Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans (144)
F PS2O 19-00097 OFFICE COP" }co L1, RECEIVED 85 ° CAFE SUBMITTAL REVIEW JUL 11 2019 14 NO EXCEPTIONS NOTED CITY OF .I IU ►NCJ Z z UtWING DIVISION 0 o No further review of submittal is required. MAKE CORRECTIONS NOTED Incorporate corrections in work: Re submittal is not required. If contractor cannot comply u) reCi- > w CA with corrections as noted, revise to respond to exceptions and resubmit. Record Drawings L1.1 ❑ shall reflect corrections. PLEASE PROVIDE AT REVISE AND RESUBMIT COMPLETED NEPA 72 w Revise as noted, and resubmit for further review. RECORD OF cc COMPLETION AT ❑ NOT REVIEWED: STATE REASON FINAL INSPECTION This submittal has been reviewed only for the limited purpose of checking for general W E conformation with fire design concept as expressed in the contract documents, subject to the ¢o requirements of the contract documents. Nothing in this review is intended to authorize any 4 4 WAS H IN G' 1 '(DN SQUARE aspect of work that is set in accordance with state and local code requirements. SIEMENS BUILDING TECHNOLOGIES, INC. z Youngberg SIGNATURE Garrick o p„o .79.o,� DATE fte 0I 77 mw0 Ywsdm.11M 1 PRINT NAME Garrick Youngberg, SET NICET LEVEL NICET-90549 LEVEL-IV CERTIFICATION NUMBERS LEA-648LEA WASHINGTONSQ. MALL ADDITION PROJECT NUMBER 440P-265383 9585 SW WASHINGTON SQ. ROAD TIGARD, OREGON 97223 OFFICE COPY CITY OF TIGARD In SHEET # SHEET TITLE D FOR CODE COMPLIANCE GENERAL NOTES Approved: a Z THIS FIRE PROTECTION DESIGN IS BASED ON BUILDING CONFIGURATIONS AS OF FA0.00 FIRE ALARM COVER SHEET AND JOB INFORMATION OTC: I IW THE DATE OF THE LATEST REVISION TO THIS DRAWING. Permit#: FID•Sin19 _Ono9 c .Y FA2.00 FIRE ALARM FLOOR PLAN - 85c BAKERY CAFE D02 Address: C17Sa_ ‘„�t_s I,, S cL ed s o , . aZ1 1 . DETECTION DEVICE ADDRESSES ARE INDICATED WITH (6) DIGIT NUMBERS. Suite #: f)- o Q " EI FA9.00 FIRE ALARM DEVICE WIRING/ELEVATION DETAILS By: �+4 Date: -7 _ 1�1- / ! ui 2 e gg 2. MINIMUM WIRE SIZE SHALL BE 16 AWG UNLESS OTHERWISE NOTED. — . " i V hH coo E a z� 22 3. ALL WIRE TO INDICATING DEVICES IS ELECTRICALLY SUPERVISED. PARALLEL a,�+ c l''''° > BRANCHING OF WIRE IS NOT PERMISSIBLE. FIRE ALARM LEGEND 4. ALL WIRE SHALL CONFORM TO NEC LATEST EDITION. FIRE ALARM INDICATING APPLIANCE, AUDIBLE/VISUAL, FIRE ALARM MANUAL PULL STATION, SCOPE o F WORK (SPEAKER/STROBE),WALL MOUNTED BO"AFF. WALL MOUNTED 42"AFF,UON 5. SMOKE DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF FIRE ALARM INDICATING APPLIANCE,VISUAL, SUPPLY AIR DUCTS. ��, (STROBE(,WALL MOUNTED 80"AFF. ICRj CONTROL RELAY MODULE. THIS TENANT IMPROVEMENT PROJECT COVERS ENHANCEMENTS TO THE EXISTING S SINGLE INPUT SIGNAL MODULE. 6. WIRE DESIGNATIONS: TSP = TWISTED SHIELDED PAIR; TP = TWISTED PAIR FIRE ALARM LIFE SAFETY SYSTEM WITHIN THE 85c BAKERY TENANT SPACE LOCATED a FIRE ALARM INDICATING APPLIANCE,AUDIBLE/VISUAL, (NON- SHIELDED); TYPE FPL, FPLP, OR FPLR AS REQUIRED. AT THE WASHINGTON SQUARE MALL IN TIGARD, OREGON. (SPEAKER/STROBE),CEILING MOUNT,P=PENDANT MOUNT. MM SINGLE INPUT MONITOR MODULE. 0, FIRE ALARM INDICATING APPLIANCE,VISUAL, DM DUAL INPUT MONITOR MODULE. NEW FIRE ALARM NOTIFICATION APPLIANCES (STROBE AND SPEAKER/STROBE) ARE P !STROBE),CEILING MOUNT,A_PENDANT MOUNT. BEING ADDED TO PROVIDE NOTIFICATION COVERAGE WITHIN THE TI AREAS. FIRE ALARM PANEL: R RELAY MODULE,NON-ADDRESSABLE FACP;FIRE ALARM CONTROL PANEL, pp WATERFLOw SWITCH THE STROBE AND SPEAKER CIRCUIT WILL BE CONNECTED TO AN NEW POWER FAAP;FIRE ALARM REMOTE ANNUNCIATOR PANEL, 0 SUPPLY LOCATED IN SECTOR C AND EXISTING AUDIO BOOSTER VIA A JUNCTION BOX FAPS;FIRE ALARM BOOSTER POWER SUPPLY, q_ lya TAMPER SWITCH LOCATED AT THE REAR OF THE SPACE. FATC;FIRE ALARM TERMINAL CABINET. 001 -020 FAFS;FIRE ALARM FIRE SUBSCRIBER RADIO PANEL. Ct PIV SWITCH FANP,FIRE ALARM NETWORK PANEL. ANALOG LOOP# J NNDEVICE NUMBER 0 ANALOG ADDRESSABLE SMOKE DETECTOR PRESSURE SWITCH 10K -w- END OF LINE RESISTOR,10K Ohm SHOWN. O ANALOG ADDRESSABLE HEAT DETECTOR, ilip REMOTE ALARM LED,CEILING MOUNT QQ R "R"RATE-OF-RISE,"F"l]S DEGREE FIXED. FSD FIRE/SMOKE DAMPER J O N1 -5 S P-5 0 ANALOG ADDRESSABLE DUET DETECTOR (;) DOORHOLDER(BY OTHERI STROBE CIRCUIT 1DEVICE NUMBER SPEAKER CIRCUIT C'RCUIT NUMBER R "R"-RELAY BASE Q W I- POWER SUPPLY# OUTPUT NUMBER LEO$ REMOTE LED AND TEST SWITCH W a.gz VALIDITY OF PE :; Q cn THE ISSUANCE OF A PERM W Q BASED ON CONSTRUCTiOi 0 O Li_ Q — DOCUMENTS AND Cly U' OTHERU DATA SHALL NOT PREVENT Z Z Q FIRE ALARM WIRE LEGEND THE CODE OFFICIAL FRC,;,,; 0 = 0 CC a REQUIRING THE CORHECTJON1 I__ CO W LU Q A. ANALOG DATA LOOP - ONE PAIR #16 AWG UL LISTED TWISTED PAIR RED JACKETED OR ERRORs. OSSC 1 n� (� Q r Iii TYPE FPL POWER LIMITED CABLE Z O CO o = p ,0 B. STROBE NAC CIRCUIT - ONE PAIR #14 AWG UL LISTED TP (TWISTED PAIR) RED JACKETED up EL co TYPE FPL POWER LIMITED CABLE on o 0KEY PLAN < d (Ls)) D C. SPEAKER NAC CIRCUIT - ONE PAIR #16 AWG UL LISTED TSP (TWISTED SHIELDED PAIR) ENGINEER: ., RED JACKETED TYPE FPL POWER LIMITED CABLE � Fr--_ G.YOUNGBERG V. 120 VAC POWER - 3 CONDUCTORS #12 AWG THHN WIRE SCALE: ' FIRE ALARM CIRCUITS CLASSIFICATION: NONE i CLASS-B:`-f-, L____ DATE: (A) DATA LOOP, (S) SPEAKER NAC (NOTIFICATION APPLIANCE CIRCUIT, (V) STROBE 07.10.2019 NAC (NOTIFICATION APPLIANCE CIRCUIT), (E) 120 VAC DEDICATED POWER CIRCUIT 2 NOTES: _i L ro 1. FOR RISER RUNS, USE TYPE FPLR RISER DESIGNATED CABLE. 7 r[ 1 ----- E 2. FOR PLENUM RUNS, USE TYPE FPLP PLENUM DESIGNATED CABLE. CHECKED BY: I G. YOUNGBERG ILL FIRE ALARM .6. COVER SHEET 11Z B AND al JOB INFORMATION tn az y FA0 . 00 0. .. 9 x Sheet Size', 24"x35"=1:1 Stale THIS DRAWING AND DESIGNS THEREON SHALL NOT BE DUPLICATED,USED OR DISCLOSED TO OTHERS FOR PROCUREMENT OR OTHER PURPOSES,EXCEPT AS OTHERWISE AUTHORIZED BY CONTRACT,WITHOUT EXPRESS WRITTEN CONSENT DE SIEMENS BLUING TECHNOLDEIES A DIVISION OF SIEMENS INDUSTRY INC.ALL REPRODUCTIONS SMALL BEAR TH!5 NOTICE N m c%f FIRE ALARM SHEET NOTES: • 1. DEMO ALL EXISTING SMOKE DETECTORS IN SPACE. 2. EXTEND STROBE CIRCUIT FROM EXISTING JBDX LOCATED BEHIND SPACE. EOL TO REMAIN AT JBDX, PULL CABLE FROM LAST STROBE DEVICE BACK TO JBOX. • 3. EXTEND SPEAKER CIRCUIT FROM EXISTING JBDX LOCATED BEHIND SPACE. EOL TO REMAIN AT JBOX, PULL Z ❑ L CABLE FROM LAST SPEAKER DEVICE BACK TO JBDX. O O • / 4. ALL FIRE ALARM SYSTEM WIRING MUST BE INSTALLED IN METAL CONDUIT, AND ALL CONDUIT, JUNCTION BOXES, CL / AND ENCLOSURES MUST BE PAINTED RED AND LABELED FIRE ALARM TC11O1FAPSTO cn 75cd NC1 - W MN 001.045 W/F 5. OVERALL SITE COORDINATION REQUIRED WITH ALL OTHER TRADES, SIEMENS' FIELD TECHNICIAN AS WELL AS SIM 001.046 W/F I 1/2 W OWNER'S DESIGNATED REPRESENTATIVE FOR FIRE ALARM/LIFE SAFETY SYSTEM 'ALLISON BYKOWSKI'. 1 ❑ I. 6. EXHAUST HOOD MONITOR MODULE. 7 Lo cc _ 1. CONTROL RELAY TO SHUT DOWN AIR HANDLER. o SCOPE OF -_ AI - - ce ce LJ � Ll— s I w 0 �' 1-1 8. COORDINATE DUCT DETECTOR INSTALL ON NEWLY PROVIDED AIR HANDLER WITH MECHANICAL CONTRACTOR. v, �. ' w .II ,5cd _ WORK ' I I 0001 ' 9• • . INTERCEPT AUDIO CIRCUIT FROM J-BOX LOCATED IN SERVICE CORRIDOR IN C10. w o /r. Z.7 i.- FAPS-C1 a NC1-1- �� 10. ROUTE NC1-1 TO FAPS-C1 LOCATED IN RISER ROOM IN SECTOR C. a .4 30cd r ill i2 TBD I i ; i 11. INSTALL NEW FAPS IN RISER ROOM IN SECTOR C, PROVIDE MONITOR MODULE TO MONITOR POWER SUPPLY. FAPS-C1 TRB� I r 1 � . 1/2 W J --•a�l�-ala Ilw F j I 1 /4K 12. CONTROL RELAY, DUCT DETECTOR, DEVICES ON BAKERY ROOF. Z — / 1FOL Cl-1 NC1-1-13 13. INSTALL NEW SLC CABLE FROM NEW BAKERY DEVICES_ _ Ncld ' ❑ ❑ a I = •. ,ems _ ❑ F 1 I 1 [-] 1 _1 . ,_ 1 • ! I 1 ] �f30c1d-1-a • 15cd 2 -:L'' 0441 � NC11-11Y I1/2 W I, 1/2 W i • `c!..H r its O ' I )ci 102 ANEW STOCK ROOM ! o nay-Dt I ❑; '--i 1 g T r I n, ,�,r,, L.BOX ___- VI 1 i i A `� 1 — a 75cd -, I 7,.____-------'____/ TBD _ 04 2W �j ,..,., Ii I: ill / I —� —1 1I �' 3 Z j I _, 1 / NC1-1 oS - E I I 3acd -7E. I I • SCOPE OF • W W SCOPE OF � � WORK I `__ _ . - I DLER ....v,6* 0: Jr.; go L Y co as / _ 1 NC1-1-10 y 8s I I �__0 3acd ' I I _ �� 1/2 W m �w. 1 -`x I in c 1. I , . I '1' Ie.. c ,..,. 1i !1 : I . I 1 _ .,,. NC1-1-09• O 15cd I .-_ . _ _ I NC1 1 06 Q� 3Ocd _ III. '. 1/2 w cR I 11 I l: I• � — '4 — — .• iu. 11 11� I 1 I } HODD MC b-:- _ I i,... •. ........_. = I -_ EE iii .. 1 _ _ „ „ _ , ,i_ _ 1 :,• 1 : . ON MUA MON1 I 102.25 102.26 �c 11d-1CR CR I �� 07 f 1 1/2 w = I 102.008 �® 102.27 102.28 N��d 1-a8= 21 P -TEP. -- © -1 I = ci 1 01/8 w _ I 4® ♦ `_I Qw TYP. mumI Q / W3 ICtG I I it I� • LLI SCOPE OF `� " z 102.009 Z ? 0 >- ®P . OOu) w w WORK Ohoa Z CO 0 l- Cl) Ie o co - Qci.000 N C7 Lig t~ 0 3 o im 3m ENGINEER: ., , n n 0 G.YOUNGBERG o a SCALE: I.A 1/8 = 1'-(T DATE: IQ ' = 07.10.2019 1-= i � iL 0, 13 A E CHECKED BY: G. YOUNGBERG iz FIRE ALARM FLOOR PLAN - ot 85° BAKERY CAFE FIRE ALARM PLAN PROJECT LAYOUT TI SCALE: 1/8"=1 ' o" 1W 1 ,-; 0 4' 8' 16' 1 . FA2 . 00 1� i_ ,m frc- Sheet Size: 24"x36'=k1 Scale TFIS DRAWNG AND RESIGNS TIREON SHALL NOT BE DUPLICATED,USED 014DISCLOSED TO DTI-HS FOR PROUIRDENT OR OTHER PURPOSES,EXCEPT AS OTHERWISE AU THORIZED BY CONTRACT.WITFIOUT EXPRESS WRITTEN CONSENT OF SIEMENS BUILI M TECHNOLCUES.A DIVISION OF SIEMENS INDUSTRY INC.ALL REPRO k TIONS SHALL BEAR?HS } L.,' LCI Z Oo DETAIL NOTES 1- PROVIDE�ICCESS TD DUCT DETECTORS IN ACCORDANCE TD NFPA 90A. 0 2. THE OPERABLE PART OF MANUAL PULL STATION SHALL BE NOT LESS THAN 42"AND NOT MORE THAN 4B"ABOVE FINISHED FLOOR LEVEL PER NFPA-72. r W 3 VERIFY PANEL LOCATIONS PRIOR TO INSTALLATION. 4. WALL MOUNTED VISUAL NOTIFICATION APPLIANCES SHALL BE MOUNTED SUCH THAT THE ENTIRE LENS IS NOT LESS THAN 80"AND NOT GREATER THAN 96"ABOVE FINISHED FLOOR AUDIBLE ONLY WALL MOUNTED NOTIFICATION APPLIANCES SHALL BE MOUNTED AT SAME HEIGHT AS VISUAL NOTIFICATION APPLIANCES. Ct • 5. WHERE LOW CEILING HEIGHTS DO NOT PERMIT MOUNTING A MINIMUM OF BO" WALL MOUNTED NOTIFICATION APPLIANCES SHALL BE MOUNTED 6"BELOW CEILING. ABOVE CEILING DETECTION 5 12"MAX HEAT W 0 _ a DETECTOR ONLY Q \ \ AIRFLOW I I ) IILia P1 I4"MIN HEAT / I �' 5 6"MIN 7 DETECTOR ONLY DUCT DETECTION O CEILINGW o 1. PANEL LABELSiffl......4_4"MIN HEAT o FACP FIRE ALARM CONTROL PANEL FATC FIRE ALARM TERMINAL CABINET DETECTOR ONLY FAAP FIRE ALARM ANNUNCIATION PANEL FACD FIRE ALARM COM PANEL-DIALER141. 1 FABC FIRE ALARM BATTERY CABINET FACR FIRE ALARM COM PANEL-RADIO 70, FADC FIRE ALARM DOCUMENT CABINET FACW FIRE ALARM COM PANEL-WIRELESS I SPEAKER STROBE O FADS FIRE ALARM POWER SUPPLY I STROBE Z 2 + — FACW FACP FAPS FATC FAAP OC! 00 z 1 FAPS 1 80"-96" Q j — - — 72" 60" j STROBE CKT + �4 + TO NEXT STROBE OR END OF UNE 2.2K 1 42" :FABC' + + SEPAKER CKT TO NEXT SPEAKER OR — - _ END OF LINE 24K i R 1 TYPICAL 40 EQUIPMENT MOUNTING ELEVATIONS SCALE NONE SPEAKER/STROBE - WIRING DETAILS SCALE: NONEVil 0z W 2VC II ,,, EI `- - C a=+ -! �� Po gP u ra N. iu FA 0 in � z� E 61 r= ry i v'1 c ELL I 1 Q r QW Q ,s w � 0 I� < � i-z W i r- 14 O U- CO z U Z -O >- O = 0 CC COw w 1 O Z m — moo Hat zo .cc Qoco �OCf) it ¢ CV a In _� O a c,) ENGINEER: •.a a G.YOUNGBERG int SCALE: NONE DATE: 0 07.10.2019 12 t Ito IE CHECKED BY: G. YOUNGBERG 1� FIRE ALARM DEVICE I t 1-o WIRING DETAILS/ MOUNTING I.- ELEVATIONS Ir _E C et, I� ,... W FA9 . 00 c Sheet Size: 24'x36' 1:1 Scafe THIS DRAWING AND DESIGNS THEREON SHALL NOT BE DUPLICATED,USE)OR DISCLOSED TO OTHERS FOR PROCUREMENT OR OTHER PURPOSES.EXCEPT AS OTHERWISE AUTHORIZED BY CONTRACT, TECHNOLOGIES, E #S VLTINC_ I