Plans (146) F PS2020-00007 ., ,414.100. 04, OFFICE COPY 000•1��'" ,� o�CITY OF TIGARD IA REVIEWED FOR CODE COMPLIANCE . ..mi"IlliW ,0�Approvcd .J jzo so •OTC: [ ] 0 oX Qac 'Permit II: P � " cam(»7 0 ■ n Controls Address:state #: , , \J (.,,1('Com,,, RECEIVED w. / 00,s Br Date: j -2,,,ic- Co40.0 v o.. • 2 O oI_JOO ,--1 Ls.. U DRAWING INDEX LEGENDS APPLICABLE CODES & STANDARDS JOHNSON CONTROLS CONTACTS ,_ ,,,,c, `A' Fri JURISDICTIONS WITHIN THE STATE MAY HAVE AMENDMENTS TO THE STATE ADOPTED CODE CHECK Sales Representative Drawings Prepared By WITH THE LOCAL JURISDICTION AUTHORITY FOR MORE DETAILS. Oregon Structural Specialty Code,2019 Edition BRYAN ADAMS LUCAS CONEDERA BRYAN.ADAMS@JCI.COM LUCAS.CONEDERA@JCI.COM FIRE ALARM SYMBOL LEGEND PHONE:503-683-9000 PHONE:503-683-9000 SEAN MALLON Oregon Fire Code,2014 Edition SYMBOL I DESCRIPTION BRAND I MODEL Isox CODE WIRE LICENSE#5189LEATYPE Oregon Mechanical Specialty Code,2019 Edition V EXPIRES 10/01/2020 PANELS 8 ANNUNCIATORS Scheduling Drawings Reviewed By Oregon Electrical Specialty Code,2017 Edition KART BURGESS JOHN HABER si . . NACU 14009 IDNET NAC EXTENDER PANEL BEIGE,120 VAC SIMPLEX I 4009-9201 IMFG1 KARI.BURGESS@JCI.COM JOHN.HABER@JCI.COM Sheet List Table National Fire Alarm Code(NFPA 72),2013 Edition PHONE:503-683-9000 PHONE:503-683-9000 Sheet Number Sheet Title INITIATING DEVICES NICET LEVEL III#127144 FA-001 COVER SHEET F MANUAL PULL STATION SIMPLEX 4099-9001 1 E M FA-101 DEVICE PLACEMENT PLAN,CALCULATIONS AND WIRING TYPICALS 0 ADDRESSABLE PHOTOELECTRIC SMOKE SENSOR SIMPLEX 4098-9714 HEAD 4K M lJ WITH STANDARD BASE 4098-9792 BASE 1C NOTIFICATION APPLIANCES 1�C MULTI-CANDELA HORN/STROBE,CEILING MOUNT, SIMPLEX 4906-9130 4A V WHITE,FIRE,CLEAR LENS 1B Irl STROBE,CEILING MOUNT,WHITE,FIRE,CLEAR LENS SIMPLEX 4906-9104 1 E V OCCUPANCY TYPE(S): SPRINKLER PROTECTION: C HB B BUSINESS GROUP BUILDING IS FULLY SPRINKLED MISCELLANEOUS DEVICES EOLR IEND-OF-LINE RESISTOR 10K(EOL) SIMPLEX I 4081-9008 I I BACKBOX CODES SCOPE OF WORK PROJECT DIRECTORY CODE 1 BOX SPECIFICATIONS CODE 1 BOX SPECIFICATIONS 4A 14"SQ.BOX 1 1/2"DEEP IE !SINGLE GANG BOX 2 1/2"DEEP MODIFY EXISTING FIRE ALARM SYSTEM: PROVIDE NEW DEVICES AND RELOCATE EXISTING DEVICES AS SHOWN ON DRAWINGS. Site Johnson Controls District-448 4B 4"SQ.BOX 1 1/2"DEEP W/COVER 1F SINGLE GANG BOX 2 1/2"DEEP W/COVER 4C 4"SQ.BOX 1 1/2"DEEP W/1 1/2"EXT.RING 1G SINGLE GANG BOX 2 3/4"DEEP ALL NEW WIRING TO BE CLASS B. L1 VARIANT SUITE 308 4D 4"SQ.BOX 21/8"DEEP 1H SINGLE GANG BOX 31/2"DEEP 10300 SW GREENBURG RD 6305 SW ROSEWOOD ST,SUITE A 4E 14"SQ.BOX 2 1/8"DEEP W/COVER 2A DOUBLE GANG BOX 2"DEEP THE EXISTING FIRE ALARM SYSTEM SHALL NOT BE DISCONNECTED OR TAKEN OUT OF SERVICE WITHOUT WRITTEN PERMISSION FROM THE OWNER. IT TIGARD,OR 97223 PHONE:LAKOOR 97035 503-683-9000 4F 14"SQ.BOX 2 1/8"DEEP W/1 1/2"EXT.RING 2B TWO GANG BOX 2 1/2"DEEP IS THE CONTRACTOR'S RESPONSIBILITY TO COORDINATE WITH THE OWNER THE TIMING OF ANY EXISTING FIRE ALARM SYSTEM DEMOLITION WORK. FAX: 503-675-6521 4G 14"SQ.BOX 2 1/8"DEEP W/SINGLE GANG COVER 2C TWO GANG BOX 2 3/4"DEEP SERVICE:503-683-9001 4H 14"SQ.BOX 21/8"DEEP W/TWO GANG COVER 5A 15 GANG BOX 21/2"DEEP 4J 4"SQ.BOX 2 1/2"DEEP 6A 6 SINGLE GANG BOXES 3 1/2"DEEP I Installer 4K 4"OCT.BOX 1 1/2"DEEP 6B 6 GANG BOX I 4L 4"OCT.BOX 1 1/2"DEEP W/1 1/2"EXT.RING 6C 16 GANG BOX 21/2"DEEP I POINT MONITOR CORPORATION 4M 411/16"SQ.BOX 2 1/8"DEEP 6D 6 GANG BOX 31/2"DEEP ► DESIGN STATEMENT 5863 LAKEVIEW BLVD STE 100 LAKE OSWEGO,OR 97035 T,--r �+r 4N 411/16"SQ.BOX 1 1/2"DEEP W/1 1/2"EXT.RING FBO FURNISHED BY OTHERS ;�' £ '$' �' s- -�# �� DESIGN IS FOR THE RELOCATION OF EXISTING NOTIFICATION DEVICES AND INSTALLATION OF NEW NOTIFICATION DEVICES IN THE LINCOLN 1 SUITE 308 AS SHOWN ON `` c. r r F'H IT 4P 411/16"SQ.BOX21/8"DEEP W/1 1/2"EXT.RING MFG SUPPLIED BY MANUFACTURER THE ISSI;�,,N.. OFA . 4Q 4"SQ.BOX 1 1/2"DEEP W/4098-9832 ADAPTER MDW MOUNTS TO DUCTWORK I FLOOR PLAN. BASED ON CO; SI i F;JCTION O 4R 4"SQ.BOX 1 1/2"DEEP W/RACO 787 OR EQUIV. MBD MOUNTS IN BOX BEHIND DETECTOR DOCUMENTS AND OTHER a 4S 4"SQ.BOX 1 1/2"DEEP W/4098-9863 ADAPTER WM WALL MOUNT DATA SHALL NOT PREVENT 1A SINGLE GANG BOX 1 1/2"DEEP DT DESK TOP MOUNT THE CODE CFFiCIAL FRONT PLEASE PROVIDE `: lB SINGLE GANG BOX 2"DEEP DS REFER TO PRODUCT DATASHEET I REQUIRING THE CORRECTION COMPLETED NFPA 12 O IC SINGLE GANG BOX 21/8"DEEP NR NO BACKBOX REQUIRED I OF ERRORS. OSSC 105.4 RECORD OF 0 1D SINGLE GANG BOX 21/8"DEEP W/COVER TRM 3.5"WIDE SNAP TRACK W/MOUNTING SCREWS I COMPLETION AT co FOR ADDITIONAL BACK BOX OPTIONS,REFER TO THE XX-700 SERIES DRAWINGS OR PRODUCT DATA SHEETS AND FINAL INSPECTION o INSTALLATION INSTRUCTIONS. �y.� NOTE:EXISTING DEVICES SHOWN SHADED.NEW AND RELOCATED DEVICES SHOWN BOLD. ABBREVIATIONS LEGEND DEVICE TAG LEGEND o in M .03 AC = ABOVE CEILING NEC = NATIONAL ELECTRIC CODE AFF = ABOVE FINISHED FLOOR NFPA = NATIONAL FIRE PROTECTION ASSOCIATION W AHJ = AUTHORITY HAVING JURISDICTION NIC = NOT IN CONTRACT 0 ALM = ALARM NPU = NETWORK PROCESSING UNIT II ANN = ANNUNCIATOR NTS = NOT TO SCALE a BMS = BUILDING MANAGEMENT SYSTEM PAP = PRE-ACTION PANEL ADDRESSABLE CARD (IDNET OR MAPNET) r DEVICE ADDRESS 8 - C = CEILING MOUNTED RC = EXISTING TO REMOVE AND COVER CD = CANDELA RATING RD = EXISTING DEVICE TO BE RELOCATED a, DET = DETECTOR RL= RELOCATED DEVICE M2- a) _ ' DGP = DATA GATHERING PANEL RR = REMOVE EXISTING&REPLACE WITH NEW ' V E = EXISTING TO REMAIN SCC = STATUS COMMAND CENTER ADDRESSABLE DEVICES NUMBERING Im o EOL= END OF LINE SLC = SIGNALING LINE CIRCUIT ACCEPTABLE CABLE EPO = EMERGENCY POWER OFF SMK = SMOKE M FIRE ALARM WIRE LIST TYPES FAA = FIRE ALARM CANNUNCIATOR TROLPAN SUPV = SUPERVISORY FACP = FIRE ALARM CONTROL PANEL TAC = TRUEALERT ADDRESSABLE CONTROLLER ca o FATC = FIRE ALARM TERMINAL CABINET TRBL= TROUBLE a cea z Z 0 FBO = FURNISHED BY OTHERS TS= TAMPER SWITCH Ce CI 05 CIRCUIT DESCRIPTION CONSTRUCTION GAUGE CIRCUIT PROPERTIES e e = ± is - FCC = FIRE COMMAND CENTER TYP = TYPICAL -CIRCUIT DESIGNATOR Ce LL LL ~ ~ O 6 FSD = FIRE SMOKE DAMPER UON = UNLESS OTHERWISE NOTED 4009 NAC PANEL 0) V I VISUAL SIGNAL 2 COND.SOLID 14 AWG X X X X FTR = FIRE ALARM TRANSPONDER VCC = VOICE COMMAND CENTER -7 00 0,> H = HIGH HUMIDITY VT = VALVE TAMPER r- DEVICE DESIGNATOR O L. o CONDUIT SIZE MAX CONDUCTOR AREA CONDUIT SIZE MAX CONDUCTOR AREA NOTES HT = HEIGHT W = WATTAGE M = Lu 1/2" 0.122 SQ INCH* 1-1/4" 0.598 SQ INCH* SUBSCRIPT"u":UNSHIELDED CABLES HVAC = HEATING VENTILATION&AIR CONDITIONING W/= WITH N 14-1 Rr- LLJ CCI co) 3/4" 0.213 SQ INCH* 1-1/2" 0.814 SQ INCH* MIXED WITH SHIELDED CABLES OF IMS = INFORMATION MANAGEMENT SYSTEM W/0 = WITHOUT H Z N 'a 1" 0.346 SQ INCH* 2" 1.342 SQ INCH* SAME CIRCUIT DESIGNATION. MAX = MAXIMUM WF = WATERFLOW VISUAL. AUDIBLE OR A/V DEVICE Z W0_ rnw ti w MIN = MINIMUM WG = WIRE GUARD o *40%FILL PER N.E.C. STP=SHIELDED TWISTED PAIR N/A = NOT APPLICABLE WP = WEATHERPROOF -OUTDOOR AERIAL CABLE REQUIRES MESSENGER UTP=UNSHIELDED TWISTED PAIR NAC = NOTIFICATION APPLIANCE CIRCUIT XP = EXPLOSION PROOF H 0 Et cITEMS SUCH AS CAPACITANCE BETWEEN CONDUCTORS AND WIRE GAUGE CAN BE CRUCIAL TO THE CIRCUIT DESIGN OF NDU = NETWORK DISPLAY UNIT 0Z 0 THIS SYSTEM INSTALLATION.THE INSTALLING CONTRACTOR IS RESPONSIBLE FOR SELECTING AND INSTALLING CABLE Q • MANUFACTURER AND MODEL THAT MEETS OR EXCEEDS THE ABOVE REQUIREMENTS.RECOMMENDED CABLE SYSTEM SEQUENCE OF OPERATIONS co 6 O 0 MANUFACTURERS AND MODEL NUMBERS ARE AVAILABLE UPON REQUEST. ce Z a OQ coL J _1 o I- U TD 2 E I- Q N d 41 w J_ Ll 3 3 C 0 I CONTROL UNIT ANNUNCIATION NOTIFICATION I FIRE SAFELY CONTROL I N O� o '`OQ` �e0� O ,`P� P ��O\ SGP �O� G' \c,, X05,\N- .\,:?, 0�5 J�5 �p\c, �V v�P�v�O �O�GP c\V `'� � rx J��'\40 Q< 0��� J�Q O�P� O�-1 OQ��S�G \O\\Q. JNi, Q,�O� SJR�JQ�,`O"J cp O0 �\' �� `Qcr � GENERAL NOTES TYPICAL RISER DIAGRAM ���������� `'JO���<y��P�P�QGJ 4o .`O#, ��- �O° 4,, ,_,,Q. <,„ w �5 QQ 5J �J �Q `Q� �P� �O� v� c,G � `' GPS• tQ� P �# � �� y P 1. THESE DRAWINGS DEPICT GENERAL LOCATIONS OF LIFE SAFETY EQUIPMENT&FIELD DEVICES.EXACT ROUTING OF CONDUITS IS TO BE RISER NOTES: 5 O �0 5 F. O Si)0 O �, O �. O �' OQ PJ �`� J J0� P J ��� 00 ` �� Q� DETERMINED IN THE FIELD BY THE INSTALLING CONTRACTOR TO SUIT CONDITIONS. ALL CHANGES SHALL BE CLEARLY INDICATED ON �0 �O 0 Q O �, �, O ��, O� •JO O� JO O� JO Q N.' �j c,J �Q� �, d� s)## �j• O } THE RECORD DRAWINGS. 1. RISER IS A DIAGRAMMATICAL REPRESENTATION OF THE 0 Q 0 P 0 e r F' �,0 k,('OZ- 00 �F. Oct . Q 5 ��1 CO 2. SHOULD ANY CONDITIONS EXIST THAT DIFFER FROM WHAT IS INDICATED ON THESE DRAWINGS WHICH CAUSE MAJOR DEVIATIONS IN SYSTEM ARCHITECTURE IN BUILDING CROSS SECTION.IT IS P� P� P� P� P� P� Q�•�' Q�J M � # GPSw�, c' �'o THE WORK SHOWN,THE CONTRACTOR SHALL CONTACT JOHNSON CONTROLS INA TIMELY MANNER SO AS NOT TO IMPAIR THE NOT INTENDED TO REPRESENT ACTUAL WIRE RUNS, PANEL G� QIN GAJ G� G� G� G� G� G� ��?' ��`��P�� `����P ,Q 9- aCONSTRUCTION SCHEDULE. CONFIGURATIONS OR PENETRATIONS.REFER TO FLOOR SYSTEM INPUTS P P P P P P P P P `� Q` 4 P �. F I c AA B C D E F G H I J K L M N 0 P Q R S T U V W X Y Z AA AB AC AD AE AF AG AH Al Al REMARKS 3. CONTRACTOR IS RESPONSIBLE FOR MAKING AND OBTAINING APPROVAL FOR ALL NECESSARY ADJUSTMENTS IN CIRCUITING AS PLANS AND PANEL DETAILS FOR CIRCUIT ROUTING AND1 SMOKE SENSOR/DETECTOR 1 zo REQUIRED TO ACCOMMODATE THE RELOCATION OF EQUIPMENT AND/OR DEVICES WHICH ARE AFFECTED BY ANY AUTHORIZED CHANGE. CONFIGURATION INFORMATION. 2 MANUAL PULL STATION • • • • • • • • • 2 a ALL CHANGES SHALL BE CLEARLY INDICATED ON THE RECORD DRAWINGS. 2. ALL WIRING SHALL COMPLY WITH APPLICABLE ELECTRICAL 3 DUCT SENSOR/DETECTOR • • • • • • • • 3 R 4. A STAMPED SET OF APPROVED FIRE ALARM DRAWINGS SHALL BE AT THE JOB SITE AND SHALL BE USED FOR INSTALLATION. CODES.REFER TO'APPLICABLE CODES&STANDARDS'ON 4 MAIN FLR. ELEV. LOBBY SMOKE DETECTOR • • • • • • • • • • • • • 4 o 5. THE POWER CIRCUIT TO THE FACP AND TO THE FIRE ALARM POWER SUPPLIES SHALL BE ON A DEDICATED 120V,20A BRANCH CIRCUIT SHEET FA-001 FOR SPECIFIC CODE REFERENCES. 5 ELEVATOR LOBBY SMOKE DETECTORS (EXC. MAIN FLR.) • • • • • • • • • • • • • 5 BREAKER,AND SHALL HAVE A RED MARKING,LOCK-ON PROVISION AND SHALL BE IDENTIFIED AS"FIRE ALARM CIRCUIT CONTROL." THE 3. DEVICES ARE TYPICAL.SEE FLOOR PLAN FOR QUANTITY& 6 ELEVATOR MECH. ROOM HEAT DETECTOR • • • • • • • • • • • • 6 = LOCATION OF THE CIRCUIT DISCONNECT MEANS(CIRCUIT BREAKER)SHALL BE PERMANENTLY IDENTIFIED AT THE FIRE ALARM CONTROL LOCATIONS. 7 ELEVATOR MECH. ROOM SMOKE DETECTOR • • • • • • • • • • • • 7 C-' UNIT. 4. EXISTING DEVICES SHOWN SHADED.NEW AND RELOCATED 8 ELEVATOR SHAFT HEAT DETECTOR • • • • • • • • • • • • 8 0 6. UPDATE THE AS-BUILT DRAWING SET DAILY WITH JOB PROGRESS. RETURN THE AS-BUILT DRAWING SET TO JOHNSON CONTROLS NO DEVICES SHOWN BOLD. 9 ELEVATOR SHAFT SMOKE DETECTOR • • • • • • • • • • • 9 LATER THAN 7 DAYS AFTER FINAL TEST. 10 ELEVATOR POWER MONITOR • • • • • • • 10 I 7. THE CONTRACTOR WILL MAINTAIN ALL AREAS OF THE BUILDING INA NEAT AND WORKMANLIKE MANNER. KEYED NOTES:REPRESENTATIVE. 11 FIRE ALARM AC POWER FAILURE • • • • • • • 11 w 8. DO NOT APPLY POWER EXCEPT IN THE PRESENCE OF A FACTORY TRAINED JOHNSON CONTROLS TECHNICAL a co 9. ANY SMOKE DETECTOR HEAD INSTALLED BEFORE THE BUILDING IS CLEANED AND ACCEPTED SHALL BE COVERED TO PROTECT FROM O MODIFY EXISTING NOTIFICATION CIRCUIT N10 AND 13 OPEN CIRCUIT OR GROUND FAULT • • • • • 13 c:5 0 N DUST. ANY FALSE ALARMS DUE TO DIRT CONTAMINATED HEADS SHALL BE THE RESPONSIBILITY OF THE FIRE ALARM INSTALLER. 14 CLASS B NOTIFICATION CIRCUIT (NAC) - SHORT • • • • • 14 w Y 0 10. THE FIRE ALARM INSTALLER WILL MAINTAIN THE FIRE RESISTANCE INTEGRITY OF ALL WALL,CEILING,AND ROOF ASSEMBLIES ANY TIME RELOCATE EXISTING NOTIFICATION DEVICES AS SHOWN � Ce N THAT WORK IS NOT ACTIVELY BEING PERFORMED. ON FA 101.MAINTAIN SUPERVISION. 15 15 co a 0 16 16 • 11. INSTALLATION OF DEVICES SHALL BE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. POWER LIMITED AND NON POWER 17 17 ISUBMITTAL LIMITED FIELD WIRING MUST BE INSTALLED WITHIN THE FACP ENCLOSURE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND V 18 18 I APPLICABLE ELECTRICAL CODES.REFER TO'APPLICABLE CODES&STANDARDS'FOR SPECIFIC CODE REFERENCES. 19 19 I 0 12 . ALL WIRING SHALL BE INSTALLED ACCORDING TO APPLICABLE ELECTRICAL CODES. SPARE Ni2 20 20 I- V DRAWN BY: L.CONEDERA z 13. FIRE ALARM CIRCUITS SHALL BE IDENTIFIED IN ACCORDANCE WITH APPLICABLE ELECTRICAL CODES. MARK ALL FIRE ALARM WIRES IN (RL) 1 V1 21 21 CHECKED BY: J.HABER a ACCORDANCE WITH APPLICABLE ELECTRICAL CODE SECTIONS FOR POWER LIMITED AND NON-POWER LIMITED WIRE. (N10�(RL) (RL) V O SPARE o N11 I /, 22 2/ g14 FIRE ALARM CABLE INSTALLED IN DUCTS,PLENUM,AND OTHER SPACES USED FOR ENVIRONMENTAL AIR SHALL BE TYPE FPLP. EOLR �-� N10 I Vl1 23 23 ISSUE DATE: 1/13/20 15. FIRE ALARM CABLE INSTALLED IN THE VERTICAL RUNS AND PENETRATING MORE THAN ONE FLOOR OR CABLES INSTALLED IN VERTICAL 24 24 JOB#: RUNS IN SHAFTS SHALL BE TYPE FPLR. V 25 25 PROJECT* 448:616912101 16. FIRE ALARM CABLE INSTALLED IN UNDERGROUND CONDUIT OR OTHER WET LOCATIONS SHALL BE UL LISTED FOR WET LOCATIONS. (N9) Ny 9 26 26 EOLR ) 5 5-1)71-5 r5--� 1� JOHNSON CONTROLS©2020 17. FIRE ALARM CIRCUITS EXTENDING BEYOND ONE BUILDING AND RUN OUTDOORS SHALL BE INSTALLED IN ACCORDANCE APPLICABLE27 27 ELECTRICAL CODES,WHERE APPLICABLE. V L 120 VAC 28 28 SYSTEM: 18. ALL WIRING,INCLUDING SHIELDS MUST BE DRY AND FREE OF SHORTS AND GROUNDS. 29 29 FIRE ALARM SYSTEM 19. ALL SHIELDED WIRE MUST HAVE SHIELD CONTINUITY AT FULL LENGTH OF THE WIRE. 30 30 20. ONLY SYSTEM WIRING CAN BE RUN IN THE SAME CONDUIT. 31 31 I SHEET: 21. 120VAC IS NOT PERMITTED IN THE SAME CONDUIT WITH LOW VOLTAGE WIRING. 32 32 I 22. MAINTAIN MAXIMUM CONDUIT FILL RATIO AS PER APPLICABLE ELECTRICAL CODES REQUIREMENTS. ABCDEF CH I JK L MNOPQR S TUVWX Y Z AA AB AC AD AE AF AG AH AI AJ 23. EXISTING CONDUITS MAY BE USED BY THE INSTALLATION CONTRACTOR AS DEEMED NECESSARY;HOWEVER,ANY EXISTING CONDUIT COVER SHEET WILL BE USED ONLY IF CONDUITS MEET CURRENT STANDARDS AND CODES.JOHNSON CONTROLS MAKES NO STATEMENTS WRITTEN OR VERBAL AS TO THE CONDITION OF EXISTING CONDUITS. a) N in w U - Q IMPORTANT NOTICE TO USER:This information may not be sold or transferred to any third party,used on other projects or additions to the project for which it FA-001 ✓ was prepared,or used for completion of this project by any third party. Johnson Controls disclaims all liability for the use or reuse of altered files by the user or x any third party and such use will be a user's sole risk. User shall,to the fullest extent permitted by law,defend,indemnify,and hold Johnson Controls harmless M from any and all claims for loss,damage or injury arising directly or indirectly from any such unauthorized use. - - ©Johnson Controls 2020.All rights reserved.Reuse,copying,modification or alteration of the drawings and other information contained herein is strictly prohibited. GENERAL NOTES: ti 1. ALL CEILINGS ARE ASSUMED TO BE 10'A.F F..SMOOTH CONSTRUCTION UNLESS NOTED OTHERWISE. a, t - 2. EXISTING DEVICES SHOWN SHADED, NEW AND RELOCATED DEVICES SHOWN BALD. Aliilkror4 o - KEYNOTES: � co L0 3 1 'T 6 J �V 10 c I I) 14 1O MODIFY EXISTING NOTIFICATION CIRCUIT N10 AND RELOCATE EXISTING in Lo -____../-____../ i �` NOTIFICATION DEVICES AS SHOWN ON FLOOR PLAN. MAINTAIN SUPERVISION. J_ w 1 rt O EXISTING NOTIFICATION DEVICE TO BE REMOVED AND RELOCATED AS SHOWN. CO ¢�'� i i / // i / / i I RECONNECT TO THE EXISTING"N10" NAC CIRCUIT. MAINTAIN SUPERVISION. 0 / /// • 1- up ,irr _ di , _ AREA c.,o ��.. _ ,ni.� � 'i- /� r�r�rrrwiw.w�r - _ !�J �.� �����s •��r����� �� s 6~i 0 EA OF WORK Fr -W- f'� _ rilfilfilfl- �r�r �� oppr _ i : »���i 11 ■�� it i _. y O o 0 0 ��1� '�'-""" OFFICE 10 '10- di t 304 SC U � wo1 CONFERI=NCE e pw i A06:10.0voor 1, N10-9 303 CPT-1 DECK O *- 2 / r , , 15��� C I CPT-1 j P 1 I B 1NAC3.3RD FLOOR WEST ELECTRICAL ROOM 4009 NACcn A, - ..441I I P-1 B-1 j' 1-�-- r Standby Total Alarm Total co c=,N9, lir30 �'� -"�'-- �E { T. BREAK Qty Description Standby �n� 40 / .�. 1, I _� .r I I Module Y P Current Y Current Alarm ////t Iralli I ► - �� ' .'! "lig I V / ° !I [ i 305,! LVP-1P/ / PAh‘Air - no . anel Equipment I i OR P1 B1�: V X 4009-920 14009 IDNET NAC EXTENDER, 120 VAC 0.0850 0.0850 0.1850 0.1850 ro.,000. l<>" ' N1t7 12 Panel Totals 0.0850 0.1850 SEAN MALLON . 0T..........��" �,....., �. �� _:�. r��. is ra {%Ili) N10 $ �" N103-01 1 15 �' �• _so r ` ,1_64 I ree 15 l / 0 (RL) Notification Appliances Setting LICENSE #5189LEA 1 'n� � b 15 ( oRECEPTION RL _ Irl DN. f _!_, /� V C R {�) C V 1 4906-9104 14 VIO MC NON-ADDRESS,WHT,CEILING 15 0.0000 0.0000 0.0750 1.0500 EXPIRES 10/01/2020 Ii 1►.�i1M��11 _- 0 �° 410r.‘ 301 1.4/ 0 _��r-f �1� ,lir ii CPT-1 30 C 4906-9104 2 V/O MC NON ADDRESS,WHT, CEILING 30 0.0000 0.0000 0.1250 0.2500 pr:fr • O OFFICE 4906-9104 2 WO MC NON-ADDRESS, WHT", CEILING 75 0.0000 0.0000 0.2330 0.4660 j----\ . . 1. 306 I 01,1 if r �.. 01. 1 i AN MC NON-ADDRESS WHT CEILINGI �r diA, � ' ONFERENCE WORK . I 49069130 1 110 0.0000 0.0000 0.3200 0.3200 Av. ._... ,� .. ,' 302 37 F ; I CPT 1 63 . Al ,P-1 B-1 4906-9130 3 AN MC NON ADDRESS, WHT, CEILING 15 0.0000 0.0000 0.0850 0.2580 � `� CPT-1 N9 1.40 • ' 7, , �,`�� , VAr .N157 B 1 t B -�[ 4906 9130 3 AN MC NON ADDRESS,WHT, CEILING 30 0.0000 0.0000 0.1320 0.3960 II ' � 11 65 �� f #A1 $g • C _ V ^�� C 4906-9130 3 AN MC NON-ADDRESS,WHT, CEILING 75 0.0000 0.0000 0.2500 0.7500 ., it A I ..t _ ,.. �. 11 �� i O Peripheral Totals 0.0000 3.4900 �. ���� �`' ;' - - L Added Current for EPS Conversion of 24 to 29 Volt IDNac Devices 0.0000 OA000 (-1:4- ' 1�11�/fir � frir-r J � wN9- 6 ' II irsr � r / V /� PHONERUI Totals00.00000.0000 II ,1,'1 , N10-14 N10-1 1 F �f �!___ 15 15 308 Address Totals Addresses 0.0000 DA000 I�I11 ' / -,� ,� 1*, C" C CPT-1 System Totals : Standby 0.0850 Alarm 3.fi750 N � - , ,., �Iv. � (RU P-1 B-1 7. , Adh �r. `_�ra� , ,moi 1114A���-- _ , �_II - � -I � I7LiI , �` PHONE I . V i i A A i •• i 309 StandbyStandby Y Alarm Alarm v. I Id_ Al • � EO CPT-1 Battery Set#1 (CabinetJCharger#1) Current Total Current Total N. 8 Av. �-13 / P-11 B-1 I Select ALL Power Supplies on this battery set: 0 � ' I AO' O - 75(RL) aer N9- C Ir 1 i 4-- �v. __.,., r.,..---_r, - _r, / i / N10-15 4009 0.0850 3.6750 AZ __ 1 Oi.q �� EOLR Sub Total 0.0850 3.6750 111 - �1 l , i OPEN OFFI E G \` RL)III 310 O 111 - f� PCPT_1 Total 0.0850 3.6750 f [�, � P-1 B-11 kStandb Time= - Standb Ah L_ � � Y 24 Hrsx 0.0850 -2.0400 Yrj � 10Alarm Time= 5 Min0.08333 x 3.675 =0.3063 Alarm Ah I 2.3463 A091 Additional Spare Battery Capacity- 0/° 0.0000 °111 j1 1114�. Arni,illAdli �� Ad , , ,rt • 2.3463 IW �� �.wa•� i�ra� � �u�wi1ierrrrrr► - �� � - Battery Discharge Factor= +i .._� � -wri _�rr.,..rrrr ...a..r,.. sir -,,,..14..""r.._._.wF-...��. ,,s �.� ..,..w� . -.7 �.�. ...�,�s �� r��' o 2 20°/ 0 4693 W,� a 3 Battery o I Required 2081-9272 6.2AFf(2x) 2.8155 € Battery Supplied 2081-9272 6.2AH(2x) a. I *System Totals represent total system current requirements.Those currents may be distributed between multiple battery sets or power supplies as shown above. i . 5 N Class B VOLTAGE DROP SUMMARY Spare cc o �1 Plan Circuit CO DEVICE PLACEMENT PLAN - 3RD FLOOR Circuit Description Load %Drop Capacity o N `� N9 3RD FLOOR WEST NOTIFICATION S1G9 1.770.4 14.11°� SCALE: 1/8" = 11-0° Of) �jN10 3RD FLOOR WEST NOTIFICATION SIG10 1.720A 12.31% 14.00% SCALE:1/8"=1'-0" IN FEET _� N11 SPARE SIG11 0.000A 0.00% 100.00% W 0 4' 8' 16' N12 SPARE SIG12 0.000A 0.00% 100.00% 3.490A Total J N10 Distributed Load Voltage Drop CO cuc o Allowable°/°Drop: _17.9% Wire Res.Per Ft. 0.003070 @ 75°Celsius J Wire Gauge: 14ga Min.Device Voltage: 16.vdc Z it Starting Voltage: 19.5vdc %Voltage Drop 12.31% o a oCkt Capacity 2.A Normal Operation Cl cb Distance Device Voltage Voltage At Device# PID Setting (Feet) Current Drop Device Q N10-1 4906-9104 15cd 30 0.075 0.317 9,18 OCe N10-2 4906-9130 110cd 35 0.320 0.670 18.83 M = LL, N10-3 4906-9130 30cd 40 0.132 0.996 18.50 W CO M r) N10-4 4906-9130 15cd 30 0.086 1.216 18.28 a AREA OF WORK N10-5 4906-9104 15cd 25 0.075 1.385 18.11 Z = W "N. N10-6 4906-9104 15cd 25 0.075 1.544 17.96 G? 7 r:,./., 7 4906-9104 15.',-? 35 0,075 1.750 17 75 Ce " NAC3 PANEL N10-8 4906-9104 15cd 20 0.075 1.858 17.64 O Q 0 L LOCATION f N10 9 4906 9104 15cd 25 0.075 1.982 17.52 N10-10 4906-9130 30cd 30 0.132 2.117 17.38 V OCt N10 11 4906 9104 30cd 15 0.125 2.172 17.33 Z >rts O Q S / N10-12 4906-9104 15cd 15 0.075 2.216 17.28 __ C4, _- N10-13 4906-9104 15cd 45 0.075 2.326 17.17 J !-- I- N10.14 4906-9104 15cd 10 0.075 2.346 17.15 cLi1 N10-15 4906-9130 75cd 35 0.250 2.400 17.10 a, KEY PLAN - 3RD FLOOR Totals: 415 Ft. 1.720A SCALE: N.T.S. L 0 0 v cL DEVICE MOUNTING HEIGHT REFERENCE TrueAlert CONVENTIONAL APPLIANCES TrueAlert CONVENTIONAL APPLIANCES END OF LINE RESISTOR CODES PER NFPA 72 SIMPLEX 4906 SERIES CEILING MOUNTED AUDIBLE I VISUAL SIMPLEX 4906 SERIES CEILING MOUNTED VISUAL z w VISUAL APPLIANCE MOUNTING HEIGHT CONSIDERATIONS IN SLEEPING ROOMS II: o 1. MIN DISTANCE IN SLEEPING ROOMS IS 24"(610mm) FROM CEILING TO TOP AIC SUPPLY ELECTRICAL BOX PROVIDED ADAPTER PLATE FOR !PillNOTE: REFER TO PANEL/MODULE AND DEVICE UOF LENS FOR 110CD STROBES WITHIN 16'OF THE PILLOW OR RETURN THE 4"REQUIREMENT FOR SMOKE DETECTORS HAS BY ELECTRICAL CONTRACTOR. WIRE GUARD INSTALLATION INSTRUCTIONS FOR PROPER m 2. 177CD STROBES, USED IN SLEEPING ROOMS,CAN BE WITHIN THE 24" DIFFUSER BEEN REMOVED FROM THE 2010 EDITION OF NFPA 72 Oto NOTE: DO NOT BRING CONDUIT �, TERMINATIONS. ,,,' (610mm)MINIMUM DISTANCE FROM THE CEILING.THE HIGHER INTENSITY IS o o THROUGH THE REAR OF THE �- , 1 1 REF. BAN)NUMBER ( ) T-BAR WITH CLIPS AND �; F MODEL i2 WATTS CIRCUIT TYPE FIRE ALARM PANEL/MODULE TO COMPENSATE FOR A POSSIBLE SMOKE LAYER. 3' 914mm --t 4 ,NOTE: MEASUREMENTS O ELECTRICAL BOX NUMBER 3 2 3 4 5 (102mm) �:. I FIRE Z MINIMUM CEILING SHOWN ARE TO THE CLOSEST `�� �+ SCREWS SUPPLIED BY I 4081-9001 733-892 2.2K RED RED RED GLD N/A 1/2 ANNUNCIATOR(4300) 4004,4010(TROUBLE) r�iliil�i�irii�.///////v/1/4"/7/1/7//777/7/7/1" ////// i7' //// 777 7r7/-27 /////71////7/7//// ././_ Y ZllT�7IT./I//w/•T//T/✓r�l/JTIW I7TT/.)/////2f)/' 7 1_ " O • \ N.O. I N ITIAT I N G PULL,SMOKE, 4004',4004R,4005',4006,4100, 1lCr///// �`�� ' • � E OF THE DETECTOR. Q� J CONTRACTOR IO ELECTRICAL BOX PROVIDED ` 4081-9002 733 893 3.3K ORG ORG RED GLD N/A 1 HEAT,WATERFLOW,TAMPER, ETC. 4120,4100U,ZAMs a t e.," 24 PT, I/O SWITCH SUPV. 4605 7401,4100 SERIES u) FOR CEILING HEIGHTS LESS THAN 86" NFPA 72 AUDIBLE APPLIANCE 6"MIN CEILING MOUNTED 4" BY ELECTRICAL CONTRACTOR. (2180mm),THE VISUAL LENS MOUNTING (152.4mm MIN) BELOW FINISHED CEILING SMOKE/HEAT . (102mm) I I ♦�O , NOTE DO NOT BRING 4081-9003 733-896 4.7K YEL VT RED GLD NIA 112 CURRENT LIMITED N.O. INIT., 4090 IDNET IAM(EOLR) HEIGHT SHALL BE WITHIN 6"(150mm)OF THE DETECTOR _ �, 012:40 OPTIONAL 4905-9926 NOTIFICATION(DACT) 2080-9024 CONDUIT THROUGH THE REAR CEILING. - O WIRE GUARD WITH 4044,4005,4090 9001 IDNET IAM, = IIIWri. ACCEPTED HERE 12" 305mm �� 11 OF THE ELECTRICAL BOX. NIO INITIATING PULL,SMOKE, J ( ) MOUNTING PLATE 4081-9004 733-886 6.8K BLU GRY RED GLD NIA 112 2190-9173 MAPNETII 2 PT IIC O. OO; O::O HEAT,W.FLOW,TAMPER, ETC ( HEAT DETECTORS III MAXIMUM TO TOP OF SENSOR w 1J e‘b _1.1 V 420MA ZAM(TROUBLE) o F-�R� R P w CURRENT LIMITED N.O. INITIATING c.) AUDIBLENISUAL • AUDIBLE ONLY NEVER HERE + TO NEXT 0*Ia- STROBE 4081-9005 733-984 1.8K BRN GRY RED GLD NIA 1!2 4090-9001 IDNET IAM TO EXIT DOOR / ( ) ( ) MAGNETIC TEST (INLINE) 8,VISUAL ONLY WALL MOUNTED I CIRCUIT •DEVICE OR 10K LOCATION �, �,�, 4 7 N.C. INITIATING(EOLR) 4005*,4090 9001 IDNET IAM F Q APPLIANCES - 5'(MAX) i O (-) {) RESISTOR � 410 410 f II 081 9006 33$9D 560 GRN BLU BRN GLD NIA 1 { ) (1524mm) SMOKE/HEAT DETECTOR � INTENSITY I� INTENSITY DJ1I 4081 9007 733 891 1.2K BRN RED RED GLD NIA 1 N.C. INITIATING(FOLK) 4005 DU o e;; SELECTION PLUG, SELECTION PLUG, - -� =- N 5 TERMINATION VIEW: DEVICE MOUNTING PLATE 4 "T°' ACCESSIBLE ONLY TO NEXT 4081-9008 733-894 10K BRN BLK ORG GLD NIA 112 NOTIFICATION 4004,4005,4006,4008,4009,4010, SYNCHRONIZE MORE �• r ACCESSIBLE ONLY w - THAN TWO APPLIANCES Km FROM REAR OF CLASS B WIRING ; STROBE (+) (+) 4100,4100U ; Q o MAGNETIC 5" t r, FROM REAR OF ••DEVICE OR U, o IN ANY FIELD OF VIEW. a HOUSING HOUSING CIRCUIT (_) {) 10K RESISTOR 4081-9009 733-912 20 RED BLK BLK GLD N/A 1 TO MR 101 RELAY COIL 4005 8 POINT 1/O 96" MAX(NEPA.ADA) DOOR F (127mm) N.C. INIT. (ACROSS CONTACTS) 4005*,4090-9001 IDNET IAM (2440mm MAX) 90"MIN (2286mm MIN)ABOVE FINISHED HOLDER MAGNETIC TEST TERMINATION VIEW SUBMITTAL FLOOR(OTHER MOUNTING HEIGHTS SIDE WALL STROBE INTENSITY STROBE INTENSITY 24 PT. I/O(ACROSS CONTACTS 4605-7401.4100 SERIES ABOVE FINISHED FLOOR LOCATION- WIRING NOTES CLASS B WIRING 4081-9010 733-973 1K BRN BLK RED GLD N/A 1 TO TOP OF LENS SHALL BE PERMITTED BY THE AHJ FINISHED SETTING VIEWABLE SETTING VIEWABLE CURRENT LIMITED N.O. INIT. REF.80"MIN(IBC) © THROUGH THE LENS (IN SERIES WITH CONTACT) DRAWN BY: L.CONEDERA z PROVIDING IT MEETS THE SOUND LEVEL DOOR WALL ■ THROUGH THE LENS 1. MAINTAIN CORRECT POLARITY ON TERMINAL 4090 9001 IDNET IAM {2032mm MIN)REF 96" CONNECTIONS. WIRING NOTES 80" MIN (ADA) OUTPUT REQUIRED.) WIDTH "" '" CHECKED BY: J. HABER MAX(IBC)(2440mm MAX) MOUNTING OPTION A MOUNTING OPTION B 4081-9011 733-974 100 BRN BLK BRN GLD N/A 112 ANNUNCIATOR(N2) 4006,4008,4010 (2032mm MIN) FIRE MANUAL PULL LESS 3" 2. ALWAYS CUT CONDUCTORS AND SECURE UNDER 1. MAINTAIN CORRECT POLARITY ON TERMINAL ISSUE DATE: 1/13/20 ABOVE FINISHED FLOOR 80"MIN(NEPA) PHONE (76mm) TERMINALS NEVER LOOP WIRES UNDER 4081-9012 733-985 22K RED RED ORG GLD N/A 112 SPEAKER CIRCUIT 4003(2032mmMIN) JACK [STATION TERMINALS. 2. ALWAYS CUT CONDUCTORS AND SECURE UNDER 4081-9013 734-086 4.99K YEL WHT WHT BRN BRN 1/2 JOB#: TO BOTTOM OF LENS 3. ANY WIRE SPLICES TO BE MADE BY LISTED AND TERMINALS. NEVER LOOP WIRES UNDER N.C. INITIATING(SECURITY PROJECT#: 448:616912101 ® } * AHJ APPROVED METHODS. 4081 9014 734 092 2.4K RED YEL RED GLD NIA 112 MONITORING EOLR) 4090 9401 IDNET IAM JOHNSON CONTROLS©2020 NOTE REFER TO THE PROPER DEVICE • I TERMINALS. CURRENT LIMITED N.O. INIT. INSTALLATION INSTRUCTIONS 48" MAX(ADA)(1219mm) MOUNTING OPTIONS 3. ANY WIRE SPLICES TO BE MADE BY LISTED AND 4081-9015 734-093 1.5K BRN GRN RED GLD N/A 112 4090-9001 IDNET fAM SYSTEM: AHJ APPROVED METHODS. (SECURITY MONITORING EOLR} FIRE ALARM SYSTEM FOR BACKBOX MOUNTING 48" MAX(NEPA,ADA)(1219mm MAX) I OPTION DESCRIPTION NOTE MOUNTING OPTIONS 4081-9016 734-149 150K BRN GRN YEL GLD N/A 1/2 HEIGHT. 42"MIN(NEPA)(1067mm MIN) OPTION DESCRIPTION NOTE 4081-9017 734-171 3.9K ORG WHT RED GLD N/A 1 MEASUREMENTS SHOWN ARE A 4"(102mm)SQUARE BOX,1 112"(38mm)DEEP. MINIMUM BY OTHERS 4081-9018 734-168 10K BRN BLK ORG GLD NIA 1 701/RMS CONSTANT SUPV. NAC 4100-1260 SHEET TO TOP OF PULL HANDLEA SINGLE GANG BOX,2-114" (57mm) DEEP(MINIMUM) BY OTHERS 378-090 8.2K GRY RED RED GLD N/A 1/2 SECURITY MONITORING(EOLR) 4100,4100U SURFACE MOUNT 4"(102mm)SQUARE 80X, 1-1/2"(38mm) DEEP, 4905-9915(WHITE)OR 4905-9916(RED)ADAPTER 378 046 5.6K GRN BLU RED GLD NIA 112 N.O.SECURITY MON (SERIES) 4100,41000 DEVICE PLACEMENT PLAN FLOOR - B MINIMUM RECOMMENDED,ORDERED SEPARATELY HANDY BOX, 1-1/2"(38mm) DEEP,OR SINGLE GANG BOX 2-1/2" 4905-9910 ADAPTER PLATE REQURED FOR SURFACE MOUNT r /FINISHED Y - B (64mm) DEEP WITH HANDY BOX UNLESS USING 4905-9926 WIRE GUARD 378 069 12K BRN RED ORG GLD N/A 1/2 N.C.SECURITY MON. (SHUNT) 4100,4100U CALCULATIONS AND 1. FOR ADDITIONAL MOUNTING OPTIONS, DOWNLOAD DATA SHEET 4906-0002 FROM HTTP:INVWW.SIMPLEX-FIRE.COM 2. 4905-9928 ADAPTER PLATE REQUIRED WITH OPTIONAL 4905-9927 RED WIRE GUARD 1 FOR ADDITIONAL MOUNTING OPTIONS, DOWNLOAD DATA SHEET 4906-0001 FROM HTTP:IIWWW.SIMPLEX-FIRECOM *USE WITH RETROFIT OR HIGH CURRENT MODULE WIRING TYPICALS a) N_ LU L U_ Q x FA-101 ©Johnson Controls 2020.All rights reserved. Reuse.copying, modification or alteration of the drawings and other information contained herein is strictly prohibited.