Plans (129) F PS2O 19-00062 F'PSaL\Q- OQL \M. 5\..s GIS_CLQAw.1_0i • 4S t- • � � RECEIVED `� �' ° MAY 13 2019 ��111:14W ,D,-, o� �Q� ji' CITY OF TIGARD ko r BUILDING DIVISIONm en CD 0 Lr)Ln Johnson 0)) FIRE ALARM SYSTEM oQ c o 0_� ControlsL..._ � N� . 0 Mco ,...,c.,._, o,ns,,, _ Mc,...... g wor � a �ov DRAWING INDEX LEGENDS APPLICABLE CODES & STANDARDS JOHNSON CONTROLS CONTACTS CI oY� . CI ici till JURISDICTIONS WITHIN THE STATE MAY HAVE AMENDMENTS TO THE STATE ADOPTED CODE.CHECK WITH THE . Sales Representative Drawings Prepared By LOCAL JURISDICTION AUTHORITY FOR MORE DETAILS. FIRE ALARM SYMBOL LEGEND Oregon Structural Specialty Code,2014 Edition BRYAN ADAMS LUCAS CONEDERA BRYAN.ADAMS@JCI.COM LUCAS.CONEDERA EXT@JCI.COM Oregon Fire Code,2014 Edition PHONE:503 683 9000 PHONE:503-683-9000 SYMBOL I DESCRIPTION I BRAND MODELI BOX I WIRE CODE TYPE Oregon Mechanical Specialty Code,2014 Edition Scheduling Drawings Reviewed By PANELS&ANNUNCIATORS FAITH KASKE MARIA GERRONE Oregon Electrical Specialty Code,2017 Edition FAITH.KASKE@JCI.COM MARIA.GERRONE@JCLCOM NAC4 14009 IDNET NAC EXTENDER PANEL,BEIGE,120 VAC I SIMPLEX 4009-9201 IMFG I PHONE 503-683-9000 PHONE:503-683-9000 - sheet List Table National Fire Alarm Code(NFPA 72),2013 Edition NICET LEVEL IV #126987 INITIATING DEVICES Sheet Number Sheet Title F MANUAL PULL STATION SIMPLEX 4099-9001 4G M FA-001 COVER SHEET 1E FA-101 DEVICE PLACEMENT PLAN AND WIRING TYPICALS O ADDRESSABLE PHOTOELECTRIC SMOKE SENSOR WITH SIMPLEX 4098-9714 HEAD 4K M FA-501 PANEL DETAIL AND CALCULATIONS STANDARD BASE 4098-9792 BASE 1C I MODULES&RELAYS I a RELAY IAM I SIMPLEX I 4090-9002 4H M R I NOTIFICATION APPLIANCES OCCUPANCY TYPE(S): SPRINKLER PROTECTION: # STROBE,WALL MOUNT,RED,FIRE,CLEAR LENS SIMPLEX 4906-9101 1A V 4A B Business Group BUILDING IS FULLY SPRINKLED # 4906-9102 1E V STROBE,CEILING MOUNT,RED,FIRE,CLEAR LENS SIMPLEX HB # MULTI-CANDELA HORN/STROBE,WALL MOUNT,RED, 4906-9127 4A V SCOPE OF WORK PROJECT DIRECTORY � � FIRE,CLEAR LENS SIMPLEX 1B # MULTI-CANDELA HORN/STROBE,CEILING MOUNT,RED, SIMPLEX 4906-9128 4A V C FIRE,CLEAR LENS 1B MODIFY DUSTING FIRE ALARM SYSTEM: PROVIDE NEW DEVICES,RELOCATE AND DEMO EXISTING DEVICES AS SHOWN ON DRAWINGS. Site Johnson Controls District-448 MISCELLANEOUS DEVICES ALL NEW WIRING TO BE CLASS B. LINCOLN 3 VSP 545 FNM 10K END-OF-LINE RESISTOR 10K(EOL) I SIMPLEX I 4081-9008 I I 10210 SWR 97223URG RD 6305 SW ROSEWOOD ST,SUITE A LAKETHE EXISTING FIRE ALARM SYSTEM SHALL NOT BE DISCONNECTED OR TAKEN OUT OF SERVICE WITHOUT WRITTEN PERMISSION FROM THE OWNER. IT IS THE TIGARD,OR PHONE: ,O 97035 503-683-9000 BACKBOX CODES CONTRACTOR'S RESPONSIBILITY TO COORDINATE WITH THE OWNER THE TIMING OF ANY EXISTING FIRE ALARM SYSTEM DEMOLITION WORK. FAX: 503-675-6521 CODE BOX SPECIFICATIONS CODE BOX SPECIFICATIONS SERVICE:503-683-9001 4A 4"SQ.BOX 11/2"DEEP 1E SINGLE GANG BOX 21/2"DEEP 4B 4"SQ.BOX 1 1/2"DEEP W/COVER 1F SINGLE GANG BOX 2 1/2"DEEP W/COVER Installer 4C 4"SQ.BOX 1 1/2"DEEP W/11/2"EXT.RING 1G SINGLE GANG BOX 2 3/4"DEEP 4D 4"SQ.BOX 21/8"DEEP 1H SINGLE GANG BOX 31/2"DEEP DESIGN STATEMENT INC 170 4E 4"SQ.BOX 21/8"DEEP W/COVER 2A DOUBLE GANG BOX 2"DEEP 1709 SE 3RD AVENUE PORTLAND,OR 97214 4F 4"SQ.BOX 21/8"DEEP W/11/2"EXT.RING 28 TWO GANG BOX 21/2"DEEP DESIGN IS FOR NOTIFICATION OF THE OUTLINED AREA OF WORK. 4G 4"SQ.BOX 2 1/8"DEEP W/SINGLE GANG COVER 2C TWO GANG BOX 2 3/4"DEEP 4H 4"SQ.BOX 21/8"DEEP W/TWO GANG COVER 5A 5 GANG BOX 21/2"DEEP 4J 4"SQ.BOX 2 1/2"DEEP 6A 6 SINGLE GANG BOXES 31/2"DEEP 4K 4"OCT.BOX 11/2"DEEP 6B 6 GANG BOX 4L 4"OCT.BOX 11/2"DEEP W/11/2"EXT.RING 6C 6 GANG BOX 2 1/2"DEEP 4M 4 11/16"SQ.BOX 2 1/8"DEEP 6D 6 GANG BOX 31/2"DEEP 4N 4 11/16"SQ.BOX 11/2"DEEP W/11/2"EXT.RING FBO FURNISHED BY OTHERS 4P 4 11/16"SQ.BOX 21/8"DEEP W/11/2"EXT.RING MFG SUPPLIED BY MANUFACTURER 4Q 4"SQ.BOX 11/2"DEEP W/4098-9832 ADAPTER MDW MOUNTS TO DUCTWORK 4R 4"SQ.BOX 11/2"DEEP W/RACO 787 OR EQUIV. MBD MOUNTS IN BOX BEHIND DETECTOR 45 4"SQ.BOX 11/2"DEEP W/4098-9863 ADAPTER WM WALL MOUNT ABBREVIATIONS LEGEND DEVICE TAG LEGEND 1A SINGLE GANG BOX 11/2"DEEP DT DESK TOP MOUNT 1B SINGLE GANG BOX 2"DEEP DS REFER TO PRODUCT DATASHEET 1C SINGLE GANG BOX 21/8"DEEP NR NO BACKBOX REQUIRED AC = ABOVE CEILING NEC = NATIONAL ELECTRIC CODE LLiD SINGLE GANG BOX 21/8"DEEP W/COVER TRM 3.5"WIDE SNAP TRACK W/MOUNTING SCREWS AFF = ABOVE FINISHED FLOOR NFPA = NATIONAL FIRE PROTECTION ASSOCIATION PANEL DESIGNATOR AHJ = AUTHORITY HAVING JURISDICTION NIC =NOT IN CONTRACT • FA:=FACP(NON-NETWORK) FOR ADDITIONAL BACK BOX OPTIONS,REFER TO THE XX-700 SERIES DRAWINGS OR PRODUCT DATA SHEETS AND ALM = ALARM NPU = NETWORK PROCESSING UNIT • #:=NODE NUMBER M I INSTALLATION INSTRUCTIONS. ANN = ANNUNCIATOR NTS = NOT TO SCALE • T#:=TRANSPONDER NUMBER a NOTE:EXISTING DEVICES SHOWN SHADED FOR REFERENCE BMS = BUILDING MANAGEMENT SYSTEM PAP = PRE ACTION PANEL • #:T#=NODE:TRANSPONDER NUMBER C = CEILING MOUNTED RC = DUSTING TO REMOVE AND COVER • N#:=NAC EXTENDER NUMBER CD = CANDELA RATING RD = EXISTING DEVICE TO BE RELOCATED • DET =DETECTOR RL = RELOCATED DEVICE CIRCUIT DESIGNATOR DGP =DATA GATHERING PANEL RR = REMOVE EXISTING&REPLACE WITH NEW • A#:#=EPS1 NUMBERIDNAC2 CHANNEL NUMBER E =EXISTING TO REMAIN SCC = STATUS COMMAND CENTER • D#=DOOR HOLDER CIRCUIT NUMBER EOL =END OF LINE SLC = SIGNALING LINE CIRCUIT • F#=FIRE PHONE CIRCUIT M EPO =EMERGENCY POWER OFF SMK = SMOKE • H#=AUDIBLE(HORN)CIRCUIT NUMBER LA FAA =FIRE ALARM ANNUNCIATOR SUPV = SUPERVISORY • M#=IDNET LOOP NUMBER FACP =FIRE ALARM CONTROL PANEL TAC = TRUEALERT ADDRESSABLE CONTROLLER • P#-POWER CIRCUIT NUMBER FATC = FIRE ALARM TERMINAL CABINET TRBL = TROUBLE • S#=SPEAKER CIRCUIT NUMBER LA fB0 = FURNISHED BY OTHERS TS = TAMPER SWITCH FCC = FIRE COMMAND CENTER TYP =TYPICAL • V#=VISUAL CIRCUIT NUMBER CL 0 • Z#=ZONE NUMBER FSD = FIRE SMOKE DAMPER UON = UNLESS OTHERWISE NOTED /� cc FTR = FIRE ALARM TRANSPONDER VCC = VOICE COMMAND CENTER DEVICE NUMBER V l HT = HEIGHT HTUMIDITY VT = VALVE TAMPER BRANCH/ISOLATED LOOP DESIGNATOR (L#)=IDNET ISOLATED LOOP NUMBER 4 HVAC = HEATING VENTILATION&AIR CONDITIONING W/ = WITH • (#)=IDNAC BRANCH NUMBER e1 IMS = INFORMATION MANAGEMENT SYSTEM W/O = WITHOUT •cr CO en• ACCEPTABLE CABLETYPES r�r� r-''Th 1.EPS(E ENHANCED POWER SUPPLY H NUMBER L11 Z CV N 2 FIRE ALARM WIRE LISTMAX = MAXIMUM WF = WATERFLOW 0o MIN = MINIMUM WG = WIRE GUARD 1:T2:A2:1-:.(E1:1) 2.IDNAC=ADDRESSABLE NOTIFICATION CIRCUIT Z W N/A =NOT APPLICABLE WP = WEATHERPROOF Obi I CIRCUIT DESCRIPTION CONSTRUCTION GAUGE CIRCUIT PROPERTIES d d = 15 .: NAC = NOTIFICATION APPLIANCE CIRCUIT XP = EXPLOSION PROOF 3.EPR=ENHANCED POWER REPEATERINI LL c �+ IVDU = NETWORK DISPLAY UNIT 0 OA o TV I VISUAL SIGNAL 2 COND.SOLID 14 AWG X X X SYSTEM SEQUENCE OF OPERATIONS v I CONDUIT SIZE MAX CONDUCTOR AREA CONDUIT SIZE MAX CONDUCTOR AREA NOTES J 0 1/2" 0.12 SQ INCH* 1-1/4" 0.60 SQ INCH* *40%FILL PER N.E.C. Z o r�-1 Q 3/4" 0.21 SQ INCH* 1-1/2" 0.82 SQ INCH* SUBSCRIPT"u":UNSHIELDED CABLES MIXED WITH •• Z N w a 1" 0.34 SQ INCH* 2" 1.34 SQ INCH* SHIELDED CABLES OF SAME CIRCUIT DESIGNATION. �, I ... 1 o **OUTDOOR AERIAL CABLE REQUIRES MESSENGER STP=SHIELDED TWISTED PAIR,UTP=UNSHIELDED TWISTED PAIR ITEMS SUCH AS CAPACITANCE BETWEEN CONDUCTORS AND WIRE GAUGE CAN BE CRUCIAL TO THE CIRCUIT DESIGN OF THIS SYSTEM o ± INSTALLATION.THE INSTALLING CONTRACTOR IS RESPONSIBLE FOR SELECTING AND INSTALLING CABLE MANUFACTURER AND MODEL • THAT MEETS OR EXCEEDS THE ABOVE REQUIREMENTS.RECOMMENDED CABLE MANUFACTURERS AND MODEL NUMBERS ARE AVAILABLE CONTROL UNIT ANNUNCIATION NOTIFICATION REQUIRED FIRE SAFETY CONTROL I SUPPLEMENTARY UPON REQUEST. CP O� \N- �O c, 5 0 O V V O O 5 ' \ P 6 4. 4 O O \. 5 4 AD ��5 \F, F, C,Q' G G� 4) �v \, F% OO �OGPP �‹c �� 0 43-Q<��O�10 OJO,`c�,\O�.�P�P s P'�- C �C�P sZ\ & ���' o Q P �, `� .\ �P �0z, .., , c, <„ VQ- O P �\' c, ��\0�c O�0\<, O�\0\<5, .R� FJO �\��0 ��� �4 Q�<2 .q>.'O� � P k���OcSR- 0' O$.X00 O4 J.0O44 JO O44 JO Q �, . * J P G � C F ZP O G Q G Q �, Q Q Q� P� P 5 < <1` 5� <c. O �, 5o Z �lEll ��I�J�J�J�J�`F,J�J� Q -\� � ����c�<c G��c4 �0 �P `O� CD �- `P,`P,`P ,`P,`P,`P,`P ,`P,`P `� S \O S ,`F� �P 4Q o PG PC' N.C.' PG N.C.' NC) PG PG PG .e) •\�,`s �Q3 c' J� �O 0 Q, <;' kP OP } SYSTEM INPUTS A B C D E F G H I J K L M N O P Q R S T U V W X Y Z AA AB AC AD AE AF AG AH REMARKS GENERAL NOTES RISER DIAGRAM 1 SMOKE SENSOR/DETECTOR • • • • • • • • • • • 1 2 MANUAL PULL STATION • • • • • • • • 2 1. THESE DRAWINGS DEPICT GENERAL LOCATIONS OF LIFE SAFETY EQUIPMENT&FIELD DEVICES.EXACT ROUTING OF CONDUITS IS TO BE DETERMINED IN 3 DUCT SENSOR/DETECTOR • • • • • • • • • 3 s RISER NOTES: THE FIELD BY THE INSTALLING CONTRACTOR TO SUIT CONDITIONS. ALL CHANGES SHALL BE CLEARLY INDICATED ON THE RECORD DRAWINGS. 4 MAIN FLR. ELEV. LOBBY SMOKE DETECTOR • • • • • • • • • • a • • 4 z 2. SHOULD ANY CONDITIONS EXIST THAT DIFFER FROM WHAT IS INDICATED ON THESE DRAWINGS WHICH CAUSE MAJOR DEVIATIONS IN THE WORK 5 ELEVATOR LOBBY SMOKE DETECTORS (EXC. MAIN FLR.) • • • • • • • • • • • • • 5 a 1. RISER IS A DIAGRAMMATICAL REPRESENTATION OF THE SYSTEM SHOWN,THE CONTRACTOR SHALL CONTACT JOHNSON CONTROLS IN A TIMELY MANNER SO AS NOT TO IMPAIR THE CONSTRUCTION SCHEDULE. 6 ELEVATOR MECH. ROOM SMOKE DETECTOR • • • • • • • • • • • 6 ARCHITECTURE IN BUILDING CROSS SECTION.IT IS NOT INTENDED TO o2 3. CONTRACTOR IS RESPONSIBLE FOR MAKING AND OBTAINING APPROVAL FOR ALL NECESSARY ADJUSTMENTS IN CIRCUITING AS REQUIRED TO 7 WATERFLOW SWITCH • • • • • • • • • • • 7 REPRESENT ACTUAL WIRE RUNS,PANEL CONFIGURATIONS OR 0 ACCOMMODATE THE RELOCATION OF EQUIPMENT AND/OR DEVICES WHICH ARE AFFECTED BY ANY AUTHORIZED CHANGE.ALL CHANGES SHALL BE PENETRATIONS.REFER TO FLOOR PLANS AND PANEL DETAILS FOR 8 TAMPER SWITCH • • • • • 8 CLEARLY INDICATED ON THE RECORD DRAWINGS. CIRCUIT ROUTING AND CONFIGURATION INFORMATION. 9 POST INDICATOR VALVE SWITCH • • • • • 9 ,e 4. A STAMPED SET OF APPROVED FIRE ALARM DRAWINGS SHALL BEAT THE JOB SITE AND SHALL BE USED FOR INSTALLATION. 2. ALL WIRING SHALL COMPLY WITH APPLICABLE ELECTRICAL CODES. 10 FIRE ALARM AC POWER FAILURE • • • • • • 10 x 5. THE POWER CIRCUIT TO THE FACP AND TO THE FIRE ALARM POWER SUPPLIES SHALL BE ON A DEDICATED 120V,20A BRANCH CIRCUIT BREAKER,AND REFER TO'APPLICABLE CODES&STANDARDS'ON SHEET FA 001 FOR 11 FIRE ALARM SYSTEM LOW BATTERY • • • • 11 SHALL HAVE A RED MARKING,LOCK-ON PROVISION AND SHALL BE IDENTIFIED AS"FIRE ALARM CIRCUIT CONTROL" THE LOCATION OF THE CIRCUIT SPECIFIC CODE REFERENCES. 12 OPEN CIRCUIT • • • • 12 v DISCONNECT MEANS(CIRCUIT BREAKER)SHALL BE PERMANENTLY IDENTIFIED AT THE FIRE ALARM CONTROL UNIT. 3. DEVICES ARE TYPICAL.SEE FLOOR PLAN FOR QUANTITY&LOCATIONS. 13 GROUND FAULT • • • • 13 6. UPDATE THE AS-BUILT DRAWING SET DAILY WITH JOB PROGRESS. RETURN THE AS-BUILT DRAWING SET TO JOHNSON CONTROLS NO LATER THAN 7 4. EXISTING DEVICES ARE SHOWN SHADED FOR REFERENCE. 14 NOTIFICATION APPLIANCE CIRCUIT - CLASS B/STYLE Y: 14 Z DAYS AFTER FINAL TEST. 15 WIRE-TO-WIRE SHORT • • • a 15 'W- • 7. THE CONTRACTOR WILL MAINTAIN ALL AREAS OF THE BUILDING IN A NEAT AND WORKMANLIKE MANNER. 16 ROOF DRAIN • • • • • 16 c M 8. DO NOT APPLY POWER EXCEPT IN THE PRESENCE OF A FACTORY TRAINED JOHNSON CONTROLS TECHNICAL REPRESENTATIVE. KEYED NOTES: 17 17 O ✓ 9. ANY SMOKE DETECTOR HEAD INSTALLED BEFORE THE BUILDING IS CLEANED AND ACCEPTED SHALL BE COVERED TO PROTECT FROM DUST. ANY FALSE 18 18 °C a, . TIE INTO EXISTING NOTIFICATION CIRCUIT N4:V4.MAINTAIN 19 19 a ALARMS DUE TO DIRT CONTAMINATED HEADS SHALL BE THE RESPONSIBILITY OF THE FIRE ALARM INSTALLER. o • 10. THE FIRE ALARM INSTALLER WILL MAINTAIN THE FIRE RESISTANCE INTEGRITY OF ALL WALL,CEILING,AND ROOF ASSEMBLIES ANY TIME THAT WORK IS SUPERVISION. 20 20 h. NOT ACTIVELY BEING PERFORMED. v� 21 21 O 11. INSTALLATION OF DEVICES SHALL BE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. POWER LIMITED AND NON-POWER LIMITED FIELD (N4:V1) Vl 22 22 I- WIRING MUST BE INSTALLED WITHIN THE FACP ENCLOSURE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND APPLICABLE ELECTRICAL 10K C � 23 23 DRAWN BY: LCONEDERA CODES.REFER TO'APPLICABLE CODES&STANDARDS'FOR SPECIFIC CODE REFERENCES. , V 24 24 I- '' 12. ALL WIRING SHALL BE INSTALLED ACCORDING TO APPLICABLE ELECTRICAL CODES. (N410K 37 V2 NAC4 25 25 CHECKED BY: M.GERRONE 13. FIRE ALARM CIRCUITS SHALL BE IDENTIFIED IN ACCORDANCE WITH APPLICABLE ELECTRICAL CODES. MARK ALL FIRE ALARM WIRES IN ACCORDANCE 4009 26 26 ISSUE DATE: 5/6/19 WITH APPLICABLE ELECTRICAL CODE SECTIONS FOR POWER LIMITED AND NON-POWER LIMITED WIRE. , v 27 27 JOB#: 14 FIRE ALARM CABLE INSTALLED IN DUCTS,PLENUM,AND OTHER SPACES USED FOR ENVIRONMENTAL AIR SHALL BE TYPE FPLP. (N4:V2) 37 V3 28 28 15. FIRE ALARM CABLE INSTALLED IN THE VERTICAL RUNS AND PENETRATING MORE THAN ONE FLOOR OR CABLES INSTALLED IN VERTICAL RUNS IN 10K PHONE CLOSET 29 29 PROJECT#: 448:612405301 SHAFTS SHALL BE TYPE FPLR. V1 30 30 JOHNSON CONTROLS 0 2019 16. FIRE ALARM CABLE INSTALLED IN UNDERGROUND CONDUIT OR OTHER WET LOCATIONS SHALL BE UL LISTED FOR WET LOCATIONS. (N410K) 3 HEKr�� V4 31 31 SYSTEM: 17. FIRE ALARM CIRCUITS EXTENDING BEYOND ONE BUILDING AND RUN OUTDOORS SHALL BE INSTALLED IN ACCORDANCE APPLICABLE ELECTRICAL O A B C D E F G H I J K L M N 0 P Q R S T U V W X Y Z AAABACADAEAFAGAH FIRE ALARM SYSTEM CODES,WHERE APPLICABLE. 18. ALL WIRING,INCLUDING SHIELDS MUST BE DRY AND FREE OF SHORTS AND GROUNDS. 1 20VAC SHEET: T 19. ALL SHIELDED WIRE MUST HAVE SHIELD CONTINUITY AT FULL LENGTH OF THE WIRE. 20. ONLY SYSTEM WIRING CAN BE RUN IN THE SAME CONDUIT. 5TH FLOOR 21. 120VAC IS NOT PERMITTED IN THE SAME CONDUIT WITH LOW VOLTAGE WIRING. 22. MAINTAIN MAXIMUM CONDUIT FILL RATIO AS PER APPLICABLE ELECTRICAL CODES REQUIREMENTS. COVER SHEET 23. EXISTING CONDUITS MAY BE USED BY THE INSTALLATION CONTRACTOR AS DEEMED NECESSARY;HOWEVER,ANY DUSTING CONDUIT WILL BE USED ONLY IF CONDUITS MEET CURRENT STANDARDS AND CODES.JOHNSON CONTROLS MAKES NO STATEMENTS WRITTEN OR VERBAL AS TO THE N CONDITION OF EXISTING CONDUITS. .., L IMPORTANT NOTICE TO USER:This information may not be sold or transferred to any third party,used on other projects or additions to the a project for which it was prepared,or used for completion of this project by any third party. Johnson Controls disclaims all liability for the use or FA-001 • reuse of altered files by the user or any third party and such use will be a user's sole risk. User shall,to the fullest extent permitted by law,defend, X indemnify,and hold Johnson Controls harmless from any and all claims for loss,damage or injury arising directly or indirectly from any such M unauthorized use. _ - 0 Johnson Controls 2019.All rights reserved.Reuse,copying,modification or alteration of the drawings and other information contained herein is strictly prohibited. GENERAL NOTES: .5 1. ALL CEILINGS ARE ASSUMED TO BE 10'A.F.F.,SMOOTH CONSTRUCTION UNLESS NOTED OTHERWISE. _ AREA OF WORK 2. EXISTING DEVICES SHOWN SHADED FOR REFERENCE. ‘Nk.- -11111111.40 0 U 0 M ' b I _ _ i . P 4 i KEYNOTES: • CD 1-n 0 CV 9 N4:V3-7 • 1 DECK OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE N4:V4-2 (N4lOK 1 Ol TIE INTO EXISTING NOTIFICATION CIRCUIT N4:V4.MAINTAIN SUPERVISION. o 0 BREAK V •• �, 507 506 505 504 503 502 15 CONF. N4:V3-6 • `/1 _ •• CPT-1 CPT-1 CPT-1 CPT-1 CPT-1 CPT-1 PA RB-1 P-1 RB-1 PA RBA P-1 RB-1 P-1 RB-1 P-1 RBA • 15 / O CLOSET O 1iH,. 17, .,-t • _ (1 _ , LI \\.. 30 0.1V V 6 • 15 Nom \ ri_ N4:V4 3 TELCO N4:V3 5 V tn cC V V .. O Ocrn • : •'/75 oo �9o 1 F�1 N4:V3-4 I 0 v o tD o II• INTERVIEW V •• °`LA`"• OPEN 1 BULLPEN a �o5 75 OFFICE 30 4 SUITE N4:V3 3 I c �Ner 501 N4:V4-1 I I N4:V4-6 SUITE CPT-1 535 v •• 15 P-1 RBA CONFERENCE 545 V •• RECEPTION • 15 50E I N4:V3-2 N4:V4-47-1) TO NAC4 t'' 30 M1 179 N4:V3-1 V INTERVIEW p� 15 • V 30 -�� NORTH �' ' _ N4:V1-1 .. � 1 N4:V1 2 V V III N4:V4-5 O S FE--- CORRIDOR M1182 S 15 1 11 OFFICE M1-184 15 • OM1183 II 0 C I, J F I V i PHONE CLOSET\ '/ I I510 � III IJII' OM1-180 V 71:L) 43 NAC4 ii M1 181 IIS - Li \ ---_____ _4 1—Ik I II j I . / ^ -1 OFFICE OPEN I I 1 .. V //\ ` ; . '! ; ` ! { I t I. NORRSDOR i! I 1507 I OFFICE L I 1 i �\ I �; I II i i 'I II! �n� ;/ �� TT 1 509 I ,� OFFICE `dl i jI r---1 I i!j �, / N I �. • 511 �= I� J '.\ ;I fi E I 1: MEN i-/ N N4:V1 12 TO NAC4 II 1i I I f / / WOMEN'S RR !. STAIRS 1 ��_ � �i I (N4:V1) • III ii 1 1,L___.!7. RR H # 15_ 5 1� V .. I� ' STAIRS #2 15 11 \ IN4:V1-8 VI 1 % N4:V1-9 IFI _ i(I OFFICE — V - - I / O I I I V • 15 I • 15i I i� !�,j • II N4:Vl 4 M1 185 i i i 0 �' i _ "i • it 1506 I II' ! '" II r N4:V2-1 ;P. I il; , V�� I iii I' I . i �) • HI �I I 75 �, II _ ELEVATOR lli, Ili • 15.,.E I c;✓,� 15. I ;�I 11 I I 11 III LOBBY u I / I i �i N4' 1-7 N4:V1-�0-�i � u: j� III or,N I STORAGE SERVER I ��, I II i<. I I / H�- I - it ,� ., I I' II i !i' 1,1) Iio I)I I J cr-� !I I Ii 1i 512 1513 1 .. V ; III ill , 1 1111 r I' I I - I j4' ! I ��! I .1 1 N4:V1-11 1•• SUITEI V II 15 . • I 15 ! �= I l ui N4:V4 7 I� M1-187 U' i1, T 571 V ENTRY \. 15 • v ill •• 501 :;11 N4:V1-5 S M1 186 75 SOUTH M1-1880 Iii .i ��-- 75 I I '�� N4:V1-6 C CORRIDOR V ,I, Ip i, l Il I — Fri 1 !_ N4:V4 8 i 1 ,/ ' 'y I II y l RECEPTION I \ i ,,I OPEN - 1 „ OFFICE 1 502 I i !I' I I !II III 1505 I 11 (N4:V2) x_15 - I SUITE I II! I 1 lOKAA'" I I u. I V N4:V2-8/`` I V .. I T Ii I 1 N4:V2-2 �\�\ w LI1 IID 1J \ \ 6� ,I Ii I i i°i I I 32 75 , '� ' 7 L'-i7 I �c ii j / a I V -,/ s • IIII I1 BREAK 11 \\ llN; 15 1503 I I(I� � I �� � I�-� N4:V2-5 V Y /' h_11 (N4:V4) F II-T ' ( l I • (.� �= 10K N4:V4-9 T -V i ( ` • I V 3 N4N4-17 ,:`� 15 N,.;i 0 \X, V N4:V2 7 / �. „ 15 I 15 / LL \.• \, • 1 I hy-� 110 N4:V2-6 V N4:V2-3 / . IM- 30 • iz \- . V0. •• N4:V2-4 . iJ 30 30 V 'H �� N4:V4 10 j N �� /. �� ,�A OFFICE Q 4 I 1 504 I /j' .., \ //' M \,,0 1 0 .� 0 0 I . d' v c Cl. ci O c O in A o ob DEVICE PLACEMENT PLAN ! M m M 4 eV SCALE: 1/8" = 1'-0" ,8,.._„ a W w colW SCALE:1/8"=1' 0" IN FEETCe • `m I J � 0 CC 3 0 4' 16' O M 0 g - V Z {./f 0 0 O CC Z kJ 1-1 4CC cIii Z o 0 s Ily 0 J ii DEVICE MOUNTING HEIGHT REFERENCE - TrueAlert CONVENTIONAL APPLIANCES TrueAlert CONVENTIONAL APPLIANCES PER NFPA 72 SIMPLEX 4906 SERIES WALL MOUNTED VISUAL SIMPLEX 4906 SERIES WALL MOUNTED MULTI-CANDELA AUDIBLE/VISUAL lL L_ 3 VISUAL APPLIANCE MOUNTING HEIGHT CONSIDERATIONS IN SLEEPING ROOMS 0 1. MIN DISTANCE IN SLEEPING ROOMS IS 24"(610mm)FROM CEILING TO TOP NC SUPPLY OF LENS FOR 110CD STROBES WITHIN 16'OF THE PILLOW OR RETURN STANDARD ELECTRICAL BOX o THE 4"REQUIREMENT FOR SMOKE DETECTORS HAS ELECTRICAL BOX C STANDARD ELECTRICAL BOX •N 2. 177CD STROBES,USED IN SLEEPING ROOMS,CAN BE WITHIN THE 24" DIFFUSER BEEN REMOVED FROM THE 2010 EDITION OF NFPA 72 ELECTRICAL BOX �. MOUNTING 4"SQUARE 60X 1DEEP o MOUNTING 4"SQUARE BOX, (610mm)MINIMUM DISTANCE FROM THE CEILING.THE HIGHER INTENSITY I \N DEEP J \� 1-1/2"DEEP IS TO COMPENSATE FOR A POSSIBLE SMOKE LAYER 3' H(914mm) 4" NOTE:MEASUREMENTS °� SURFACE MOUNT ADAPTER °I / MINIMUM (102mm) SHOWN ARE TO THE CLOSEST ° SKIRT 15/8"(41mm)DEEP. ;0/ SURFACE MOUNT / CEILING \ / EDGE OF THE DETECTOR 0CONDUIT CUTOUTS ARE 1 , 0 ADAPTER SKIRT 15/8" E 4////////////////////////////////////////,'i///////////,/////////////////////,/i/////////i/��/////////////////,//i i/,///,�////////,/iv'N \\\x : ///////////////////////// //////////// l. / //' ► , I 0 �'�- ►,� } rf; �\�• PROVIDED ON ALL FOUR SIDES. r�� �- °� (41mm)DEEP.CONDUIT �'— NFPA 72 AUDIBLE APPLIANCE 6"MIN CEILING MOUNTEDr�Ii1 0 • .I o CUTOUTS ARE PROVIDED SURFACE MOUNTING FOR CEILING HEIGHTS LESS THAN 86"(2180mm), 4" i , - - SURFACE MOUNTING 4 ON ALL FOUR SIDES. o THE VISUAL LENS MOUNTING HEIGHT SHALL BE (152.4mm MIN)BELOW FINISHED CEILING SMOKE/HEAT (102mm) ►� - CLICK HERE TO /t; b ►� '.', U 12"(MAX) 4 ► (�S i► Z DETECTO \ - / t lb ` WITHIN 6"(150mm)OF THE CEILING. `� ` C CHANGE WIRING FIRING `� M a ACCEPTED HERE �_ (305mm MAX) HEAT DETECTORS j I I ' I_I(+� I_I(+I I ' Q o �� — 1 [FIRE/ NEVER HERE ,1 I CANDELA INTENSITY CANDELA INTENSITY _ 101'11 : ,., FIRE FIRE PLUG ACCESSIBLE FROM PLUG ACCESSIBLE FROM N AUDIBLE ONLY WALL MOUNTED \r/ I•I`.rel • \r/ AUDIBLE/VISUAL �� ;..:� �' `" &VISUAL ONLY SMOKE/HEAT , ` ` `% REAR OF HOUSING -� � ll REAR OF HOUSING ���:�� N TO EXIT DOOR f It ' (' �`'f 1% •;�- i DETECTOR k �� APPLIANCES 90"MIN(2286mm MIN)ABOVE FINISHED 5'(MAX) \ (-) (-) TO NEXT DEVICE \ o FLOOR(OTHER MOUNTING HEIGHTS SHALL (1524mm) `TOP OF LENS: NAC CIRCUIT - - —1 OR EOL `TOP OF LENS: (-) - (_) TO NEXT a 96"(2044mm)A.F.F MAXIMUM (+) (+) RESISTOR NAC CIRCUIT DEVICE OR a • SYNCHRONIZE MORE BE PERMITTED BY THE AH1 PROVIDING IT Q 96"(2044mm)A.F.F MAXIMUM FOR CEILINGS<86"(2180mm)A.F.F.: (+) (+) EOL RESISTOR w THAN TWO APPLIANCES MEETS THE SOUND LEVEL OUTPUT REQUIRED.) <=6"(150mm)FROM CEILING TEP,MINATION VIEW:REAR OF DEVICE FOR CEILINGS<86"(2180mm)A.F.F.: o IN ANY FIELD OF VIEW. MAGNETIC 5" CLASS B WIRING <=6"(150mm)FROM CEILING TERMINATION VIEW:REAR OF DEVICE 96"MAX(NFPA,ADA) DOOR r (127mm) BOTTOM OF LENS: WIRING NOTES FBOTTOM OF LENS: CLASS B WIRING v (2440mm MAX) HOLDER ABOVE FINISHED FLOOR ITY SIDE WALL 80"(2032mm)A.F.F.MINIMUM 80"(2032mm)A.F.F.MINIMUM WIRING NOTES . FINISHED 1. MAINTAIN CORRECT POLARON TERMINAL c REF.80"MIN(IBC) TO TOP OF LENS WALL--..- MOUNTING OPTION "B" CONNECTIONS. MOUNTING OPTION "B" 1. MAINTAIN CORRECT POLARITY ON TERMINAL u L DOOR 2. ALWAYS CUT CONDUCTORS AND SECURE UNDER CONNECTIONS. (2032mm MIN) REF.96" 80"MIN(ADA) 1... WIDTHMAX(IBC)(2440mm MAX) (2032mmMIN) FIRE I-MANUAL PULL LESS 3" TERMINALS.NEVER LOOP WIRES UNDER TERMINALS. 2. ALWAYS CUT CONDUCTORS AND SECURE UNDER Fa ABOVE FINISHED FLOOR 80"MIN(NFPA) / STATION (76mm) 3. ANY WIRE SPLICES TO BE MADE BY LISTED AND AHJ TERMINALS.NEVER LOOP WIRES UNDER TERMINALS. o "' (2032mm MIN PHONE i APPROVED METHODS. 3. ANY WIRE SPLICES TO BE MADE BY LISTED AND AHJ o4 TO BOTTOM OF LENS JACK APPROVED METHODS. o cc °' 0 1111 I MOUNTING OPTIONS MOUNTING OPTIONS N NOTE:REFER TO THE PROPER DEVICE ® 48"MAX(ADA)(1219mm) 1 C INSTALLATION INSTRUCTIONS OPTION' DESCRIPTION NOTE OPTION DESCRIPTION NOTE o FOR BACKBOX MOUNTING HEIGHT. 48"MAX(NFPA ADA)(1219mm MAX) A SINGLE GANG BOX,1-1/2"(64mm)DEEP 42"MIN(NFPA)(1067mm MIN) BY OTHERS.WHEN SURFACE A SINGLE GANG BOX,1-1/2"(64mm)DEEP Z MEASUREMENTS SHOWN ARE B 4"(102mm)SQUARE BOX,1-1/2"(38mm)DEEP,MINIMUM MOUNTING USE 4905-9937(RED)OR B 4"(102m (R m)SQUARE BOX, (38mm)DEEP,MINIMUM OTHERS.WHEN SURFACE MOUNTING USE 4905 9937 4906-9940(WHITE)SKIRT (RED)OR 4906-9940(WHITE)SKIRT DRAWN BY: L.CONEDERA TO TOP OF PULL HANDLE C 2 GANG BOX,1-1/2"(38mm)DEEP C 2 GANG BOX,1-1/2"(38mm)DEEP g FINISHED CHECKED BY: M.GERRONE /FINISHED 7-7/8"H x 5-1/8"W x 2-3/4"D SIMPLEX 2975-9145,7-7/8"H x 5-1/8"W x 2-3/4"D ISSUE DATE: 5/6/19 - - D (127mm x 98mm x 56mm)REQUIRES 4905-9931 PLATE ORDERED SEPARATELY D (127mm x 98mm x 56mm)REQUIRES 4905-9931 PLATE ORDERED SEPARATELY JOB#: 1. FOR ADDITIONAL MOUNTING OPTIONS,DOWNLOAD DATA SHEET 4906-0002 FROM HTTP://WWW.SIMPLEX-RRE.COM 1. FOR ADDITIONAL MOUNTING OPTIONS,DOWNLOAD DATA SHEET 4906-0002 FROM HTTP://WWW.SIMPLEX-FIRE.COM PROJECT#: 448:612405301 JOHNSON CONTROLS 0 2019 SYSTEM: FIRE ALARM SYSTEM SHEET: DEVICE PLACEMENT PLAN - AND WIRING TYPICALS IJ N 0)N W L -' Q x FA-101 M ©Johnson Controls 2019.All rights reserved.Reuse,copying,modification or alteration of the drawings and other information contained herein is strictly prohibited. GENERAL NOTES: 1. EXISTING DEVICES SHOWN SHADED FOR REFERENCE. ..01111111N .:=> . O'•I O A/1 M E/1 (O o 4009 NAC4 - 5TH FLOOR, PHONE CLOSET H Standby Total Alarm Total z Module Qty Description Current Standby Current Alarm O cp P .d� Elm, a Panel Equipment N �„ 4009-9201 1 4009 IDNET NAC EXTENDER,120 VAC I C C o 0.0850 I 0.0850 I 0.1850 0.1850 o o Panel Totals 0.0850 I 0.1850 i U co o Notification Devices N o 4906-9101 17 V/0 M-C NON-ADDRESS,RED,WALL 15 0.0000 0.0000 0.0600 1.0200 0 a dos 4906-9101 2 V/0 M-C NON ADDRESS,RED,WALL 30 0.0000 0.0000 0.0940 0.1880 N o,. 4906-9102 4 V/0 M-C NON-ADDRESS,RED CEIL 15 0.0000 0.0000 0.0750 0.3000 0 o g N 4906-9127 1 A/V M-C NON-ADDRESS,RED,WALL 110 0.0000 0.0000 0.2850 0.2850 4906-9127 4 I A/V M-C NON-ADDRESS,RED,WALL 15 0.0000 0.0000 0.0750 0.3000 4906-9127 4 I A/V M-C NON-ADDRESS,RED,WALL 30 0.0000 I 0.0000 0.1160 0.4640 4906-9127 4 I A/V M-C NON-ADDRESS,RED,WALL 75 0.0000 I 0.0000 0.2210 0.8840 4906-9128 1 I A/V M-C NON-ADDRESS,RED CEIL 15 0.0000 I 0.0000 0.0860 0.0860 4906-9128 1 I A/V M-C NON-ADDRESS,RED CEIL 75 0.0000 I 0.0000 0.2500 0.2500 Perieral Totals I 0.0000 I 1 3.7770 Adlklress Totals 0 Addresses I 0.0000 I I 0.0000 Total Standby I 0.0850 I Total Alarm I 3.9620 Standby Alarm Battery Set#1 (Cabinet/Charger#1) Current Current 0.0850 <--Total--> 3.9620 Standby Time= 24 Hrs 2.0400 Standby Ah Alarm Time= 5 Mins. 0.3302 Alarm Ah Standby+Alarm= 2.3702 . Additional Spare Capacity= 0% + 0.0000 2.3702 . Battery Discharge Factor per NFPA 2010= 20% + 0.4740 Minimum Battery Required 2081-9272 6.2 AH 2.8442 Battery Supplied 2081-9272 6.2 AH IF OPTIONAL SHIELDS ARE USED FOR IDNet WIRING. FOLLOW THESE PRECAUTIONS. 1. IF IDNet WIRING CONTINUES ON TO ANOTHER DEVICE,TAPE M SHIELDS TOGETHER.DO NOT TERMINATE SHIELD AT 4009 FROM PREVIOUS IDNet DEVICES NAC4-VOLTAGE DROP SUMMARY IDNet. / / OR HOST IDNet CONTROL PANEL Plan 2. IF IDNet WIRING TERMINATES AT 4009,TAPE SHIELD.DO NOT M1 Circuit Description Load %Drop TERMINATE SHIELD AT 4009 IDNet. ; TO OR RETURN ADDITI IDNet DEVICES TO HOST IDNet CONTROL PANEL N4:V1 FIFTH FLOOR NOTIFICATION SIG1 1.OI1A 6.51% IDNet CONTROLLER ADDRESS: M1-181 N4:V2 FIFTH FLOOR SUITE 551 NOTIFICATION SIG2 0.915A 5.50% N4:V4 ' N4:V3 FIFTH FLOOR SUITE 535 NOTIFICATION SIG3 0.596A 1.99% N4:V3 V N4:V4 FIFTH FLOOR SUITES 545 AND 571 NOTIFICATION SIG4 1.255A 9.34% N4:V2 : V-0 V--0 N4:V1 . V N4:V1 Distributed Load Voltage Drop T I 133 _•=, ez, . Allowable%Drop: 16% 2x Wire Resistance: 0.0061 ici) - .lei 0 Wire Gauge: 14ga Min.Device Voltage: 16vdc i mm�� 8i StartingVoltage: %Voltage Drop I o 0 9 ' 19vdc 9 P 6.51% q p ., r, q v �I��I© ��IAI- z. �_ +A nun ALM-AIM DA I +AIM-ALM e4e :'7: IDNET MCI NAC2 MCI NAC. '� m ja1 Normal Operation fl ❑ p o Cl Distance Device Voltage Voltage At a 1 �, • Device# PID Candela (feet) Current Drop Device UU El ' u o 1.46.1 LL N4:V1 1 4906-9128 15cd 35 0.08600 0.217 18.78 0 El UR b.: 132 N4:V1-2 4906-9102 15cd 56 0.07500 0.535 18.46 0� Tog N4:V1-3 4906-9102 15cd 20 0.07500 0.640 18.36 .I AUX POWER Q 0 M U o rn N4:V1-4 4906-9127 15cd 31 0.07500 0.787 18.21 ©C [ N4:V1-5 4906-9102 15cd 29 0.07500 0.912 18.09 FosHA RET P4PUT i°Eiz o o s O O U OUT VISIBLEO N4:V1-6 4906-9128 75cd 41 0.25000 1.069 17.93 HARDWIREo o s O O N4:V1-7 4906-9101 15cd 26 0.06000 1.129 17.87Lil RET II �a BATTERY O `'' N4:V1-8 4906-9101 15cd 10 0.06000 1.148 17.85 `J 4009-9201IDNet NAC EXTENDER 8 . 0j c�6 0 0 N4:V1-9 4906-9101 15cd 18 0.06000 1.177 17.82ASSY"ESSABLE Lil ":. 1`BN N4:V1 10 4906 9101 15cd 12 a06000 1.191 17.81 © �V ® /�///////////////////////�/��/ N4:V1 11 4906-9101 15cd 29 0.06000 1.215 17.79 - Y HARNESS733-991 // N4:V1-12 4906-9102 15cd 47 0.07500 1.237 17.76 �__�iNJERNA1BAUERV `n /-� , , HARNESS 733-945 I Totals: 354 Ft 1.O11A ( v �� o �' GROUND 0NEUTRAL ` -CONNECT T0120VAC 60HZ INPUT 3A MAX. am Q c o + + C En _ / HOT 120V ' Ce N T$TRIPERMINAL . PART IFj/ v - N4:V2 Distributed Load Voltage Drop _ 733-991 I 6.2 Ah BATTERY 6.2 Ah BATTERY I 2081-9272 2081-9272 .*, Allowable%Drop: 16% I 2x Wire Resistance: 0.0061 / OA d CO M OM LA Z N N . Wire Gauge: 14ga Min.Device Voltage: W 2 16vdc / Starting Voltage: 19vdc %Voltage Drop 5.50% �'O / VI m /- Normal Operation 0 M O CONNECT A 12 AWG COPPER GROUND WIRE FROM SAFETY - Distance Device Voltage Voltage At GROUND IN THE ELECTRICAL DISTRIBUTION PANEL TO V .Z.1 Q o THE 4009 SAFETY GROUND STUD. 0 X0-1 Device# PID Candela (feet) Current Drop Device N4:V2-1 4906-9101 15cd 54 0.06000 0.303 18.70 Cy o N4:V2-22 4906-9127 75cd 20 0.12100 0.408 18.59 J o N4:V2-3 4906-9101 15cd 20 0.06000 0.486 18.51 1\1/\C 4 N4:V2-4 4906-9117 15cd 87 0.07500 0.793 18.21 0 .. a N4:V2 5 4906 9101 IScd 20 0.06000 0.854 18.15 LOCATION: 5TH FLOOR, PHONE CLOSET N4:V2-6 4906-9101 30cd 20 0.09400 0.908 18.09 NTS N4:V2-7 4906-9127 110cd 60 0.28500 1.035 17.96 3 N4:V2-8 4906-9101 15cd 29 0.06000 1.046 17.95 0 Totals: 310 Ft 0.915A •0 °, cc N4:V3 Distributed Load Voltage Drop - Allowable%Drop: 16% 2x Wire Resistance: 0.0061 Wire Gauge: 14ga Min.Device Voltage: 16vdc J 0 Starting Voltage: l9vdc %Voltage Drop 1.99% w z 0 u Normal Operation cc Distance Device Voltage Voltage At Device# PID Candela (feet) Current Drop Device I- N4:V3-1 4906-9127 15cd 40 0.07500 0.146 18.85 N4:V3-2 4906-9101 15cd 29 0.06000 0.239 18.76 0 N4:V3-3 4906-9101 15cd 11 0.06000 0.270 18.73 a N4:V3-4 4906-9127 75cd 25 0.22100 0.332 18.67 v In N4:V3-5 4906-9101 15cd 25 0.06000 0.359 18.64 0 N4:V3-6 4906-9101 15cd 16 0.06000 0.371 18.63 Y N4:V3-7 4906-9101 15cd 19 0.06000 0.378 18.62 v Totals: 165 Ft 0.596A 0 a v W 1 d 0 o N4:V4 Distributed Load Voltage Drop O Y ee °; Allowable%Drop: 16% 2x Wire Resistance: 0.0061 0 Wire Gauge: 14ga Min.Device Voltage: 16vdc Starting Voltage: l9vdc %Voltage Drop 9.34% I 0 L., E- z Normal Operation DRAWN BY: L.CONEDERA Distance Device Voltage Voltage At CHECKED BY: M.GERRONE Device# PID Candela (feet) Current Drop Device ISSUE DATE: 5/6/19 N4:V4-1 4906-9127 30cd 43 0.11600 0.331 18.67 JOB#: PROJECT#: 448:612405301 N4:V4-2 4906-9101 15cd 26 0.06000 0.513 18.49 N4:V4-3 4906-9127 30cd 54 0.11600 0.871 18.13 JOHNSON CONTROLS 2019 N4:V4-4 4906-9127 30cd 55 0.11600 1.196 17.80 SYSTEM: N4:V4-5 4906-9127 30cd 12 0.11600 1.259 17.74 FIRE ALARM SYSTEM N4:V4-6 4906-9127 75cd 30 0.22100 1.393 17.61 N4:V4-7 4906-9101 15cd 76 0.06000 1.631 17.37 SHEET: N4:V4-8 4906-9127 75cd 21 0.22100 1.689 17.31 N4:V4-9 4906-9101 15cd 42 0.06000 1.748 17.25 N4:V4-10 4906-9101 30cd 19 0.09400 1.768 17.23 PANEL DETAIL AND . N4:V4-11 4906-9127 IScd 16 0.07500 1.775 17.22 CALCULATIONS Totals: 394 Ft 1.255A d, N .--, _V Q X FA-501 M 0 Johnson Controls 2019.All rights reserved.Reuse,copying,modification or alteration of the drawings and other information contained herein is strictly prohibited.