Loading...
Plans (128) F PS2019-00026 n Sk 0 C� , k_C \ , R-(\ .# J Lx N c ii, LN 3 .��i 0 CON. o�o Johnson - � o o fro O �- !:.:, ontro s o�,,,,, � V 2O rn� Woao�DRAWING INDEX LEGENDS APPLICABLE CODES & STANDARDS JOHNSON CONTROLS CONTACTS I- Y5 JURISDICTIONS WITHIN THE STATE MAY HAVE AMENDMENTS TO THE STATE ADOPTED CODE.CHECK WITH THE Sales Representative Drawings Prepared By LOCAL JURISDICTION AUTHORITY FOR MORE DETAILS. FIRE ALARM SY M B 0 L LEGEND Oregon Structural Specialty Code,2014 Edition BRYAN ADAMS MARIA GERRONE BRYANADAMS@1CI.COM MARTA.GERRONE@JCI.COM PHONE:503 683 9000 PHONE:503-683-9000 Oregon Fire Code,2014 Edition NICET LEVEL IV #126987 -"I'llimil** Sheet List Table SYMBOL 1 DESCRIPTION BRAND 1 MODEL BOX WIRE RECEIVED Sheet# Sheet Title I CODE TYPE Oregon Mechanical Specialty Code,2014 Edition FEB 2 PANELS&ANNUNCIATORS Scheduling6 IFA-001 COVER SHEET Oregon Electrical Specialty Code,2017 Edition FAITH KASKE 201 .., NAC4 14009IDNET NAC EXTENDER PANEL BEIGE,120 VAC ( SIMPLEX I 4009-9201 I MFG I FAITH.KASKE@1CI.COM Gin'GF TIGARD IFA-101 DEVICE PLACEMENT PLAN-5TH FLOORNational Fire Alarm Code(NFPA 72),2013 Edition PHONE:503-683-9000 BUILDING DIVISION IFA 501 PANEL DETAIL AND CALCULATIONS I INITIATING DEVICES IFA-701 WIRING TYPICALS I a MANUAL PULL STATION SIMPLEX 4099-9001 4G M 1E O ADDRESSABLE PHOTOELECTRIC SMOKE SENSOR WITH SIMPLEX 4098-9714 HEAD 4K M STANDARD BASE 4098-9792 BASE 1C MODULES&RELAYS 1RELAY IAM I SIMPLEX I 4090-9002 1 4H I M NOTIFICATION APPLIANCES OCCUPANCY TYPE(S): SPRINKLER PROTECTION: # STROBE,WALL MOUNT,RED,FIRE,CLEAR LENS SIMPLEX 4906-9101 1A V 4A B Business Group BUILDING IS FULLY SPRINKLED # STROBE,CEILING MOUNT,RED,FIRE,CLEAR LENS SIMPLEX 4906-9102 1E V HB , , # MRE,CLEARLENELA S HORN/STROBE,WALL MOUNT,RED, SIMPLEX 4906-9127 4A SCOPE 0 F WORK PROJECT DIRECTORY # MULTI CANDELA HORN/STROBE,CEILING MOUNT,RED, SIMPLEX 4906-9128 4A V LTJ FIRE,CLEAR LENS 1B MODIFY EXISTING FIRE ALARM SYSTEM: PROVIDE NEW DEVICES AS SHOWN ON DRAWINGS. Site Johnson Controls District-448 MISCELLANEOUS DEVICES ALL NEW WIRING TO BE CLASS B. LINCOLN 3 . 4081-9008I I 10220 SW GREENBURG RD 6305 SW ROSEWOOD ST,SUITE A 10K END-OF-LINE RESISTOR 10K(EOL) SIMPLEX THE EXISTING FIRE ALARM SYSTEM SHALL NOT BE DISCONNECTED OR TAKEN OUT OF SERVICE WITHOUT WRITTEN PERMISSION FROM THE OWNER. IT IS THE TIGARD,OR 97223 LAKE ,OR 97035 PHONE:E: 503-503-683-9000 BACKBOX CODES CONTRACTOR'S RESPONSIBILITY TO COORDINATE WITH THE OWNER THE TIMING OF ANY EXISTING FIRE ALARM SYSTEM DEMOLITION WORK. FAX: 503-675-6521 CODE BOX SPECIFICATIONS CODE BOX SPECIFICATIONS SERVICE:503-683-9001 4A 4"SQ.BOX 11/2"DEEP 1E SINGLE GANG BOX 2 1/2"DEEP 4B 4"SQ.BOX 11/2"DEEP W/COVER 1F SINGLE GANG BOX 2 1/2"DEEP W/COVER Owner Installer 4C 4"SQ.BOX 11/2"DEEP W/11/2"EXT.RING 1G SINGLE GANG BOX 2 3/4°DEEP 4D 4"SQ.BOX 21/8"DEEP 1H SINGLE GANG BOX 31/2"DEEP DESIGN STATEMENT SHORENSTEIN REALTY SERVICES POINT MONITOR CORPORATION 4E 4"SQ.BOX 21/8"DEEP W/COVER 2A DOUBLE GANG BOX 2"DEEP 110220 SW OR GREENBURG EN URG RD 5863 LAK LAKEVIEW EG OR 97035 E 100 4F 4"SQ.BOX 21/8"DEEP W/11/2"EXT.RING 2B TWO GANG BOX 2 1/2"DEEP DESIGN IS FOR NOTIFICATION OF THE OUTLINED AREA OF WORK. 4G 4"SQ.BOX 2 1/8"DEEP W/SINGLE GANG COVER 2C TWO GANG BOX 2 3/4"DEEP 4H 4"SQ.BOX 21/8"DEEP W/TWO GANG COVER 5A 5 GANG BOX 21/2"DEEP 4J 4"SQ.BOX 21/2"DEEP 6A 6 SINGLE GANG BOXES 31/2"DEEP 4K 4"OCT.BOX 11/2"DEEP 6B 6 GANG BOX 4L 4"OCT.BOX 11/2"DEEP W/11/2"EXT.RING 6C 6 GANG BOX 21/2"DEEP 4M 4 11/16"SQ.BOX 21/8"DEEP 6D 6 GANG BOX 31/2"DEEP 4N 4 11/16"SQ.BOX 11/2"DEEP W/11/2"EXT.RING FBO FURNISHED BY OTHERS 4P 411/16"SQ.BOX 21/8"DEEP W/11/2"EXT.RING MFG SUPPLIED BY MANUFACTURER 4Q 4"SQ.BOX 11/2"DEEP W/4098-9832 ADAPTER MDW MOUNTS TO DUCTWORK 4R 4"SQ.BOX 1 1/2"DEEP W/RACO 787 OR EQUIV. MBD MOUNTS IN BOX BEHIND DETECTOR 4S 4"SQ.BOX 11/2"DEEP W/4098-9863 ADAPTER WM WALL MOUNT ABBREVIATIONS LEGEND DEVICE TAG LEGEND lA SINGLE GANG BOX 11/2"DEEP DT DESK TOP MOUNT 1B SINGLE GANG BOX 2"DEEP DS REFER TO PRODUCT DATASHEET 1C SINGLE GANG BOX 21/8"DEEP NR NO BACKBOX REQUIRED AC = ABOVE CEILING NEC = NATIONAL ELECTRIC CODE AFF = ABOVE FINISHED FLOOR NFPA = NATIONAL FIRE PROTECTION ASSOCIATION PANEL DESIGNATOR 1D SINGLE GANG BOX 21/8"DEEP W/COVER TRM 3.5"WIDE SNAP TRACK W/MOUNTING SCREWS AH1 = AUTHORITY HAVING JURISDICTION NIC = NOT IN CONTRACT • FA:=FACP(NON-NETWORK) FOR ADDITIONAL BACK BOX OPTIONS,REFER TO THE XX-700 SERIES DRAWINGS OR PRODUCT DATA SHEETS AND ALM = ALARM NPU = NETWORK PROCESSING UNIT • #:=NODE NUMBER INSTALLATION INSTRUCTIONS. ANN= ANNUNCIATOR NTS = NOT TO SCALE • T#:=TRANSPONDER NUMBER BMS=BUILDING MANAGEMENT SYSTEM PAP= PRE-ACTION PANEL • #:T#=NODE:TRANSPONDER NUMBER TA c =CEILING MOUNTED RC = EXISTING TO REMOVE AND COVER • N#:=NAC EXTENDER NUMBER CD=CANDELA RATING RD = EXISTING DEVICE TO BE RELOCATED DESIGNATOR CIRCUIT DET =DETECTOR RL = RELOCATED DEVICE CC A#:#T =EPS'NUMBERIDNAC�CHANNEL NUMBER LA DGP = DATA GATHERING PANEL RR = REMOVE EXISTING&REPLACE WITH NEW • E =EXISTING TO REMAIN SCC= STATUS COMMAND CENTER • D#=DOOR HOLDER CIRCUIT NUMBER LL' EOL = END OF LINE SLC = SIGNALING LINE CIRCUIT • F#=FIRE PHONE CIRCUIT H EPO = EMERGENCY POWER OFF SMK = SMOKE • H#=AUDIBLE(HORN)CIRCUIT NUMBER FAA =FIRE ALARM ANNUNCIATOR SUPV = SUPERVISORY • M#=IDNET LOOP NUMBER ily FACP =FIRE ALARM CONTROL PANEL TAC =TRUEALERT ADDRESSABLE CONTROLLER • P#=POWER CIRCUIT NUMBER c FATC =FIRE ALARM TERMINAL CABINET TRBL=TROUBLE • S#=SPEAKER CIRCUIT NUMBER FBO =FURNISHED BY OTHERS TS=TAMPER SWITCH • V#=VISUAL CIRCUIT NUMBERtn o FCC = FIRE COMMAND CENTER TYP = TYPICAL • Z#=ZONE NUMBER 0 9 FSD = FIRE SMOKE DAMPER UON=UNLESS OTHERWISE NOTED1 CC LL FTR = FIRE ALARM TRANSPONDER VCC= VOICE COMMAND CENTER DEVICE NUMBER 0 H= HIGH HUMIDITY VT =VALVE TAMPER BRANCH/ISOLATED LOOP DESIGNATOR: W Ce HT = HEIGHT W = WATTAGE • (L#)=IDNET ISOLATED LOOP NUMBER N HVAC = HEATING VENTILATION&AIR CONDITIONING W/= WITH • (#)=IDNAC BRANCH NUMBER W m N IMS = INFORMATION MANAGEMENT SYSTEM W/O= WITHOUT r�r� ,- m • (E#:#)1.EPS=ENHANCED POWER SUPPLY M Q W N cn OFFICE COPY FIRE ALARM WIRE LIST ACCEPTABLE CABLE TYPES MIN = MINIMUM WG= WIRE GUARD Z MAX = MAXIMUM WF = WATERFLOW = N N NUMBER o N/A = NOT APPLICABLE WP = WEATHERPROOF 1:T2:A2:1-1(E1:1) 2.IDNAC=ADDRESSABLE NOTIFICATION CIRCUIT Z W m I CIRCUIT DESCRIPTION CONSTRUCTION GAUGE CIRCUIT PROPERTIES a a = 15 NAC=NOTIFICATION APPLIANCE CIRCUIT XP =EXPLOSION PROOF 3.EPR=ENHANCED POWER REPEATER u i 0 Ce g 0 v NDU= NETWORK DISPLAY UNIT 0 -' M L'I'TY OP'TIGARD ^' I V I VISUAL SIGNAL 2 COND.SOLID 14 AWG X X X ....1 J Q REVIEWED FOR CODE COMPI.IANCS IA SYSTEM SEQUENCE OF OPERATIONS Y I CONCUR SIZE MAX CONDUCTOR AREA I CONCUR SIZE MAX CONDUCTOR AREA NOTESCe Approve:; 1/2" 0.12 SQ INCH* 1-1/4" 0.60 SQ INCH* *40%FILL PER N.E.C. Z Ce 0 N a OTO 1 . 3/4" 0.21 SQ INCH* 1-1/2" 0.82 SQ INCH* SUBSCRIPT"u":UNSHIELDED CABLES MIXED WITH • Z N (' i1" 0.34 SQ INCH* 2" 1.34 SQ INCH* SHIELDED CABLES OF SAME CIRCUIT DESIGNATION. moilI' 0 rcitnit r _Q **OUTDOOR AERIAL CABLE REQUIRES MESSENGER STP=SHIELDED TWISTED PAIR,UTP=UNSHIELDED TWISTED PAIR 1.. . J Addtes 0 ?irk - 5i�.! .4ef�t �! le--6 ITEMS SUCH AS CAPACITANCE BETWEEN CONDUCTORS AND WIRE GAUGE CAN BE CRUCIAL TO THE CIRCUIT DESIGN OF THIS SYSTEM 175 a INSTALLATION.THE INSTALLING CONTRACTOR IS RESPONSIBLE FOR SELECTING AND INSTALLING CABLE MANUFACTURER AND MODEL N � = THAT MEETS OR EXCEEDS THE ABOVE REQUIREMENTS.RECOMMENDED CABLE MANUFACTURERS AND MODEL NUMBERS ARE AVAILABLE 1 1 CONTROL UNIT ANNUNCIATION 1 NOTIFICATION REQUIRED FIRE SAFETY CONTROL SUPPLEMENTARY ' - _ B /r1 ,Date 7 UPON REQUEST. O .3 Q O 5 V s - S . \\ O�C'P POR' 4 ' �C3 <3"- 000 :; ce Q �, 5 4- 4"-&\ O� 'Q' QQ' <0 J �0 C,Q '� Q, Q,' J -1 �V �� O 5 J � 5 k. 0� 5�C'�c�\C'�\00�COQ 05�c'G� GJP JP OF 05 v4- ,`O \0 00) G ,- � <3- <;S J0'* \0 P�QG 3 \, CD 4.' .F' mac' <c.0 S' P F' P\r-�-�JQ �JQ .�O'<- \'' �P�`` C G,�N.- 4-oS� �`o \, 00° F`� �o� ����,�, 5 �O&\0`C�OC�\0\C�O�\0\C O. PJO�O\0 \�.\ ��`'���JO:,,, e�� P �\ i.-s,_ .)- O,*, 00- cc CJ P G P G P PQ P P 4' 5 ‹c O Q. .\ 5 JO O* JO O� J0 Q� �\' •• Q�Q Y-OJQ `Q`O PC' �C,J � Q ,P 0 �J P P P P P P P �P P O J C,� P �c �0 F ON- . G C, G G G G C, G �5 0 S' , , P N- } SYSTEM INPUTS A BCDE F GH I JK L MNOPQR S T UV W X Y Z AA AB AC AD AE AF AG AH REMARKS GENERAL NOTES RISER DIAGRAM I 1 SMOKE SENSOR/DETECTOR • • • • • • • • • • • 1 N I 2 MANUAL PULL STATION • • • • • • • • 2 1. THESE DRAWINGS DEPICT GENERAL LOCATIONS OF LIFE SAFETY EQUIPMENT&FIELD DEVICES.EXACT ROUTING OF CONDUITS IS TO BE DETERMINED IN 13 DUCT SENSOR/DETECTOR • • • • • • • • • 3 THE FIELD BY THE INSTALLING CONTRACTOR TO SUIT CONDITIONS. ALL CHANGES SHALL BE CLEARLY INDICATED ON THE RECORD DRAWINGS. RISER NOTES: 14 MAIN FLR. ELEV. LOBBY SMOKE DETECTOR 4 Z 2. SHOULD ANY CONDITIONS EXIST THAT DIFFER FROM WHAT IS INDICATED ON THESE DRAWINGS WHICH CAUSE MAJOR DEVIATIONS IN THE WORK 15 ELEVATOR LOBBY SMOKE DETECTORS (EXC. MAIN FLR.) • • • • • • • • • • • • • 5 E SHOWN,THE CONTRACTOR SHALL CONTACT JOHNSON CONTROLS IN A TIMELY MANNER SO AS NOT TO IMPAIR THE CONSTRUCTION SCHEDULE. i. RISER IS A DIAGRAMMATICAL REPRESENTATION OF THE SYSTEM 16 ELEVATOR MECH. ROOM SMOKE DETECTOR • • • • • • • • • • • 6 E3. CONTRACTOR IS RESPONSIBLE FOR MAKING AND OBTAINING APPROVAL FOR ALL NECESSARY ADJUSTMENTS IN CIRCUITING AS REQUIRED TO ARCHITECTURE IN BUILDING CROSS SECTION.IT IS NOT INTENDED TO 1 7 WATERFLOW SWITCH •• •• •• •• •• •• •• •• •• •• •• 7 W ACCOMMODATE THE RELOCATION OF EQUIPMENT AND/OR DEVICES WHICH ARE AFFECTED BY ANY AUTHORIZED CHANGE.ALL CHANGES SHALL BE REPRESENT ACTUAL WIRE RUNS,PANEL CONFIGURATIONS OR 18 TAMPER SWITCH • • • • • 8 a CLEARLY INDICATED ON THE RECORD DRAWINGS. PENETRATIONS.REFER TO FLOOR PLANS AND PANEL DETAILS FOR • • • 19 POST INDICATOR VALVE SWITCH 9 ae 4. A STAMPED SET OF APPROVED FIRE ALARM DRAWINGS SHALL BE AT THE JOB SITE AND SHALL BE USED FOR INSTALLATION. CIRCUIT ROUTING AND CONFIGURATION INFORMATION. 10 FIRE ALARM AC POWER FAILURE • • • • • • 10 v 5. THE POWER CIRCUIT TO THE FACP AND TO THE FIRE ALARM POWER SUPPLIES SHALL BE ON A DEDICATED 120V,20A BRANCH CIRCUIT BREAKER,AND 2. ALL WIRING SHALL COMPLY WITH APPLICABLE ELECTRICAL CODES. 11 FIRE ALARM SYSTEM LOW BATTERY • • • • 11 in SHALL HAVE A RED MARKING,LOCK-ON PROVISION AND SHALL BE IDENTIFIED AS"FIRE ALARM CIRCUIT CONTROL" THE LOCATION OF THE CIRCUIT REFER TO'APPLICABLE CODES&STANDARDS'ON SHEET FA 001 FOR 12 OPEN CIRCUIT • 12 a DISCONNECT MEANS(CIRCUIT BREAKER)SHALL BE PERMANENTLY IDENTIFIED AT THE FIRE ALARM CONTROL UNIT. SPECIFIC CODE REFERENCES. 13 GROUND FAULT 13 3. DEVICES ARE TYPICAL SEE FLOOR PLAN FOR QUANTITY&LOCATIONS. • • • • 6. UPDATE THE AS-BUILT DRAWING SET DAILY WITH JOB PROGRESS. RETURN THE AS-BUILT DRAWING SET TO JOHNSON CONTROLS NO LATER THAN 7 14 NOTIFICATION APPLIANCE CIRCUIT - CLASS B/STYLE Y: 14 4. EXISTING DEVICES ARE SHOWN SHADED FOR REFERENCE. 15 WIRE-TO-WIRE SHORT • • • • 15 i DAYS AFTER FINAL TEST. a v. 7. THE CONTRACTOR WILL MAINTAIN ALL AREAS OF THE BUILDING IN A NEAT AND WORKMANLIKE MANNER. 16 ROOF DRAIN • • • • • 16 0 c M 8. DO NOT APPLY POWER EXCEPT IN THE PRESENCE OF A FACTORY TRAINED JOHNSON CONTROLS TECHNICAL REPRESENTATIVE. 17 17 0 9. ANY SMOKE DETECTOR HEAD INSTALLED BEFORE THE BUILDING IS CLEANED AND ACCEPTED SHALL BE COVERED TO PROTECT FROM DUST. ANY FALSE 18 18 N ce o ALARMS DUE TO DIRT CONTAMINATED HEADS SHALL BE THE RESPONSIBILITY OF THE FIRE ALARM INSTALLER. 19 19 a 10. THE FIRE ALARM INSTALLER WILL MAINTAIN THE FIRE RESISTANCE INTEGRITY OF ALL WALL,CEILING,AND ROOF ASSEMBLIES ANY TIME THAT WORK IS 20 20 N NOT ACTIVELY BEING PERFORMED. o V� 21 21 0 11. INSTALLATION OF DEVICES SHALL BE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. POWER LIMITED AND NON-POWER LIMITED FIELD (N4:V1) Vl 122 22 z l0K 123 23 DRAWN BY: R.HERMANT WIRING MUST BE INSTALLED WfTHIN THE FACP ENCLOSURE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND APPLICABLE ELECTRICAL C _ _ 124 24 CODES.REFER TO'APPLICABLE CODES&STANDARDS'FOR SPECIFIC CODE REFERENCES. w V� V2 NAC4 25 25 CHECKED BY: M.GERRONE 12. ALL WIRING SHALL BE INSTALLED ACCORDING TO APPLICABLE ELECTRICAL CODES. (N4:V3)137 Yom- 3 13. FIRE ALARM CIRCUITS SHALL BE IDENTIFIED IN ACCORDANCE WITH APPLICABLE ELECTRICAL CODES. MARK ALL FIRE ALARM WIRES IN ACCORDANCE 4009 26 2� ISSUE DATE: 2/19/19 WITH APPLICABLE ELECTRICAL CODE SECTIONS FOR POWER LIMITED AND NON-POWER LIMITED WIRE. y ` �a V JOB#: (N41))���`1 1� �I V3 28 28 14 FIRE ALARM CABLE INSTALLED IN DUCTS,PLENUM,AND OTHER SPACES USED FOR ENVIRONMENTAL AIR SHALL BE TYPE FPLP. PROJECT#: 448:611201301 29 29 15. FIRE ALARM CABLE INSTALLED IN THE VERTICAL RUNS AND PENETRATING MORE THAN ONE FLOOR OR CABLES INSTALLED IN VERTICAL RUNS IN PHONE CLOSET 30 30 JOHNSON CONTROLS©2019 SHAFTS SHALL BE TYPE FPLR. (N4:V4)a��Js_ff V4 31 31 SYSTEM: • 16. FIRE ALARM CABLE INSTALLED IN UNDERGROUND CONDUIT OR OTHER WET LOCATIONS SHALL BE UL LISTED FOR WET LOCATIONS. 10K •••*•'LL�.JJ �� ABCDEF GH I JK L MNOPQRS T U V W X Y Z AA AB AC AD AE AF AG AH 17. FIRE ALARM CIRCUITS EXTENDING BEYOND ONE BUILDING AND RUN OUTDOORS SHALL BE INSTALLED IN ACCORDANCE APPLICABLE ELECTRICAL FIRE ALARM SYSTEM CODES,WHERE APPLICABLE. 18. ALL WIRING,INCLUDING SHIELDS MUST BE DRY AND FREE OF SHORTS AND GROUNDS. 120VAC SHEET: 19. ALL SHIELDED WIRE MUST HAVE SHIELD CONTINUITY AT FULL LENGTH OF THE WIRE. "*.. .2-47 20. ONLY SYSTEM WIRING CAN BE RUN IN THE SAME CONDUIT. 5TH FLOOR 21. 120VAC IS NOT PERMITTED IN THE SAME CONDUIT WITH LOW VOLTAGE WIRING. 22. MAINTAIN MAXIMUM CONDUIT FILL RATIO AS PER APPLICABLE ELECTRICAL CODES REQUIREMENTS. � j� COVER SHEET L 23. EXISTING CONDUITS MAY BE USED BY THE INSTALLATION CONTRACTOR AS DEEMED NECESSARY;HOWEVER,ANY EXISTING CONDUIT WILL BE USED '�` ONLY IF CONDUITS MEET CURRENT STANDARDS AND CODES.JOHNSON CONTROLS MAKES NO STATEMENTS WRITTEN OR VERBAL AS TO THE L-41-1 ID N CONDITION OF EXISTING CONDUITS. in IMPORTANT NOTICE TO USER:This information may not be sold or transferred to any third party,used on other projects or additions to the a project for which it was prepared,or used for completion of this project by any third party. Johnson Controls disclaims all liability for the use or FA-o0 1 I---,, reuse of altered files by the user or any third party and such use will be a user's sole risk. User shall,to the fullest extent permitted by law,defend, x indemnify,and hold Johnson Controls harmless from any and all claims for loss,damage or injury arising directly or indirectly from any such o unauthorized use. J . . ..is_ . - ©Johnson Controls 2019.All rights reserved.Reuse,copying,modification or alteration of the drawings and other information contained herein is strictly prohibited. GENERAL NOTES: 1. ALL CEILINGS ARE ASSUMED TO BE 10'A.F.F.,SMOOTH CONSTRUCTION UNLESS NOTED OTHERWISE. �`�-40 2. EXISTING DEVICES SHOWN SHADED FOR REFERENCE. o .."11V m^ 00 M P+9 in ,..,-,.-r1 Z C O .X aau- � cV) C ~M MC 0 I-o� o co !Loro `. Owo 11 a v,0v G koJ(n r 0 I i - - T_E L 1 0 N4:V3-7 • ! 4 (N4:V3) 1s BREAK 10K/ •• CONF. N4:V3-6 • 15 H ----- CLOSET I \ I TELCO N4:V3-5 V it_ ii I \ VACANT j75 I" N4:V3-4 INTERVIEW V •• SUITE BULLPEN l; 75 SUITE V N4:• -I N4:V4-2 II 535 •• 15 CONFERENCE 571 RECEPTION 411 15 ql 508 N4:V3-2 L M1-179 N4:V3-1 V INTERVIEW AREA OF WORK h / n ... • u1 15 •• li V 0 N4:V4-1 I NORTH �' FE N4:V1 2 M1 183 D V ---Y---! CORRIDOR M1-182/7\ N o 15 •• V • S TO NAC4 M1-184 15 - \ \-:-31/-2-1`-1 C V OFFICE IFI •• V i PHONE CLOSET �/ H I� I 510 I i \ OS Ml 180 ^ V 5 • NAC4 M1181 r N4:V13 --H �a I EAST V \ \ \ \ \ CORRIDOR '�- OFFICE OPEN ii - 507 OFFICE 1 509 OFFICE 1 '- I 511 I _ r\\= �� N4:V1 12T-°) TO NAC4 \ WOMEN'S MRR\ Q STAIRS #1 15 V1 III •• V 7 u STAIRS #2 mi 15 O V N4 8• 5 • v N4:V1 95 1 OFFICE;i 506 l' N4:V1-4 M1-185 •. • �V _ • 5 N4:V2 i SUITE ,,n 'i ELEVATOR • 1! 0 • 1 I " 501 0wI LOBBY _ N4 w1-7 N4:V1 = i Emm\ 11 STORAGE SE513ER, 1 �\ �, di `i 1 J N4:V1-11 tn V per. 15 0,'' .--i III� •• 15 A L� I 0 Ce �I N4:V4-3T. M1-1871 F ILz , V •. ENTRY 15 • OM1186 : V ) 75 SOUTH : M1-1880 CC en , I 501 I N4:V1-5 C CORRIDOR N 75 _ N4:V1-6 V �' m M us esi N4:V4 4 li , r � ce �; RECEPTION �� I L OPEN 502 LL1 en, V CC 0 OFFICE (N4:V2) 15 SUITE Z 505 ! II 10K ci- -WW N4:V2�n8''` V - N ,; ' 551 N4:V2 2 Z_ O N Q Li ` o 75 //� \ '..� J 1-4 I— . , aiv J ADW • o BREAK 15 50371' N4:V2-5 V E. `l (N4:V4) \I - -V I V 3 10K N4:V4-5 / 3 15 D14 o : : LT Cc N4:V4 7 V 1 N4:V2 7 15 N4:V2 6 / o ' 15 N 110 V N4:V2-3 w • 30 y N4:V2 4 7: ,f/% > V • 30 3� 30 V N4:V4-6 OFFICE I I504I , / a W 0 0 0 II , , I � 0r / w a o E. PLAN H NORTH c DEVICE PLACEMENT PLAN — 5TH FLOOR U D SCALE: i/8"=1'0" ����� .Q,, NC 0 4 8 16 (IN FEET) • W 0 a ct CI m O Nd ccm vi Q rn 0 N 0'. '-4 N 0 W z DRAWN BY: R.HERMANT F CHECKED BY: M.GERRONE ISSUE DATE: 2/19/19 JOB#: PROJECT#: 448:611201301 JOHNSON CONTROLS©2019 SYSTEM: FIRE ALARM SYSTEM SHEET: DEVICE PLACEMENT PLAN - 5TH FLOOR N In `--u W L V a` N FA-101 X m J i ©Johnson Controls 2019.All rights reserved.Reuse,copying,modification or alteration of the drawings and other information contained herein is strictly prohibited. GENERAL NOTES: 1. EXISTING DEVICES SHOWN SHADED FOR REFERENCE. 0r'sl .111111111.11111 4 09 1/49u1 co N- M M IA `p O CaZ C OO oX O „�., C C HM O ENC U `-'ce 0.' Ol IG ;LIQ Nook LAAou IAA OYCC c �gN NAC4-VOLTAGE DROP SUMMARY 4009 NAC4 - 5TH FLOOR, PHONE CLOSET Plan Circuit Description Load %Drop Standby Total Alarm Total N4:V1 FIFTH FLOOR NOTIFICATION SIG1 1.O11A 6.51% Module QtY Description Current Standby Current Alarm N4:V2 FIFTH FLOOR SUITE 551 NOTIFICATION SIG2 0.915A 5.50% N4:V3 FIFTH FLOOR SUITE 535 NOTIFICATION SIG3 0.596A 1.99% Panel Equipment N4:V4 FIFTH FLOOR SUITE 571 NOTIFICATION SIG4 0.847A 4.72% 4009-9201 I 1 14009 IDNET NAC EXTENDER,120 VAC I 0.0850 I 0.0850 0.1850 0.1850 Panel Totals 0.0850 0.1850 Notification Devices 4906-9101 16 V/0 M-C NON-ADDRESS,RED,WALL 15 0.0000 0.0000 0.0600 0.9600 4906-9101 2 V/0 M-C NON-ADDRESS,RED,WALL 30 0.0000 0.0000 0.0940 0.1880 4906-9102 4 V/0 M-C NON-ADDRESS,RED CEIL 15 0.0000 0.0000 0.0750 0.3000 N4:V1 Distributed Load Voltage Drop 4906-9127 1 A/V M-C NON-ADDRESS,RED,WALL 110 0.0000 0.0000 0.2850 0.2850 Allowable%Drop:I 16% 2x Wire Resistance 0.0061 4906-9127 4 A/V M-C NON-ADDRESS,RED,WALL 15 0.0000 0.0000 0.0750 0.3000 Wire Gauge:I 14ga Min.Device Voltage: 16vdc 4906-9127 1 A/V M-C NON-ADDRESS,RED,WALL 30 0.0000 0.0000 0.1160 0.1160 • Starting Voltage:I 19vdc %Voltage Drop 6.51% 4906-9127 4 A/V M-C NON-ADDRESS,RED,WALL 75 0.0000 0.0000 0.2210 0.8840 4906-9128 1 A/V M-C NON-ADDRESS,RED CEIL 15 0.0000 0.0000 0.0860 0.0860 Normal Operation 4906-9128 1 A/V M-C NON-ADDRESS,RED CEIL 75 0.0000 0.0000 0.2500 0.2500 Distance Device Voltage Voltage At Peri heral Totals 0.0000 3.3690 Device# PID Candela (feet) Current Drop Device A dress Totals 0 Addresses 0.0000 0.0000 N4:V1-1 4906-9128 15cd 35 0.08600 0.217 18.78 Total Standby 0.0850 Total Alarm 33540 N4:V1-2 4906-9102 15cd 56 0.07500 0.535 18.46 N4:V1-3 4906-9102 15cd 20 0.07500 0.640 18.36 Standby Alarm N4:V1-4 4906-9127 15cd 31 0.07500 0.787 18.21 N4:V1-5 4906-9102 15cd 29 0.07500 0.912 18.09 Battery Set#1 (Cabinet/Charger#1) Current Current N4:V1-6 4906-9128 75cd 41 0.25000 1.069 17.93 0.0850 <--Total > 3.5540 N4:V1-7 4906-9101 15cd 26 0.06000 1.129 17.87 StandbyTime= StandbyAh • N4:V1-8 4906-9101 15cd 10 0.06000 1.148 17.85 24 Hrs 2.0400 N4:V1-9 4906-9101 15cd 18 0.06000 1.177 17.82 Alarm Time= 5 Mins. 0.2962 Alarm Ah Standby+Alarm= 2.3362 N4:V1-10 4906-9101 15cd 12 0.06000 1.191 17.81 Additional Spare Capacity N4:V1-11 4906-9101 15cd 29 0.06000 1.215 17.79 P P tY= 0% + 0.0000 N4:V1-12 4906-9102 15cd 47 0.07500 1.237 17.76 2.3362 Battery Discharge Factor per NFPA 2010= 20% + 0.4672 Totals: 354 Ft 1.011A Minimum BatteryRequired q 2081-9272 6.2 AH 2.8034 Battery Supplied 2081-9272 6.2 AH I N4:V2 Distributed Load Voltage Drop Allowable%Drop:I 16% 2x Wire Resistance: 0.0061 Wire Gauge:I 14ga Min.Device Voltage: 16vdc Starting Voltage:I 19vdc %Voltage Drop 5.50% Normal Operation Distance Device Voltage Voltage At Device# PID Candela (feet) Current Drop Device I N4:V2-1 4906-9101 15cd 54 0.06000 0.303 18.70 111 I N4:V2-2 4906-9127 75cd 20 0.22100 0.408 18.59 I N4:V2-3 4906-9101 15cd 20 0.06000 0.486 18.51 IF OPTIONAL SHIELDS ARE USED FOR IDNet WIRING. 1.11 N4:V2-4 4906-9127 15cd 87 0.07500 0.793 18.21 FOLLOW THESE PRECAUTIONS. N4:V2-5 4906-9101 15cd 20 0.06000 0.854 18.15 111■ ■ 1. IF IDNet WIRING CONTINUES ON TO ANOTHER DEVICE,TAPE ■.ii N4:V2-6 4906-9101 30cd 20 0.09400 0.908 18.09 SHIELDS TOGETHER.DO NOT TERMINATE SHIELD AT 4009 M� FROM PREVIOUS IDNet DEVICES Elm N4:V2-7 4906-9127 110cd 60 0.28500 1.035 17.96 IDNet ' OR HOST IDNet CONTROL PANEL •1 N4:V2-8 4906-9101 15cd 29 0.06000 1.046 17.95 2. IF IDNet WIRING TERMINATES AT 4009,TAPE SHIELD.DO NOT M� TO ADDITIONAL IDNet DEVICES Totals: 310 Ft 0.915A TERMINATE SHIELD AT 4009 IDNet. ' ' OR RETURN TOHOST IDNet CONTROL PANEL VI A IDNet CONTROLLER ADDRESS: M1-181 Q 8 N4:V4 Z 1 OC 0 a N4:V3 Distributed Load Voltage Drop N4:V3 t V-a o N4:V2 2 v-� V CC Allowable%Drop: 16% 2x Wire Resistance: 0.0061 N4:V1 2 V-" 7-1 M m M En Wire Gauge: 14ga Min.Device Voltage: 16vdc Vim' O Z N a Starting Voltage: 19vdc %Voltage Drop 1.99% Z LJJ N g Normal Operation I ( f I I 1 W MLI °C Voltage Voltage At - O 0 Distance Device 9 9 � -- O Device# PID Candela (feet) Current Drop Device - �/ N4:V3-1 4906-9127 15cd 40 0.07500 0.146 18.85 I 5 m �m4cWi U E3 I Cd � LL/, 0 a N4:V3-2 4906-9101 15cd 29 0.06000 0.239 18.76 ''©©' ©° '! o vl vl a m a m �1 Iii Z N (� N4:V3-3 4906-9101 15cd 11 0.06000 0.270 18.73 RK1 'NK2 NAC3 v IDNET H J pi �SW1 _SW2 a N4:V3-4 4906-9127 75cd 25 0.22100 0.332 18.67 0 J N4:V3-5 4906-9101 15cd 25 0.06000 0.359 18.64II �) E a N4:V3-6 4906-9101 15cd 16 0.06000 0.371 18.63 a D ,, d F0pV N4:V3-7 4906-9101 15cd 19 0.06000 0.378 18.62 © El El 11 �® © Totals: 165 Ft 0.596A ist: 0--L7 0-' Arta - AUX POWER o o O H 0 o + O 0 Io roSOU OO/ o ROS our INPUTIHARDWIRE _5 Rna 1 0 o O RET OUT VISIBLE 0 0 n 0 r N4:V4 Distributed Load Voltage Drop �N I 0 0 RREETT OUT AUDIBLE BATTERY O Allowable%Drop: 4009-9201 IDNet NAC EXTENDER _ _ab_ ASSYADDAsn A0000 0 (1 P 16% 2x Wire Resistance: 0.0061 0565-E1BLE A0C0AC SYSTEM © `MJ Wire Gauge: 19vdc Min.Device Voge Drop 4672% -= O 0 /i// //X//���. Starting Voltage: 1972% %Voltage Drop 4.72% • INTERNAL BATTERY `�HARNESS 733-991 / HARNESS 733-945 / UND r w Normal Operation tCd ( J�1 I i /' NEGRUTRAL _CONNECT TO 120VAC 60HZ INPUT 3A MAX. Distance Device Voltage Voltage At + �� HOT 12W STRIPT / P o O Device# PID Candela (feet) Current Drop Device Q N4:V4-1 4906-9127 30cd 73 0.11600 0.380 18.62 PART I 6.2 Ah BATTERY 6.2 Ah BATTERY / I N4:V4-2 4906-9127 75cd 30 0.22100 0.514 18.49 2081-9272 2081-9272 t- zc N4:V4-3 4906-9101 15cd 76 0.06000 0.752 18.25 / a N4:V4-4 4906-9127 75cd 21 0.22100 0.810 18.19 /, N4:V4-5 4906-9101 15cd 42 0.06000 0.869 18.13 1-<> v N4:V4-6 4906-9101 30cd 19 0.09400 0.889 18.11 _ _ % o N4:V4-7 4906-9127 15cd 16 0.07500 0.896 18.10 / s Totals: 277 Ft 0.847A CONNECT A 12 AWG COPPER GROUND WIRE FROM SAFETY GROUND IN THE ELECTRICAL DISTRIBUTION PANEL TO D THE 4009 SAFETY GROUND STUD. a v W Z NAC4 0 A m LOCATION: 5TH FLOOR, PHONE CLOSET N a NTS 4 2 0 N '-4 (N 6 tiDRAWN BY: R.HERMANT CHECKED BY: M.GERRONE N ISSUE DATE: 2/19/19 JOB#: PROJECT#: 448:611201301 JOHNSON CONTROLS©2019 SYSTEM: FIRE ALARM SYSTEM SHEET: PANEL DETAIL AND CALCULATIONS Ni N N W " u Q NFA-501 .1- - X m ©Johnson Controls 2019.All rights reserved.Reuse,copying,modification or alteration of the drawings and other information contained herein is strictly prohibited. %1111120-11, millIlli %.7:o..zN,.. -41 (7,--ir Z Co aL p .1.1 C � C =1 m _ O p l'o V oM 0o Wpm APPLIANCES TrueAlert CONVENTIONAL APPLIANCES 0 ia vOo DEVICE MOUNTING HEIGHT REFERENCE END OF LINE RESISTOR CODES TrueAlert CONVENTIONAL —, a �o PER NFPA 72 SIMPLEX 4906 SERIES WALL MOUNTED VISUAL SIMPLEX 4906 SERIES WALL MOUNTED MULTI-CANDELA AUDIBLE/VISUAL Go0Ce a t8 VISUAL APPLIANCE MOUNTING HEIGHT CONSIDERATIONS IN SLEEPING ROOMS luilii . 1. MIN DISTANCE IN SLEEPING ROOMS IS 24"(610mm)FROM CEILING TO TOP A/C SUPPLY NOTE:REFER TO PANEL/MODULE AND DEVICE OR RETURN INSTALLATION INSTRUCTIONS FOR PROPER ® STANDARD ELECTRICAL BOX ELECTRICAL BOX ® STANDARD ELECTRICAL BOX ....--jd • OF LENS FOR 110CD STROBES WITHIN 16'OF THE PILLOW THE 4"REQUIREMENT FOR SMOKE DETECTORS HAS ELECTRICAL BOX o MOUNTING 4"SQUARE ELECTRICAL OX Q MOUNTING 4"SQUARE BO) -- 2. 177CD STROBES,USED IN SLEEPING ROOMS,CAN BE WITHIN THE 24" DIFFUSER BEEN REMOVED FROM THE 2010 EDITION OF NFPA 72 TERMINATIONS. -\ oI ®® DEEP oji 1-1/2"DEEP (610mm)MINIMUM DISTANCE FROM THE CEILING.THE HIGHER INTENSITY REFERENCE BAN)NUMBER FIRE ALARM '' 4" NOTE:MEASUREMENTS MODEL OHMS - WATTS CIRCUIT TYPE PANEL/MODULE SURFACE MOUNT ADAPTERC ° SURFACE MOUNT IS TO COMPENSATE FOR A POSSIBLE SMOKE LAYER. 3'(914mm) NUMBER 1 2 3 4 5 o/ SKIRT 15/8"(41mm)DEEP. \�`-` MINIMUM (102mm} SHOWN ARE TO THE CLOSEST O ADAPTER SKIRT 15/8 / CEILINGR 4081-9001 733-892 2.2K RED RED RED GLD N/A 1/2 ANNUNCIATOR(4300) 4004,4010(TROUBLE) , CONDUIT CUTOUTS ARE viiiiiiiiiiiiiiiiiii/iiiriiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii ////iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii ///// \\\\\w/iiiiiiiiiiiiiiiiiriiiiiii ///////////////////////7 / / EDGE OF THE DETECTOR. �, o —�" �, o (41mm)DEEP.CONDUITt — ( t" N.O.INITIATING PULL,SMOKE, 4004*,4004R,4005*,4006, PROVIDED ON ALL FOUR SIDES. r., \ t 4081-9002 733-893 3.3K ORG ORG RED GLD N/A 1 HEAT,WATERFLOW,TAMPER,ETC 4100,4120,4100U,ZAMs D '' o • CUTOUTS ARE PROVIDED SURFACE MOUNTING NFPA 72 AUDIBLE APPLIANCE 6"MIN �� o or) SURFACE MOUNTING �'; o � ° ON ALL FOUR SIDES. CEILING MOUNTED 4J% W. FOR CEILING HEIGHTS LESS THAN HEIGHT SHALL BE SMOKE/HEAT (102mm) 24 PT.I/O SWITCH SUPV. 4605-7401,4100 SERIES �, 1� .� o CLICK HERETO c {�► .* THE VISUAL LENS MOUNTING SHALL BE (152.4mm MIN)BELOW FINISHED CEILING 12"(MAX) CURRENT LIMITED N.O.INIT. 4090-9001 IDNET IAM(EOLR) ' CHANGEWIRING ` WITHIN 6"(150mm)OF THE CEILING. _ ACCEPTED HERE 0 �_ (305mm MAX) 4081-9003 733-896 4.7K YEL VLT RED GLD N/A 1/2 NOTIFICATION(DACT) 2080 9024 STYLE, (� O, gra 4004,4005,4090-9001 ( (-)(+) (-)(+) �, CANDELA INTENSITY ��� I • , HEAT DETECTORS N.O.INITIATING PULL SMOKE, IDNET IAM 2190-9173 CANDELA INTENSITY ' _ + — -)(+ I NEVER HERE I 4081-9004 733-886 6.8K BLU GRY RED GLD N/A 1/2 HEAT,WATERFLOW,TAMPER,ETC MAPNETII 2 PT I/O w� PLUG ACCESSIBLE FROM iirpoiN;* / PLUG ACCESSIBLE FROM —�, )I {�`F IRE. F1RVJ F�I� 4 20MA ZAM{TROUBLE) ��/ REAR OF HOUSING ',MI. � � ��� REAR OF HOUSING :�' e' � '•'e AUDIBLE ONLY WALL MOUNTED �� t ',.---.-7I'll I �,,,� AUDIBLE/VISUAL SMOKE/HEAT /f CURRENT LIMITED N.O. �� �`'1/ �� UM ill �1'��/ &VISUAL ONLY TO EXIT DOOR DETECTOR) 4081-9005 733-984 1.8K BRN GRY RED GLD N/A 1/2 INITIATING(IN LINE) 4090-9001 IDNET IAM L (-) (-) TO NEXT DEVICE APPLIANCES 90"MIN(2286mm MIN)ABOVE FINISHED 5'(MAX) 4005,4090-9001 IDNET JAM ` \� TO NEXT FLOOR(OTHER MOUNTING HEIGHTS SHALL (1524mm) 4081-9006 733-890 560 0 GRN BLU BRN GLD N/A 1 N.C.INITIATING(EOLR) TOP OF LENS: NAC CIRCUIT• ,OR EOL TOP OF LENS: (} {} 4100,4100U 96"(2044mm)A.F.F MAXIMUM (+) (+) RESISTOR N..._ 96"(2044mmj A.F.F MAXIMUM NAC CIRCUIT' DEVICE OR SYNCHRONIZE MORE BE PERMITTED BY THE AH1 PROVIDING IT 14081-9007 733-891 1.2K BRN RED RED GLD N/A 1 N.C.INITIATING(EOLR) 4005 Q� FOR CEILINGS<86"(2180mm)AF.F: (+} (+} EOL RESISTOR THAN TWO APPLIANCES MEETS THE SOUND LEVEL OUTPUT REQUIRED.) 4004,4005,4006,4008,4009, <O 6"(150mm)FROM CEILING TERMINATION VIEW:REAR OF DEVICE FOR CEILINGS<86"(2180mm)A.F.F.: MAGNETIC 5^ 14081 9008 733 894 lOK BRN BLK ORG GLD N/A 1/2 NOTIFICATION <=6"(150mm)FROM CEILING TERMINATION VIEW:REAR OF DEVICE IN ANY FIELD OF VIEW. r 4n�0.4100.41000 CLASS B WIRING 96"MAX(NFPA,ADA) DOOR i (127mm) 14081-9009 733-912 20 0 RED $LK BLK GLD N/A 1 TO MR-101 RELAY COIL 4005 8 POINT I/O BOTTOM OF LENS: WIRING NOTES BOTTOM OF LENS: CLASS B WIRING (2440mm MAX) HOLDER 1 SIDE WALL N.C.INIT.(ACROSS CONTACTS) 4005*,4090-9001 IDNET LAM 80"(2032mm)A.F.F.MINIMUM 80"(2032mm)A.F.F.MINIMUM WIRING NOTES ABOVE FINISHED FLOOR24 PT.I/O(ACROSS CONTACTS) 4605-7401,4100 SERIES 1. MAINTAIN CORRECT POLARITY ON TERMINAL 40819010 733 973 1K BRN BLK RED GLD N/A 1 ,o TO TOP OF LENS F FINISHED CURRENT LIMITED N.O.INIT. 4090-9001 IDNET IAM MOUNTING OPTION "B" CONNECTIONS. MOUNTING OPTION "B" 1. MAINTAIN CORRECT POLARITY ON TERMINAL REF.80"MIN(IBC) DS DOOR WALL - (IN SERIES WITH CONTACT) 2. ALWAYS CUT CONDUCTORS AND SECURE UNDER CONNECTIONS. (2032mm MIN) REF.96" 80"MIN(ADA) WIDTH 4081-9011 733-974 100 0 BRN BLK BRN GLD N/A 1/2 ANNUNCIATOR(N2) 4006.4008,4010 TERMINALS.NEVER LOOP WIRES UNDER TERMINALS. 2. ALWAYS CUT CONDUCTORS AND SECURE UNDER MAX(IBC)(2440mm MAX) (2032mm MIN) MANUAL PULL LESS 3" - 4081-9012 733-985 22K RED RED ORG GLD N/A 1/2 SPEAKER CIRCUIT 4003 TERMINALS.NEVER LOOP WIRES UNDER TERMINALS. ABOVE FINISHED FLOOR 80"MIN(NFPA) FIRE STATION (76mm) PHONE 4081-9013 734-086 4.99K YEL WHT WHT BRN BRN 1/2 3. ANY WIRE SPLICES TO BE MADE BY LISTED AND AHJ (2032mm MIN) N.C.INITIATING(SECURITY APPROVED METHODS. 3. ANY WIRE SPLICES TO APPROVED METHODS.BE MADE BY LISTED AND AHJ TO BOTTOM OF LENS 1^ 4081-9014 734-092 2.4K RED YEL RED GLD N/A 1/2 MONITORING EOLR) 4090-9001 IDNET IAM a ■. CURRENI LIMI1ED N.O.(NIT. MOUNTING OPTIONS I 1 14081-9015 734-093 1.5K BRN GRN RED GLD N/A 1/2 (SECURITY MONITORING EOLR) 4090-9001 IDNET IAM MOUNTING OPTIONS NOTE:REFER TO THE PROPER DEVICE 48"MAX(ADA)(1219mm) OPTION1 DESCRIPTION (NOTE OPTION1 DESCRIPTION NOTE INSTALLATION INSTRUCTIONS I 4081-9016 734-149 150K BRN GRN YEL GLD N/A 1/2SINGLE GANG BOX,1-1/2"(64mm)DEEP 48"MAX(NFPA,ADA)(1219mm MAX) 14081-9017 734-171 3.9K ORG WHT RED GLD N/A 1 A SINGLE GANG BOX,1-1/2"(64mm)DEEP BY OTHERS.WHEN SURFACE A BY OTHERS.WHEN SURFACE MOUNTING USE 4905 9937 FOR BACKBOX MOUNTING HEIGHT. 42"MIN(NFPA)(1067mm MIN) MEASUREMENTS SHOWN ARE f 4081 9018 734-168 BRN BLK ORD GLD N/A 1 7 CONSTANT SUPV.NAGS 4100-1260 B 4"(102mm)SQUARE BOX,1-1/2"(38mm)DEEP,MINIMUM MOUNTING USE 4905-9937(RED)OR B 4"(102mm)SQUARE BOX,1-1/2"(38mm)DEEP,MINIMUM (RED)OR 4906-9940(WHITE)SKIRT 378-090 8.2K GRAY RED RED GLD N/A 1/2 SECURITY MONITORING(EOLR) 4100.4100U 4906-9940(WHITE)SKIRT FINISHED TO TOP OF PULL HANDLE 378-046 5.6K GRN BLU RED GLD N/A 1/2 N.O.SECURITY MON.(SERIES) 4100,41000 C 2 GANG BOX,1 1/2"(38mm)DEEP C 2 GANG BOX,1-1/2"(38mm)DEEP FLOOR1 378-069 12K BRN RED ORG GLD N/A 1/2 N.C.SECURITY MON.(SHUNT) 4100,4100U D SIMPLEX 2975-9145,7-7/8"H x 5-1/8"W x 2-3/4"D ORDERED SEPARATELY D SIMPLEX 2975-9145,7-7/8"H x 5-1/8"W x 2-3/4"D ORDERED SEPARATELY *USE WITH RETROFIT OR HIGH CURRENT MODULE (127mm x 98mm x 56mm)REQUIRES 4905-9931 PLATE (127mm x 98mm x 56mm)REQUIRES 4905-9931 PLATE 1. FOR ADDFT1ONAL MOUNTING OPTIONS,DOWNLOAD DATA SHEET 4906-0002 FROM HTTP://WWW.SIMPLEX-FIRE.COM 1. FOR ADDITIONAL MOUNTING OPTIONS,DOWNLOAD DATA SHEET 4906-0002 FROM HTTPJ/WWW.SIMPLEX-FIRE.COM LA LU I ..... M 3 vVI 0/ .i O I 4.9 Q m LL M N O N en W CO en ,-1 1p 'f, M W corft- W al .J W �c'r' O i M J :=1"1/ L1 i Z W '(NI w .5 .�.... z o 0 iccV J .J v--I I—. C !O O O d L J N I d J 3 3 c 0 I s c LU w 2 m v w Q I- Z d a v w O V C Q v W Q 0 a O J V1 , Ix M rN M 0' O N O1 '-I o DRAWN BY: R.HERMANT P, CHECKED BY: M.GERRONE to ISSUE DATE: 2/19/19 106#: PROJECT#: 448:611201301 JOHNSON CONTROLS©2019 SYSTEM: FIRE ALARM SYSTEM SHEET: WIRING TYPICALS N N N W - V FA-774 01 O X M L. Z Z A. f A. i 1 Z - ©Johnson Controls 2019.All rights reserved.Reuse,copying,modification or alteration of the drawings and other information contained herein is strictly prohibited.