Plans (9) BU P2018-00172
I r ._____, I �J / /' € / / / r,-� 1
OD ARC,
GENERAL NOTES \ sTOR. 0ti� e
I. THESE PLANS FOR TENANT IMPROVEMENT ONLY_ 11031
- - 7 PROVIDE NEIL!CORK FLOOR / i4 . , r3
i "
�' 1 ��2, THE PROJECT DOCUMENTS ARE OF LIMITED SCOPE, Q 1 I Q , , 4111$
PREPARED BY THE ARCHITECT AT THE OWNER'S REQUEST VW I I �� -=
_ �
TO ESTABLISH MINIMUM GUIDELINES FOR CONSTRUCTION OF \ /
I I
THE PROJECT IN COMPLIANCE WITH THE APPLICABLE I I � I
I i 1, 0)
GOVERNING BUILDING CODES AND REGULATIONS. WHERE OF
MATERIALS, ASSEMBLIES, EQUIPMENT, FIXTURES, AND 1 I L —_I
SYSTEMS ARE NOT SHOWN DIAGRAMMATICALLY, IT IS THE
RESPONSIBILITY OF THE GENERAL CONTRACTOR TO SP - _
DETERMINE SPECIFIC LOCATIONS, PROVIDE SPECIFIC N/R = EXAM
MATERIALS AND DETERMINE CONSTRUCTION DETAILING, lfd4 OLS. = Imo
15� sF_ / imm
ALL IN COMPLIANCE WITH APPLICABLE BUILDING CODES, = 2 Occup_
REGULATIONS, AND INDUSTRY STANDARDS FOR MATERIALS f �/ PROVIDE NEWJ
AND METHODS OF INSTALLATION. IT IS THE CONTRACTOR'SI I / / J , CORK FLOOR 1
RESPONSIBILITY TO ASSURE THAT ALL CONSTRUCTION IS IN _ 7
- ~� _
04
COMPLIANCE W1TH APPLICABLE CODES AND REGULATIONS_ ® NEW
0 0 /
A I I
ES/EL ■ N
3, THE GENERAL CONTRACTOR 15 RESPONSIBLE FOR ALL /
N
MEANS, METHODS, TECHNIQUES AND SEQUENCES OF
CONSTRUCTION INCLUDING JOB SITE SAFETY_ THE // / __L_ WAITING
M
ARCHITECT HAS NO RESPONSIBILITY FOR THE MEANS, ( 111 O.L.F. 1-1
METHODS, TECHNIQUES OR SEQUENCES OF CONSTRUCTION EXIT lag 5F. /
INCLUDING JOB SITE SAFETY. / / / ES/EL / = 19 OCCUR. O
lr
4. THE WORK UNDER THIS CONTRACT/PROJECT IS TO INCLUDE r 1 1 / I1 I 1 1 ____,
"d
._ _
ALL THE LABOR, MATERIALS, TRANSPORTATION, EQUIPMENT, 0 I , - ,
AND SERVICES NECESSARY FOR AND REASONABLY /
INCIDENTAL TO THE COMPLETION OF ALL CONSTRUCTION O O . 0 -
WORK IN CONNECTION WITH THE DOCUMENTS. I 0
S. APPLICABLE CODES ON MATERIALS AND WORKMANSHIP
SHALL CONFORM TO THE 2014 OREGON STRUCTURAL , / OFFICE LaB
SPECIALTY CODE AND APPLICABLE STATE AND FEDERAL „ Al 11021 OLP_ = Imm 105 OLF _ loo �` N
SAFETY ORDERS. ALL REFERENCES TO CODES, Q. . / L135 5�_ / Imo0 'I-
NTENDED
AND STANDARDS SHALL MEAN AND ARE S.D = 2 OGCUP. Sm SF. / 100 to
7 1 Occup.
INTENDED TO BE THE LATEST EDITION, AMENDMENT RECEPT. O
/
AND/OR REVISION OF SUCH REFERENCE STANDARD IN 0 ® 11 01 1 OLF. = 100. 26 SF / 100 00 N
EFFECT' / = I OCCUP_ 7 0
&, EACH SUB-CONTRACTOR (OR THE GENERAL CONTRACTOR 1 � I O
WHEN HE IS PERFORMING SPECIFIC PORTIONS OF THE - — / I O
WORK) IS CONS1DERED A SPECIALIST IN HIS RESPECTIVE / . 11. la; E-+
FIELD AND SHALL, PRIOR TO PERFORMANCE OF WORK,
NOTIFY THE GENERAL CONTRACTOR AND ARCHITECT OF 0 0 0 /
ANY WORK CALLED OUT ON THE DRAWINGS IN HIS TRADE I .
___-)
THAT CANNOT BE FULLY GUARANTEED OR THAT DOES NOT i 1 , /
MEET CURRENT LOCAL BUILDING CODES. 1 H
,, / - 0TOILET RM
1. THE CONTRACTOR SHALL VERIFY AND CONFIRM ALL A �' 1Ice1 OFFICE
DIMENSIONS AND CONDITIONS SHOWN OR IMPLIED ON THE
DRAWINGS AND SPECIFICATIONS AS WELL AS THE 11061 OLP. - 100
PHYSICAL CONDITIONS OF THE SITE. NOTIFY THE / I 124 S.F. / 100
= 2 OCCUP.
ARCHITECT OF DISCREPANCIES PRIOR TO START OF WORK. I ° '
S. DIMENSIONS ARE FROM FACE OF FINISH MATERIAL_ __ F--1
H.
EXAM
S_ PATCH AND REPAIR ALL EXISTING WORK DAMAGED BY 11081 ol_F. = lolly
NEW WORK TO EXISTING CONDITION OR NEW CONDITION, 1 leSF. / lmm= IOCCUP.
WHICHEVER IS APPROPRIATE. I I PROVIDECORK EW 1 a
10_EAGN SUB-CONTRACTOR MUST REFER TO DIAGRAMMATIC - ° ° O Q, W m
PLANS AND SECTIONS AND MUST COORDINATE THEIR WORK - ES/E1. I 0 �"� I- n
WITH ALL TRADES TO AVOID CONFLICTS_ �P / E..,
EXIT z I�
cf) CP
11. DOOR HARDWARE SHALL MEET THE REQUIREMENTS OF 1 I EXAM W Z
SECTION 10043 - OREGON STRUCTURAL SPECIALTY CODE 1 I1m�l oLF. = 100 Mlel Z
AND SHALL BE EITHER A LEVER OR PANIC TYPE
REQUIRING ONLY A SINGLE MOTION TO OPEN. KEY-LOCKING = SF_/ loo M--�I l�
= 1 OCGUP. 0 r'1 _l W�
HARDWARE MAY BE USED ON THE MAIN DOOR OF B, F, M PRovl»E NEW 0 W 0
OR S OCCUPANCIES ONLY, WITH THE UNLOCKED DOOR PORK FLOORENEI 0
FREE TO SWING WITHOUT OPERATION OF ANY LATCHINGegiN
DEVICE AND A READILY VISIBLE DURABLE SIGN POSTED
Q
ON THE EGRESS SIDE IMMEDIATELY ABOVE THE DOOR I T-/------ H Q
STATING "THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING ( A / r kW. I. / I I / / / / /
-
IS OCCUPIED". THE SIGN SHALL BE IN LETTERS I" HIGH ON € 1— W N I-
in
CONTRASTING BACKGROUND. [-� .,,I (�
WITH TENANT AND , 1ST FLOOR PLAN nn H
1
12_ VERIFY KEYING REQUIREMENTSE ''4' I-�
LANDLORD. Ilir 114" = I'-0"
01
13. PROVIDE 31/211 UNFACED BATT INSULATION AT ALL NEW
WALLS.
NEW14_ PROVIDE FIRE EXTINGUISHERS AS DIRECTED BY FIRE I ES/EL CODE SUMMARY
MARSHALL AT WALK-THROUGH. I --
15. PROVIDE HVAC W/20 CFM OUTSIDE AIR PER OCCUPANT ATI I —I
I r GENERAL BUILDING DESCRIPTION: GENERAL OFFICE
i NUMBER OF STORIES: 3
OFFICE AREAS. FIRE SPRINKLERS: NONE
1&.MECHANICAL, ELECTRICAL AND PLUMBING BY SEPARATE REFLECTED CEILING PLANOCCUPANCY: B
CONSTRUCTION TYPE: 111-B
PERMITS_
1141 - I -01 TENANT SPACE SIZE; 1,425 U.SF_t
Deo/04/18
LEGEND
, , I 1 ! 7. . l
1
' _ / 20 GA. 354$11 METAL STUD BRACING TO ' EXISTING WALL TO REMAIN
ROOF STRUCTURE AT (a'-0" OC, EXISTING 2X4 FLUORESCENT
�/ ��f ALTERNATING DIRECTIONS_ FASTEN EXISTING WALL TO BE REMOVED FIXTURE TO REMAIN
�i /� BRACE TO TOP OF STUD W/(2) *S m � 0 r _
SHEET METAL SCREWS AT EACH END. �p• pa NEW WALL - 31" METAL STUDS
iiiiiIIIIII I _ii_ y( iiiiIIIIIIir CiTI � �
J ►r J 24" 0.0. 5is" GYP. BD_ EACH SIDE / EXISTING 2X4 FLUORESCENT
/
BRACING TO BE PROVIDED WHERE F J TD UNDERSIDE 01= T-BAR CEILING FIXTURE TO BE REMOVED
DISTANCE BETWEEN PERPENDICULAR
1 r
10
INTERSECTING WALLS OR HORIZONTAL __1, T._a--- - _
BRACING BETWEEN WALLS EXCEEDS tTI EXISTING 2X2 FLUORESCENT
!�'-0" O.G. o - EXISTING DOOR TO REMAIN FIXTURE TO REMAIN
CEILING
SUSPENDED E iii
NEW 2X2 FLUORESCENT
FIXTURE OR ROTATE EXISTING
• RE t
ATTACH BRACE DIRECTLY I 2X4 90°
.N TO STUD \ J j;AI r:R NEW OR RELOCATED DOOR
a ��I3'-0"x '-0" U.ON,
0 EXISTING CAN LIGHTING t0 REMAIN
716
`�$" GYP_ BD. EA. SIDE i , _"/
,r ' '-n QE MAIINGSPEAKER TO
3 " 25 GA METAL
41$0. „ ,i., __��- i is.
!/ i�`i?�61t / I I DOOR TO BE REMOVED OR
STUD AT 2 -0 O.G. //, /.� �./
/� i �� IIRELOCATEDSD EXISTING SMOKE DETECTOR
l�� 'i s��' 0
��%I 1+ I II TO REMAIN
r r�� a- Iq/,�
BOTTOM TRACK TO FINISH - ` sip/1 I NEW NEW COMBO ILLUMINATED O� 180 �
FLOOR WITH POWDER AREA OF---------[11 1 1% a•” I NEW DUPLEX ELECTRICAL ES1mP EXIT SIGN/EGRESS LIGHTING
DRIVEN ANCHORS 2'-0" D.C. WO J i�� ��•� �� W/BATTER? BACK-UP
OUTLET. BOTTOM OF COVER
I--/ , j I PLATE TO BE AT 15" A.F.F.
CONCRETE SLAB. — -- --
� _
T OFFICE COPY
1 \ I Ti 11 L ' EXISTING HVAC DIFFUSER CITY OP TIGARD
REVIE ' ` FOR CODE COMPLIANCE
Approved: ]
ri TYP. WALL DETAIL 1ST FLOOR PLAN KEY PLAN EXISTING HVAC RETURN OTC: j - A_ i_
rte'
1 I1/�"= 1'-011 Permit#: g�
NOT TO SCALE Address: C�
7�'3S S 1,.t �4�r��1 t_�n
Suite#; 4-By: Date: Fi- c_1 O� i