Loading...
Plans (64) M EC2020-OO 142 J EINISII FEDERATION T • I • LI-S ARCHITECTS 720 NW Davis 503.221.1121 a= Suite 300 503 221.2077 L RECEIVEDPortland OR 97209 www.lrsarchitects.com MAR 1 2 2020 9900 SW G re e n u rRd , s u e220 T . a rd , OR 97223 CITY OF TIGARD BUILDING DIVISION D /Vb. IS PERMIT SET _ 02 . 19 . 20 ,,,,,,,, OFFICE copy ( ExANOERAL ae OG '61 PROJECT DIRECTORY CODE SUMMARY BIDDER DESIGN NOTES (CONT.) r) ��-a)i�� 0 TIGARD,OREGON OWNER REPRESENTATIVE: I. PROJECT INFORMATION: AND PAY FOR ADDITIONAL DRAWINGS AND SPECIFICATIONS REQUIRED FOR `` a MADRONA GREENBURG,LLC CONTACT PERSON PROJECT NAME: JEWISH FEDERATION T.I. PERMITS. /'�F 0* PROJECT ADDRESS: 9900 SW GREENBURG RD 3. GC TO COORDINATE WITH ALL SUBS ON CODE REQUIRED ACCESS PANELS IN V 210 S.W. MORRISON ST, SUITE 600 JULIA WINKLER SUITE 220 CEILINGS AND WALLS.ALL NEW ACCESS PANELS TO HAVE DOOR FACED RECESSED PORTLAND, OR 97204 JULIA@WINKLERCOMPANIES.COM TIGARD, OR 97223 FOR GYPSUM BOARD INFILL WITH CONCEALED FLANGE FOR GYPSUM BOARD MAP/TAX LOT: 1S126DC03300 INSTALLATION, CONCEALED HINGES AND PUSH TO RELEASE LATCH. BUILDING TYPE: V-B BUILDING OCCUPANCY: B- BUSINESS �"N AREA OF WORK: NEW SHARED CONFERENCE RM.: 738 R.S.F. MECHANICAL- BIDDER DESIGN Ggrden CONSULTANT: RedTa4 Goll Center G , ,,,e-whitlord SUITE 220: 4,450 R.S.F. 4, MECHANICAL SYSTEM AND REQUIREMENTS ARE BIDDER DESIGN. SUBMIT PLANS ARCHITECT: PROJECT DESCRIPTION: T.I. INCLUDES CREATING A NEW BUILDING CONFERENCE ROOM, AND SPECIFICATIONS TO ARCHITECT FOR COORDINATION WITH ARCHITECTS 1 9 Panda Express' SITE LOCATION LRS ARCHITECTS CONTACT PERSON MINOR DEMOLITION OF INTERIOR PARTITIONS, CREATE 3 NEW DRAWINGS. PLANS TO INCLUDE THERMOSTAT ZONING APPROVED BY OWNER AND e 720 NW DAVIS, STE 300 PETER KIM OFFICES, 1 NEW WORK ROOM, 1 NEW STAFF RM., & 1 ARCHITECT PRIOR TO CONSTRUCTION. M CONFERENCE RM. "".,''-` a PORTLAND, OR 97209 PKIM@LRSARCHITECTS.COM 5. PREPARE A WRITTEN SCOPE OF HVAC WORK WITH BID. THIS IS TO INCLUDE NEW WAShi lglnn Snow 1!.JURISDICTIONAL CODES: EQUIPMENT, NUMBER OF ZONES, DESCRIPTION AND QUANTITY OF CONTROLS ANDo WWW-LRSARCHITECTS.COM THERMOSTATS, ETC. OWNER WILL REVIEW SCOPE OF WORK PROPOSED PRIOR TO ® 9 OSO11r wst 2018 INTERNATIONAL BUILDING CODE (IBC) �GreenhwgRoad T:503.221.1121 2019 OREGON STRUCTURAL SPECIALTY CODE (OSSC) ACCEPTANCE OF BID. 2018 INTERNATIONAL EXISTING BUILDING CODE (IEBC) 6. PROVIDE CERTIFICATION THAT AIR QUALITY REQUIREMENTS OF CURRENT CODES Metzger GENERAL CONTRACTOR: 2019 OREGON MECHANICAL SPECIALTY CODE (OMSC) WILL BE MET FOR EACH OCCUPANCY USE WITHIN THE TENANT IMPROVEMENT 2018 INTERNATIONAL FIRE CODE AREA. •--', 0 JHC COMPANIES CONTACT PERSON ` �PJvlson'sFloorCaser5 2019 OREGON ZERO ENERGY READY COMMERCIAL CODE (OZERCC) 7. VERIFY THE SUITABILITY AND CONDITION OF SCHEDULED EQUIPMENT TO BE 11125 SW BARBUR SVLD PATRICK MCCARTHY 2017 OREGON PLUMBING SPECIALTY CODE (OPSC) RE-USED OR RELOCATED. DETERMINE ITEMS THAT NEED TO BE REPAIRED OR r' PORTLAND,OR, 97219 PMCCARTHY@JHC-COMPANIES.COM 2017 OREGON ELECTRICAL SPECIALTY CODE (OESC) REPLACED. PRICE THESE ITEMS SEPARATELY AND AS EXCEPTIONS/ 2009 ICC-ANSI A117.1 CLARIFICATIONS IN BID : C? T:503.624.7100 } `. III.ADA ACCESSIBILITY UPGRADES 8. BALANCE HVAC SYSTEM TO TENANT AND BUILDING OWNERS SATISFACTION. TOUR g 1. BUILDING HAS BEEN UPGRADED ACCORDING TO THE ACCESSIBILITY UPGRADES LIST AS EXISTING CONDITIONS AND CONTACT OWNER FOR QUESTIONS PRIOR TO BID. OUTLINED IN OSSC 3411. 9. CLEAN ALL NEW AND EXISTING HVAC GRILLS AND DIFFUSERS SCHEDULED TO u � '� REMAIN.ALL DUCTWORK BEHIND THE GRILLS SHALL BE A UNIFORM DARK COLOR. 10.AT COMPLETION, PREPARE AND SUBMIT AN AIR BALANCING REPORT TO THE QRLldmg Depagnteni . VI. EMERGENCY SYSTEM STANDARDS: OWNER. DRAWING INDEX 11.PROVIDE 100% FRESH AIR SUPPLIED TO THE ENTIRE TENANT SPACE THREE CALENDAR A f DAYS PRIOR TO THE FIRST DAY AFTER SUBSTANTIAL COMPLETION. PROVIDE 100% 111 SHEET NUMBER SHEET NAME 1. IF BUILDING IS FULLY SPRINKLERED (NFPA 13). MAKE CODE MINIMUM CORRECTIONS AS FRESH AIR WITHOUT MAKING OTHER TENANTS UNCOMFORTABLE. REQUIRED PER NEW PLAN. CS COVER SHEET 2. IN BUILDINGS WITH EXISTING SMOKE DETECTORS: PROVIDE CODE MINIMUM ELECTRICAL- BIDDER DESIGN VICINITY MAP CD A100 CODE ANALYSIS CORRECTIONS AS REQUIRED. SMOKE DETECTORS TO BE TIED TO THE BUILDING ALARM SYSTEM. SCALE: NOT TO SCALE A101 MISC. CODE INFORMATION 3. IN BUILDINGS EQUIPPED WITH AN EXISTING VISUAL STROBE SYSTEM: PROVIDE CODE 12.ELECTRICAL SYSTEM AND REQUIREMENTS ARE BIDDER DESIGN. LIGHTS AND A201 DEMO & FLOOR PLANS ELECTRICAL INFORMATION ON DRAWINGS IS PROVIDED FOR REFERENCE ONLY - - , A401 DEMO & REFLECTED CEILING PLANS MINIMUM CORRECTIONS AS REQUIRED. IF A SYSTEM DOES NOT EXIST, DO NOT ADD ONE. AND IS INTENDED TO SHOW FIXTURE TYPES AND DESIGN INTENT. - • ° �Tr 4. PROVIDE EMERGENCY SYSTEM LIGHTING WITH NO LESS THAN 1 FOOT-CANDLE AT THE TRUE NORTH A980 INTERIOR DETAILS FLOOR LEVEL ALONG ENTIRE EGRESS PATH PER CURRENT NATIONAL ELECTRICAL CODE 13.SUBMIT ELECTRICAL DESIGN TO ARCHITECT FOR COORDINATION. ELECTRICAL ; '__ ,. � A981 INTERIOR DETAILS REQUIREMENT. PLANS TO INCLUDE LOCATIONS FOR ALL LIGHTING, EMERGENCY LIGHTING,AND FIRE-LIFE SAFETY FIXTURES. SUBMITTAL TO INCLUDE PROJECTS CUTSHEETS AND ', e1 5. PROVIDE EXIT SIGNAGE. EXIT SIGNAGE SHALL BE CONNECTED TO BUILDING POWER PHOTOMETRIC CALCULATIONS. ELECTRICAL DESIGN MUST BE APPROVED BY .� . SUPPLY WITH BATTERY BACK-UP FOR MIN 1-1/2 HOUR DURATION. EVERY 100' IN OWNER AND ARCHITECT PRIOR TO CONSTRUCTION. %! 'i CORRIDORS,AND IN SPACES WHERE 2 MEAN OF EGRESS ARE REQUIRED PER SECTION 14.COMPLY WITH ALL JURISDICTIONAL ENERGY CODES AND PROVIDE ENERGY ` • 1013. SEE ELECTRICAL DRAWINGS. (WI POCHE INDICATING "EXIT'TEXT SIDE OF SIGN) CALCULATIONS IF REQUIRED. �- G= ' GREENBURG COMMONS SIGNS SHOWN IN CORRIDORS ARE CEILING HUNG. SIGNS SHOWN ON WALL ARE WALL / I - „- HUNG. 15.COORDINATE ELECTRICAL REQUIREMENT FOR MECHANICAL SYSTEMS. . I ,1' PROJECT NUMBER: 220029 UNDER SEPARATE PERMIT (THROUGH DEFERRED SUBMITTAL) 6. PROVIDE CODE MINIMUM FIRE ALARM CONNECTIONS AS REQUIRED- 16.IF AN OVERRIDE SYSTEM EXISTS, PROVIDE EACH TENANT SPACE WITH AN • , ;-I. OVERRIDE SWITCH FOR FULL-SERVICE BUILDINGS. ' - •� ' 7. SURVEY EXISTING CONDITIONS OF ENTIRE FLOOR THAT PROJECT OCCURS,AND PROVIDE - _ MECHANICAL SYSTEMS NOT LESS THAN ONE APPROVED FIRE EXTINGUISHER WITH RATING OF NOT LESS THAN 17.SWITCHING FOR LIGHTING IS INDICATED IN THE DRAWING FOR REFERENCE ONLY t" JeW1Sf? Federation 2A 10B/C FOR EACH 1,500 S.F. OF FLOOR AREA OR FRACTION THEREOF. TRAVEL AND IS INTENDED TO ONLY SHOW SWITCH LOCATIONS, REQUIREMENTS FOR DUAL r° ELECTRICAL SYSTEMS, INCLUDING EGRESS LIGHTING ! ; PLUMBING SYSTEMS DISTANCE TO AN EXTINGUISHER FROM ANY PORTION OF THE BUILDING SHALL NOT SWITCHING, AUTOMATIC AREA SHUT OFF CONTROLS AND ALL OTHER CODE 1 T.I.SPRINKLER SYSTEMS EXCEED 75 FEET. PROVIDE FIRE EXTINGUISHER IN ACCORDANCE WITH CURRENT CODES. REQUIREMENTS SHALL BE THE RESPONSIBILITY OF THE BIDDER DESIGN 1 :a � f ." I l FIRE ALARM/DETECTION SYSTEMS PROVIDE NEW FIRE EXTINGUISHER AT ALL EXISTING CABINETS WHERE MISSING. ALL CONTRACTOR. PROVIDE A MINIMUM OF ONE SWITCH PER ROOM, UNLESS -1. REUSED EXISTING FIRE EXTINGUISHERS ARE TO BE INSPECTED AND/OR RECHARGED, AS OTHERWISE INDICATED. .:c NECESSARY, JUST PRIOR TO SUBSTANTIAL COMPLETION. 18.WHEN NEW LIGHT SWITCHES ARE ADDED TO ANY PORTION OF THE SUITE, - 9900 SW Greenburg Rd, 8. CONTACT OWNERS REPRESENTATIVE FOR INSTRUCTIONS WHEN SCHEDULING WORK ON REPLACE ALL EXISTING LIGHT SWITCHES WITH NEW OCCUPANCY SENSOR _FIRE SPRINKLER &ALARM SYSTEMS SWITCHES. 17." Pir.g.:,.. .-. K. Supe 220 19.PROVIDE ILLUMINATED EXIT SIGNS AT REQUIRED EXIT DOORWAYS AND WHERE NECESSARY TO INDICATE THE DIRECTION OF EGRESS WHEN THE EXIT SERVES AN ' Tigard, OR 97223 OCCUPANCY LOAD OF FIFTY OR MORE. I" -- - z 20.PROVIDE VISUAL AND AUDIBLE ALARM SIGNAL APPLIANCES INTEGRATED INTO THE GENERAL NOTES BUILDING ALARM SYSTEM AS REQUIRED BY CURRENT JURISDICTION CODES AND R "'4 REQUIREMENTS. PROVIDE ADDITIONAL ELECTRICAL SERVICE AS REQUIRED. ,,• '� 1. THE GENERAL NOTES ARE INTENDED TO CONVEY DESIGN INTENT QC /SUBMITTAL REQUIREMENTS COORDINATE REQUIREMENTS WITH BUILDING OWNER.ALARM LOCATIONS NOT •OTHERWISE STATED IN THE DRAWINGS. INDICATED ON PLANS ARE ONLY FOR REFERENCE. f dr. 2. ALL WORK SHALL CONFORM TO THE CODES REFERENCED IN THE 1. SUBMIT SUBSTITUTION REQUESTS ON CSI FORM TO ARCHITECT FOR APPROVAL. 21.PROVIDE SHOP DRAWINGS FOR ALARM SYSTEM LAYOUT AS REQUIRED BY CODE. ` ' ( ''k ARCHITECTS DECISION IS FINAL WHETHER OR NOT A PROPOSED PRODUCT IS ` ' PROJECT SUMMARY AND TO CONDITIONS AND SPECIFICATIONS OF ACCEPTABLE FOR SUBSTITUTION. 22.VERlFY SERVICEABILITY AND REUSABILITY OF EXISTING ELECTRICAL EQUIPMENT, f' 1 ALL GOVERNING AUTHORITIES. AND REPAIR OR REPLACE AS NECESSARY. 1 • 3. THE SITE PLAN AND SUITE LOCATION PLAN ARE FOR REFERENCE 2. SUBMIT COLOR DRAW- DOWNS OF PAINTS TO ARCHITECT AND OWNER FOR APPROVAL 23.VERIFY THE CAPACITY AND REUSABILITY OF EXISTING ELECTRICAL PANELS TO N ONLY. SEE ALL OTHER SHEET PLANS FOR CONTRACT DOCUMENT PRIOR TO APPLICATION. MEET PROJECT REQUIREMENTS. INFORMATION.THE PROJECT SUMMARY IDENTIFIES SOME SPECIFIC 3. APPLICATION OF MATERIALS TO SURFACES EXISTING OR PROVIDED UNDER THIS 24.KNOWN EXISTING ELECTRICAL AND PHONE/DATA OUTLETS HAVE BEEN INDICATED ON OSSC REQUIREMENTS BUT IS NOT INTENDED TO LIST ALL OSSC CONTRACT IMPLIES ACCEPTANCE AND SUITABILITY OF EXISTING CONDITIONS. THE DRAWING.ADDITIONAL EXISTING OUTLETS MAY EXIST AND SHOULD BE SITE PLAN CB REQUIREMENTS. 4. ALL MATERIALS AND PRODUCTS USED ON THE JOB SITE SHALL BE"ENVIRONMENTALLY VERIFIED BY CONTRACTOR. 4. ALL WORK INDICATED ON DRAWINGS SHOULD BE CONSIDERED SAFE", LOW ODOR,AND NON FLAMMABLE. USE OF ANY PRODUCT NOT COMPLYING WITH 25.SMOKE DETECTION DEVICES INDICATED ON THE DRAWING ARE FOR REFERENCE SCALE:NOT TO SCALE THIS CRITERIA MUST BE APPROVED BY THE BUILDING OWNER AND/OR ARCHITECT. NEW AND IN CONTRACT UNLESS NOTED OTHERWISE. ONLY. CONFIRM SPACING OF DETECTORS WITH DEVICE LISTING_ 5. CONTRACTOR WILL BE HELD RESPONSIBLE FOR ANY DAMAGE OR CLEANING 26.CLEAN AND REPAIR EXISTING SMOKE DETECTORS TO BE REUSED TO GOOD THROUGHOUT STRUCTURE DEEMED TO BE A RESULT OF HIS/HER WORK. THOROUGHLY WORKING CONDITION. TRUE NORTH CLEAN PREMISES UPON COMPLETION OF WORK, INCLUDING WASHING OF WINDOWS, SO THAT BUILDING IS READY FOR OCCUPANCY BY TENANT. INCLUDE CLEANING OF 27.CLEAN NEW, EXISTING, AND RELOCATED LIGHT FIXTURES IN PROJECT AREA, OR IN ADJACENT AREAS WITHIN AND AROUND THE BUILDING THAT ARE NOT PART OF TENANT AREAS AFFECTED BY WORK OF THIS PROJECT,AT COMPLETION OF JOB. RELAMP IMPROVEMENTS. BUT WERE AFFECTED BY TENANT IMPROVEMENT CONSTRUCTION AND REPLACE BALLAST IN LIGHT FIXTURES AS REQUIRED TO RESTORE TO OPERATIONS. REPAIR/REFINISH ANY DAMAGE TO EXISTING FINISH SURFACES. WORKING ORDER. 0 6. PROVIDE PRODUCT INFORMATION AND/OR SAMPLES OF ALL PRODUCTS AND MATERIALS 28.CLEAN AND REPAIR EXISTING EXIT SIGNS TO BE REUSED. REPLACE BATTERY AND/ :34USED IN PROJECT FOR ARCHITECT AND OWNER APPROVAL PRIOR TO INSTALLATION. OR BALLAST IF NOT IN GOOD WORKING CONDITION. _ _ m m _ 116 SHEET TITLE: ` 7. CASEWORK SHOULD ADHERE TO NORTH AMERICAN ARCHITECTURAL WOODWORK 29.COORDINATE TELECOMMUNICATIONS AND MODIFICATION TO BUILDING ALARM i . _ _ I ll E STANDARDS 3.1 2017 "CUSTOM" GRADE UNLESS NOTED OTHERWISE. SYSTEM PROVIDED BY TENANT. VERIFY WITH TENANT LOCATION OF NEW OUTLETS II CO VERSHEET 8. INTERIOR WALLS TO BE LEVEL 4 SMOOTH FINISH IN ALL AREAS, UNLESS NOTED PRIOR TO INSTALLATION. _ �I • I OTHERWISE. 30.REMOVE ALL UNUSED OR ABANDONED ELECTRICAL WIRING, EQUIPMENT,AND j •.•. !i(L .- VIII N PHONE AND DATA CABLING. CONFIRM WITH OWNER PRIOR TO REMOVAL. ALL -- ql ;« ���,-, 11.1111111 I I w 9. FLOORING DIRECTION AND SEAMING LOCATIONS ARE TO BE APPROVED BY THE WIRING AND CABLING TO REMAIN SHALL BE SUSPENDED FROM STRUCTURE AS m I• i■t%, V J �_ • E )) ARCHITECT. REQUIRED BY CURRENT CODE. , ��;'/ ��� I_ Ill 7 11 10.PRDVIDE FINISH MATERIALS MATCHING ESTABLISHED BUILDING STANDARD QUALITY, it@ =_ H - sz/ r;. UNLESS OTHERWISE INDICATED. PROVIDE COLORS APPROVED BY OWNER AND 4 W 4Pitepi 1 ARCHITECT. SPRINKLER-BIDDER DESIGN a ��,,r�i : 11.CONTRACTOR TO FILL AND PATCH EXISTING CONCRETE SLABS AND SHALL PROVIDE m k' i �� SMOOTH UNIFORM SURFACE PRIOR TO NEW FLOOR COVERINGS TO BE INSTALLED. IN 31.AUTOMATIC SPRINKLER SYSTEM SUPERVISION:ALL VALVES INCLUDING THOSE IN .. ' iii . .1 ,4„00,1,,,-..„---.4• �� Af. - -'-- L AREA WHERE FLOOR IS TO BE LEFT EXPOSED, FLOOR TO BE MADE SUITABLE FOR PITS, SHALL BE MONITORED BY UL LISTED FIRE MARSHALL-APPROVED CENTRAL ���_ - SPECIFIED FINISH LEVEL STATION. WATER FLOW AND HIGH/LOW PRESSURE FOR DRY PIPE SYSTEM IF USED.) `� e - .1-k_ . DATE ISSUED: 02.19.20 ��� W. 0 32.PREPARE SPRINKLER SYSTEM SHOP DRAWINGS FOR COORDINATION WITH �`���/ 1.-- -� '. ci BIDDER DESIGN NOTES ARCHITECTS DRAWINGS BY ARCHITECT. `moi%/r' PERMIT SET 02.19.20 33.SUBMIT PROPOSED LOCATION FOR EMERGENCY LIGHTING, STROBES, SMOKE >!•. d GENERAL DETECTION AND SPRINKLERS (IF REQ'D) TO ARCHITECT FOR REVIEW. �� a ice" i /ii -� N 1. WARRANTY ALL PARTS, LABOR, EQUIPMENT, AND MATERIAL PROVIDED UNDER THIS 0 CONTRACT OF A PERIOD OF ONE YEAR, UPON FINAL COMPLETION OF CONTRACT. b 2. OBTAIN AND PAY FOR ALL PERMITS AND FEES TO COMPLETE THE WORK. OBTAIN C 15 r. N CS _ z m AREA OF WORK- 2nd FLOOR 0. ecoSHEET: E a SCALE: NOT TO SCALE cRsa,�n�tecrs.rnc.�zoza r~ 0 E 2 Q. TRUE NORTH PLAN NORTH J H II I J X u I �I - • I II \ _i ® �� 1E) L riliMS I` -- I _ I \+ ,� X \�. ice' _ I\ it \ N /�' + ., " ' " ARCHITECTS I . , - ..._ + ,< _____11 4. 1 ' f 720 NW Davis 503.221.1121 l Suite 300 503 221.2077 1-1I 1L r ______i____L___ - _ I 1 Portland OR 97209 www.Irsarchitects.com 11110111 uaa,inim N r I lr j X + _ amMili rANNITA Inamwasil t -.41 mil + --- ,i 4. ._ 451D dik.,4... N 4 / + / 1r ==----:: ..___ ____,_ ..c.,,N ,,,A, _i um ALVy_ In 4 _ -I + ___ ____.,. (...5 A EXANDER B. BALOG nil -...,, en --,tvi . N -,,,,,_ ---__,,,___ - . A i',4V.Z.m...e / q I. — Hu ,,J, ``�� \ -- + X TIGARD,OREGON �_ __1 4 - y , I�i -�.�� IIS\ 11>< + OF o IM IMI am „,,J ,... ,, 1 -,,.. . , \ 1 mil W ■e illL, _1 1-11\ _+ + -T II rh =e! �� I NA - - T R7 CONSULTANT: —Iimill • # A , 11 ... MI ftIx:j 1U ] 1>t- -1 I! ci II i I� I �� }�� \ + + f 7C-- ti __ _ /. - �Y ash L --.- _ I I' ■~ III I I./ ME 1 1 r II � MEM �� �� ft I I �� = _1 V _ I- + _■ Inlie \E -\ 11 _,_ t.ID NE TR \ rall . e + Mid + I \ MEM 8c5" Mil 5.7.= ____ __ MI . c_fLTD i Irlogm mil im , ,......1 I.. , 1 I - ii __ I■� 1111 U ■ ■I ■ ■ + I �� - - — ■ r 1 ■ LIGHTING LEGEND ■�� Ir I LIGHTING LEGEND IT■�`\■I 7 �■ I� ■■■--�,- 6* I■ ` EXISTING BUILDING STANDARD LIGHT FIXTURE ■■ 1111111i1M i\I ■ ` EXISTING BUILDING STANDARD LIGHT FIXTURE ■ -I-IIM-I �{ ■ �`���_'� EXISTING LIGHT FIXTURE TO BE REMOVED OR RELOCATED ■ + �1 N s \ PROVIDE NEW OR RELOCATED BUILDING STANDARD 2x4 10111111.1111111111_1111111111 -- II ■ �`�--�'� ■ �= + =■ ■ LIGHT FIXTURE I 1. `. _ I "p _ LIII _ PROVIDE NEW OR RELOCATED BUILDING STANDARD 2xD © LIGHT FIXTURE PROJECT NUMBER: 220029 ■■■IME1 M + - l ■ -I ailli= IIII/, ■ �■ RCP LEGEND ■ I Jewish Federation RCP LEGEND — ■_`=I- \ _ EXISTING2x4 ACOUSTICAL SUSPENDED CEILING II WI -I - T.I. I I + + 11.1 / 2x4 ACOUSTICAL SUSPENDED CEILING EXISTING_E ll 8'-5- CEILING ELEVATION ■ O■ 8'-5" 9900 SW Greenburg Rd, ■■ M I _-`—I'■ co CEL GTAG ■ 1\1 mu MN + ■ _-- X EXISTING HVAC SUPPLY (R)- RELOCATE t — CEILING ELEVATION TAG Suite 220 + X EXISTING HVAC SUPPLY Tigard, OR 97223 ■-`-I EXISTING HVACRETURN—I __ / 1EXISTINGHVACRETURN'' �" '- ® ®+ EXISTING EXIT SIGNS(W/INTEGRAL ARROW WHERE w"'g""'� /■ -IOCCURS) ■ ■ -,■ I ®+ EXITSIGNS (W/INTEGRAL ARROW WHERE OCCURS) ■��■■1 I N ■ � 'EXISTING SPRINKLER EXISTINGSPRINKLERMI ■■I1 � - aa, 6► + 1 k 11•111=-I -- —i -- I N NEW OR RELOCATED !' �I _�� ___ , �__ l T THERMOSTAT �I NM Immo! I `--I _ II_►1mini ' 11111 BEI , — + = L1111 Ell ■ E_I■■� I_1iim � I E I . =. - N N 4 EDED 1. DEMO REFLECTED CEILING PLAN 2. REFLECTED CEILING PLAN N SCALE: 1/8"= 1'0" SCALE: 1/8"= 9'-0" N SHEET TITLE: GENERAL NOTES KEYNOTES GENERAL NO TES KEYNOTES DEMO & 0 1 A. THIS DRAWING DEPICTS EXISTING CONDITIONS FOR REFERENCE 1X DEMO PORTION OF EXISTING DEMISING WALL. LEAVE 2" FROM EXISTING A. THIS DRAWING DEPICTS EXISTING CONDITIONS FOR REFERENCE ONLY. VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR NEW FINISHED GYPSUM BOARD HEADER 2" BELOW EXISTING CEILING REFLECTED ONLY. VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO START OF CEILING GRID SYSTEM FOR NEW GYPSUM BOARD HEADER. SEE 2/A401 TO START OF WORK AND REPORT ALL DISCREPANCIES TO ARCHITECT. GRID. PROVIDE LATERAL BRACING EVERY8'-0" 0.C. FOR SUPPORT. SEE 8 WORK AND REPORT ALL DISCREPANCIES TO ARCHITECT. FOR ADDITIONAL INFORMATION. B. ALL ACCESS PANELS, DIFFUSERS AND NON-NOTED FIXTURES TO BE FINISHED TO MATCH ADJACENT CEILING FINISHES, DETAIL X/A980 CEILING PLANS C. VERIFY ALL MOUNTING HEIGHTS ONSITE WITH ARCHITECT PRIOR TO INSTALL. B. DIMENSIONS ARE TO FACE OF FINISH, UNO. DIMENSIONS NOTED TAKE D. LIGHT FIXTURES TO BE CENTERED IN ROOM,AREA,AND/OR ACOUSTIC PANEL UNLESS NOTED OTHERWISE. C PRECEDENCE OVER SCALE. B. ALL ELECTRICAL WORK IS DESIGN BUILD- EXISTING & NEW LIGHT FIXTURES SHOWN FOR REFERENCE ONLY. VERIFY C. PROTECT ALL ADJACENT AREAS DURING DEMOLITION AND FROM DUST EXISTING CONDITIONS AND REPORT ANY DISCREPANCIES TO ARCHITECT. SUBMIT ELECTRICAL PLANS TO ARCHITECT FOR AND TRASH INTRUSION. REVIEW PRIOR TO CONSTRUCTION. CLEAN & RESTORE ALL LIGHTS TO WORKING ORDER PRIOR TO JOB COMPLETION. D. ALLRDEMOLITIONIDEAD WORK TO NG ONCONFEXISTINGRM O CURRENT OSHA STANDARDS. C. ALL MECHANICAL WORK IS DESIGN BUILD-EXISTING& NEW DIFFUSERS SHOWN FOR REFERENCE ONLY. VERIFY EXISTING PROVIDE ADEQUATE BRACING ON CEILING FRAMING CONDITIONS AND REPORT ANY DISCREPANCIES TO ARCHITECT. DRAWN BY: OM SYSTEM PRIOR TO DEMOLITION, D. SUBMIT MECHANICAL PLANS TO ARCHITECT FOR REVIEW PRIOR TO CONSTRUCTION. CLEAN ALL DIFFUSERS PRIOR TO JOB EE. CEILING CONFIGURATION TO REMAIN, UNO. COMPLETION. DATE ISSUED: 02.19.20 3 E. SUBMIT PROPOSED LOCATIONS FOR EMERGENCY LIGHTING, STROBES, SMOKE DETECTION & SPRINKLERS TO ARCHITECT PERMIT SET 02.19.20 FOR REVIEW AND COORDINATION PRIOR TO CONSTRUCTION. • F. REPLACE ALL DAMAGED CEILING TILES & GRID TO MATCH EXISTING BUILDING STANDARD. cn G. WHERE NEW LIGHTS ARE ADDED- MATCH EXISTING BUILDING STANDARD TYPE AND FINISH. N O O N 0 0 O 0 C c m 0 „,, A 4 0 1 SHEET: U- LRS Architects,Inc.©2020 g, E Y n