SQUARE, 3.5"2. FIRE ALARM WIRE INSTALLED IN VERTICAL RUNS AND PENETRATING MORE �01 EXCEDER CEILING MOUNT (NAC AND CANDELA NOTED AT DEVICE) OCTAL. AND 4" OCTAL.THAN ONE FLOOR SHALL BE RISER RATED. HSWC 3. FIRE ALARM WIRE RUN IN DUCTS OR PLENUMS SHALL BE PLENUM RATED. II-41 CEILING MOUNT STROBE - WHITE WHEELOCK 1 GANG, 2 GANG, 4" SQUARE, 3.5" CE4. ONLY SYSTEM WIRING CAN BE RUN IN THE SAME CONDUIT. 1111 III C© (NAC AND CANDELA NOTED AT DEVICE) STWC OCTAL. ANO 4" OCTAL.5. A SYSTEM GROUND MUST BE PROVIDED FOR EARTH DETECTION AND li II o2 EXCEDER CEILING MOUNTLIGHTNING PROTECTION DEVICES. ,Illl�f11l11, il: 6. DEDICATED BRANCH CIRCUITS) AND CONNECTIONS SHALL BE MECHANICALLY 1 II I NOTE: NOTIFfCATION DEVICE COUNT IS FOR FHIS TI ONLYm PROTECTED. 7. CIRCUIT DISCONNECT MEANS SHALL HAVE A RED MARKING, IDENTIFIED AS � %III "FIRE ALARM CIRCUIT". Lu 8. AUDIBLE ALARMS SHALL CONFORM TO SECTION 18.4.4 PUBLIC MODE cr (NFPA 72). NOTIFICATION CIRCUIT SCHEDULE 9. CENTRAL STATION MONITORING SHALL BE DOCUMENTED UPON COMPLETION --It Nil OF THE PROJECT IN ACCORDANCE WITH SECTION 26.6.4 (NFPA 72). z 10. A RECORD OF COMPLETION SHALL BE PROV€DED TO THE FIELD INSPECTOR VOLTAGE DROP CALCULATIONS AT THE ACCEPTANCE TEST INSPECTION IN ACCORDANCE WITH o SECTION 7.5.62 (NFPA 72). CKT DEVICE LOCATION / AREA CIRCUIT TOTAL WIRE WIRE VOLT VOLT ACCEPTED VOLT RE VEEWEDIAPPROVI=D: ORIGIN AMPS DIST SIZE DROP AT EOL DROP DROP % r NO-1 STROBES AND HORN/STROBES EXISTING - MAX ASSUMED FACP 1.500 400 14 3.68 16.72 YES 18.06% 1 N0-2 STROBES AND HORN/STROBES EXISTING - MAX ASSUMED FACP 1.500 400 14 3.68 16.72 YES 18.06% ' - N1-1 STROBES AND HORN/STROBES BANNER BANK - SUITE 300 NAC1 0.994 480 14 2.93 17.47 YES 14.36% N1-2 STROBES AND HORN/STROBES EXISTING - MAX ASSUMED NAC1 1.500 400 14 3.68 16.72 YES 18.06% Ni-3 STROBES AND HORN/STROBES EXISTING - MAX ASSUMED NAC1 1.500 400 14 3.68 16.72 YES 18.06% N1-4 STROBES AND HORN/STROBES EXISTING - MAX ASSUMED NAC1 1.500 450 14 4.14 16.26 YES 20.32% BEN BREIT-4460LEA N2-1 STROBES AND HORN/STROBES BANNER BANK - SUITE 300 NAC2 0.581 400 14 1.43 18.97 YES 6.99% BATTERY CALCULATIONS N2-2 STROBES AND HORN/STROBES HI-TECH - SUITE 305 NAC2 0.819 415 14 2.09 18.31 YES 10.23% F C I-7100 (ELEC) ADDRESS SCHEDULE N2-3 STROBES AND HORN/STROBES EXISTING - MAX ASSUMED NAC2 1.500 400 14 3.68 16.72 YES 18.06% RECEIVED NO CHANGES N2-4 STROBES AND HORN/STROBES EXISTING - MAX ASSUMED NAC2 1.500 400 14 3.68 1 16.72 YES 18.06% PART # DESCRIPTION QTY STANDBY STANDBY TOTAL ALARM ALARM TOTAL END-OF-LINE METHOD OF CALCULATION SEP 3 2019 FCI-7100 MAIN CIRCUIT BOARD 1 0.0650 0.0650 0.0850 0.0850 0 L 1J SLC ALARM MAX SLC ALARM CURRENT 1 0.0000 0.0000 0.4000 0.4000 CITY OF TIGARD NO-1 NOTIFICATION - MAX ASSUMED 1 0.0000 0.0000 1.5000 1.5000 BUILDING DIVISION NO-2 NOTIFICATION - MAX ASSUMED 1 0.0000 0.0000 1.5000 1.5000 RISER DIAGRAM STANDBY TOTAL 0.0650 ALARM TOTAL 3.4850 NO CHANGES *CALCULATIONS BASED ON 24 HR STANDBY TIME & 5 MIN ALARM TIME* AMPS (A) X TIME (H) - AMP-HRS (AH) 20% DEBATE STANDBY 0.0650 X 24 = 1.5600 - Z ALARM 3.4850 X 0.0833 = 0.2904 - TOTAL AH = 1.8504 2.2205 FIRE ALARM OPERATIONAL MATRIX R I X BATTERIES TO BE INSTALLED: 7.0 AH COI SYSTEM OUTPUTS Cle ° aO��P a 'OOa c, W �P� �i�P P� Z a�Q " a- ia ,c0 y G< G ° G4 °e" <c`," , 00 a Q�O 4.9604-45) AFP4° y5 P P S Q �Q44'Q24¢ �0Nos' Joke Q�¢�5 G•• P� �4�aGv�C,,c. c'� ' BATTERY CALCULATIONS SYSTEM INPUTS P P `e a P C NOTES: EXISTING ALARM CONDITIONS • • • • SILENT KNIGHT 5495 #1 (3RD FLR ELEC) EXISTING TROUBLE CONDITIONS • • W EXISTING SUPERVISORY CONDITIONS • • (PART # DESCRIPTION QTY STANDBY STANDBY TOTAL ALARM ALARM TOTAL w 5495 MAIN CIRCUIT BOARD 1 0.0750 0.0750 0.2050 0.2050 LOSS OF AC POWER AT FACP • • Z O I- N1-1 NOTIFICATION 1 0.0000 0.0000 0.9940 0.9940 OPEN CIRCUIT • • W C'') CO1-2 NOTIFICATION - MAX ASSUMED 1 0.0000 0.0000 1.5000 1.5000 DISCONNECTION OF BATTERIES • • 111 C J N1-3 NOTIFICATION - MAX ASSUMED 1 0.0000 0.0000 1.5000 1.5000 GROUND FAULT • • V N1--4 NOTIFICATION - MAX ASSUMED 1 0.0000 0.0000 1.5000 1.5000 STANDBY TOTAL 0.0750 ALARM TOTAL 5.6990 i *CALCULATIONS BASED ON 24 HR STANDBY TIME & 5 MIN ALARM TIME* PRESS SIGNAL SILENCE KEY • • AMPS (A) X TIME (H) = AMP-HRS (AN) 20% DEBATE PRESS RESET KEY • Ce 0 N STANDBY 0.0750 X 24 = 1.8000 - Q C\I ALARM 5.6990 X 0.0833 = 0.4749 - OCK 07 TOTAL AN =1 2.2749 2.7299 11:t BATTERIES TO BE INSTALLED: 7.0 AH = 0 W J OFFICE COPS. o o Q DETAIL 0 Coo W CITY OF TIGARD �/ REVIEWED FOR CODE COMPLIANCE : W cv Q LL Approved ] i U TOP 4 g2 H LL OTC: I ] 0°0 OD 4 CD°� 10*)� 3 Tor _� 11I DWG REV. / DATE Permit #: F- PS��-1`)-00 ) a Ili �_� 4 � 0 09/25/19 Address: -2(caa C 1. ZJI l Y L.i 5ci r d 14Y ;tY BATTERY CALCULATIONS PROMIOU SOURCE ;,, I- TO NEXT DEVICE �+ #� OR OR Suite 1'J•: PREVIOUS DEVICE ^ ;� ^ EOLR �I lel WATCH HASTiNG) NAC SILENT KNIGHT 5495 #2 (3RD FLR ELEC) By: Date: 10-k7--ta NAC IN 1 IIcDUT [TY%Gl ince (!'/RC4,42G) PART # DESCRIPTION QTY STANDBY STANDBY TOTAL ALARM ALARM TOTAL NAC , V'' wu DRAWN BY' 5495 MAIN CIRCUIT BOARD 1 0.0750 0.0750 0.2050 0.2050 I�i'I�a°© 0.a. l I TMB N2-1 NOTIFICATION 1 0.0000 0.0000 0.5810 0.5810 �p C p� N2-2 NOTIFICATION 1 0.0000 0.0000 0.8190 0.8190 lop I , 1 CHECKED BY: N2-3 NOTIFICATION - MAX ASSUMED 1 0.0000 0.0000 1.5000 1.5000 ., - r. BJB N2-4 NOTIFICATION - MAX ASSUMED 1 0.0000 0.0000 1.5000 1.5000 CAUON. PLEASE PROVIDE TON°NTIWERE UNDER STANDBY TOTAL 0.0750 ALARM TOTAL 4.6050 TERMINAL i FILE NAME, BREAK WIRE RUN TO PROVIDE WHEELOCK EXCEDER 'CALCULATIONS BASED ON 24 HR STANDBY TIME & 5 MIN ALARM TIME* SUPERVISION OF CONNECTIONS MOUNTING PLATE FA.dwg AMPS (A) I X TIME (H) = I AMP-HRS (AN) 20% CERATE COMPLETED NFPA 72c !IND MOUNT SIC.HSC STANDBY 0.0750 I X 24 = 1 1.8000 - RECORD OF `I WALL MOUNT ST HS DRAWING#: ALARM 4.6050 X 0.0833 I 0,3837 - COMPLETION AT TOTAL AH =1 2.1837 2.6205 J-� WHEELOCK EXCEDER BATTERIES TO BE INSTALLED: 7.0 AH FINAL INSPECTION 01 NOTIFICATION FA-1 SCALE: NTS ORIGINAL SHEET SIZE'18"x 24" #OF DWGS IN SET: SHEET 1 OF 2 I. 0oo t 0 6 Y0 0 41) co Y co Q I In .'- Nil I- O Q I � L///////:/// 1/ _,.....1 I t ; I I ] I I [.� Willei - " } Fizi - } _. , { I I 115 OFFICE j4EICE OFFICE O101 FICE1 Irai i - '« 1- ____ , OFFICE ' IIIIIII%W IIcz i 111= lin ii�li�l —Ilhi' 1 le 41111 II + I Y 1 . . � li i . .i• I.. . .-`��iii ;Isco MEM • Man T OPEN OFFICE -.-_ , I- IMM u HALL MrA • _, i . - = - OFFICE 8 I 8'_xE I / 8 1 8'X ir . - I C3 6 11391 _— N2-1.1 I I 135CD I I I I I Hilo IIIL'!1 I€lill IIIE:E f fElllElil€€E€III 6EIf1€Y mil f IIEI i 1lEVil{IiEEEE1{IV fE3E{€EIBEE tll !E!i"Hilo Illllill 111111 Y„L ;,,,II,I U„�,Illryif]ill..,i,..liV{I €IEII I ./"./.177 I��':����•I�lil�IliJl 111111(IIII'Y 1ii3ff '•77.1.1 11— 6 1L IV _- — 1 u 2 i c4 i= ilte6i0c a I__ E61,3(8,1_4. IIf� i 11 41 R I S' ! I . . //, ,„• /. ._ __, .. I . ,„,• ,. t 15�D +�'- ,icel l.is ... ! / /J - - 1 ELEC 1.- *: - .� r. I OFFICE13 ■ �/ IP. I I, �� ,� --, 1- — -- �4t N .1rii.,11h4 .440,4 8 litiviil IM, MEI OFFICE I Isco rte ' 7, ' OFFICE OFFICE OFFICE �I OFFICE 9t ? O _-- i� X� I ____ Z I,.. . r_, ,_./° F•41;00 � KM 'I- �r iN �' ® �- III' 1 / I OPEN gFFICE OFFICE - - Pr 0 KM CO w 1 441”. _ ,i4 , ) •� N �'' N� - .__ . - . I�'' I AV � WH �/ .� , /,,/ / _ -_�_ _ ..m it ��� �, 4 n/ \T id / X C; i IN W. 411 AILU . RELOC = •D E I 1— 1111111 0 s_ i' ) -i' I G N1-1.5 I 0 O + /1.0701111.1111 II e • CDNFERENCI` 75cDFr jaw - ! -, _ Ii Ni��a ` - 7 . _- '-- . ;OFFICE _.--__ 1 '1 Mil C� 11 I 1 1 - .. rr.1 ~ ►: CO - �I �!1`-` .._IIII OFFICE O'V 64 OFFICE Elk OFFICE 1 1 _A 3`�, RECEPTION IN/1 I d” lim �J- - _ 1 ___Hi. , --- - 1 411. 11 - ,�� �I 1 x GONFER NCE :, . 1 hi < � — — T — W z xI _ rI�.I u� o &I ==Y ® OPEN OFFICE. OFFICE = AI 1MI -I I r- ql i I_ / UJ m I W �_� til iRELOC Ti �—� / V 011. „ . 4 A -1_4 _ . 41N+ - -- . 0 P 0 .F-__ _ AP-1 .: • N-1,3 • _ -_ill - W 1 A 1 11.i ilj CO ° •- UZD _I ci— D I■ I aril I ` I I 8'x6'{ I • 1 I �� It�3oAzo •�: N1-1.1 I 15GE)E" N!' T — — �. .. I. PY/WOf K 1 I OPEN OFFICE I I =mo` 0 0 N lir Li I ./ il/ - TA-0,„1; . 75CD _ — = I' N -I� I� it I + 75CD • I I z WELCo - __ a LL II1 A. I h �f�1,.' ■„ 1 �' - i�� H-:IIi_ i _ _ —_18YOU'- I _ • 1 - 1+ I + I® li■ill'' W Q 0 7•I M.. I I I I - • , lel iw.l Arr OFF - - il . __. . _.. I -- ., a 1Y 11.1 L. ' .1.. CONFERENCE 15ca CI O 11 N1-1.2FM • a ■ W _ , : . . . _ . „. 1 1 D ie - _ .. ` ct OFFICE _ _ _.1.1 /IA" \ OFFICE OFFICE ® I 1112 12 - L__... _'®� _ 101:1I_ LL - —._.,, + 1--- -- . .-- 'L.. WI DWG REV. / DATE OFFICE OFFICE OFFICE OFFICE OFFICEI + I = - - OFFICE OFFICE OFFICE OFFICE QI. Qui - MI0 09/25/19 FiTel '. CEM X1712M DA T TLJ1 I 1 ,_ I _� .. . I m I I L , •. — I DRAWN BY. TMB PROVIDE NEW CEILING TILE (SAT-1)AT EXISIrING CEILING GRID ( ) EXISTING CEILING GRID AND TILE T REMAIN CHECKED BY BJB FILE NAME: I FA.dwg DRAWING#: 0 0 THIRD F L O O 0 4' 8' 16' _ - FA-2 SCALE: 1/8"=1'--0" ORIGINAL SHEET SIZE 18"x 24" #OF DWGS IN SET: SHEET 2 OF 2