Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans (120)
FPS2O19-00018 01.00 O MO O .- 4k h O O � SCOPE OF WORK FIRE ALARM EQUIPMENT SYMBOL LIST > o MODIFY AN EXISTING ADDRESSABLE FIRE ALARM SYSTEM TO RELOCATE/ADD I SYMBOL NEW EXIST RELOC DESCRIPTION PART # ROUGH-IN / NOTE MOUNTING HEIGHT 0 io w II NOTIFICATION DEVICES TO TENANT SPACE. 1I (E) FACP 1 FIRE ALARM CONTROL PANEL (EXISTING) SILENT KNIGHT EXISTING EXISTING 1 ✓" "" "" LLI 5208 E C w SILENT KNIGHT n O P (N) 5217 1 ZONE EXPANDER 5217 MOUNTS IN FACP FEB _ 7 g Y . g (N)NACot) 1 FIRE ALARM REMOTE POWER SUPPLY SILENT KNIGHT SELF-CONTAINED SURFACE MOUNT ALIGN WITH OTHER EQUIPMENT CII'' 5495 16"H X 12.25"W X 3"D pUIL�'+ 1,...,1 :Id GENERAL NOTES (N)QSYSTEM SENSOR 1 PHOTOELECTRIC SMOKE DETECTOR 2W-B 4" OCT OR SINGLE GANG CEILING MOUNT ,�, 1. THE FIRE ALARM SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH NFPA �� "'""+ , 72 AND NFPA 70, ARTICLE 760, POWER LIMITED SYSTEMS. HORN/STROBE - WHITE - NEW80" MIN TO LENS BOTTOM AFF I i,, c 1SYSTEM SENSOR 4" SQUARE, 4" ACK, SINGLE OR 96" MAX TO TOP OF LENS AFF ++`"" ._ 2. FIRE ALARM WIRE INSTALLED IN VERTICAL RUNS AND PENETRATING MORE (N) (NAC AND CANDELA NOTED AT DEVICE) P2WL DOUBLE GANG BACK BOX '���,;;^"�+ Q THAN ONE FLOOR SHALL BE RISER RATED. 6" MIN 10P OF LENS TQ sEILING , OC 3. FIRE ALARM WIRE RUN IN DUCTS OR PLENUMS SHALL BE PLENUM RATED. STROBE - WHITE - EXISTING RELOCATE • 80" MIN O S BOTTOMAF Iw+,. w. / SYSTEM SENSOR 4 SQUARE, 4 OCT, SINGLE OR w 4. ONLY SYSTEM WIRING CAN BE RUN IN THE SAME CONDUIT. (E/R)©° 1 1 (NAC AND CANDELA NOTED AT DEVICE) SW DOUBLE GANG BACK BOX 96" MAX TO TOP OF LENS AFF z.47I. 4 ,,++,`III C[ 5. A SYSTEM GROUND MUST BE PROVIDED FOR EARTH DETECTION AND 6" MIN TOP OF LF�S TO CEILING wl, 8 LIGHTNING PROTECTION DEVICES. STROBE - WHITE - NEW 80" MIN TO LENS BOTTOM AFF co pl''' + lim IIl , 6. DEDICATED BRANCH CIRCUIT(S) AND CONNECTIONS SHALL BE MECHANICALLY N o 2 SYSTEM SENSOR 4" SQUARE, 4" OCT, SINGLE OR ❑ wL.L,,, w ( )© (NAC AND CANDELA NOTED AT DEVICE) SWL DOUBLE GANG BACK BOX 96" MAX TO TOP OF LENS AFF w PROTECTED. 6" MIN TOP OF LENS TO CEILING i la "" 7. CIRCUIT DISCONNECT MEANS SHALL HAVE A RED MARKING, IDENTIFIED AS C CEILING MOUNT HORN/STROBE - WHITE w "I"I "'++II„,,, "FIRE ALARM CIRCUIT". SYSTEM SENSOR 4" SQUARE, 4" OCT, SINGLE OR (E/R) d 2 7 - EXISTING/RELEGATE CEILING MOUNT " 8. AUDIBLE ALARMS SHALL CONFORM TO SECTION 18.4.3 PUBLIC MODE (NAC AND CANDELA NOTED AT DEVICE) PC2W DOUBLE GANG BACK BOX co w,,.l, 4' (NFPA 72). CI_ILING MUUNI SINOUL - WHIIL Z 9. CENTRAL STATION MONITORING SHALL BE DOCUMENTED UPON COMPLETION c 2 4 - EXISTING/RELOCATE SYSTEM SENSOR 4" SQUARE, 4" OCT, SINGLE OR CEILING MOUNT 1 I II OF THE PROJECT IN ACCORDANCE WITH SECTION 26.6.3 (NFPA 72). (E/RC)© (NAC AND CANDELA NOTED AT DEVICE) SCW DOUBLE GANG BACK BOX 10. A RECORD OF COMPLETION SHALL BE PROVIDED TO THE FIELD INSPECTOR ❑ AT THE ACCEPTANCE TEST INSPECTION IN ACCORDANCE WITH N) NEW SECTION 14.6.2.4 (NFPA 72). E) EXISTING R) RELOCATE SYSTEM SENSOR SITE NOTIFICATION WIRING DETAIL /t 0 N WW � I Icow. 6 \ I c GZ I FROM NAC SOURCE OR n II. >> TO NEXT D EVI csi CE ORi i�nllin n� r---1PREVIOUS DEVICE li .. m. I I EOL(4.7K0) NAC IN NAC - OFFICE COPY NAC OUT -----k\ SW REDWOOD LN (TYPICAL 14 2C) (TYPICAL 142C( NAC + NAC + CITY OP TIGARD 1E CTION 26FOR CODI COMPLIANCE Approved: ] c - OTC: [ j 0 Cihk IA____________.,....___ 40., rmit #: r-,, PSr�l� 1�- O Q n 1 O CAUTION: -� I� �� APS:::dress: I�S �+.i •s �G Upr :‹Ar41 DO NOT LOOP WIRE UNDERite #: L. TERMINAL 1. SYSTEM SENSOR BREAK WIRE RUN TO PROVIDE UNIVERSAL MOUNTING PLATE IDate: '�, SUPERVISION OF CONNECTIONS. • I SW,P2W,SCW,PC2W L-SERIES:SWL,P2WL, SCWL,PC2WL U FIRE ALARM OPERATIONAL MATRIX ZONE SCHEDULE NO CHANGES ADDRESS DEVICE LOCATION / AREA Z-1 EXISTING EXISTING Z-2 EXISTING EXISTING Z-3 EXISTING EXISTING Z-4 EXISTING EXISTING Z-5 EXISTING EXISTING Z Z-6 EXISTING EXISTING Z-7 EXISTING EXISTING Z-8 EXISTING EXISTING Z-9 EXISTING EXISTING An�j Ilium Z-10 EXISTING EXISTINGmai 2 ���� O�✓ed Z-11 PHOTO WESTLAKE CONSULTANTS SERVER ROOM �r, l� (; 011 ��� '„IAC. Z-12 SPARE SPARE Uni FIRE ALARM RISER DIAGRAM Z-13 SPARE SPARE CO= LOI- Z-14 SPARE SPARE Z-15 SPARE SPARE Z 1-12 0) Z-16 SPARE SPARE �•;�1L1©IN OF PERMIT Z-17 SPARE SPARE THE ISSUANCE OF 0 cn �^ TYPICAL NAC Z-18 SPARE SPARE EASED ON A PERMIT CO pWESTLAKE CONSULTANTS SERVER 121 14/2C FPLR CONSTRUCTION - • Z-19 SPARE SPARE DOCUMENTS AND OTHER Z-20 SPARE SPARE Y 1 VIII Z _ VIII EOL e7kn DATA SHALL NOT PREVENT LU • THE CODE OFFICIAL FROM a 2 VIII Z EOL e7kn REQUIRING THE CORRECTION Qct 4.7k0 5SILENT 95 KNIGHT . (4 EOL e 3 SPARE OF ERRORS. OSSC 105.4 N < g N Q `''PP 4 SPARE 120VAC DEDICATED BATTERY CALCULATIONS SILENT KNIGHT 5495 CO co o W WI ce PART # DESCRIPTION QTY STANDBY STANDBY TOTAL ALARM ALARM TOTAL n Q Ot!_ (NAC TRIP/SYNC 5495 MAIN CIRCUIT BOARD 1 0.0750 0.0750 0.2050 0.2050 18/2C NAC 1 NAC OUTPUT 1 1 0.0000 0.0000 1.1900 1.1900 r- r- U. (I NAC 2 NAC OUTPUT 2 1 0.0000 0.0000 1.0730 1.0730 REVIEWED/APPROVED: , NAC 3 NAC OUTPUT 3 (SPARE) 1 0.0000 0.0000 0.0000 0.0000 BUILDING ELECTRICAL ROOM NAC 4 NAC OUTPUT 4 (SPARE) 1 0.0000 0.0000 0.0000 0.0000 .. ........._, • .' ..„.....1-.....0 STANDBY TOTAL 0.0750 ALARM TOTAL 2.4680 *CALCULATIONS BASED ON 24 HR STANDBY TIME & 5 MIN ALARM TIME* c�000c�c�0000 I AMPS (A) X TIME (H) - AMP-HRS (AH) 20% DERATE 18/2C R R R R R E R R 1 STANDBY 0.0750 x 24 .. 1.8000 6666136666 I ALARM 2.4680 I X 0.0833 I - 0.2057 - BEN BREIT-4460LEA 1I I TOTAL AH - 2.0057 2.4068 DWG REV. / DATE 1 / 11 b I BATTERIES TO BE INSTALLED: 7.0 AH 0 01/29/19 1 --I-EXISTING 1 02/13/19 SILENT KNIGHT 5208 2 -EXISTING (EXISTING) PLEASE PROVIDE 3 COMPLETED NFPA 72 4 -IXISTINc RECORD OF DRAWN BY: • COMPLETION AT 5217 FGC 11121315161718192021 II I I I I I I I I I NOTIFICATION CIRCUIT SCHEDULE FINAL INSPECTION CHECKED ED B Y: BJB • • WWa WWW VOLTAGE DROP CALCULATIONS FILENAME: fn to co VI in N v1 to V1 CIRCUIT TOTAL WIRE WIRE VOLT VOLT ACCEPTED VOLT FA.dwg CKT # DEVICE LOCATION / AREA g ORIGIN AMPS DIST SIZE DROP AT EOL DROP DROP X Q I N-1 STROBES, HORN/STROBES WESTLAKE CONSULTANT WEST/SOUTH FACP 1.190 570 14 4.16 16.24 YES 20.42% DRAWING#: V I N-2 STROBES, HORN/STROBES WESTLAKE CONSULTANT EAST/NORTH FACP 1.006 500 14 3.09 17.31 YES 15.14X I:--: I N-3 SPARE SPARE FACP 0.000 0 14 0.00 20.40 YES 0.00X FA_1 NOTE: WIRE TO BE FPL, FPLR OR FPLP PER NEC 1 N-4 SPARE SPARE FACP 0.000 0 14 0.00 20.40 YES 0.00X r e- EN)-OF-LINE METHOD OF CALCULATIO 4 co r- ORIGINAL SHEET SIZE:22"x 34" O N co #OF DWGS IN SET: 5 SHEET 1 OF 2 . .n . . trio lkna �6 ix r~ O � / NOT IN SCOPE W W 1 O • OFFICE OFFICE OFFICE i 107 109 H t , , ftle..6 II- �. �-- J I.-I'�..,.-�. Q 1__-I � - , 'kW ql g mII% % v L �. d BUILDING ELEC ROOM � Q E, c 1 D w (E) MP a co I .1 o D U U U (N) 5217 I I E ..1111111 It i , 1 OFFICE QN-2.9 u U ° 105 = C • I I I I (R)ISI C 0 I Nita 0 U OPEN OFFICE U [0 C) 7, D II N Il 106 f N-2.7 15CD C fi OFFICE U U U 0 0 (R) 104 FIELD OFFICE 110 4 L N-15 0 ---- ra ❑❑ w..u, mf6 _ -1 (N) 15CD ;) ._____ - , Cc : ll II • 11 .1\1 ' 1 - 15CD I 41! iJi MENS 115 --] , OFFICE - OFFICE OFFICE OFFICE 14 11 $ 103 {� C F 114 113 112 FFICE 15CD • - 1" 1 ! C� 1 FRS 22 – f E) 1 ® II WAREHOUSE MEDIUM CONFI VIOMENS i Igig ! I 1a3 101 ! i �- 116 7 C 2 C _____. N-1.3 STORAGE 15C° IF.11.: CONF. i 117 - (N) t-i, HALL 1>-- iv. 123 119 II N-2.3 15CD LOBBY/ 15C� I 0 c RECEPTION c j BREAK ROOM R) 100 � (E) 120 ' 1. , , \ f. N-1. N-1.2 C����N-2.2 75G J::::) C 15 30CQ �` li � ��7 II (E)4.,1 75CD°C) _ \ R N I �.__ N J , O. It COPY ROOMEL7i)III (N) c i Sco SERVER i QUIET 124 (R) �`� RESTROOM I ' 1 TF � 12 142 • [--, . �� N-2.1ThLL± C ` r , (R) ir,----) , I CO ,//i , l'" 1 ., 0 0 , (-) OFFICE OFFICE a li , . 135 127 j OFFICE N-1.8 139o o OFFICE 75aD D 125 = W ( , ,N -)) OFFICE OFFICER I , . .., . ' :- .11 i51.- -''''''''' (12 vJ IQ FF! E o 134j1a Ute} 11, cs CO LARGE CO . OFFICE IR 138 • flN9fl140 115CD4 W . 1( C (R)12:1 OFFICE OFFICE N-1.11 1 OPEN OFFICE O n�i Ct iI o ni _ 133 129 CA 75CD 126 a N ////////////////////////., . 1�n ■ I ) cel CO d w N-1.10 W Lo [Y ..� C 15CD Q 1i (R) ,- I— LL Mill 1 11111 DWG REV. / DATE Wil 0 01/29/19 1 02/13/19 OFFICE OFFICE OFFICE 132 131 130 ` , DRAWN BY: n - r FGC 1 i'l— - ---- 7 4 CHECKED BY: BJB FILE NAME, FA.dwg 2 Q PA� TIAL DRAWING#: CNJ 111, ,,11 in Ill11111 FLOO PLA \ 0 4� 8° ,s' FA-2 i f ,_ '11i1I1', 111111'S SCALE: 1/8"=1'-0n im CS) ORIGINAL SHEET SIZE:22"x 34" N #OF DWGS IN SET: tn N SHEET 2 OF 2