Plans (79) E LC2O 18-00310 RECEIVED MAY 9 MB CITY OF TIW\RD BURPING EIIVI3I0ti SHEET INDEX E0 . 10 COVER PAGE OFFICE �,� , E1 . 00 DWELLING UNIT CALCULATIONS Y E2 . 00 BASEMENT E2 . 10 1ST FLOOR E2 . 20 2ND FLOOR E2 . 30 3RD FLOOR E3 . 00 UNIT DETAILS E3 . 10 UNIT DETAILS E3 . 20 UNIT DETAILS E3 . 30 UNIT DETAILS E3 . 40 UNIT DETAILS E3 . 50 UNIT DETAILS E3 . 60 UNIT DETAILS E4 . 00 ONE- LINE DIAGRAM E4 . 10 PANEL SCHEDULES CITY OF TIGARD REVIEWED FOR CODE CQ�1PLIANCE Approved: ILA /'� OTC: [ j Permit#: G�+"(C 2c' ) rr 1c Address: / Suite #: r- 60. r By: c Date: 5/2-47/ - \�-1 SccLC c\c`\ S* . INFORMATION: SHEET TITLE REVISIONS PROJECT SCALE THREE MM/DD/YY REMARKS N/A A 11490 SE Jennifer St PHASE Clackamas OR 97015 Dennis Welch RIVER TERRACE EAST 1 -- --�-- u ELECTRIC � � UNIT BUILDING E COVER PAGE 2 -_/--/-- SHEET CCB # 162368 213 6_/--/_- 3398S PORTLAND, OR 4 __/__/ E 0 . 10 , 5 --/--/-- I Project: River Terrace Condos # Unity 21 ' Date: 15.2.2018 I Unit Type IBR 2BR 3Br Meter Center (MC) Sq Ft 18.393 Sq Ft 626 909 1243 Code Ref Description Nameplate Derate Volt Amps 220.84(G)(1 ) Gen Lighting Square Footage x 3 VA 55.179 100% 55.179 vA Code Ref Description Nameplate Derate VA VA VA 220.84(C)(2) 2 Small Appliance circuits 63.000 100% 61000 vA 220.82(B)(1 ) Gen Lighting Square Footage x 3 VA 100% 1 .878 2.727 3.729 220.84(G)(2) Laundry 31 .500 100% 31 ..500 vA 220.82(13)(2) 2 Small Appliance circuits 3.000 100% 3.000 3.000 3.000 220.84(C)(3)(a) Dishwasher 22.680 100% 22.680 vA 220.8213)(2) Laundry 1 .500 100% 1 .500 1 .500 1 .500 220.84(C)(3)(b) Range 168.000 100% 168.000 vA 220.82(8)(3) Range 8.000 100% 8.000 8.000 8.000 220.84(C)(3)(c) Dryer 105.000 100% 105.000 vA 220_82(B)(3) Microwave 1 .200 100% 1 .200 1200 1 .2DQ 220.84(C)(3)(d) Water Heater 63.000 100°rG 61000 vA 220.82(B)(3) Dryer 5_000 100% 5.000 5.000 5.000 220.84(C)(4) Garbage Disposal 16.800 100% 16.800 vA 220.828}(3) Water Heater 3.000 100% 3.000 3.000 3.000 220.84(C)(4) Microwave 25.200 100% 25.200 vA 220.82(6)(3) Dishwasher 1 .080 100% 1 .080 1 .080 1 _0e0 220.84(C)(5) Electric Heat 81 _000 100% 81 _000 vA 220.82(B)(3) Garbage Disposal 800 100% 800 800 800 Sub-total 631 .359 vA Sub-total 25.458 26.307 27.309 220.84(A) 21 Unit Derate 37% 233.603 vA 220_82(a) 1st 10,000 100% 10.000 10_000 10_000 Remainder 40% 6_183 6.523 6.924 220.12 Common Area Total wfo heat 16.183 16.53 16_924 Garages at 0.25 VA per SF 3..000 SF 750 100% 750 vA Corridors & Stairs at 0.5 VA per SF 3.535 SF ' 1 .768 100% 1 .768 vA 7- Air Conditioning 100% 1 .200 2. 00 2.400 Storage space at 0.25 VA per SF 882 SF 221 100% 221 vA 2- Heat Pump 100% - - 3- Thermal Storage 100% - - - Total Retail Load 2.738 vA 4a- Heat Pump Compressor (plus 4b) 100°Jo - - - 21-Unit Load Load 233.603 vA 4b- Supplemental Heating for central heat 65% - - - Grand Total Load 236.341 vA 5- Electric Space Heat c 4 separate controls 65% r 1 .950 2.600 - 6- Electric Space Heat >= 4 separate controls 40% - - 2.000 Calculated Load vA divided by 208V 3-phase 656 Amps 220.82(C) Largest of above six items 1 .950 2.600 2.400 Planned Service Size 800 Amps Grand Total 18.133 19.123 18.324 Calculated Load vA divided by 208V 1-phase {Amps} 87 92 93 Planned Feeder Size (Amps) 100 100 100 PROJECT INFORMATION: SHEET TITLE REVISIONS SCALE THREE � 11490 SE Jennifer St MM/DD/YY REMARKS N/A � � PHASE r � ELECTRIC Clackamas, OR 97015 RIVER TERRACE EAST 12 --i--i-- ' ��� Dennis Welch I �--�-- SHEET CCB # 162368 3398S 21 -UNIT BUILDING F LOAD CALCULATIONS 13 __/__/__ PORTLAND, OR 14 __/__/__ E 1.00 Po 0 0 !` ❑ ❑ ❑ ❑ 0, -F11-- it ..._.... _.. E- 0\0 El r—IMMIMIZIMM IV il=1==11, LE —iiiiiii _PlaliCM.t I ,..0 r; „,, _ J:CL 1 0 _I ... ®x ____) - _J- inl w i L TP : ' I (1:1) GDO GDO I �! GDOGDO GDp! �= if�"� ii' GDb i � uW.(:: 4::/. (1--P O 3: ), C--. .. , ; :). 1 CP O rl el 1 31 T7TP 0 GDO3 :i r GDO GDOiti i II:P (1:1) G G , . EM : \ ,GDO G G GY Go! , i , i r G � G I 1 I r r I l r 1 1 - FW k I � FW SUB = ► \ ri -' r i ti - / 1{- • .\ : ir 1 t . , e \ \ r • - ---1( _ , . t ...i I t _ J ,r--:„ ,i--‘ Pjj V viE� L ° % ° ° ° ° aU ° 0 ° ° °U r r ..), 0B UB UB I .,, . . EM UB UB UB UB B EM B UB B UB UB B u.x 64; _______ _, ��� [fin , . , 1 . . _._... . . #4i I' 4 ., - ... . ...._• , . i----W I 11 ' 'Tt-- 1 114 4 .... m 6 PM AT „,,,k l , 4 ! k l IFL.— lki t ....:k-i- : i 4:TkiF7111 i / i ; E--i • I I 1 i 0 POWER AND LIGHTING - BASEMENT FLOOR Scale: 3/32" = 1' PROJECT INFORMATION: SHEET TITLE REVISIONS SCALE `-` THREE 11490 SE Jennifer St MM/DD/YY REMARKS N/A PHASE DP.- t ELECTRIC Clackamas, OR 97015 RIVER TERRACE EAST 1 --/--/-- _ CCB # 162368 Dennis Welch �, � UNIT BUILDING F POWER AND LIGHTING 2 __/__/__ SHEET 33985 BASEMENT FLOOR 3 --L.-L- -4f PORTLAND, OR 4 __/___/__ E 2.00 5 --/--/-- P_1 119 ------p--41?--4---] FT H ,: i.Y 1 p_ n a j 'mt.] L---- 1—P------5117P--1-1UB e !H ii i O g ) II I-'-'1, -A'lb !� [t 9 R g I :[,1-, . . 1 i 1 :I i . , _.. iii ,.. ..„53, , i, .UBi _ I Li , , (------ , 1 ----, = i 1 ___:- —r--- I ______) ! T ' L. 0 \ [7" 'F.'k'' -) \ 1 (---- T1 _ ..g, : 1 _____ .,,,,___ N 00 7--„, ....... , , 1. K_____ _ t- CU • .•.•• 0 D (II N'''----, K-_ _)-- (:) ------'''' , _ ( .1 il : Eam UB DC) 1 1 IP \ IC) 1 \ I 0 01 ._._. r0.1 I--00) i (----) // E ,I Q 01 \____,J Cal l I I PI = 1 - 1 \,_. u o 1 1 .------. h, , ___--) lax q-P F1"1 �q-P „ , r Q 7927, o uB 181 1 0 . g °uB *UB *UB *UB *UBuBu: 'DU L _ EM ex i IiI i „4.). 1=iy, _:___, 1 ,1,_, [61=_, , : ii . ..i .. ._ 2 �"� i 1_/ - / 0. . .. _ _ C ‘-c), ,--,I Ir [1 ) tillii I - W I F /z 1 U , 0 ,._7_,.„ ,i 1 MI / / -1 IT — / / I / -,,_______ ______, , .. 0# (ic) \ . , DD r=I \______i L boo IL \_,_._ 0 e m .._____, ! 0 0 . ., L._ \._____/ L 1 • rli / , n i \,__, NI .! -------1 1 1_, -b B a _ I 1f ; \ I [1:11 W__... I y 7 1 r ,Ni j_ 1 , ,.,..,_„., i ,_,_____- 17-1 : , 1 - �; 40 U B - - - ---- r lar_i Fi9 -i - - ins ....r_t V, 4 1 _1 Fi 0 E M J Mr- laLc ;-' d 4LI '411” 44......1 I_ 43 4b 1:41 ri-mi 1,0._ a i I-) ALk 41171j- 1 a 1 0 W C[ o CDPOWER AND LIGHTING - iST FLOOR Scale: 3/32"= 1' PROJECT INFORMATION : SHEET TITLE REVISIONS SCALE ` THREE 11490 SE Jennifer St MM/DD/YY REMARKS N/A II amacamas 97015 ELECTRIC Dennis Welch POWER AND LIGHTING2 CCB # 162368 2 1 "UN]T BUILDING ---�--�----- SHEET J 33985 1ST FLOOR 3 --/—/-- PORTLAND, OR 4 __/__/__ E 2 . 10 5 __/__/__ 121 0 c---=, op ,=1 ri oj 1[4, ,- ., I i , ,, - I • k • JL 1 ii � ■, • LL I .E .7---- E______ „ , . ._. ._ ... . i ouB .: !: i .! ...... i _ (----- ,! ------):_=_ , L---- � � I et ____,) , _... i ,i... _.___...... . , ,:. O p 0 \/y^ff ' 1 I _ .___ ___\,___. 7 .?___ ____ __.. . - c ipp �/ iiI ---___- .5 R. . 10 . ' OD :." I. i ..E : '1/ i ill „ 1 j----- 7---- \ _ _ a . . , , // _ ., \ / 1110 % I0 ... 0 MI ram . u, EM .._____.) i Ca I - - . 0 I._' % .. ... q4 � �: � • : . I c-1 0 , 1 'C4 ' 1 PI o ... *UB°UB 'SUB °UB 0UB °UBirk B UBIll: . ..._._.. ........... ... •.. ,,,,0 II�1 � 412.:-111°U \_._..) ! ► rji -- „ „ , i---, pi I ,. :- T---i---1.-.....- , ...., ; 0 7 ED I // --0 la r 1 L'. '7- 1 / 6 ] '81 , _____,. , . , • - (51 ____. : , _ , 1-17171° . II [ ) _ -\\\ \ / . 1 , / \ —, // _Li //,,,,? , , ------- , 1:1(B \ 1 J i* , !, QI 0 \,._,../ O Oi -1 Ill. \i_.,---), 0 ci - - ,L ) ._ ; __-_,)_ir-- ----''' / L r 1 r . • ; _... . : _ , N.,, ,N, 1 , : , . ,,,,__._, 5 .K,."____,_ I-- , ,..] , ,,, . ! . [ , . : . . , , , 1-� : I . ....... L. 0 ata I '� i ,, , r-- --n (---- , :. �` 045.1.1.1. ri Ems. M �' 14).... 0 —I ic------- Lijj.1 ' .I —...P , .4j,_,L....71 - i a la -1 a irtr-ji IH'il"i— E:1i ii: 161 ,u 0 POWER AND LIGHTING - 2ND FLOOR Scale: 3/32" , I' PROJECT INFORMATION : SHEET TITLE REVISIONS SCALE dAi THREE 11490 SE Jennifer St MM/DD/YY REMARKS N/A IP� PHASE Clackamas, OR 97015 RIVER TERRACE EAST x ---�.�-�-- ■ ELECTRICDennis Welch POWER AND LIGHTING CCB # 162368 �I � "UNIT BUILDING I~ �._I__.I_- SHEET k l 3 /--"-- �. 33985 PORTLAND OR 2ND FLOOR 4 -_I-_I_- E 2. 20 5 __/__/__ 1{ 1JJ ° • • i ''''''" -----[_i 4E7 _ 66 Et 1--".! !. i . - ) immisaiii • n - ," -J i ,._ Q� —�. 0 vEMv _,„.P, B - .L___ ?. — \I/ r _ , . ! . ____.is _ i_..1... . =. (---.J 6] -------- _ . _..._. . .. ... . . cm. , . : ,_.. 1 . . ..., . . ...1L._. ... - H--' 1'i - . ',I I. ) ) - LH 11 (------ r_i_io a U- I I I ___- ,}1 ! I I 1 i 7C1' \'--- el I) (Th - (----\ r7,,,.____ -14,..___..\ ..7--)° ij i r---- _it ff100 1 ___,) ! CA . :____LCIG -- ) ! 1 ? &\ rTh—H 1 r*UB . ,. 7 EMjv v.. ................... . ,. _. 1 \,__I', 1 • ! ,,,L , 8 0. „----1 • . . . , � ,,,__L__, 1, .„. ..._.......____....„....„!......, . , . , ............ .._ r---3 _ • 1 I I lo , 0. 1 °X 14) 171"Etk744) r= 1 rcj I ØLI Ai *U°UB JB °UB °UB °UB °UB JB "�1: 0U CD) I 1,,. ___,a 1 EM E .i7 , 11 I MN I grip . 0 L nc) 7 - r_ I� 10 - e I a I . ii EM! 1 1 1 I ' / < .. - .� // e / 0 _ — \ [ I r_n_..\;-.........._]---/ 0 4C113 eD , DO . . ' I ! 1 .--"--) •,._____-/ 1 C) I I ri 1 cl.. . ... .. • _ _ , ... ___: ._ --i'- i , J i 1s J., L n ..„. ..____}I 1 ,------.._. .. q ri.,_ __,___ l'__ 4.11 T K______ i . . .. ,,.,,_..__ 7 , . 1 ,_ a)E AIELIA r---j U :=- 5 tiP • (---- r - ' , 71M1 . Lii S ' — dY � ..=-7---11'-4P---41------ 4 ' 'I • ..,- • CoI 101 °I ° L ` °I ( 101 (------- POWER AND LIGHTING - 3RD FLOOR ,s.,.____} Scale: 3/32" = 1' PROJECT INFORMATION : SHEET TITLE REVISIONS SCALE AAS THREE 11490 SE Jennifer St MM/DD/YY REMARKS N/A pw�- PHASE ELECTRIC Clackamas OR 97015 Dennis Welch RIVER TERRACE EAST POWER AND LIGHTING 1 2 __/__/__ ■ CCB # 162368 21 -UNIT BUILDING I= --/--/-- SHEET Wilr33985 3RD FLOOR S --�/--L_ PORTLAND, OR 4 --/--/-- E 2 .30 1 1 sus —qv P- Y--9:: Q _ ' II I �� x ® l' ' i/ 7-- - , 131:11r " r.% 'III I � r_F�r ♦ I ttl. - -I ' - GF: \ ,4-1,r— ars i ( CF.GI_ ♦ / _. �_ • n ug • 1 F uB , • ;?, uaie). 1 UC . ��..� J S% �#D� UC - ._. ...» � _J i D�. � �4J� U C I � ` � - � J DP•� ` �4J'D T r ` � (__ . ..-Q--„,--L, _ CFC: C - -m G-CI - (th LI DIr -1_41_ ELEC. PAN _ ELEC. PAN IQ _ rE 11) �� ELEC. PANEL ' An 7 ,.. ,.---% , '4' ' 35 aro a:4 III, *AA _ / ♦ SII► 4I / A— ill '1 *4 r Ily 0 •'A). r UC‘" uc uc I il TV I re UCo ‘, 1- ../ U0 \ C ♦ UC \ g TE • c' Ei AC 15 %,... ,...... ,.1 . ..... ••••• . ACAb h `Iw_. � • . .... .... . ill es el t 1r7 43 r ' 'v"' I GFCI GFCI eC GFCI AC 1 I ` WP0 AC `� WP 111 AC `� WP C 1 __—1-n, uP _ --_._.._ _ i `� i.I.. .... UP - -- - I tp_o_______d1 U P "APS a Fp] EL=Ij 01 0 1 A r-' POWER AND LIGHTING - UNIT PLAN 1-3 (--- POWER AND LIGHTING - UNIT PLAN 1-3 - TYPE B POWER AND LIGHTING - UNIT PLAN 1-4 Scale: I/8"=1' �� Scale: 1/8"=1' Scale: 1/8"=Y� .....,_} PROJECT INFORMATION : SHEET TITLE REVISIONS SCALE '-Na. THREE 11490 SE Jennifer St MM/DD/YY REMARKS N/A _1.1P/1"-- PHASE ELECTRIC ,Clackamas OR 97015 RIVER TERRACE EAST 1 _ � _i__ _ _ _ CCB # 162368 Dennis Welch _ _ 21 -UNIT BUILDING F UNIT DETAILS 2 �/ / - 1 SHEET V � 33985 3 _L...../..._ 1. PORTLAND, OR 4 --/--i l E 3 . 00 5 --/__/-- :WI - ,---- I p - - - - ` 4-., . III 1 -41)-- .� - - III y • 11111. I 9 .. . GFCI '1 1 9 0 —0— p,--- - - ..:;n JI 41 / G I n 70, o / 4� F I L F I I I 1 , : 0 / U B de GFCI >11., ----1-)p- 0 :11)1::". , ,utsCv , _i _ ,,-.„.. 4 -b•ffuFdI f.,4 * a/ 1 uC D D • a %,..,q).-7 :1 - cFCI cr� �� c - ' 0 r • itifi4 ~ ---nELEC. PANEL '—. 5 �. . uc Grc.� vFCI C UC . / •••• ". _ — _ 1 i [I_ 4-1_/ 9. 1.r1 414 (14) i . , r 0 , .... 0 1 0 `N. -7 Np - / 11 - 1 _ / . r I • luc 0 -- ----- ° . a"). ! E _ r, if:;c i . ... i 1 3 , �0, ELEC PANEL 1 — / 1 , 0 ‘ 3Q ..-A- .- rgC iv -1--/ / 'I'uc UC n o' I 01/ % . '1 Es , � uC , 1. • uC _ / -... .,.. . ...... ••• a !rv'I AC ......_xi i�k la dt4 - t.L. CI 4 i iv -43 it __,a di G FCI AC t I WPL_Irs ill /-1c0" WP • FEMME, III Ac y ♦ GFCI - UP .. [Eu1 •� ilk II UP Pl POWER AND LIGHTING - UNIT PLAN 1-4 - TYPE B0 POWER AND LIGHTING - UNIT PLAN 2-2 Scale: 1/8"=1' Scale: i/8"=1' PROJECT INFORMATION : SHEET TITLE REVISIONS SCALE fTHREE 11490 SE Jennifer St MM/DD/YY REMARKS N/A Oww- PHASE Clackamas, OR 97015 RIVER TERRACE EAST 1 _—I__I_— v1W�" „� ■ ELECTR[C CCB # 162368 Dennis Welch 21 -UNIT BUILDING F UNIT DETAILS 2 --/--/-- SHEET J 33985 3 _-�--/-_ PORTLAND, OR 4 __/__/�_ E 3 . 10 5 ---I._.-I-- NOTE : 1 . PROVIDE SEPARATE 120V 20-AMP CIRCUIT FOR DISHWASHER ON SINGLE RECEPTACLE. 2. PROVIDE SEPARATE 120V 20-AMP CIRCUIT FOR COMBINATION MICRO/HOOD ON SINGLE RECEPTACLE. 3. ELECTRIC WALL HEATERS TO BE 1000 WATTS. 4. ADD OUTDOOR LIGHT, SWITCH AND RECEPTACLE FOR UNITS WITH PORCH. 5. GENERAL NOTE ALL ROOMS TO HAVE TAMPER RESISTANT RECEPTACLES PER OESC 406. 12. 6. SWITCH FOR DISPOSAL SHALL BE ON BACKSPLASH WALL. 7. ADA ROOMS SHALL HAVE SWITCH FOR HOOD LOCATED IN REACHABLE AREA. -opl . , 60 fi , 1 rfay .., i 7 — r_______. _._. . .. .................,______,...... . .1 AC4 r 1 • I I- � iii ` GF I ' '' :� ` I DO-_-_ fr r } (at'(.. ,N 671I _ ci cI '� it,'"'! ' ,:. 1r iuc c 4 ' Illi �-- n � � U13 - 1 r .0." "4%0 ice;FCI , o J iNr r�iUC - ) . D UDL ` / ali , ` _ III�� ri:::16rES• , , � ' _1 44 Cc i AA- / " ` 31MF 0 9uc • ;�,,'.. ro ril uc1 : 44..,,stQ ,M' Al1 % 0 Fl 0 ,_,2„,, i 0 �O` ' Tu c grr i $$i r /..-- — +A- ah \ , T -0 T1/ I 2l1H qs / ELECINV I / ii... .7 EEC \ \ ♦ / �s PANEL / o PANELilbi • ` ,' `�,� t ,4i . TV / NT, 1--- Go r ‘ N • ..... / r / # 1jc •-••"1- iil' ,.. UC 1 I 0u uc \ uc .... , uc .....-0 uC6 , IN' ISM / ! - - - —<> _ m 1 - PI 1 `� •/ _ GFCI `El i - i= 0 irt- - ‹) \uc 1 i ---41-- AC 1 I 1-P \ —_ L!_* , / — _ 1 _ (FAC WP \` 1. UD Np�UD ._ .. -�k GFCI SO a° 1. , r--6----1 q _ j cX r9 1 _ iq� rET I ` G Cl I LE------, UP . 1 1 , WP ❑ 3 I� V GFCI '/ lae--..__._-. I ._likILYT �I1. V _._ ..f__.r.. .._.._,_.,. ...____..__ 1 1 P T❑1 o 0 POWER AND LIGHTING - UNIT PLAN 2.2 - TYPE B POWER AND LIGHTING - UNIT PLAN 2.3 Scale: 1/8"=.1' Scale: 1/8"=1' PROJECT INFORMATION : SHEET TITLE REVISIONS SCALE dAir -%‘‘THREE 11490 SE Jennifer St MM/DD/YY REMARKS N/A 3 PHASE ELECTRIC Clackamas, OR 97015 RIVER TERRACE EAST 1 ___/__L_Wf t CCB # 162368 Dennis Welch 21 -UNIT BUILDING F UNIT DETAILS 2 I--I-- SHEET 33985 PORTLAND, OR 4 __I_-I-- E 3 . 20 5 __I__I__ NOTE: 1 . PROVIDE SEPARATE 120V 20-AMP CIRCUIT FOR DISHWASHER ON SINGLE RECEPTACLE. 2. PROVIDE SEPARATE 120V 20-AMP CIRCUIT FOR COMBINATION MICRO/HOOD ON SINGLE RECEPTACLE. 3. ELECTRIC WALL HEATERS TO BE 1000 WATTS. 4. ADD OUTDOOR LIGHT, SWITCH AND RECEPTACLE FOR UNITS WITH PORCH. 5. GENERAL NOTE ALL ROOMS TO HAVE TAMPER RESISTANT RECEPTACLES PER OESC 406. 12. 6. SWITCH FOR DISPOSAL SHALL BE ON BACKSPLASH WALL. 7. ADA ROOMS SHALL HAVE SWITCH FOR HOOD LOCATED IN REACHABLE AREA. ;1 1--__---, ..... „cr. uksa q.,p 1 . ." .. r.- ---.--. ---.."-h:;:j vi: ! 0 1 1 �' GrL AC : ---- 11 • 411 ' 1 / GFCI r_�rr IA 4, i---- --- -I �� UB 1 I WP – -i i , Ipi F•: { milli - ell ., r IZ7 - e_e:07.., 0 r� 30 / / UCL I. +11 UD 114° UD 0 I a/174:1118N _ • cam � � � � 1 Tu ♦ ELEC F UC� w �4 Li \ I GFCI -". i / w� , ,�� / `, oi) Fil 0 FI1R UC PANEL -ksel- - - - --' -- I) - ---1 W I I ii, .. . ‘ $$ 4 , 1:111-I "k ••••. GFCI � lilc/ E / i � i ♦ ♦ \ 1. 96 PANEL � � ! -- --- -• /q4:1C D ♦ � � ♦, ��'' _ r ' ♦ � %� __...._. .-1 .6. \\ - 1 ,� D i a _ ♦ / -71-it;)_ - n45:f1 tb -r„ 1 ________b_ ' GFcI i , 1 _ ,. i 0 by_ .D- GFCI / �j r_.: i ....til 1 / U C 1, 3 0 Li' 1 !._tcec . y ,1 43...6:r 1 dt P / 0 \ \ \ ,` ... \ \ am,k— '. -, , \ I '76° ' d $-,____ — . , 0- .. .. . .... ..___........„ 1 : _,..,_ . ., , - -- \- - 0 i ‘,- 1 (1:1) I d 71- Ase -6-, \r (,- -, , r I + � .._ ... . . . . _WPG CIA. UB Ill +1) «m 0 GFSI/ I UP AC o I oi 1 r..... di) j 1 Ilk ei - - ,. - 1 r POWER AND LIGHTING - UNIT PLAN 2.4 POWER AND LIGHTING - UNIT PLAN 2.3 - TYPE B0 Scale: 1/8"..eScale: 1/8"=f PROJECT INFORMATION : SHEET TITLE REVISIONS SCALE Al& THREE 11490 SE Jennifer St MM/DD/YY REMARKS N/A 'w' PHASE Clackamas OR 97015 RIVER TERRACE EAST 1 __/__/__ ga ■ ELECTRIC CCB # 162368 Dennis Welch 2 1 -UNIT BUILDING F UNIT DETAILS 2 ---1----/-- SHEET l 3398S 3 -_������ PORTLAND, OR 14 __/_ /__ E 3 ,30 5 _-/__/__ NOTE : 1 . PROVIDE SEPARATE 120V 20-AMP CIRCUIT FOR DISHWASHER ON SINGLE RECEPTACLE. 2. PROVIDE SEPARATE 120V 20-AMP CIRCUIT FOR COMBINATION MICRO/HOOD ON SINGLE RECEPTACLE. 3. ELECTRIC WALL HEATERS TO BE 1000 WATTS. 4. ADD OUTDOOR LIGHT, SWITCH AND RECEPTACLE FOR UNITS WITH PORCH. 5. GENERAL NOTE ALL ROOMS TO HAVE TAMPER RESISTANT RECEPTACLES PER OESC 406. 12. 6. SWITCH FOR DISPOSAL SHALL BE ON BACKSPLASH WALL. 7. ADA ROOMS SHALL HAVE SWITCH FOR HOOD LOCATED IN REACHABLE AREA. n In // '0; :en_A7_10 0 ?ril - ittp I qm r.71 (;) GFCI _GFC T .arf�FCI - --...f���� 1 WP di : / I / GFCI r-- P---1 — I cp , UD 1 4 . � � I1I `fir, 11, r AC 0 IT\ _ ,-1, , , .9 , . 4io . :___, 1 ELEC N t ---z--.— , " -- - , ,. ( , <:::: : T ' �I uC i • uc 41 39 \ - eC ‘ 1 Ti, ,���♦ t E LEO, , 1 I uc `tic 1 I (�� 01/ D ► ' PANEL . - _, / AC ♦ ' t-. . TM .�. ...-.GFQ I i ill p L ! ' ` .4(\).I , l 1 ,--Aili, 1. 0-- X MR / &Ow , UC A bt$ , LwI TLi ..y. „___PT, \ , ,,__I---Lr ♦ UC -datP- ..� ' a . _ .1 !I .1-4-711' '41 i // 0 \ . --- --- 1 41E344Pr S uc * UD UD ' : $L=I I 1 \ \ (- \y . -=-..::. • , .... ,iiff , , . 0 1 1 Q , 4U 5 , 4C. i .46 '*/ — 2 i \ UC0.... C #113 FCI1 4 . sr •=i, f--� 4C 1 ]• / N ! URA \ / , / Fi ivi GFCI , 478 1 11.11[111 it ill 0, ,,, 0 UB.9. ., , ....... __ . __.. . _ . A I^ �`rr'i I"1l. o 1 ! r -- POWER AND LIGHTING - UNIT PLAN 2.5 POWER AND LIGHTING - UNIT PLAN 2.4 - TYPE B0 1/8'=1' Scale: x/8"—x' PROJECT INFORMATION : SHEET TITLE REVISIONS SCALE THREE j#-A- 11490 SE Jennifer St MM/DD/YY REMARKS N! A PHASE DP ELECTR[C Clackamas, OR 97015 RIVER TERRACE EAST 1 I _I__ _ CCB # 162368 Dennis Welch 2 -UNIT BUILDING F UNIT DETAILS 2 --I--I-- SHEET kikl 3398S PORTLAND, OR 3 �a/--/sg 4 __/-_/__ 1 E 3 ,40 5 __I__I--_ NOTE : 1 . PROVIDE SEPARATE 120V 20-AMP CIRCUIT FOR DISHWASHER ON SINGLE RECEPTACLE. 2. PROVIDE SEPARATE 120V 20-AMP CIRCUIT FOR COMBINATION MICRO/HOOD ON SINGLE RECEPTACLE. 3. ELECTRIC WALL HEATERS TO BE 1000 WATTS. 4. ADD OUTDOOR LIGHT, SWITCH AND RECEPTACLE FOR UNITS WITH PORCH. 5. GENERAL NOTE ALL ROOMS TO HAVE TAMPER RESISTANT RECEPTACLES PER OESC 406. 12. 6. SWITCH FOR DISPOSAL SHALL BE ON BACKSPLASH WALL. 7. ADA ROOMS SHALL HAVE SWITCH FOR HOOD LOCATED IN REACHABLE AREA. U P ILIA ail (rprl,---i(---filiTA----=': AC ,.. t GFCI —' t. 0 �r ♦ E n . I 4.: � WP Q GFCI 7 ti q _._.1, l"f W P A . wy _ . lim 1"f AC _ P - - A = 0 _ x, • ©! iWi: ,� "' ` ill) ! ! / r ♦ ® � C I ,, / - d / , TV - 1 UC / . -N ♦ � i . TV k 30 / uc ♦ _ : 1 \ uca, • /- -- -9- T • I l 1 UC 1 \ \ • \ Ice, 0• ELEC` 1 I \ 31 o I PANEL � „ . 115 I ♦ \ . 0 Q / � . I / C) I i: I . 1 11A1 l' r 7.- ..,k , 7 ill frell .. .... _. .. .ri‘uc 1 0 i 1 . . . .1 / . !. 1,40 • i-, -- , _ \ 1 . ; pLwIJ � it) , ;.ci GFC;i UC j: 3F l 4 4 r\ : NEL rErr 41.11) 4c i • / ..1:32s, _.... ..... 43.11D —; ! UC 4# - ' it, 9 J . •.31 ,L, -1 (--Th \y. lie N 4 . , Q ' '''-- ) • lOB • FCI a / ;4* \ 4 UC /__-- S/ /6 / _ ' 11110 GK. r, \\ \ rF 4iu. -SCI P11 :k rIV' !IrU 4:1 f-71 8 Ai_ ________. . _ . . ,..._ ............ ...,..„__ . ._. _ ..._ .. --�- K--A-1 - �, Ili �_ _ .�„ .......„.•... ...,..11.... ... .. .... LJL.1.11LALMLYI • • . `.! . POWER AND LIGHTING - UNIT PLAN 3.1 POWER AND LIGHTING - UNIT PLAN 2.5 - TYPE B0 scale: 1/8"=1' Scale: 1/8"_f PROJECT INFORMATION : SHEET TITLE REVISIONS SCALE -``THREE 11490 SE Jennifer St MM/DD/YY REMARKS N/A PHASE _�ELECTRIC Clackamas, OR 97015 RIVER TERRACE EAST 1 __�__�__ CCB # 162368 Dennis Welch 21 -UNIT BUILDING F UNIT DETAILS 2 -----I---I__ SHEET 33985 PORTLAND, OR 14 __/__ /__ E 3 .50 NOTE : 1 . PROVIDE SEPARATE 120V 20-AMP CIRCUIT FOR DISHWASHER ON SINGLE RECEPTACLE. 2. PROVIDE SEPARATE 120V 20-AMP CIRCUIT FOR COMBINATION MICRO/HOOD ON SINGLE RECEPTACLE. 3. ELECTRIC WALL HEATERS TO BE 1000 WATTS. 4. ADD OUTDOOR LIGHT, SWITCH AND RECEPTACLE FOR UNITS WITH PORCH. 5. GENERAL NOTE ALL ROOMS TO HAVE TAMPER RESISTANT RECEPTACLES PER OESC 406. 12. 6. SWITCH FOR DISPOSAL SHALL BE ON BACKSPLASH WALL. 7. ADA ROOMS SHALL HAVE SWITCH FOR HOOD LOCATED IN REACHABLE AREA. 4 [ t. [ L -0- `�..... .. GFCI ` 1714. fir' li___Firp WP IF 0 1 a ACV i /i lk rk ill - / ..-- .T..." N 1PTINIMMil I , 1 / �--1 -. � UC AC I C ; TV 1 C , v- . (52) / UC j TV I \ UC /� _. UC • � ♦ CI. � Q. { ♦ • / © 0 i / 1) 41 WI_ �'1. stti GFCI4 ,,..... c FCI r.n.- III — i • .. . / , e• (.. .w. .$ (-------- '---;411%1111 UD UD tic , f . N l uC /Ub•• a �.• UC / UBO 0/c . ID __._,,/ CO U , C�F(a 0 G``CT� t 7-1 M27 ilk 14) ' ', Air , w POWER AND LIGHTING - UNIT PLAN 3-1 TYPE B Scale: 1/8"=1' PROJECT INFORMATION : SHEET TITLE REVISIONS SCALE .-. THREE 11490 SE Jennifer St MM/DD/YY REMARKS - N/A PHASE 1 1211 ELECTRIC Clackamas, OR 97015 RIVER TERRACE EAST 2 .�_/-._I__ CCB # 162368 Dennis Welch 2 1 -UNIT BUILDING F UNIT DETAILS -- --�-- SHEET 3398S PORTLAND, OR 4 __i__/__ E 3 . 60 FEEDER SCHEDULE I 1003 I 3 #2 AL SER, 1 #4 AL GND NOTES: UNIT XX TYP OF 7 1 . TERMINALS AT METER CENTER (MC) AND DWELLING UNIT LOAD CENTERS ARE BOTH RATED AT 75C. THE DWELLING PANEL UNIT FEEDERS HAVE BEEN SIZED PER NEC 110. 14(C)(1 ) AND 310. 15(B)(7). 125A FOURTH LEVEL UNIT XX TYP OF 7 PANEL 125A THIRD LEVEL UNIT XX TYP OF 7 PANEL 125A SECOND LEVEL I 1003 I (TYP) PGE XMFR I MC 120/208 O 0 0 0 3-PHASE o 0 = 0 17,066 AFC800 A O O 0 0 0 HOUSE 0 0 0 0 0 0 0 PANEL O I 1003 I- 000000 = = = = \\\ 100A COMMERCIAL METER SOCKET 1/0 BARE CU TYP 1 00-AMP BREAKER RESIDENTIAL METER SOCKETS WITH - WATER PIPE 100-AMP BREAKER, TYP. UFER GROUND LEVEL PROJECT INFORMATION: SHEET TITLE REVISIONS SCALE NNTHREE 11490 SE Jennifer St MM/DD/YY REMARKS N/A--\---, PHASE Clackamas, OR 97015 RIVER TERRACE EAST I ' --/--/-- ,� i w ELECTRICDennis Welch ONE~LINE DIAGRAM 12 __/__/__ SHEET . �` CCB # 162368 2 1 -UNIT BUILDING F 3398S METER LOCATION 13 v_/---/-- PORTLAND, OR 14 --/--/-- E 4. 00 15 ---/----/--- 1 BEDROOM UNITSI15.2.201 PANEL) BEDROOM UNITS I DATE: 115.21018 PANE1.11 DATE: SERVICE: 1-PH, 3-WIRE, 120/208V RATING: 100 AMP MLO SERVICE: 1-PH, 3-WIRE, 120/208V RATING: 100 AMP MLO PANEL LOC: BEDROOM MOUNTING: FLUSH PANEL LOC: BEDROOM MOUNTING: FLUSH FED FROM: SEE ONE-LINE AVAIL FAULT: 10K* A1C FED FROM: SEE ONE-LINE AVAIL FAULT: 101 * AID CKT # LOAD DESCRIPTION CB POLES WATTS PH WATTS CKT # LOAD DESCRIPTION CB POLES CKT # LOAD DESCRIPTION CB POLES WATTS PH WATTS CKT # LOAD DESCRIPTION CB POLES 1 RANGE S 3700 A 1500 KITCHEN RECEPTACLE 1 RANGE 50 2 3700 A 1 00 2 KITCHEN RECEPTACLE 20 1 3 RANGE - - 3700 B 1500 4 KITCHEN RECEPTACLE 20 1 RANGE - - B KITCHEN RECEPTACLE 1 5 HEAT 15 2 1000 A 1080 6 DISHWASHER 20 5 HEAT 1 �� 080 D15HWASHER 0 1 7 7 V - - 1000 B 540 8 RECEPTACLES (AFCI) 15 - - B 080 RECEPTACLES AFCI} 15 1 9 BATH 20 1 300 A 1200 10t.1ICROWA', E 151 9 BATH 20 1 300 A 1200 10 MICROWAVE 15 1 11 LAUNDRY 15 1 1500 B 540 12 BEDCROOM (AFCI) 15 1 11 LAUNDRY 1 1 B BEDCROOMAFCI} 15 1 13 LIGHTS (AFCI) 15 1 200 A 2200 14 CLOTHES DRYER 30 13 LIGHTS AFCI} 15 1 A X00 1 CLOTHES DRYER30 2 15 LIGHTS (AFCI) 15 1 200 B 2200 16 CLOTHES DRYER - - 15 LIGHTS (AFCI) 15 1 400 B 2200 16 CLOTHES DRYER - - 17 RECEPTACLES AFCI} 15 1 A 500 18 HEAT 1 17 RECEPTACLES (AFCI) 15 1 1080 A 500 18 HEATER 15 2 19 AC RECEPTACLE (AFCI) 15 1 �, 19 HEAT 15 2 500 B 500 20� B 500 20 - - 21 " - - 500 A 840 AC RECEPTACLE (AFCI) 15 1 21 SPACE A 22 SPACE 23 SPACE B 24 SPACE 23 SPACE B SPACE NOTES: A 1 0 WATTS TOTAL CONNECTED LOAD 24.740 WATTS 118,9 AMPSNOTES: A = 14.300 WATTS TOTAL CONNECTED LOAD 27.220 WATTS 130,9 AMPS * t.1 U ST SERIES RATE yam MAIN GEAR B = 1�.5�0 WATTS TOTAL DEMAND LOAD 18.133WATTS 87,2 AMPS * 1.1 B ST SERIES RATE WITH MAIN GEAR B = 12.920 WATTS TOTAL DEMAND LOAD 19.123 WATTS 91 ,9 AMPS PANEIJ3 BEDROOM UNITS I DATE: 115.2.2018 I PANELIHOU E I DATE: 111121017 I - SERVICE: 1-PH, 3-WIRE, 120/208V RATING: 100 AMP MLO SERVICE: 3-PH, 4-WIRE, 120/208V RATING: 100 AMP MLO - PANEL LOC: BEDROOM MOUNTING: FLUSH PANEL LOC: ELECTRICAL ROOM MOUNTING: SURFACE FED FROM: SEE ONE-LINE AVAIL FAULT: 10K* AIC FED FROM: SEE ONE-LINE AVAIL FAULT: AIC CKT # LOAD DESCRIPTION CB POLES WATTS PH WATTS CKT # LOAD DESCRIPTION CB POLES CKT # LOAD DESCRIPTION CB POLE WATTS PH WATTS CKT # LOAD DESCRIPTION CB POLE 1 RANGE 50 2 3700 A 1500 2 KITCHEN RECEPTACLE 20 1 1 OUTSIE LIGHTS 20 1 600 A 800 2 2ND & 3RD FLOOR LIGHTS 20 1 3 RANGE - - 3700 B 1500 4 KITCHEN RECEPTACLE 20 1 3 1ST FLOOR LIGHTS 20 1 350 B 800 4 EWH-1 20 2 5 HEAT 15 2 1000 A 1080 6 DISHWASHER 20 1 5 FACP 20 1 200 C 800 6 V - - 7 V - - 1000 B 1080 8 RECEPTACLES (AFCI) 15 1 7 STAIR LIGHTS 20 1 600 A 180 8 TELCO M RECEPT 20 1 9 BATH 20 1 300 A 1200 10 MICROWAVE 15 1 9 GARAGE LIGHTS 20 1 420 B 180 10 UTIL RECUT 20 1 11 LAUNDRY 15 1 1500 B 540 12 BEDCROOM (AFC') 15 1 11 GARAGE LIGHTS 20 1 420 C 12 SPACE 13 LIGHTS (AFCI) 15 1 400 A 2200 14 CLOTHES DRYER 30 2 13 SPACE A 14 SPACE 15 LIGHTS (AFCI) 15 1 400 B 2200 16 CLOTHES DRYER - - 15 SPACE B 16 SPACE 17 RECEPTACLES (AFCI) 15 1 1080 A 500 18 HEATER 15 2 17 SPACE C 18 SPACE 19 HEAT 15 2 500 B 500 20 V - - 19 SPACE A 20 SPACE 21 V - - 500 A 840 22 AC RECEPTACLE (AFCI) 15 1 21 SPACE B 22 SPACE 23 SPACE B 24 SPACE 23 SPACE C 24 SPACE 25 SPACE A 26 SPACE NOTES: A = 14.300 WATTS TOTAL CONNECTED LOAD 27.220 WATTS 130,9 AMPS 27 SPACE B 28 SPACE 29 t MUST SERIES RATE WITH MAIN GEAR B = 12.920 WATTS TOTAL DEMAND LOAD 19.324 WATTS 92,9 AMPS SPACE C 30 SPACE NOTES: A = 2.180 WATTS TOTAL CONNECTED LOAD 4.960 WATTS 13,8 AMPS * MUST SERIES RATE yam MAIN GEAR B = 1.560 WATTS TOTAL DEMAND LOAD 4.960 WATTS 13,8 AM PS C = 1.220 WATTS PROJECT INFORMATION : SHEET TITLE REVISIONS SCALE r-,"NNTHREE 11490 SE Jennifer St MM/DD/YY REMARKS N/A r i ifactPHASE RIVER TERRACE EAST 1 __/__/__ ii,:criii.) ELECTRIC Clackamas, OR 97015 CCB # 162368 Dennis Welch 2 1 -UNIT BUILDING F PANEL SCHEDULES 2 --/--/-- SHEET 3398S 3 -_/--/-- PORTLAND, OR 4 __/__/__ E 4. 10 5 --/--/__