Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans (50)
F PS2020-00037 ,..,_, CL:,LO , LINCOLN TOWER „„..„„,„„.. 71:1114114 c,- n1/2 VD CO ap tn 00 Johnson /4( Qo Controls o , ,_ I-M 0 ciQo ow- UCI)U DRAWING INDEX LEGENDS APPLICABLE CODES & STANDARDS JOHNSON CONTROLS CONTACTS cn c,~ LOYg JURISDICTIONS WITHIN THE STATE MAY HAVE AMENDMENTS TO THE STATE ADOPTED CODE. CHECK Sales Representative Drawings Prepared By WITH THE LOCAL JURISDICTION AUTHORITY FOR MORE DETAILS. Oregon Structural Specialty Code,2019 Edition BRYAN ADAMS RON HERMANT BRYAN.ADAMS@JCI.COM RONALD.HERMANT@JCI.COM Oregon Fire Code,2019 Edition PHONE:503-683-9000 PHONE:503-683-9000 SEAN MALLON Oregon Mechanical Specialty Code,2019 Edition Scheduling Drawings Reviewed By LICENSE#5189LEA FIRE ALARM SYMBOL LEGEND Oregon Electrical Specialty Code,2017 Edition CATHRYN ANN EVERETT CATHRYN.ANN.EVERETT@JCLMARIA GERRONE COM MARIA.GERRONE@JGLCOM EXPIRES 10/01/2020 PHONE:503-683-9000 PHONE:503-683-9000 SYMBOL DESCRIPTION BRAND MODEL BACKBOXWIRE National Fire Alarm Code(NEPA 72),2016 Edition NIGET LEVEL IV #126987 Sheet List Table TYPE � Sheet Sheet Title j PANELS Number NAC6 4009 IDNET NAC EXTENDER PANEL, 120 VAC, BEIGE SIMPLEX4009-9201 SIMPLEX CABINET N/A IFA 001 COVER SHEET __._ J -. IFA-101 6TH FLOOR DEVICE PLACEMENT PLAN,WIRING TYPICALS&CALCS !INITIATING DEVICES _ 0 i ADDRESSABLE PHOTOELECTRIC SMOKE SENSOR W/STANDARD SIMPLEX 4 8"90 9714 HEAD 4"OCT, 1-1/2"D M BASE 4098-9792 BASE NOTIFICATION APPLIANCES - — --- OCCUPANCY TYPE(S): SPRINKLER PROTECTION: # CONVENTIONAL MULTI-CANDELA STROBE,WALL MOUNT,RED, SIMPLEX 4906-9101 SINGLE GANG 1-112"D V B BUSINESS GROUP BUILDING IS FULLY SPRINKLED CLEAR LENS,FIRE 10K-Wlr END-OF-LINE RESISTOR 10K(EOL) SIMPLEX 4081-9008 EXISTING DEVICES SHOWN SHADED FOR REFERENCE SCOPE OF WORK PROJECT DIRECTORY MODIFY EXISTING FIRE ALARM SYSTEM: PROVIDE NEW DEVICES,RELOCATE AND DEMO EXISTING DEVICES AS SHOWN ON DRAWINGS. Site Johnson Controls District-448 ALL NEW WIRING TO BE CLASS B. LINCOLN TOWER 10260 SW GREENBURG RD 6305 SW ROSEWOOD ST,SUITE A THE EXISTING FIRE ALARM SYSTEM SHALL NOT BE DISCONNECTED OR TAKEN OUT OF SERVICE WITHOUT WRITTEN PERMISSION FROM THE OWNER. IT TIGARD,OR 97223 LAKE OSWEGO,OR 97035 PHONE: 503-683-9000 IS THE CONTRACTOR'S RESPONSIBILITY TO COORDINATE WITH THE OWNER THE TIMING OF ANY EXISTING FIRE ALARM SYSTEM DEMOLITION WORK. FAX: 503-675-6521 SERVICE:503-683-9001 Owner Installer DESIGN STATEMENT SOR 97223IN REALTY SERVICES POINT MONITOR CORPORATION 10220 SW GREENBURG RD 5863 LAKEVIEW BLVD,STE 100 TIGARD, LAKE OSWEGO,OR 97035 Q DESIGN IS FOR FIRE ALARM NOTIFICATION OF THE OUTLINED AREA OF WORK. 0 w m E N u) N- ti `D ACCEPTABLE m CABLE TYPES 6 N FIRE ALARM WIRE LEGEND s 2 a CIRCUIT DESCRIPTION CONSTRUCTION GAUGE CIRCUIT PROPERTIES ce o_ z ce o_ z e - ABBREVIATIONS LEGEND DEVICE TAG LEGEND U w 1— 1- O C.., I- o V VISUAL 2 GOND SOLID 14 AWG X X AC = ABOVE CEILING NEC = NATIONAL ELECTRIC CODE AFF = ABOVE FINISHED FLOOR NEPA = NATIONAL FIRE PROTECTION ASSOCIATION PANEL DESIGNATOR CONDUIT SIZE MAX CONDUCTOR AREA CONDUIT SIZE Max CONDUCTOR AREA AHJ = AUTHORITY HAVING JURISDICTION NIC = NOT IN CONTRACT • FA:=FACP(NON NETWORK) v2" 0.122 5Q.INCH" 1 114" 0.598 SQ INCH' ALM = ALARM NPU = NETWORK PROCESSING UNIT • #:=NODE NUMBER 1- ANN = ANNUNCIATOR NTS = NOT TO SCALE • T#:=TRANSPONDER NUMBER 314" 0.213 SQ INCH* os14 sQ INCH• BMS = BUILDING MANAGEMENT SYSTEM PAP = PRE-ACTION PANEL • #:T#=NODE:TRANSPONDER NUMBER r 0.346 SQ INCH' 2' 1.342 5Q INCH• C = CEILING MOUNTED RC = EXISTING TO REMOVE AND COVER • NAC#:-NAC EXTENDER NUMBER J •40%CONDUIT FILL PER N.E.C. � STP=SHIELDED TWISTED PAIR CD = CANDELA RATING RD = EX€STING DEVICE TO BE RELOCATED DESIGNATOR ITEMS SUCH AS CAPACITANCE BETWEEN CONDUCTORS AND WIRE GAUGE CAN BE CRUCIAL TO THE CIRCUIT DESIGN OF THIS SYSTEM INSTALLATION. DET = DETECTOR RL = RELOCATED DEVICE CIRCUITD#=EOOR HOLDER CIRCUIT NUMBER cp U THE INSTALLING CONTRACTOR IS RESPONSIBLE FOR SELECTING AND INSTALLING CABLE MANUFACTURER AND MODEL THAT MEETS OR EXCEEDS DGP = DATA GATHERING PANEL RR = REMOVE EXISTING&REPLACE WITH NEW • THE ABOVE REQUIREMENTS.RECOMMENDED CABLE MANUFACTURERS AND MODEL NUMBERS ARE AVAILABLE UPON REQUEST. E = EXISTING TO REMAIN SCC = STATUS COMMAND CENTER • F#=FIRE PHONE CIRCUIT o EOL = END OF LINE SLC = SIGNALING LINE CIRCUIT • H#=AUDIBLE(HORN)CIRCUIT NUMBER J EPO = EMERGENCY POWER OFF SMK = SMOKE • M#=IDNET LOOP NUMBER ac FAA = FIRE ALARM ANNUNCIATOR SUPV = SUPERVISORY • P#=POWER CIRCUIT NUMBER a FACP • = FIRE ALARM CONTROL PANEL TAC = TRUEALERT ADDRESSABLE CONTROLLER • S#=SPEAKER CIRCUIT NUMBER o a_ V#=VISUAL CIRCUIT NUMBER Ce FATC = FIRE ALARM TERMINAL CABINET TRBL = TROUBLE FBO = FURNISHED BY OTHERS TS = TAMPER SWITCH •• � ca FCC •= FIRE COMMAND CENTER TYP = TYPICAL Z#=ZONE NUMBER W FSD = FIRE SMOKE DAMPER UON = UNLESS OTHERWISE NOTED FIR = FIRE ALARM TRANSPONDER VCC = VOICE COMMAND CENTER DEVICE NUMBER 0o H = HIGH HUMIDITY VT = VALVE TAMPER BRANCH I ISOLATED LOOP DESIGNATOR: O a HT = HEIGHT W = WATTAGE • (L#)= IDNET ISOLATED LOOP NUMBER Ce Lu HVAC = HEATING VENTILATION&AIR CONDITIONING W/ = WITH 1.1CO M 1-3 IMS = INFORMATION MANAGEMENT SYSTEM W/O = WITHOUT ce z N _ MAX = MAXIMUM WF = WATERFLOW w L LU MIN = MINIMUM WG = WIRE GUARD o NIA = NOT APPLICABLE WP = WEATHERPROOF r� rti 1:1-2:V12-1(L1) 03)o NAC = NOTIFICATION APPLIANCE CIRCUIT XP = EXPLOSION PROOF J CO 0 rt 0 NDU = NETWORK DISPLAY UNIT O Ce 0 z 0 SYSTEM SEQUENCE OF OPERATIONS I— o o 0 L � —�* = z N0 OF � :;f J CO ...JI o H C DC011ni'LIACE b Li /AV Law FOR O : ,5 I-- � _ :, T w _--- Ui 41 OTQ [ J ;�r �` Permit#s -rP s �.o C7I -1-C oo 3 Address X19,' 6n �.� I (dba.,�P�u'� 1 i Z GENERAL NOTES RISER DIAGRAM a z 0 O CC 1 z 1- . THESE DRAWINGS DEPICT GENERAL LOCATIONS OF LIFE SAFETY EQUIPMENT&FIELD DEVICES.EXACT ROUTING OF CONDUITS IS TO BE 0 o ¢ DETERMINED IN THE FIELD BY THE INSTALLING CONTRACTOR TO SUIT CONDITIONS. ALL CHANGES SHALL BE CLEARLY INDICATED ON RISER NOTES: to cc o U Q CO Z 0 THE RECORD DRAWINGS. CO 2. SHOULD ANY CONDITIONS EXIST THAT DIFFER FROM WHAT IS INDICATED ON THESE DRAWINGS WHICH CAUSE MAJOR DEVIATIONS IN 1. RISER ISA DIAGRAMMATICAL REPRESENTATION OF THE a v a Q Z < z ao z z - - Z 0 J Z r� w J `.L Lu a THE WORK SHOWN,THE CONTRACTOR SHALL CONTACT JOHNSON CONTROLS IN A TIMELY MANNER SO AS NOT TO IMPAIR THE SYSTEM ARCHITECTURE IN BUILDING CROSS SECTION. IT IS 0 J — cn z z o z w o v 0 U) CONSTRUCTION SCHEDULE. NOT INTENDED TO REPRESENT ACTUAL WIRE RUNS, PANEL > z w CD 3. CONTRACTOR IS RESPONSIBLE FOR MAKING AND OBTAINING APPROVAL FOR ALL NECESSARY ADJUSTMENTS IN CIRCUITING AS CONFIGURATIONS OR PENETRATIONS.REFER TO FLOOR ~ 0 z - o o - o CO Z o 0 J Cr Cr o ~ c' PLANS AND PANEL DETAILS FOR CIRCUIT ROUTING AND c) REQUIRED TO ACCOMMODATE THE RELOCATION OF EQUIPMENT AND/OR DEVICES WHICH ARE AFFECTED BY ANY AUTHORIZED CHANGE. u) w a cn J w U U O J O U O W O ALL CHANGES SHALL BE CLEARLY INDICATED ON THE RECORD DRAWINGS. CONFIGURATION INFORMATION. - EK a aW. Er 0 p w u' w I- z a 0 o CC CC w J -1 v 4. A STAMPED SET OF APPROVED FIRE ALARM DRAWINGS SHALL BEAT THE JOB SITE AND SHALL BE USED FOR INSTALLATION, 2. ALL WIRING SHALL COMPLY WITH APPLICABLE ELECTRICALo u, - J ¢ w SUPPLIES SHALL BE ON A DEDICATED 120V 20A BRANCH CIRCUIT CODES. REFER TO'APPLICABLE CODES&STANDARDS'ON ¢ Q "' Lu m J " �' it w o I W 0 a c¢_., z I < 0 5. THE POWER CIRCUIT TO THE FACP AND TO THE FIRE ALARM POWERzo J zo J zo J o o- 572 m LLJ o 5 m E o w o - - w o Q ct a o BREAKER,AND SHALL HAVE A RED MARKING,LOCK-ON PROVISION AND SHALL BE IDENTIFIED AS"FIRE ALARM CIRCUIT CONTROL." THE SHEET FA-001 FOR SPECIFIC CODE REFERENCES. 0 m 0 m 0 m o- ¢ a ¢ J o z z o M a M E 2 El d w J Z Q S- 0 u>i LU u ¢ S C7 1- c!, U7 Y LOCATION OF THE CIRCUIT DISCONNECT MEANS(CIRCUIT BREAKER)SHALL BE PERMANENTLY IDENTIFIED AT THE FIRE ALARM CONTROL 3. DEVICES ARE TYPICAL.SEE FLOOR PLAN FOR QUANTITY& a Q 0 a Q ¢ a = ¢ "' La w o CC n N _ w W w w w w w w LC) U ~ ~ ~ w O ¢ p p w w c1 UNIT. LOCATIONS. w �- ~ ~ ~ z- ~ ~ r-- Y `� J Z - CO 6. UPDATE THE AS-BUILT DRAWING SET DAILY WITH JOB PROGRESS, RETURN THE AS-BUILT DRAWING SET TO JOHNSON CONTROLS NO 4. EXISTING DEVICES SHOWN SHADED FOR REFERENCE. NEW a a ¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢ z zU) - U ¢ w < < Lo z w m ~ < > > < < < < < < Z z z 0 ui w or) LU v, 0 LATER THAN 7 DAYS AFTER FINAL TEST. AND RELOCATED DEVICES ARE SHOWN BOLD. r-- ‹ < 'C 0 I- a ¢ J J ? < w 1± r z 0 w Q a U U U U U U U U U Q` [ ¢� Z W Q J -„� w ¢ ¢ ¢ < < < < < ¢ * ZD L < ¢ w w k Z o a E 0 7 THE CONTRACTOR WILL MAINTAIN ALL AREAS OF THE BUILDING IN A NEAT AND WORKMANLIKE MANNER. CTRL UNIT ANNUNCIATION NOTIFICATION FIRE SAFETY CONTROL ,y 8. DO NOT APPLY POWER EXCEPT IN THE PRESENCE OF A FACTORY TRAINED JOHNSON CONTROLS TECHNICAL REPRESENTATIVE. SYSTEM INPUTS A B C D E F G H I J K L M N 0 P Q R S T U V W X Y a a 9. ANY SMOKE DETECTOR HEAD INSTALLED BEFORE THE BUILDING IS CLEANED AND ACCEPTED SHALL BE COVERED TO PROTECT FROM KEY NOTES: 1 SMOKE SENSOR/DETECTOR X X X X X X X X X X X 1 X X o � ° DUST. ANY FALSE ALARMS DUE TO DIRT CONTAMINATED HEADS SHALL BE THE RESPONSIBILITY OF THE FIRE ALARM INSTALLER. 2 MANUAL PULL STATION X X X X X X X X C" 10. THE FIRE ALARM INSTALLER WILL MAINTAIN THE FIRE RESISTANCE INTEGRITY OF ALL WALL,CEILING,AND ROOF ASSEMBLIES ANY TIME O EXTEND EXISTING STROBE CIRCUIT NAC6:V1 TO NEW AND V n a co THAT WORK IS NOT ACTIVELY BEING PERFORMED. RELOCATED DEVICES. RELOCATE END OF LINE RESISTOR (NAC6:V3) Am,- ---(-) -� NAC6:V3 3 DUCT SENSOR/DETECTOR-SUPERVISORY X X X X X X X Lo g a 11. INSTALLATION OF DEVICES SHALL BE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. POWER LIMITED AND NON-POWER TO LAST DEVICE ON CIRCUIT. MAINTAIN SUPERVISION. KK 4 MAIN FLR.ELEV.LOBBY SMOKE DETECTOR X X X X X X X X X X X X X XX LIMITED FIELD WIRING MUST BE INSTALLED WITHIN THE FACP ENCLOSURE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND V 7 5 ELEVATOR LOBBY SMOKE DETECTORS(EXC.MAIN FLR) X X X X X X X X X X X X X X X 6 APPLICABLE ELECTRICAL CODES. REFER TO'APPLICABLE CODES&STANDARDS'FOR SPECIFIC CODE REFERENCES. NAC6:V2)} NAC6:V2 6 ELEVATOR MECH.ROOM HEAT DETECTOR X X X X X X X X X X Lu 12. ALL WIRING SHALL BE INSTALLED ACCORDING TO APPLICABLE ELECTRICAL CODES. ( 10K 7 ELEVATOR MECH.ROOM SMOKE DETECTOR X X X X X X X X X X X X X X X DRAWN BY: R. HERMANT z 13. FIRE ALARM CIRCUITS SHALL BE IDENTIFIED IN ACCORDANCE WITH APPLICABLE ELECTRICAL CODES. MARK ALL FIRE ALARM WIRES IN E ACCORDANCE WITH APPLICABLE ELECTRICAL CODE SECTIONS FOR POWER LIMITED AND NON-POWER LIMITED WIRE. V V 8 ELEVATOR SHAFT HEAT DETECTOR X X X X X X X X X X CHECKED BY: M.GERRONE F NAC6:V1 9 ELEVATOR SHAFT SMOKE DETECTOR X X X X X X X X X X X X X X X ISSUE DATE: 3/2/20 � 14 FIRE ALARM CABLE INSTALLED IN DUCTS, PLENUM,AND OTHER SPACES USED FOR ENVIRONMENTAL AIR SHALL BE TYPE FPLP. (NAC6:V11 /y � 15. FIRE ALARM CABLE INSTALLED IN THE VERTICAL RUNS AND PENETRATING MORE THAN ONE FLOOR OR CABLES INSTALLED IN VERTICAL 1011 O 10 ELEVATOR POWER MONITOR X X X X X X JOB#: RUNS IN SHAFTS SHALL BE TYPE FPLR. (RL)} (RL) 1 111 WATERFLOW SWITCH X X X X X X X X X X X PROJECT#: 448:617582401 16. FIRE ALARM CABLE INSTALLED IN UNDERGROUND CONDUIT OR OTHER WET LOCATIONS SHALL BE UL LISTED FOR WET LOCATIONS. I 12 TAMPER SWITCH X X X X X X 17. FIRE ALARM CIRCUITS EXTENDING BEYOND ONE BUILDING AND RUN OUTDOORS SHALL BE INSTALLED IN ACCORDANCE APPLICABLE --.... - JOHNSON CONTROLS©2020 ELECTRICAL CODES,WHERE APPLICABLE (NAC6:V1) 13 POST INDICATOR VALVE SWITCH X X X X X X SYSTEM: 18. ALL WIRING, INCLUDING SHIELDS MUST BE DRY AND FREE OF SHORTS AND GROUNDS. 10r ,.___„/,___) 14 FIRE PUMP RUNNING X X X X X X FIRE ALARM SYSTEM 19. ALL SHIELDED WIRE MUST HAVE SHIELD CONTINUITY AT FULL LENGTH OF THE WIRE, 4009 115 FIRE PUMP POWER FROM ALTERNATE SORUCE X X X X X X 20. ONLY SYSTEM WIRING CAN BE RUN IN THE SAME CONDUIT. NAC6 116 FIRE PUMP PHASE LOSS/REVERSAL X X X X X X 21. 120VAC IS NOT PERMITTED IN THE SAME CONDUIT WITH LOW VOLTAGE WIRING. SHEET: M1-3 17 GENERATOR RUNNING X X X X X X 22. MAINTAIN MAXIMUM CONDUIT FILL RATIO AS PER APPLICABLE ELECTRICAL CODES REQUIREMENTS. 18 GENERATOR FAULT X X X X X X 23. EXISTING CONDUITS MAY BE USED BY THE INSTALLATION CONTRACTOR AS DEEMED NECESSARY;HOWEVER,ANY EXISTING CONDUIT LOCATED IN I �y,'i`,120 VOLT AC - X X X x WILL BE USED ONLY IF CONDUITS MEET CURRENT STANDARDS AND CODES.JOHNSON CONTROLS MAKES NO STATEMENTS WRITTEN OR 6FL ELEC ROOM 119 FIRE ALARM AC POWER FAILURE X COVER SHEET VERBAL AS TO THE CONDITION OF EXISTING CONDUITS. • 120 FIRE ALARM SYSTEM LOW BATTERY X X X X X OFFICE COPY 21 OPEN CIRCUIT OR GROUND FAULT X X X X X 0 22 CLASS B NOTIFICATION CIRCUIT(NAC)-SHORT X X X X X I U Q IMPORTANT NOTICE TO USER:This information may not be sold or transferred to any third party,used on other projects or additions to the project for which it EN was prepared,or used for completion of this project by any third party. Johnson Controls disclaims all liability for the use or reuse of altered files by the user or FA-001 X any third party and such use will be a user's sole risk. User shall,to the fullest extent permitted by law,defend,indemnify,and hold Johnson Controls harmless E, from any and all claims for loss,damage or injury arising directly or indirectly from any such unauthorized use. ©Johnson Controls 2020.All rights reserved.Reuse,copying,modification or alteration of the drawings and other information contained herein is strictly prohibited. GENERAL NOTES; 1. ALL CEILINGS ARE ASSUMED TO BE 10'A.F.F.,SMOOTH CONSTRUCTION UNLESS NOTED OTHERWISE. 1011111 2. EXISTING DEVICES SHOWN SHADED FOR REFERENCE. NEW AND RELOCATED • I c›- DEVICES DEVICES ARE SHOWN BOLDdriggialleN...7146..... 4 C--)(74 al cs? DEVICE MOUNTING HEIGHT REFERENCE END OF LINE RESISTOR CODES TrueAlert CONVENTIONAL APPLIANCES C=1 Cl PER NFPA 72 SIMPLEX 4906 SERIES CEILING MOUNTED VISUAL KEY NOTES: 0 EXTEND EXISTING STROBE CIRCUIT NAC6:V1 TO NEW AND RELOCATED ZZwX VISUAL APPLIANCE MOUNTING HEIGHT CONSIDERATIONS IN SLEEPING ROOMS !IIIIII DEVICES. MAINTAIN SUPERVISION. C0a 1. MIN DISTANCE IN SLEEPING ROOMS IS 24"(610mm)FROM CEILING TO TOP A/C SUPPLY t NOTE:REFER TO PANELIMODULE AND DEVICE le ADAPTER PLATE FOR Irji w INSTALLATION INSTRUCTIONS FOR PROPER [WIRE GUARD 02 RELOCATE END OF LINE RESISTOR TO LAST DEVICE ON CIRCUIT. MAINTAIN Q OF LENS FOR 110CD STROBES WITHIN 16'OF THE PILLOW OR RETURN THE 4"REQUIREMENT FOR SMOKE DETECTORS HAS 2, 177CD STROBES.USED IN SLEEPING ROOMS,CAN BE WITHIN THE 24" DIFFUSER BEEN REMOVED FROM THE 2010 EDITION OF NFPA 72 1- --) TERMINATIONS. u, SUPERVISION. Lo (610mm)MINIMUM DISTANCE FROM THE CEILING.THE HIGHER INTENSITY IS REFI . BAND NUMBER 1-1U -TO COMPENSATE FOR A POSSIBLE SMOKE LAYER. 3 (914mm) „ MODEL WATTS CIRCUIT TYPE FIRE ALARM PANEL/MODULENOTE:MEASUREMENTS NUMBER 3 2 3 4 5 �T BAR WITH CLIPS AND/ 4 \[ MINIMUM 102mm) ,CEILING ( SHOWNARETOTHECLOSEST 4081-9001 733-892 2.2K RED RED RED GLD N/A 112 ANNUNCIATOR(4300) 4004,4010(TROUBLE) �� SCREWSSUPPLIEDBYco�v/iiiiiii///////// ////////////iiii///////iiiiiiiiiiii///////////////////// //////// ��i /////ii ���/////ii/�ii/iiiii/iiiiiiiii// / \\\\\\r///////////�//////////////��, .////././//////////��/����/�///////�� / EDGE OF THE DETECTOR. N.O. INITIATING PULL,SMOKE, 4004',4004R,4005',4006,4100, CONTRACTOR cc in 0 4081-9002 733-893 3.3K ORG ORG RED GLD NIA I HEAT,WATERFLOW,TAMPER.ETC. 4120,4100U,ZAMs FOR CEILING HEIGHTS LESS THAN 86" ['O ELECTRICAL BOX PROVIDED NFPA 72 AUDIBLE APPLIANCE 6"MIN CEILING MOUNTED 4" 24 PT. I/OIl0 SWITCH SUPV. 4605-7401,4100 SERIES �J `f'"' BY ELECTRICAL CONTRACTOR. E2 �Cc. (2180mm),THE VISUAL LENS MOUNTING (152.4mm MIN)BELO N FINISHED CEILING SMOKE/HEAT (102mmCURRENT LIMITED N.O. INIT., 4090 IDNET IAM(EOLR) ` O 1- w cc J 4081 9003 733 89fi 4.7K YEL VT RED GLD N/A 1/2 0 a� NOTE:DO NOT BRING rn o`s HEIGHT SHALL BE WITHIN 6"(150mm)OF THE DETECTOR NOTIFICATION (DACT) 2080-9024 ri s OPTIONAL 4905-9926 a ncn 4004,4005,4090-9001 IDNET IAM, o Ito, CONDUIT THROUGH THE REAR CEILING. WIRE GUARD WITH ACCEPTED HERE 12"(305mm) 4081-9004 733-886 6.8K BLU GRY RED GLD NIA 112NIO INITIATING POLL,SMOKE, 2190 9173 MAPNETII 2 PTIIO + " OF THE ELECTRICAL BOX.j�� - HEAT,W.FLOW,TAMPER, ETC ��, MOUNTING PLATE (( F�� f �' F` f HEAT DETECTORS If I MAXIMUM TO TOP OF SENSOR 4 20MA ZAM(TROUBLE) �I F CURRENT LIMITED N.O. INITIATING _ ;�� AUDIBLENISUAL • AUDIBLE ONLY NEVER HERE 4081-9005 733-984 1.8K BRN GRY RED GLD N/A 1/2 4090-9001 IDNET IAM4%0044.140.. I MAGNETIC TEST &VISUAL ONLY TO EXIT DOOR (INLINE) 4005*,4090-9001 IDNET IAM � "I- : Ill WALL MOUNTED �` LOCATION APPLIANCES - 5'(MAX.) 4081-9006 733-890 560 GRN BLU BRN GLD N/A 1 N.C. INITIATING(EOLR) 4100,41000 I11f, � ' m, SEAN MALLON SMOKE/HEAT DETECTOR INTENSITY ;0�. �. ' :O O* (1524mm) 4081-9007 733-891 1.2K BRN RED RED GLD N/A 1 N.C. INITIATING(EOLR) 4005 = - =ate 4004.4005,4006,4008,4009,4010, , ,Tto SELECTION PLUG, _-_-_ _=-- LICENSE#5189LEA SYNCHRONIZE MORE 4081-9008 733-894 10K BRN BLK ORG GLD N/A 1/2 NOTIFICATION :m ; ACCESSIBLE ONLY + TO NEXT EXPIRES 10/01/2020 THAN TWO APPLIANCES 4100,4100U ir � STROBE MAGNETIC 5" 14081-9009 733-912 20 RED BLK BLK GLD N/A 1 TO MR-101 RELAY COIL 4005 8 POINT I/O % FROM REAR OF CIRCUIT DEVICE OR IN ANY FIELD OF VIEW. 96"MAX(NFPA,ADA) r HOUSING (-) () 10K RESISTOR op-- - - 90"MIN (2286mm MIN)ABOVE FINISHED DOOR 1 (127mm) N.C.INIT.(ACROSS CONTACTS) 4005 ,4090-9001 IDNET IAM Mir (2440mm MAX) FLOOR(OTHER MOUNTING HEIGHTS HOLDER SIDE WALL 24 PT. 110(ACROSS CONTACTS 4605-7401,4100 SERIES STROBE INTENSITY TERMINATION VIEW ABOVE FINISHED FLOOR 4081-9010 733-973 1K BRN BLK RED GLD N/A 1 CLASS B WIRING TO TOP OF LENS SHALL BE PERMITTED BY THE AHJ FINISHED CURRENT LIMITED N.O. INIT. SETTING VIEWABLE REF.80"MIN(IBC) PROVIDING IT MEETS THE SOUND LEVEL DOOR WALL- (IN SERIES WITH CONTACT) 4090-9001 IDNET IAM THROUGH THE LENS (2032mm MIN)REF.96" 80"MIN(ADA) OUTPUT REQUIRED.) WIDTH ---- - - -- °+ °° WIRING NOTES MAX(IBC)(2440mm MAX) (2032mm MIN) MANUAL PULL 14081-9011 733-974 100 BRN BLK BRN GLD N/A 1/2 ANNUNCIATOR(N2) 4006,4008,4010 MOUNTING OPTION B ABOVE FINISHED FLOOR FIRE [STATION LESS 3" 1. MAINTAIN CORRECT POLARITY ON TERMINAL $0"MIN(NFPA) PHONE (76mm) 14081-9012 733-985 22K RED RED ORG GLD NIA 112 SPEAKERCIRCUIT 4003 CONNECTIONS. (2032mm MIN) JACK 14081 9013 734-086 4.99K YEL WHT WHT BRN BRN 1/2 I 2. ALWAYS CUT CONDUCTORS AND SECURE UNDER TO BOTTOM OF LENS N.0 INITIATING(SECURITY TERMINALS. NEVER LOOP WIRES UNDER 4081-9014 734-092 2.4K RED YEL RED GLD N/A 1/2 4090-9001 IDNET IAM ® "`i" } MONITORING EOLR) TERMINALS. NOTE:REFER TO THE PROPER DEVICE ® I 4081-9015 734-093 1.5K BRN GRN RED GLD N/A 1/2 CURRENT LIMITED N.O. INIT. 4090-9001 IDNET IAM 3. ANY WIRE SPLICES TO BE MADE BY LISTED AND INSTALLATION INSTRUCTIONS 48"MAX(ADA)(1219mm) (SECURITY MONITORING EOLR) AHJ APPROVED METHODS. FOR BACKBOX MOUNTING 48"MAX(NFPA,ADA)(1219mm MAX) 4081-9016 734-149 150K BRN GRN YEL GLD NIA 1/2 MOUNTING OPTIONS HEIGHT, 42"MIN(NFPA)(1067mm MIN) 4081-9017 734-171 3.9K ORG WHT RED GLD N/A 1 OPTION' DESCRIPTION NOTE MEASUREMENTS SHOWN ARE 4081-9018 734-168 10K BRN BLK ORG GLD N/A 1 70VRMS CONSTANT SUPV.NAC 4100-1260 FINISHED TO TOP OF PULL HANDLE 378-090 8.2K GRY RED RED GLD N/A 1/2 SECURITY MONITORING(EOLR) 4100,4100U A SINGLE GANG BOX,2-1/4"(57mm)DEEP(MINIMUM) BY OTHERS FLOOR f 378-046 5.6K GRN BLU RED GLD N/A 1/2 N.O.SECURITY MON. (SERIES) 4100,4100U HANDY BOX. 1-1/2"(38mm)DEEP,OR SINGLE GANG BOX 2-1/2" 4905-9910 ADAPTER PLATE REQURED FOR SURFACE MOUNT i 378-069 12K BRN RED ORG GLD N/A 1/2 N.C.SECURITY MON.(SHUNT) 4100,4100U B (64mm)DEEP WITH HANDY BOX UNLESS USING 4905-9926 WIRE GUARD *USE WITH RETROFIT OR HIGH CURRENT MODULE 1. FOR ADDITIONAL MOUNTING OPTIONS,DOWNLOAD DATA SHEET 4906-0001 FROM HTTP://WWW.SIMPLEX-FIRE.COM NAC6 LINCOLN TOWER 6FL 4009 NAC I Standby Total Alarm Total o Module Qty Description Current Standby Current Alarm Panel Equipment 0 4009-9201 1 14009 IDNET NAC EXTENDER, 120 VAC 0 0850 0.0850 0.1850 0.1850 _ --- - _ _ Panel Totals 0.0850 0.1850 I I Notification Appliances Setting CONFERENCE m 4906-9101 4 VIO MC NON-ADDRESS,RED,WALL 110 0.0000 0.0000 0.2520 1.0080 ,- OFFICE OFFICE OFFICE OFFICE NAC6:V2-1 620 OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE 4906-9101 12 VIO MC NON-ADDRESS,RED,WALL 15 0.0000 0.0000 0.0600 0.7200 624 623 622 621 • 15 L 619 J 618 J 617 J 616 615 614 I 613 0 4906.9101 3 V/0 MC NON-ADDRESS, RED,WALL 30 0.0000 0.0000 0.0940 0.2820 - I' 1 rte... `� 4906.9101 3 V/O MC NON-ADDRESS,RED,WALL 75 0.0000 0.0000 0.1860 0.5580 I' / 1 1 Peripheral Totals (---- _ _. .• V P 0.0000 2.5680 - - .. o a e o- _ 7 z I ° n L_ ' r-_ - _ . . 0 System Totals*: Standby l 0.0850 Alarm 2.7530 NACfi:V2 5 • • • NAC6:V1-1 NAC6:V1-2 • NAC6:V2-2 , 110 75 L1 V� 110 OFFICE r o Standby Standby Alarm Alarm I 612 I \ J Battery Set#1 (Cabinet/Charger#1) Current Total Current Total °' Select ALL Power Supplies on this battery set: / V \ *\ 4009 0.0850 2.7530 +/9.110 NAG6:V2 4 OPEN 2 Sub Total 0.0850 2.7530 OFFICE / OFFICE t Total 0.0850 2.7530 NAC6;01< V -T V •• V 6 1 1 2 J 0 •• W o Standby Time= 24 Hrs x 0.0850 =2.0400 Standby Ah V 1 Ire /, Alarm Time= 15 Min 0.25 x 2.753 =0.6883 Alarm Ah � OFFICE � (' 2.7283 \ �.. S ITE - 610 / 0 0 Additional Spare Battery Capacity= 0% + 0.0000 w6 t3 2.7283 \0 • 75 co)CNI .o Battery Discharge Factor= 20% + 0.5457 \, , Q LOBBY NAC6:V1-3 N W W o Minimum Battery Required 2081-9272 6.2AH(2x) 3.2739 / = �'- . O AREA OF WORK Uj a) BatterySupplied N. FILE/SERVER OPEN �`" �- iii �, PP 2081.9272 6.2AH(2x) 61 OFFICE j T NAC6FILE STORAGE IT STORAGEOW System Totals represent total system current requirements.Those currents may be distributed between multiple battery sets or power supplies as shown above. % z _ . OFFICE --- M1-3 614 I I 613 1 ! C[r.1612 ill U I. J CO m 614 V (NAC6:V1) i L= ffJ Q Q OFFICE ROOM MELECT Of 11 10K 75/ Z • 15 CI I = oZ cv 613 NAC6:V3-8 Z i i I F7�C N rr--_;rr. _ 1 W (- • 30 v _..--- 1 -- �1 � :-.1 ,c) H �, CORRIDOR - (RL) VOLTAGE DROP SUMMARY • 15 - -3 9 f O O 617 HALL 75 • V 1- Plan 15 y 1 RECEPTION 1 616 I NAC6:V1-4 ■ T a Description Load %DropHALL }�C 15 601 Circuit p v _ O -- �- - - -_ �... - - 01? N OFFICEMIII _HU I NAC$:V1 6FL NOTIFICATION EAST SIGs 1.336A 9.28% (NAC6:V3) I 616 I -' � {- - IlL V '� u j I , .w 'I SERVER 611 ■NAC6:V2 6FL NOTIFICATION NORTH SlG2 0.fi24A 3.19 TONIIP AC6 I - 0NAC6:V3 6FL NOTIFICATION WEST 5163 0.608A 4.03% //11 OPEN v 15 616I �Mj �AC6:V4 SPARE S1G4 0.000.0 0.00% OFFICE OFFICE •• ENTRY 0pilr_T `�xJNAC6:V1 2.568A Total 618 1617 I _ 601 - NAC6:V3-1NAC6:V1-: r v • BREAK 30 -I . 15 °Ai _ Li' // OFFICE NAC6:V3-7 a - • NAC6:V3 2 ■ 7III 602 - - - OF ICE 612 _ , g � � 0 NAC6:V1 Distributed Load Voltage Drop ° WORK •. v 7 COPY/WORK _ R _ DIN BREAK 624 a Allowable%Drop: 17.9% Wire Res.Per Ft. 0.003070 @ 75°Celsius OFFICE OPEN OFFICE .. 604 w g 4g g \\ OFFICE OFFICE 622 • 601 I 602 I V - V PSS % Wire Gau e: 1 a Mi .Device Volta e: 16.vdcStarting Voltage: 19.5vdc %Voltage Drop 92870620 I 621 I NAC6:V3-3mCircuit Capacity 2.A \ v0 ISvITE 15 ( ) / o Normal0 Operation HALL RL 2 ± P I �V i P Ilfr O OPEN OFFICEw ` (NAC6:V1 NAC6:V3-5 600 602 � 1 J Distance Device Voltage Voltage At OFFICE \ 15 • 10K 606 Z PID Setting (Feet) Current Drop Device 611 A EI .• ,_ HiQDevice# - - - NAC6:V1 1 49069101 110cd 45 0.252 0.369 19.13 V • 110 O'EN OFFICE - d - O */ a NAC6:V1-2 4906-9101 75cd 60 0.186 0.768 18.73 • HALL NAC6:V3-4 NAC6:V1-9 603 / w \ V 7 d 40 0.186 0.989 18.51 \ NAC6:V3-6 v NAC6:V1 3 4906 9101 5c • I623 I • 15 v NAC6:V1-4 4906-9101 75cd 35 0.186 1.142 18.36 15 _°---° ,� �„ ._, ,L ,_�. .7j L \ ENTERTAINMENT NAC6:V1-5 4906-9101 15cd 27 0.060 1.229 18.27 \ - 609 Y 18.18H• �� NAC6:V1 7 ,j = U NAC6:V1-6 4906-9101 30cd 30 0.094 1.315 � ��15 NAC6:V1.7 4906-9101 15cd 54 0.060 1.438 18.06 \ .. I _ NAC6:V1-8 4906-9101 15cd 66 0.060 1.565 17.94 OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE � NAC6:V1-9 4906-9101 110cd 67 0.252 1.669 17.83 I 610 1 609 I 608 I 1607 I 606 605 603 I 604 - _ OFF CE OFFICE _ �riIICELu Totals: 424 Ft. 1.336A + H + H 6 i I 77- oal- 67 0 1w4. o L w a N II L__... - - a w Z DRAWN BY: R.HERMANT DEVICE PLACEMENT PLAN 6TH FLOOR CHECKED BY: M.GERRONE ISSUE DATE: 3/2/20 SCALE:1/8" = 11-0" JOB#: PROJECT#: 448:617582401 JOHNSON CONTROLS 0 2020 SYSTEM: FIRE ALARM SYSTEM SHEET: 6TH FLOOR DEVICE . PLACEMENT PLAN, WIRING TYPICALS & CALCS AtL4 in LT, U 4j SCALE:1/8"=1'-0" IN FEET FA-101 x .._ _- 0 0 4' 8' 16' ©Johnson Controls 2020.All rights reserved. Reuse,copying, modification or alteration of the drawings and other information contained herein is strictly prohibited.