Plans (47) BU P2019-00072 01 00 00 GENERAL DATA 5. PROVIDE ACOUSTIC GASKETS WHERE WALL INTERSECTS STOREFRONT.QUIETJOINT SHH WHERE WALL 5. VACANT SPACE SHALL HAVE DEDICATED GAS SERVICE FOR FUTURE BUILD-OUT OR FREEZE PROTECTION. PROJECT NARRATIVE �/Y GENERAL REQUIREMENTS MEETS MULLION AND QUIETJOINT SHG WHERE WALL MEETS GLAZING.COLOR SELECTED BY ARCHITECT. 6. UNITS: LENNOX,TRANE,YORK OR CARRIER-7 1/2-TON MAXIMUM UNIT SIZE. ANY UNIT IN EXCESS OF 7 1/2 ���✓ 1 `L 6. AT ALL EXISTING WALLS,REMOVE ALL NAILS,SCREWS,FASTENERS,ETC.LEFT BY PREVIOUS TENANT AND TONS SHALL HAVE SPECIAL WRITTEN APPROVAL FROM PACTRUST. PROJECT CONSISTS OF RENOVATION WORK TO 3,000 SF OF EXISTING OFFICE AND 1. VERIFY ALL DIMENSIONS AND CONDITIONS SHOWN ON DRAWINGS AND AT THE EXISTING BUILDING AND PATCH HOLES READY FOR PAINT. WAREHOUSE SPACE. WORK SHALL INCLUDE BUT NOT BE LIMITED TO DRYWALUMETAL NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO STARTING THE WORK. 7. HVAC UNITS EQUAL TO OR GREATER THAN 5-TONS TO HAVE DUCT SMOKE DETECTORS AND BE CONNECTED �-� #3082 ,� 2. CONTRACTOR AND ALL SUBCONTRACTORS SHALL PERFORM DUE DILIGENCE INSPECTION OF ALL EXISTING 7. REPAIR GYPSUM BOARD AT REMOVED ELECTRICAL RECEPTACLES OR DATA BOXES AND FINISH READY FOR TO A MONITORING STATION WITHIN THE BUILDING. STUDS, SUSPENDED CEILINGS, DOORS/FRAMES AND PAINTING. ALL WORK TO MEET ADA V CONDITIONS PRIOR TO SUBMITTAL OF A PROPOSAL.SUBMITTAL OF A PROPOSAL SHALL BE CONSIDERED PAINT 8. ROOF TOP UNITS SHALL BE PLACED 24'MINIMUM FROM ROOF EDGE TO CENTER OF UNIT. MULTIPLE UNITS REQUIREMENTS. it MARTIN W.HANSON CONFIRMATION THAT SUCH INSPECTION HAS BEEN MADE,AND NO FURTHER COMPENSATION SHALL BE DUE 8. UPON REMOVAL OF WALL BASE,REMOVE RESIDUAL ADHESIVE AND PREP WALL TO PAINT READY CONDITION. SHALL BE PLACED SYMMETRICALLY IN A LINE BASED ON LOAD CALCULATIONS BY STRUCTURAL ENGINEER. _ BELOW ROOFING. •r CIA KAM4S,OREGON THE CONTRACTOR FOR CLAIMS ARISING AS A RESULT OF FAILURE TO PERFORM SUCH INSPECTION. WALL CONSTRUCTION MATERIALS 9. CURBS: 14"HIGH CURBS. ASSEMBLED AND LEVELED TO ROOF,ANCHORED TO STRUCTURAL MEMBERS WORK INCLUDED BUT PERFORMED UNDER SEP. PERMIT 3. BY SUBMITTING A PROPOSAL,CONTRACTOR AND ALL SUBCONTRACTORS CERTIFY THAT THEY HAVE 1. PROVIDE STUDS,TRACKS,BRACING,FASTENING AND OTHER ACCESSORIES NECESSARY FOR COMPLETE �j EXAMINED THE SITE AND INCLUDED IN THEIR PROPOSAL ALL WORK NECESSARY TO COMPLETE THE WORK INSTALLATION. �,;,-- - a. PROFESSIONALLY ROOF IN ALL CURBS AND PENETRATIONS BY PACTRUST APPROVED ROOF •�J .� DESCRIBED OR REASONABLY IMPLIED IN THESE DOCUMENTS. THIS INCLUDES BUT MAY NOT BE LIMITED TO CONTRACTOR. SEE DIVISION 1 GENERAL NOTES THIS PAGE. HEATING,VENTILATION &AIR CONDITIONING WORK -J' ALL MATERIALS AND INSTALLATION,DISPOSAL OF EXCESS MATERIALS(USEABLE FINISH MATERIALS SHALL BE 2. FRAMiNG MEMBERS SHALL HAVE THE STRUCTURAL PROPERTIES INDICATED WHERE PHYSICAL STRUCTURAL 0 ai% LEFT IN THE TENANT SPACE AS NOTED ON PLANS),CLEANING AND ALL PREPARATION OF SUBSTRATE PROPERTIES ARE NOT INDICATED,THEY SHALL BE AS NECESSARY TO WITHSTAND ALL IMPOSED LIVE "AADS. b. UNIT MUST BE LEVEL,SEALED WITH NO AIR LEAKS AND COUNTER FLASHED. ELECTRICAL WORK t71 SURFACES PRIOR TO INSTALLATION,AS WELL AS FINAL CLEAN UP. DESIGN FRAMING IN ACCORDANCE WITH AISI SG-673. III jf 1!* c. CONDENSATE MUST BE TRAPPED AT UNIT. 4. IT IS THE INTENT OF THESE CONTRACT DOCUMENTS TO MATCH AND MAINTAIN EXISTING BUILDING 3. COLD-FORMED FRAMING SHALL BE GALVANIZED METAL CONFORMING TO ASTM A446/A 446 M GRADE A(33000 10.SEISMICALLY ATTACH UNIT TO CURB IN CODE-APPROVED METHOD. STANDARDS FOR ALL EXISTING PRODUCTS AND SYSTEMS. UPON DISCOVERY OF A DISCREPANCY TO THIS PSI)G60. .- 11.ALL GAS PIPING SHALL BE STANDARD BLACK STEEL PIPE W/SUPPORTS PER CODE. PIPING SHALL BE RUN BUILDING INFORMATION TENANT INFORMATION PROJECT #19080 INTENTION,THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY. 4. PROVIDE THE-LISTED GYPSUM BOARD PRODUCTS BY U.S.GYPSUM,GEORGIA PACIFIC,NATIONAL GYPSUM OR OWNER: PACIFIC REALTY ASSOCIATES, L.P. TENANT: •_ 5. FURNISH ALL NEW MATERIALS EXCEPT WHERE SPECIFICALLY NOTED OTHERWISE. INSIDE OFED BUILDING WLEAD FLAWORM NGS AT ROOF PENETRATIONS. LEAD ROOF JACKS TO BE SEALED AND AN APPROVED EQUAL. CLAMPED(STAINLESS STEEL WORM GEAR). 15350 SW SEQUOIA PKWY#300 Ideation Promotions and Apparel, Inc. 6. COORDINATE THE WORK OF ALL TRADES. PROVIDE CARPET"WALK-OFF MATS"TO PROTECT EXISTING 5. STANDARD GYPSUM BOARD SHALL BE TYPE'X',5/8"THICK WITH TAPERED EDGES CONFORMING TO ASTM 12.ALL EXISTING AND NEW GAS PIPING EXPOSED TO THE EXTERIOR TO BE PROTECTED FROM RUST AND - PORTLAND,OR 97224 RECEIVED CARPETS. C-36. CORROSION WITH OIL BASED PAINT(COLOR GREY). OCCUPANCY AREAS&LOADS: 7. ALL ROOF PENETRATIONS FROM ABANDONED EQUIPMENT TO BE REMOVED. PATCH AND REPAIR ROOF AND 6. WATER RESISTANT GYPSUM BOARD SHALL BE 5/8"THICK WITH TAPERED EDGES. CONFORMING TO ASTM 13.LOW VOLTAGE IN SEALTITE CONDUIT FROM BELOW ROOF LINE DIRECT TO UNIT. DO NOT EXCEED BEND (503)624-6300 (PHONE) B 1,613 SF 17 OCC ROOF MEMBRANE TO MATCH THE EXISTING ROOF. C-630. RADIUS OF MANUFACTURER'S GUIDELINE. (503)624-7755(FAX) S-2 1,387 SF 3 OCC U MAR 2 6 2019 8. ALL ROOF WORK TO BE PERFORMED BY PACTRUST APPROVED ROOFING COMPANIES. APPROVED 7. AT TOILET ROOMS USE 5/8"USG FIBERROCK BRAND AQUATOUGH INTERIOR PANEL FROM FLOOR 14.ECONOMIZER TO MEET CODE AND AS FOLLOWS: TOTAL 3,000 SF 20 OCC 1 EXIT REQ COMPANIES INCLUDE: TO 48"A.F.F.ON WALLS BEHIND OR ADJACENT TO PLUMBING FIXTURES. NO SUBSTITUTES. a. ARROW ROOFING, 503-460-2767 (EXCEPTION: EXCEPTION AT LOCATIONS TO RECIEVE PLASTIC LAMINATE OR TILE WAINSCOT.) a. 6 TONS AND ABOVE MUST HAVE ECONOMIZER. BLDG.#: OBP II BLDG. C (2obp173) 4-aCITY OF TIGARD PACIFIC ROOFING,503-640-3163 8. AT TILE WAINSCOT LOCATIONS INSTALL CEMENT BACKER BOARD Y:"THICK WITH SQUARE,REINFORCED, b. BAROMETRIC RELIEF ON 5-7 1/2 TON UNITS. NUMBER OF REQUIRED PLUMBING FIXTURES 'FUILDING DIVISION b. SMOOTH EDGES. PROVIDE DUROCK BRAND CEMENT BOARD OR APPROVED EQUAL. c. 8 TONS AND ABOVE MUST HAVE POWER EXHAUST. CONST.TYPE.: Ill-B NOT SPRINKLERED TOTAL OCC LOAD=20 c. ROOF TOPPERS,360-574-7248 9. INSTALL WATER-RESISTANT GYPSUM BOARD BEHIND WAINSCOT OF FRP,PLASTIC LAMINATE,ETC. 2014 OSSC TABLE 2902.1 fN d. 1 1/2 THRU 4-TON OSA INTAKE WITH DAMPER. d. GOT YOU COVERED ROOFING,503-975-9136 BUILDING AREA: 29,138 TOTAL 1 FIXTURE PER 25 FOR FIRST 50 OCC 10.TRIM ACCESSORIES SHALL COMPLY WITH ASTM C 1047. 15.ALL UNITS TO MEET OR EXCEED CURRENT ENERGY EFFICIENCY CODE REQUIREMENTS. 9. KEEP THE AREA OF WORK FREE OF GARBAGE AND DEBRIS ON A DAILY BASIS INCLUDING DOCK ACCESS 11.USE GEORGIA PACIFIC DENSGLAS GOLD ON EXTERIOR FACE OF EXTERIOR WALLS AND COAT WITH STO FINISH1 FIXTURE REQUIRED-2 PROVIDED AREAS AND COMMON AREA. FLOORS TO BE SWEPT OR VACUUMED DAILY. - SYSTEM. 16.DROP CANS TO BE SAME SIZE AS CURB OPENING AND TO EXTENDED TO WITHIN 2'OF SUSPENDED CEIILING. ALLOWABLE AREA PER 2014 OSSC. • MINIMUM 26 GAUGE FOR SUPPLY AIR. SEAL EDGES OF SUPPLY AIR. 10.PROVIDE ADEQUATE PROTECTION TO ALL EXISTING IMPROVEMENTS INCLUDING BUT NOT LIMITED TO. WALL CONSTRUCTION EXECUTION COMMON CORRIDORS AND STAIRS,BUILDING ENTRANCES,SUITE ENTRANCES,ETC. THE CONTRACTOR WILL - 17.DISTRIBUTION DUCTWORK: - 1. FASTEN FRAMING MEMBERS TOGETHER BY WELDING OR BY USING SELF-DRILLING OR SELF-TAPPING TYPE AREA FRONT.INC. TOTAL ALLOWED O 0 BE RESPONSIBLE FOR THE REPAIR OF ANY DAMAGES TO EXISTING IMPROVEMENTS DUE TO CONSTRUCTION a. SPIRAL DUCT PERMITTED ONLY IF EXPOSED. _ ACTIVITIES. - - SCREWS. WELDING SHALL CONFORM TO AWS D13 WELDING PROCEDURE. ELECTRODES AND SCREW B = 19,000 + 14,250 . = 33,250 SF _ 0 0 11.PROVIDE TEMPORARY SANITARY FACILITIES. CONSTRUCTION WORKERS SHALL NOT USE BUILDING CONNECTIONS SHALL BE AS REQUIRED AND INDICATED IN THE DESIGN CALCULATIONS. DO NOT FIELD WELD b. 26 GAUGE OR TO SMACNA STANDARDS WHERE DUCT IS CONCEALED ABOVE A CEILING. S-2= 26,000 + 19,500 = 45,500 SF RESTROOM FACILITIES. MATERIALS LIGHTER THAN 18 GA. c. WRAP CONCEALED SUPPLY DUCTWORK IN NON-CONDITIONED AND SEMI-CONDITIONED SPACE WITH - C }- 2. PROVIDE ACCURATELY ALIGNED RUNNERS AT TOP AND BOTTOM OF PARTITIONS. ANCHOR TRACKS AS MINIMUM R4.2 INSULATION WITH FSK BARRIER. 12.STORAGE AND STAGING OF CONSTRUCTION MATERIALS SHALL BE LIMITED TO AREAS AS DESIGNATED AT - INDICATED IN THE DESIGN CALCULATIONS. BUTT WELD JOINTS IN TRACKS OR SPLICE WITH STUD INSERTS. d. HANGERS 12 GAUGE WIRE OR 18 GAUGE 1"WIDE STRAP. EXPOSED DUCT MUST HAVE ALL THREAD CODE SUMMARY > PRE-CONSTRUCTION MEETING. UNDER NO CIRCUMSTANCES SHALL BUILDING UTILITY AREAS OR ANY OTHER FASTENERS SHALL BE AT LEAST 3 INCHES FROM THE EDGE OF CONCRETE SLABS. T , N COMMON BUILDING AREA BE USED FOR STORAGE. HANGERS AND FULL DIAMETER STRAP UP TO 18"0. LARGER THAN 18"MUST HAVE SADDLE TYPE CLAMP. i 13.KEEP THE ROOF FREE OF DEBRIS I.E.NAILS,SCREWS,BOTTLES,ETC.)AT ALL TIMES. 3. CUT STUDS SQUARE AND SET WITH FIRM BEARING AGAINST WEBS OF TOP AND BOTTOM TRACKS. POSITION e• BRANCH DUCTS SHALL BE PLUMB AND SQUARE(NO OCTOPUS). TEES SHALL BE MAXIMUM OF 45 ALL CONSTRUCTION WORK SHALL BE DONE IN COMPLIANCE WITH STATE AND Q N ( STUDS VERTICALLY IN TRACKS AND SPACE AS INDICATED IN DESIGN. DO NOT SPLICE STUDS. PROVIDE AT DEGREES. - 14.ALL DIMENSIONS ARE TO FACE OF GYPSUM BOARD UNLESS OTHERWISE NOTED. LEAST TWO FULL HEIGHT KING STUDS AT DOORS AND OTHER OPENINGS 2 FEET WIDE OR LARGER. PROVIDE. -- LOCAL CODE REQUIREMENTS THAT APPLY, INCLUDING BUT NOT LIMITED TO: ' 0 rn 15.CONFIRM SIZES OF ALL OPENINGS REQUIRED FOR THE INSTALLATION OF STRUCTURAL,MECHANICAL, JACK STUDS OVER OPENINGS,AS NECESSARY,TO MAINTAIN INDICATED STUD SPACING. PROVIDE TRIPLE f. EACH BRANCH DUCT TO HAVE BALANCE DAMPER IN Y BRANCH. • 2014 OREGON STRUCTURAL SPECIALTY CODE ELECTRICAL AND PLUMBING WORK PRIOR TO FRAMING OR CUTTING FOR INSTALLATION. STUDS AT CORNERS,POSITIONED TO RECEIVE INTERIOR AND EXTERIOR FINISHES. FASTEN STUDS AT TOP g. ALL DISTRIBUTION DUCT WORK TO BE INSTALLED MIN.24"ABOVE FINISH CEILING. w " p � AND BOTTOM TRACKS BY WELDING OR SCREWING BOTH FLANGES TO THE TRACKS.PROVIDE LONG LEG • 2014 OREGON MECHANICAL SPECIALTY CODE (AMSC) W 16.LEAVE THE PROJECT CLEAN AND READY FOR OCCUPANCY. - TRACK AT TOP OF WALL TO ALLOW FOR DEFLECTION WHERE WALL MEETS STRUCTURE ABOVE. 18.FLEX DUCT WILL BE NO LONGER THAN 6'FROM RIGID DUCT DOWN TO DIFFUSER. • 2014 OREGON ELECTRICAL SPECIALTY CODE (OESC) c u) ti 17.CLEAN ADJACENT EXTERIOR AREA,I.E.WALKS,EXTERIOR GLASS,ETC. 4. INSTALL ALL INTERIOR AND EXTERIOR GYPSUM BOARD PRODUCTS AND ACCESSORIES AS REQUIRED FOR 19.DIFFUSERS: • 2014 OREGON FIRE CODE (OFC) +-+ Q `t 18.FILL ALL PAPER AND SOAP DISPENSERS IN RESTROOMS AND BREAK AREAS. THE PROJECT. a. • SUSPENDED CEILING SYSTEM(T-BAR)-PERFORATED FACE ADJUSTABLE CURVED BLADES-DESIGN - , J g 19.CLEAN ALL SUPPLY AND RETURN DIFFUSERS AT PROJECT COMPLETION. ral 5. AT TOILET ROOMS TO RECEIVE SHEET VINYL FLOORING, INSTALL THE GYPSUM BOARD(OR AUQATOUGH) - TITUS PCS SUPPLY AND TITUS PAR RETURN OR APPROVED EQUAL. • ASCE-7-10 CO10 M WITH 1/4"GAP BETWEEN THE BOARD AND THE FLOOR TO PREVENT WICKING. b. GYPSUM BOARD CEILING;SUPPLY-CURVED BLADE W/OBD DESIGN TITUS 250;RETURN-BAR TYPE- • ICC/ANSI Al 17.1-2009 C 20.PROVIDE"AS-BUILT"DRAWINGS OF THE WORK AT THE CONCLUSION OF CONSTRUCTION."AS-BUILT" 6. COMPLY WITH USG GYPSUM CONSTRUCTION HANDBOOK AND MANUFACTURER'S RECOMMENDATIONS. DESIGN TITUS 350;EXHAUST-METAL OR ALUMINUM-1/2"x 1/2"EGG CRATE DESIGN TITUS 50F. • 2014 OREGON ENERGY EFFICIENCY SPECIALTY CODE G `o DRAWINGS MAY BE IN THE FORM OF TWO COPIES OF CONSTRUCTION DOCUMENTS MARKED-UP WITH RED to to RECORD DRAWINGS TO THE ARCHITECT. COMPLETE OPERATION AND MAINTENANCE MANUALS 7. FINISH QUALITY: C. ALL SUPPLY REGISTERS TO HAVE MANUAL VOLUME DAMPERS LOCATED IN DUCT AT OR NEAR CLOSEST - - IZ PEN.DELIVER WYE BRANCH. - - SHALL BE PROVIDED FOR ALL MECHANICAL,ELECTRICAL AND PLUMBING EQUIPMENT.PROVIDE AS-BUILT CAD AREA - PROCESS TRADE NOMENCLATURE FILES TO PACTRUST FOR ALL MEP TRADES.PACTRUST MAY HOLD CONTRACTOR'S FINAL PAYMENT UNTIL - d. CLEAN OR REPLACE ALL SUPPLY AND RETURN AIR GRILLS AND THEIR HOUSINGS AT PROJECT - 0 "AS-BUILT"DRAWINGS AND 0&M MANUALS HAVE BEEN RECEIVED AND APPROVED. WAREHOUSE TAPE/FINISH COAT* TIGHT DOUBLE(LEVEL 3) - COMPLETION. - 21.IT IS THE INTENT OF THE CONTRACT DOCUMENTS THAT THE CONTRACTOR PROVIDE A COMPLETE, OFFICE/OTHER AREAS - TAPE/2 FINISH COATS`! SMOOTH FINISH TAPED(LEVEL 4) 20.THERMOSTAT: ALL EXISTING MERCURY TYPE THERMOSTATS TO BE REPLACED. NEW THERMOSTATS TO BE - - / D FUNCTIONING PROJECT INCLUDING ALL GENERAL,MECHANICAL AND ELECTRICAL CONSTRUCTION REQUIRED USG"FIRST COAT •SAND AFTER TAPE/FINISH COAT(S) HONEYWELL COMMERCIAL GRADE VISIONPRO 8000 TOUCH SCREEN MODEL TB8220U1003 WHERE POSSIBLE. CO TO FULFILL THAT INTENT. ALL ITEMS REQUIRED SHALL BE FURNISHED AND INSTALLED,REGARDLESS OF NOTE:AT EXTREMELY DARK ACCENT WALLS PROVIDE LEVEL 5 FINISH. APPROVED SUBSTITUTE: TOTAL-LINE SIGNATURE COMMERCIAL THERMOSTAT MODEL NO.P374-2800 -7 DAY WHETHER OR NOT SHOWN ON THE DRAWINGS. PROGRAMMABLE WITH LOCKOUT FUNCTION-AUTO CHANGEOVER ONLY. MOUNT AT ADA HEIGHT(MAY - CO 22.ITEMS OR WORK NOT TO BE FURNISHED OR ACCOMPLISHED BY CONTRACTOR ARE NOTED"N.I.C.". 8. FINISH EXPOSED INTERIOR GYPSUM BOARD WALLS AND CEILINGS SMOOTH STRAIGHT READY FOR FINISH AS REQUIRE CHANGING HEIGHT AT"REPLACEMENT"LOCATIONS). CONTRACTOR SHALL PROGRAM - - SHOWN ON PLANS. THERMOSTATS AND BALANCE SYSTEM. \\ INTERSTATE 5 23."ALIGN"AS USED 1N THESE DOCUMENTS,MEANS TO ALIGN THE FINISHED FACES OF ELEMENTS IN THE SAME 09 53 00 SUSPENDED ACOUSTICAL CEILING 21.THERMOSTAT LOCATIONS TO BE REVIEWED BY ARCHITECT PRIOR TO INSTALLATION. / _C) PLANE,EITHER IMMEDIATELY ADJACENT TO ONE ANOTHER OR ACROSS AN OPENING. CARMAN RD. 0 24.D0 NOT DISASSEMBLE SETS OF CONSTRUCTION DRAWINGS.DRAWINGS ARE INTERRELATED. -- 1. IN EXISTING SPACES,REPLACE EXISTING CEILING TILES WITH ARMSTRONG FINE FISSURED#1732,24x24x5/8" 22.WAREHOUSE HEAT: EXIT#291 ' N W/ANGLED TEGULAR EDGE. a. GAS FIRED UNIT HEATERS USED IN NON-CONDITIONED AREAS SHALL COMPLY WITH CURRENT STATE 25.SUBMIT SAMPLES OR DRAW DOWNS FOR ALL FINISHES REQUESTED TO THE ARCHITECT OF RECORD WITHIN TWO WEEKS OF PROJECT AWARD.PRODUCTS 2• CONDITION SO THAT CALL TILE CUTS SHALL BE DONE WITH RAZOR SHARP KNIVES. CUT/TRIM TILE EDGE TO CREATE TEGULAR EDGE ENERGY CODE REQUIREMENTS. PROVIDE ADJUSTABLE T-STAT FOR EACH UNIT. -- -- REPLACEMENT AT CONTRACTOR COST.AN APPROVEDINSTALLED ITHOUT APPROVED SAMPLES ARE SUBJECT TO SUBMITTAL DOES NOT CHANGE THE-CONTRACTUAL - -- - - -- -- - 23.EXHAUST FANS: - .•• - - - REQUIREMENT TO PROVIDE THE SPECIFIED ITEMS UNLESS SPECIFICALLY NOTED AS A SUBSTITUTION BY THE 3. TUNE UP GRID SYSTEM TO WITHIN PLUS OR MINUS 0.5 INCHES OF LEVEL. a. CEILING MOUNTED EXHAUST FANS SHALL HAVE A MINIMUM PERFORMANCE TO MEET THE CURRENT s� CONTRACTOR AND SPECIFICALLY APPROVED BY THE ARCHITECT AS SUCH.REPLACE SUCH PRODUCTS AS 4. BENT OR DAMAGED T-BARS TO BE REPLACED. CODE REQUIREMENTS INCLUDING INTEGRAL BACKDRAFT DAMPER AND VENTING TO THE EXTERIOR. GAAP - DIRECTED AT CONTRACTOR'S COST. COOK GEMINI SERIES 100 OR EQUAL;80 CFM WITH A SONE RATING OF 1.6 OR LESS,100 CFM WITH A 5. REPAIR HOLES IN GRID FROM REMOVED WALLS. USE OF ARMSTRONG"BP ES-4"EXPANSION SLEEVE e �D 26.SUBM I COMPLETE SHOP DRAWINGS FOR MILLWORK,SPECIAL SYSTEMS,MECHANICAL,ELECTRICAL AND ACCEPTABLE. SONE RATING OF.9 OR LESS,200 CFM WITH A SONE RATING OF 1.6 OR LESS. Doti` �,� BUILDING LOCATION PLUMBING SYSTEMS(INCLUDING FIRE PROTECTION SYSTEMS). SUBMIT A MINIMUM OF TWO COPIES OF ALL - • F' SHOP DRAWINGS FOR REVIEW AND APPROVAL TO THE ARCHITECT OF RECORD.ARCHITECT WILL RETAIN ONE 09 65 19 RESILIENT FLOORING-VINYL COMPOSITION TILE b. SINGLE FIXTURE RESTROOMS,JANITOR'S CLOSETS OR SINGLE SHOWER ROOMS TO HAVE CEILING �f�t - wr a�_ vsT \ COPY AND ONE COPY WILL BE RETURNED TO THE CONTRACTOR. MOUNTED EXHAUST FANS,WIRED PER DIVISION 16 AND SWITCHED WITH THE LIGHTS. 1. FINISH FLOORING TO EXTEND UNDER CASEWORK. - 27.THE DESIGN OF FIRE PROTECTION SYSTEMS IS THE RESPONSIBILITY OF THE FIRE PROTECTION SYSTEMS c. MULTIPLE FIXTURE RESTROOMS,COMBINATION RESTROOM&SHOWER,AND LOCKER ROOMS TO HAVE •Po CONTRACTOR.ALL FIRE PROTECTION SYSTEMS SHALL BE DESIGNED BY A PROFESSIONAL ENGINEER INSTALL TILES IN QUARTER TURN PATTERN. ROOFTOP MOUNTED EXHAUST FAN,FACTORY CURB AND BACKDRAFT DAMPER,WIRED PER DIVISION 16, LICENSED BY THE APPROPRIATE JURISDICTION FOR THE DESIGN OF THIS TYPE OF SYSTEM. COORDINATE 09 91 23 PAINTING CONTROLS AS REQUIRED BY DESIGN.COOK ACE-D SERIES OR EQUAL. - INTERFACE WITH EXISTING BUILDING SYSTEMS AND WITH ARCHITECT. ALL SPRINKLER HEADS SHALL BE INTERIOR: d. SPECIALTY ROOMS REQUIRING EXHAUST SHALL MEET THE ABOVE MINIMUM REQUIREMENTS- CENTERED IN CEILING TILE(OR 2 x 2 MODULE OF A SECOND LOOK II TYPE OF CEILING TILE WHERE - INDIVIDUAL ROOMS WITH AN EXHAUST REQUIREMENT GREATER THAN 250 CFM,SHALL HAVE A APPLICABLE). LOCATION OF THOSE IN GYPSUM BOARD CEILINGS SHALL BE PRE-APPROVED IN WRITING BY 1. WALLS: ROOFTOP MOUNTED FAN. 11111. THE ARCHITECT PRIOR TO INSTALLATION. a. PRIME NEW DRYWALL WITH MILLER PAINT HIGH-BUILD"SUPER SEAL"PRIMER. 24.HVAC TESTING. / 72nd AVE. 28.COORDINATE ALL CONSTRUCTION SEQUENCING WITH PACTRUST AND SCHEDULE ALL SERVICEb. NEW AND EXISTING DRYWALL TO BE FINISHED TO ACHIEVE UNIFORM COVERAGE WITH MILLER PAINT a. CONTROL SYSTEMS SHALL BE TESTED TO ENSURE THAT CONTROL DEVICES,COMPONENTS, 11 \ /� V INTERRUPTIONS OUTSIDE NORMAL BUSINESS HOURS TO MINIMIZE INCONVENIENCE TO CURRENT TENANTS. 120-4-XX WITH A TIGHT ROLLER STIPPLE FINISH. RESTROOM FINISHES TO BE MILLER PAINT 170-5-XX S/G EQUIPMENT AND SYSTEMS ARE CALIBRATED,ADJUSTED AND OPERATE IN ACCORDANCE WITH ; " C GENERAL LATEX ENAMEL. - APPROVED PLANS AND SPECIFICATIONS. 1. REMOVE ALL EXISTING VCT,SHEET VINYL,ETC.IN AREAS WHERE NEW FLOOR COVERING IS SPECIFIED PRIOR 2. DOORS AND FRAMES: b. SEQUENCES OF OPERATION SHALL BE FUNCTIONALLY TESTED TO ENSURE THEY OPERATE IN - 1 LOCATION MAP 3 TO INSTALLATION OF NEW FLOORING. ACCORDANCE WITH APPROVED PLANS AND SPECIFICATIONS. a. NEW HOLLOW METAL-PRIME,SAND,AND FINISH WITH TWO COATS OF SEMI-GLOSS OIL.SPRAY OR - - Z ED 2. ALL ROOF PENETRATIONS FOR ELECTRICAL,LOW VOLTAGE,GAS PIPING,ETC.SHALL BE SLEEVED THROUGH ROLLED APPLICATION. c. A COMPLETE COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND - A-� NOT TO SCALE 1.9.; a) A LEAD ROOF JACK,CLAMPED WITH A STAINLESS STEEL CLAMP AND SEALED WITH VULKEM 921 •b. EXISTING HOLLOW METAL-SAND,FILL IMPERFECTIONS WITH BONDO,SAND AND PRIME PATCHES WITH FILED WITH PACTRUST. POLYURETHANE SEALANT. SILICONE SEALANT NOT PERMITTED. ALKYD PRIMER,AND FINISH WITH SEMI-GLOSS OIL ENAMEL.SPRAY OR ROLLED APPLICATION 25.PROJECT CLOSE OUT DOCUMENTS REQUIRED: - CU ` 07 00 00 THERMAL& MOISTURE PROTECTION c. WOOD-PRIME WITH ALKYD OIL UNDER-COATER,SAND,FILL ALL FASTENING HOLES WITH PAINTER'S a. AutoCAD FILE SHOWING AS-BUILT INFORMATION. 111171 CD.. 1. REPLACE ALL MISSING AND DAMAGED ROOF AND WALL INSULATION ABOVE THE CEILING GRID. PUTTY,CAULK ALL CRACKS IN CASINGS AND BETWEEN JAMBS AND WALLS USING DAP LATEX CAULK, b. ELECTRONIC PDF FILE OF THE AutoCAD FILE ABOVE. • 2. PROVIDE NEW ROOF INSULATION TO MATCH EXISTING AT ABANDONED MECHANICAL UNITS. AND FINISH WITH SATIN OIL ENAMEL. AREA OF WORKij CI d. WOOD-STAIN,SEAL AS REQUIRED,AND VARNISH WITH SATIN VARNISH. - c. HARD COPY OF AutoCAD FILE ABOVE. p 3 ® 0 Q Q Q '? 'z 3. AT ALL UN-USED EXISTING ROOF PENETRATIONS,REMOVE EQUIPMENT AND REPAIR ROOF SYSTEM. ( p 11enYS•zsNOM.s�s d. OPERATIONS MANUALS FOR ALL EQUIPMENT,INCLUDING T-STATS. 3. CEILINGS: -- 08 10 00 DOORS AND WINDOWS r_ -0 a. EXISTING GYP BOARD/PLASTER-SAND,SPACKLE ALL IMPERFECTIONS,SPOT PRIME AND FINISH TO e. COLORED ZONE MAP WITH THERMOSTAT LOCATIONS INDICATED. o- r I I ---� ` - n------ry �'\ 1. RE-USE EXISTING DOORS AND FRAMES WHERE POSSIBLE ACHIEVE UNIFORM COVERAGE WITH MILLER PAINT 6200 OR 4480. 26 00 00 ELECTRICAL: DESIGN/BUILD , c - 2. APPROVED DOOR,FRAME,AND HARDWARE SUPPLIERS INCLUDE: b. NEW GYP BOARD/PLASTER -PRIME WITH SUPER SEAL AND FINISH TO ACHIEVE UNIFORM COVERAGE GENERAL WITH MILLER PAINT 6200 OR 4480. 111 E u_ a. BAXTER AND FLAMING. (503)225-0486 1. ALL ELECTRICAL FEEDS TO OUTLETS,SWITCHES, ETC.MUST BE VERTICAL DROPS FROM ABOVE EXCEPT FOR 4 CU b. D&D DOOR (503)205-5533 4. GENERAL NOTES: HORIZONTAL RUNS UNDER WINDOWS AND RECEPTACLES ON THE SAME STUD. I J� C. BENSON INDUSTRIES (503)907-2200 - a. KEEP ALL HARDWARE,HINGES,AND DOOR KNOBS CLEAN OF ALL PAINT SPLATTERS,DRIPS,OR ROLLER 2. ALL ELECTRICAL FEEDS TO OUTLETS AND DATA BELOW WINDOW SILLS TO BE ROUTED THROUGH BUILDING 4� - SPRAY. SHELL WALLS. DO NOT FEED FROM PERPENDICULAR INTERIOR PARTITIONS. - I I C 0 ci 3. PROVIDE LABELS AT EACH ELECTRICAL RECEPTACLE IDENTIFYING CORRESPONDING PANEL AND BREAKER. o--L d. GRANT SUPPLY (360)887-0647 b. ALL SURFACES TO BE SANDED BETWEEN COATS,PRIOR TO INSTALLATION OF NEXT COAT. _ _ 3. DOOR AND RECITE FRAMES SHALL BE TIMELY,OR APPROVED. SUBMITTAL REQUIRED PRIOR TO ORDERING i MATERIAL.NEW FRAMES TO BE FACTORY FINISH CUSTOM COLOR. c. DURING PROGRESS OF WORK,KEEP JOB SITE CLEAN OF ALL PAINT MATERIALS,RUBBISH,CANS,AND 4. PROVIDE TYPEWRITTEN UPDATED SCHEDULE AT PANEL TO IDENTIFY CIRCUIT BREAKERS. - ;13- ...I '..1. 0 } l I I I " RAGS AT THE END OF EACH DAY. -- LLQ 4. FIELD VERIFY EXISTING DOOR,FRAME AND HARDWARE FINISH PRIOR TO ORDERING. ALL NEW DOORS, 5. VERIFY ELECTRICAL METER AND TAG METER WITH THE TENANTS ADDRESS OR SUITE NUMBER. METER (n FRAMES AND HARDWARE TO MATCH EXISTING BUILDING STANDARDS. d. UPON COMPLETION OF WORK,CLEAN ANY PAINT SPLATTER BY USING PROPER METHODS OF WASHING IDENTIFICATION NUMBER AND TENANT ADDRESS INFORMATION SHALL BE GIVEN TO PACTRUST PRIOR TO $ I W M 5. ALL INTERIOR DOORS SHALL BE SOLID CORE WOOD UNLESS NOTED OTHERWISE. AND SCRAPING,USING CARE NOT TO SCRATCH OR DAMAGE FINISHED SURFACES. TENANT'S MOVE-IN. I I� EQ Z co e. PROTECT WORK OF OTHER TRADES. 6. ELECTRICAL CONTRACTOR TO PROVIDE EMERGENCY LIGHTING IN EXIT PATH SHOWN ON PLAN EQUAL TO - I I I O D- O f•-- 6. DOOR HARDWARE SHALL BE SCHLAGE AL SATURN OR D RHODES SERIES U.N.O. 1-FOOT CANDLE. f. PROVIDE"WET PAINT'SIGNS AS REQUIRED TO PROTECT NEWLY PAINTED FINISHES. __ ________ I 7. ALL DOOR HARDWARE SHALL BE INSTALLED WITH A 5"BACKSET. 7. EXIT LIGHTS:RUUD LIGHTING"PLASTIC LED EXIT SIGN"MODEL EXPBURWH RED LETTERS,WHITE ����� I 12 00 00 FURNISHINGS -__-_______ I-------LI ^L. m IY 8. DOOR FINISH SUBMITTAL:CONTRACTOR TO PROVIDE SHOP DRAWINGS FOR DOOR FRAMES,DOOR HOUSING,WITH BATTERY BACKUP. L.L W EX 0 HARDWARE AND DOORS AS WELL AS A CONTROL SAMPLE OF THE FINISHED DOOR SKIN W/STAIN AND FINISH 1. PROVIDE ROLLER BLINDS AT ALL EXTERIOR WINDOWS. 8. WHERE NEEDED,CONTRACTOR TO FURNISH AND INSTALL NEW DRY TYPE TRANSFORMERS TO PROVIDE Z W ,-,- APPLIED APPLIED(IF NEW DOORS ARE BEING PROVIDED). BEFORE FINISHING OF DOORS IS COMMENCED ARCHITECT a. MARIAK CONTRACT CHAIN OPERATED CLUTCH ROLLER SHADES 208V/120V POWER FROM THE 480V/277V SYSTEM. SIZE TO BE BIDDER DESIGN. o CO a. SHALL APPROVE CONTROL SAMPLE. FINISHED PRODUCT IS SUBJECT TO REJECTION BY ARCHITECT IF THIS a O a U PROCESS IS NOT FULLY ADHERED TO AND FIELD PRODUCT DOES NOT MATCH THE APPROVED CONTROL b. INCLUDE SQUARE ALUMINUM FASCIA.BRONZE - - a. TRANSFORMERS TO BE ENERGY STAR LABELED. m SAMPLE. c. FABRIC-MARIAK ECONOSCREEN-3%COLOR-903 GRAY/BLACK U.N.O. b. CASE TO BE TOTALLY ENCLOSED WITH LOUVERS TO PREVENT FOREIGN OBJECTS INTO THE INTERIOR. �--� Z 9. ALL INTERIOR GLAZING SHALL BE TEMPERED. 2. INSTALL BUILDING STANDARD ADDRESS AND/OR SUITE NUMBER LABELS TO ALL EXTERIOR DOORS. - c. ENCLOSED AND VENTILATED,AIR COOLED TYPE,CLASS H INSULATION,DESIGNED FOR 115 DEGREES C Z0 C Q 10.PATCH AND REPAIR ALL HOLES OR DAMAGE TO EXISTING STORE FRONT WINDOWS AND DOORS.TOUCH UP 23 00 00 HVAC : DESIGN/BUILD TEMPERATURE RISE ABOVE 40 DEGREES C AMBIENT TEMPERATURE AT FULL LOAD CONTINUOUS 2 BUILDING PLAN a) 00 W FINISH FOR AS NEW LOOK. - OPERATION. EQUIP WITH 2-1/2 PERCENT ANFC TAPS AND FOUR 2-1/2 PERCENT BNFC TAPS. MAXIMUM (92 W w 11.TOUCH UP ALL EXISTING INTERIOR DOORS AND FRAMES FOR AS NEW LOOK. GAS METER SOUND LEVEL SHALL BE NEMA STANDARD WITH ISOLATION DAMPERS BETWEEN THE CORE AND COIL 50' ASSEMBLY AND CASE. A-O SCALE 1" = 12.OVERHEAD DOORS;WAYNE DALTON THERMOSPAN 125, EXTERIOR WHITE/STUCCO. FLUSH STEEL INSULATED, 1. CONTRACTOR TO VERIFY GAS METER AND TAG METER WITH THE TENANTS ADDRESS OR SUITE NUMBER. J 2"THICK;STANDARD LIFT OPERATING STYLE WITH TRACK AND HARDWARE. OPERATION;PULL ROPE FOR METER IDENTIFICATION NUMBER AND TENANT ADDRESS INFORMATION SHALL BE GIVEN TO PACTRUST PRIOR 9. LOW VOLTAGE SYSTEMS(TELECOMMUNICATION AND DATA)BY FUTURE TENANT. DOORS TO 10'TALL,CHAIN HOIST FOR TALLER DOORS. TO TENANTS MOVE-IN. 10.LIGHTING ENERGY MANAGEMENT IS REQUIRED IN ALL BUILDINGS. DEFERRED DATE: 3/6/19 13.TUNE UP EXISTING OVERHEAD DOORS FOR SMOOTH OPERATION. WORK INCLUDES: HVAC-BID PROCEDURE - 11.00CUPANCY CONTROL DEVICES SHALL BE LEVITON OR WATT STOP. LEFj EiiREj� PERMIT SET a. ADJUST OVERHEAD SPRING TENSION TO MEET MANUFACTURER'S SPECIFICATIONS. 1. FOR BIDDING PURPOSES,THE HVAC CONTRACTOR WILL ASSUME THAT EXISTING HVAC EQUIPMENT IS IN 12.TEST ALL LIGHTING CONTROL SYSTEMS TO ENSURE THAT CONTROL DEVICES,COMPONENTS,EQUIPMENT y PROPER WORKING ORDER. AND SYSTEMS ARE CALIBRATED,ADJUSTED AND OPERATE IN ACCORDANCE WITH APPROVED PLANS AND Flre Sprinkler ,,, b. REPLACE TOP AND BOTTOM DOOR SEALS AS NEEDED. 2. INVENTORY EXISTING H.V.A.C.ROOFTOP UNITS AND SUBMIT TO ARCHITECT A CONDITIONS REPORT OF EACH SPECIFICATIONS. SEQUENCES OF OPERATION SHALL BE FUNCTIONALLY TESTED TO ENSURE THEY OPERATE Fire Alarm REVISION c. REPLACE BENT TRACKS AND PANEL SECTIONS. UNIT IN ACCORDANCE WITH APPROVED PLANS AND SPECIFICATIONS. .MechSnicet d. REPLACE ROLLERS AND HINGES AS NEEDED. - 3. LIST TONNAGE OF EACH UNIT. 13.REMOVE ALL UNUSED DATA AND POWER BOXES AND INFILL WITH GYP BOARD. EXCEPTION-UNUSED DATA - Plumbing e. REPLACE ROPES AS NEEDED. HVAC-DESIGN PROCEDURE BOXES UNDER WINDOW SILLS TO REMAIN. ALL BLANK COVER PLATES TO BE BUILDING STANDARD FINISH. �'"' 1. 14.REMOVE ALL UNUSED LOW VOLTAGE WIRING(TELEPHONE AND DATA)FROM THE RECEPTACLE TO THE ElectcFcalE • f. LUBRICATE ROLLERS 1. USE EXISTING AND/OR NEW EQUIPMENT TO DESIGN MECHANICAL H.V.A.C.SYSTEM PER DESIGN STANDARDS DISTRIBUTION BOARD.LEAVE PULL STRINGS FROM THE BOX TO THE SPACE ABOVE THE CEILING. A SECTION Truss Engineering „� 2. • 09 00 00 FINISHES - LISTED BELOW. OF THE EXISTING LOW VOLTAGE WIRE MAY BE LEFT IN LIEU OF A PULL STRING - 2. PRIOR TO AWARD OF CONSTRUCTION CONTRACT,H.V.A.C.CONTRACTOR SHALL SUBMIT TO ARCHITECT FOR Shop Drawings �.. GENERAL • REVIkW AND APPROVAL A FULL DESIGN SCHEMATIC FOR THE TENANT SPACE INCLUDING BOTH OFFICE LIGHTING 4 Other 3. CLEAN,SEAL AND WAX ALL RESILIENT FLOORS PER MANUFACTURERS SPECIFICATIONS. NEW/RENOVATED WORK AND SYSTEMS UNTOUCHED BY THE TENANT IMPROVEMENT AS APPLICABLE. 1. GROUP RE-LAMP EXISTING FLUORESCENT LIGHTS THROUGHOUT U.N.O. �� 2. SUBMIT SAMPLES OR DRAW DOWNS FOR THE FOLLOWING: - INCLUDE THE FOLLOWING: 2. OFFICE LIGHT FIXTURES-LITHONIA 2PM3N G B 3 32 18LD MVOLT ADVANCE OR EQUAL.(NO SYLVANIA - - - • - - 4. a. FLOOR COVERINGS,BASE AND TRANSITION STRIPS -_ a. DUCTING AND SIZES BALLASTS) • 5. b. PLASTIC LAMINATES b. SUPPLY AND RETURN LOCATIONS AND CFM AT EACH GRILL OR DIFUSER 3. LIGHT SWITCHES:ACUITY CONTROLS PRE SET ALL PRIVATE OFFICE AND CONFERENCE ROOM SWITCHES TO crry 017TIGARD "VACANCY"AND TO TURN ON AT LAST DIM LEVEL. *two 6. C. ROOF EQUIPMENT,SIZES AND LOCATIONS REVIEWED FOR CODE COMPLIANCE C. ALL NATURAL WOOD(INCLUDING DOORS AND CASEWORK) k. STANDARD WALL SWITCH WITH OCCUPANCY SENSOR-USE WSD - d. PAINT d. UNITS REQUIRING DUCTED SMOKE DETECTIONI. WALL SWITCH WITH OCCUPANCY SENSOR AND DIMMING-USE WSXD Approved: e 3 7. e. TILE,MARBLE,GRANITE,STONE,GROUT AND SCHLUTER TRIMS e. THERMOSTAT LOCATIONS AND ZONE/UNIT ASSOCIATED THEREWITH • m. WALL SWITCH WITH DIMMING AND CEILING MOUNTED OCCUPANCY SENSOR-USE SPOD OTC, (` - 8. f. TOILET PARTITIONS f. ANY SUPPLEMENTAL EXHAUST FANS OR SPECIAL SYSTEMS WAREHOUSE LIGHTING #: g. ZONE DIAGRAM Pcrunit p aoi - 0Q7Z - g. HARDWARE 1. LITHONIA LIGHTING LED BAY LIGHTING IBG15L SEF AFL GND MVOLT 40K 80CRI LAOZU DWH. - - 3. FINISH FLOORING TO EXTEND UNDER ALL NEW CASEWORK. HVAC DESIGN STANDARDS Address: THE FOLLOWING ARE MINIMUM DESIGN STANDARDS: 2. LITHONIA LIGHTING ELM LT EGRESS LIGHTING. 1 S S„1 f y�p.o k ct.'iv pi/ RD . DRAWN BY: 4. PROVIDE A TRANSITION STRIP WHERE EVER TWO DIFFERENT FLOOR MATERIALS MEET _ #: 09 21 00 GYPSUM BOARD 1. 350 SQUARE FOOT PER TON(UNLESS OTHERWISE APPROVED IN WRITING BY PACTRUST). - R. SUit@ � 11 GENERAL 2. ADDRESS LOADS BY SPECIFIC LOCATION AND USE,AS WELL AS CRITERIA PROVIDED TO PACTRUST BY BY: ....4+_ �� 4 -- � Dates -/� TENANT PRIOR TO CONSTRUCTION: • 1. ALL GYPSUM BOARD WALLS: ONE LAYER 5/8"TYPE X GYPSUM WALLBOARD,EITHER AT RIGHT ANGLES OR a. EXTERIOR EXPOSURE AREAS • PARALLEL TO FRAMING ON EACH SIDE OF METAL STUDS SPACED AT 24"O.C. FASTEN WITH 1"TYPE S - - - • DRYWALL SCREWS 8"O.C.TO VERTICAL EDGES AND 12"O.C.TO TOP AND BOTTOM RUNNERS AND b. INTERIOR AREAS,SIZE AND USE INTERMEDIATE STUDS. STAGGER ALL VERTICAL AND HORIZONTAL JOINTS 24"O.C.(OR ONE STUD SPACING), c. CONFERENCE/TRAINING ROOMS - EACH SIDE AND OPPOSITE SIDES.. - - ALL OFFICE GYPSUM BOARD TO RECEIVE ONE TAPE COAT AND TWO FINISH COATS WITH SANDING BETWEEN d. COMPUTER/SERVER AND TELEPHONE ROOMS TO HAVE PROVISION FOR LOW AMBIENT OPERATION _ _FINISH COATS(LEVEL 4 FINISH). PAINT AS INDICATED. AND 24-HOUR USE.VERIFY NEED FOR A SEPARATE SPLIT SYSTEM TO MAINTAIN TEMPERATURE.3. ALl OTHER GYPSUM BOARD TO RECEIVE ONE TAPE COAT AND ONE FINISH COAT WITH SANDING AFTER FINISH3. SYSTEM DESIGN CRITERIA-SIZE ZONES FOR 3-5 TON UNITS BASED ON USE&EXPOSURE CRITERIA. CI OI" GAR A- U - 2. COAT(LEVEL 3 FINISH). PAINT AS INDICATED. PACKAGED OR SPLIT SYSTEM EQUIPMENT GREATER THAN 5 TONS SHALL BE SPLIT INTO MULTIPLE ZONES. d Approvedby Planning VAV OR WATER SOURCE HEAT PUMP SYSTEMS GREATER THAN 3 TONS SHALL BE SPLIT INTO MULTIPLE e b b 4. IN FINISHED SPACES FURR-OUT BUILDING COLUMNS AND EXTERIOR WALLS WITH 5/8"GYPSUM BOARD OVER ZONES. Date: METAL STUDS. 4. ALL ENCLOSED ROOMS OR OFFICES TO HAVE DUCTED SUPPLY&RETURN GRILLES. Initials: � • - - OFFICE COPY • OD 1lki . #3082 � DOOR SCHEDULE l MARTIN W.HANSON I ' _ i - - _� DOOR DATA FRAME DATA 'HARDWARE • FIRE RATING REMARKS MARK CLA KAM4S,OREGON ,, [-: MARK 1 DOOR SIZE 1 THK 1 CORE VENEER FINISH HAND TYPE FINISH DEPTH 'ACTION MANUFACTURER FINISH FUNCTION �j &Tip P ` T1102 13'-0"x 7'-0" 11 3/4" I SC EI PS RED OAK WATCO Right TIMELY BROWN TONE 4 7/8" - 1 LEVER LATCH SCHLAGE • 613 OIL RUBBED BRONZE AL1OS RELOCATED DOOR AND FRAME 102 8' 1103 3'-0"x 7'-0" 1 3/4" 1 SC I1 PS RED OAK WATCO Left TIMELY BROWN TONE 4 7/8" -- LEVER LATCH 1 SCHLAGE 613 OIL RUBBED BRONZE AL1OS RELOCATED DOOR AND FRAME 103 �� O 0�,� ,Q;: �, •,. 1104 3'-0"x 7'-0" 1 3/4" I SC E'PS RED OAK WATCO Left TIMELY BROWN TONE 14 7/8" - LEVER LATCH I SCHLAGE 613 OIL RUBBED BRONZE AL1OS RELOCATED DOOR AND FRAME 104 I 1 x OFFICE i- `I x - '�_ : C • _, . I' �J 11021 FINISH SCHEDULE PROJECT #19080 \ OPEN OFFICE ( - WALLS CEILINGS REMARKS RM# • RM# NAME FLOOR BASE `-QL 11011 1'-°"� __ NORTH EAST SOUTH 'WEST MATERIAL HEIGHT - WAREHOUSE �, I ;102 -- 1110 101 OPEN OFFICE LP/WOC 4"RF PGWB PGWB E-WW E-SAT 9'-0" -- - 101 V 102 OFFICE LP 4"RF E-PGWB PGWB PGWB E-WW-PGWB E-SAT 9'-0" 102 ' ► 103 OFFICE LP 4"RF E-PGWB PGWB PGWB PGWB E-SAT 9'-0" - 103 1 1 0' 103 I -- _It . 0 I 1104 OFFICE LP . 4"RF E-PGWB E-PGWB E-PGWB E-PGWB E-SAT 9'-0" 104 OFFICE 105 OPEN OFFICE LP 4"RF E-WW-PGWB E-WW-PGWB E-PGWB PGWB E-SAT 9'-0" -- 105 -C ..I __ - _ x 1,031 106 BREAK RM LP-VCT 4"RF ---- r E-PGWB E-PGWB E-PGWB E-SAT 9'-0" -- 1106 0 \ 48LRELITED w w w 1107 I HALL LP 4"RF E-PGWB E-PGWB E-PGWB E-SAT 9'-0" - 107 -e OFFICE z 1108 I W.C. E-SV E-4"RC E-PGWB E-PGWB E-PGWB E-PGWB E-WBC 9'-0" -- 108 11041 - - F — - - _ 1109 W.C. E-SV E-4"RC E-PGWB E-PGWB E-PGWB E-PGWB E-WBC 9'-0" -- 109 •• II \ ' J 11 / 1110 WAREHOUSE SC 4"RC PGWB E-PGWB E-PGWB 1E-CONC. • ETR 9'-0" -- 110 C o Boa', P 1 I o 1111 WAREHOUSE SC 4"RC E-PGWB E-PGWB E-PGWB 1E-PGWB ETR 9'-0" -- 111 0 O —_ HALL 1'_�� }- SC LP 1107 \ • I 1. WI U q, FINISH MATERIALS (FOR BUDGET ONLY) (2016) I g ti 111 . 0 , D ,____A___ ALL FINISHES MUST BE SUBMITTED TO PACTRUST PRIOR TO INSTALLATION. 20 GA 3 5/8" METAL STUD BRACING TO ROOF 0 • W.C. ® ® W.C. I I I 2' I N. � STRUCTURE AT 10'-0' OC TO BUILDING STRUCTURE z I C'1 o tc') 11osci[l bo 11osf II a-CEILING I CARPET LOOP PILE: 2'-0" 2'-0" 1 o o I Box LP-1 MOHAWK GROUP PTR-BROADLOOM"FIBER ART"CROSS KNIT BC375/BQ375 i _ ABOVE FOR WALLS LONGER THAN 12-0 WITHOUT_ F,. „1 W _ INTERSECTION WALLS. FASTEN EACH END WITH �- o a ti 0) - 358 RESHAPED FELT, DIRECT GLUE ¢ oo_ • Z _ I� 4-1 I = USE MOHAWK BRAND NUBROADLOK PREMIUM ADHESIVE ONLY WIP ` (1)#8 SHEET METAL SCREW a • N NWAREHOUSE i�'�J - C ADD POWER WALK-OFF CARPET TILE " oI • 1 O oSOUND INSULATION 4'CENTERED v ( I �' M M111 FOR TENANT OPEN OFFICE WOC MOHAWK GROUP TUFF STUFF II-STEP UP II ` ��� OVER WALL `, _ `� a C �`� o 0 1 1 �! / REFRIGERATOR J 117 0051 983 IRON ORE, DIRECT GLUE / PROVIDE HC SIGNAGE FOR ALL O �— a a_i' _ SUSPENDED CEILING ' I [NEWANDEXISNGHc 'S USE MOHAWK M700 ADHESE. (M95.0 IN HIGH MOISTURE AREAS) _ 2" Zi _ a i 1D C, RACO STYLE RECESSED REVEAL HEADER- / KROY#2835207 BLACK(MEN) w BREAK RM 11 ' CJ V (NOTE: FOR PRICING OF ALL MOHAWK PRODUCTS CONTACT: CONCEPT WALLS#1-487RDT ..V-/ KROY#2835209 BLACK(WOMEN) o �, 11061 11 II BETH GISH(503) 704-4168 or STEPHEN DELONG (971)201-0458 .C. MTL. STUDS. / • r -p • DED.20A---- SEMI RECESSED BOX �� I L - ` V m AT6O A.F.F.FOR POWER AND TV u 4 - VINYL COMPOSITION TILE -�.' 5/8"GYP- BRD. BOTH SIDES w I / MEN /-ADDITIONAL ADDITIONALSWITCH`'� Lu CO AT 60"A. 4/ 411 VCT ARMSTRONG RAFFIA 55804 SMOKE, 12"x 24"x 1/8" z _ I z O zo -/ GANG LOCATION Lu BASE CENTER LINE OF STUD ¢ / O z RF FLEXCO 4"FLAT RUBBER BASE, 071 BLACK/BROWN,AT ALL CARPET AREAS. w = " _ - 8 ` ' I - - o _ o RC • FLEXCO 4"COVE RUBBER BASE, 071 BLACK/BROWN,AT ALL HARD SURFACES. Luo V \ - _ �_ w _�- PARTITION AND POWER PLAN PAINT: 3-1/2" BATT INSUL. IN SOUND ATTENUATION WALLS I \ _ fx v, - v -- ��Z -- — PT-1 MILLER 110-4-10 ACRO PURE ULTRA-LOW VOC, SATIN LATEX O - ELECTRICAL >- F--1 z — z A-11/8" = TO MATCH SHERWIN WILLIAMS SW7029 AGREEABLE GRAY OUTLET OR w �'u) SCALE 1 -0 J-BOX -J w'O cn Q BOTTOM TRACK. . OFFICE NOTES PT-2 MILLER 110-4-10 ACRO PURE ULTRA-LOW VOC SATIN LATEX I a O �Iw • INSTALL NEW OFFICE THERMOSTAT. (LOCATION T.B.D.) 0620 STAR-STUDDED, (ACCENT COLOR) „` _ o a H U • BALANCE HVAC PER NEW WALL CONFIGURATION `_° • NEW CARPET THROUGHOUT (AT ALL RESTROOMS USE MILLER 320-5-10 SEMIGLOSS ACRINAMEL) N fFINISH FLOOR-TOP OF SLAB _ I UNDERCUT DOOR AS M �I • NEW VCT AT BREAK COUNTER • - o REQUIRED TO CLEAR I • NEW PAINT THROUGHOUT PT-3 MILLER 130-1-05 PERFORMANCE PLUSS-FLAT-MIX IXX79W(WAREHOUSE WALLS) FLOOR FINISH 7 7 7 7 DOORS, HARDWAREPSOAK WITH PAC-LIGHT WATCO FINISH 3 WALL SECTION WITH SOUND INS. ( MOUNTING HEIGHTS • HARDWARE 613 OIL RUBBED BRONZE A_1 " —— A-1 _ FRAMES BROWN TONE SCALE 1 I-0" SCALE 1/2" = 1' 0" 0 l - \ --- -- (1) C 11 3 _ .. 1 1 1 1 II II �4,><, h I r 1 0 "3 II I 1 I I ;I I �� �� II 1 I I f 4: �' ii i >< U I TYPICAL STUD r � ll__L4sae�+l1__L____ ' L:i-- -. -- ---1- • " 1 '--�---- yy� _ter - - II I , I f `'�� II i >< ii 1 ' 1 >. ><'' ingl u-- =a==J1--L---- I I`�- U 1 I 1 1 - _\ TYPICAL TRACK ii I 1 I i I ICti If--„==1==,,-F_-1----- n ! 1 I "—I INSTALL STUDS WITH "'�..� n h - �,�I 1 • ) SAME DIMENSION(10"-� t ..III (n R--�==1==i--'---- it IAS . r�I MIN.)FOR BRIDGING r , ALIGNMENT '.; 0 IX L- - - - - lei_ , -.IIef_Il i'-i \ • 1 - } ras �/ If-�--� Y �n EJI J .j _ ., / POWDER DRIVEN ¢ W M (� 1�,• �",',..�� x ANCHORS AT 24"O.C. 0 f1 0 �R� Z so d8 � - Nom, ` (1)#10-16 SCREW w O I I \ PER STUD FLANGE • i'' 4 P(0-30. AT WALLS WITH (n a O ACOUSTIC INSULATION, C I W Liki• • (od $ —I I SET STUD TRACK INA - - - O m CONTINUOUS BED OF -F-� Z rn W ---- - Nu I��\I I� SEALANT. IQ 4 WALL BASE DETAIL � � L13 a . A-1 3" n , , SCALE = 1 0 • H DATE: 3/6/19 • �\ G '�' __, PERMIT SET • x 1 '-RELOCATE S WITCH 9 - �/ REVISION ADD T-STAT FOR WAREHOUSE HEATER AT 60"A.F.F. -I b9 - 1. - (�l 2. ROOF DECK !-L ---7------ . _ . - OR BEAM 3. 4. q-P 4P V 5. SUSPENDED CLG ASSEMBLY 6. 2 REFLECTED CEILING PLAN CTh • 7. A-1 SCALE 1/8" = 1'-0" CEILING NOTES •• A45° I 8. • INSTALL ALL NEW CEILING TILES THROUGHOUT L sig: :: . :.- . ,...y ".:. N:: ........ c::.:- ,:� • RE-LAMP ALL EXISTING AND RELOCATED LIGHT FIXTURES ` I 20 GA 3 5/8" METAL STUD BRACING DRAWN BY: •' • RE-AFFIX ALL LOOSE OR MISSING CEILING INSULATION TO ROOF STRUCTURE AT 10'-0" R.MT. ..7 OC W/(2)#8 SHEET METAL • SCREWS AT EACH END. BRACING - ±' TO BE PROVIDED WHERE DISTANCE ,E . BETWEEN PERPENDICULAR INTERSECTING WALLS OR HORIZONTAL BRACING /1/ .: BETWEEN WALLS EXCEEDS 12'-0"OC • A MEI 5 WALL BRACING DETAIL . A-1 SCALE 3" = 1'-O"