Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans (52)
F PS2020-00041 . , r= OFFICE COP RECE � III 1141( Y `� CS)C.9 MAR 18 • (0(0 CITY OF iliat\ri4. \ c)c)AR: ` C ;o�7� cfC : i . Johnson SENTRY BUILDING DIVISION {n LIANCE Controls p. tsa r �e.H to rC2 u, s''. t: 10 - - Q (Doe.) 0)km) O 'b' ow53 cc i.ii DRAWING INDEX LEGENDS APPLICABLE CODES & STANDARDS JOHNSON CONTROLS CONTACTS to- MYW o cc)uj5 JURISDICTIONS WITHIN THE STATE MAY HAVE AMENDMENTS TO THE STATE ADOPTED CODE.CHECK Sales Representative Drawings Prepared az WITH THE LOCAL JURISDICTION AUTHORITY FOR MORE DETAILS. Oregon Structural Specialty Code,2019 Edition BRYAN ADAMS RON HERMANT BRYAN.ADAMS@JCI.COM RONALD.HERMANT@JCI.COM Oregon Fire Code,2019 Edition PHONE:503-683-9000 PHONE:503-683-9000 Oregon Mechanical Specialty Code,2019 Edition Scheduling Drawings Reviewed By Oregon Electrical Specialty Code,2017 Edition MIRANDA CASTLE ALEKSANDR MAZHNIKOV MIRANDA.CASTLE@JCI.COM ALEKSANDR,MAZHNIKOV@JCI.COM National Fire Alarm Code(NFPA 72),2016 Edition PHONE:503-683-9000 PHONE:503-683-9000 NICET LEVEL II #142932 Sheet List Table Sheet Sheet Title Number FIRE ALARM SYMBOL LEGEND IFA-001 COVER SHEET WIRE IFA-101 10TH FLOOR DEVICE PLACEMENT PLAN,CALCS&WIRING TYPICALS SYMBOL DESCRIPTION BRAND MODEL BACKBOX TYPE VALIDITY OF PERMIT PANELS THE ISSUANCE OF A PERMIT BASED ON CONSTRUCTION TPR4 VAC 4100ES TRANSPONDER FIRE ALARM TRANSPONDER PANEL, 120 SIMPLEX 4100-9600 SIMPLEX CABINET WA + DOCUMENTS AND OTHER OCCUPANCY TYPE(S): SPRINKLER PROTECTION: DATA SHALL NOT PREVENT THE CODE OFFICIAL FROM NOTIFICATION APPLIANCES B BUSINESS GROUP BUILDING IS FULLY SPRINKLED REQUIRING THE CORRECTION # CONVENTIONAL MULTI-CANDELA STROBE,WALL MOUNT,RED, SIMPLEX 4906 9101 SINGLE GANG 1 1/2"D _ V CLEAR LENS,FIRE OF ERRORS.QSSC 105.4 MISCELLANEOUS DEVICES JB JUNCTION BOX BY OTHERS ' BYOTHERS E SCOPE OF WORK PROJECT DIRECTORY #K I END-OF-LINE RESISTOR 3.3K(EOL) 4081-9002 I { I END-OF-LINE RESISTOR 4.7K(EOL) SIMPLEX I 4081-9003 MODIFY EXISTING FIRE ALARM SYSTEM: PROVIDE NEW DEVICES AND RELOCATE EXISTING DEVICES AS SHOWN ON DRAWINGS. Site Johnson Controls District-448 I END-OF-LINE RESISTOR 6.8K(EOL) 4081-9004 END-OF-LINE RESISTOR 10K(EOL) ! 4081-9008 ALL NEW WIRING TO BE CLASS B. LINCOLN TOWER 10260 SW GREENBURG RD 6305 SW ROSEWOOD ST,SUITE A EXISTING DEVICES ARE SHOWN SHADED FOR REFERENCE THE EXISTING FIRE ALARM SYSTEM SHALL NOT BE DISCONNECTED OR TAKEN OUT OF SERVICE WITHOUT WRITTEN PERMISSION FROM THE OWNER. IT TIGARD,OR 97223 PHONE: OR 97035 503-683-9000 IS THE CONTRACTOR'S RESPONSIBILITY TO COORDINATE WITH THE OWNER THE TIMING OF ANY EXISTING FIRE ALARM SYSTEM DEMOLITION WORK. FAX: 503-675-6521 SERVICE:503-683-9001 Owner Installer DESIGN STATEMENT SHORENSTEIN REALTY SERVICES POINT MONITOR CORPORATION 10220 SW GREENBURG RD 7869 SW NIMBUS AVE TIGARD,OR 97223 BEAVERTON,OR 97008 'ci;a DESIGN IS FOR FIRE ALARM NOTIFICATION OF THE OUTLINED AREA OF WORK. g ACCEPTABLE CABLE TYPES N FIRE ALARM WIRE LEGEND 4 CIRCUIT DESCRIPTION CONSTRUCTION GAUGE CIRCUIT PROPERTIES a a = z 0 ci o V VISUAL 2 COND.SOLID 14 AWG X X E CONDUIT SIZE MAX CONDUCTOR AREA CONDUIT SIZE MAX CONDUCTOR AREA 1 I 1/2' 0.12221SQ.NINCH* 1-1/2' 0.5981SQ INCH* ABBREVIATIONS LEGEND DEVICE TAG LEGEND 314' 0.213 SQ INCH* 1-112* 0.814 SQ INCH* F 1 1' 0.346 SQ INCH* 2' 1.342 SQ INCH* ' 8 .40%CONDUIT FILL PER N.E.C. SW=SHIELDED TWISTED PAIR AC= ABOVE CEILING NEC=NATIONAL ELECTRIC CODE ITEMS SUCH AS CAPACITANCE BETWEEN CONDUCTORS AND WIRE GAUGE CAN BE CRUCIAL TO THE CIRCUIT DESIGN OF THIS SYSTEM INSTALLATION. AFF=ABOVE FINISHED FLOOR NFPA =NATIONAL FIRE PROTECTION ASSOCIATION ami THE INSTALLING CONTRACTOR IS RESPONSIBLE FOR SELECTING AND INSTALLING CABLE MANUFACTURER AND MODEL THAT MEETS OR EXCEEDS AHJ=AUTHORITY HAVING JURISDICTION NEC=NOT IN CONTRACT 0 THE ABOVE REQUIREMENTS.RECOMMENDED CABLE MANUFACTURERS AND MODEL NUMBERS ARE AVAILABLE UPON REQUEST. ALM=ALARM NPU=NETWORK PROCESSING UNIT }' ANN=ANNUNCIATOR NTS=NOT TO SCALE c BMS=BUILDING MANAGEMENT SYSTEM PAP=PRE-ACTION PANEL S C = CEILING MOUNTED RC=EXISTING TO REMOVE AND COVER v CD= CANDELA RATING RD=EXISTING DEVICE TO BE RELOCATED DET= DETECTOR RL= RELOCATED DEVICE o 4 DGP= DATA GATHERING PANEL RR= REMOVE EXISTING&REPLACE WITH NEW c i _ E= EXISTING TO REMAIN SCC = STATUS COMMAND CENTER - DEVICE DESIGNATOR §_ EOL=END OF LINE SLC =SIGNALING LINE CIRCUIT -' EPO = EMERGENCY POWER OFF SMK = SMOKE CIRCUIT DESIGNATOR 00o FAA =FIRE ALARM ANNUNCIATOR SUPV = SUPERVISORY o FACP=FIRE ALARM CONTROL PANEL TAC = TRUEALERT ADDRESSABLE CONTROLLER 0 FATC = FIRE ALARM TERMINAL CABINET TRBL= TROUBLE nQ - FBO =FURNISHED BY OTHERS TS= TAMPER SWITCH N83-1 4 FCC =FIRE COMMAND CENTER TYP = TYPICAL W FSD=FIRE SMOKE DAMPER UON=UNLESS OTHERWISE NOTED VISUAL.AUDIBLE OR AN DEVICE FIR=FIRE ALARM TRANSPONDER VCC = VOICE COMMAND CENTER H=HIGH HUMIDITY VT= VALVE TAMPERCD Et a) HT=HEIGHT W =WATTAGE 'i' HVAC =HEATING VENTILATION&AIR CONDITIONING WI= WITH IlmiCO M v IMS=INFORMATION MANAGEMENT SYSTEM W/O= WITHOUT N 0.. MAX= MAXIMUM WF= WATERFLOW W Lj,i N les MIN=MINIMUM WG= WIRE GUARD Z >mi W c• E. N/A=NOT APPLICABLE WP= WEATHERPROOF o NAC=NOTIFICATION APPLIANCE CIRCUIT XP=EXPLOSION PROOF W O t7 Ce o NDU=NETWORK DISPLAY UNIT 0 ZSQ c 0 SYSTEM SEQUENCE OF OPERATIONS 0 Z oCO Cs N V10 < E W Zc0 _Itl� _, ' - E 0 E I-- • w 3 0 t . m c 0 z , 0 '> v ce 1- z ce 0 Q 0 0 I C.) tY H z f¢- a co co a Q t o U z z z 0_ - PI ¢ GENERAL NOTES RISER DIAGRAM _ _ 0 0 z z C3 us 0 > co w ....1 Y Z z 0 z 0 NI 1. THESE DRAWINGS DEPICT GENERAL LOCATIONS OF LIFE SAFETY EQUIPMENT&FIELD DEVICES.EXACT ROUTING OF CONDUITS IS TO BE u, z a z o z cc o 0_ co co W Z `z 0 6 CU 0 < O Q c it L Q DETERMINED IN THE FIELD BY THE INSTALLING CONTRACTOR TO SUIT CONDITIONS. ALL CHANGES SHALL BE CLEARLY INDICATED ON RISER NOTES: cn ¢ j c �„ z o 0 a I- > y THE RECORD DRAWINGS. cn cn w w 0 0 cn 00 J o 0 ,,, 00 2. SHOULD ANY CONDITIONS EXIST THAT DIFFER FROM WHAT IS INDICATED ON THESE DRAWINGS WHICH CAUSE MAJOR DEVIATIONS IN 1. RISER IS A DIAGRAMMATICAL REPRESENTATION OF THE SYSTEM ai m < a `" ¢ co w a re zcn > Lu THE WORK SHOWN,THE CONTRACTOR SHALL CONTACT JOHNSON CONTROLS IN A TIMELY MANNER SO AS NOT TO IMPAIR THE ARCHITECTURE IN BUILDING CROSS SECTION.IT IS NOT INTENDED TO a � el- ce o I- w W Z 0 Z5 0 LI a -w-� T °- -' w c� ¢ CONSTRUCTION SCHEDULE. REPRESENT ACTUAL WIRE RUNS,PANEL CONFIGURATIONS OR z a u ce m m 0 C > w a I- w CO r4 v z } o d > z a ¢ W O z o H ...c>' z � 3. CONTRACTOR IS RESPONSIBLE FOR MAKING AND OBTAINING APPROVAL FOR ALL NECESSARY ADJUSTMENTS IN CIRCUITING AS PENETRATIONS.REFER TO FLOOR PLANS AND PANEL DETAILS FOR REQUIRED TO ACCOMMODATE THE RELOCATION OF EQUIPMENT AND/OR DEVICES WHICH ARE AFFECTED BY ANY AUTHORIZED CHANGE. CIRCUIT ROUTING AND CONFIGURATION INFORMATION. _1 _i = a re U. Z w 0 ~ ca ¢ 0 ¢ 0 ¢ ¢ ¢ ¢ w w o r a ALL CHANGES SHALL BE CLEARLY INDICATED ON THE RECORD DRAWINGS. 2. ALL WIRING SHALL COMPLY WITH APPLICABLE ELECTRICAL CODES. 0 1_ 1_ 1_ co 0 I-. tr fr ,- 4. A STAMPED SET OF APPROVED FIRE ALARM DRAWINGS SHALL BE AT THE JOB SITE AND SHALL BE USED FOR INSTALLATION. REFER TO'APPLICABLE CODES&STANDARDS ON SHEET FA 001 FOR ¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢ cn CO CO c> q ct ¢ ¢ ¢ w V) � 0w 5. THE POWER CIRCUIT TO THE FACP AND TO THE FIRE ALARM POWER SUPPLIES SHALL BE ON A DEDICATED 120V,20A BRANCH CIRCUIT SPECIFIC CODE REFERENCES. I- F- F- F- F- F- F- z z z 0 J z > > LLJ z CO BREAKER,AND SHALL HAVE A RED MARKING,LOCK-ON PROVISION AND SHALL BE IDENTIFIED AS"FIRE ALARM CIRCUIT CONTROL.' THE 3. DEVICES ARE TYPICAL.SEE FLOOR PLAN FOR QUANTITY&LOCATIONS. ¢ ¢ < ¢ a ¢ a a < a I- 1- C -74 t¢ w w a � a a Y LOCATION OF THE CIRCUIT DISCONNECT MEANS(CIRCUIT BREAKER)SHALL BE PERMANENTLY IDENTIFIED AT THE FIRE ALARM CONTROL 4. EXISTING DEVICES SHOWN SHADED FOR REFERENCE. NEW AND CTRL UNIT ANNUNCIATION NOTIFICATION FIRE SAFETY CONTROL 0 UNIT. RELOCATED DEVICES ARE SHOWN BOLD. SYSTEM INPUTS ABCDEF GH I JK LIANOPQR S T UVWX Y o 6. UPDATE THE AS-BUILT DRAWING SET DAILY WITH JOB PROGRESS. RETURN THE AS-BUILT DRAWING SET TO JOHNSON CONTROLS NO I 1 SMOKE SENSOR/DETECTOR X X X X X XX X X X X X X u LATER THAN 7 DAYS AFTER FINAL TEST. V 7. THE CONTRACTOR WILL MAINTAIN ALL AREAS OF THE BUILDING IN A NEAT AND WORKMANLIKE MANNER. 1 N83 12 MANUAL PULL STATION X X X X X X X X 8. DO NOT APPLY POWER EXCEPT IN THE PRESENCE OF A FACTORY TRAINED JOHNSON CONTROLS TECHNICAL REPRESENTATIVE. 3 DUCT SENSOFJDETECTOR-SUPERVISORY X X X X X X X a 0- 9. ANY SMOKE DETECTOR HEAD INSTALLED BEFORE THE BUILDING IS CLEANED AND ACCEPTED SHALL BE COVERED TO PROTECT FROM 4 MAIN FLR.ELEV.LOBBY SMOKE DETECTOR X X X X X X X X X X X X X X X o DUST. ANY FALSE ALARMS DUE TO DIRT CONTAMINATED HEADS SHALL BE THE RESPONSIBILITY OF THE FIRE ALARM INSTALLER. 5 I ELEVATOR LOBBY SMOKE DETECTORS(EXC.MAIN FCR) X I X X X X X X X X X X X X X X Ili Y 10. THE FIRE ALARM INSTALLER WILL MAINTAIN THE FIRE RESISTANCE INTEGRITY OF ALL WALL,CEILING,AND ROOF ASSEMBLIES ANY TIME 4100 6 ELEVATOR MECH.ROOM HEAT DETECTOR X x I I x x x I x x x x x m ce N THAT WORK IS NOT ACTIVELY BEING PERFORMED. co �' 11. INSTALLATION OF DEVICES SHALL BE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. POWER LIMITED AND NON-POWER TPR4 7 ELEVATOR MECH.ROOM SMOKE DETECTOR X X I X X X I x x x x x X X X X X � LIMITED FIELD WIRING MUST BE INSTALLED WITHIN THE FACP ENCLOSURE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND 8 ELEVATOR SHAFT HEAT DETECTOR X X X X X X X X X X a APPLICABLE ELECTRICAL CODES.REFER TO'APPLICABLE CODES&STANDARDS'FOR SPECIFIC CODE REFERENCES. 11TH FLOOR, I ///;120 VOLT AC 9 ELEVATOR SHAFT SMOKE DETECTOR X X X X X X X X X X X X X X X w 12. ALL WIRING SHALL BE INSTALLED ACCORDING TO APPLICABLE ELECTRICAL CODES. ELEC ROOM 10 ELEVATOR POWER MONITOR X X X X X X z 13. FIRE ALARM CIRCUITS SHALL BE IDENTIFIED IN ACCORDANCE WITH APPLICABLE ELECTRICAL CODES. MARK ALL FIRE ALARM WIRES IN 11TH FLOOR 11 WATERFLOW SWITCH X X X X X X X X X X X DRAWN BY: R.HERMANT a ACCORDANCE WITH APPLICABLE ELECTRICAL CODE SECTIONS FOR POWER LIMITED AND NON-POWER LIMITED WIRE. 12 TAMPER SWITCH X X X X X X CHECKED BY: A MAZHNIKOV ro 14 FIRE ALARM CABLE INSTALLED IN DUCTS,PLENUM,AND OTHER SPACES USED FOR ENVIRONMENTAL AIR SHALL BE TYPE FPLP. ISSUE DATE: 3/17/20 15. FIRE ALARM CABLE INSTALLED IN THE VERTICAL RUNS AND PENETRATING MORE THAN ONE FLOOR OR CABLES INSTALLED IN VERTICAL 13 POST INDICATOR VALVE SWITCH X X X X X X 14 FIRE PUMP RUNNING X X x I x x x JOB#: RUNS IN SHAFTS SHALL BE TYPE FPLR. 15 FIRE PUMP POWER FROM ALTERNATE SORUCE X X X X X X PROJECT#: 448:617940201 16. FIRE ALARM CABLE INSTALLED IN UNDERGROUND CONDUIT OR OTHER WET LOCATIONS SHALL BE UL LISTED FOR WET LOCATIONS. JOHNSON CONTROLS©2020 17. FIRE ALARM CIRCUITS EXTENDING BEYOND ONE BUILDING AND RUN OUTDOORS SHALL BE INSTALLED IN ACCORDANCE APPLICABLE 16 FIRE PUMP PHASE LOSS/REVERSAL X X x � � x x x ELECTRICAL CODES,WHERE APPLICABLE. 17 GENERATOR RUNNING X X X X X x SYSTEM: 18. ALL WIRING,INCLUDING SHIELDS MUST BE DRY AND FREE OF SHORTS AND GROUNDS. ) C _L`(RL) V� 18 GENERATOR FAULT X X X x x x FIRE ALARM SYSTEM 19. ALL SHIELDED WIRE MUST HAVE SHIELD CONTINUITY AT FULL LENGTH OF THE WIRE. (1034 j\>titi 5 T JB 19 FIRE ALARM AC POWER FAILURE X X X X X 20. ONLY SYSTEM WIRING CAN BE RUN IN THE SAME CONDUIT. SHEET: 21. 120VAC IS NOT PERMITTED IN THE SAME CONDUIT WITH LOW VOLTAGE WIRING. 20 FIRE ALARM SYSTEM LOW BATTERY X X X X X 22. MAINTAIN MAXIMUM CONDUIT FILL RATIO AS PER APPLICABLE ELECTRICAL CODES REQUIREMENTS. 21 OPEN CIRCUIT OR GROUND FAULT X X X X X 23. EXISTING CONDUITS MAYBE USED BY THE INSTALLATION CONTRACTOR AS DEEMED NECESSARY;HOWEVER,ANY EXISTING CONDUIT 22 I GLASS B NOTIFICATION CIRCUIT(NAG)-SHORT I X X I X X X E WILL BE USED ONLY IF CONDUITS MEET CURRENT STANDARDS AND CODES.JOHNSON CONTROLS MAKES NO STATEMENTS WRITTEN OR COVER SHEET VERBAL AS TO THE CONDITION OF EXISTING CONDUITS. 10TH FLOOR N"' r0 ut t < IMPORTANT NOTICE TO USER:This information may not be sold or transferred to any third party,used on other projects or additions to the project for which it FA O N was prepared,or used for completion of this project by any third party. Johnson Controls disclaims all liability for the use or reuse of altered files by the user or x any third party and such use will be a user's sole risk. User shall,to the fullest extent permitted by law,defend,indemnify,and hold Johnson Controls harmless M from any and all claims for loss,damage or injury arising directly or indirectly from any such unauthorized use. 0 Johnson Controls 2020.All rights reserved.Reuse,copying,modification or alteration of the drawings and other information contained herein is strictly prohibited. s a y 7 GENERAL NOTES: 1. ALL CEILINGS ARE ASSUMED TO BE 10'A.F.F.,SMOOTH CONSTRUCTION UNLESS Class B NOTED OTHERWISE. TPR4.11TH FLOOR,ELEC ROOM•4100u XPDR VOLTAGE DROP SUMMARY Spare 2. EXISTING DEVICES SHOWN SHADED FOR REFERENCE. NEW AND RELOCATED IIIIIISII"N���� Standby Total Alarm Total Plan Circuit DEVICES ARE SHOWN BOLD Description %DropCapacico r- ty Module Qty Description Current Standby Current Alarm Circuit P Load P tY :III coo N81 10TH FLOOR. SUITE 1000 STROBES SIG81 0.454A 3.01% 84,87% I KEY NOTES: C u7 Panel Equipment N82 10TH FLOOR SUITE 1050A STROBES S1082 0.460A 2.46% 84.67% 1 in N83 10TH FLOOR,SUITE 1050 STROBES SIG83 1.5443 14.24% 3400°/n I 10 CHANGE CANDELA OF EXISTING DEVICE TO 15CD. Z 4100-9600 1 BASIC TRANSPONDER . 0.0870 0.0870 0.0870 0.0870 2.458A Total O a x CHANGE CANDELA OF EXISTING DEVICE TO 30CD. 0 Q cL u_ 4100-5125 1 REMOTE POWER SUPPLY W/CHARGER- 120VAC 0.1500 0.1500 0.1850 0.1850 u„ 4100-5101 1 EXPANSION PWR SUPPLY(XPS)- 120VAC 60HZ 0.0500 0.0500 0.0500 0.0500 O3 CHANGE CANDELA OF EXISTING DEVICE TO 75CD. 0 � D 4100-5005 2 ZONE MODULE, 8lDC, CLASS 8 0.0750 0.1500 0.1950 0.3900 4O CHANGE CANDELA OF EXISTING DEVICE TO 110CD. o cp 4100-3204 1 4 RELAYS-2 AMP 0.0150 0.0150 0.0600 I 0.0600 C 0 O o c, _" - N83 Distributed Load Voltage Drop 4100-1312 1 ANALOG FLEX 50W AMP W/3 CLASS B NACS 25V 0.0850 0.0850 2.2700 2.2700 U i % M 75° DEVICE MOUNTING HEIGHT REFERENCE O � w 4100-1245 1 FLEX 50 EXPANSION NAC BOARD 0.0084 0.0084 0.0600 0.0600 Allowable%Drop: 21.6% Wire Res.Per Ft. 0.003070 @ 75 Celsius Wire Gauge: 14ga Min.Device Voltage: 16.vdc ce �o 5 4100-0621 1 ANALOG AUDIO RISER MODULE 0.0150 0.0150 0.0150 0.0150 StartingVoltage: %Volta a Drop14.24% PER NFPA 72 O Y cK Panel Totals 0.5604 3.1170 g 20.4vdc 9 o I. Ckt Capacity I 3.A Notification Appliances Setting Normal Operation VISUAL APPLIANCE MOUNTING HEIGHT CONSIDERATIONS IN SLEEPING ROOMS 1. MIN DISTANCE IN SLEEPING ROOMS IS 24"(610mm)FROM CEILING TO TOP A/C SUPPLY 4009-9201 1 4009 IDNET NAC EXTENDER, 120 VAC * 0.0000 0.0000 0.0000 0.0000 Distance Device Voltage Voltage At OF LENS FOR 110CD STROBES WITHIN 16'OF THE PILLOW OR RETURN THE 4"REQUIREMENT FOR SMOKE DETECTORS HAS Device# PID Setting (Feet) Current Drop Device 2. 177CD STROBES,USED IN SLEEPING ROOMS,CAN BE WITHIN THE 24" DIFFUSER 4906-9101 1 V!0 MC NON ADDRESS,RED,WALL 110 0.0000 0.0000 0.2520 0.2520 BEEN REMOVED FROM THE 2010 EDITION OF NFPA 72 N83-1 4906-9101 15cd 41 0.060 0.389 20.01 (610mm)MINIMUM DISTANCE FROM THE CEILING.THE HIGHER INTENSITY IS 4906-9101 15 VIO MC NON-ADDRESS,RED,WALL 15 0.0000 0.0000 0.0600 0.9000 N83-2 4906-9101 15cd 20 0.060 0.571 19.83 TO COMPENSATE FOR A POSSIBLE SMOKE LAYER. 3'(914mm) 4 --NOTE:MEASUREMENTS 4906-9101 4 VIO MC NON-ADDRESS,RED,WALL 30 0.0000 0.0000 0.0940 0.3760 N83-3 4906-9101 110cd 34 0.252 0.868 19.53 ) I \I-- MINIMUM CEILING (102mm) SHOWN ARE TO THE CLOSEST N83-4 4906-9101 15cd 43 0.060 1.178 19.22 €�iiiiiiiiiiii/ilii)riiiiirhili//iiiiiiiiiiiii7r��������i���/�i���i��������������1/l///2/r/ilii/i/��//��rii��i����������������/ ///// \\\\\Wii�iriiiiiiiiiiiiri//hili rir-rir ri./rii�/hili/ ririri/// / r', EDGE OF THE DETECTOR. 4906-9101 5 VIO MC NON-ADDRESS,RED,WALL 75 0.0000 0.0000 0.1860 I 0.9300 ( -- � � --�---. N83-5 4906-9101 75cd 91 0.060 1.458 18.94 FOR CEILING HEIGHTS LESS THAN 86" i RSS-24MCW-FR 1 MULTI CD STROBE. WALL MNT, RED 110 0.0000 0.0000 0.2200 0.2200 - " --- --- NFPA 72 AUDIBLE APPLIANCE 6"MIN CEILING MOUNTEI 4" N83-6 4906-9101 75cd 40 0.060 1.716 18.68 (2180mm),THE VISUAL LENS MOUNTING (152.4mm MIN)BELO N FINISHED CEILING SMOKE/HEATAT RSS-24MCW-FR 5 MULTI CD STROBE. WALL MNT, RED 15 0.0000 0.0000 0.0600 0.3000 N83-7 4906-9101 30cd 48 0.094 2.008 18.39 HEIGHT SHALL BE WITHIN 6"(150mm)OF THE DETECTOR (102mm) RSS-24MCW-FR 2 MULTI CD STROBE, WALL MNT, RED 30 0.0000 0.0000 0.0920 0.1840 N83-8 4906-9101 30cd 13 0.094 2.080 18.32 -. CEILING. N83-9 4906.9101 75cd 88 0.186 2.514 17.89 0 ACCEPTED HERE 12"(305mm) RSS-24MCW-FR 7 MULTI CD STROBE. WALL MNT, RED 75 0.0000 0.0000 0.1650 1.1550 a ( ) f HEAT DETECTORS 1 I MAXIMUM TO TOP OF SENSOR N83-10 4906-9101 15cd 35 0.060 2.647 17.75 `F I R J F�RJ Peripheral Totals 0.0000 4.3170 N83-11 4946-9101 75cd 18 0.186 2.709 17.69 AUDIBLENISUAL4110 AUDIBLE ONLY NEVER HERE System Totals*: Standby 0.5604 Alarm 7.4340 N83-12 4906-9101 75cd 54 0.186 2.832 17.57 &VISUAL ONLY TO EXIT DOOR 1. 2-wire detector alarm current is included in the alarm current of the Initiating Device Circuit. N83-13 4906-9101 75cd 63 0.186 2.904 17.50 APPLIANCES 5'(MAX.) WALL MOUNTED 2. Backup Amplifier assumes Main Amplifier alarm current on failure. Totals: 538 Ft. 1.544A (1524mm) SMOKE/HEAT DETECTOR Standby Standby Alarm Alarm SYNCHRONIZE MORE THAN TWO APPLIANCES Battery Set#1 {Cabinet/Charger#1) Current Total Current Total IN ANY FIELD OF VIEW. MAGNETIC 5" Select ALL Power Supplies on this battery set: 96"MAX NEPA,ADA 90"0mm MAX) MIN(2286mm MIN)ABOVE FINISHED ( ) { ) DOOR 127mm XPS-1 0.4104 5.3900 ABOVE(2�N SHED FLOOR (OTHERHOLDER FLOOR MOUNTING HEIGHTS SIDE WALL RPS-2 0.1500 2.0440 ' REF.80"MIN IBC TO TOP OF LENS SHALL BE PERMITTED BY THE AHJ 0FINISHED Sub Total 0.5604 7.4340 (2032mm MIN)REF.96" PROVIDING IT MEETS THE SOUND LEVEL T DOOR WALL 80"MIN(ADA) OUTPUT REQUIRED.) WIDTH MAX(IBC)(2440mm MAX) (2032mm MIN) [STATION FIREMANUAL PULL - LESS 3"ABOVE FINISHED FLOOR 80"MIN(NEPA) Total 0.5604 7.4340 PHONE (76mm) (2032mm MIN) JACK ,. TO BOTTOM OF LENS Standby Time= 24 His x 0.5604 = 13.4496 Standby Ah NOTE:REFER TO THE PROPER DEVICE ® iiii + Alarm Time= 15 Min 0.25 x 7.434 = 1.8585 Alarm Ah INSTALLATION INSTRUCTIONS 48"MAX(ADA)(1219mm) 15.3081 FOR BACKBOX MOUNTING 48"MAX(NFPA,ADA)(1219mm MAX) Additional Spare Battery Capacity= 0% + 0.0000 HEIGHT. 42"MIN(NFPA)(1067mm MIN) 15 3081 MEASUREMENTS SHOWN ARE FINISHED TO TOP OF PULL HANDLE Battery Discharge Factor= Y0% + 3.0616 Minimum Battery Required 2081-9287 25AH(2x) 18.3697 FLOOR Battery Supplied 2081-9276 33AH{2x) *System Totals represent total system current requirements.Those currents may be distributed between multiple battery sets or power supplies as shown above. TrueAlert CONVENTIONAL APPLIANCES i, SIMPLEX 4906 SERIES WALL MOUNTED VISUAL LL Q rr 4\ 5 7 8 9 �O STANDARD ELECTRICAL a' \ BOX MOUNTING 4"SQUARE (7, ELECTRICAL BOX ( o BOX, 1 112 DEEP 0 o - CD SURFACE MOUNT 0 ADAPTER SKIRT 1 5B" • 0 0 (41mm)DEEP.CONDUIT CUTOUTS ARE PROVIDED "14-# 0�- �� ON ALL FOUR SIDES. �-- OU tomes-- _- a - fI 7 - !'--- n 1-_ --__--13 I, I I1 Ili II 11 ,,F II , 11 11 ,I----11----11-----1 �, �. SURFACE MOUNTING Ci [) - - _ _ - - - I` _ ` L ` 0 Nb I I I I I t CANDELA INTENSITY +'f +,I c I / \ �' FROM REARS BLE Iril�:a1 hI�'Ili OFFICE OFFICE OFFICE OFFICE OFFICE• cp `-111411 �` , �� c 1005 1006 1007 1008 10091 I I� HOUSING TO NEXT `N\-}------, I -, 1 DEVICE OR c \ TOP OF LENS: NAC CIRCUIT + +-1EOL Q �_ 96"(2044mm)A.F.F MAXIMUM O { ) cr , �. _ -_- (-----� (-- � RESISTOR JTFOR CEILINGS<86"(2180mm)A.F F.: TERMINATION VIEW:REAR OF DEVICE (N81) " " HALL 4- V _ \\\ BOTTOM'OF LENS:FROM CEILING CLASS B WIRING Ce p • • - ci_ ' 1 N$1 7 1OK 1013 V 1 N81 1 I 80"(2032mm)A.F.F.MINIMUM WIRING NOTES W 0 SUS 1. MAINTAIN CORRECT POLARITY ON TERMINAL --'=" OPEN MOUNTING OPTION "B" CONNECTIONS. o I I V �•� I HALLti i ' OFFICE :TO TPR41 4010 i I ---' I - 81 6 �� 1010 11TH FLOOR, 2. ALWAYS CUT CONDUCTORS AND SECURE UNDER V �. TERMINALS.NEVER LOOP WIRES UNDER O 'l' (€1, V N81-5 - ELECROOM N83) TERMINALS. m 13' _ II _ CONFEREN + _ Al _ N81 2 _ _ �_ _ - 10K /2'- ♦ 3. ANY WIRE SPLICES TO BE MADE BY LISTED AND Ce Z N 1004 a I� 30 • � AHJ APPROVED METHODS. W W N o // ,I� .� � I -� L- - 75 Z•N83 13 W SUITE 15 < V AREA OF WORK MOUNTING OPTIONS � o Ce01 N:1-4 �� WORK I ,- I OPTION DESCRIPTION NOTE Ce (' C - O 1060 ��i. i um L II o [nC I „ „ ,i i, S71 u II .. V 1012 -... .. - ____ IT I A SINGLE GANG BOX, 1 112 (64mm)DEEP BY OTHERS.WHEN SURFACE O F z RECEPTION 1011 I B 4"(102mm)SQUARE BOX, 1-1/2"(38mm)DEEP,MINIMUM MOUNTING USE 4905-9937(RED)OR V J Cn ci L < IL 4906-9940(WHITE)SKIRT 1001C 2 GANG BOX, 1-112"(38mm)DEEP o p Ce C - - - (ras r TII I- - - I - - - / I SIMPLEX 2975-9145,7-7/8"H x 5-118"W x 2-3/4"D W V < \� _ ; 5 I �/ D 127mm x 98mm x 56mm REQUIRES 4905 9931 PLATE ORDERED SEPARATELY Z N 0 I ✓ N81 3Wr ( ) .� p ..� rn _ 1 , 1. FOR ADDITIONAL MOUNTING OPTIONS,DOWNLOAD DATA SHEET 4906-0002 FROM HTTP:/IWWW.SIMPLEX-FIRE.COM marl Cn J r Li \ BREAK / o 1002 SUITE Nry .. _- _ / 1000 - -Ns E --± \ - - - -�� _ - I - J LL N82 5 -T 1020 I i (N82) 111 10K OFFICE (--- 75 "o - \.__.,..._ 1002 = - / I 1 RECEPTION I �■ I I 4 N83-12 � = 1001 1 .. V 0 0 • SUITE OPEN OFFICE 1008 I = CONFERENCE rt i 15 o _ 1050 _ _ _ I 1012 15 • AREA OF WORK I: L'M IL/ 5 i te PO • • 15 LOBBY -- STORAGE SERVER - J �� / N82-4 1001 V / N83-5 1003�{15 15 1005 MI R� 15 • 1R )I M • (RL) o 02( / OFFICE V N8 2 QUIET N$3 1 TO TPR4, 110 �` m OPEN - --- 1004 11TH HALL 1003 % A + V FLOOR ,` I - ui ri[t - - - J! ;� 1 I _ I- i #007 - _ z / SRL ��' I \ o 1004 � In_ 11 a 4. ,. _Mit 10, a o_ V •• awlp N83-3 V 0 BREAK V V COPY N83-3 LV 41 OPEN OFFICE Lu 1011 1002 ,\ 72-53. 5 CONFERENCE r \ 1006 Y \ I 1015 r \ .. ,\ N82 3• V N30 Z• ? 15 • G y - l/ / 4)_______ _ SLFI.E. - „I' • _.. _� ._.� .._._ �._ _ • 11 L - - 1005 V • 15 1 N83 4 - - -- / - I � x a (RL) cap 15 TO TPR4 N15 5 - II V 75 N83-9 F' • 11TH FLOOR, I / W / N82 1 V ELEC ROOM _I �. ara N I - ,' \ � - -)-I- .. j I o OFFICE V • 75 w Y o OFFICE 1010 CONFERS CI= (RL N83-1 1 o CONFERENCE 1009 1006 BREAK (RL) 2 1013 ? OFFICE iz-_- \ 1014E • 1012 l �I-� ,,/ 30 N$3 8 30 ' OFFICE OFFICE / 75 V z r • • • j. . II 1011 1010 N83-8 15 • DRAWN BY: R.HERMANT a \ _ RL p- 3Q N83-7( • 83-10 CHECKED BY: AZHNIKOV I�"t V ISSUE DATE: 120 OFFICE OFFICE V OFFICE 1008 = 1009 J08#: 1007 I I I I I I I PROJECT#: :617940201 JOHNSON C041:ROLS©2020 C' - IIIA •- - _ __- "...__Inn• i _ - f ; _ - - SYSTEM:FIRE ALARM SYSTEM SHEET: 10TH FLOOR DEVICE PLACEMENT PLAN, CALCS &WIRING TYPICALS °, N N 4(Alo Cn W DEVICE PLACEMENT PLAN - 10TH FLOOR -/-41 SCALE:1/8" = 1'-0" FA-101 SCALE:1/8"= 1'-0" IN FEET X 0 0 4' 8 16 ©Johnson Controls 2020.All rights reserved.Reuse,copying,modification or alteration of the drawings and other information contained herein is strictly prohibited. /, /