Plans (3) M EC2019-00780 �,.__,..•.ri,,,.r.. ,Ji, ,....,, icy/,. .� ,,,.,.., fi ,,, . .�f,� ,tc,.,. .,/� � f/, �„ /, �,. .✓� ./, 1 2 3 4 . 5 6 7 8 9 10 A B 3 EV1AT]O \ S .... V o � OP • w, ADDITIONAL ABBREVIATIONS ARE DEFINED IN LEGENDS THROUGHOUT THE DRAWING SET, F1�h S AB AIR BARRIER HT HEIGHT AB/VR AIR BARRIER/ VAPOR RETARDER HVAC HEATING, VENTILATING, AND AIR CM OP TIGARD U o AC ASPHALTIC CONCRETE AIR CONDITIONING CONDITIONING ACM ALUMINUM COMPOSITE' MATERIAL 0 NSIDE DIAMETER REVIE D FOR CODE COMPLIANCE �/ i F ACC ACCESSIBLE GU NSULATED GLASS UNIT Q p o ACP ACOUSTICAL CEILING PANEL NCL NCLUDE, INCLUDING Approved: ] C, t3 ACST ACOUSTICAL NFO NFORMATfON OTC: [ O co I Al) AREA DRAIN NSUL NSULATE, INSULATIONv AODM ADDENDUM NT NTERIOR ADJ ADJUSTABLE WD NDIRECT WASTE DRAIN0 Permit #: r e r�0 1 9'- 00 7 g4 , Cle) W ` c AESS ARCHITECTURALLY EXPOSED cip Address: J s } To Sc1�.�J)�.-Vv.() - STRUCTURAL STEEL JANITOR 1 AF ACCESS FLOORING JT JOINT Sisitc#: ti W E _ u. AFF ABOVE FINISHED FLOOR0 n e ill ed ICa I Date: )- O W ,. AAIRLHANDLING UNIT KIT KITCHEN By 7 �(y • Z c ALT ALTERNATE • 00 -1.,- ••• 0 C ALUM ALUMINUM L LONG • CDO ANOD ANODIZED LAM LAMINATE, LAMINATED • APPROX APPROXIMATE LAU LAUNDRY • APT APARTMENT LAV LAVATORY ARCH ARCHITECT, ARCHITECTURAL LT . LIGHT AUTO AUTOMATIC LTG LIGHTING AV AUDIO VISUAL AWP ACOUSTICAL WALL PANEL(S) MAS MASONRY MAILXMATERIAL BB BULLETIN BOARD MAX MAXIMUM -- - BD BOARD MDF MEDIUM DENSITY FIBERBOARD - BLDG BUILDING MDO MEDIUM DENISTY OVERLAY F, I n _ BLKG BLOCKING MECH MECHANICAL ,, E SAE , OTES ] OCT 2019 THE ACTIVATION OF A DUCT BOTTOMBO LOCKIOF MED MEDIUM �CJECT 1R EORIVATIO N POJ - CT DI RECTORY DAWI \G I N JEX CITyoFT r SMOKE DETECTOR SHALL BBRG OT BOTTOM MEMS MEMBRANE ( 1 "�� '° ACTIVATE A VISIBLE A='D BEARING MEZZ MEZZANINE _ . E BRZ BRONZE MGT MANAGEMENT AUDIBLE SUPERVIS�:'_�`i BSMT BASEMENT MFR MANUFACTURE, MANUFACTURE 1. DO NOT SCALE THE DRAWINGS. 12180 SW SCROLLS FERRY RD. TENANT: SIGNAL AT A CONSTA:TLY BUR BUILT UP ROOFING MH MANHOLE TIGARD, OR 97223 ONE MEDICAL GROUP �„ CAB CABINET MIN MINIMUM, MINUTE 2. VERIFY FIELD CONDITIONS PRIOR TO COMMENCEMENT OF EACH PORTION OF THE ATTENDED LOCATION CB CATCH BASIN MIR MIRROW 1 EMBARCADERO CENTER, FLOOR 19 CEM CEMENT, CEMENTITIOUS MISC MISCELLANEOUS WORK. LEASE AREA: 4,500 SF SAN FRANCISCO, CA 94111 o OMISC 606.4.1 CG CORNER GUARD MO MASONRY OPENINGDESIGN MANAGER: AUDREY WALTHERTSHEET NO. CH COAT HOOK MS MOP SINK 3. THE CONTRACT DOCUMENTS, WHICH INCLUDE THE AGREEMENT, THE GENERAL EXISTING OCCUPANCY: M PROPOSED OCCUPANCY: B EMAIL: awolthert�onemedical.com ARCHITECTURAL CI CAST IRON MID MOUNTED CONDITIONS, DRAWINGS, AND SPECIFICATIONS, ARE COMPLEMENTARY, AND WHAT IS I • CJ CONTROL JOINT MTL METAL REQUIRED BY ONE SHALL BE AS BINDING AS IF REQUIRED BY ALL. THE PHONE: (415 233-8272 CIP CAST-IN-PLACE MVBL MOVABLE A-000 GENERAL INFORMATION oCTCL CENTERLINE MWP METAL WALL PANELS CONTRACTOR SHALL COORDINATE ALL PORTIONS OF THE WORK AS DESCRIBED IN CONSTRUCTION TYPE: V-B SPRINKLERED: NO - � 1 f THE CONTRACT DOCUMENTS. NOTIFY THE ARCHITECT FOR RESOLUTION OF ALL A-003 DOOR SCHEDULE, NOTES, HARDWARE 8c DOOR TYPES it �� CLO CEILING DISCREPANCIES PRIOR TO CONSTRUCTION. CLQ CLOSET N NORTH FIRE ALARM: NO SEISMIC DESIGN CATEGORY: D CONSTRUCTION PROJECT MANAGER: A-005 LIFE SAFETY PLAN • p . OA CLR CLEAR NIC NOT IN CONTRACT EMAIM:DON GRAHAM CMU CONCRETE MASONRY UNIT NO NUMBER 4. DIMENSIONS ARE TO THE STRUCTURAL GRID OR TO FINISH SURFACES, UNLESS EMAIN: r AD-110 DEMOLITION PLAN ‘IF q a CO CLEAN OUT, CASED OPENINGOTHERWISEdg ahom�onemed�col.com w Q NOM NOMINAL INDICATED. I PHONE; (415) 50$-$740 A-110 FLOOR PLAN 1. • A COL COLUMN NRC NOISE REDUCTION COEFFICIENTA-330 REFLECTED CEILING PIAN • • � :� O COMM COMMUNICATION NTS NOT TO SCALE 5. ITEMS INDICATED AS BIDDER DESIGNED SHALL BE DESIGNED AND ENGINEERED BY I Vim" CONC CONCRETE THE CONTRACTOR AND/OR SUBCONTRACTOR IN COMPLIANCE WITH APPLICABLE LEGAL CONN CONNECTION CONNECT OC ON CENTER A-140 FINISH PLAN CONSTR CONSTRUCTION OH OVERHEAD REQUIREMENTS, INCLUDING COMPREHENSIVE ENGINEERING ANALYSIS BY A QUALIFIED ARCHITECT: • • �� CONT CONTINUOUS, CONTINUE OD OUTSIDE DIAMETER PROFESSIONAL ENGINEER, USING PERFORMANCE AND DESIGN CRITERIA INDICATED. CALLISONRTKL OREGON ARCHITECTS P.C. A-141 FINISH SCHEDULE • • �ll t .¢ CORR CORRIDOR OPNG OPENING 901 S BOND STREET, A-150 POWER AND SIGNAL PLANf43 • CPT CARPET OPP OPPOSITE BALTIMORE, MD 21231 ( • • CSWK CASEWORK ORD OVERFLOW ROOF DRAIN CONTACT: KEVIN BURKE A-160 FF&E PLAN I • • CTR CENTER OTS OPEN TO STRUCTURE ABOVE EMAIL: kevin.burkeI{{crtkl !.com A-161 FF&E SCHEDULES • D CU CUBIC I PHONE: (206) 623-4646 A-701 INTERIOR ELEVATIONS • • DBL DOUBLE PRCST PRECAST n - A-702 INTERIOR ELEVATIONS 1 • • • F G DEMO DEMOLISH, DEMOLITION PD PLANTERNDRAIN I DET DETAIL PERP PERPENDICULAR I ` - O V AT ` MECHANICAL, ELECTRICAL & PLUMBING A-801 PARTITION TYPES I • DF DRINKING FOUNTAIN PLAN PLASTIC LAMINATE ENGINEERS: E 0. DIA DIAMETER PIAS PLASTER CASE ENGINEERING A-802 CEILING DETAILS — wo 0 DIAG DIAGONAL, DIAGRAM PLYWD PLYWOOD 796 MERUS COURT A-803 INTERIOR DETAIL I a2 `0. DIM DIMENSION PNL PANEL AUTHORITY HAVING JURISDICTION: CITY OF TIGARD S • • G� DIV DIVIDE, DIVISION PL PROPERTY LINE ST LOUIS, MO 63026 I • Y inc.com ineer DMPF DRMPPROOF, DAMPPROOFING PR PAIR BUILDING CODE: 2014 OREGON STRUCTURAL SPECIALTY CODE CONTACT: JOHN VIRTUDAZO A-804 INTERIOR DETAILS • • A I- DN DOWN PRKG PARKING EMAIL: 1 o�c'virtudazaseen9 9 in A-805 FLOOR DETAILS • 0 Cr DR DOOR, DRESSING ROOM PROP PROPERTY - (OSSC, BASED ON 2012 IBC) A-806 TOILET ROOM PLAN AND ELEVATIONS YV DS DOWNSPOUT PT PAINT, POINT, PRESSURE PHONE: (623) 349-1600 x225 • in 'w 0 DW DISHWASHER TREATED ENERGY CODE: 2014 OREGON ENERGY EFFICIENCY SPECIALTY CODE ... H._ DWG DRAWING PIN PARTITION A-840 MILLWORK TITLE SHEET Z- DWR DRAWER E cR ``ICE [ �/5n (OEESC, BASED ON 2009 IECC) A-841 RECEPTION DESK MILLWORK I ctiR RADIUSRISER i R I V E S I 1/ B AHJ: O= EAST RCP REFLECTED CEILING PLAN CITY OF TIGARD PERMIT CENTER I • �v MECHANICAL CODE: 2014 OREGON MECHANICAL SPECIALTY CODE A-842 MILLWORK DETAILS J� E EXISTING RD ROOF DRAIN, ROAD (TMST, BASED ON 2012 IMC) 13125 SW HALL BLVD • i S EXTERIOR INSULATION AND RECPT RECEPTACLE TIGARD, OR 97223 A-843 CONSULT MILLWORK • • FINISH SYSTEM REF REFER TO, REFERENCE PHONE: (503) 718-2439 • Q EJ EXPANSION JOINT REF REFRIGERATOR ® PLUMBING CODE; 2017 OREGON PLUMBING SPECIALTY CODE A-844 LAB STATION MILLWORK EL ELEVATION REINS REINFORCED, REINFORCING (OPSC, BASED ON 2015 UPC) A-845 BREAK ROOM MILLWORK • EIEC ELECTRIC, ELECTRICAL READ REQUIRED A-XXX ELEV ELEVATOR REV REVISED, REVISION Mir %V • ENOL ENCLOSE, ENCLOSURE REG ROOFING ELECTRICAL CODE: 2017 OREGON ELECTRICAL SPECIALTY CODE GENERAL CONTRACTOR; A-846 RI RECEPTION WALL DETAILS I • • C LOS EDGE OF SLAB RM ROOM TBD EP ELECTRIC PANEL RO ROUGH OPENING (TEST, BASED ON 2017 NEPA 70) SPECIFICATIONCLS EQ EQUAL RT RIGHT BUILDINGSECTION INDICATOR WALL SECTION INDICATOR A-901 SPECIFICATIONS I- EQUIP EQUIPMENT I FIRE CODE: 2014 OREGON FIRE CODE • ESCAL ESCALATOR S SOUTH,SPANDREL LANDLORD: • U Q EW EACH WAY SCWD SOLID CORE WOOD I (OFC, BASED ON 2012 IFC} ATLAS INVESTMENT PARTNER A-902 SPECIFICATIONS EXP EXPANSION, EXPOSED SCHEDmMUD808 SW ALDER 5T x`200 A-903 SPECIFICATIONS • Ce 1 C7 SD AIN XX XX ACCESSIBILITY; 2014 OREGON STRUCTURAL SPECIALTY CODE, PORTLAND, OR 97205 A-904 SPECIFICATIONS Z o EXIST EXISTING ECT AFTYO GLASS A-XXX A--XXX CH. 11 - ACCESSIBILITY CONTACT: JIM PARSONS I •• ""'• v FA FIRE ALARM PHONE: (971) 888-4420, (503) 709-9918 r� SGL SINGLE A-905 SPECIFICATIONS • J a CO FCIO FURNISHED BY CONTRACTOR/ SHT SHEET EMAIL: jpar59@comcast.net A-906 SPECIFICATIONS a Q a. W Nin INSTALLED BY OWNER SHTHG SHEATHING ENLARGED DETAIL INDICATOR SECTION DETAIL INDICATOR A-907 SPECIFICATIONS FD FLOOR DRAIN SIM SIMILAR -- T FDC FIRE DEPARTMENT SPEC SPECIFICATION I -- CONNECTION SPKLR SPRINKLER A-908 SPECIFICATIONS FDTN FOUNDATION SPKR SPEAKER ; SCO : E E O E V Y C) /K I I • >- J I FE FIRE EXTINGUISHER SQ SQUARE ® XX XX A-909 SPECIFICATIONS ! 0 J FEC FIRE EXTINGUISHER SS SERVICE SINK IT-901 IT SPECIFICATIONS • WI • < p CABINET SST STAINLESS STEEL � X-xXX 4�0 __ -----_._ __- _ ,- ,_-- _--_ FH FIRE HYDRANT SIC SOUND TRANSMISSION CLASS TENANT IMPROVEMENT 1N THE FIRST FLOOR OF WITHIN AN EXISTING EXTERIOR SHOPPING IT-902 IT SPECIFICATIONS I •• _ 0 FHC FIRE HOSE CABINET STD STANDARD CENTER CONSISTING OF, NON-STRUCTURAL PARTITIONS, CEILINGS, CASEWORK, FIG FIGURE STL STEEL FINISHES, MECHANICAL Z 0 FIN FINISH, FINISHED STOR STORAGE EXTERIOR ELEVATION INDICATOR INTERIOR ELEVATION INDICATOR W CI) FLEX FLEXIBLE STRUCT STRUCTURAL SIGNAGE ELECTRICAL AND PLUMBING WORK. I�-001 MECHANICAL SPECIFICATIONS I • W < v FLR FLOOR, FLOORING SUSP SUSPENDED W I W FLUOR FLUORESCENT G SHOWN IS FOR INFORMATION ONLY. SIGNAGE WILL BE UNDER SEPERATE PERMIT. M-101 MECHANICAL PLAN I • Z C ° I -•� M-301 MECHANICAL DETAILS I • 0 0 �" B ED FACE OF FINISHED OPENING T TREAD, TEMPERED PLUMBING a FOIL FURNISHED BY OWNER T&G TONGUE AND GROOVE I MATCH LINEcr INSTALLED BY CONTRACTOR TC TRAFFIC COATING SEE XX X.X r FO10 FURNISHED BY OWNER/ TEL TELEPHONE XX/A-X0 co P-001 PLUMBING SPECIFICATIONS • Cr. r I INSTALLED BY OWNER TEMP TEMPERATURE, TEMPORARY P-100 PLUMBING PLAN - SANITARY & VENT • FP FIRE PROTECTION FIREPROOF TER TERRAllO x-- FR FRAME, FIRE RATED THK THICK, THICKNESS MATCHLINE INDICATOR KEYNOTE FRMG FRAMING TO TOP OF TRUE NO TRUE NORTH RTH P-200 PLUMBING PLAN - SUPPLY • C7 FRP FIBERGLASS REINFORCED PLASTIC TSTAT THERMOSTATIli- ( I n _ 1 f I V I C I N I TY VIA] I S T _ �l A] P-300 PLUMBING RISERS & SCHEDULES IS I— FRT FIRE RETARDANT TREATED TV TELEVISION P-400 PLUMBING DETAILS FT FOOT, FEET TYP TYPICAL FIG FOOTING FLIT FUTURE UGND UNDERGROUND49 X X ISSUED ! REVISED DATE ____ 1 EVC ELECTRICAL i E HOSE VALVE CABINET UNE UNFINISHED OD SET O�11�6119 FWC FABRIC WALL COVERING UON UNLESS OTHERWISE NOTED I r� E-001 ELECTRICAL SPECIFICATIONS • PROJ[C # LOCATION E--002 ELECTRICAL SCHEDULES PERMIT SET 1Ql7T�19 FWP FABRIC WRAPPED PANEL(S) PROJECT LOCATION _ ,� VERT VERTICAL GA GAGE VEST VESTIBULE EXISTING COLUMN GRIDLINE INDICATOR NEW COLUMN GRIDLINE INDICATOR �`' 7E-101 LIGHTING PLAN GALV GALVANIZED VIE VERIFY IN FIELD 1• GENERATOR VNR VENEER GEN FERRY R ----:: 1 GFRC GLASS-FIBER VR VAPOR RETARDER 5W SCHOL�S E-201 ELECTRICAL POWER PLAN • REINFORCED CONCRETE VWC VINYL WALLCOVERING j -_ -- .. GFRG GLASS-FIBER REINFORCED GYPSUM W WEST, WIDE, WIDTH (FI ) E� <xl �_.- GFRP GLASS-FIBERf � _ . ._.. REINFORCED PLASTIC W/O WITHOUT ••Y •1 \ I - �_ GYP GYPSUM GL GLASS WC WATER CLOSET, WALLCOVERING 5C ' L / 1 1 —J WD WOOD "' A GYP BD GYPSUM BOARD WH WALL HYDRANT DATUM INDICATOR OR WORK POINT FINISH, EQUIPMENT, FIXTURE INDICATOR 1 t 1 VALIDITY OF PERMIT WP WEATHERPROOF, WATERPROOF, ___ -_-- J THE ISSUANCE OF A PERMIT H HIGH WATERPROOFING, WORK POINT HB HOSE BIBB WR WATER RESISTANT \ BASED ON CONSTRUCTION HCWD HOLLOW CORE WOOD WT WEIGHT �' I DOCUMENTS AND OTHER HD HAND DRYERARDWWF WELDED WIRE FABRIC ' DATA SHALL NOT PREVENT HDBD HARDBOARD I E CODE OFFICIAL FROM HDW HARDWARE XMFR TRANSFORMER GENERAL $ �'�\i HDWD HARDWOOD \ .� { pUIRING THE CORR7=CTION HM HOLLOW METAL ID YARD y -'' �� OF�RORS.OSSC105.4 INFORMATION HO HOLD OPEN 1 y" \; HORIZ HORIZONTAL _ .. , HSS HOLLOW STRUCTURAL STEEL HR HOUR I _ A-000 COPYRIGHT © 2019 CALLISONRTKL OREGON ARCHITECTS P.C. I 1 2 3 4 5 6 7 8 9 10 d L 1. CO 0LLo GENERAL REQUIREMENTS DEMOLITION DUCTWORK V 0 -o � •- OC c rn 1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH ALL GOVERNING CODES, LAWS, AND 1. REMOVE ALL EXISTING DUCTWORK, AIR CONDITIONING UNITS, FURNACES, HEATERS, AND ALL 1. DUCTWORK SHALL BE GALVANIZED STEEL CONSTRUCTED & INSULATED IN ACCORDANCE WITH THE73 - REGULATIONS. NOTHING IN THESE SPECIFICATIONS IS TO BE CONSTRUED AS INTENDING TO ASSOCIATED APPURTENANCES AS REQUIRED FOR INSTALLATION OF NEW WORK. REMOVE ALL SHEET METAL AND AIR CONDITIONING CONTRACTORS NATIONAL ASSOCIATION HVAC DUCT 4.2 - Q SUPERSEDE SUCH REQUIREMENTS. EXISTING WORK MADE OBSOLETE BY THE NEW WORK. CONSTRUCTION STANDARDS, LATEST EDITION. n ) .J 0 2. OBTAIN ALL REQUIRED PERMITS, LICENSES, AND APPROVALS AND PAY ALL FEES AND EXPENSES. 2. REMOVE EXISTING ROOFTOP UNITS, EXHAUST FANS, ABANDONED CONDENSING UNIT, PIPING, AND 2. SIZES OF NEW DUCT SHOWN ON DRAWINGS ARE FREE AIRWAYS SIZES, NOT OUTSIDE V/ a ._ p ALL ASSOCIATED APPURTENANCES AS REQUIRED FOR INSTALLATION OF NEW WORK. REMOVE ALL DIMENSIONS. C.)E -1- 0 F 3. ALL WORK SHALL BE DONE IN A GOOD WORKMANLIKE MANNER. EXISTING WORK MADE OBSOLETE BY THE NEW WORK. - Cn 0 3. FOR FINAL CONNECTIONS TO DIFFUSERS, FLEXIBLE DUCTS EQUAL TO WIREMOLD TYPE WG MAY p '- 4. KEEP SITE OF WORK CLEAN AND REMOVE ALL DEBRIS DAILY. ALL NEW & EXISTING WORK SHALL 3. REMOVE EXISTING GAS PIPING, BACK TO METER. COORDINATE REMOVAL AND REPLACEMENT OF BE USED FOR A MAXIMUM OF FIVE FEET. FLEXIBLE DUCTS SHALL BE U.L LISTED, WITH 1" W c BE CLEAN WHEN TURNED OVER TO USER. EXISTING METERS WITH THE LOCAL UTILITY. THICK FIBER VAPOR EXTENDED CHANGES DIRECTION, NO GREATER THAN Y. EGENEROUS RADUS 5. VISIT JOB SITE TO DETERMINE CONDITIONS. NO EXTRA WILL BE ALLOWED FOR WORK 4. COORDINATE DEMOLITION WORK WITH THE WORK OF ALL TRADES AND WITH THE OWNER'S TURNS AND SUPPORT AS REQUIRED TO PREVENT EXCESSIVE SAGGING. tY W CO LL FORESEEABLE BY JOB SITE VISIT. REQUIREMENTS. MINIMIZE THE DURATION OF SHUTDOWNS OF SYSTEMS. 4. PROVIDE ADJUSTABLE SPLITTER, OPPOSED BLADE, OR BUTTERFLY DAMPERS FOR ALL NEW z Z c 6. FIELD VERIFY EXACT LOCATION AND SIZE OF ALL DUCTWORK, PIPING, EQUIPMENT, ETC., BEFORE 5. WHEREVER REMOVING ITEMS, CAP REMAINING PIPING, DUCTWORK, ETC., SO AS TO RENDER SUPPLY, RETURN, & EXHAUST BRANCHES. BALANCING SHALL BE ACHIEVED AT DAMPER NOT • al BEGINNING WORK. REMAINING WORK HARMLESS WITHOUT NUISANCE. DIFFUSER. ••• O 0 - (r) • 7. ALL WORK SHALL BE COORDINATED WITH EXISTING WORK TO REMAIN AND NEW WORK OF ALL 6. WHERE REMOVING PIPING, DUCTWORK, OR CONTROL TUBING REMOVE BACK TO POINT OF NEW 5. PROVIDE DOUBLE THICKNESS TURNING VANES AT ALL ABRUPT ELBOWS. RADIUSED ELBOWS TRADES. CONNECTION OR ALL THE WAY TO MAIN, AS APPROPRIATE. SHALL HAVE CENTERLINE RADIUS AT LEAST AS GREAT AS THE DUCT WIDTH. SEAL 8. THE DRAWINGS ARE DIAGRAMMATIC IN NATURE. THE CONTRACTOR SHALL BE RESPONSIBLE FOR 7. SYSTEMS THAT REMAIN SHALL BE PROPERLY SUPPORTED; NEW SUPPORTS SHALL BE ADDED IF 6. SEAL ALL TRANSVERSE JOINTS AND LONGITUDINAL SEAMS OF ALL NEW DUCTWORK PER SMACNA EXACT LOCATIONS & FINAL COORDINATION AND SHALL PROVIDE NECESSARY OFFSETS AND NECESSARY. WHERE DISCONNECTING AND REMOVING PORTIONS OF SYSTEMS, REMAINING PIPING CLASS B REQUIREMENTS. ELBOWS FOR PLACEMENT OF WORK AT NO ADDITIONAL CHARGE. AND DUCTWORK SHALL HAVE SUPPORTS WITHIN 2 FEET OF END OF REMAINING RUN AND AS _ REQUIRED FOR STABLE SUPPORT. 7. PROTECT NEW DUCT OPENINGS FROM DUST & DIRT. CLEAN INSIDE & OUTSIDE OF NEW 0.0 PRIOF 9. INSYS TEMS EMS INE BID REMODEELBOR,EXISTING MATERIAL SYSTEMS MISCELLANEOUS TOECREATEUCOMPLETE & PROPERLY CONSTRUCTION FUNCTIONING 8. REMOVED ITEMS THAT ARE NOT INDICATED TO BE REUSED SHALL BE TURNED OVER TO THE ODUTLETS AND OPENINGS WITHIN CTWORK IN AREA OF NEW ONEWRK. PCONSTRUCTION ROVIDE TEMPORARY UNERPER DARCHITECTURA DRAWINGS. & 6 IA FOR ALL REIURN 4- GIN 'E SYSTEMS. INCLUDE ALL ITEMS REASONABLY INFERABLE AS NECESSARY FOR THE PROPER OWNER OR REMOVED FROM THE PROPERTY AND DISPOSED OF IN AN APPROVED MANNER, AS CC 1 �' 52821PE no OPERATION OF THE SYSTEM, WHETHER EXPLICITLY SHOWN ON THE DRAWING OR NOT. DIRECTED. `` 411 10. PROTECT EXISTING BUILDING STRUCTURES, GROUNDS, AND WORK TO REMAIN OF ALL TRADES 9. PROTECT SPACES, EQUIPMENT, AND SYS I LMS FROM CONSTRUCTION DIRT AND DUST. ERECT DUST INSULATION & LINING et xi= ", , =X E FROM DAMAGE WHICH MIGHT OCCUR DURING NEW WORK. ANY DAMAGE TO EXISTING FACILITIES BARRIERS AS REQUIRED TO PREVENT CONTAMINATION OF EXISTING SPACES AND NEW OR 6, c • 1 j A , SHALL BE REPAIRED OR REPLACED AND RESTORED TO THE ORIGINAL CONDITION TO THE EXISTING EQUIPMENT. 1. INSULATION SHALL BE AS MANUFACTURED BY OWENS-CORNING, CERTAINTEED, KNAUF, A 1 ,. SATISFACTION OF THE LANDLORD & TENANT. ARMSTRONG, OR GUSTIN-BACON. 10. RECLAIM ALL REFRIGERANT FROM DX EQUIPMENT PRIOR TO DEMOLITION. VENTING OF 11. AREAS OF THE BUILDING MAY BE OCCUPIED DURING CONSTRUCTION. COORDINATE CLOSELY WITH REFRIGERANT TO ATMOSPHERE IS STRICTLY PROHIBITED. 2. ALL SUPPLY AND RETURN AIR DUCTWORK SHALL BE INTERNALLY LINED FOR THE FIRST 25 FEET tPIRATIGIa OATE:1z( t �a�q WORK OF ALL TRADES AND WITH LANDLORD & TENANT TO MINIMIZE DISRUPTION OF BUSINESS DOWNSTREAM AND UPSTREAM OF FAN SYSTEMS. DUCT LINING SHALL BE GLUED AND PINNED TO FUNCTIONS. OVERTIME OR SHIFT WORK REQUIRED TO PREVENT INTERRUPTION OF BUSINESS DUCT AND TREATED TO PREVENT EROSION. AS A MINIMUM, PROVIDE 1" THICK 1 1/2# DENSITY 10/11/2019 OPERATIONS SHALL BE INCLUDED IN BASE BID. THIS SHALL INCLUDE WORK REQUIRING GAS PIPING DUCT LINING. • SHUTDOWN OF SERVICES, WORK PRODUCING NOXIOUS FUMES OR OBJECTIONABLE ODORS, WORK V THAT CREATES EXCESSIVE NOISE IN OCCUPIED AREAS AND WORK THAT IS INHERENTLY 1. LOW PRESSURE GAS PIPING (0.5 PSIG OR LESS) SHALL BE STEEL PIPE: ASTM A 53; TYPE E, 3. AIR CONDITIONING SUPPLY DUCTWORK, OUTSIDE AIR DUCTWORK, AND RETURN AIR DUCTWORK HAZARDOUS TO OCCUPANTS. REVIEWS SCHEDULES BEFORE BIDDING. ELECTRIC-RESISTANCE WELDED OR TYPE S, SEAMLESS; GRADE B' SCHEDULE 40; BLACK, WITH ABOVE THE CEILING AND IN UNCONDITIONED SPACES, WHERE NOT LINED. SHALL APO BE INSULATED = g m THE FOLLOWING FITTINGS: WITH MIN. 1 THICK 1# DENSITY FIBERGLASS WRAP WITH FIRE RETARDANT VAPOR-BARRIER -- 11 a a o 12. IF OVERTIME OR SHIFT WORK IS REQUIRED TO MEET THE SCHEDULE OR ANY SUBSTANTIAL PART A. 3/4- INCH NPS TO 2-INCH NPS: STEEL PIPE, MALLEABLE-IRON THREADED FITTINGS, AND COVERING TO PROVIDE A MAXIMUM INSTALL CONDUCTANCE OF 0.3. OVERLAP ALL SEAMS AND m.n v OF IT, SUCH WORK SHALL BE INCLUDED IN THE BASE BID AND DONE WITHOUT EXTRA COST TO THREADED JOINTS. JOINTS & SECURE WITH MANUFACTURER APPROVED ADHESIVE TO PROVIDE CONTINUITY OF VAPOR z 2 THE OWNER. B. 2-1/2- TO 4-INCH NPS: STEEL PIPE, BUTT-WELDING FITTINGS, AND WELDED JOINTS. BARRIER. LINED DUCTWORK NEED NOT BE INSULATED. 3 = C H w z 4. INSULATE REFRIGERANT SUCTION LINE, COOLING COIL, CONDENSATE DRAIN AND CONDENSATE 13. INSULATION, DUCTWORK, ETC. SHALL HAVE A SMOKE DEVELOPED RATING NO MORE THEN 50 2. INSTALL HANGERS FOR HORIZONTAL STEEL PIPING WITH THE FOLLOWING MAXIMUM SPACING AND PUMP DISCHARGE PIPING WITH 3" FLEXIBLE ELASTOMERICCIL, CINSULATION WITH VAPOR BARRIER •L AND A FLAME SPREAD RATING NO MORE THAN 25. MINIMUM ROD SIZES: JACKET. a 14. SUBMIT SHOP DRAWINGS FOR ALL NEW EQUIPMENT TO ENGINEER FOR REVIEW PRIOR TO A. 1/2-INCH NPS: MAXIMUM SPAN, 72 INCHES; MINIMUM ROD SIZE, 3/8 INCH. B. 3/4- AND 1- INCH NPS: MAXIMUM SPAN, 96 INCHES; MINIMUM ROD SIZE 3/8 INCH :11 W ° ORDERING. C. 1-1/4-INCH TO 2-INCH NPS: MAXIMUM SPAN 108 INCHES; MINIMUM ROD SIZE, 3/8 5. INSULATION AND VAPOR BARRIERS SHALL BE CONTINOUS, INCLUDING THROUGH HANGERS, m H SUPPORTS, PENETRATIONS, ETC. APPLY SUITABLE VAPOR BARRIER COATINGS ON SEAMS & Ci o INCH. JOINTS, OVER STAPLES, AND AT EXPOSED ENDS. AT PNETRATIONS IN JACKETS FOR • 15. SUBMIT COORDINATED SHOP DRAWINGS FOR REVIEW BY THE ENGINEER. THE SHOP DRAWINGS D. 2-1/2- TO 3-1/2- INCH NPS: MAXIMUM SPAN, 10 FEET; MINIMUM ROD SIZE, 1/2 INCH. g ,4 SHALLINDICATE EQUIPMENT, PIPING DUCT, DIFFUSERS, AND THERMOSTAT LOCATIONS. SUBMIT THERMOMETERS AND PRESSURE GAUGES, FILL AND SEAL VOIDS WITH VAPOR BARRIER COATING. -41 a d AND AWAIT REVIEW COMMENTS PRIOR TO FABRICATION AND INSTALLATION. USE BUILDING 3. GAS VALVE STOPS 2-INCH NPS AND SMALLER SHALL BE AGA-CERTIFIED BALL TYPE WITH . so " D STANDARDS WITH CHIEF BUILDING ENGINEER. 6. WHERE PENETRATING FIRE RATED CONSTRUCTION, PROVIDE SUITABLE FIRE STOPPING INSULATION. A ,h CHROME-PLATED BRASS BALL, FOR 2 PSIG OR LESS NATURAL GAS. INCLUDE AGA STAMP, FLAT W ` 16. SUBMIT A PROPOSAL FOR ANY INTENDED DEVIATION FROM THE DESIGN DRAWINGS AND OBTAIN OR SQUARE HEAD OR LEVEL HANDLE, AND THREADED ENDS CONFORMING TO ASME 81.20 APPROVAL BEFORE BEGINNING SUCH WORK. 4. SOLENOID VALVES: BRONZE, ALUMINUM, OR CAST-IRON BODY; 120 VAC, 60 HZ, CLASS B BALANCING 17. INSPECT AND TEST ALL WORK BEFORE PLACING INTO OPERATION. HAVE A QUALIFIED MECHANIC CONTINUOUS -DUTY MOLDED COIL; UL LABELED AND FM APPROVED. INCLUDE NEMA ISC 6, TYPE 4, COIL ENCLOSURE AND ELECTRICALLY OPENED AND CLOSED DUAL COILS. VALVE 1. A QUALIFIED AND CERTIFIED MEMBER OF MBC OR NEBB SHALL COMPLETELY BALANCE AIR AND START UP EQUIPMENT & SYSTEMS IN THE PRESENCE OF THE LANDLORD & TENANT AND POSITION IS NORMALLY CLOSED. INCLUDE THREADED ENDS CONFORMING TO ASME 81.20.1 FOR WATER SYSTEMS AS REQUIRED. CONTRACTOR SHALL SUBMIT A BALANCE REPORT TO THE C� E INSTRUCT THEM IN THE PROPER OPERATION AND MAINTENANCE OF THE EQUIPMENT & SYSTEMS. 2-INCH NPS AND SMALLER AND FLANGED ENDS FOR 2-1/2- INCH NPS AND LARGER. ARCHITECT FOR REVIEW BY THE ENGINEER. le Z 18. PROVIDE OPERATION & MAINTENANCE MANUALS FOR ALL NEW EQUIPMENT AND CONTROLS. 5. EXTEND NATURAL GAS PIPING AND CONNECT TO GAS DISTRIBUTION SYSTEM (GAS SERVICE) 2. AFTER COMPLETION OF ALL REQUIRED WORK, THE CONTRACTOR SHALL OPERATE AND MAKE ANY PROVIDE COPY OF O&M MANUALS TO CHIEF BUILDING ENGINEER PIPING IN LOCATION AND SIZE INDICATED FOR GAS SERVICE ENTRANCE TO BUILDING. GAS REQUIRED ADJUSTMENTS TO EQUIPMENT, DUCTWORK, ETC., AS MAY BE NECESSARY TO PUT THE J Y DISTRIBUTION SYSTEM PIPING, SERVICE PRESSURE REGULATOR, AND GAS METER WILL BE SYSTEMS IN PROPER OPERATING CONDITION. AFTER ALL ADJUSTMENTS HAVE BEEN COMPLETED, I- 19. KEEP A RECORD OF ACTUAL CONSTRUCTION. SUBMIT REPRODUCIBLE "AS-BUILT" RECORD PROVIDED BY GAS UTILITY. THE CONTRACTOR SHALL BALANCE EACH DEVICE TO WITHIN 10% OF VALUE SHOWN ON 0 DRAWINGS AT THE CONCLUSION OF WORK. PROVIDE COPY OF RECORD DRAWINGS TO CHIEF DRAWINGS. ♦Y C BUILDING ENGINEER. 6. INSTALL SHUTOFF VALVE, DOWNSTREAM FROM GAS METER, OUTSIDE BUILDING AT GAS SERVICE N Z w 20. GUARANTEE ALL WORK FOR ONE YEAR FROM THE DATE OF ACCEPTANCE OF SUBSTANTIAL ENTRANCE. 3. CONTRACTOR SHALLSUBMIT FOUR (4) COPIES OF CERTIFIED BALANCE REPORTS TO THE 0 ARCHITECT FOR REVIEW BY THE ENGINEER. SUBMIT AS-BUILT DRAWINGS INDICATING A NJ CO To COMPLETION. 7. INSTALL DRIPS AT POINTS WHERE CONDENSATE MAY COLLECT. INCLUDE OUTLETS OF GAS NUMBERING SYSTEM WHICH CORRELATES ITEMS ON THE PLAN WITH THE BALANCE REPORT. 21. PERFORM ALL CONTROL WORK. COORDINATE WITH ELECTRICAL CONTRACTOR, BASE BUILDING METERS. LOCATE WHERE READILY ACCESSIBLE TO PERMIT CLEANING AND EMPTYING. DO NOT PROVIDE THE LANDLORD WITH A COPY OF THE BALANCE REPORTS. J • CONTROLS VENDOR, AND CHIEF BUILDING ENGINEER. INSTALL WHERE CONDENSATE WOULD BE SUBJECT TO FREEZING. 4. ADJUST MANUAL VOLUME DAMPERS, SPLITTER DAMPERS, & AIR EXTRACTORS AT BRANCH V 4 22. WHERE WORK REQUIRED IS OUTSIDE THE NORMAL AREA OF EXPERTISE OF THE CONTRACTOR 9. INSTALLGAS PIPING AT UNIFORM GRADE OF 0.1 PERCENT SLOPE UPWARD TOWARD RISERS. TAKEOFFS TO ACCOMPLISH BALANCING. BALANCINGt0 SHALL BE ACHIEVED AT DAMPER, NOT INVOLVED HE SHALL HIRE QUAUFIED SUBCONTRACTORS TO PERFORM THAT WORK UNDER HISDIFFUSER. DIRECT SUPERVISION AND RESPONSIBILITY. 10. USE ECCENTRIC REDUCER FITTINGS TO MAKE REDUCTIONS IN PIPE SIZES. INSTALL FITTINGS WITH C LEVEL SIDE DOWN. cc 23. EACH CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CUTTING AND PATCHING REQUIRED BY HIS 11. INSTALL UNIONS IN PIPES 2-INCH NPS AND SMALLER, ADJACENT TO EACH VALVE, AT FINAL CONTROLS I- WORK. CONNECTION TO EACH PIECE OF EQUIPMENT, AND ELSEWHERE AS INDICATED. UNIONS ARE NOT 0 0 REQUIRED ON FLANGED DEVICES. 1. PROVIDE AND INSTALL A COMPLETE SYSTEM OF AUTOMATIC CONTROLS AND INSTRUMENTATION 24. PRIOR TO RELOCATION OF EXISTING EQUIPMENT, VERIFY THE OPERATION AND WORKING FOR NEW HEATING, VENTILATING, AND AIR CONDITIONING EQUIPMENT. Ur Et CONDITION. 12. INSTALL STRAINERS ON SUPPLY SIDE OF EACH CONTROL VALVE, GAS PRESSURE REGULATOR, SOLENOID VALVE, AND ELSEWHERE AS INDICATED. 2. ROOFTOP UNITS SHALLSEQUENCE AND MODULATE ECONOMIZERS, COMPRESSORS, AND GAS Z >- 25. PROVIDE FIRE DAMPERS WHERE SHOWN ON THE DRAWINGS AND WHERE REQUIRED TO MAINTAINFIREDFURNACES TO MAINTAIN SPACE TEMPERATURE FROM PACKAGED CONTROLS. - Ce FIRE RATING OF WALLS. SEAL OPENINGS AROUND PENETRATION WITH FIRE DEPARTMENT 13. INSTALL DIELECTRIC FITTINGS (UNIONS AND FLANGES) WITH FERROUS AND BRASS OR BRONZE J a ft CO o APPROVED MATERIAL PROVIDE ACCESS TO ALL FIRE DAMPERS. END CONNECTIONS, SEPARATED BY INSULATING MATERIAL, WHERE PIPING OF DISSIMILAR METALS 3. ELECTRIC SPACE HEATERS TO BE PROVIDED WITH ALL NECESSARY CONTACTS AND RELAYS AND a0_ W N IS JOINED. CYCLED FROM LOCAL THERMOSTATS. a CV M 26. NEW EQUIPMENT (EXHAUST FANS) SHALLBE LOCATED ABOVE CEILING GRID SUCH THAT ALL V V- 1` 0 COMPONENTS REQUIRING MAINTENANCE ARE FULLY ACCESSIBLE. 14. INSTAII ALLVENT PIPING FOR GAS PRESSURE REGULATORS AND GAS TRAINS. EXTEND OUTSIDE 4. CONDUIT, WIRING, AND ACCESSORIES REQUIRED FOR THE INSTALLATION OF THE _ C) o BUILDING. AND VENT TO ATMOSPHERE. TERMINATE VENTS WITH TURNED-DOWN, REDUCING-ELBOW TEMPERATURE CONTROL SYSTEM, AS HEREIN SPECIFIED SHALL BE PROVIDED BY THE 27. IFA CONTRADICTION OCCURS IN THE CONTRACT DOCUMENTS, THE FOLLOWING ORDER OF FITTINGS WITH CORROSION-RESRANT INSECT SCREENS IN LARGE END. MECHANICAL TRADE UNLESS SPECIFICALLY SHOWN ON THE REQUIREMENTS OF ALL LOCAL AND 1 J Et °m DOCUMENTS SHALL BE USED: NATIONAL ELECTRIC CODES. 0 (B. HAS PREFERENCE OVER A. , C. HAS OVER B. , ETC. ETC.:) 15. INSTALLGAS PIPING NEXT TO EQUIPMENT AND APPLIANCES USING AS TO ALLOW SERVICE AND W < CO MAINTENANCE. 5. FURNISH & INSTALL ALL POWER & CONTROL WIRING REQUIRED FOR NEW AND RELOCATED2 _ o A. SMALL SCALE PLANS CONTROL WORK, CONNECT TO NEAREST AVAILABLE CIRCUITS AT PANELS AND PROVIDEV o B. ENLARGED SCALEPLANS 16. CONNECT GAS PIPING TO EQUIPMENT AND APPLIANCES USING HAS WITH SHUTOFF VALVES AND TRANSFORMERS, RELAYS, CONNECTORS, ETC, AS REQUIRED. PERFORM WIRING IN ACCORDANCE Z Et C. ELEVATIONS UNIONS. INSTALL GAS VALVE UPSTREAM FROM AND WITHIN 72 INCHES OF EACH APPUANCE WITH ELECTRICAL SPECIFICATIONS. W W Cl) Q D. DETAILS AND DIAGRAMS USING GAS. INSTALL UNION OR FLANGED CONNECTION DOWNSTREAM FROM VALVE. INCLUDE WI- E. SPECIFICATIONS FLEXIBLE CONNECTORS WHEN INDICATED. 6. THERMOSTATS TO BE KAPLAN STANDARD. THERMOSTATS SHALL BE TAMPER RESISTANT AND ZW SHALL BE ACCESSIBLE HEIGHT, PER ADA GUIDELINES. WHERE INSTALLED ADJACENT TO SWITCHES wF-- B 28. COORDINATE THE FOLLOWING ITEMS WITH THE BUILDING OWNER; OR SIMILAR DEVICES, THERMOSTATS AND SENSORS SHALL BE MOUNTED EVEN WITH ADJACENT 0 (9 O B. ALL CORING LI 0 ON MISCELLANEOUS PIPING WORK. COORDINATE WITH THE ARCHITECT FOR EXACT LOCATIONS AND CONDITIONS. 0 0 Et T- a 29. WORK OUTSIDE THE DEMISED SPACE SHALL BE SCHEDULED VIA WRITTEN NOTIFICATION TO THE 1. A/C CONDENSATE DRAIN PIPING SHALL BE TYPE DWV COPPER WITH SOLDERED DRAINAGE Q N OFFICE OF THE BUILDING AT LEAST 72 HOURS IN ADVANCE. FITTINGS OR GALVANIZED STEEL WITH SCREWED DRAINAGE FITTINGS, AS REQUIRED TO MATCH PIPING AND EQUIPMENT CONNECTIONS. PITCH PIPING 1/8" PER FT TO DRAIN TO FLOOR DRAIN. (9 PROVIDE CLEANOUT AT EACH CHANGE OF DIRECTION 90 DEGREES OR GREATER. i- 2. 2. REFRIGERANT PIPING SHALL BE TYPE K OR ACR COPPER. PIPING SIZES AND ARRANGEMENTS ISSUED / REVISED DATE SHALL BE PER MANUFACTURES RECOMMENDATIONS. DD SET 09/06/19 3. PROVIDE ADJUSTABLE HANGERS, INSERTS, BRACKETS, ROLLS, CLAMPS, SUPPLEMENTARY STEEL PERMIT SET 10/11/19 AND OTHER DEVICES REQUIRED FOR THE PROPER SUPPORT OF ALL PIPE LINES. HANGERS SHALL BE DESIGNED TO ALLOW FOR EXPANSION AND CONTRACTION OF PIPE LINES, AND SHALL BE OF ADEQUATE SIZE TO PERMIT COVERING TO RUN CONTINUOUSLY THROUGH HANGERS. SINGLE PIPE HANGERS SHALL BE ADJUSTABLE WROUGHT CLEVIS TYPE SIZED TO ALLOW FOR INSULATION WHERE REQUIRED. 4. REMOVE ALL BURRS AND BLOW PIPING CLEAR OF CHIPS BEFORE INSTAWNG PIPING. CLEAN AND FLUSH ALL NEW AND ADJACENT EXISTING PIPING BEFORE PUTTING INTO SERVICE. 5. TEST ALL NEW PIPING BEFORE INSULATING. REPAIR AND RETEST AS REQUIRED. A MECHANICAL SPECIFICATIONS .. M-OO1 COPYRIGHT ID 2019 CALLISONRTKL INC. 1 2 3 4 5 6 7 8 9 10 EXISTING ROOFTOP UNIT SCHEDULE FAN SCHEDULE AIR DEVICE SCHEDULE o GAS MANUFACTURER: LOREN COOK ESP MOTOR WEIGHT PLAN MANUFACTURER MODEL MATL. NECK FRAME PANEL REMARKS v Q MARK SIZE TYPE SIZE EER/ CBG HEAT MARK AREA SERVED MODEL CFM IN.W.G. SONES DRIVE RPM HP V/PH/HZ LBS. CONTROL REMARKS •r ' O.A. FAN MBH MBH ELECTRICAL Si TITUS OMNI ST. SCHED. LAY-!N 24"x24" 1,3,8 • Q [V MARK MFR MODEL NO. TONS SEER CFM CFM ESP HP TOT. SENS. IN/OUT MCA MOCP VOLT/PHASE REMARKS EF-1 RESTROOM 1 GC-148 75 0.5 2.0 DIRECT 937 36.0W 115/1/60 12 - 1,2 S2 TITUS FL-20 ST. SCHED. LAY-IN 48"x3" 1,5,6,7,8,9 .. U RTU-1 RHEEM RKNL-A060 5 13.0/- 2000 190 0.8 1.0 53 53 135/109.4 30 40 208/3 1,2 EF-2 RESTROOM 2 GC-148 75 0,5 2.0 DIRECT 937 36.0W 115/1/60 12 - 1,2 S3 TITUS 300RS ST. 10'x6" FLANGED 12'x8" 1,3,7,8 J RTU-2 WANE YSCO60 5 13.0/- 2000 380 0.8 1.0 53 53 80/64 27.4 40 208/3 1,2 EF-3 RESTROOM 3 GC-148 75 0.5 2.0 DIRECT 937 36.0W 115/1/60 12 - 1.2 S4 TITUS OMNI ST SCHED. FLANGED 12"x12" 1,3,7,8 E 4 2? 0- V F RTU-3 WANE YSC060 5 13.0/- 2000 260 0.8 1.0 53 53 80/64 27.4 40 208/3 1,2 EF-4 STORAGE GC-148 75 0.5 2.0 DIRECT 937 36.0W 115/1/60 12 1,2 - cn cn EF-5 IT CLOSET GC-186 200 0.5 4.0 DIRECT 1160 52 115/1/60 12 - 1,2,3 "x i 0" FLANGED 12"x 12" 8 (1) W G a� U T1 TITUS 355RL ST. 10 1. EXISTING ROOFTOP UNIT TO REMAIN. RE-BALANCE TO CFM SHOWN. CHECK PROPER OPERATION OF � c 1. PROVIDE WITH FACTORY SPEED CONTROLLER. UNIT, REPLACE EXISTING AIR FILTER, ANY WORN BELTS, AND SUPPLY FAN AND/OR CONDENSER R1 TITUS PAR ST. 22'x22" FLANGED 24"x24" 1,3,4,8 2. PROVIDE WITH FACTORY ALUMINUM CEILING GRILLE, STANDARD PLUG DISCONNECT, VIBRATION ISOLATION MOUNTING AND BACKDRAFT C L CONTACTORS (IF NECESSARY), LUBRICATE BEARINGS, CLEAN COILS, AND CHECK REFRIGERANT CHARGE. DAMPER. R2 TITUS PAR ST. 22"x22" LAY-IN 24"x24" 1,3,4,8 . (f) LU VERIFY EXACT SPECS, LOCATION, AND PROPER OPERATION WITH LANDLORD REPRESENTATIVE. 3. EXHAUST FAN TO BE CONTROLLED BY THERMOSTAT. O w W 1. AIR DEVICE RUN-OUT SHALL BE SAME SIZE AS DIFFUSER NECK. z Z o cc 2. VERIFY EXISTING ELECTRICAL WITH ELECTRICAL CONTRACTOR. 2. PROVIDE OPPOSED BLADE VOLUME DAMPER. ��� Q 3. NC<30. • 0 4. PROVIDE WITH BALANCING DAMPER. 5. PROVIDE (1) 3" WIDE SLOT. 6. PROVIDE WITH INSULATED PLENUM BOX. SEAL 7. PROVIDE WITH NECK MOUNTED OPPOSED BLADE DAMPER, ADJUSTIBLE FROM FACE, FIELD INSTALL. DIFFUSER NECK MECHANICAL KEYED NOTES 8. DIFFUSER SHALL BE WHITE TO MATCH CEILING UNLESS OTHERWISE NOTED. 9. PROVIDE WITH BOWDEN CABLE CONTROL SYSTEM OR EQUIVALENT SIZE SCHEDULE �.. O1 FUNISH AND INSTALL GALVANIZED STEEL DUCTWORK, SIZES AS NOTED ON PLANS. 4' 3-4- `` , NECK DUCTWORK SIZES NOTED ARE SHEET METAL SIZES, DUCTWORK TO BE EXTERNALLY I I I I " -. ;M' ,�' CFM WRAPPED WITH 1-1/2" INSULATION AND VAPOR BARRIER. , ...6=9 A;. SIZE I 5'3"-;P ce I I I f I I I 1;t,:,t 6"0 0 - 140 O MAXIMUM FIVE (5) FEET OF FLEXIBLE DUCT. ONLY ONE 90 DEG. ELBOW ALLOWED IN FLEXIBLE DUCTWORK. R2 I R2 /R2\ R2 p E 8"0 150 - 250 O3 PROVIDE 7-DAY PROGRAMMABLE THERMOSTAT WITH AUTO CHANGEOVER AND , �' 4,4 10"� 260 - 400 RELATED WIRING TO CONTROL ROOFTOP UNITS. MOUNT AT 60" AFF. T r 200 �- y I 125 I \125/ 125 p O EXISTING ROOFTOP UNITS (RT11-1,2,3), TO REMAIN. VERIFY EXACT LOCATION AND -la 12"� 410 - 600 i EXPIRATION DA,fE E2.131.20M,; PROPER WORKING CONDITION IN THE FIELD. 125 � I 10/11/2019 © ❑ I ❑ I ( C 14"0 610 - 1000 5 FURNISH AND INSTALL CEILING MOUNTED EXHAUST FAN, (EF-1,2,3,4). EXTEND 6"0 I0 t DUCTS FROM EACH CEILING EXHAUST FAN TO 10" EXHAUST DUCT THROUGH ROOF. -- . -. - 16'0 1010 - 1400 S1 - --0 _ - I V O FURNISH AND INSTALL CEILING MOUNTED EXHAUST FAN, (EF-5). EXTEND 8"0 DUCT (100 S1 - _ $ 18"0 1410 - 1900 FROM CEILING EXHAUST FAN THROUGH ROOF. 4 ® S) �� S) S14 [ Sl ,,,,,,, 200 100 .:,..:r . 125 125 125 S1 ( 12 O7 10` EXHAUST DUCT THROUGH ROOF. PROVIDE WITH ROOF CAP. VERIFY A MINIMUM >a< i / / � o 10'-0" CLEARANCE FROM ALL OUTSIDE AIR INTAKES. 9 T1 Ti T -1J-1,2,3 f')I TYPICAL f 1100/ = z T -I( I 8 8 EXHAUST DUCT THROUGH ROOF. PROVIDE WITH ROOF CAP. VERIFY A MINIMUM I -- I f 1 I I / I I •L 10'-0" CLEARANCE FROM ALL OUTSIDE AIR INTAKES. , 12x12 j I 16x12 I 12x12 / I I /I AS 6 9 FURNISH AND INSTALL REMOTE TEMPERATURE SENSOR AND CONNECT TO THERMOSTAT Iii t/-vv ��-+ I vA4.., 50 . oOUNT ON wALL AT 48" AFF. MULTIPLE SENSORS TO BE AVERAGED. ITL I I D �1V" [ O O I © I = 1v."F.',' Q PROVIDE INSULATED BASE FOR SENSORS ON EXTERIOR WALLS. IR ._- / 1 I t / I I I I ' _ •� q nx,z 1. ._..... I 1 1? 1 �F''. / �,}(g� ! _.., I _ 0 [ I I - I 1 I L- I1111 _ -� S1 (R12/))/R-U-2 S4 0 Ifj .1 11 T \100 So 300 50 , I ly 0 1�� _IN N s4 w -,,/� ._.J� -.___.__ _4_N I A g t' r • 50 I o ) ( I. S1 , S1 J I 10"0 I 6"0 J I�\ 1 0 Si 125 �_1 _ "' 125 a .. '� 250 I 'c ! O cc c R2 54 igi< > ;zf0êi"I IIII _ J H i® - ry- 2...' 1 R2 EF Q� i I_ --(-RT) lAnk 0 Q 125 j 3 © v i , E 125 125 V v I 51 ) I Iel ; 200 � r �- - Et MECHANICAL SYMBOLS LEGEND . ® _ TWA O THERMOSTAT S1 _.. R2 ® I 0 0 III o 200 - A � ,IW- FLEXIBLE DUCT Xs) I 250 250 -.. _ s'Xilt- T le w Q � I S1 4 VOLUME DAMPER S2X04 I Z II � ' 1 .._� 1254, - - i_ - _ J M Q FD FlRE DAMPER 400 IIIIIL�II�I��II1�1�-,II® , I ._.... i R2 I I!Z� a O W N o� - R - 200 LL ti in 111 CEILING SUPPLY AIR DIFFUSER k� a ,)f(1 _-- W......__ ; 0 _f 11cf) T . ..__ N911 j ---V ' '"'-q 1`Rll�Punli 7i iRmAlll. 11 A Ill-+11111111 I - '; -.- ..�-^--__ \ J IV� CEILING RETURN AIR GRILLE (, ( I - j t ` W SI 0 ' SIDEWALL AIR DIFFUSER OR GRILLE - zOx 4 200 TYPICAL 1 o O ❑ I®� = Io NEW DUCTWORK I I I I I I t_ I- '1 i_ 1 :®1 Z U �/ k I - ? I - W LLI Cl) EXISTING DUCTWORK I I 14x12 20x1I / 0 LLI (] U - CD I CONDENSATE DRAIN 11111111111111.1 - er I ZL (nB GAS PIPING p V " " Q U D PIPE TURNING DOWNCC IJ I . I Co 5 ® R1 ® - RTU 3 2Ox1 1 T - O.. Q 400 S I EF 5 Q N �O PIPE TURNING UP 200 --4 BALL VALVE ox` (600) 11 I -' I u I I I I I r n . N V GATE VALVE RTU-1 00 I RTL)-1 00 RTU-3 ,(_S_)(9) Alik OE- - Vil H e CONNECTION OF NEW TO EXISTING 0 TYPICAL ] _ MITREVISED -NH CHECK VALVEIIIIIIIIIIIIIIII ISSUED 1DATE I DD SET 09/06/19 -15- GAS COCK00 l / ' A i PERMIT SET 10/11/19 -III- UNION (7) R2 I , I R2 O PRESSURE GAUGE ` 275 ® 275 11) STRAINER .I 12x10 I I 0 TYPICAL I AFF ABOVE FINISHED FLOOR E - _ -_ 4 ❑M MOTORIZED DAMPER O 0 0 )--41-11 I I4 S1 AIR DEVICE # S - SUPPLY ' \ X) A 100 CFM E - EXHAUST la Ca .+r- ` Al S1 / S1 ' Si I �` ' 40n 400 150 Wil_... I 275 275 is I . , I It lI _I it it )t IL Ji it t: )I NORTH MECHANICAL MECHANICAL FLOOR PLAN /, PLAN SCALE: 1 /4" = 1 '-O" VII, M-101 COPYRIGHT 0 2019 CALLISONRTKL INC. 1 2 3 4 5 6 7 8 9 10 Emmi CO ' LT o Vp -0 'cr •— OC c rn N _ Q F E a � V -- U N . L- '3 W c Ctil w � � w W c z ZM co •i• 0 - co • SEAL 4,,(3*-- 4, mak, , 44 52821PE oz 1 414 CO"3 1. & '41441. 11.0s0** ' 1 EXPIRATION DATE:flJ 3I 2otg 10/11/2019 • V 5020CC ROUND DAMPER OR 830ACC RECTANGULAR - -= 2 P OPPOSED BLADE DAMPER C4 en N RIGID DUCTWORK FLEXIBLE DUCTWORK E.wz L °x (A(*) .....v/ _. 01 CD --ALL- 6.01 AIL , - •� how v) ---; 11111111111111"1 W -, . C J FLEXIBLE CASING 11111111110100 A Y AND WIRE (50'-0" 1 Z MAXIMUM) -_z _m1 . / < (---- -/-'- X Y LOCKING F" RACK & PINION O w c \(( 7 (j -,-. t1'."4 OPERATOR Zce o OUNTING BRACKET Jmil O - Ni L H ca 1) CABLE SHALL CONSIST OF BOWDEN CABLE 0.054" J STAINLESS STEEL CONTROL WIRE ENCAPSULATED IN ' a 1/16" FLEXIBLE GALVANIZED SPIRAL WIRE SHEATH. �� V v 2) LOCKING RACK AND PINION GEAR DRIVE SHALL BE CONSTRUCTED OF 14 GAUGE STEEL AND SHALL BE �- LINEAR SLOT DIFFUSER C USED TO CONVERT ROTARY MOTION INTO PUSH-PULL WITH PLENUM BOX CeMOTION. I- 3) CONTROL SHAFT SHALL BE "D"-STYLE FLATTENED SOCKET WRENCH 01/4" DIAMETER WITH 265' ROTATION PROVIDED �, 1-1/2" LINEAR TRAVEL CAPABILITY. r () TRANSITION BOWDEN CABLE CONTROL SYSTEMe. C o TO BRANCH NO SCALE N o SIZE / a W N c al RADIUS ELBOW v O LL' ti to (n (n O 1 W }. J O °' • Q O e MI* 1.5D 2 2 - o0 FULL DEPTH OF 15 DE 3 Z 0 w MAIN DUCT W (I) BRANCH 3 g' X W Q DUCT Z W C' U 1 W1 X D1 = Al O CO i- g TRANSITION 0 TO BRANCH 1 RADIUS ELBOW 1 D a O 0 SQUARE VANEQ SIZE ELBOW BRANCH DUCT "B" co d D ./ 1.5D MI I Q N TURNING VANES y W2 X D2 = A2 BRANCH DUCT,SEE D x W () e ii30 DEC BD © / I TAKE-OFF DETAIL = — I- BD I— r-- r CJ l ISSUED / REVISED DATE BRANCH 1 J 1/4- �-I -• SEE NOTE 2 - _D x W� DUCT FULL DEPTH OF J DD SET 09/06/19 1 J I I PERMIT SET 10/11/19 MAIN DUCT J '- I I J J 1.--' .1 1. T.S.P. OF FAN PLUS 1" WATER N. j$ANSITIONS `-� W3 X D2 = A3 J 1 FLOW o J FULL 0 OF o W5 X D3 = A5C W4 x D2 = A4 / J EQUIPMENT NT ABOVE EQUIPMENT J CONNECTION 2. SLOPE PIPE MINIMUM 1% `n BRANCH DUCT "A" CONNECTION 3. TERMINATE CONDENSATE DRAIN WITH �! NOTES; / � � 1. DETAIL IS APPLICABLE TO SUPPLY L N. AIR BRANCH DUCT TAKE-OFFS. TURNING VANES C.O. COONH<5E IMAX. C.O. MINIMUM 2" AIR GAP AT ROOF SQUARE ELBOW . . DRAIN, GUTTER, OR FLOOR DRAIN L BRANCH DUCT n TRANSMON FROM W1 X D1 TO W2 X D2 NOTES; 25' APART _ Dili . OMIT TRAP ON EQUIPMENT WITH SIDE TAP 1. UNLESS SPECIFICALLY NOTED OTHERWISE, DETAIL Mg 1111i INTERNAL TRAP, SEE I.O.M. A a2 FOR UNEQUAL BRANCH DUCTS, TRANSITION TO APPLIES TO ALL SUPPLY, ALL EXHAUST, AND ALL BRANCH DUCT SIZE RETURN AIR ELBOWS. MIN. 2" AIR5. PIPE INSTALLATION SHALL PROVIDE 2. BRANCH DUCT TAKE-OFFS MUST BE A MINIMUM OF GAP _ NOTE 1 SERVICE ACCESS TO EQUIPMENT 4D DOWNSTREAM OF EITHER TYPE OF ELBOW, AND NOT .1 AND TO TRAP. LESS THAN 3D UPSTREAM. EQUIPMENT CABINET- MECHANICAL 6 INSULATE PIPE ON BUILDING INTERIOR AS SPECIFIED. DETAILS ..0. BRANCH DUCT TAKEOFFS AND TRANSITIONS . . DUCT TEE FITTING DUCT ELBOW . . . AC EQUIPMENT CONDENSATE DETAIL - NO SCALE NO SCALE NO SCALE NO SCALE lvi-3 01 COPYRIGHT 0 2019 CALLISONRTKL INC.