Plans (21) BU P2018-00350 RECEIVED DEC 26 2018 CITY OF TIGARD BUILDING DIVISION ABBREVIATIONS : LEGEND OF SYMBOLS : GENERAL NOTES : ... ANGLE FAST FASTENER PIP POURED IN PLACE I 1. ALL WORK TO COMPLY WITH THE REQUIREMENTS OF THE AHJ AND THE @ AT FB FLAT BAR PJ PANEL JOINT DETAIL IDENTIFICATION �,. CURRENT EDITIONS OF LISTED BUILDING CODES. ANY BUILDING OFFICIAL, ika Alk f + AND FBO FURNISHED BY OTHERS PL PROPERTY LINE I "" SUBCONTRACTOR OR TRADES PERSON NOTING DISCREPANCIES SHALL NOTIFY THE XX ��� '\\ AXXX DESIGNER IMMEDIATELY UPON DISCOVERY. AB ANCHOR BOLT FD FLOOR DRAIN P. LAM PLASTIC LAMINATE AXXX i } �� A/C AIR CONDITIONING FDN FOUNDATION PLAS PLASTER 1, i 2. CONTRACTORS SHALL COORDINATE ALL REQUIRED INSPECTIONS BY TF-CITY ACT ACOUSTICAL CEILING TILE FE FIRE EXTINGUISHER PLYWD PLYWOOD SHEET WHERE DRAWN - -- AND ANY OTHER GOVERNING AUTHORITIES AREQUIRED. ACOUS ACOUSTICAL FEC FIRE EXTINGUISHER CABINET PR PAIR DETAIL DETAIL VIEW BUBBLE I 3. CONTRACTORS SHALL VERIFY AND CONFIRM EXISTING CONDITIOINSHOWN OR WOODBLOCK ARCHITECTURE, INC. AD AREA DRAIN FF FINISH FLOOR PREF1N PREFINISHED DETAIL IDENTIFICATIONIMPLIED ON DRAWINGS PRIOR TO THE START OF CONSTRUCTION OR ORDERING 107 SE WASHINGTON STREET, SUITE 250 MATCH PORTLAND, OR 97214 P 5D3.889.06D4 ADD ADDENDUM FHC FIRE HOSE CABINET PT PRESSURE TREATED 7 SHEET MATERIALS, AND NOTIFY THE DESIGNER OF ANY DISCREPANCIES. ADJ ADJACENT FIN FINISH PTD PAPER TOWEL DISPENSER i XXXXXX LOCATION PAPER 4. CONTRACTORS SHALL OBTAIN AND PAY FOR ALL TEMPORARY UTILITIES INCLUDING ADJT ADJUSTABLE FL FLOOR PTDR COMBINATION1 AXXX A.F.F. ABOVE FINISH FLOOR FLASH FLASHING TOWEL DISPENSER + RECEPTACLE ���--- SHEET WHERE DRAWN ELECTRICITY NECESSARY FOR CONSTRUCTION. AGG AGGREGATE FLUOR FLUOktSUtr4T PTN PAr. i i I ION 5. ALL CONSTRUCTION DEBRIS TO BE NEATLY STOCKPILED ON SITE UNTIL DISPOSAL. ALS AREA LIGHT STANDARD FO FACE OF PTR PAPER TOWEL RRtCt IACLE BUILDING Stu ILA MATCH LANE REFERENCE5. DEBRIS IS TO BE DISPOSED OF IN LEGAL MANNER AT A LANDFILL OR RECYCLING ALT ALTERNATE FOC FACE OF CONCRETE PVC POLYVINYL _ DETAIL IDENTIFICATION DETAIL IDENTIFICATION CENTER. NO DEBRIS IS TO BE DISPOSED OF IN LOCAL WASTE COLLECTION FACILITIES. ALUM ALUMINUM FOF FACE OF FINISH PVMT PAVEMENT CUT LINE - . CUT LINE - OFFICE COPY Aillb DEFINES 6. CONTRACTOR SHALL INFORM THE DESIGNER OF ANY AND ALREQUESTED ANDD ANODIZED FOM FACE OF MASONRY QT QUARRY TILE DEFINEST!`i'4F'�'iGARD APPROX APPROXIMATE FOS FACE OF STUD R RISER XX I THE XX THE DETAILED CHANGES. CONTRACTOR SHALL NOT PROCEED WITH REQUESTED CHANGES OR FOR CODE COMPLIANCE AXXX DETAILED AXXX ELEMENT DIRECTIVES WITHOUT PRIOR AUTHORIZATION FROM THE DESIGNER AND A Wm) L'1',I i ARCH ARCHITECTURAL FOTS FACE OF TUBE SECTION R. RADIUS ELEMENT CHANGE ORDER. Appro AUTO AUTOMATIC FRT FIRE RETARDANT I rccH i cu RA RETURN AIR �� SHEET �y r rLI .L �,r2AWN SHEET WHERE DRAWN OTC: I A.F.C. ABOVE FINISH CEILING FT FOOT OR FEET RB RUBBER BASE WALL SECTION DETAIL SECTION 7. CONTRACTOR SHALL PROVIDE STORAGE FOR ALL BUILDING MATERIALS IN remit* Ad .. to - 0gam/ ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS. Address: .- 1 13) BC BrJ110N/10F CURB FTG FOOTING RD ROOF DRAIN DETAIL XXL - -- DETAIL IDENTIFICATION Suite#= 'rte BD BOARD FURR FURRING REF REFERENCE _ IDENTIFICATION ,A8. ALL SUBSTITUTIONS MUST BE APPROVED BY DESIGNER, ALONG WITH WRITTEN B _ Date: B.F.F. BELOW FINISH FLOOR GA GAUGE REFL REFLECTED XX REQUESTS CONTRACTOR SHALL PROVIDE ALL INFORMATION REGARDING THE L�. XX AXXX XX SUBSTITUTION IN QUESTION, INCLUDING COST. VALIDITY OF PERMIT BITUM BITUMINOUS GALV GALVANIZED REFR REFRIGERATOR XX THE ISSUANCE OF A PERMIT BLDG BUILDING GB GRAB BAR REINF REINFORCED SHEET WHERE N.NSHEET WHERE DRAWN BASED ON CONSTRUCTION BLK BLOCK GC GENERAL CONTRACTOR RESIL RESILIENT DRAWN XX 9. SOLID WOOD BLOCKING, INSULATION, OR OTHER FIRE STOP MATERIALS IS TO BE DOCUMENTS AND OTHER DATA SHALL NOT PREVENT EXTERIOR ELEVATION INTERIOR ELEVATION PROVIDED, BETWEEN TOP STORY AND ROOF FACE. THE CODE OFFICIAL PR FROM BLKG BLOCKING GI GALVANIZED IRON REQ'D REQUIRED REQUIRING THE CORRECTION OFB.M. BENCH MARK GL GLASS REV REVISE OR REVISION 10. CONTRACTOR SHALL PROVIDE SAMPLE OF FINISHES AND STAIN COLORS FOR OF ERRORS.OSSC 105.4 B.O. BOTTOM OF... GL GLU LAM RM ROOM s APPROVAL BY DESIGNER. THIS INCLUDES INTERIOR AND EXTERIOR PAINT, AND BOT BOTTOM GND GROUND RO ROUGH OPENING ROOM NAME XX SHEET ROCK TEXTURES. BRG BEARING GP GALVANIZED PIPE RWL RAIN WATER LEADER XXX XXXX-A . TIGARD RED LIGHT TICKETS B.S. BOTH SIDES GRD GRADE RCP REFLECTED CEILING PLAN 11. WRITTEN DIMENSIONS AND NOTES ON DRAWING SHALL TAKE PRIORITY OVER SCALE BSMT BASEMENT GVP GYPSUM VENEER PLASTER S SOUTH ROOM NAME & NVIvr ER DOOR NUMBERS OF DRAWINGS. DO NOT MEASURE DRAWINGS TO DETERMINE ANY DIMENSIONS. BTWN BETWEEN GWB GYPSUM WALL BOARD SC SOLID CORE DRAWINGS ARE IN SCALE FOR PURPOSES OF DESIGN AND INTENT ONLY. ALL INTERIOR T.I. FOR CITY OFFICES BUR BUILT-UP ROOF GYP GYPSUM BOARD SCD SEAT COVER DISPENSER DIMENSIONS SHOWN PLANS ARE FROM AND TO FACE OF FRAMING OR FROM AND Tr] BPW BED PAN WASHER HB HOSE BIBS SCHED SCHEDULE CENTERLINE OF WALLS, UNLESS OTHERWISE NOTED. [ OR C CHANNEL HC HOLLOW CORE SD SOAP DrSr'tIVSER XX X 12. ALL FEATURES OF THE WORK NOT FULLY SHOWN SHALL BE OF THE SANTYPE CAB CABINET HC HANDICAP PARKING STALL SECT SECTION AND CHARACTER OF THAT SHOWN FOR SIMILAR CONDITIONS. IN THE EVENT OF THAT CB CATCH BASIN HDWD HARDWOOD SGE SEMI-GLOSS ENAMEL ADDITIONAL WORK IS REQUIRED TO COMPLETE THE WORK AS INTENDED OR CEM CEMENT HDWR HARDWARE SH SHELF WINDOW NUMBER EQUIPMENT TAG REQUIRED BY GOVERNING CODES, YET NOT FULLY SHOWN OR OMITTED BY IN THE CFI CONTRACTOR FURNISHED HM HOLLOW METAL SHTG SHEATHING DRAWINGS, CONTRACTOR'S) MUST STILL PROVIDE FOUNDATION, CARPENTRY, MECHANICAL, ELECTRICAL AND OR/ PLUMBING AS REQUIRED FOR CERTIFICATE OF AND INSTALLED HORIZ HORIZONTAL SHWR SHOWER OCCUPANCY, INCONSISTENCIES, OR DISCREPANCIES. CG CORNER GUARD HR HOUR ONLY SHT SHEET C.I. CONTRACTOR INSTALLED H. HEIGHT SIM SIMILAR 13. VcrIr Y ALL DIMENSIONS AND MFR. SPECIFICATIONS OF OWNER FURNISHED XX I \ EQUIPMENT PRIOR TO CONSTRUCTION. CI CAST IRON HVAC HEATING 1 VENTILATION 1 AIR SJ SEISMIC JOINT ,� CENTER LINE CONDITIONING SL SLIDING PROJECT TEAM DRAW ING INDEX 14. DO NOT SCALE DRAWINGS. --I-- CLG CEILING HW HOT WATER SM SHEET METAL KEY NOTES WALL TYPE SHEET # SHEET TITLE CLOS CLOSET ID INSIDE DIAMETER (DIM.) SND SANITARY NAPKINDISPENSER __.. CLR CLEAR INSUL INSULATION SNT SANITARY NAPKINRECEPTACLE CLIENT: CITY OF TIGARD A000 COVER SHEET 13125 SW HALL BLVD CJ CONTROL JOINT INT INTERIOR SPEC SPECIFICATION BIDDER DESIGN M EC HAN I CAL TIGARD, OR 97223 A002 ACCESSIBILITY CMU CONCRETE MASONRY UNIT INV INVERT SQ SQUARE Level 1 CONTACT: JUSTIN JAMES PIPE SIZE SS STAINLESS STEEL 0'-0" AFF Al OO FLOOR PLAN COL COLUMN IPS IRON ELECTRICAL , AND PLUMBING A101 DETAILS COMP COMPOSITION JAN JANITOR S + V STAIN + VARNISH DATUM ELEVATION REVISION DELTA & CLOUD ARCHITECT OF RECORD: WOODBLOCK ARCHITECTURE CONC CONCRETE JT JOINT STA STATION CRITERIA 827 SW 2ND AVE, STE 300 CO CONCRETE OPENING JST JOIST STD STANDARD - - PORTLAND, OR 97204 CONN CONNECTION KIT KITCHEN STK STOCK 1. ALL MECHANICAL, ELr-I; i rciCAL, AND PLUMBING WORK SHALL BE PROVIDED UNDER P: 503.889.0604 CONST CONSTRUCTION KD KILN DRIED STL STEEL A SEPARATE CONTRACT AND PERMIT. SUBMITTALS SHALL BE DEFERRED CONTACT: JONATHAN DUNN XX 00,-00" -- E: JONATHAN@WBLOCK.COM CONT CONTINUOUS L. LENGTH STOR STORAGE i CONTR CONTRACTOR LAB LABRATORY STRUCT STRUCTURAL - 2. IT IS THE DESIGN/BUILD CONTRACTOR'S RESPONSIBILITY TO CONFORM TO ALL APPLICABLE BUILDING CODES AND TO PROVIDE ALL DOCUMENTATION REQUIRED SUSPENDED CORR CORRIDOR LAM LAMINATE SUSP FINISH TAG CEILING HEIGHT TO OBTAIN PERMITS FOR WORK UNDER THEIR CONTRACT. CR CONTRACTOR ROUGH-IN LAV LAVATORY SYM SYMMETRICAL 1 CRRR CONTRACTOR REMOVED, LB LAG BOLT SYST SYSTEM ---- 3. THE OWNER AND DESIGNER ARE NOT RESPONSIBLE FOR ADDITIONAL COSTS RELOCATED + REINSTALLED LDW LESS DOOR WIDTH T TREAD INCURRED DUE TO DESIGN/BUILD CONTRACTOR'S ERROR AND OMISSIONS. TIGARD RED LIGHT CS COUNTERSUNK L.I. LANDSCAPE ISLAND TB TOWEL BAR — —0-0r \00'-00'1 , XX-XX) \ CS.J CONSTRUCTION JOINT LKR LOCKER T + B TOP AND BOTTOM \ 4. ELECTRICAL DESIGN CONTRACTOR WILL COORDINATE POWER, SIGNAL AND 13215 SW Hall Blvd LIGHTING DESIGN AND PROVIDE CALCULATIONS IN CONFORMANCE WITH STATE PROJECT DATA Tigard, OR 97223 CSMT CASEMENT LL LIVE LOAD TOC TOP OF CURB ELECTRICAL CODE, ENERGY CODE AND BUILDING CODE. CT CERAMIC TILE LS LANDSCAPING TEL TELEPHONE SPOT ELEVATION FINISH HEIGHT & TYPE CTR CENTER LT LIGHT TEMP TEMPERED 5. ELECTRICAL DESIGN CONTRACTOR WILL REVIEW THE PROGRAM DRAWING AND LVR LOUVER T + G TONGUE AND GROOVE - - WILL MEET WITH THE TENANT TO FINALIZE THE EXACT POWER LOCATIONS AND BUILDING CODES: 2014 OREGON RESIDENTIAL SPECIALTY CODE (ORSC) CW COLD WATER REQUIREMENTS FOR EQUIPMENT. DESIGN WILL PROVIDE FOR CODE REQUIRED 2014 OREGON MECHANICAL CODE (OMC) DBL DOUBLE MAT'L MATERIAL THK THICK TO AND MAINTENANCE RECEPTACLES. DESIGN WILL INCLUDE FIRE ALARM SYSTEM IF 2011 OREGON PLUMBING CODE (OPC) DEMO DEMOLISH MAX MAXIMUM TJ TOOL JOINT Cr-0" REQUIRED, COORDINATED AND EXTENDED FROM BUILDING FIRE ALARM SYSTEM. \ 2014 OREGON FIRE CODE (OFC) DEPT DEPARTMENT MB MACHINE BOLT TP TOP OF PAVEMENT `+� OUTLETS, PHONE AND DATA JACKS SHOWN ON ARCHITECTURAL PLANS (IF ANY) 2014 OREGON ELECTRICAL CODE (OEC) DF DRINKING FOUNTAIN MC MINERAL CORE TPD TOILET PAPER DISPENSER ARE MINIMUM REQUIRED AND MAY NOT INCLUDE ADUI-I ZONAL OUTLETS REQUIRED ZONING: MU-CBD MIXED USE - CENTRAL BUSINESS DISTRICT DIA DIAMETER MDO MEDIUM DENSITY OVERLAY TPD(S) SURFACE MOUNTED START POINT TOP OF MARK BY CODE OR FOR MAINTENANCE. CONSTRUCTION TYPE: V-B DIAG DIAGONAL MECH MECHANICAL TOILET PAPER DISPENSER 6. ELECTRICAL DESIGN CONTRACTOR WILL COORDINATE HIS WORK WITH THE DIM DIMENSION MED MEDIUM TS TUBE SECTION ARCHITECT AND WITH THE HVAC AND FIRE SPRINKLER DESIGN/BUILD DISP DISPENSER MEMB MEMBRANE TV TELEVISION CONTRACTORS. MEZZ MEZZANINE TOW TOP OF WALL EXTENT OF D.JT DEFLECTION JOINT . 7. ELECTRICAL DESIGN CONTRACTOR WILL MEET WITH THE TENANT TO DETERMINE Project #18-115 DL DEAD LOAD MFR MANUFACTURER TYP TYPICAL WORK AND/OR CONFIRM THE LOCATION OF ALL DATA AND COMMUNICATION DMT DEMOUNTABLE MH MANHOLE UNFIN UNFINISHED CONNECTIONS REQUIRED AND INCLUDE CONDUIT TO 6" ABOVE FIN CLG. BOX AND DN DOWN MI MALEABLE IRON UR URINAL EXTENT OF WORK DATUM INDICATOR PULL STRING IN THE REQUIRED LOCATIONS UNDER THE T.I. CONTRACT. DO DOOR OPENING MIN MINIMUM U/CUT UNDER CUT DP DAMPkOUriNG MIR MIRROR U.N.O. UNLESS NOTED OTHERWISE 1 /� 8. CONFIRM LIGHTING SWITCHING REQUIREMENTS WITH OWNER DR DOOR MISC MISCELLANEOUS VB VAPOR BARRIER 9. CONSTRUCTION AND AS-BUILT DRAWINGS TO BE PROVIDED ON ELECTRONIC DS DOWNSPOUT MO MASONRY OPENING VERT VERTICAL \/ MEDIA, AUTOCAD RELEASE 14 OR LATER, TO THE ARCHITECT FOR THE OWNER'S a) DSP DRY STANDPIPE MTD MOUNTED VEST VESTIBULE RECORDS. DT DRAIN TILE MTL METAL VFY VERIFY11511\ TRUE NEW GRID EXISTING = MULL MULLION VG VERTICAL GRAIN NORTH GRID 10. ELEC I'klUAL DESIGN/BUILD CONTRACTOR SHALL BE RESPONSIBLE TO VERIFY ALL DTL DETAIL ›, MEDCAB MEDICAL CABINET W WEST NORTH ARROW GRIDLINE BUBBLE DEVICES, INCLUDING BUT NOT LIMITED TO: STROBES, ANNUNCIATERS AND EGRESS JONATHAN H. DUNN, 5 DWG DRAWING LIGHTING, REQUIRED BY ALL APPLICABLE CODES. POWER AND LIGHTING ARCHITECT 0 DIAMETER OR ROUND N NORTH W. WIDTH — NON - RATED DRAWINGS INCLUDED IN THIS DOCUMENT ARE FOR DESIGN PURPOSES ONLY. ANY �, NA NOT APPLICABLE W/ WITH VICINITY MAP PROJECT SITE E EAST 1-HOUR RATED DEVICE REQUIRED BY CODE OR BY BUILDING OFFICIAL AND NOT INCLUDED IN BID SET Lr) EA EACH NAT NATURAL WC WATER CLOSET 2-HOUR RATED ELECTRICAL DESIGN/BUILDERS BASE BID SHALL BE INSTALLED AT THE ELECTRICAL 11.05.18 EF EACH FACE NIC NOT IN CONTRACT W.D. WINDOW DIMENSION 3-HOUR RATED DESIGN CONTRACTOR'S EXPENSE. REV DESCRIPTION DATE --_ _ -- - - - x 4 Regal Cinemas Tigard 11 E.AGG EXPOSED AGGREGATE NO. OR # NUMBER WD WOOD _ - 4-HOUR RATED i g sw4'e.„, g 12 © ) A swr. TD EJ EXPANSION JOINT NOM NOMINAL WF WIDE FLANGE EXIT SIGN —,..,„ 9 sw © I g r Costco who sole �r Wlnco Foods v NS NELSON STUD WG WIREGLASS PARTITION FIRE RATINGS e EL ELEVATION d .. NTS NOT TO SCALE WH WATER HEATER �A f oR M.. ELEC ELECTRICAL yY See gwe„I".,._, Et ELEV ELEVATOR NIS NOT IN SHELL ISSUE WDW WINDOW MATERIALS s» ¢ry"W y�*+ walmart5opercenter9 ; i �; w = EOS EDGE OF SLAB OA OVERALL W/O WITHOUT I t ? ; " AC O U S T I CA WOOD �� ,,, SW r,,kIn. ENCL ENCLOSURE OBS OBSCURE WP WATERPROOF II I III L o-.�� GRAVEL MEMBER �” ,TC%NESE] `` v� SNe.,.l.nn91 on,-, � U OC ON CENTER WRB WEATHER RESISTANTBARRIER swrx" "�w. �r' %, c'�g"ne°4 ms ENGR ENGINEER TILE SIVinceMoew!Tigard® s '.� OD OUTSIDE DIAMETER WRGB WATER RESISTANT GYPSUM �/ ALUMINUM — GYPSUM - - EP ELECTRICAL PANEL j%//� BOARD �r� M, `i i i i EQ EQUAL O.F. OWNER FURNISHED BOARD �""°"^•.� (.4 �; w, -, AacificParkwayCenterQ Ln EQUIP EQUIPMENT O.F.C.I. OWNER FURNISHED WW WATERSTOP 7SNSM INSULATIO g.>< PLYWOOD �� o' C1 "ell y o Portland Oregon Temple Co OFF OFFICE WSCT WAINSCOT South d ES EACH SIDE ■ri RIGID �n ,e^c ^ City Park woo DEFERRED SUBM I I ALSeY. ,w .1 EW EACH WAY OH • OVERHEAD WT WEIGHT�CTOR INSTALLED CMU OR BRICK �.�..ii INSULATIO a > I 9, a r.•rek P �,� 'III■ I Y, OPNG OPENING WWF WELDED WIRE FABRIC "� HVAC _ �� �.S" m EDF ELECTRIC DRINKING SOUND .M,.�� 'AY Chary FOUNTAIN OPP OPPOSITE o 4 _ Q CONCRETE INSULATIO ELECTRICAL .,l.st a PLUMBING " "Merl p ''� Q aet' LIJ EXIST EXISTING —J ‘ 05 OUTSIDE N OFI OWNER FURNISHED -INSTALLED r EARTH STEEL FIRE ALARM 'w`°°,.I�� = O�weooGrlll� I N A FIRE SPRINKLER ti� c� k. Walgreens 0 Q Gnodw+ll ThriN Store �d � Y W � EXP EXPANSION N PAR PARALLEL .._. ..._.... swcwd.g Ti9aTa swMctlm.ld9 SWMc��eld3, S4VMcllonald9l °�nvLnyk pllveGarden Hellen Q U N EXT EXTERIOR PC PRECAST nk WOODED BLOODING u...�..eA000 cv FA FIRE ALARM 8 COVER SHEET cc 00 CITU OF TIGARD 8 Approved by Planning © Date: i2-L6-1 Initials: Sc - 24" PULL SIDE CLEAR AT MIN EXTERIOR DOORS 36" MIN. • , 18" , CLEAR AT )/ f r MIN. ' INTERIOR DOORS ////// /////'////////%//� �/////// I///////////////////////////////////A 13'13)._ (1 I '=11{ b WOODBLOCK ARCHITECTURE, INC. > r 1I f ' co \ 107 SE WASHINGTON STREET, SUITE 250 PORTLAND, OR 197214 I P 503.889.0604 PULL SIDE PULL SIDE *1% ' //////// I '////////////////////j : . +////////////,I N [777Z //////////////////////,l '1.:..i )- 6 , , a) _ 'I PUSH SIDE :., / PUSH SIDE . /i ^ IV//////////////////////////////////////// Ci'//////////////////////////////////4 r12"/ 48"MIN. IF DOOR 48" MIN. IF DOOR 22" MIN. HAS BOTH A LATCH HAS BOTH A 24" MIN PUSH SIDE . '� / ?,.e-\_,4 ANDA CLOSER CLOSER ,• A 12" IF LATCH AND MIN. HINGE PROVIDED 0 FRONT APPROACH (BD HINGE APPROACH LATCH APPROACH 0 LEVEL MANEUVERING CLEARANCE AT DOOR SCALE: 114" = 1 '-0" Ce DOOR CO PULL SIDE PUSH SIDE __, 48" MIN. ; WIDTH . /////////////////////////////� /////////,��i i`//////� / ,-5'=0"CLEAR•. ,,. i i ,�ril / ,\ \\TN--------_____7 6��AG7Vp 4 lk , f 4:1111111:i 0 % y' LEVEL AND �� CLEAN 24" \\\---------- MIN. BEYOND THE STRIKE EDGE / '''.. 4111. lie:011>1.--4/. il / o OF GATE OR DOOR ON THE SIDE / i : j yz. �� / TOWARD WHICH IT SWINGS j CI) • / / /////////////// • �/ //// • / V////////////////� //////////moi IV///,////// r" /// V////////////7 '// //////// /,, C„ DOORS IN SERIES 0-3) DOORS AT ADJACENT WALLS i• • ix .7 5-0' DOOR DOORCe 111- o WIDTH 48" MIN. WIDTH co /////iii/////// • / X=6" IF DOOR HA ,ie CLOSER AND 6" FOR v 1 I✓i ///////////////////4///////// 0 A LATCH FRONT APPROACH - SLIDING AND ' FRONT APPROACH SWINGING DOORS B FOLDING DOORS 4,..,--,,• _•.,,i z k� 111 2 PULL SIDE PUSH SIDE I I , o el, X rn r r 60" MIN. I ITo 14'-6" 5'-0"TURNING DIA MANEUVERING , 12" MIl. * 22" MIN. 22" MIN. v r CLEARANCES AT 0t' / • / I DOORS 11 /////////////// s c * � d//i//////////////////////// z - - _` . 32" MINIMUM 4110 i 2 4 BOTH DOORS OPEN OUT Er D DOORS AT OPPOSITE WALLS -. it �� CLEAR OPENING 5 0 ›. Ali 7 URAMP LANDING AT D 00 RWAY V E TI BU LE '— " ' ' S S Il +, �, _____----- ACCESSIBLE j /////////1 Y///// ////_ //////I 7/1r (/////////,16 0 -0 _ COMPARTMENTS 32" MIN- 32' MIN / I . SCALE: 1/4" = 11-0" SCALE: 114 - 1 -0 ,„ bo CLEAR, TYIC R, TY' r , 16"MIN. `'' 18"MAX. X=36" MIN. IF Y=60" "Y=48" MIN. IF DOOR /////////,4`/////////1,//////// 16" MIN 2'-6" 60" x 56" CLEAR X=42" MIN. IF Y=54" HAS BOTH A / i�� / I I ,� 4 y CLOSER AND LATCH. SPACE AT TOILET / / 32" MIN. „ 32" MIN. '� -�� " TIGARD RED LIGHT = ti30 x 48" MIN CLEAR le) HINGE SIDE APPROACH SLIDING AND �N / r 0 HINGE SIDE APPROACH - SWINGING DOORS D FOLDING DOORS / .� / r SPACE AT LAVATORY TICKETS / "///////// , \ 13215 SW Hall Blvd PULL SIDE PUSH SIDE /i % / % .► Tigard, OR 97223 24" A 2 -11,7 ,) �r MIN. ,, 24" , 24" -le / / / '� MIN. MIN. / /.z x (�, ;/ ......; , 36'GRAB BAR z �` . . 1 36" MIN. 1 48" OR , 38" MIN. , - ,- „ �_ 42" n n n J S p GRAB BAR z GREATER CHANGE IN LEVEL , I ' o 90° TURN SCALE d"- 1'-0" SCALE: FULL SIZE HINGED DOOR SLIDING DOOR �, u N A B OA B 1 li ///// ////////////// V/V/ L////////i/1 r/v/r/////' t \ IrJ"//j ////2///i,i ---------') / �, i " {:' r 1 / r 32 MIN. _ __,----) .,,, *Y=54" MIN. IF DOOR *Y=48" IF D kr 4$ �� �. 32" MIN.HASACLOSER HS A CLOS ��/ to / *r �` / N •,... .______ LATCH SIDE APPROACH - SLIDING AND \ / o I'//////4 I'//////f 1 Project #18-115 0 LATCH SIDE APPROACH SWINGING DOORS FOLDING DOORS / / j it t,i 1 1 r'� f jNOTE:di)1121))11)))))))))! FOR LOCATION AND MOUNTING HEIGHTS NOTE: ALL DOORS IN ALCOVES SHALL COMPLY 42" MIN. 1, 42" MIN. OF ACCESSORIES SEE TYPICAL MOUNTING ." HEIGHTS THIS DRAWING -SEE DETAIL 14 WITH THE CLEARANCES FOR FRONT APPROACHES LESS THAN 48" CHANGE IN LEVEL (C TURNS AROUND AN OBSTRUCTION i..1 SCALE: FULL SIZEFOLDING DOOR ii MAXIMUM DOORWAY DEPTH -= DOOR ACCESS CLEARANCE ACCESS ROUTE REQUIRED CLEAR DOORWAY DIMENSIONS TYPICAL ACCESSIBLE CLEARANCES 9 1O (ID • = SCALE: 114" = 1 '-0" SCALE: 114" = 1 '-0" SCALE: 114" = 1 '-0" SCALE: 114" = 1 '-0"' a JONATHAN H. DUNN, Uw ARCHITECT ca a) BID SET �1 NOTE: 11 .05.18 1-112"CLEAR BETWEEN GRAB REV DESCRIPTION DATE as BAR AND WALL- SEE DETAIL 13 �1315" MIN /- a) 13 1 112" EDGE / ,r v, 39"- 41"CENTER SINK TO F c& v GRAB BARS AUTO-FLUSH f CL OF COAT HOOK 1-1/4" • •, , ... , TO 1-112" - " WHERE NOTED f� DISPENSER Te — 12" 42 cn = DIA NOMINAL - �`_,,, 6'y 36' MIN G . 8 _ • \• " 4 E -J_I- L 0 C r° • C 0 . o o n it..... Lcy, ill _ 3 " W re OW W Z �-0 " ~,_ W f% T � 4 Z 1 J � LID IN OPEN. m cn r,..7 ik B 'i Fr 0 cL a w w w m 2 c� z = __ F-- Z 0 D = ca Lt POSITION °? °� u, 7 " _ *�_.� w M z ~- = N NAPKIN 1 11 0b I— .CI- J " o g _ a. o - a gt o BACKING AT GWB, FRP, _/4 0 v ; 01111404.0.6111111111MA M} J 0 "' o OR TILE N TAMPON m , _ ra ti o ° O o - . DISPOSAL F--- a _ .... ► , • �� 1- , • 42" M /FLOOR-MOUNTED I • • V • \FACE OF WALL 'PAPERf 18" MIN TO OUTLET WALL-MOUNTED INSULATE EXPOSED 1''5" 16"T018" BOTTOM OF MIRROR INSULATE EXPOSED LAIR DRYER DISPENSER 48MAX TO OUTLET WHERE SHOWN PIPES AND HOT AND MIN REFLECTIVE SURFACE PIPES AND HOT AND re D N COLD SUPPLY LINES COLD WATER SUPPLY w N (11) GRAB BAR TYPICAL ACCESSI BLE MOUNTING HEIGHTS AND CLEARANCES LINES 12& U T- SCALE: 6" = 1 '-O" SCALE: NOT TO SCALE 1213,.., I 4cc, m ACCESSIBILITY a © \I WOODBLOCK ARCHITECTURE, INC. 107 SE WASHINGTON STREET, SUITE 250 PORTLAND, ORE 97214 I P 503.889.0604 <> 1 <--.> /1 / / . GLASS DIVIDER (II) GLASS DIVIDER GLASS DIVIDER ` 2,I N\ CO Ce /� EQ. �' EQ. / 6" TRIM, 2" SETBACK FROM \ I ./ N- COUNTER EDGE. SUPPORT _ AS NEEDED. EMII iV r Co I ich b i Cliii) Z 1 �f q 0 �� MCC _I 51 l �� 3' - 8" 3' - 8" / / / / 0 1 TRANSACTION WINDOW •\ \• S.S. DEAL TRAY. TO ACCOMODATE 8.5" x 11" SHEETS OF PAPER, TYP. 0 1 1 5 COUNTER ENLARGED PLAN 4 COUNTER FRONT Ce SCALE 1112 = 1 -0 SCALE 13/4 = 1'-0" 0 11 1 p /\./ N ,..., ....... 1 .,-----> „----> TIGARD RED LIGHT TICKETS 13215 SW Hall Blvd Tigard, OR 97223 FRAME TO BOTTOM OF JOISTS -.- r' , V Project #18-115 3 - 3" (E) SOFFIT (E) SOFFIT 518" GYP BOARD EA SIDE, TYP. - (E) COLUMN WRAP (E) COLUMN WRAP =Tom. L,1 \ IL L-J \• \• - I a.) LAMINATED SAFETY GLASS SHATTERPROOF GLASS j 3505162-33 MTL. STUDS . 1= TRANSACTION WINDOW, NO TRANSACTION WINDOW, NO co WIRE. WIRE. SEE WINDOW AT POLICE ! COUNTER FOR SIM CONDITION. w JONATHAN H. DUNN, U o `'� 4„_, ARCHITECT 12 1 \/\ . .`1. cu ' BID SET i— TRANSACTION COUNTER. M 11.05.18 I `C) WATERFALL EDGE AT r REV DESCRIPTION DATE TRANSITION TO ADA HT. is f, 1 5/8" GYP BOARD EA SIDE, TYP. 4" 1' - 2" ZO iC / ' /1 \ To 1/2" PLYWD SHEATHING , I ` _›, 4" 1' - 2" U 600S162-33 MTL. STUDS 5/8" GYP BOARD EA SIDE, TYP. / ,I,' cc7 -[ r LU I -,' ! " 1/2" PLYWD SHEATHING o 0 x D1:'-'::' cO N N .- 6005162-33 MTL. STUDS I , N LL - - LU - L 'A. .1. %. • Q5 w N N Ai 0 1 ci N cc, U r0 J N 3 SECTION @ COUNTER2_ SECTION @ ADA COUNTER _TYPICAL WALL DETAILS Lc, SCALE 1314" = 11-0" SCALE 1314" = 1'-0" SCALE ' 3" = 1'-0" i 0 L VV J J L J I 4 WOODBLOCK ARCHITECTURE, INC. 107 SE WASHINGTON STREET, SUITE 250 p 112 1 PORTLAND. OR I 97214 I P 503.889.0804 I � � � 1 I 4, 0 ) _ 117 BID ALTERNATE : L 119 ( 5 . I IT 103 A1001) 0 _._ ,' -- ---'-'. FOR ALL NEW FLOORING AND COUNTER IN d .= 4� 106 106 106 EMPLOYEE LOUNGE I - 4. 0 1113 4 4I c 2' - 9�� 9' - 3U 2' - 9" 9' - 3" 2' - 9" l‘i 1 ELECTRICAL ROOM UPSTARTS. I a 4 rip fl I, - - - - - - - - Ip N V 3 - S le 3 - 8 / I1 1 IiII n 115e / t , LEI1 D 1 . 4y G ° a � d1 - ' I - — _ = a 109 118 = I 4 I o 105 j32) I - . . I losin s. KEYNOTE LEGEND a - a 4 - Z i 104 i I '� I 100 N FULL HEIGHT WALLS TO BOTTOM OF JOISTS . . -110 � a \2 - Ce I - d .-.e . 4 :4a' • a ' A101 A101 I 101 (N) LED LIGHTING DD108I ri . . a4 : °• 109 4' - 4 112" 25' — 4 112" 1 102 . (N) CARPET IN CORRIDORS AND NEW OFFICE AREAImimi a - : a' .` _ _ 1 103 l (N) WALL AND 3'-0" DOOR WITH ELECTRONIC ACCESS, 1 d � � _ _ � (----- ic, I • 4 116 I RELOCATED PER ADA 404.2.4. 1CO Q a 4 ., a 101 - - r I 1 d . •. 104 DEMO EXISTING WALL AND DOOR TO BE RELOCATED FOR _ _ J . . 4 I I7 ADA 105 DEMO EXISTING WALL, OVERHEAD DOOR, AND COUNTER TO I \\\\ C0 I , �� 111 e a 02 I I0 N I BE REPLACED WITH NEW TRANSACTION WINDOWS. 2 • 0 STATIONS PER BAY, 1 ADA ACCESSIBLE TOTAL. WATERFALL 0 \\ _ a o d6. J TRANSITION FROM STANDARD TO ADA COUNTER HT. I COUNTER FINISHES TO MATCH EXISTING, CONFIRM WITHCI) L � CITY. 106 DEMO (E) COLUMN WRAPS AND BUILD NEW WI POWER AND I I 0 � DATA FOR FUTURE TABLETS EACH SIDE, TYP. REPLACE SOUND ATTENUATION. REMOVE ACT TILES FROM Ce 1 107 7 I UNDERSIDE OF SOFFIT, PATCH OR REPLACE GYP AS 100 I SCOPE OF WORK AREA i NEEDED. 1 107 (N) 3'-0" DOOR WITH ELECTRONIC ACCESS 1 A101 0 6' ' OII ALIGN 1 108 (N) WALL WITH SOUNDPROOF INSULATIONLlim N. I I I 1 IN 109 DEMO (E) WALL I I 16' - 61/2" 110 DEMO (E) FLOORING AND POLISH EXISTING CONCRETE I- 111 (N) WALK-OFF MAT I COMMON PATH = 53'-5" _ Jr L I � 112 (N) STRAIGHT SOFFIT BUILT OVER (E) SOFFIT W/ (N) CAN I �� 102 I LIGHTS0 L J 113 DEMO (E) DESK AND WINDOW 115 FLIP (E) DOOR HINGE TO OPPOSITE SIDE TO COMPLY WITH 0 ADA CLEARANCES - 0 0 116 DEMO (E) DOOR AND INFILL OPENING. MATCH EXISTING WALL FINISH, BOTH SIDES. 117 (N) WALL WITH 2 TRANSACTION WINDOWS W/ GLAZING - _ _' BETWEEN. 1 ADA COUNTER. ALIGN WITH (N) SOFFIT ABOVE. 0 . I o 118 (N) CLOSET DOOR TIGARD RED LIGHT 0 ----_____. 119 DEMO (E) COCUMN IF POSSIBLE. FURTHER INVESTIGATION TICKETS IS REQUIRED. 13215 SW Hall Blvd Tigard, OR 97223 - GENERAL NOTES 1 . ALL NEW WALLS TO BE 3-5/8" MEATL STUDS W/ 5/8" GYPSUM WALL BOARD UNLESS OTHERWISE NOTED. 0 0 0 0 0 0 - 2. RELOCATE ELECTRICAL SWITCHES AS NEEDED TO ACCOMODATE NEW WORK 3. MAINTAIN EGRESS LIGHTING 4. ALL TRANSACTION WINDOWS TO HAVE SECURE SLIDERS, GLAZING TO BE LAMINATED TEMPERED GLASS MIN 114" THICK (OR APPROVED EQUAL), NO WIRE IN GLASS. GLAZING BETWEEN SECURE SLIDERS. _ 0 5. NEW ELECTRICAL AND DATA HOME RUNS TO ACCOMODATE NEW WORK. EACH WORK STATION TO HAVE POWER AND 3 DATA PORTS. Project #18-115 SERVER ROOM 0 6. NEW HVAC WORK AS NEEDED, COORDINATE WITH INTEGRATED CONTROLS 1 0 0 0 0 0 --) 1 FIRE EXTINGUISHER NOTES I 1 . LOCATE FIRE EXTINGUISHERS (SOIC) AS DIRECTED BY FIRE MARSHALL 2. FIRE MARSHALL SHALL DETERMINE SIZE AND TYPE OF EXTINGUISHERS a) i."----0 . . 3. IN GENERAL. PROVIDE: T a. ONE 2A: 10 BC FIRE EXTINGUISHER PER 3,000 SF AREA WITHIN _ 75 FOOT MAXIMUM TRAVEL DISTANCE JONATHAN H. DUNN, _ _I __ I_ --- b. CLASS K FIRE EXTINGUISHER WITHIN 30 FEET OF COMMERCIAL ARCHITECT 0-2 �' FOOD HEAT PROCESSING EQUIPMENT c. COMPLY WITH NFPA 10 BID SET _j v 11 .05.18 : Kd. PORTABLE FIRE EXTINGUISHERS DURING CONSTRUCTION 1 - WHERE REQUIRED BY 2012 IFC SECTION 3315. Lo REV DESCRIPTION DATE EXIT ACCESS 73 FULLY SPR1NKLERED TYPE B OCCUPANCY IN ACCORDANCE WITH SECTION 903.3.1 .1 ALLOW TRAVEL DISTANCE OF 250'-0" TO EXIT ACCESS. c m MAXIMUM TRAVEL DISTANCE FOR TENANT SPACE TO EXIT DISCHARGE IS 125'-0" i li ES EGRESS GENERAL NOTES, G 1 . A MINIMUM OF 1 .0 FOOT-CANDLES SHALL BE MAINTAINED OVER cz THE ENTIRE EGRESS PATH. THE BUREAU INSPECTOR WILL METER THE LIGHT LEVELS PROVIDED BY THE INSTALLED tr, SYSTEM. THE CONTRACTOR IS RESPONSIBLE FOR THE DESIGN INSTALLATION, REQUESTING INSPECTIONS, AND MAKING 63 CORRECTIONS AS REQUIRED 2. ALL EMERGENCY LIGHTING, FIRE DETECTORS, COMMUNICATION N FLOOR PLAN - DEVICES AND ALL OTHER REQUIREMENTS TO CONFORM TO THE OREGON STATE BUILDING CODE SCALE 13116" = 1'-0" 3. GENERAL CONTRACTOR SHALL COORDINATE WITH THE o 2 BUILDING OWNER WHEN CONNECTING TO EXISTING SPRINKLER a_ AND ALARM SYSTEMS ui ui ed 4. ACCESS CONTROL SYSTEM SHALL: `" a. NOT REQUIRE KEYS, TOOLS, OR SPECIAL KNOWLEDGE TOA 1 0 0 ci N co OPERATE DOORS OR LOCKS WHEN TRAVELING IN THE o DIRECTION OF EGRESS. m a b. ALLOW NORMAL AND EMERGENCY EGRESS THROUGH FLOOR PLAN o `—�'.� DOORS AT ALL TIMES c. ALLOW DOORS REQUIRED TO HAVE FIRE RATINGS TO cis `� LATCH AT ALL TIMES