Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans (145)
F PS2O 19-00046 OFFICE COPY CUSTOMER NAME: RECEIVED OEG APR 1 2019 RovER CCITY OF TIGARD JAGUAR LAND r 1709 SE 3rd Ave BUILDING DIVISION 010-, Portland, OR 97214 POR' I ' LAND , Co ' r;air flt ir TEC - • • ES T E C , r E S/ 7678 SW Mohawk St,Tualatin, OR 97062 Phone: 503-228-8522 Fax: 503-228-8521 This document and the information/depictions contained/shown is the exclusive property of Convergint Technologies LLC and shall be handled as proprietary and confidential information and must be returned upon request. This document cannot be reproduced by any means without the written authorization of Convergint Technologies LLC. OFFICE COPS CrrY OF TIGARD REVIEWED FOR CODE COMPLIANCE Approved: l OTC: ( I Permit s ,PS,AO19w0OO 4 ED Address: ) 1n/�1N j 0-a•, S r r A Ire arm sem : S1uIte#: �- . a B • .... Date. �} J [, - New Installation ���, TL.acmox SYMBOL LEGEND GENERAL NOTES DESIGN INTENT DEVICE LABEL SCHEME DRAWING INDEX . PLEASE PROVIDE 1. 1/1311Ff 2. �6 MME.ROT ALL D A N WY 9E 11WELlii IN TEE FRoAcT. COMPLETED NFPA 72 SYMBOL2 DESCRIPTION MODEL # BACK BOX / DIMENSIONSI 1. ALL WIRE AND CONDUIT MUST BE INSTALLED IN ACCORDANCE WITH PLANS AND SPECIFICATIONS. BUILDING CONSTRUCTION CONDITIONS: SIGNALING LINE CIRCUIT DEVICES: Drawing Number Drawing Title RECORD OF MULTI-CANDELA STROBE G1F-VM SINGLE-GANG, 2-1 8" DEEP BY E.C. • OCCUPANCY B, S-1, S-2 ® / 2. ALL WIRE AND CABLE MUST BE RATED FOR FIRE ALARM USE PER THE LATEST REVISIONS OF THE NATIONAL ELECTRICAL CODE SECTION • LOW-RISE YY XX - ZZZZ COMPLETION AT •xx:CANDE7J�RATING XX •wur Moura MESS OTMERMISE ININATm GCF VM (CEILING) 4-SQ, 2-1/8" DEEP BY E.C. 760. THIS IS A POWER LIMITED FIRE ALARM SYSTEM, ALL CABLE MUST BE MARKED FPL, FPLR, OR FPLP. • FULLY SPRINKLED T T FA0.1 FIRE ALARM COVER SHEET FINAL INSPECTION •C.CUM MCUNT CS405-7A-T (WEATHERPROOF, 15CD) 4-SO W/ WFP-W MOUNTING PLATE • HORN/STROBE NOTIFICATION I DEVICE NUMBER •wP:WEATHERPROOF 3. ALL CONDUCTORS MUST TEST FREE OF GROUND BEFORE MAKING CONNECTION TO THE FIRE ALARM CONTROL PANEL. • GENERAL ALARM EVACUATION LOOP NUMBER FA1.1 A FIRST FLOOR FIRE ALARM PLAN - SOUTH alXX MULTI- o RCANATING LA HORN/STROBE G1F-HDVM SINGLE-GANG, 2-1/8" DEEP BY E.C. 4. TO RETAIN WARRANTY, THE FIRE ALARM EQUIPMENT MUST BE POWERED UP UNDER THE DIRECTION OF A QUALIFIED MANUFACTURERS PANEL NUMBER (IF NETWORK SYSTEM) ,,Y,u MOUNTUNLESS on�ERwsEINDfAFD GCF-HDVM (CEILING) 4-SO, 2-1/8" DEEP BY E.C. OREGON STRUCTURAL SPECIALTY CODE: 2014 ED. FA1.1 B FIRST FLOOR FIRE ALARM PLAN - CENTER •C:CEIUNO MOUNT WG4WF-HVMC (WEATHERPROOF) 4-SQ W/ WFP-W MOUNTING PLATE TECHNICIAN. OREGON FIRE CODE: 2014 ED. HORN & STROBE NOTIFICATION DEVICES: •WP wEATHERPROOF OREGON MECHANICAL CODE: 2014 ED. FA1.1C FIRST FLOOR FIRE ALARM PLAN - NORTH 10 ADDRESSABLE PHOTOELECTRIC SIGH-PD 3-OCT, 1-1/2" DEEP & 3" MUD RING 5. THE LIFE SAFETY SYSTEM I5 A COMPLETELY SUPERVISED SYSTEM ARE ALARM & SIGNALING CODE, NEPA 72: 2013 ED. BPSx - 01 SMOKE DETECTOR SIGA-SB (STANDARD BASE) BY E.C. T FA1.1 M MEZZANINE FLOOR FIRE ALARM PLAN CD •U:IN-DUCT WOouc 6. INSTALLING CONTRACTOR SHALL COORDINATE ALL FIELD CHANGES WITH CONVERGINT TECHNOLOGIES INCLUDING, BUT NOT LIMITED TO, •UF.MNOUNiED III U DEW141 CEUMG. TAFLWRL ACE CHANGES IN DEVICES, WIR ,UNDOCUMENTED CHANGES,EOR THE RESUTLTS CAUSED BYY ON IN THE SsITHOSE CHANGIES.EM. CONVERGNT TECHNOLOGIES SHALL NOT BE HELD RESPONSIBLE FOR NUMBER 24VDCCIRCUITCIRCUIT IDENTIFIER FA1.2A SECOND FLOOR FIRE ALARM PLAN - SOUTH OADDRESSABLE PHOTOELECTRIC SIGA-SO SELF-CONTAINED 7, PUBLIC MODE LIFE SAFETY AUDIBLE TONES SHALL BE AUDIBLE THROUGHOUT THE SPACE AND SHALL HAVE A SOUND PRESSURE LEVEL ABBREVIATIONS LEGEND (E.G. FACP OR BOOSTER POWER SUPPLY) FA1.2B SECOND FLOOR FIRE ALARM PLAN - CENTER L- DUCT SMOKE DETECTOR NOT LESS THAN 15db ABOVE AMBIENT NOISE LEVEL MEASURED 10'-0" FROM THE DEVICE & 5'-0" ABOVE FINISHED FLOOR. FA1.2C SECOND FLOOR FIRE ALARM PLAN - NORTH rE O •PATE ADDRESSABLE i3N- A DETECTORAL APPIJCATIoNs SIGA-HRD 3-OCT, 1-1/2" DEEP & 3" MUD RING B. SYSTEM SHALL BE CLASS "B" IN CONFIGURATION. ARE ALARM DEVICE ABBREVIATIONS: RR SIGA-SB (STANDARD BASE) BY E.C. AC ABOVE CEILING FA1.3A THIRD FLOOR FIRE ALARM PLAN - SOUTH z9. LOCATE ALL PULL STATIONS AND AUDIO/VISUAL UNITS AT SPECIFIED HEIGHTS PER NEPA 72 AND ADA. SEE MOUNTING HEIGHTS DETAIL C = CEILING MOUNTED FA1.3B THIRD FLOOR FIRE ALARM PLAN CENTER O ADDRESSABLE THERMAL DETECTOR SIGA-H2D 3-OCT, 1-1/2" DEEP & 3" MUD RING" ON SHEET FA3.3. E - EXISTING TO REMAIN a F •FIXED TEMPERATURE.usE FOR ELEVATOR SHUNT TRIP SIGA-SB (STANDARD BASE) BY E.C. R - EXISTING TO RELOCATE 10. SMOKE DETECTOR LOCATIONS ARE FOR REFERENCE ONLY AND SHALL BE INSTALLED PER NEPA 72. N .- NEW DEVICE FALK THIRD FLOOR FIRE ALARM PLAN - NORTH z T❑ ADDRESSABLE MANUAL PULL STATION SIGA-270 SINGLE-GANG, 2-1/2" DEEP BY E.C. WP = WEATTHERPROOF ICE FA2.1 FIRE ALARM RISER DIAGRAM /711. SMOKE DETECTORS ON CEILINGS MUST BE NO MORE THAN 15' FROM A WALL AND/OR NO MORE THAN 30' FROM EACH OTHER. EXCEPT wOF = UNDERFLOOR LL IN NARROW CORRIDORS OR IRREGULAR SPACES. FA3.1 FIRE ALARM CONTROL PANEL WIRING DETAIL & BATTERY CALCULATIONS cD S© ADDRESSABLE SIGNAL MODULE er/ SYNC SIGA-CC1S DOUBLE-GANG, 2-1/2" DEEP BY E.C. ARE ALARM GENERAL ABBREVIATIONS: ��]� z SIGA-MCC1S MOUNTED IN MFC/A ON SIGA-U106(R) 12. ALL FIRE ALARM DEVICES SHALL BE RIGIDLY AND SECURELY FASTENED TO WALLS OR CEILINGS. AFF = ABOVE FINISHED FLOOR VY IRE CODE FA3.2 BOOSTER POWER SUPPLY DETAILS & VOLTAGE DROP CALCULATIONS w © ADDRESSABLE DUAL INPUT MODULE SIGA-CT2 SINGLE-GANG, 2-1/2" DEEP BY E.C. 13. NO SMOKE DETECTOR OR HEAT DETECTOR SHALL BE LOCATED CLOSER THAN 36" TO ANY AIR REGISTER, DIFFUSER, FLUORESCENT LIGHT AHJ = AUTHORITY HAVING JURISDICTION o A ON SIGA-Ul06(R)SIGA-MCT2 MOUNTED IN MFC OR CEILING FAN BLAI}E. ALM = ALARM ALL WIRING AND INSTALLATION METHODS SHALL BE IN COMPLIANCE FA3.3 TYPICAL WIRING OF FIRE ALARM FIELD DEVICES Ly / BMS =BUILDING MANAGEMENT SYSTEM WITH CURRENT RELEVENT NATIONAL ELECTRICAL CODE ARTICLES p © ADDRESSABLE CONTROL RELAY: HIGH VOLTAGE SIGA-CRH 4-SO, 2-1/8" BY E.C. EOL = END OF LINE FA3.4 SPECIAL FIRE ALARM FUNCTIONS DETAILS 527 LEA 14. NO HEAT DETECTOR SHALL BE LOCATED CLOSER THAN 36" TO ANY PART OF ANY HEAT GENERATING DEVICE (FUSES, BOILERS. WATER E.C. = ELECTRICAL CONTRACTOR AND RELATED SECTION CODE REQUIREMENTS. a HEATERS, ETC.) HR = HOMERUN WIRING INSTALLATION NOTES: cc ® ADDRESSABLE CONTROL RELAY: LOW VOLTAGE SIGA-CR SINGLE-GANG, 2-1/2" DEEP BY E.C. MAX = MAXIMUM LABEL ALL TONE WIRES WITH ZONE NUMBER TAG AND RON PULIOFF Q SIGA--MCR MOUNTED IN MFC/A ON SIGA-UI06(R) 15. HEAT DETECTORS ACCOMPANYING ELEVATOR SPRINKLER HEADS SHALL BE MOUNTED WITHIN 24" OF ASSOCIATED HEAD. ONE DETECTOR MIN = MINIMUM • PER HEAD. N/A - NOT APPLICABLE • tDAEBERIAALLOSIGNAL CIRCUIT WIRES WITH SIGNAL CIRCUIT ANN FIRE ALARM ANNUNCIATOR RLCD-C SEE DETAIL SHEET NAC - NOTIFICATION APPLIANCE CIRCUIT NUMBER TAG AND DESCRIPTION. - 16. INITIATING AND SIGNALING CIRCUITS ARE SEPARATE YET MAY BE RUN IN SAME CONDUIT/RACEWAY/RISER IF ALLOWED BY NEC. NIC = NOT IN CONTRACT • LABEL ALL NETWORK, ANNUNCIATOR AND I/O CONTROL CIRCUIT a FACP FIRE ALARM CONTROL PANEL 1064 SEE DETAIL SHEET NTS = NOT TO SCALE WIRING WITH CIRCUIT NUMBER TAG AND DESCRIPTION. 0 17. ALL CONDUCTORS SHALL BE LABELED BY CIRCUIT/ZONE AND ALL COLOR CODES SHALL MATCH. SLC - SIGNALING LINE CIRCUIT • ALL WIRING BETWEEN BUILDINGS SHALL BE RATED FOR z BATT FACP BATTERY CABINET BC-1 14"H x 18.25"W x 7.25"D SUP =SUPERVISORY UNDERGROUND USE. Uz 18. THESE DRAWINGS DO NOT SUPERSEDE THE CONTRACT DRAWINGS AND SPECIFICATIONS, THEY ARE INTENDED AS A SUPPLEMENT ONLY TRB = TROUBLE 1 AND MUST BE USED IN CONJUNCTION WITH THE CONTRACT DOCUMENTS. THEY DO NOT MODIFY THE CONTRACTORS OBLIGATIONS TO TYP = TYPICAL LEITER TYPE USE o BPS BOOSTER POWER SUPPLY BPS1 OA 17"H x 13"W x 3.5"D CONFORM TO THE PROJECTS ORIGINAL DESIGN CRITERIA- LION =UNLESS OTHERWISE NOTED WIRE SCHEDULE j A 1 PAIR 16 AWG. TWISTED FPLP DATA LOOP NETWORK r m TG7 CELLULAR COMMUNICATOR TG7LAF02 7.5"H x 11.5"W x 3.5"D 19. ALL WORK SHOWN SHALL COMPLY WITH ALL NATIONAL, STATE AND LOCAL CODES, ORDINANCES, ETC. B 2 PAIR 20 AWG. RS-232 LT_ - ---- --.-.-.- LETTER TYPE USE ado 20. CONVERGIN7 TECHNOLOGIES STRONGLY RECOMMENDS AGAINST THE USE OF STAPLES TO SECURE LIFE SAFETY CABLES. C 1 PAIR 14 AWG. TWISTED FPLP STROBE CKT / 24VDC A 1 PAIR i6 AWG- TWISTED FPLP DATA LOOP NETWORK FDB / DSB FACP DOCUMENTS/DRAWING BOX FAD/OSB FAD: 13"H x 12"W x 2.25"D - - - - - LOOP/ NETWORK 37"H x 5.5"W x 4,25"D E 1 PAIR 16 AWG. TWISTED FPLP AUDIO CKT 21. PER NEPA 72 17.7.1.11.3, ALL SMOKE & HEAT DETECTORS NOT REQUIRED FOR CONSTRUCTION SHALL BE INSTALLED AFTER ALL OTHER --- -- - B 2 PAIR 20 AWG. RS-232 c FLOW/TAMPER/PTV SWITCH BY OTHERS TRADES HAVE COMPLETED THEIR CLEANUP PROTOCOLS. WHERE DETECTORS ARE ALREADY INSTALLED, THEY SHALL BE PROTECTED FROM -.. C 1 PAIR 14 AWG. TWISTED FPLP BPS CKT/24VDC L' DUST, DIRT & DEBRIS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. o 0 - SMOKE DAMPER or FIRE/SMOKE DAMPER BY OTHERS E 1 PAIR 16 AWG. TWISTED FPLP AUDIO CKT EL FIRE ALARM FUNCTIONAL MATRIX rn SEE FA0.1 FOR WIRE SCHEDULE NOTES & GUIDELINES. co o SYSTEM RESPONSE REVISIONS d Pc3 °,c o G°,FP °o°� °L �o� `oc °•*°c pG'`°� REV DESCRIPTION DATE APPROVED i ` ° D c 1 OEG REVIEW 03/20/19 R. PULIOFF Ce .oc i�° Goc Pc °cL c c ti° e P Q-e c 1 1 G°ca G.' a- Coca e °6 �8- ao C \�° �c°� �5p� a°�°c `�-16 Oar° °��pce�r{°Jos o°c Qe�ca�e �c° �.ac° �Rc�� ,e �4�e °�e,<` ' �6' \5\ Er G°�e�°�� e�°� e��Q° °�� o°p�� Qe�\ P°ate -gyp P;enc ry;:Xe' Oa 3ctP o �° e� c FQ P •�� 5v z 4 m ° e o Cl 1NTRATTONDEVICEACNVATE[] PSC VSa Pec Psa Pec\°o Sec Se'E cDe' P4' 4,'' `ci �-' c' °'' P F DRAWN BY: D. SQUIRES Manual Pull Station • • • PROJECT ENGINEER: B. DUFFEL o Smoke Detector • • • Heat Detector • • • c) PROJECT MANAGER: R. PUL!OFF o Duct Detector • • JOB NUMBER: 302-FN-H0441 LLJ SHOP DRAWING SUBMITTAL DATE: 01/25/2019 cc First Floor Elevator Lobby Smoke Detector • • • • CONTRACT TYPE: PLANS 8, SPEC:n DESIGN BUILD: ■ All Other Floor Elevator Lobby Smoke Detectors • • • • Machine Room Heat Detector • • • • PROJECT NAME: Machine Room Smoke Detector • • • • Elevator Pit Heat Detector • • • • - Elevator AC Loss • • _ JAGUAR LAND ROVER Waterflow Swit:h • • • • 10125 SW Washington Sq. Rd. Tamper Portland, OR 97223 4 Systemm Trouble • • SCOPE STATEMENT MATRIX NOTES: VALIDITY OF FLA-, THE ISSUANCE OF A PER/A,i" 6' A. NOT USED. o FIRE ALARM SYSTEM DESIGN PROPOSED PROVIDES FOR A NEW FIRE ALARM CONTROL PANEL, CELLULAR COMMUNICATOR & BOOSTER POWER BASED ON CONSTRUCTIONSHEET NAME: co ▪ SUPPLIES. DOCUMENTS AND OTHER � THROUGHOUT THE B OCCUPANCY PORTION OF THE FACILITY, STROBES & HORN/STROBE DEVICES SHALL BE INSTALLED TO PROVIDE OCCUPANT DATA SHALL NOT PREVENT r;; NOTIFICATION. BOOSTER POWER SUPPLIES WILL PROVIDE 24VDC TO THE NOTIFICATION CIRCUITS. THE CODE OFFICIAL FROM In THE 5-2 & 5-2 PORTIONS OF THE FACILITY ARE NOT INTENDED TO RECEIVE OCCUPANY NOTIFICATION, PER OSSC REQUIREMENTS. REQUIRING THE CORRECTION FIRE ALARM COVER SHEET O 0 OF ERRORS. OSSC 105.4 OFF-SITE COMMUNICATIONS SHALL BE PROVIDED FOR VIA CELLULAR COMMUNICATOR. - ALL AUTOMATIC FIRE DETECTION IS DESIGNED AS CODE MINIMUM. ROOFTOP ELEVATOR OPEN ON TO UNCOVERED VEHICLE PARKING AREA. NO AUTOMATIC FRE DETECTION IS PROVIDED FOR THESE LOCATIONS. AT TIME OF FIRE ALARM SYSTEM DESIGN, MECHANICAL, ELECTRICAL & SPRINKLER SYSTEM DESIGNS WERE NOT YET COMPLETE. AT TIME OF THEIR ISSUANCE FOR CONSTRUCTION, FIRE ALARM SYSTEM SHALL BE REVISED TO INCORPORATE MEP FUNCTIONS AFFECTING LIFE SAI-EIY PERFORMANCE. DRAWING: In In m 5 o FAO . 1 1,,,,z c In cc 0 In In Li,cc J CUSTOMER NAME: OEG 1709 SE 3rd Ave M ) 1 P CI' Portland, OR 97214 \ 1 CoiijJnt Q a I I I I ' LL I L._ li I � � J TEC - • • ES E U I V r� ��p�qq�� II h wk St Tualatin OR 97062 144'4.6.4."11M11111111 ,.rc;n�.•`�![� i 11 I I I l I i ! i I ! ! !T ' I ! III I—� _ '— I TivnY K - Y 0 r,,,,;,,,1, _1T�.._ .,.r y �, :! — - - - Phone: 503-228-8522 Fax 503-228-8521 a III = _ — _ - o - - ;' I - - - - - - 3 ® This document and the information/depictions contained/shown HR TOA - FACP ;�. I - � ° p is the exclusive property of Convergint Technologies LLC and L� 1 n. d ..„ 'i • shall be handled as proprietary and confidential information and -' I I I I _ must be returned u on re nest. This document cannot be 1' nVI '. - _ _ - I I - �- - - - reproduced by any means without the written authorization of 1 � 1 - I I , ti _. -I - - - — T - 19 Convergint Technologies LLC. --- - I I girl~I - ,��,�,�':,� i l ., r. /RVI - 1 I _ - - �s, _ - — — —.-._ _ E Gid — GENERAL NOTES: `a 1.G`_ F- PS2-01 ,I .'ENrc:}_F . z i A �Ii II - i' 9 I { C �rL, r 1I yy A. ANY lc ALL DEVIATIONS FROM THESE PLANS SHALL REQUIRE THE U— II II l/ I - C F i [�. C 1 7�' APPROVAL OF A CONVERGINT TECHNOLOGIES PROJECT MANAGER OR - i SYSTEM DESIGNER. '-� _ f III I i I c t�t+arv�r�v�; r�a�k� �iivE� C - o �, 95cd }�` .1 _ 95cd-` I F r - - _ ji :; 01 S2- I C 1 911111 I L { I KEYED NOTES: ■ -0i �'� .-. - d 95`d �r - I i 47K H, �� ' BPS2-04 I I (�� Ii i. BPS2-04 i l 1. AHJ TO APPROVE LOCATION OF MANUAL PULL STATION PRIOR TO DEVICE (� �o , k - - _ - - - J � C `a ` I �0 ROUGH-IN. IJI 1 � � �, goonrj Imo .. III J Li - _ 21 r� _ - _ - _ -J . .. a - I 15cd 15cd ... II 1 BPS2-04, :Ps2o4 PS2-04 C I1U ! 71.7 �. El III I I I �� - 1.. .I I I //a—__+ �iiiii/iiiiiiii/ii�iiiiiiiii/iiiiiiiiii/iiia: �.���'■■�` _ I _ �I�J. —�, I I j I Igaalll L.=O I I' ■1 I I I.. I I { I — ril I Pi I I I, I • - 1 . I I //////////////////////////L(////////////////////////f////,I'/� --I I I! - - - H — I-II 0 - - --F - - 1— Ie.Alr� .A___ 'j - — GI 1 I I. � III I. c - • i/ I I i b-o1 { I I I• eP`s2-D1 I I � l _ Ill Q - ., q / ,,,//././////////./////////,//////// ,///////// / I� = • t - - 54 - ---r C — �I �5cd — , IIi BPS2-01 ;•I'l I �I �] I HR TO -., 77/)////////////////////////////////////////////////U'1//../F •i _ C_ NCIERr C I 1 I I . f 2-01 143 ] `,II I I 1 OF'Er�+. r - Lj OPEN ;LES DESKS - II SALES IDES; I �,,L { c., . I 1- = �il I l�1 fr � � --- --�� L I 1171 H CO j a". II D1-15 SHUNT MON ! _.i �'' Il l■ I I I 101-14 CR SHUNT TRIP I I- �F I I I z u I I CR #11. '� 77///////////////////,i////i//// //.////f/////////////////�l/, �MMIE t II 01-13_ RED HAT i I I I w I I 01-10 CR RED HAT #2 I - -- :1 z - II II II 101-12 CR ELEV. RECALL' --- I E - w �d Irl i 101-i 1 R ALT. RECALL _ - - ro ti I - - - - - 0 Lu I , A - - A•l 'Cf o --r' MFCEV •-.- �:: � I m �f' � 2 HR TO MI7eT'� - I' C1° � - -' mo=o 527 LEA I_ z 'MI- 1_1 l r., I _ BPS2 02 _ A -� � 11 � .' I I I + ■�i -11 i BP52-02 rI _ 3 — RON PULIOFF � I I• 47K 30cd I I C 30cd I_ _ 30cd ��_ IL 30cd it BPS2-02 t—.r _ HI 30cd VZ '�� 1. �7 •-".„..-4BP52-02 ♦i i 1-J ! ````'''I' ���� 1.1 I I 'it/-• % . //' / //-/////. ////////////////////////////.''J { -Ii -- I EE , 13 5 I -� ' t-� - a 1 I 24 I r j4 I _ I _ J_- ��■� _:.111,117,--Lr i 1 ■II - ", F u --1' .� b111 I I I �EI- 1.1 iIt1!mi1r III _ ,i — I I I N ��� � I ._1:,' �� - r 1 --I f+, Int -- . ., �� T 4;C N Mel_ III = I W . o—C - n �I- r VII _ F,i I■1 WIRE SCHEDULE w �� ®1 - H` �; I - I . o --1�� -_ ' ' �1. I - - . - — - - - - - LETTER TYPE USE _ `. - 1�- -_ •M -• -'- I - ,: — `^ ;'i/.'i////////,i//////////////////////. ///.•, :!ii%'///.'/i; 1'-15cd . I A 1 PAIR 16 AWG- TWISILU FPLP DATA LOOP/NETWORK F fa - BPS2-02 C B 2 PAIR 20 AWG. RS-232 i m ¢ I re-1 S2'O2' I I El< I BPS2 02 I I C 1 PAIR 14 AWG. TWISTED FPLP BPS CKT/24VDC _ 3 S E 1 PAIR 16 AWG. TWISiW FPLP AUDIO CKT L.HU - a 1 14 I ) I ��l 1 1 ) E ._ wig I h II v.HdcLE — 1 i Z Z I VEI-It 7 SEE FA0.1 FOR WIRE SCHEDULE NOTES & GUIDELINES. • m J ) 114 -- - -I o S = V IJULf U WOMEN'S RR o L, � � .DISF?F_.a.; . NrEN`5 ��-__ i � REVISIONS �� I ///////�////r/////////////////.i/ ////%i:•/:'/ // //-%//. %k C i i 1r� I 120 1 Q Q i C { 4 �{ REV DESCRIPTION DATE APPROVED 0 1 OEG REVIEW 03/20/19 R. PULIOFF 30cd Ocd o-C - o-� - BP52-Q2 3 11_ -- w PS2-02 I - � -- I I ; I _::,o DRAWN BY: o t. I -6 - C D. SQUIRES i I I d - I �1 I E_ :� I I C 11 1 7 S2-D2 (} _= 1-J i 1 '1, -r1 BP52-o2 Vi//////////////////1//////.///////i///.///////////////////1,/ PROJECT ENGINEER: B. DUFFEL riri, C ,I ;' 1 C I _ _- PROJECT MANAGER: R. PULIOFF B NUMBER: ___ o 6 r _.. _. . _ ___, L__:. i o--i I y€ �, HOP DRAWING SUBMITTAL DATE / 01/25/2019 F LT_ t Fr ter,. -.- ^.�+. I �_ /1 : 26 CONTRACT TYPE: PLANS & SPEC:LI DESIGN BUILD: ■ - - r s- I ,.�",. :.� WTI I I I I L �c,,,.,�,,,�,:6.1 a.,,oidv.,�i j* �uc _ . - PROJECT NAME: • 17 JAGUAR LAND ROVER I I I I 1 1 I I I I I i 10125 SW Washington Sq. Rd. Portland, OR 97223 NORTH c I YSHEET NAME: 1I I I I I I I PAVILION FIRST FLOOR FIRE L..1 ALARM PLAN - o CENTER rr. o 0 0 SOUTH S''' DRAWING: 4. FIRST FLOOR FIRE ALARM PLAN — SOUTH SCALE:118"=1'-0" SOUTH (I) FA1 r tM!P66I111IMMIPrI 1 A Key Plan „, 0 4' H' 16' '41 z ca a w J L CUSTOMER NAME: OEG ,Q, Ci) ( E 1 ® 1709 SE 3rd Ave ! I Portland, OR 97214 - f+i I ! ii-_:, � 30cd 140 I�/` T I ! 1 I 1 140 I ! i ! 111 1 iX�'— -.. SPS?-01 1 I i ' .7/ / 1, y� 'I - %_ /MATCHILINE: FA1.1 C I c. . — — — 1 -1 r/ •_; it 4 / MATCHILINE: FA1.1 Cvv-----:------,00.‘j:/-7-0 O ---.- _. — c ----f— ++ �� - •4. . MATCHiLINE: FA1.1 B ,`at • / ,01!„ MATCHILINE: FA1.1 B i i I i 1txd ie n �` I I i r Is1.gF51-61 •/7-17 1 • II } _�, 1 11 1 11 11 1 I _ -1 Ilo ! 1 ' 1 I TEC - • • ES 'I I' • " ••F'.. C C 1141 7678 SW Mohawk St Tualatin, OR 97062 - ?._ - - f Phone: 503-228-8522 Fax: 503-228-8521 I • !� I I ': I \\ c II This document and the information/depictions contained/shown r t �I 1 is the exclusive property of Convergint Technologies LLC and 0 0 shall be handled as proprietary and confidential information and _ I � i p n I 10 �� i : ; oon 6 -- - "� I of �. — _ — — —. — — — — Irt — — — - — Convergint Technologies LLC. T \ - �_ lY1 Illi � — ; 1g� ► I I II 1 1 / I ,,'�1 �� 1 I 1111161; GENERAL NOTES. Y � !�I � k--'----. . 'L— I I + i •. . 1! Fr . R O A. ANY & ALL DEVIATIONS FROM THESE PLANS SHALL REQUIRE THE -- \ CAR V ASH I + C-,-i _ 4? C ' APPROVAL OF A CONVERGENT TECHNOLOGIES PROJECT MANAGER OR /./lf`'' 1) I i I 1 _.4 ••,..„ _— 3tISd t j- q ! ! SYSTEM DESIGNER. KEYED NOTES: 4 K ' -Li ;� J L___ — -_ 1. NOT USED. ✓. \/ _ _� �" `ni A I ! I I f I I \� - �� I x I I ! ! I •••• • r®2, i� ti 1 �� I I u, 1 I V z I 1 I y I 4 I PIVill \- / iii:-' � ll ,=,...-,, I ."� I - — ` I / 49 I + 1 / /1/ - _� /! 0 fN . ' i 1I I 7!1!� I I. -- 1 • / / - ! p F1 _ I �/ di I I � it I , -, : : , I r. •� a � � \ *rot/4, 10- *If 101/11,1111c, / LL_ k /I fill 1 f l -1 if � ! 1 I HR 0 I „��B'Si-t2:11141,11111;;II:Ir1asi �� ', ` _, \` ., .., ,..„....- m_)_2,. OM, I I ;-L-! , liiiI,- - ,--::--.-"---,.........„.1.,-----__ --6,---- ' ' 1, '," : ! 1 - .,_-__1 1 - 3- I INIESEEMP ' 4.460.40,40/^ ,,-._. ,,,c-s2. 7.,....0e.. _., -_ z 1M .---- k.__7-.i , 1 1 1 i x l TIM i IM _ !�SI&A� tilCi r i ___ 1 1 1 1 1 - 1111111111ML94 4. ET g*/* 4 8 4°I:-.'""'"''.' --:-.,,, --, it, ,_ '1 ----- ± 01-Os- SHUNT A10N� hi 1101 I• I I j 1 01-07 CR SHUNT TRIP 1 I ., lef. /...", .1'.7... .,,-� ` '/ L 101-06 CR RED HAT #1 1 L- t'- a• '- ' % Z «I __ �r w 101-03 CR RED NAT AL2 I i I T o.0 \/ ''' / , o o , F � = OS-04 CR ALTE�RECALLL �IEllin __ /7 1 j r.Lilli ''IIIIIIII;*Aill 1: a / 527 LEA \ - 1 1 ]1 1'►nFCEv '' Nom■ RON PULIOFF STAT- dirt. itir ' c, \ 161 . ! - aid+ 1i- — mea rt.., *Alviriviiri*AP,---..towtifte;;w1474't/o i ..._ `° ELEVATOR 2 nU =UllZIP! / /1;f _, 0 \ - _ 162 �, / I � i:= l8 �� .;.Al#Air//7*M / W W / 111.,‘„r#4,0„4,/, ,�\ ! 1 ® � /, WIRE SCHEDULE ,__ ! ) I 46'A•5H —( u Mil -- ��> i� A' LETTER TYPE USE CZ 1 .1* 38 �i1 *titV� / ' :`J' A 1 PAIR 16 AWG. TWISTED FPLP DATA LOOP/NETWORK o \ 1 ' 1/410011•71/.1/ ♦♦♦♦♦ J / B 2 PAIR 20 AWG. RS-232 j �/ �. 'I MIME- / *it / / C 1 PAIR 14 AWG. TWISTED fPLP BPS CKT/24VDC 0 I minim � / �44f# ♦/// E 1 PAIR 16 AWG. TWISTED FPLP AUDIO CKT w i �\ i /A� / /******/ SEE FA0.1 FOR WIRE SCHEDULE NOTES do GUIDEIJNES. 4,/7.�� � -. / � REVISIONS I I /*/1, j >.-- ' i /l ** /*/, 4*--- -itwo,,,c/,' i'� // REV DESCRIPTION DATE APPROVED o r-- ` -- / r . A1 / 1 OEG REVIEW 03/20/19 R. PUUOFF CO L - I 1 1 / a, ♦ / �% 1 WA H / 7 y "oma / �r.:.`' I / -,,, \ , 1 c=r—C 1/ 4,, 11*,11t1t/7/ 14 - - - I 1" j `y r _. **Air // .**/#1 �f**W44*/// DRAWN BY: D. SQUIRES o ��� �I w13 H /�� I I / /t PROJECT ENGINEER: B. DUFFEL 6 �.' / [�,.,�, PROJECT MANAGER: R. PULIOFF i vi. / I I i41.4774,47/� JOB NUMBER: 302 FN H0641 o � — I / / atlftp+ � � / ,/� SHOP DRAWING SUBMITTAL DATE: o1125I2019 Z �% ! ` 1 / \ / / / ?///41V / / iiiitW/ %� ♦��/I/ CONTRACT TYPE: PLANS & SPEC:0 DESIGN BUILD: ■ I ! \ / / ,7 / i // it*lirb. /Sit* lip� i PROJECT NAME: T o ?1I}I/ — — ti' rte,. - E� Y...._ ._..v. -I \ /�! `5 / 11r4s*/ ' ♦`. 15 - - - - ,: - - �,J�irS►iti♦� JAGUAR LAND ROVER 1;v411; 11107//// 10125 SW Washington Sq. Rd. / ..4.'. /_ llirit k,•t f 4 Portland, OR 97223 1 / ; ja pi t/ . NORTH /41. ♦t ����/ / :i *tr �♦� / SHEET NAME: fri — '/ I I / / p �� N � ���/� PAVILION FIRST FLOOR FIRE r., / -- 4/7„.4,,44140.„..„,�._ / ALARM PLAN - / 'mss :. �/� ; ♦ �'�� / CENTER CENTER :/,,,,..,i-_-: / :;I ` /i DRAWING: FIRST FLOOR FIRE ALARM PLAN - CENTER SCALE:118"=1•-0"(ID [� /f /' N dt*4Y**1 0 4' 8' 1 6' �� S' s, FAI . I B / SDUTH o. u, z � Key Plan CD1 s, a CUSTOMER NAME: OEG 1709 SE 3rd Ave Portland, OR 97214 A OB C C E F G -_•e Co J r;J,l % nt I I I I I I I TEC - • • ES • 7678 SW Mohawk St,Tualatin,OR 97062 -I r-I Phone: 503-228-8522 Fax:503-228-8521 • - fi y I..r, �Af•, C�_ ) i , . I , This document and the information/depictions contained/shown i :.I i�� l i 1 I 1 FLUIDS 1 % I is the exclusive property of Convergent Technologies LLC and I 155 I I I 1 ;'; I I shall be handled as proprietary and confidential information and �__ :__ -- -� I I I must be returned upon request.This document cannot be ' L __-_,,_i k i reproduced by any means without the written authorization of TOOLS i � j j s 1111`�� ! Convergent Technologies LLC. 1 151 I •,�.; ��� 1 �_ I I GENERAL NOTES: \ I _ 1 I A. ANY & ALL DEVIATIONS FROM THESE PLANS SHALL REQUIRE THE • I I K ! 1 I I C APPROVAL OF A CONVERGINT TECHNOLOGIES PROJECT MANAGER OR + �+ I 'I 1 SYSTEM DESIGNER. q• 71 i •' S C lj::"y I i KEYED NOTES: C --- —+—f..__—_,-,—.- _= _- _- _ - - - --- -- — T_— _- - — =- CD 1. NOT USED. r-1 „' — J - - III 1 l I _,_;r' _ I I P=i •-� � -moi 1"r- �, �-- X, Q 'I ! r ,r „ 1 I iI C - - - - II II 1, - II - - - t - - I f- - - - - III - - - - - - III - - - - r� - - - - O3 + I I I ' - 11' I I � LI, y — j' I I I 11 1 1 ! �y , a 1 I II. I I rk-i"; l I� .+ ..4-i 1-----111 I PARTS I STORAGE - I I � QH . 15' II o i6 1; 1 1 III -- C - - - - II Ilfi' — - — - - II II- 111 - - - - - - III - - - - II' - - - - C L II II. . . _ii 11, 1 E r--- ( IS ER 111 I I !El Lu L--- ' 131 I 111, 1 1 1 l\i li • !-1 I . III T1I-' ' 1 i—icc, ,+' I, , ,:II Z 527 LEA I I `,�� ��. ,4 -I 11: 1 _ ' r �1 ��1 RON PULIOFF I 1, C - - - - II IIII - - - - - iI Ifs - - - - EI - - - - - - II - - - N - - - - C 4f,t ,041 —k rte ' ZW- F-11 I - h/ qR . i�� 1+ +1 / p° 2� 4 PI SEQ II'' 4tL7S ,r ONII 's II` 4r Q 1-- . Il'1 WIRE SCHEDULE .-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-. r �� ' LETTER TYPE USE I o I I ' _ i l \ 1 r ��� N - A 1 PAIR 16 AWG. TWISTED FPLP DATA LOOP NETWORK ��' ts�� I I TIDE 1 11 a. _ IIL / v 6' - __EAG - �, - \ C 1 PAIR 14 AWG. TWISTED FPLP BPS CKT 24VDC B 2 PAIR 20 AWG. RS-232 sTo, E 1 / E 1 PAIR 16 AWG. TWISTED FPLP AUDIO CKT :+ I ,III +� I I lJ I I // � yyy� / I N 6 . I I I / ) i " / SEE FA0.1 FOR WIRE SCHEDULE NOTES do GUIDELINES. o \� �� I �C l �,jil / 1 4/41- REVISIONS Y C 11 II Il - - - - - - - - - III �" I - - - - C 0 6 - - - - \ 1 - Vii! i /` o I I I \� C� �r , .i REV DESCRIPTION DATE APPROVED j „ I 1 I 1 \� / ��_� '' i�•� '%':~`'' 1 OEG REVIEW 03/20/19 R. PULIOFF a it .�\• I i ,_: = I I I �r STAiR 4`, o • - I I \ — _= ==- :i I - +-'' I I I SECURSECUREDD _\ 163 ,, +N I I / ' \ I• , I ,y,1 1 I I I 144 I � Is ti is I, 11 4_ Q� r [ II � 1HRTO I� / I 4 I - -- —L H P4KT� ' DRAWN BY: D. SQUIRES ! _: i � - BPS'-01 ! TI r 1 11 Z I I 1} _�__i __ " _ i (3 I �/' PROJECT ENGINEER: B. DUFFEL o L - I 1 rr , — C-0 A- I : ;I r ( P I 1 ff \\ b' PROJECT MANAGER: R. PULIOFF 9 i I . ! •-1 — i -- t F �'1� I'M C c I I 1 _ JOB NUMBER: 302-FN-H0441 9 �,L ji- s"-+- ' o I I i 1 1.� - f 1 iit �uii 30c 1', 1 1 I (: I I 1C A\ I I _Jul I I I I I - ' I SHOP DRAWING SUBMITTAL DATE: 01/25/2019 j OF 75d '%i I -I I I j, I I QBP.1-01 I 4 I ' CONTRACT TYPE: PLANS & SPEC:El DESIGN BUILD: MI 1 I' I I I— II:.! I I I PART E% 1 10 I I 1 ;1 i I —I I, III. , 1 ( 'gip 1 r; / bps PROJECT NAME: te,/ . ..____1_,• .„, C - - - - II Ili; '�- 4., / ! I �' JAGUAR LAND ROVER 6 i' -_i___,,,, _ --_�pMEN'S RY� �� �� 1/ / 10125 SW Washington Sq. Rd. Ili: i 139' i • 1 ♦ �� a + I +; �_ � '� ��� 1 " `� Portland, OR 97223 4 sl I ; ;: F ;;� /�� •,� „ , b \\,i /// NORTH 66 1—Q � y I I I I -�1 ,, r /�” I I SHEET NAME: — 1~15d . _ '/ mow I I Do I I I—@P'•5r—t!t it C r- /�,- 1 %"_ - �j � . - G�<-- PAVILION• FIRST FLOOR FIRE ,„iii . I _ BPS1-411 �� 4/ >l I o—C MEN'S RR �7 + I I a H1 R I C �� coed - 140 r/ CENTER ALARM PLAN — I: I I I 27 1 -Zi '! r a-a- " �� BPS1-01 I I NORTH _ _ MATCHILINE: FA1.1C _ _ _ — . 1 - %%�'-,'. _ iv.._ _ MATCHILINE: FA1.1C — — I _ _ _ _ C MATCHILINE: FA1.1 B —� 6 MATCHILINE: FA1.1 B • I I ,4 t a I , , __ I`�R5cd—n� - 1 .1 II . - J — DRAWING: N L,- FIRST FLOOR FIRE ALARM PLAN - NORTH SOUTH (1") FA1 • 1 C z SCALE:1/8"=1-0" I I i .... iii , , i i Key Plan ■■■■ I I I ■MEMEIN i■ 0 0 4' 8' 16' cnulLU J • CUSTOMER NAME: OEG 1709 SE 3rd Ave O L Portland, OR 97214 TE F G _ 2-7. co A //v/. nt Ale I I I I I I I - TEC - • • ES 1 7678 SW Mohawk St,Tualatin,OR 97062 Phone: 503-228-8522 Fax:503-228-8521 p! ,,,„,-„,,,k4 ` I This document and the information/depictions contained/shown i u rl,-+ I I 2/ I I = I i I is the exclusive property of Convergint Technologies LLC and j' I I I I I shall be handled as proprietary and confidential information and I i I j I !! ; I I I must be returned upon request.This document cannot be I I — -- — — — tr—� , , , t , =- I I reproduced by any means without the written authorization of L, t � ; t ! 1-----,,—,_—_ !j I Convergent Technologies LLC. 1i01.18 I I I GENERAL NOTES: - A. ANY & ALL DEVIATIONS FROM THESE PLANS SHALL REQUIRE THE I I I APPROVAL OF A CONVERGINT TECHNOLOGIES PROJECT MANAGER OR Wo-A SYSTEM DESIGNER. 1 iil li I� I r r, ij1 ,__ , , , , KEYED NOTES: �FACP TG7 lam 1-23 TG7 MONTTtiR�----T- LI- r-- r t. NOT USED. 0 �rII EECT I I I 11 11 i I I ' I I II 1t II I \ - - - - I I — — — — — — — — — — © - - - - i �W — — — —11 ii - - - - - - II - - - - d l':g — — — — j 1 1 ii I I I I I i ,Ii, 1I, I I 11 i t iI I I II H I TAL c� 1 C - - - - II - - - - -- F - - - - - - - - - - I �4= - - - - III - - - - - - III - - - - I( - - - - i I I 1 'I1 I I I W 1 I 1 CC N !II Z !I' CC ! I I I I Z I I i I' I I I w L___ Z I ill Z 1 W CC WCD j II I I I Ci I I I I 527 LEA i III RON PULIOFF a �' S - - - - II - - - - IF - - - - - - - - - - I � j1� 1: '- - - - Ii - - - - - - II - - - - 5 - - - - 5 I I I I ' 1 I 1 I I // I I I I I I // CV 11 WIRE SCHEDULE ,111 i I / \� LETTER TYPE USE H7 A 1 PAIR 16 AWG. TWISTED FPLP DATA LOOP/NETWORK I \'/ I / B 2 PAIR 20 AWG. RS-232 c‘iN I I // I / I C 1 PAIR 14 AWG. TWISTED FPLP BPS CKT/24VDC / bE 1 PAIR 16 AWG. TWISTED FPLP AUDIO CKT o w I / i % 1 1! / / I ,/ jSEE FA0.1 FOR WIRE SCHEDULE NOTES & GUIDELINES. -co ' I 7----r... „,,,. ._,,,...„. \\ I �� !` I REVISIONS - -o I - - - - -- - --� -- ___,I, /,— — — - - — - - - - o _ ; — — — — I�� — — �_ r , ____' I j - -------- --- — //" / ���\ I{I / I REV DESCRIPTION DATE APPROVED Do \/ ` Ot-31 rf' �\ / \� i / 1 CEO REVIEW 03/20/19 R. PUUOFF 1111--+ I � I I �__ ✓ . n -t I!n I;r' A _= J - / D. SQUIRES + 1: DRAWN BY: �' /' PROJECT ENGINEER: B. DUFFEL II Z r-- it--- --', i � – ' 01-32 PROJECT MANAGER: R. PULIOFF Q ? r i sl, p ci / JOB NUMBER: 302-FN-H0441 J I I r,�t���41/ A� L� - .. i 94 ! I /" I HOP DRAWING SUBMITTAL DATE: 01/25/2019 1 1 / CONTRACT TYPE: PLANS & SPEC:Ei DESIGN BUILD: MI �A illist,/ PROJECT NAME: \ - - - - II - - - - Q - - - - - - \' ' - - ' JBPS2tlol33 - - III I - 0 JAGUAR LAND ROVER I ISS y j J 1 1 / 1 j 10125 SW Washington Sq. Rd. NORTH Portland, OR 97223 . /co CO k o-, I II I SHEET NAME: I I I PAVILION I r CV 7. W ;r' / MEZZANINE FLOOR I CENTER FIRE ALARM PLAN I I k / , I I 11 1 iiir1I ; :-.') — _ DRAWING: 1:, MEZZANINE FLOOR FIRE ALARM PLAN N V) SCALE:118"=1•-0� SOUTH F1\ 1 . 1 I\/1 L I I I �E�E 1 1 1 1 1 1 1 5 MINIM ■.■.■■.. ,,, 0 4' 8' 1 6' Key Plan Z . w • CUSTOMER NAME: OEG 1709 SE 3rd Ave 0 \@co 0 0 ® ® 0 Portland, OR 97214 a Q I I I I I I I I Co ' ii7nt CN CNI ' ,.._ waw 1 1 I I I 1 TEC - • • E S Z Z • , _J J -_-.) U U 7678 SW Mohawk St,Tualatin,OR 97062 — — i— ' I t ,f 1 1 t i�j�t E� ' t I I T + 1=�- 1 '- =1; 1 — _it — — — — — — — tL ,�t I r�its ! X11 tf�jf �l I�� t I t J. u i. — rI 16 Phone:503-228-8522 Fax:503-228-8521 !( 1 p` This document and the information/depictions contained/shown Ii `' 1 I is the exclusive property of Convergint Technologies LLC and 1 ' 1 i I I ! shall be handled as proprietary and confidential information and . I I I I j must be returned upon request.This document cannot be reproduced by any means without the written authorization of I.,ia — — — — — — — — — — — — — — — — — — — — — — — — — — 19 Convergint Technologies LLC. EI - I GENERAL NOTES: 1 ` ' p� i i I I I( I I I A. ANY k ALL DEVIATIONS FROM THESE PLANS SHALL REQUIRE THE ��`` i1L 1! _ �J III I I I I I I APPROVAL OF A CONVERGINT TECHNOLOGIES PROJECT MANAGER OR i SYSTEM DESIGNER. B. CENTER CEILING MOUNTED FIRE ALARM NOTIFICATION DEVICE ON I ASSOCIATED CEILING TILE. KEYED NOTES: JCI i i 11 i , 1. FIELD VERIFY EXACT LOCATION OF STAIRWELL WATERFLOW do TAMPER III- _ — -(' — — — — — — — — — — — — — —j — — — — — — — — — — — — — — — ® SWITCHES. COORDINATE WITH SPRINKLER CONTRACTOR. 1 1 I 1 I II 11 1 C i I I1I I I II Ij I I \ /il Ij 1 1 i .17-1-1 I1i IfIiIl� l I ljj 1CD II II II 1 - - - - - - - - IF - - - - - - - 1 i 11 1 1 j III I I II I1 I I I 11, I I I j� I I I i, i 1 I j cu I H Iii I I II I I ! I i II', I I II 11 I I I II !1 CD I% 0.> � i1! 1 I j l 1; I I I Lu z i nal Ili I i ! 1 H. — — i i11 H. ILI0 — — — — Z I — .i — — i i' II _ — — — — L� II - — — — — — 11 11 2 Lu II i ---4--- 1 I -1 — I _4.. ___., IInI �ESto1NT 1151,--,1 � II I I . _ i 527 LEAIli U 1__I I4ATERFLOW 01-37 ` ! II r I -- ,{_ , 1 I � ® I : TAMPER 01-36R — — -al — L.rf - RON PULIOFF I 1; — I d. I A -I ii 1 1 , I I I , — I I 1I j 11 I 1N �1 I I I - —_ i1L j lilif.--7----7-1.111. i ! I ! I I I I ;II I 1 o i ; I Ib --t.---- 1 �1"_ -.1-- I ,.' - I ,I If — 11b - --ill _ 1' , I _ {I , ,1 Ii _ WIRE SCHEDULE 2 03 BPS2 Sli $AIR > I AN,T R - r I j— ®! — — LETTER TYPE USE �—. 2'.8 TORA(E tl COMP/ CO ti W— —� 11 r o—A 1 ' 1 I' IPM 1 213 I 4— ..,----' 1 I YI jA i PAIR 16 AWG. TWISILU FPLP DATA LOOP/NETWORK C m I N ( }3 , 0 3f — — — _ '1101-39 I I I I I B 2 PAIR 20 AWG. RS-232 w QiQ I I 11 q - L. I I C 1 PAIR 14 AWG. TWISTED FPLP BPS CKT/24VfK '' + E 1 PAIR 16 AWG. TWISTED FPLP AUDIO CKi _ 1 I 1 . 1: II�Ii =f I' I :; 111 1 1.\ I I 11 CC -' ENER L c - j Li w 15� _ I r I- �' 11 1 ! I cF Z�Z I I 1 - S ;.. -$�.. - - , 1 11.1.EHI:JFY,..-1j II I 1 1I I ! II I I95od SEE FA0.1 FOR WIRE SCHEDULE NOTES k GUIDEIJNES. it I • �.4B•.2-' 1 '-' BPS2 03 II - 111 1 1 L- 1 1 1 I I 1 ' I ' ' I REVISIONS o I I � Wr I I I I I I I I I I 1 I I I 1 I I �� 1 I I REV DESCRIPTION DATE APPROVED m 1 I 15c I I I �� I I 7---fT \ h, I— 111 I I I I I II I Q I I 1 • I I 1 I I: I_ ®s Rar J "I �e2�1 �f� J I—,II I R I I 1 ` •_ 1 OEG REVIEW 03/20/19 R. PULIOFF I' ! / EN'S RR M Z (— 1 IN INET C C• '' — cal ' I RE1�Y 'C — $, I . l5cd5cd 1 I �i 1 I I"°� 1 Lb 0 1 I I I I I I I II I I ��� BP -O S� � �Y BPS2-03 �QPS2-0 �I�P2= 3/ I • T Jro I I I I IIII IC' I 1 1 ii► `�"■"' ICI 1 D — C /--\-."'" .. '''-'''r..-' i ir I I I DRAWN BY: D. SQUIRES sI"Es' N \ I (-----__ 1 I �y �� T t I r PROJECT ENGINEER: B. DUFFEL g —i II I _ ?. _ _ _ Q � I '— f' —'\1. �f'— ` I 1 I I I I I PROJECT MANAGER: R. PULIOFF ��iti — i�I —.: /S h_, I'��) %�`, A I I:eili ——— ,_ H—J JOB NUMBER: 302-FN-H0441 fl ip SHOP DRAWING SUBMITTAL DATE: 01/25/2019 } '� I 1 I 1 I I 11 hI IM ® CONTRACT TYPE: PLANS a SPEC:l DESIGN BUILD: IN -- - PROJECT NAME: 1 1 I I I I I I JAGUAR LAND ROVER I I I I I I I I I I 10125 SW Washington Sq. Rd. Portland, OR 97223 CO NORTH C6 rzn 1 I I 1 I 1 I I '---/ SHEET NAME: co I I I I I I I I PAVILION SECOND FLOOR Li c. FIRE ALARM PLAN - CD J K L) "A CTv j P O R CENTER SOUTH - • / DRAWING: N SECOND FLOOR FIRE ALARM PLAN - SOUTH Lu 5 SCALE:1/8"=,.-0- FA1 • 2A G I I I ■■■■ 1 1 1 1 1 1 1 SOUTH (1) ■■■■ III ■■■■■■■■ , ■ („ 0 4' 8' 16' Key Plan 1, LJ CUSTOMER NAME: (A) + ) - 4 1709 SE OEG 3rd Ave 0Portland, OR 97214 Z-' / ""/61 , I I i I /' j// _ _ MATCHILINE: FA1.2C b.___•,' _ _ , _ _ — I __ __ ,. MATCHILINE: FA1.2C — _ _ _ . — — - - - - C MATCHILINE: FA1.2Bn t MATCHILINE: FA1.2B10 CO // %/' 1 ;; I I �,� I %� 1 I TEC - • • ES / � (/ 7678 SW Mohawk St,Tualatin,OR 97062 Phone: 503-228-8522 Fax:503-228-8521 I NN I // I I I I I This document and the information/depictions contained/shown \ • is the exclusive property of Convergint Technologies LLC and .\ �� shall be handled as proprietary and confidential information and must be returned upon request.This document cannot be � --, ® I I reproduced by any means without the written authorization of — — — — I' �l — — — — II' — — — — -Hi — — I I — �" — — — — — — — — Convergint Technologies LLC. %/ I I -'' ` / % GENERAL NOTES: /j �' 77 A. ANY & ALL DEVIATIONS FROM THESE PLANS SHALL REQUIRE THE ' �// APPROVAL OF A CONVERGINT TECHNOLOGIES PROJECT MANAGER OR I / / I I SYSTEM DESIGNER. I I // 1 I I KEYED NOTES: .I / /Z 41/ 1. NOT USED. CO ii • / //''' ', /% / . � '; ! / II -o - - — _ = % __ __ - — / 11 \ rQ / - \ i ' ,2' — O— III / /I 1 _ ,' /%/ / O / I \ / r //Y \ / /// ' / I 1/ // 1 \e• \ \ Q / I, ,/// \ .4.- ..- .,„,...j ----., ---, '-''-''''''74';,-41 W 2"/ I o \ \, Iil /// -----/--- �\ c, Tr I 1 jr r / /\ w . ,L./ \ 0 m 527 LEA �T I � r I / i %.�---.. --/.. `----,,:i / //' ,�' RON PULIOFF a — I I �< // / - / \ / i/ 12 --_— y I --f7-1— .Z7 / 6' / . 0 1// / -) / L 4',../Z '''''/ Ji/ / \ I > \\ // ��,>; //7' WIRE SCHEDULE L--- \ , � LETTER TYPE USE / i ; co "%/ V` �..\ / ,`� / / \\ / A 1 PAIR 16 AWG. TWISTED FPLP DATA LOOP/NETWORK <73 /// / // / B 2 PAIR 20 AWG. RS-232 \ \ \ C 1 PAIR 14 AWG. TWISTED FPLP BPS CKT/24VDC w \ /% / \ \ \,-; ��// E 1 PMR 16 AWG. TWISTED FPLP AUDIO CKT 13 - - - - - 7I -- 111— 'j / \ / i I :j / j/ // m / \\ / / SEE FA0.1 FOR WIRE SCHEDULE NOTES & GUIDELINES. 1 /1 / / --„, I '' i/ 1 ':',/ i REVISIONS 0o r--- j / \ \ \ �3/ �/ '/ REV DESCRIPTION DATE APPROVED CO L--_ I / / / 1 OEG REVIEW 03/20/19 R. PUUOFF / \ \ 15 7 " / \- I / /�/ /' . o_ 14 �: N. I'I .• /�' / / /i \ / DRAWN BY: D. SQUIRES „:// / PROJECT ENGINEER: B. DUFFEL r \ PROJECT MANAGER: R. PULIOFF o NN / v ;' JOB NUMBER: 302-FN-H0441 J /J r--- 1 \ - , ! / / /'/ / / \ / / / SHOP DRAWING SUBMITTAL DATE: 01/25/2019 �\ \ 4 / / ./ CONTRACT TYPE: PLANS &SPEC:0 DESIGN BUILD: MI • y I / 4/›/I'7 // i / --------0.„ -0.. v �I/ PROJECT NAME: x \• GO H r__ - — JAGUAR LAND ROVER ----- -� ,.,, �.3,IY_ - i�tr'-=-i'4 :S_J![rirAvv --- - IT--I'_,/!y / �� l / :./ /% / / /' �, / ;%'// 1 10125 SW Washington Sq. Rd. _ '= / , Portland, OR 97223 CO /` `, \\ \` \ / \ I / 71/ %/ NORTH Oci / o / SHEET NAME. 0,4 / \�� / 00 / �/^ PAVILION SECOND FLOOR . / '4/, 4r �// j FIRE ALARM PLAN - %,�/ CENTER CENTER SECOND FLOOR FIRE ALARM PLAN - CENTER m�� 2' III .... 1111111 Q J Emu. I I I .■■■■.■■ �/��Q 1 0 4' 8' 16' ‘4../' / j� ,,� // DRAWING: ir ,s,.. //' 4* N c LLI WVSOUTH FAI . 2 B Z -2'! Key Plan W . • CUSTOMER NAME: OEG 1709 SE 3rd Ave Portland, OR 97214 .. .--.. CO nt , , , T E C - le • E S 7678 SW Mohawk St,Tualatin,OR 97062 ri Phone: 503-228-8522 Fax:503-228-8521 1 I r 1 0 - - - - . 1— , 0— — — — , -1- i _ , // / II This document and the information/depictions contained/shown . , / ., I " / I , 0 II is the exclusive property of Convergint Technologies LLC and / ' I I shall be handled as proprietary and confidential information and I ,./ I • I , I I must be returned upon request.This document cannot be . / . . / I ---r---F-77-7-7-,71-'-' 77 , 7— i 1.1 reproduced by any means without the written authorization of ,./ , / l ! H-Pli4 lii ! l ! II Convergint Technologies LLC. , , . ! '‘. ' ' " 1 " / ., ,/ I li / .. GENERAL NOTES: I > I / I / p , , I A. ANY & ALL DEVIATIONS FROM THESE PLANS SHALL REQUIRE THE 7 li APPROVAL OF A CONVERGINT TECHNOLOGIES PROJECT MANAGER OR / 11 SYSTEM DESIGNER. i 11 / - , 1111 KEYED NOTES:- 1 , ri ______ __ __ - ±.---i, L_,-- ® ' --------r.,------ -------- --- ----",.E.--- -—i..--:---.-—____....4-- -7--------- m--------, I 1. NOT USED. i1 ---- ; --_-__ •I .. . • 1 .,. i • ,ii. t• _ ---, •;! 11j, N ----. --._ --, , ----., 11 I N 1 ® , , , ,,1 ------,.7r: 4.1, j-HI-. I I H . 13 ;-,.1'1;I. - - ® .,, 1 I , .. . . .y , • , „ . , • • ,/' ',I 11 ,-- - I , 1 i / ,/ I . . . / .,‘ , // 7/ z / ,. . I .. . /' / II / ./ ., , ''' / // . / il / / ' ,--- -'7 0I I " - - Iii - - - - I 'I I I '1 - - 0 1,_ 7 I I I I \I • • I< 1 I 1 I 1 1 , I cn . CD I I ., • • < . ,: r '-‘, , •• •.,..D . \ \ :I Z . w r• s, 1 . I 1 . i z LJJ 11 . 1 CC I 1 i i I LIJ 1 1 1 CC 11 ..,, • \ 1, H I 527 LEA 11 .\ ., . . \ i RON PULIOFF . ® - - - - :: I .,,I ===--- _ __-_-.11._---____11:7_-_--- I I I I 1'3°1;111 ® 11 ,/ ,i- cp 11 > ,- , , 11 = / / ,' / , I z 1 1 .11 : . . •,. u_ .- 1 , • c‘i i 1 ! ' / / \ , 1 , 1j.1 , ff) ii / /?1/ WIRE SCHEDULE ,, ..--- / ,,._.,,,,. . 1 / / LETTER TYPE USE ..---- -7 co /%--....„., / . , . 7-. A 1 PAIR 16 AWG. TWISTED FPLP DATA LOOP/NETWORK / ,i /i'', -------- / B 2 PAIR 20 AWG. RS-232 CV I / 1# '''''V cn ,-. I 1- / l C 1 PAIR 14 AWG. TWISTED FPLP BPS CKT/24VDC . (....) i; . ,•• I -1- - / /if / ' E 1 PAIR 16 AWG. 1W1STED FPLP AUDIO CKT c7) 7;/ / I 1 / /;--' ''' A' / i- --- 1, / /,, ' if SEE FA0.1 FOR WIRE SCHEDULE NOTES & GUIDEUNES. /t'', / . , 2 ! ,-- 1 ,' , , ---7 i ---- ,i REVISIONS Li / Q Y -41-11 4- 71 1 t I I 0 0 0 ' ----VW— / ,/,--,..,....- 7,,,.., --.,*„..„7-; REV DESCRIPTION DATE APPROVED o co 1 OEG REVIEW 03/20/19 R. PULJOFF ,----- , . _ ,//' I "----, -..y. ¢ \ . o / 1 1 \ o \ .... , .,-, ----...„2----,,, / CD 71 \ , „,6-- , I , -- ,'// DRAWN BY: D. SQUIRES \ /// , //,'' Z , / PROJECT ENGINEER: B. DUFFEL \I 1-= 'N 'N , PROJECT MANAGER: R. PUL1OFF < \ . 1,; o , o .z,. --. //7/ JOB NUMBER: 302-FN-H0441 .__I \ ,, ,, I L...J • r..,. . //// SHOP DRAWING SUBMITTAL DATE: 01/25/2019 .. s LT- -1 \ N / I CONTRACT TYPE: PLANS & SPEC:p DESIGN BUILD: El . „ ‘;-;„ , N , N J /il 1/ PROJECT NAME: . .. , ,,, ,,,,, 0 •:„: —11,_ -i--1 -1--i— - , ,c, -47 t_---' _ ___ ____ 7 , /1 ' JAGUAR LAND ROVER _..... ./ I /.,///;71/ / 10125 SW Washington Sq. Rd. d / > ,/ ¢ Portland OR 97223 , ,/- , . -, / NORTH 66 :I / I .1 / ,./ .cip 1 -•1 / . ,7 /// SHEET NAME: c-.1 i ---__ il il .,” co // /' CV / ,/ PAVILION -......, , , SECOND FLOOR r,) / y / . ii4/' . cz, . . ., 1----- ,/ , / / 7 ,/,/ FIRE ALARM PLAN - , . CENTER o / I NORTH ' ./ • I / / z /t% 1 MATCHILINE: FA1.2C • / _,,, •' / MATCHILINE: FA1.2C 0 ® _ _ ... __.- — — — — — — — -1.H ., _—_— .- — • MATCHILINE: FA1.2B - I \ -TI -,,.., _ i ---) MATCHILINE: FA1.2B DRAWING: . , 4\ <:. •<" . . — N cn u.i . SECOND FLOOR FIRE ALARM PLAN - NORTH SOUTH (I) FA1 .2C cn SCALE:118"=V-0" „ , .... , „ „ „ Key Plan , , , .... ........, cn = 0 4' 8' 16' c, tf LU (./) D I . CUSTOMER NAME: OEG 1709 SE 3rd Ave \ L N J [D Q Portland, OR 97214 ro 1,-) Co ArivActo,' n t ,:_, ., TEG • • Es Ili l� I I I I Z � 1U- _ -----.._ __.-__-__T____-__-____ -- -- T-. ___ -- -.- 7678 SW Mohawk St, Tualatin,OR 97062 1c 1 -F--..__ ___--- _-- -.--- ---- - _.__ - I _ - A - _ - - Phone: 503-228-8522 Fax: 503-228-8521 ,{_i -� I 1, - r - _ - - - r - - - W - - -, ,,,., ,' \ - - - - - - - - - - - - I - This document and the information/depictions contained/shown • ___ e L '{ is the exclusive property of Convergint Technologies LLC and . - --- J shall be handled as proprietary and confidential information and III i I I I I I must be returned upon request. This document cannot be II - I z- - I – T I I — — /:% I I reproduced by any means without the written authorization of _— T _ - - - — - _ T - - - ' - - - - { ,- . -- I Is Convergint Technologies LLC. I f% ! I 23' am• , GENERAL NOTES: 1 I I I I i' I I I A. ANY & ALL DEVIATIONS FROM THESE PLANS SHALL REQUIRE THE 1 APPROVAL OF A CONVERGINT TECHNOLOGIES PROJECT MANAGER OR 1 /%� I I I 'N �N I i' I—. 1 I I i 7 . N I KEYED DESIGNER. N / \ i� 1. NOT USED. 1 r I I I t _ \ I 1 I I I I I _ i _` / LVJi ■\ I I I I I -- I I ` I 1 I I E �_— II 1 r 1 7�T TWT.._ J I _ _ I I �� 1L I r{_ - - - - - I I---- 15 r ---r, -- a-)T I 1-- eI 1 - I II 1 I i I I I I I 1 I I I I ! LL ___A.'t �L __�� I I I I I j ' . _ - --- I I I /� ---J II - I _ I \ I I I I f ■ -T I 1 H i / I I 1 -� 1 _ \ I a T I - - i - - -- 3T - - \\ - - - - - - C, �' W r-1 =1'1 i I i i k I � ' I 1 I `- 1 I I LulijI I I I- I s r I Y.-I - ; r • w i I — ; i - -b, t- __J � I I _ - - / __ - - MI 1 +j II I I I II I A ®.. -I-_ I- ! -- I- i _ II j J o ili_ f z - h. LII I 527 LEA I - _ _ RON PULIOFF ,-, ---r_ - -H I1 j I —�i I� j - '1II l i WIRE SCHEDULE 11 I 1-- ,_-- -- , --- -� ___ --.j_.L -_ ��'�i�-L_ �"-"� " __ __ - - - _ - - - ------ - - .- ® LETTER TYPE USE ,T..._._- ,.._—____i_4_47.... ,, A 1 PAIR 16 AWG. TWISTED FPLP DATA LOOP/NETWORK N) I I I I B 2 PAIR 20 AWG. RS-232 j r7 I I I i� `. C 1 PAIR 14 AWG, TWISTED FPLP BPS CKT/24VDC Q I _ I I I I E 1 PAIR 16 AWG, TWISTED FPLP AUDIO Ca w u1� I I ! o o ! I cL �,j L;j I �� SEE FAO.1 FOR WIRE SCHEDULE NOTES & GUIDELINES. 2 171- J�Z J -` I I �% N I I I I REVISIONS C_� U w ¢ Q I II /i I -.. I REV DESCRIPTION DATE APPROVED QI I I I I I \N., I I l i I 1 OEG REVIEW 03/20/19 R. PULIOFF o ,� 0 i I I % I I I \\ I 1 I I I I I NI -. I I DRAWN BY: D. SQUIRES 6I I I PROJECT ENGINEER: B. DUFFEL o , N PROJECT MANAGER: R. PULIOFF 4 _ --LI ---- I JOB NUMBER: 302-FN-H0441 I Jk I _ * gull I -- - - - - ! '' I- I SHOP DRAWING SUBMITTAL DATE: 01/25/2019 ME J - - - - - °- r- -� = T - - - - - - �- .� PLANS a SPEC: DESIGN BUILD: . - - - - - I CONTRACT TYPE: ❑ ■ �� II " PROJECT NAME: JAGUAR LAND ROVER I I I I I I 10125 SW Washington Sq. Rd. Portland, OR 97223 NORTH I I SHEET NAME: F -7 I I I I ! I I I I I PAVIUON - THIRD FLOOR FIRE L.:, J /1j) CENTERM N � ALARM PLAN - (k SOUTH o 0 O O / DRAWING: THIRD FLOOR FIRE ALARM PLAN - SOUTH N W SCALE:118"=1'0" SOUTH FA1 . 3 A 5 0 4' 8' 16' cr Key Plan i rE n w CUSTOMER NAME: OEG Q E F 1709 SE 3rd Ave Portland, OR 97214 I I j • l _ I '/ _MATCHILINE: FA1.3C MATCHILINE: FA1.3BL m. - . _ _ _ •II .- ._MATCHILINE: FA1.3C MATCHILINE: FA1.3B - - II O % Oi / /' nt / , 4., 30 I I r I I TEC - • • ES 7678 SW Mohawk St,Tualatin,OR 97062 I Phone:503-228-8522 Fax:503-228-8521 I I I I I I I 1 I I I I This document and the information/depictions contained/shown is the exclusive property of Convergint Technologies LLC and shall be handled as proprietary and confidential information and 1 I must be returned upon request.This document cannot be I I I reproduced by any means without the written authorization of C7, I I - ~ I _ _ I _ _ _ _ _ I Convergint Technologies LLC. I I GENERAL NOTES: A. ANY & ALL DEVIATIONS FROM THESE PLANS SHALL REQUIRE THE APPROVAL OF A CONVERGINT TECHNOLOGIES PROJECT MANAGER OR I I I SYSTEM DESIGNER. J / I I KEYED NOTES: /! 1. FIELD VERIFY EXACT LOCATION OF STAIRWELL WATERFLOW & TAMPER : / SWITCHES. COORDINATE WITH SPRINKLER CONTRACTOR. j I I I I I / I I I • 18 — — — — 1 . — _ _ _ _ / _ _ _ _ I I I I I O / Oak / I I I / / / - - --- — -- -a- I // / / \ / 'VT / ,..- // 11 - - - - 1 - -- I - --- - - +- - - III I- / \ / \ v �� / N — -- \ Q I I / CC / \ \ \ \ i I Z / \ \ E \ h w \ Z CTD - -;-----_1-=_ _ ; �� yy, --4TJ �- \ �� 527 LEA I --JAI' ^�-..-____ , \ \ �( � // \ ' 1� - II / /, ; J CUSTOMER NAME: OEG 1709 SE 3rd Ave Portland, OR 97214 A G O E F G I�� civ,„ nt I4„, , I I I I I I I I , I • TEC - 1 • • ES 7678 SW Mohawk St,Tualatin,OR 97062 • Fl r, Phone: 503-228-8522 Fax:503-228-8521 0 0 / I II ! it This document and the information/depictions contained/shown � is the exclusive property of Convergint Technologies LLC and I % I i1 I I shall be handled as proprietary and confidential information and I I ! I , , must be returned upon request.This document cannot be / reproduced by any means without the written authorization of / I Convergint Technologies LLC. / I I I GENERAL NOTES: • l I I A. ANY & ALL DEVIATIONS FROM THESE PLANS SHALL REQUIRE THE • I 1 APPSTROVAL OF A EM DESIGNER.ONVERGINT TECHNOLOGIES PROJECT MANAGER OR SY1 r, II Ti KEYED NOTES: I '! i I_ • I — _ ter- ..____. . __..-... — — 1. NOT USED. T 0 I i ! }I i 1 i I , I I i y iI i i I I I I I I I • C - - - - I -! ,_ 1 h- • - - - - ! I I I j i ! j i I I I I . i I I . •i I I I I i i I I I I I II ! i I I i p J I II ; - - - - 4 iE I I Z CCi I I I Z I I I I w L___ I I I Z Z w CC w CC I I r 527 LEA I I I I I RON PULIOFF ! - - - - - - - - - - - - - - - - - - (I - - - - I I I N � e 1 i / WIRE SCHEDULE 4 LETTER TYPE USE I j I // // / A 1 PAIR 16 AWG. TWISTED FPLP DATA LOOP/NETWORK I I I , I \ i B 2 PAIR 20 AWG. RS-232 o -0 n I //,' ,>,/,, \ "i -' - /, I C 1 PAIR 14 AWG. TWISTED FPLP BPS CKT/24VDC wI I \�Nr /% E 1 PAIR 16 AWG. TWISTED FPLP AUDIO CKT o //�vN SEE FA0.1 FOR WIRE SCHEDULE NOTES & GUIDELINES. o I ,� ��� I REVISIONS 0 6 - _ - - I _ _ - _ - - I ���/ - - - - REV DESCRIPTION DATE APPROVED o C I I I 7 ,, ,. 1 OEG REVIEW 03/20/19 R. PUUOFF c, I ! , , L.,,,„.c o I I I , , / I DRAWN BY: D. SQUIRES i I oPROJECT ENGINEER: B. DUFFEL Z r- / PROJECT MANAGER: R. PULIOFF a L ( / / JOB NUMBER: 302-FN-H0441 o i I I I I I w I SHOP DRAWING SUBMITTAL DATE: 01/25/2019 I / I CONTRACT TYPE: PLANS &SPEC:[J DESIGN BUILD: ■ I I / PROJECT NAME: ii - I , - --C - - - 1I - , — — — — O / / JAGUAR LAND ROVER j 10125 SW Washington Sq. Rd. i I Q Portland, OR 97223 NORTH co CO o I ! I I I I ( i SHEET NAME: I M I I PAVILION THIRD FLOOR FIRE ALARM PLAN - oCENTER NORTH I I I I v , MATCHILINE: FA1.3C I _ _ MATCHILINE: FA1.3C — — _ _ _ _ MATCHILINE: FA1.3B- 71olm-- ., /MATCHL : . — DRAWING: N THIRD FLOOR FIRE ALARM PLAN - NORTHLu SOUTH (1D FA1 . 3C 5 SCALE:1/8"=1'-0" 0 Ln Key Plan z 0 4' 8' 16' 0 W CUSTOMER NAME: OEG 1709 SE 3rd Ave Portland, OR 97214 '�r Co ' r' fl f TEC - te • ES 7678 SW Mohawk St,Tualatin,OR 97062 Phone:503-228-8522 Fax:503-228-8521 • This document and the information/depictions contained/shown is the exclusive property of Convergint Technologies LLC and shall be handled as proprietary and confidential information and must be returned upon request.This document cannot be reproduced by any means without the written authorization of Convergint Technologies LLC. THIRD FLOOR (BY OTHERS) (1) (1) (3) (3) A 120VAC El— 113P52 JANITOR 205 0 Q I A-7 C (7) (2) w b ® BPS2-03 47K z SECOND FLOOR C) cp (2) (3) (1) A ❑M GSM — - w —•—•---Q ----• ® '—•—-�-—----—--•�FACP� � 120VAC_ 1 (BY OTHERS) w (BY OTHERS) I F?S1 CC o _LECTRICAL ROOM 160 AECHANICAL 199 MEZZANINE — — — — — — - - - - - - - - - - - - - ) 527 LEA p1"�f BPSt-02 47KRON PULIOFF j A.B� C 7 (2) C) (2) (2) (2) (2) (2) (2) (1) (2) (2) JA o �4 (��w 47KBPS1-01 Z ` ELEVATORYCONTROL 47K2-04 (TYP. OF 2) N b AG. 47K2 -02 WIRE SCHEDULE _ _ (0) LETTER TYPE USE BPS2-01 co �� ��� 47K A 1 PAIR 16 AWG. TWISTED FPLP DATA LOOP/NETWORK B 2 PAIR 20 AWG. RS-232 ANN C 1 PAIR 14 AWG. TWISTED FPLP BPS CKT/24VDC w E 1 PAIR 16 AWG. TWISTED FPLP AUDIO CKT o VESTIBULE 101 N SEE FA0.1 FOR WIRE SCHEDULE NOTES & GUIDEIINES. FIRST FLOOR W REVISIONS REV DESCRIPTION DATE APPROVED co 0 1 OEG REVIEW 03/20/19 R. PUUOFF 0 it FIRE ALARM RISER DIAGRAM SCALE:NTS DRAWN BY: D. SQUIRES PROJECT ENGINEER: B. DUFFEL z Q _ PROJECT MANAGER: R. PULIOFF o JOB NUMBER: 302-FN-H0441 J w SHOP DRAWING SUBMITTAL DATE: 01/25/2019 CONTRACT TYPE: PLANS& SPEC:0 DESIGN BUILD: ■ PROJECT NAME: JAGUAR LAND ROVER 10125 SW Washington Sq. Rd. Portland, OR 97223 co SHEET NAME: 0 N coN FIRE ALARM RISER C) DIAGRAM 0 J DRAWING: C) w U- 5 FA2 • 1C C) z C) C 0 U- w N C) CUSTOMER NAME: OEG 1709 SE 3rd Ave Portland, OR 97214 GO, �r ,,,,,e, nt TEC - ie . ES 7678 SW Mohawk St,Tualatin,OR 97062 Phone:503-228-8522 Fax:503-228-8521 This document and the information/depictions contained/shown is the exclusive property of Convergint Technologies LLC and shall be handled as proprietary and confidential information and must be returned upon request.This document cannot be • reproduced by any means without the written authorization of Convergint Technologies LLC. r )TELCO CABLE TO CELLULAR COMMUNICATOR <_r TELCO CABLE (BY CONVERGINT) I ILINE � 6"---77-) r \J ! I( n ` 1NII 1 9 OO TOOGO � - I DEDICATED n O . _ • CIRCUIT (BY OTHERS) NEUTRAL �. (RE) ) - J 011 64 111 al hod Li (�J moi, ,; L ., )he I II 1 F l /l F T � JI Ji e ( J TO INITIATION DEVICES / k, u \\, r /MN_� paw •-• i. V SLP O.1 IAC POWER C I. �-, _ -N. I 1 iii 0 Power u M• I TROUBLE 01 DISABLE (XOISAB /GYJPANEL 0 FYe Alarm g�,cE I 0 &garvYory p moce 09 1 TEST ®I 0 Ground Fant Gft I" SERNCE pp `‘ o ibx,bl. ' —Ili FAIAT ) DETECTOR ®J SIGNAL i ;�re, l SILENCE GY I nCIpla Ej�led . l"T -ui ` / 1Adrlslrro. -) fU' (------,,, - -—,-,-„.--. -,1 L CI mo.......... 1 T L ODril /. NAC1 CIRCUIT o ��t 00 ® l ll 1 1.•i .Lamp Teat rfi I `' I t,;I; e L...¢ 0 I lel' w„ ® I ,!*)!1(.-7,,)% NAC2 CIRCUR . dip. p rw - 9 wxr� LIEF,--_ k TiVai•m \C•il'F�� �/ 1� cn `^" n (fi/ _kkryry t 1 i t Or I(� O���y I li '�' (Ui cnP d - - -- � - ------ �_�l I 'I - - - - - -- - _ - - l f 1 1 i 1! i1 I I -r ' f u n II I� CD AR 1 I ',_ CII !I 44 I et. Fire Alarm System Battery Calculation Form _ rr ���r jn m� _ ;fir:i-7„T-„.F.,--.71, 1 ,.-k I I� IE� 5 �J( r= 11, ; ��i LI {^✓ I -�-___ -f �I' '� i 'I System voltage(Vdc): 24 Project name:Jaguar Land Rover CTD z TRANSFORMER n �_ :._ Ij,I I j � Supervisory Hours: 24 Project number:302FNI-0441 ���ffJ I I w O II` 1� 0 ;I ABEAM II Alarm Minutes: 5 Panel type: 1064 w %Extra Battery Capacity: 20% Panel Location:Bectrical Room 160 Power Supply ID:I FACP z ;I —I¢ 0 0 3 li rn AH requiredAHrequired-Alarm:I 0.05 pervisory:1 8.71 + Commenta 527 LEA aery■ II 0 0 II ye' (((--,C- 1'/ L I (*.Maur Q 0 m II F� Total AH required(with%):I 10 51 RON POLI FF aapaa Q 0 m II i Q o m 3 o "DIM Battery AH provided:I 12 I - .-7-1- (2) 0 II c 5N7)art 0 m 71 ■ ! T o 0 Z 'I 7X FIX w ii u_ j .-. O Line Identification Quantity Supervisory rrLA Alarm mA Total Sup.Illine Total Ala.Mine CD .X� 1°64;° 155.000 204000 155 204.000 WIRE SCHEDULE ro 2 Loop1:Internal 1 55 000 125.000 55.000 125.000 z `I 3 RLC&C 1 99000 115-000 99.000 115.000 LEITER TYPE USE L_ 'iCO 4 SA-232 1 13 000 20.000 13.000 20.000 A 1 PAIR 16 AWG. TWISTED FPLP DATA LOOP/NETWORK o5 SA-QCT 1 41000 100.000 41.000 100.000 RS- 232 0.000 0.000 C 1 PAIR 14 AWG. TWISTED FPLP BP52CKi/24VDC F- icn ; T 0000 0.000 E 1 PAIR 16 AWG. TWISTED FPLP AUDIO CKT o -+ —J �- — i ( 19 FACRO1 1 0.000 0.000 0.000 r: 20 FACR02 1 0-000 0000 0.000 m BATTERY BATTERY O SEE FA0.1 FOR WIRE SCHEDULE NOTES & GUIDEUNES. o SEE CALCULATIONS SEE CALCULATIONS Farm da.(((SgNFgpw wrvicnrymA*SiSiip rvisrxyH twc)+(Alarmm 'Alarmitec))`6rtrarapacity)=Tata!AHreatl REVISIONS TABLE FOR SIZE TABLE FOR SIZE o General Note:FACP current draws are reflected in their'worst case scenario.Current draws have been REV DESCRIPTION DATE APPROVED m taken from the UL approved installation guide 1 OEG REVIEW 03/20/19 R. PUEJOFF - Total Supervisory mA:l 363.00 �i 11 0 Total Alarm mA:I 564.00 z I- CD DRAWN BY: D. SQUIRES o PROJECT ENGINEER: B. DUFFEL o PROJECT MANAGER: R. PUL!OFF a o JOB NUMBER: 302-FN-H0441 0 w - SHOP DRAWING SUBMITTAL DATE: 01/25/2019 CONTRACT TYPE: PLANS & SPEC:[J DESIGN BUILD: ■ PROJECT NAME: 1064 FIRE ALARM CONTROL PANEL DETAIL .0 1064 FIRE ALARM CONTROL PANEL BATTERY CALCULATIONS JAGUAR LAND ROVER SCALE:NTS SCALE:NTS 10125 SW Washington Sq. Rd. Portland, OR 97223 1--- CO SHEET NAME: O CA CO CV FIRE ALARM CONTROL 62, - PANEL WIRING DETAIL & BATTERY CALCULATIONS J d DRAWING: . FA3 . 1 x3 up,_cn L Lu • cn - J CUSTOMER NAME: OEG 1709 SE 3rd Ave . Portland, OR 97214 1.7l BOOSTER POWER SUPPLY BATTERY CALCULATION SHEET BOOSTER POWER SUPPLY BATTERY CALCULATION SHEET CO J //c j#' Panel LocatioriMechanical 199 Panel LocatiortlJanitor 205 o Panel MFR JEST Panel MFR JEST Panel Model# BPS10A Voltage: Vdc Panel Model# BPS10A Voltage:Vdc TEC - fe • ES Derating 201%(A) Derating 20%(A) V-Drop Max: 3.10 vdc Starting NAC Voltage:I 19.11Vdc V-Drop Max: 3.10 vdc Starting NAC Voltage:! 19.111Vdc BPS1 I BPS2 7678 SW Mohawk St,Tualatin,OR 97062 CIRCUIT# TYPE DH? CIRCUIT NAME SUP ALRM CIRCUIT# TYPE DH? CIRCUIT NAME SUP ALRM Phone:503-228-8522 Fax:503-228-8521 AuxlNac YeslNo (mA) (mA) Aux/Nac Yes/No (mA) (mA) . 1 NAC BPS1-01 0 1756 1 NAC BPS2-01 0 2008 1 3.0000 =• 2 NAC BPS1-02 0 1383 2 NAC BPS2-02 0 2551 This document and the information/depictions contained/shown 3 NAC BPS1-03 0 0 3 NAC BPS2-03 0 1896 is the exclusive property of Convergint Technologies LLC and SIGA-CC1S TO BE MOUNTED INSIDE I 4 NAC BPS1-04 0 0 4 NAC BPS2-04 0 1000 shall be handled as proprietary and confidential information and BPSxA CABINET. SEE INSTALLATION Aux Aux Voltage at Device Aux 0 0 Aux Aux Voltage at Device 1 Aux 0 0 MANUAL FOR MOUNTING INFORMATION. 11 II VI must be returned upon request.This document cannot be IICb Spare 20% 627.8 I Spare 20% 1491 � Totals 0 3766 8 1 Totals 0 8946 reproduced by any means without the written authorization of 10 9 Convergint Technologies LLC. V ' #of Aux Circu'r 0 x35mA' 0 mA(B) #of Aux Circut 0 x35mA* 0 mA(B) I. PERSONALITY CODE 25 Total Sup Current 0 mA(C) Total Sup Current 0 mA(C) S• •SIGAGGIS Rated Base BPS Sup. 70 mA(D) POWER SUPPLY NOTES: Rated Base BPS Sup. 70 mA(D) POWER SUPPLY NOTES: 0 © Total Sup.mA(B+C+D) 70 mA**(E) •Door holder current draw not Total Sup.m.,(B+C+D) 70 mA"(E) •Door holder current draw not Hours of Supervisory] 24IHrs(F) calculated for battery backup.AUX Hours of Supervisory! 241Hrs(F) calculated for battery backup.AUX 8 7 6 5 4 3 2 1 Supervisory mAh(E*F) 1680 mAh(G) power output to be programmed Supervisory mAh(OF) 1680 mAh(G) poweroutputto be programmed • w, • j BPS2-01 J ®® � 1 II1� k� Total NAC Current 3766.8 mA(H) to drop on AC Loss(Fail Safe) O to drop on AC Loss(Fail Safe) BFSXA J BPS2-02 •20%spare capacity has been Total NAC Current 8946 mA H •20%spare capacity has been Rated Base BPS AlArm 270 mA(J) automaticallycalculatedintothe Rated Base BPS AlArm 270 mA(J) Total Alarm mA(B+H+J) 4036.8 mA(K) Total Alarm mA(B+H+J) 9216 mA(K) automatically calculated intothe • BPS2-03 totalpowersupplyloadinalarm. totalpowersupplyloadinalarm. ( Minutes of Alarm 5 min(L) Minutes of Alarm 5 min(L) DATA IN DATA OUT Hours of Alarm(1160) 0.08 Hrs(M) *Future expansion&tenant ( (M) •Future expansion&tenant •... t 1 SPARE Hours of Alarm 1160) 0.08 Hrs Alarm mAh Req. (K'M) 336 mAh{N) improvements may surpass Alarm mAh Req.(K"M) 768 mAh(N) improvements may surpass REFER TO INSTALLATION MANUAL FOR JUMPER AND DIPoriginal20%sparecapcacityrating. SWITCH SETTINGS. Total mAh Req.(G+N) 2016 mAh(0) origina120%sparecapcacitYrating. Total mAh Req.(G+N) 2448 mAh(0) _ 1;;,,•,. Total Ah Req.(0/1000)*P, 2.42 Ah ' Total Ah Req.(O/1000)*PJ 2.94 Ah I . (3 P=1+(A/100) P=1+(A/100) OM co Battery Size Provided, 8 Ah I Battery Size Provided, 8 Ah I •• da1147K Cs VOLTAGE DROP CALCULATIONS BPS1 VOLTAGE DROP CALCULATIONS BPS2 -• d C. Circuit Alarm Resistance! Circuit Voltage Circuit Alarm Resistance! Circuit Voltage •• c, Length Sup.Current Current Wire Gauge 1000ft Resistance Drop Length Sup.Current Current Wire Gauge 1000ft Resistance Drop . C. Circuit Name (ft) (A) (A) (awg) (ohms) (ohms) (V) Circuit Name (ft) (A) (A) (awg) (ohms) (ohms) (V) • • ••M• ON i, BPS1-01 287 0 1.756 14 3.07 1.762794 1.786 BPS2-01 289 0 2.008 14 3.07 1.776302 2.283 BPS1-02 297 0 1.383 14 3.07 1.82358 1.655 BPS2-02 316 0 2.551 14 3.07 1.94024 2.987 `'_`'s ..,,,,,.„ ,••� O� BPS1-03 0 0 0 14 3.07 I 0 0.000 BPS2 03 193 0 1.896 14 3.07 1.18502 1.202 BPS1-04 0 0 0 14 3.07 10 0.000 I BPS2-04 192 0 1 14 3.07 1.17888 0.867 Aux 0 0 0 16 4.99 0 0.000 ! Aux 0 0 0 16 4.99 0 0.000 POINT-Td-POINT(.i C TSR &K9QW)1 BPS1-01 / bPS1-02 BPS2-01 BPS2-02 DeviceDistance to - !Voltage Device !Distance to I 'Voltage at Device Distance to Voltage at Device 'Distance to IVottage at 1 7.0000 ROUTE AC SUPPLY THROUGH THESE • Number (Device Device Current !Device Number !Device ,Device Current {Device Number Device Device Current Device Number Device Device Current Device KNOCKOUTS ONLY BPS1-01-01 60 0.19 18. BPS1-02-0179 0.1471 18.43 BPS2-01-01 100 0.316 17.87 BPS2-02-01 35 0.19i 18.55 120VAC DEDICATED / / / BPS1-01-02 30? 0.316 18.1 BPS1-02-02 1 30• 0.2811 18.20 BPS2-01-02 31 0.316 17.55 BPS2-02-02 30 0.147! 18.12 (NON-POWER LIMITED)CIRCUIT (BY OTHERS) BPS1-01-03 44, 0.147 17. BPS1-02-03 1 701 0.337 17.79 BPS2-01-03 31 0.316 17.28 BPS2-02-03 301 0.19 17.71 o BPS1-01-04 8 0.151 17. BPS1-02-04 591 0.281 17.57 1BPS2-01-04 39 0.316 17.03 BPS2-02-04 40 0.191 17.21 BPS1-01-05 30 0.19 17. BPS1-02-05 591 0.337 17.45 1BPS2-01-05 31 0.372 16.89 BPS2-02-05 25 0.316 16.93 N BPS1-01-06 23_ 0.109 17.4'Q BPS1-02-06 Oj 0 16PS2-01-06 31 0.372 16.82 BPS2-02-06 25 0.316 16.70 i,-3 _ BPS1-01-07 23= 0.147 17. 0 BPS1-02-07 0 0 BPS2-01-07 0 0 BPS2-02-07 30 0.1916.48 / BPS1-01-08 17i0.316j 17.44 BPS1-02-08 01 0 1 BPS2-01-08 0 0 8P52-02-08 16 0.19 16.38 - BPS1-01-09 261 0.191 17.3 BPS1-02-09 0 0BPS2-01-09 0 0 BPS2-02-09 30 0.316 16.23 i BPS1-01-10 1 0 0; BPS1-02-10 01 0 BPS2-01-10 01 01 8PS2-02-10 25 0.316 16.15 n cp z BPS1-01-11 ! 0 Oj BPS1-02-11 01 0 BPS2-01-11 0 01 BPS2-02-11 30 0.19 16.11 z BPS1-01-12 ! 0 01 BPS1-02-12 01 Oi BPS2-01-12 0 0 BPS2-02-12 0 0 o BATTERY WIRING BPS1-01-13 ' 0' OI BPS1-02-13 0 01 BPS2-01-13 _0 0 BPS2-02-13 0 0. BPS1-01-14 0, 0 BPS1-02-14 ! 04 0 1BPS2-01-14 0 0 BPS2-02-14 0 01 )) z (NON-POWER LIMITED) BPS1-01-15 01 0 BPS1-02-15 I 01i 0 1BPS2-01-15 0 0 BPS2-02-15 0 0 i \ \ BPS1-01-16 0- 0 BPS1-02-16 1 01 01 1BPS2-01-16 0 0 BPS2-02-16 01 0 z I 1BPS1-01-17 0 0 BPS1-02-17 ° 0 01 BPS2-01-17 0 0 BPS2-02-17 0 0 z 1 I BPS1-01-18 0 0 BPS1-02-18 1 0z13 01 BPS2-01-18 01 0 BPS2-02-18 0 0 BPS1-01-19 0 01 BPS1-02-19 DI 01 BPS2-01-19 0 0 BPS2-02-19 0 01 BPS1-01-20 01O1 BPS1-02-20 I 0. 01 BPS2 -01-20 0 0 BPS2-02-20 0 OI o I BPS1-03 ) -"• BPS -03 BOS2-04 527 L z EA Device !Distance to Voltage at Device !Distance to Voltage at Device Distance to Voltage at Device Distance to Voltage at BATTERY Number Device ,Deuce Current Device Number !Device !Device Current Deuce Number Device Device Current Device Number Device Device Current 'Device RON PU LIOFF BATTERY BP51-03-01 0 0 BP51-04-01 j 01 01 (8PS2-03-01 27 0.147 18.79 BPS2-04-01 120 0.372' 18.36 Q BPS1-03-02 0, 01 BPS1-04-02 01 0 BPS2-03-02 13 0.316 18.65 BPS2-04-02 17 0.3721 18.30 BPS1-03-03 0 0 BPS1-04-03 01 0 BPS2-03-03 22 0.19118.45 BPS2-04-03 22 0.1091 18.26 BPS1-03-04 0' 0 BPS1-04-04 0' 0 BPS2-03-04 13 0.109 18.35 BPS2-04-04 33 0.1471 18.23 = BPS1-03-05 0. 0 BPS1-04-05 010 BPS2-03-05 13 0.1091 18.26 BPS2-04-05 0 01 z BPS1-03-06 Q 0 BPS1-04-06 01 61BPS2-03-06 14 . 0.19 18.17 BPS2-04-06 0 01 N BPS1-03-07 01 01 BPS1-04-07 0 0BPS2-03-07 27 0.372 18.04 BPS2-04-07 0 01ro- WIRE SCHEDULE BPS1-03-08 0 01 BPS1-04-08 0 01 BPS2-03-08 16 0.147 17.99 BPS2-04-08 0 OI ! BPS1-03-09 I 0= 01 BPS1-04-09 01 0! BPS2-03-09 48 0.316 17.90 BPS2-04-09 0 0' USE BPS1-03-10 I 0- 0 BPS1-04-10I 0' 0' IBPs2-03-10 0 0 BPS2-04-10 0 0iAWG. TWISTED FPLP LOOP/NETWORK LLI1tN o% BPS1-03-11 0 ---- - 0 BPS1-04-11 0 0 _ A 1 PAIR 16 DATA LOOP N !BPS2-03 11 0 0 BPS2 04 11 0 0 B 2 PAIR 20 AWG. RS 232 o BPS1-03-12 0 OI BP-S1-04-12_1 0� 0 !BPS2-03 12 0 01 BPS2 0412 0 0 C 1 PAIR 14 AWG. TWISTED FPLP BPS CKT/24VDC N � BPS1-03-13 i 0 0 BPS1-04-13 0, 0 !BPS2-0313 0 0 BPS2-04-13 0 0, Lai BPS1-03-14 0_- 0 BPS1-04-14 I 0' 0 BPS2-03-14 0 0 BPS2-04-14 01 0' E 1 PAIR 16 AWG. TWISTED FPLP AUDIO CKT o BPS1-03-15 0 of BPS1-04-150 0, BPS2-03-15 0 0 BPS2-04-15 0 0 BPS1-0316 01 OI BPS1 0416 ! 0 01 BPS2-03-16 0 0 BPS2-04-16 01 0 SEE FAO.1 FOR WIRE SCHEDULE NOTES & GUIDELINES. u" BPS1-03-17 01 01 BPS1-04-17 i 01 0, BPS2-03-17 0 0 BPS2-04-17 0 0 moBPS1-0318 0t 0 BPS1-0418 0' o BPS2-0318 0 0 BPS2-0418 0 0 REVISIONS o BPS1-03-19 0= 0 BPS1-04-19 I 01 0 BPS2-03-19 0 0 BPS2-04-19 0 0 oBPS1-03-20 0= 0 BPS1-04-20 ! 01 0 BPS2-03-20 0 0 BPS2-04-20 0 0 REV DESCRIPTION DATE APPROVED o I . 1 I I I 1 OEG REVIEW 03/20/19 R. PUUOFF co Q 0 I 0 z J o DRAWN BY: D. SQUIRES i o PROJECT ENGINEER: B. DUFFEL Z TYPICAL BOOSTER POWER SUPPLY PANEL DETAIL BOOSTER POWER SUPPLY VOLTAGE DROP CALCULATIONSPROJECT MANAGER: R. PULIOFF o SCALE:NTS JOB NUMBER: 302-FN-H0441 SCALE:NTS SHOP DRAWING SUBMITTAL DATE: 01/25/2019 CONTRACT TYPE: PLANS & SPEC:❑ DESIGN BUILD: ■ PROJECT NAME: JAGUAR LAND ROVER 10125 SW Washington Sq. Rd. Portland, OR 97223 Q SHEET NAME: O co BOOSTER POWER SUPPLY N w DETAILS & VOLTAGE 0 DROP CALCULATIONS J d • DRAWING: W FA3 . 2 C 5 C) C) z . ,,C) 0 , Lu CUSTOMER NAME: I TERM DESCRIPTION 1 NOT USED DATA IN FROM SIGNATURE DATA IN FROM SIGNATURE 2 DATA IN/OUT (+) CONTROLLER OR PREVIOUS CONTROLLER OR PREVIOUS OEG • 3 RNOT USEDED DEVICE DEVICE 4 DATA IN (-) (-)(+) (-)(+) 1709 SE 3rd Ave 47K EOL 5 REMOTE LED 1/ \I 6O O O „ `/ 0 O 0RD Portland, OR 97214 TYPICAL N.O. - �� 7 6 NOT USED 0 I II O 0 II INITIATING DEVICE MOUNT IN �C+'�i / 7 DATA OUT (-)\ , L _ . -pal 3-OCT. BOX \ :` i _.�► "k;II II NC2 I NC2; —r . , 7 cst \�011, c) � III = C2 _ C2 I �j. 0 O O �' fia111 NO2 9 NO2':. 9 ' _ .� ` I 111 NC1 9 1 �' NC1 E 9 ;', CO ,r, j Fit SINGLE SIGACT INPUT MODULE `\ \ I ..I I �i'' '=,� ici ® C1 _ TEC - C C c e 0 o \coA • . ! NO1_,® I NO1 ® ! L C - • L V r* >< II 0I 11 o O0 4 3 2 — 7678 SW Mohawk St,Tualatin,OR 97062 0Phone:503-228-8522 Fax:503-228-8521 STAND ARD ASE O ° O (+) 0 O 0 6) —(+) i" I" 7 7 I SIGA-S I y yQ ,20VAC y y ,20VAC • (-)(+) (-)(+) This document and the information/depictions contained/shown DATA IN (+)> 1 I >DATA OUT (+) DATA IN (-) Y —IS- DATA OUT (-) TO NEXT DEVICE TO NEXT DEVICE ise p DATA IN (-) 111 a DATA OUT (-) DATA IN (+) > the exclusive property 1> DATA OUT (+) p p rty of Convergint Technologies LLC and FROM SIGNATURE TO NEXT DEVICE FROM SIGNATURE TO NEXT DEVICE • shall be handled as proprietary and confidential information and CONTROLLER OR CONTROLLER OR - must be returned upon request.This document cannot be PREVIOUS DEVICE PREVIOUS DEVICE 12OVAC DAMPER 12OVAC SHUNT I reproduced by any means without the written authorization of CONTROL CIRCUIT TRIP CIRCUIT Convergint Technologies LLC. SINGLE INPUT MONITOR MODULE0 SMOKE & HEAT DETECTOR BASE FSD CIRCUIT SHUTDOWN 4 SHUNT cTRIP GENERAL NOTES: SCALE:NOT TO SCALE SCALE:NOT TO SCALE SCALE:NOT TO SCALE A. WIRING DETAILS ARE TYPICAL NOT ALL DEVICES SHOWN MAY APPLY TO THIS PROJECT. ' I - I B. DEVICE T-TAPS TO BE MADE ON OUTBOUND TERMINALS rq 47K EOL DATA IN FROM SIGNATURE 24V DC FROM FACP (+) KEYED NOTES: ALARM CONTROLLER OR PREVIOUS PANEL/POWER SUPPLY (-) TYPICAL N.O. INITIATING DEVICEDEVICE 1. NOT USED. s DATA OUT (-) } TO NEXT (INPUT 1) TEST s DATA OUT (+) DEVICE (-)(+) 0 STATION �10jy101 + I0 0 0 \/ \/ d Q0 -31iq 47K EOL i a DATA IN (-) FROM SIGNATURE T� I I i AUXILIARY ( ) 1 CONTROLLER OR CEJ ��� IOa DATA IN + PREVIOUS DEVICE K EOLR II TYPICAL N.O. INITIATING DEVICE v v o v v o •® ® ® � , , (INPUT 2) DEVICES- z z z z I IID 13 I 8 7 L JNC2I O O O _1 C2 L I II 0 �O 0 111 I I I (�- ry r SINGLE INPUT MODULE 11 �'I —' NO2I 9 ' 1111 1 1 SIGACTI AI i-' ® esee�aa_ ® I 111 SDUAL IGH-NPUT MODULE nisi^ uX313 it i6s 11 —lj C11' e e El ® © 161 KliC 0 4 3 2 1 RI , v v N No1 �@ `1 0 Ts , I 0 O u 4 3 2 , �'�� I L®] LJ ° Q 0 ° 0 C) 0 T I DATA IN (+)> I 1 L-1 a DATA OUT (+) 1 V DATA IN (-)> III • ® 0 0 0 0 � a DATA OUT (-) (-)(+) DATA IN (+)---- a DATA OUT (+) 0 FROM SIGNATURE TO NEXT DEVICE TO NEXT DEVICE ii--- o DATA IN (-):---- a DATA OUT (-) . CONTROLLER OR PREVIOUS DEVICE FROM SIGNATURE TO NEXT DEVICE SHUNT TRIP CIRCUIT MAGNETIC DOOR "' CONTROLLER OR Lc PREVIOUS DEVICE HOLDERS E .-(E___ N 0 DUAL INPUT MONITOR MODULE DUCT SMOKE DETECTOR SHUNT POWER MONITOR DOOR HOLDER RELEASE SCALE:NOT TO SCALE 6 SCALE:NOT TO SCALE SCALE:NOT TO SCALE 8 SCALE:NOT TO SCALE Lr0 i cpU w . z ..__I-L- F-1 I-U-1 , - CD 0i MOUNT IN 4" l__L..� =Lc, = SQUARE BOX O O ., i. 0c, ® ® ® ® ® ® ° 0 _ ' '� • �' . 527 LEA SPKR C S+ S- O N o o L 0 X111 Mg 1� I C WO°1°1 RON PULIOFF _ z v z z v z FACTORY CONNECTIONS I iI Li DO NOT ALTER 8 7 , " " AI -- �P' 0 0 0 I S+ S- 0 I /y i 0 MANUAL PULL STATION O TT//II SIGH-270 1111 j ra E • I I�IIIII�h�NVVVI�II�I■�■�■, N ass FROM BPS OR 7--- PREVIOUS a TO NEXT DEVICEq P WIRE SCHEDULE 0>-, O � � O 0 I®®®SII FROM DEVICE > a OR EOL LETTER TYPE USE 0o A 1 PAIR 16 AWG. TWISTED FPLP DATA LOOP/NETWORK 0 C E) OFROM BPS OR > - - - a TO NEXT DEVICE B 2 PAIR 20 AWG. RS-232 ID (1 PREVIOUS DEVICE ; - a OR EOL C 1 PAIR 14 AWG. TWISTED FPLP BPS CKT/24VDC w 0 E 1 PAIR 16 AWG. TWISTED FPLP AUDIO CKT O O O . i ) SEE FA0.1 FOR WIRE SCHEDULE NOTES & GUIDELINES. II ' I IIII 1 f . I J L REVISIONS o DATA IN (+) - a DATA OUT (+) j DATA IN (+) - 0.-DATA OUT (+) O J I_ - REV DESCRIPTION DATE APPROVED co o FROM DATA OUT (-) DATA IN (-) P.- 1 OEG REVIEW 03/20/19 R. PUUOFF DATA OUT (-) i PREVIOUS ADEVICE >.- 1 L -s-OTO NEXR EOLT DEVICE DATA IN (-) TO NEXT DEVICE FROM SIGNATURE TO NEXT DEVICE - FROM SIGNATURE o CONTROLLER OR o CONTROLLER OR PREVIOUS PREVIOUS DEVICE DEVICE CONTROLLABLE RELAY MODULE MANUAL PULL STATION TYPICAL STROBE & HORN/STROBE TYPICAL SPEAKER/STROBE 6 " 1 SCALE:NOT TO SCALE • O SCALE:NOT TO SCALE SCALE:NOT TO SCALE SCALE:NOT TO SCALE DRAWN BY: D. SQUIRES PROJECT ENGINEER: B. DUFFEL Z 1 f -- - � - - - - - -- - PROJECT MANAGER: R. PULIOFF o I NOTES: - 24" MIN ACCESSIBLE BEDROOM STROBE JOB NUMBER: 3O2-FN-H0441 1. DIMENSIONS FOR DETECTOR SPACING ARE TO CLOSEST EDGE OF DETECTOR. 2. DETAIL DEPICTS DEVICE TYPES ONLY, NOT SPECIFIC MODEL. A/C SUPPLY SHOP DRAWING SUBMITTAL DATE: 01/25/2019 j 3. DIMENSIONS ARE BASED ON NFPA 72, 2013 EDITION. _II I DIFFUSER 3' (MIN) -191 I1 FLUORESCENT CONTRACT TYPE: PLANS & SPEC:EI DESIGN BUILD: ■ CEILING LIGHT 4" r//////////////////// /////////////////////,///// //// /////////<1ffi\\\\7/////. //////////// /�y///////// /J PROJECT NAME: SYNCHRONIZED MORE THAN .i TWO ANY FIELDUAL I OF APPLIANCES \\ CEILING MOUNTED 3' MIN _ _ —.I � � JAGUAR LAND ROVER SMOKE/HEAT DETECTOR / AUDIO/VISUALMAX 10125 SW Washington Sq. Rd. & VISUAL ___ y - 6" / ONLY DEVICES Ma ..,•- 5' / Portland, OR 97223 DOOR WIDTH LESS 3 lE)- CONTROL PANEL 1 SHEET NAME: f c REMOTE 7 " MAGNETIC wANNUNCIATOR or DOOR HOLDER I // TYPICAL WIRING OF FIRE Q POWER SUPPLY / 80" MIN !� I 3 ; ALARM FIELD DEVICES 72" AFF 96" MAX [:1 I II o / TOP OF 0 z / CABINET FIRE PHONE z / 60" AFF (MAX) JACK / TOP OF / DRAWING: CABINET MANUAL - STATION 42"MIN/48" MAX PULL / w FINISHED FLOOR 1 / FA 3 ■ 3 5 UD cn Z.) RESERVED TYPICAL MOUNTING HEIGHTS DETAIL SCALE:NOT TO SCALE SCALE:NOT TO SCALE w , N 2 120VAC CUSTOMER NAME: - PRIMARY ALTERNATE SHUNT SHUNT (+) I 1 (-) I RED HAT RECALL RECALL POWER (NO) (NO) (NO) /47K TRIP i OEG (COM) (COM) —► (CUM) SPARE (COM) 1709 SE 3rd Ave r... (NC) (NC) (NC) Ft 47K ' (NC) Portland, OR 97214 1 2 3 4 1 2 3 4 1 : 3 4 1 2 3 4 1 4 3 4 1 2 3 4 0106 TB1 OdDItil i ®IW TB2 plabillal TB3 itititil TB4 ritidDiall TB5 1111:DI®F TB6 / rel 0 .. I i . ---- DATA IN �� Ov p O�� p $ 4 N .� .� Gor /� n o (-) (+) T87 O �1 O �I 0 �1 0 awl O I e 3 ��Ij ��II ��w11 ® 2 Al 1 a4 a1 © 3 U ./ �rn (.1)(.1) N rnrn V)(11 TEC-14 / S 0' ZZ ZZ CLZZ h— ZZ ZZ • 2 gg gg gg gg gg TB15 1 a_0_ , d0_ I rlr- I dw I do QI w w = Q w w = a w w =- Q w w = Q w w 4 7678 S W Mohawk St,Tualatin,OR 97062 (+) (—) W W r W W '3 ( u W r W W W W ® 3 O C7 C7 O C7 C a . 7)_1-1 N 3 (.7_2_1-0_,L0_ r, r, N r, r, r, �1 Phone:503-228-8522 Fax:503-228-8521 DATA OUT C ® 1 I®0I0 I®0 01 L____�_ �' �_ �®t_ _FEL_ \, ;/ This document and the information/depictions contained/shown is the exclusive property of Convergint Technologies LLC and Ishall be handled as proprietary and confidential information and n 0 Power 1) must be returned upon request.This document cannot be O Fire Alarm reproduced by any means without the written authorization of 120VAC SHUNT 0 Supervisory Convergint Technologies LLC. TRIP CIRCUIT 0 Ground Fault O Trouble GENERAL NOTES: 0THISELEVATOR RECALL WIRING DETAIL - MFCEV 0 Controls Enabled SCALE:NOT TO SCALE d 0 Ack/Sllence A. WIRING DETAILS ARE TYPICAL NOT ALL DEVICES SHOWN MAY APPLY TO PROJECT. 0 Reset B. DEVICE T-TAPS TO BE MADE ON OUTBOUND TERMINALS ® ® N O Signal Silence KEYED NOTES: ell, 1:71 1. NOT USED. I (1)) O Drill [ 0LamPTest j A 4 ANTENNA O \.1\ . I I BATTERY SIZING CALCULATIONS CELLULAR COMMUNICATOR ' Panel Name: TG7 II RBRRHURR Requirement for standby current: 24 hrs. Design Superrison Current=r 0.67 amp-hr I I 120VAC BY- 0 0 CD Requirement for alarm current: 5 min. Design Alarm Current=r 0.01 amp-hr OTHERS — < Spar:Battery Capacity: 20 % Additional Capacity Current=r 0.14 amp-hr EDWARDS 596 0 FROM FACP OR ( OII1(r)N d 0 0 A- u_ MIN.BATTERY SIZE REQ'D=r 0.82 amp-hr TRANSFORMER 0 PREV. RLCD l g11(-)II r� 0 0 X11 () 8 ,5. o111(r)OUr IL 0 0 I] (+) ❑ I TO NEXT RLCD our IL 0 0 II we i BATTERY SIZE PROVIDED= 3 AH ❑ OINK()+ N vc) C' PANEL EQUIPMENT (+) z 0 a Standby Alarm TOTAL TOTAL STATUS LEDs CH2(-)N Q 0 @ I] v(.) o (ma) (ma) (ma) (ma) / (+) Q m (� �] F 0� Quantity Derive Curent Curets Standby Current Alarm Current 0 0 - (-)OUT II E I TELGUARDTGLAFO2 28 117 28 117 h FROM FACP OR :sv(r)n IL m 0 II D - OUT z 0 0 0 PREY. RLCD ( 244/0' II m 0 Il c z 0 0 `` PANEL TOTALS 2s 117 LED TO NEXT RLCD OR EOL ( (+)our -IL m B / MODE 244/0 OUT ir_o 0,al rr I >o 0 0 Standby Alarm � o / GRAND TOTALS(field&panel) I 28 I 117 INTERNAL BATTERY TX RX 527 LEA a Formula:_ - [(A+B)x C]+[(D+E)x F]x G-Minimum Amp-Flour Battery Capacity— —j 0 I ® O ® RON PULIOFF o TELCO CABLE TOS Where: A=htemal panel standby current{arcps}. 3 7 9=External device standby current{amps}. FRE ALARM PANEL o_ C=Duration panel must remain operational(hours). D=Internal alarm current{amps}. ' 1 z 'y E=External device alarm current{apps}- O WIRE SCHEDULE No F=Duration panel must remain in alarm after standby period ends(hours). L I ' I T m j G=Spare battery capacity{percentage}. LETTER TYPE USE w c II®i IIIA I®i o ®® ®®®®®® ®®® ®®° , RS-232 12 + z s s s s z a t z A 1 PAIR 16 AWG. TESTED FPLP DATA LOOP/NETWORK B 2 PAIR 20 AWG. (T.1) I - C 1 PAIR 14 AWG. TWISTED FPLP BPSCKT/24VDC E 1 PAIR 16 AWG. TWISTED FPLP AUDIO CKT I- U W o \_J SEE FAO.1 FOR WIRE SCHEDULE NOTES & GUIDELINES.U T MODULE MONITORO cL o OPTIONAL BATTERY REVISIONS o (PROVIDED) REV DESCRIPTION DATE APPROVED Y 12VAC POWER INPUT m EARTH GROUND (BY OTHERS) I 1 OEG REVIEW 03/20/19 R. PUUOFF .- o 0 z CELLULAR COMMUNICATOR BATTERY SIZING CALCULATIONS & DETAIL d RLCD-C REMOTE ANNUNCIATOR DRAWN BY: D. SQUIRES SD- T SCALE:NOT TO SCALE PROJECT ENGINEER: B. DUFFEL o SCALE:NOT TO SCALE - - -- -- PROJECT MANAGER: R. PULIOFF 0 JOB NUMBER: 302-FN-H0441 U 0 J I COSHOP DRAWING NTRAC TYPE UBMI�& DEC:[ 01/25/2019ATE: DESIGN BUILD: III PROJECT NAME: JAGUAR LAND ROVER 10125 SW Washington Sq. Rd. Portland, OR 97223 Q ..0) SHEET NAME: 0 N N SPECIAL FIRE ALARM M FUNCTIONS DETAILS O H o 2 DRAWING: E3 FA3 .4 CC (,) 0 Z 0 RESERVED RESERVED SCALE:NOT TO SCALE SCALE:NOT TO SCALE w N