Loading...
Plans (3) BU P2019-00004 SW IRVING ST. 'r � MI L.Thil- . RECEIVED JAN 9 2019 \, CITY OF i IGARD 3UILDING DIVISION Architecture Interiors ` Planning Engineering sA.el? in TRIANGLE III , , ,,,,,,, .-:, 1 i _....,...„„,..i..i.,....,,,.,.,,,, _ fi„, , '` Portland, OR J i � TRIANGLE -k-d54. 503.224.9560 I r :__ '. CORPORATE VALIDI >f' OF PERMIT Vancouver,WA I it f BUIRLDING III TENANT IMPROVEMENT THE ISSUANCE OF A PERMIT 7a : BASED ON CONSTRUCTION 360.695.7879 I. I SUITE 401 DOCUMENTS AND OTHERSeattle,WA `� - w TDHE OFFTA SHALL FIICIAAL FROM 206.749.9993 ` www.mcknze.com r REQUIRING THE CORRECTION t 13221 Sw 68TH PARKWAY OF ERRORS.OSSC 105.4 MACKENZIE _ _4 DESIGN DRIVEN I CLIENT FOCUSED 1r TIGARD OREGON Client • CBRE CB RICHARD ELLIS ‘110 1 VICINITY MAP CODE SUMMARY LEGEND INDEX OF DRAWINGS gli 0.0 NOT TO SCALE GENERAL Project EXIT EXIT ACCESS G0.01 TITLE SHEET, CODE SUMMARY, AND GENERAL NOTES SUITE 401 ` ARCHITECTURAL TENANT IMPROVEMENT ____>„----...„ ''� FIRE EXTINGUISHER LOCATION -- - _. A0.01 ARCHITECTURAL GENERAL NOTES, LEGEND, AN - — ---- ,i, -;..�� 3=� I - - ' - LW . A1.10 DEMOLITION PLAN, FLOOR PLAN AND DOOR SCHEDULE AL DETAILS ❑ l 1 I NOT IN SCOPE A1.20 REFLECTED CEILING PLAN, ELEVATIONS AND FINISH SCHEDULE l .. . ..r •• • 1. —i7 .. . :.:.:...:...: :. . . ' •' . ... C A5.20 INTERIOR DETAILS TRIANGLE III - ...1-.'.-.- 1.-.....}.....4.......- 1 `� t 'I I -r'�" ! ACCESSIBLE MEANS OF EGRESES 13221 SE 68TH PARKWAY .h.-r.1.:_..:.:.r.'-....e..T lJ II . .. T1GARD, OREGON II I . .. 1• }. •. 1 — — TRAVEL DISTANCE 300s-0" MAX. (TABLE 1016.1) SCOPE OF WORK 97223 (7121 i LE -._ .. _ ' „J :::' "" I� A 30'-1" THE SCOPE OF WORK FOR THE PROJECT INCLUDES INTERIOR TENANT IMPROVEMENTS OF r APPROXIMATELY 1,787 SQUARE FEET ON THE FOURTH FLOOR. WORK TO INCLUDE DEMOLITION, NEW''�' 13� I . . , , ,Ito ,,•,, sf1 r-1-1-01 I I WALLS, CEILING, DOORS, RELITES AND FINISHES. 4 i i i I ,� �: _• . 1 I i r�� / I' I I ' — _1 VALUATION: $00,000 ,�J 3041 f� IIIh I I I I I .� `y:...:. _ Id f .. . .. . . _(__, m m ,_ i ff . 1 1 . . A A ("-- r-1 I 1 �' • • • • •.'.'.'.' I • wig -3 • tilA'ORT D, OREGON N ,� I I �, DESIGN/CODE DATA �� N I LI Lrif • 11 . . . . . . I v... • • -. 1 1 GOVERNING CODE: 2014 OREGON STRUCTURAL SPECIALTY CODE OF o .� i � I OCCUPANCY: B ,c-. 4 N .•. . . .. . CONSTRUCTION TYPE: TYPE 1-B y. . . . . . . . . . . . , I TENANT AREA: APPROXIMATELY 1,787 SQUARE FEET MACKENZIE 2018 - t d >� ! T .. . `�j l '� I( OCCUPANCY LOAD: 18 ALL RIGHTS RESERVED V_ :V ; In 1 THESE DRAWINGS ARE THE PROPERTY -- ------ r- . _ - - ----- —� `-' 1 REQUIRED DCII, 1 EXIT PROVIDED. OF MACKENZIE AND ARE NOT TO BE ��,; USED OR REPRODUCED IN ANY MANNER, ALL EXITS ARE EXISTING AND HAVE APPROPRIATE EXIT SIGNAGE. WITHOUT PRIOR WRITTEN PERMISSION BUILDING IS FULLY SPRINKLED AND HAS NFPA SMOKE DETECTION WITH ON SITE EMERGENCY REVISIONS: GENERATOR FOR FIRE/LIFE/SAFETY BACKUP POWER. AlCODE SUMMARY PLAN Z ir,Q REVISIONS REVISION DELTA THIS CLOSING DATE 4110.0 4TH FLOOR NTS fr LL"a SHEET DEFERRED SUBMITTAL SYMBOLS AND REFERENCES 2014 OSSC SECTION W6.3.4.2 (by separate permit) ,1 FIRE SPRINKLER ALARPROJECT GENERAL NOTES el PROJECT NORTH MECHANICAL . lir TRUE NORTH ELECTRICAL A. THE DRAWINGS LOCATE PRODUCTS, SURFACES, AND MATERIALS AND THE NOTES CONVEY DESIGN INTENT. THE PROJECT INTENT IS TO PROVIDE FORA COMPLETE, WORKING SYSTEM. PLUMBING FILLED ARROW I B. ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO THE LATEST ADOPTED BUILDING CODE EDITION, AND TO CONDITIONS AND SPECIFICATIONS OF ALL GOVERNING AUTHORITIES, A NOTE: DESIGN BUILDERS FOR FP. ARE FULLY RESPONSIBLE FOR THE DESIGN OF THESE . DETAIL# SYSTEMS/COMPONENTS. THESE SYSTEMS/COMPONENTS SHOWN ON DOCUMENTS ARE SCHEMATIC C. VERIFY AND CONFIRM ALL CONDITIONS, DIMENSIONS,AND LAYOUT INFORMATION PRIOR TO START OF CONSTRUCTION. NOTIFY MACKENZIE OF ANY DISCREPANCIES PRIOR TO START OF WORK.ANY INTERIOR ELEVATION ONLY: THEY ARE NOT INTENDED TO REPRESENT FINAL/CODE COMPLIANT DESIGN. PROVIDE DESIGN CORRECTION WORK REQUIRED AS A RESULT OF NOT REPORTING SUCH DISCREPANCIES SHALL BE PERFORMED AT NO ADDITIONAL COST TO THE OWNER. KEY MARK W SHEET# DOCUMENT SUBMITTAL TO ARCHITECT OF RECORD FOR REVIEW PRIOR TO SUBMITTAL SHEET TITLE: SIIB-CATEGORY TITLE SHEET, D. CONTRACTOR AND SUBCONTRACTORS SHALL CAREFULLY EXAMINE THE SITE AND THE CONSTRUCTION DOCUMENTS OF THE ENTIRE WORK. INCONSISTENCIES IN THE PLANS OR SPECIFICATIONS CATEGORY CODE SUMMARY, SHALL BE CALLED TO THE ATTENTION OF MACKENZIE. E. REFER TO ENLARGED PLANS AND ELEVATIONS WHERE INDICATED FOR ADDITIONAL INFORMATION. ENLARGED PLANS TAKE PRECEDENCE OVER PLANS OF SMALLER SCALE, AND DETAILS TAKE0 CONTACTS AND GENERAL PRECEDENCE OVER PLANS. IN THE CASE OF A CONFLICT, THE HIGHEST COST OPTION SHOULD BE PRICED. KEYNOTE SPACE NAME NOTES F. DETAIL REFERENCES SHALL BE APPLIED TO ALL INSTANCES WHERE THE SAME CONDITIONS OCCUR, UNLESS NOTED OTHERWISE. OFFICE✓ SPACE# ARCHITECT ROOM/SPACE IDENTIFICATION 114 G. THE TERMS "ABOVE FINISH FLOOR" (AFF) AND "FINISH FLOOR ELEVATION" (FFE) REFER TO FINAL FINISHED FLOOR ELEVATION, WHETHER BUILT-UP SLAB, COMPOSITE DECK, OR RAISED ACCESS FLOOR. EXIST. FLOOR FINISH MACKENZIE OFFICE COPY P RB H. DO NOT SCALE DRAWINGS. WALL BASE FINISH 1515 SE WATER AVE, SUITE 100 CITY OF TIGARD WALL FINISH PORTLAND, OR 97214 REVIEW ED FOR COOL COMPLIANCE I. CUTTING AND DRILLING OF STRUCTURAL MEMBERS NOT DETAILED REQUIRES THE WRITTEN PERMISSION OF THE STRUCTURAL ENGINEER OF RECORD. DRAWN BY: BL J. SAVE AND RECYCLE DEMOLITION DEBRIS AS APPLICABLE. ALL DEMOLISHED OR REMOVED EXISTING MATERIAL SHALL BE LEGALLY DISPOSED. COORDINATE WITH CITY OF LAKE OSWEGO CONTACT: DINA RADZWILLOWICZ Approved. ] REQUIREMENTS FOR RECYCLING/RE-USE OF DEMOLITION DEBRIS. DOOR SYMBOL NUMBER 101A TEL: 503.224.9560OT'C; ] CHECKED BY: DMR / PPA FAX: 503.228.1285 K. THE CONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE RESULTING FROM THEIR WORK. THE CONTRACTOR WILL COORDINATE CLEAN UP OF ALL AREAS AFFECTED BY DUST OR ANY MATERIALS, BOTH EMAIL: dmr@mcknze.com OTC:Permt #: � AE� _ l/� SHEET: REVISION # �� DURING CONSTRUCTION AND UPON COMPLETION OF THE PROJECT, INCLUDING THE INSIDE OF ALL WINDOWS AS NECESSARY SO THAT THE SPACE IS READY FOR OCCUPANCY BY TENANT. REVISION MARK Address: aa •S >.r lr,cl�T rl f7K l) LANDLORD J-1f Suite #: 1 L. ALL DESIGN-BUILD ITEMS, SYSTEMS,AND ELEMENTS ARE TO BE SUBMITTED FOR REVIEW AND APPROVED BY MACKENZIE. ) Q By: -÷4, Date: IIGO.01 M. EXISTING MATERIAL NOTED TO BE RETURNED TO THE OWNER SHALL BE SAFELY STORED AND PROTECTED UNTIL IT IS REMOVED FROM THE SITE BY THE OWNER. CONTRACTOR SHALL COORDINATE REVISION CLOUD CB RICHARD ELLIS A fOVeCS plans WITH THE OWNER. 1420 5TH AVENUE, SUITE 1700 pp SEATTLE,WASHINGTON 98101 shall be on job site. , JOB N42080243.44 CONTACT: CARRIE GRIFFITHS CITY OF TIGARD TEL: 206.292.6023 , FAX: carrie.griffiths@cbre.com Approved by Planning PERMIT SET: 01/03/2019 Date: H111 1 208024344\4JRAWINcs\ARCHITECTURAL\GO—o1.DWG BL 12/18/18 14:44 1:96.00 Initials: j(. ARCHITECTURAL GENERAL NOTES A. REFERENCE DOOR SCHEDULE FOR DOOR TYPE DESIGNATION AND ADDITIONAL INFORMATION. •` \ B. SEE CODE ANALYSIS PLANS FOR FIRE EXTINGUISHER LOCATIONS. Z Z Nc C. PROVIDE BLOCKING AS REQUIRED ADJACENT TO FIRE EXTINGUISHERS FOR OWNER INSTALLED AED STATIONS I o a �: 3B" MIN \m¢Li . z D. CONTRACTOR TO COORDINATE WALL MOUNTED FURNITURE, INCLUDING BUT NOT LIMITED TO, CABINETRY, Architecture ■ Interiors 18 " Z PROJECTION SCREENS,WHITE BOARDS,TELEVISIONS, ETC.AND PROVIDE NECESSARY BLOCKING AS c4 1 ,e =0 22 12" `D m / co `-. 12 3: 42" MI4 ¢d ,i' MINS '� REQUIRED. Planning Engineering Q m t 'IF BOTH LATCH 'IF BOTH LATCH AND CLOSER AND CLOSER E. CONTRACTOR SHALL COORDINATE DELIVERY AND INSTALLATION OF OWNER FURNISHED EQUIPMENT WITH I THE OWNER. F. ALL DIMENSIONS TO FACE WALL, UNLESS OTHERWISE NOTED. .___,) , G. ALIGN. FINISHES WHERE INDICATED. H. WALL THICKNESSES ARE NOMINAL UNLESS OTHERWISE NOTED. Portland, OR503.224.9560 HINGE SIDE APPROACH FRONT APPROACH I. DIMENSIONS MARKED "CLR"ARE FROM FINISH SURFACE TO FINISH SURFACE. DIMENSIONS WITH THIS MARK Vancouver, WA TAKE PRIORITY OVER ADJACENT DIMENSIONS. DIMENSIONS ADJACENT TO LATCH SIDE OF DOORS INDICATE 360.695.7879 Jrce REQUIRED CLEARANCES BETWEEN CLEAR DOOR OPENING AND ADJACENT FINISH. Seattle, WA Lu p o W 206.749.9993 J. ALL DIMENSIONS SHOWN AS PLUS/MINUS (+/-)ARE FOR GENERAL LAYOUT AND REFERENCE ONLY. U S 24., :; (-)5 I24" K. DOORS NOT DIMENSIONED ARE TO BE LOCATED 4" FROM FACE OF WALL TO OUTSIDE EDGE OF JAMB. www.mcknze.com `t a MINa ' t 1' L. ELECTRICAL/DATA OUTLETS SHOWN FOR REFERENCE ONLY. DESIGN-BUILD ELECTRICIAN TO CONFIRM ALL - MACKENZIE �� ♦ dam LOCATIONS AND REQUIREMENTS PRIOR TO START OF CONSTRUCTION. I ♦ DESIGN DRIVEN I CLIENT FOCUSED M. ALL ELECTRICAL OUTLETS TO BE WHITE, UNLESS NOTED OTHERWISE. ' o Client ZZ N. ALL ELECTRICAL OUTLETS TO MATCH BUILDING STANDARD, UNLESS NOTED OTHERWISE. < Q 0. COORDINATE AND REFER TO MECHANICAL AND ELECTRICAL DISCIPLINES FOR SPECIFIC INFORMATION, Lu LOCATIONS, DIMENSIONS, CONNECTIONS,AND PENETRATIONS. LATCH SIDE APPROACH U P. SEE MEP DRAWINGS FOR ADDITIONAL INFORMATION. CBRE i: ADA DOOR CLEARANCES 0 0 Q. PATCH AND REPAIR EXISTING CONDITIONS DAMAGED BY NEW WORK TO NEW CONDITION. CB RICHARD ELLIS 0.1 1/4"=1'-O" 0 R. ALL EXISTING BUILDING ELEMENTS TO REMAIN UNLESS NOTED OTHERWISE. Q S. EXISTING STRUCTURE TO BE LEFT UNDISTURBED AND INTACT. PERFORM NO DEMOLITION THAT MAY COMPROMISE THE STRUCTURAL INTEGRITY OF THE BUILDING. T. 100%SPRINKLERS TO BE MAINTAINED THROUGHOUT IN ACCORDANCE WITH THE LATEST ADDITION OF NFPA , 13. Project U. RE-USE ALL DEMOLISHED COMPONENTS (DOORS, WINDOWS, LIGHTS, ETC) WHERE POSSIBLE. SERVICE OR SUITE 401 REPAIR TO PROVIDE "LIKE NEW"OPERATION AND APPEARANCE. TENANT IMPROVEMENT V. SALVAGE ALL DEMOLISHED COMPONENTS AS POSSIBLE. RETURN TO OWNER FOR FUTURE USE. W. REMOVE EXISTING FLOORING THROUGHOUT, PATCH, REPAIR AND PREP SUBSTRATE AS REQUIRED TO RECEIVE TRIANGLE NEW FINISHES. III X. RETAIN EXISTING FIRE EXTINGUISHERS FOR FUTURE USE. 13221 SE 68TH PARKWAY TIGARD, OREGON 97223 ,� $ D4 " ,._ 3041 .A ET:R '. LTO 111 I � � y FHC, FVC, j VIP/ jib 3 J - OR FEC • f�ORTIA • D, OREGON • c --E- ---- ARCHITECTURAL LEGEND D - 0 0 b " F °p NOT IN SCOPE O ALL MARIGHTS CKENZ[ERESERV2018 ED Z _ _ NOTE: CONFIRM WITH ELECTRICAL DRAWINGS Z L 1 , J EXISTING CONSTRUCTION TO BE DEMOLISHED THESE DRAWINGS ARE THE PROPERTY `-- OF MACKENZIE AND ARE NOT TO BE O f ALIGN FACE OF FINISH WITH FACE OF FINISH USED OR REPRODUCED IN ANY MANNER, SWITCHES AND FIRE HOSE CABINET / + WITHOUT PRIOR WRITTEN PERMISSION A NI ADA SIGNAGE B L`'- OUTLETS C * FIRE EXT. CABINET EXISTING WALL TO REMAIN 0 REVISIONS: 5 ADA MOUNTING HEIGHTS • EXISTING 1-HOUR RATED WALL TO REMAIN a rj), EXISTING 2-HOUR RATED WALL TO REMAIN '5.-._i REVISIONS REVISION DELTA 0 THIS CLOSING DATEA '''W SHEET CC• EXISTING DEMISING TO REMAIN ' I • • / l 362S125-33 METAL STUDS NEW DEMISING WALL, SEE 91A0.01 • • / (MAX 7'–O" DIAGONALLENGTH, USE WIDER ' I ® NEW WALL TO 6"ABOVE GRID, SEE 10/A0.01 I I • • / / FLANGE) BRACING TO • / 2\ / EXISTING DUPLEX OUTLET a METAL DECK AS OCCURS SOUND BATT AS , / , STRUCTURE ABOVE AT v — — / 455• 8'-0" OC W/ (2) #8 EXISTING QUADPLEX OUTLET ' ° SEE PLAN / 7 OCCURS,OSHEET METAL SCREWS AT SPAN TABLE FOR METAL STUDS" DEFLECTION SPACE FOR LOCATIONS, IF EACH END. BRACING TO EXISTING COVERPLATE 4 I I (DO NOT FASTEN STUDS APPLICABLE BE PROVIDED WHERE • Lialv OR GYP BD TO RUNNER) DISTANCE BETWEEN EXISTING THERMOSTAT ' �� _- ^ PERPENDICULAR DESIGNATION STUD CONDITIONS - INTERIOR PARTITIONS _ ° NEW DEDICATED OUTLET SHEET TITLE: ' INTERSECTING WALLS OR ARCHITECTURAL .�_ HORIZONTAL BRACING CALCULATED USING 5 PSF AND L/240 ��� - 1 MIN. A BETWEEN WALLS EXCEEDS 3625125-18 ALL WALLS 11'-0" TO 12'-0" IN HEIGHT - 16" OC EXISTING CEILING GRID TO REMAIN. NEW CEILING TILES THROUGHOUT. GENERAL NOTES, CONT 18 GA METAL R1 LEGEND, AND ? ;� r FASTENED TO DECK AT 2'-•0" Co 'IP 111 y 8'-O OC +� OC STAGGERED ,. 3625125-18 ALL WALLS UNDER 11'-0" IN HEIGHT — 24" OC A EXISTING FIRE STROBE LOCATION TYPICAL DETAILS FASTEN RUNNER TOR // SAT CEILING „ EXISTING CEILING MOUNTED SMOKE DETECTOR ALL WALLS 12'-0" TO 16'-0IN HEIGHT - 16" OC 11 GYP BD .j AT 2'-0" OC T �" METAL STUDS SEE SPAN 3625162-43 ALL WALLS WITH TILE FINISH + EXISTING SPRINKLER HEAD EA SIDE r 11110004 TABLE FOR GAUGE AND >E SOUND BATT INSULATION AS OCCURS ,_j_ FE FIRE EXTINGUISHER CABINET LOCATION h i TYP AT DEMISING WALL SPACING ALL MIRRORED WALLS IN TOILET ROOMS I 1I I, METAL STUDS SEE WALL HEIGHT 3625162-68 ALL WALLS 16'-0" TO 24`-0" IN HEIGHT -- 12" OC EXISTING EXIT SIGN DRAWN BY: BL TABLE FOR GAUGE AND SPACING GYP BD EA SIDE BOTTOM TRACK TO FINISH �� 4 FLOOR W/ POWDER DRIVEN CHECKED BY: DMR PPA t ,: CONT ACOUSTIC SEALANT ANCHORS AT 4'–O" OC EA SIDE AGAINST TRACK SHEET: } NO SEALANT AT SIM CONDi' CONT ACOUSTIC SEALANT '1 . Al :• EA SIDE AGAINST TRACK 1/2" MAX . ` .. 1/2" MAX —_ - NO SEALANT AT SIM COND =Y .-__.________ BOTTOM TRACK TO FINISH w CONCRETE FLOOR W/ POWDER DRIVEN 0 CONCRETE SLAB Lu — — Q -.I JOB NO2080243.44. 9 WALL-I)? DEMISING I 10 WALL 6 ABOVE GRID I ( \ SPAN TABLE FOR METAL STUDS 0.1 3"=1'-0" Q A �,(�, AT FLOOR AND SUSPENDED CEILING 3"=1'-O" --1 0.9) NTS a PERMIT SET: 01/03/2019 3 J 3 (J) 208024344\4_0RAWINGS\ARCHITECTURAL\A0-01.0WG 8L 12/18/18 14:58 1:96.00 GENERAL PLAN NOTES IIMI A. SEE ARCHITECTURAL GENERAL NOTES ON A0.01 FOR ADDITIONAL INFORMATION B. SEE A0.01 FOR WALL TYPES <_> <tsl> M C. SEE A1.20 FOR FINISH SCHEDULE D. PATCH AND REPAIR ALL EXISTING WALLS WHERE AFFECTED BY NEW WORK. Architecture Interiors E. PAINT NEW AND EXISTING WALLS. LOW V.O.C. PAINT SYSTEMS TO BE UTILIZED,TO INCLUDE PRIMERS AS WELL AS FINISH PRODUCTS. Planning Engineering G. ALL WALLS TO BE PAINTED (P-1) UNLESS OTHERWISE NOTED. H. CENTER FLOORING TRANSITIONS AT CENTER OF DOOR JAMBS, UNLESS OTHERWISE NOTED. I. PROVIDE VINYL REDUCER AT ALL FLOORING MATERIAL TRANSITIONS, UNLESS OTHERWISE NOTED. J. SEE A0.01 FOR ADDITIONAL INFORMATION ON FIXTURE MOUNTING HEIGHTS.ALL REQUIRED ADA Portland,OR I I - I 9 I I I 9 CLEARANCES ARE TO FACE OF FINISH. 503.224.9560 if U . - K. INSULATE ALL UNDER COUNTER HOT WATER AND WASTE LINES. Vancouver,360.695.7879 WA It- �I41 ` 9--f- - - - 8 ''- - - - ill S L. CONFIRM REQUIREMENTS AND SIZES FOR ALL EQUIPMENT/APPLIANCES PRIOR TO CONSTRUCTION OF Seattle,WA CABINETRY/COUNTERS. 206.749.9993 OFFICE M. FINISH ENDS OF COUNTERS, DOORS, FACES,TYPICAL. WWW.mcknze.com rr Q I 404 CPT-2 0 0 N. ALL EXPOSED EDGES AT DOORS AND SHELVING TO BE P-LAM TO MATCH ADJACENT VERTICAL SURFACES. I P-1 g-, TYP 0. SCRIBE TO FIT CASEWORK AT ALL WALLS. MACKENZIE __I.4 DESIGN DRIVEN I CLIENT FOCUSED P. WRAP ALL EXPOSED EDGES WITH P-LAM UNLESS NOTED OTHERWISE. . / €04-A___ O. SHIM AS REQUIRED. Client VI===li I 0 1M `\\ - H 5A CBRE _11 � OFFICE 405 ��� 0 2 CB RICHARD ELLIS OP-1 I B-10 I I PLAN KEYNOTES 7 -1 OPEN OFFICE - ' 1 4u3 4 y - 6 1. DEMOLISH WALL FOR NEW RELITE. 1/-"--C6) i - P e ._ 2. NEW GLASS TENANT ENTRY. 6 (E) �, `a �/� - ° ( ,1620 3. NEW BUTT GLAZED RECITES. REFER TO ELEVATION, 21A1.20 Project 0 ik SUITE 401_ 1------ - "= I -, ;d- I� : ° OFFEE - I -, _ 4. EXISTING SINK AND FAUCET TO REMAIN, TENANT IMPROVEMENT 1tt , "'� 406 \ e 5. INFILL OPENING. . -0 _/. 1 1-E MEM h,� + 1- P-1 B-1 6. DEMOLISH EXISTING CASEWORK. RETAIN SINK AND FAUCET FOR REUSE. �-p Hi ha{ �;� \ _ ' ! 7. ALIGN NEW WALL WITH EXISTING. TRIANGLE III ` ` 0 �' O 8. PROVIDE NEW BUILDING STANDARD WINDOW COVERINGS (BL-1) AT ALL EXTERIOR WINDOWS. 132219E 68TH PARKWAY I 0 I I 0 \ti _yam_ R1 9. PROVIDE RUBBER TRANSITION STRIP BETWEEN CARPET AND CONCRETE. 97223 � OREGON GI _ co IDI ENTRY si) 10. DEMOLISH PLYWOOD PANELS AND ALL SURFACE MOUNTED POWER AND CONDUIT. �,' �T. + + 401A 401 402A 11. DEMOLISH ELECTRICAL PANEL. F © CN 1 ,.-_ :ii ' ri //r sr 0I I I II M P-1 r-B-1 j/4" I 41- _ _1 I li - I - - II �{ - 12. PROVIDE ADA DISHWASHER. �(` =,n;�-, x. 4 . (f G'ONFERENCE 4 ,l 3041 , " ai. vin 402 13. PROVIDE BEER TAP FOR TENANT PROVIDED KEGERATOR. PROVIDE IN CABINET DEDICATED POWER. �' 'ETER TO ""tt CPT-2 / 0 P-1 B-1 ill , 1• ' f 1 • f R )ORTLA D, OREGON -; 6 • gt ... e .,44 ' I I e 1P4) OF 0 SCHEDULE OF APPLIANCES . O MACKENZIE RESER ALL RIGHTS 2018 VED ALL APPLIANCES AT BREAK AREA TO BE BUILT-IN. THESE DRAWINGS ARE THE PROPERTY OF MACKENZIE AND ARE NOT TO BE USED OR REPRODUCED IN ANY MANNER, MICROWAVE: KITCHENAID KMBP107ESS WITHOUT PRIOR WRITTEN PERMISSION REFRIGERATOR: KITCHENAID KRBL102ESS REVISIONS: 1 DEMOLITION FLOOR PLAN 2 FLOOR PLAN DISHWASHER: ASKO,ADA STAILESS STEEL DISHWASHER, MODEL NO. TBDAI 0z ins REVISIONS REVISION DELTA M >-1 A1.14 1/8"-1'-o" ' A1.10 �� ��=i)_ONTHIS CLOSING DATE a SHEET I I I : I DOOR SCHEDULE DOOR GENERAL NOTES I • • DOOR NO. ROOM NAME DOOR OPENING DOOR FRAME DETAILS HARDWARE RATING COMMENTS 1. DOOR OPENING HARDWARE SHALL BE CENTERED BETWEEN 36"TO 38"ABOVE THE FLOOR. PANIC HARDWARE SHALL BE BETWEEN 36"TO 42". , SIZE THK TYPE MATL FINISH MATL FINISH GROUP 2. MAINTAIN MINIMUM CLEAR WIDTH AT STRICK SIDE 18"AT PULL SIDE, 12"AT PUSH SIDE. I 1 SHEET TITLE: 401A ENTRY 3'-0"X8'-0" -- FG GL -- 21A1.20 H-1 - - 3. MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED THE FOLLOWING: tri- - - - ., EXTERIOR DOORS 8.5 LBS - - - . .- DEMOLITION PLAN, 402A CONFERENCE 3'-0"X8'-0" -- FG GL -- -- -- 21A1.20 H-2 1 INTERIOR DOORS 5 LBS I I-. ii. ._if FLOOR PLAN, FIRE DOORS 15 LBS AND DOOR 404A OFFICE 3'-0"X8'-0" -- FG GL -- 2/A1.20 H-2 - 1 4. EXIT DOORS SHALL BE OPERABLE FROM INSIDE WITHOUT THE USE OF A KEY, SPECIAL EFFORT OR SPECIAL KNOWLEDGE. NO LATCH OR LOCKING �=' .• All `, - II DEVIDE EXCEPT PANIC HARDWARE PERMITTED. -- _ L� ri... - I ' - - Ili ',41:3 _,_I _ _ TILLM _ SCHEDULE 405A OFFICE 3'-0"X8'-0" FG GL -- 21A1.20 H-2 1 5.6. EXOITOR DOOR5ING SHALL NOT BEESHALL BE LESS THAN 03P0" WIDTH AND 6ERABLE WITH A N8" N HEIGHT. PROJECTIONS INCLGLE EFFORT AND SHALL NOT UUIRE TIGHT DING NG PANIC GRASPING WARERSHAISLING OF THE NO REDUCE THE Hill IPI ii11111 :; _- = - iI'!1111111111mitn.. r it _k1__ _�, IIIIIIIII. ABBREVIATIONS COMMENTS HARDWARE GROUPS 7. ALL GLAZING IN DOORS, ALL GLAZING LESS THAN 18" FROM FINISHED FLOOR, AND GLAZING WITHIN 24"OF DOORS AND LESS THAN 60" FROM FINISH OPENING TO LESS THAN 32" CLEAR WIDTH. _ - _ _'! .i I .I-` --. F ..i ., 'inFLOOR SHALL COMPLY WITH ALL LOCAL BUILDING CODE REQUIREMENTS FOR SAFETY GLAZING. (USE 1/2 TEMPERED GLASS MINIMUM, UNO.) I• ' - - EXIST EXISTING 1. FULL WIDTH RELITE. MAXIMUM WIDTH 14'-0". H-1: GLASS ENTRY 8. HANDLES, PULLS, LATCHES, LOCKS, AND OTHER OPERATING DEVICES ON DOORS, CABINETS, PLUMBING FIXTURES AND UTILITY FACILITIES SHALL HAVE 1 I I I ' FGLEVER OR OTHER SHAPE PERMITTING OPERATION BY WRIST OR ARM PRESSURE AND NOT REQUIRING TIGHT GRASPING PINCHING OR TWISTING TO4DRAWN BY: BL GL GLASS DEADBOLT WITH THUMBTURN FULLY GLAZED RECESSED DOOR CLOSER AND OPERATE, THE FORCE REQUIRED TO ACTIVATE SUCH EQUIPMENT, OTHER THAN EXTERIOR DOORS, SHALL BE NO GREATER THAN 5 POUNDS-FORCE. I GL BOTTOM DOOR RAIL. 9. SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION ON DOORS AND DOOR HARDWARE. CHECKED BY: DMR / PPA 10. COORDINATE WITH TENANT SECURITY VENDOR FOR SECURITY REQUIREMENTS. J H-2: GLASS ENTRY - II -- -- --II - - SHEET: RECESSED DOOR CLOSER A110 , , JOB NO. AI 2080243.44 KEY PLAN 2oso243. I Iii Auo FOURTH FLOOR PERMIT SET: 01/03/2019 208024344\4_DRAW1NGS\ARCHITECTURAL\A1-10.DWC BL 12/18/18 14:57 1:96.00 DOOR PULL (H-2), TEMPERED BUTT TYPCIAL GLAZING GENE RAL PLAN NOTES MFR RECOMMENDATIONS TYP 8 AHAAS rj,2 PER TTACH MANUFACTURER A. SUSPENDED ACOUSTICAL TILE CEILINGS AT 9'-0"AFF, UNLESS OTHERWISE NOTED. RECOMMENDA TIONS B. FOR SEISMIC BRACING OF SUSPENDED CEILING AND INTERSTITIAL EQUIPMENT SEE DETAIL A/15.20. C. PROVIDE HOLE FOR PENETRATION THROUGH SUSPENDED ACOUSTICAL TILE FOR ELEMENTS INCLUDING, <L> M BUT NOT LIMITED TO,SPRINKLER HEADS, CONDUITS, ETC., OF SUFFICIENT SIZE TO ACCOMMODATE ONE 1%1 al / / (1) INCH OF LATERAL MOVEMENT IN EVERY DIRECTION OF ASSEMBLY PENETRATING CEILING PLANE. PROVIDE ESCUTCHEON TO CONCEAL GAP BETWEEN CEILING TILE AND PENETRATING ELEMENT. Architecture Interiors D. EXISTING CEILING GRID TO REMAIN. PROVIDE NEW CEILING TILE THROUGHOUT. Planning Engineering / 7 / E. CENTER ALL DOWN LIGHTS, FIRE SPRINKLER HEADS, SMOKE DETECTORS AND ALL OTHER CEILING PENETRATIONS IN CENTER OF 2X2 PORTION OF 2X4 TILE, UNLESS OTHERWISE NOTED. 49 , . F. LIGHTING FIXTURES, MECHANICAL GRILLS, SECURITY DEVICES AND LAYOUT SHOWN FOR PRELIMINARY 9 DESIGN INTENT ONLY. DESIGN-BUILD ELECTRICIAN RESPONSIBLE FOR FINAL LAYOUT AND CONFIRMATION K:/, _--1 - 0 -_I OF COMPLIANCE WITH OREGON ENERGY CODE. Portland, OR o = 0 503.224.9560 I I 9 S �/ o w S 0 0 w `-' - W X W U Vancouver,WA . y_ _ _ 8 Cn u- 360.695.7879 ta - Seattle, WA 206.749.9993 '/ www.mcknze.com + MACKENZIE O1 \ \ DESIGN DRIVEN E CLIENT FOCUSED :1 - + I FIN FLF� Client Ir \/ + SEE DOOR j I, SEE DOOR \__ EQUAL PANELS / H ` SCHEDULESCHEDULE ATTACH TO FLOOR ER alk CBRE ,i 0 FULLY GLAZED DOOR ®FULLY GLAZED DOOR WITH RELITE MANUFACTURERERECOMMEN AP ONS N = 2 LU CB RICHARD ELLIS 7 + DOOR ASSEMBLY W o • , 1.20 1/2"-1'-°" 8 0 PLAN KEYNOTES + - - o ® 10 GENERAL NOTES: 1. OPEN CEILING . REMOVE ALL UNUSED OR ABANDONED PIPING,CABLING AND WIRING. PAINT ALL 0 - - -- A _ - - 6 .5.20 .5.20 +5.20 PLASTIC LAMINATE A. ALL COUNTER EXPOSED CEILING AND ANY ELEMENTS ON THE CEILING, INCLUDING HVAC (P-1). ���' 3'-0" 2'-6" 4 EQUAL C� 9'-0" / CASEWORK TOPS/EDGES (55-1). 2. PROVIDE GYPSUM HEADER AT CEILING TRANSITION, PAINT(P-1). REFER TO DETAIL 3/A5.20. Project + B. ALL NEW CABINET FACES SUS 401 + + , / ,� AND DOORS (PL-1). 3. PROVIDE UNDER CABINET LIGHTING (L-1) AT ALL NEW AND EXISTING UPPER CABINETS. 'I,Iv 0 - I �,1 4 ® -: - �- /\ • n C. ALL CABINET PULLS TENANT IMPROVEMENT / / / D. PROVIDE DEDICATED - - - - -� OUTLET FOR ADA ItioN / -- -� - -j --�� :j \ / NEW BEER TAP TRIANGLE III I DISHWASHER �' .'� \. V U E. PROVIDE DEDICATE 13221 SE 68TH PARKWAY 3 �, \ -I / �\ _ - - .� s __ _ U OUTLET AND TIG�ARD, OREGON '5.20 \ �� \ ! �. A FULL TILE BACKSPLASH COMPRESSOR FOR BEER 97223 71 I `)' / / (CT-i) TAP. + + / F. PROVIDE UNDER CABINET • / -\- / \ / ' \ ..- - / /- UNDER CABINET LIGHTING AT EXISTING + \ / i p V - - - - - -V ,/ LIGHTING AND NEW UPPER �� �r - YI t - 4 ` _ ���V�� • iS. �'1������ CASEWORK. j 3041 ,_.., ���� �`+�������� EXISTING SINK AND '�, pi 4ki ,� ����� fj���,,-� � ���♦ FAUCET TO REMAIN ADD/ALTERNATE KEYNOTES 1,....,.1.....1..._, 1 4 ® B f E UILT-IN ♦ ♦������ ♦��������� 'ETER TO + = N M'CROWAVE, ���♦�,���H�������. -1���� SOLID SURFACE AA. AS AN ADD/ALTERNATE DEMOLISH ALL EXISTING 2'X4'FIXTURES THROUGHOUT THE SUITE AND PROVIDE . I) �"� �E SPEC. I �•�•�•�♦•�S♦� �•+♦���•il ,�•�`����♦�♦�•�. COUNTER TOP 5 PENDED LINEAR FL XWERX P Fl • ��� • o ����� � � ���...- ��4. .110:me .� US PENDANTS ( U PROFILE) THROUGHOUT. • ORTLA`D, OREGON 3 e In /. 1 O O -- 0 O� I I\ "� PLASTIC LAMINATE BB. AS ANN ADD/ALTERNATE PROVIDE THREE DECORATE PENDANT FIXTURES IN THE CONFERENCE ROOM. I _ /' I I '� ADA / I I \ / \ ,/-1,...„.,.><: --1- CASEWORK OF li,, i, T / '\DISHWASHER, \`. ,/,,,, \ I N \ ` / / \ N /,/ \ /,/ N,\ / z 0 ALM[GHNSIRESERVED ` N / �./ �- RUBBER BASE (B-1) THESE DRAWINGS ARE THE PROPERTY --\ \ OF MACKENZIE AND ARE NOT TO BE USED OR REPRODUCED IN ANY MANNER, 3'-0" 2'-6" 2'-0" 2'-2" 2'-7" 2'-3" ATTACHED TOE KICK WITHOUT PRIOR WRITTEN PERMISSION / /I e / AT ADA SINK . BUILT IN FRIDGE CLR ¢ REVISIONS: PLAN 6 ELEVATION AT COFFEE m REVISIONS REVISION DELTA 5 REFLECTED CEILING _F- ›._i THIS CLOSING DATE A1.10 1/8"=1'-O" . 1.20 COFFEE 406 1/2" 1'-O" /2 1 -O W FIXTURE LEGEND W❑ SHEET I I EXISTING 2'X4'LIGHT FIXTURE TO REMAIN. HATCHED INDICATES FIXTURE ON 24-HOUR BATTERY BACK-UP, ' I I I SCHEDULE OF INTERIOR FINISHES , UNDER CABINET LIGHTING 1 • SECTION 06 40 00-WOOD, CASEWORK, METALS AND PLASTICS SECTION 09 30 00-TILE SECTION 09 90 00 - PAINT AND COATINGS 1. SOLID SURFACE QUARTZ 1. CERAMIC TILE 1. PAINT I SS-1: WILSONART QUARTZ SERENE 0100 CT-1: ANN SACKS, SAVOY MOSAICS, STANDARD GLAZE, COLOR CHALK, TYPE FIELD, P-1: BENJAMIN MOORE PM-3 DECORATORS WHITE DESIGN HIVE 2. PLASTIC LAMINATE 2. GROUT NOTE: _ SHEET TITLE: PL-1: (UPPER/LOWER CABINETRY VERTICAL SURFACES) FORMICA, COLORCORE2 GT-1: TBD NO VOC, LATEX SATIN PAINT TO BE USED ON GYPSUM BOARD WALLS UNLESS NOTED OTHERWISE. 111111.11 M REFLECTED 3202-90 OTTER, GLOSS FINISH ALL PAINTED CEILINGS TO BE FLAT FINISH. R-- CEILING PLAN, NOTE: I _ I „ ELEVATIONA SECTION 12 24 00 WINDOW SHADES - AND FINISH 3. DRAWER PULLS STANDARD GROUT: POLYMER MODIFIED CEMENT GROUT, SANDED OR UNSANDED,AS SPECIFIED - - - 1. WINDOW COVERINGS = - 4:� ; . IN ' IN ANS!A118.7. SEAL ALL GROUT. - I _ - H-1: DOUG MOCKETT DP3 SERIES 10"TYPICAL, SATIN CHROME FINISH OR APPROVED _ I�IIIII L : 41r:111:11111111111111 SCHEDULE EQUAL BL-i: TBD �1�11111 , �� ` L._. . .. . .. / IIIIIIIIIII� SECTION 09 62 00 - SPECIALTY FLOORING I _ Imo_ _ _ • _ 4. DOOR PULLS 1. SEALED CONCRETE Alik I �a --- � i • - -r �[ _ _ H-2: FORMS AND SURFACES, RECTANGULAR DOOR PULL, HDREC1511, US32D FINISH, CN 1: SEALED CONCRETE, DIAMOND POLISH I I I I I I I 24" LENGTH SECTION 09 65 00 - RESILIENT FLOORING I I DRAWN BY: BL A 5. WOOD BASE 1. RUBBER BASEJ � _ _ - ;; CHECKED BY: DMR / PPA B-2: 4" MDF PAINTED BASE. PAINT (P-1). B-1: FLEXCO 4" STRAIGHT BASE II. i II -- - - SHEET: SECTION 09 51 00 -SUSPENDED ACOUSTICAL CEILING SECTION 09 68 13-CARPET TILE 1. SUSPENDED ACOUSTICAL TREATMENT 1. CARPET TILE SAT-1: ARMSTRONG SECOND LOOK, DUNE, 2X4 WHITE,I" PRELUDE GRID CPT-1: SHAW: MINIMAL 59164, COLOR VERGE 64555 A1 .20 INSTALLATION: MONOLITHIC CPT-2: (CONFERENCE AND OFFCES) INTERFACE; SCANDINAVIAN 6080302505, COLOR N0. BERGEN 303100 Al) 1 KEY PLAN 'JOB 2 I 411 A1.10 FOURTH FLOOR PERMIT SET: 01/03/2019 208024344\4.DRAWINGS\ARCHITECTURAL\A1-20.DWG BL 12/18/18 14:54 1:96.00 FLOOR OR ROOF STRUCTURE POP RIVET RUNNER TO WALL ANGLE AT 2 ADJACENT BERC 2 WALLS, FASTEN CLOSURE ANGLE W/ #6 SCREWS 8" MAX. DIRECTLY TO WALL FRAMING CLIP I • i.dSOUND ATTENUATION BATT AS OCCURS A1 ADDITIONAL #12 WIRE SUPPORT AT ALL MEMBERS 'i% WITHIN 8" OF PERIMETER WALL TO UNDERSIDE OF6 IP "MI — LATERAL BRACING WITH APPROVED VERTICAL • • EXISTING DECK COMPRESSION STR()WTI T AT 12'—O" OC EA WAY 1/42*'' 2„ / • • • J + j SEAL © PERIMETER TYPICAL COUNTERSLOPE HANGERS IF MORE THAN 1: 6 OUT OF PLUMB • 4 0 CLEAR SILICONE Architecture Interiors // "ATTACHED • • 01 ---r • 3625125-18 METAL STUDS Planning Engineering , /, • • 43 W ® 16" oc 4.- WALL • •Q a `� cxo 1/4" TEMP GLASS ® IG AT WALL NTS OF BRACE c— �a BUTT GLAZEDLIGHT AS URS SIDE Portland, OR 0 NOTE: FOR UNATTACHED WALLS PROVIDE A I 362:125-30 METAL STUD ~ 3/4" GAP BETWEEN EDGE OF ANGLE AND CLIP BRACING TO ROOF 503.224.9560 V._ -- DO NOT SCREW BERC 2 CLIP TO TRACK cY STRUCTURE AT EA STUD Vancouver, WA � ' ALTERNATING n 360.695.7879 — TABLE MAX. LENGTH �'' RECEPTION AREA , FULL GLASS DOOR CROSS RUNNERS FIT BETWEEN MAIN RUNNERS Seattle, WA `�_$. `_ MAIN RUNNERS AT 4' O" OC SUPPORT WITH #12 1/2" DIA CONDUIT (EMT) 5'-10" 206.749.9993 ;'lAT WIRE AT 4'—O" OC OR WITH #10 WIRE AT 5'-0" OC EA WAY 3(4" DIA CONDUIT EMT) 7'-8" C° www.mcknze.com 6'—O" MAX ' " 1 DIA CONDUIT EMT) 9s-9" B(CEILING LATERALLY BRACE MAIN RUNNER TO STRUCTURE AT I2-0 OC N+ s, rt..-1..., EA WAY. BEGIN BRACING WITHIN 6'-O" OF PERIMETER AND 2" SGL 162S125-33 M L S UV 12'_O" B —0" AFF FROM CROSS MEMBER IN AREAS GREATER THAN 1,000 SF (1-5/8 x20GA) _ MACKENZIE NOTE: ALL GRID MEMBERS AND CONNECTION DEVICES TO BE OF AN BACK TO BACK 1625125-33 15'—O" DESIGN DRIVEN I CLIENT FOCUSED APPROVED TYPE AND HAVE A 180# CAPACITY. ALL LATERAL BRACING SECURE ALL HANGERS TO MTL STUDS (1-5/8"x2OGA) SAT CEILING Client WIRES TO HAVE A 200# CAPACITY. SUSPENDED CEILING BLDG STRUCTURE. SGL 2505125-33 MTL STUD 13'_6" BRACING TO COMPLY WITH ASCE7, ASTMC635, ASTMC636 AND TRAPEZE DUCT WORK AND (2-1/2"x20GA) OTHER LARGE BACK TO BACK 250S125-33 ASTME580 OBSTRUCTIONS 15'-0" MTL STUDS (2-1/2"x20GA) •4111 CBRE . a SUSPENDED CEILING BRACING CEILING TRANSITION FULLY GLAZED DOOR CB RICHARD ELLIS . NOTE: PROVIDE SEISMIC SEPARATION JOINTS IN CEILINGS GREATER NTS z 1 1/2"=1'—Q" TYPCIAL CC 3"=1'—O" 0 THAN 2,500 SF. PROVIDE HEAVY DUTY GRID SYSTEM. o Q Project SUITE 401 ATTACH STUD TRACK TENANT IMPROVEMENT / THROUGH GRID TO / WALL BEYOND \ / BRACE ABOVE 1SUSPENDED CLG N / / TRS E III221 SE gPARKWAY ASSEMBLY / TKilA1RD, OREGON GLAZING PER \ 97223 SPECIFICATION ,� /)45' Jr. Tl T CUT TILE FOR TIGHT ;14 25 GA 3 1/2" METAL STUD BRACING �� ` BRUSHED ALUMINUM FIT AT WALLS EACH END AND CENTERLINE OF NEW J�' 3041 I CHANNEL OPENING 411t$1)• "�, ,� RESILIENT SPACER �,, 'ETER '. LTO ,� Li'de------'.---.----- Q 5/8 GYP BD •_ I III Lu ATTACHMENT �� .I f r r �] li! . 0 FLOOR FINISH BOX HEADER W/ (2) FORT D, OREGON x GYP BD 1i 362S162-43 AND (2) \ 1.9b 3627200-43 W/#10 SCREWS �_ GLAZING CHANNEL OF Q - ®16 0.C. � ., TEMPERED GLAZING S 1 \ �_ © MACKENZIE 2018 WALL BEYOND ALL RIGHTS RESERVED \ THESE DRAWINGS ARE THE PROPERTY OF MACKENZIE AND ARE NOT TO BE FLOOR SYSTEM4USED OR REPRODUCED IN ANY MANNER, WITHOUT PRIOR WRITTEN PERMISSION i m REVISIONS: RECITE SILL DETAIL AT FLOOR m 8 BUTT GLAZING HEAD CONDITION o� REVISIONS REVISION DELTA 41!) THIS CLOSING DATE 1 1/2"=1'-0" Q £ 521 1 1/2"=1'-0" ¢ �o SHEET 12" CCR. 1 _ r \ U.N.O. SADJUSTABLE MELAMINE ., 13" 22" ' (3) ADJUSTABLE MELAMINE 4' MIN 1 \ [ SHELVES 1 LLJ PLASTIC LAMINATE FACES — — — PLASTIC LAMINATE FACES w =,_ - - > > w w = - - - DOOR PULLS, PER Lu - - - - - -- - - 1 DOOR PULLS, PER `n = = ELEVATION, TYPICAL Iw ELEVATION, TYPCIAL w o �� — _ _ = UNDER CABINET LIGHTING U' SHEET TITLE: ,` FULL TILE BACK SPLASH o-- FULL TILE BACK SPLASH ; INTERIOR DETAILS > 25" COUNTER Lu > 25" COUNTER SOLID SURFACE COUNTER r La SOLID SURFACE COUNTER Lur TOP > :I v) 1'--5" MAX TOP '�1 w / /- w 25 TOP , TO FAUCET L.J Lu CONTROLS v) DOOR PULLS, PER ` ,I U.N.O. ELEVATION, TYPCIAL I _ r ____y}\ , WRAP ALL EXPOSED PIPE -t)PER CODE . ,,, (1) ADJUSTABLE MELMAINE DRAWN BY: 8" (' SHELF, NO �_Z Q > > CHECKED BY: z w PLASTIC LAMINATE FACES w ' w _ I w SHEET: LU I 'C) ATTACHED RUBBER BASE RUBBER BASE u) `� I PER CODE ,16" � 6 T A5. 20 ., . • , 4 H -*, 1 11 ) 24 )r2'-o" / -3 )( JOB NO. 2080243.44 10 CABINET SECTION AT ADA SKINK W CABINET SECTION 12 CABINET SECTION W 5.23/4"=1'— . ¢ " co 5.2 " TYPICAL 0 ' m TYPICAL 3/4"=1'—Q m TYPICAL 3/4 =1 —� HM� SiT' 01/03/2019 0 0 20BO24344\4_DRAWI S\ARCHITECTURAL\A5-20.DWG BL 12/18/18 14:45 1:96.00