Loading...
Plans (19) BU P2019-00126 4 � G 'ICED e . ,_, .. GENERAL NOTES • MA ip � i � .� gUtiLDING � 4 I THESE PLANS FOR TENANT IMPROVEMENT ONLY. 'r,;>4) ,( -V-- 2. THE PROJECT DOCUMENTS ARE OF LIMITED SCOPE, L OF O PREPARED BY THE ARCHITECT AT THE OWNER'S REQUEST i'--': .1 ��� i i~` '� TO ESTABLISH MINIMUM GUIDELINES FOR CONSTRUCTION OF THE PROJECT IN COMPLIANCE WITH THE APPLICABLE GOVERNING BUILDING CODES AND REGULATIONS. WHERE MATERIALS, ASSEMBLIES, EQUIPMENT, FIXTURES, AND SYSTEMS ARE NOT SHOWN DIAGRAMMATICALLY, IT 15 THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO CONFERENCE ROOM DETERMINE SPECIFIC LOCATIONS, PROVIDE SPECIFIC 1102 I OLP. . 15 O ,_ MATERIALS AND DETERMINE CONSTRUCTION DETAILING, 210 5F. / 15 ALL IN COMPLIANCE WITH APPLICABLE BUILDING CODES, = 14 OCCUP. 00 N REGULATIONS, AND INDUSTRY STANDARDS FOR MATERIALS 0 OPEN OFFICE OPEN OFFICE OPEN OFFICE o0 �' ' AND METHODS OF INSTALLATION. IT IS THE CONTRACTOR'S (T RESPONSIBILITY TO ASSURE THAT ALL CONSTRUCTION IS N 1 1041 OLF. • 100 1105 I OLP. • 100 1 1061 01.F. • 100 N 160 SF_ / 100 160 SF. / 100 160 S.F. / 100 Cl COMPLIANCE WITH APPLICABLE CODES AND REGULATIONS. . 2 OCCUR. • 2 OCCUP. - 2 OCCUR. 3. THE GENERAL CONTRACTOR 15 RESPONSIBLE FOR ALL Ello I : m MEANS, METHODS, TECHNIQUES AND SEQUENCES OF CONSTRUCTION INCLUDING JOB SITE SAFETY_ THE E� I O a.;ARCHITECT HAS NO RESPONSIBILITY FOR THE MEANS, METHODS, TECHNIQUES OR SEQUENCES OF CONSTRUCTION INCLUDING JOS SITE SAFETY. "Cr 4. THE WORK UNDER THIS CONTRACT/PROJECT IS TO INCLUDE — 11 1 N ALL THE LABOR, MATERIALS, TRANSPORTATION, EQUIPMENT, - — r 1 It 1 ; AND SERVICES NECESSARY FOR AND REASONABLY0 — INCIDENTAL TO THE COMPLETION OF ALL CONSTRUCTION WORK IN CONNECTION WITH THE DOCUMENTS_ -- NEW NEW DOOR ANDI WOOD RELITE ASSEMBLY 5. APPLICABLE CODES ON MATERIALS AND WORKMANSHIP FLOOR TO MATCH EXISTING SHALL CONFORM TO THE 2014 OREGON STRUCTURAL I - SPECIALTY CODE AND APPLICABLE STATE AND FEDERAL O SAFETY ORDERS. ALL REFERENCES TO CODES, _ COMMON PATH OF TRAVEL - 94'-IO" c'f3 SPECIFICATIONS, AND STANDARDS SHALL MEAN AND ARE 0\ INTENDED TO BE THE LATEST EDITION, AMENDMENT Jr — 00 AND/OR REVISION OF SUCH REFERENCE STANDARD IN IN N EFFECT. 6. EACH SUB-CONTRACTOR (OR THE GENERAL CONTRACTOR OPEN OFFICE 4 p WHEN HE 15 PERFORMING SPECIFIC PORTIONS OF THE 1103 I OLP. = 1000 1,5z3SP. / 100 WORK) IS CONSIDERED A SPECIALIST IN HIS RESPECTIVE RECEPTION = 16, OCCUR. III FIELD AND SHALL, PRIOR TO PERFORMANCE OF WORK, 1 101 10LF. = 100 NOTIFY THE GENERAL CONTRACTOR AND ARCHITECT OF rot SF./ 100 ANY WORK CALLED OUT ON THE DRAWINGS IN HIS TRADE --" I OCCUP. VALIDITY OF PERMIT THAT CANNOT BE FULLY GUARANTEED OR THAT DOES NOT WAITING MEET CURRENT LOCAL BUILDING CODES. 11001 OLP. _ THE ISSUANCE OF A PERMIT 1. THE CONTRACTOR SHALL VERIFY AND CONFIRM ALL 51 sF. /1 REMOVE UPPER BASED ON CONSTRUCTION = e OCCUP. DIMENSIONS AND CONDITIONS SHOWN OR IMPLIED ON THE AND LOWER CABINET DOCUMENTS AND OTHER DRAWINGS AND SPECIFICATIONS AS WELL AS THE DATA SHALL NOT PREVENT7HE CODE OFFICIAL FROM PHYSICAL CONDITIONS OF THE SITE NOTIFY THE " ARCHITECT OF DISCREPANCIES PRIOR TO START OF WORK r — — — _7 REQUIRING THE CORRECTION S. DIMENSIONS ARE FROM FACE OF FINISH MATERIAL El — OF ERRORS. OSSC 105.4 I I 5_ PATCH AND REPAIR ALL EXISTING WORK DAMAGED BY NEW WORK TO EXISTING CONDITION OR NEW CONDITION, J H WHICHEVER IS APPROPRIATE Qi 10, EACH SUB-CONTRACTOR MUST REFER TO DIAGRAMMATIC PLANS AND SECTIONS AND MUST COORDINATE THEIR WORK 0 N WITH ALL TRADES TO AVOID CONFLICTS, Q I— . 11, DOOR HARDWARE SHALL MEET THE REQUIREMENTS OF I H w SECTION 1004.3 - OREGON STRUCTURAL SPECIALTY CODE • Z H U 01 AND SHALL BE EITHER A LEVER OR PANIC TYPE WORK REQUIRING ONLY A SINGLE MOTION TO OPEN_ KEY-LOCKING 1108 ROOM NEW WOWOOD 1� W Ems-+ Z z0 HARDWARE MAY BE USED ON THE MAIN DOOR OF 5, F, M CREAK _ I _ W 1) Q+ 1.0 l� OR 5 OCCUPANCIES ONLY, WITH THE UNLOCKED DOOR 1101 I I Q ,�/ } llA FREE TO SWING WITHOUT OPERATION OF ANY LATCHING 4 e% Q IX DEVICE AND A READILY VISIBLE: DURABLE SIGN POSTED ^ ON THE EGRESS SIDE IMMEDIATELY ABOVE THE DOOR I Fmn O STATING "THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING _ 15 OCCUPIED". THE SIGN SHALL BE IN LETTERS I" HIGH ON F. w N n P - 0 r IY CONTRASTING BACKGROUND. 0/ 12. PROVIDE TEMPERED GLAZING AT WINDOWS 4 RELIGHTS I- — z I-+M U 2 0 PER SECTION 2406 - OREGON STRUCTURAL SPECIALTY CODE. TOP OF RELIGHT FRAMES TO MATCH TOP OF DOOR Z m FRAMES. r ' CI rl c{1 13. VERIFY KEYING REQUIREMENTS WITH TENANT AND LANDLORD_ . 14,PROVIDE FIRE EXTINGUISHERS A5 DIRECTED BY FIRE MARSHALL AT WALK-THROUGH. 15.MECHANICAL, ELECTRICAL AND PLUMBING BY SEPARATE PERMITS. 11.J 1, 1 C T FLOOR PLAN 16.WOOD FLOOR TO CARPET TRANSITION TO COMPLY WITH ', 1/4" = 1'-0" SECTION 303 OR ICC Al11.1-2009 O -14-1e LEGEND SCOPE OF WORK ADD 1 PRIVATE OFFICE WITHIN EXISTING OPEN-OFFICE EXISTING WALL TO REMAIN AREA_ REMOVE CABINETS" INSTALL WOOD FLOORS. —Nt— AREA OF III NEW WALL - 3i" METAL STUDS 57 F rri 7 _ _ _ WORK 24" O.G. %%s" GYP. BD. EACH SIDE CODE SUMMARY r - E"5" j j I GENERAL BUILDING DESCRIPTION; GENERAL OFFICE 39"-41" — / NUMBER OF STORIES: 2 { — EXISTING DOOR TO REMAIN FIRE SPRINKLERS; 100% COVERAGE c• • IP / Ap BUILDING SIZE: 45,000 SF.± — - 7 OCCUPANCY: 5 Zo - CONSTRUCTION TYPE; III-B U �j 1 TENANT SPACE SIZE; 3,555 R.SF.f ID . _ -) IIS NEW OR RELOCATED DOOR TOTAL OCCUPANT LOAD = 45 OCCUPANTS ) 3'-0"x8'-O" LION.. IIIA A $01 ° / dif : Ill " BARRIER REMOVAL THIS PROJECT ► H/� _-- EXISTING DUPLEX ELECTRICAL OUTLET TO REMAIN PERMIT VALUATION s3,80fa ) (AAA _ A _ E S � _ II of A 25% $950 Me } EXISTING EGRESS NEW DUPLEX ELECTRICAL OUTLET BARRIER REMOVAL *300 SIDE WALL PROVIDE VERTICAL LIGHTING WITH BOTTOM OF COVER PLATE TO BE AT -INSTALL NEW VERTICAL GRAS BARS GRAB BAR. SEE DETAIL 1 ~ — A ° BA TTERY P cAL BACK-UP 15" AFF_ (LION_) 1/A-I ��I ►� E EXISTING MUDRING AND PULL WIRE NO OTHER BARRIERS TO OUR KNOWLEDGE 1 VERTICAL GRAB BAR TO BE REMAIN 3,8=1 _m„ / EXISTING ILLUMINATED NEW MUDRING AND PULL WIRE FOR TENANT PROVIDED PHONE AND DATA OFFICE COSY SBA *19034 I EXIT SIGNS BATTERRY BACK-UP E.s�l (TYPICAL) T WIRING. BOTTOM OF COVER PLATE TO CITY OF TIGARD L11 _1J SE AT 15" AFF_ (WON_) REVIEWED FOR CODE COMPLIANCE Approved: J OTC: �.1 j Alk 1ST FLOOR KEY PLAN - Permit#. P/ Prkii -/f6/2 NOT TO SCALE Address: O'' . s 7,4 A V II. Suite#: cooA - 1 Date: ..5.- j a- 1 q . . OF 2 OD AR04, -I; 11 1F- 1; IC f: I C 7F.r YQ G� 1 iliii X X : / j,. _44,6 4) OF W X --- 11-1: Fi if-I: :i i~` - M • X 00 N CA cc \ / aire ,_, ----- 0 0 0 S. •-2 0 / ‘:C1,-.) P. --- --- --\ --- --- -_- . 0 --- w --- ` r n-IU 16 rhi , 5.1:)_ EMI IIP. ! Cd I-I-1-Ic° —_ Lu_1 L \/ X o , MN ——— I, S.D. `. r., 0E5 ° P.:- 0Cl;\ --_ — 0000 0 iCN so 0 � • 0 ri X _____ El W 0 i �' w cf, zo // yp � w --- --- M --- 0 z x 4 X § a FL, ei � � xza p ° r .4 Z �' U Z mN E..* N D a REFLECTED CEILING PLAN l,4" = 1'-0" LEGEND PROVIDE SOLID BLOCKING BETWEEN TOP PLATE OF JOISTS. FASTEN IML_ STUD BRACING TO BLOCKING EXISTING HVAC RETURN USING (4) "8 SHEET METAL SCREWS 05-14-19 // - / 20 GA. 3545" METAL STUD BRACING TO EXISTING HVAC DIFFUSER ' ' iROOF STRUCTURE AT 6'-0" O.C. / /� ALTERNATING DIRECTIONS. FASTEN � 4 / BRACE TO TOP OF STUD W/(2) 1*8 1 , i i i I I ! ...les N., i i � i i i i i i i SHEET METAL SCREWS AT EACH END. 1 EXISTING 2X4 FLUORESCENT FIXTURE TO REMAIN j`‘T . BRACING TO BE PROVIDED WHERE *` DISTANCE BETWEEN PERPENDICULAR L 1-1-1�� rl INTERSECTING WALLS OR HORIZONTAL EXISTING 2X4 FLUORESCENT BRACING BETWEEN WALLS EXCEEDS C L CID] FIXTURE TO BE REMOVED SUSPENDED CEILING \�� RELOCATED 2X4 FLUORESCENT FIXTURE IATTACH BRACE DIRECTLY EXISTING ILLUMINATED EXIT SIGN ,� ES_ TO STUD_ Q WITH BATTERY BACK-UP TO REMAIN T Irk 4— S.D. 5fs" GYP. BD. EA. SIDE O EXISTING SMOKE DETECTOR 7. 1 I I r ::17 " 25 GA METAL NOTE: HVAC DIFFUSERS d RETURNS SHOWN STUD AT 2'-0" O.C_ ONLY IN EXISTING LOCATIONS FOR CONTRACTORS CONVENIENCE_ , DIFFUSERS AND RETURNS TO SATISFY i BOTTOM TRACK TO FINISH BUILDING, MECHANICAL AND FIRE CODE FLOOR W/HILTI 'X-U' OJ51" 0 X 34" ' + EMBED 1016" CC. CONCRETE SLAB. 015A *19034 eeI 1 1 WALL DETAIL A - 2 1,/2".I'-O" A. 2 OF 2