Loading...
Plans NORTHWEST RECEIVED • JUL 3 0 2020 ENGINEERING GROUP CITY OF TIGARD DUILDINE'1 DIVfofON Ms. Carley Davis July 24, 2020 Ram Jack West 862 Bethel Drive • . Eugene, OR 97402 - CITY OF TIGARD . OFFICE COPY REVIEWED FOR ODE COMPLIANCE Re: Mr. Steve Everton Approved: [ Site Inspection OTC: [ 13737 SW Benchview Terrace Tigard, OR Permit#: mem-[' j 007-5 Approved plans Address: t31 1 ivil J .GLJ'laws Suite #: Dear Ms. Davis, :hall be on inh '` Vtilzaz_e. B � Date: Y-; Per your request, a site inspection was performed at the above residence on July 21, 2020. The purpose of the site inspection was to provide a general assessment of the structural condition of the foundation at the residence. The inspection was strictly visual and limited to the exposed areas of the structure. Documents detailing the construction of the residence were not available for review. The residence is estimated to be approximately twenty-four (24) years old and for _ _-.....suieniat' s-is.assu ned.4e-_fare south. ..SPECIAL INSPECTION REQthKi) : AL!DITY OF PERMIT State of Ore-on Struc v �. ,SUANCE OF A PERMIT `: BAD' DON CONSTRUCTION 0 Concrete and Relnforcin _ , f De UMENTS AND OTHER �t DAT, SHALL NOT PREVENT 0 Bolts Installed in Concr= y. � THE;CODE OFFICIAL FROM ` `` ,s;. n REQUIRING THE CORRECTION • i7 pedal Moment-i2eslsti ! f f i �r' ,' 44, PiF,ERRORS.ORSC 106.4 ID R':?nforcing Steel &Pre- -- �' _ ' # $ ' `'- 4, - - II 111 • f 0 Structural Welding - ..� ;" 4' s' High-.r8rangth Bolting � . �_ • ., - , + V Structural Masonry ,,,.• , .,, .`.. 1 ❑ Reinforced Gypsum CJ LIABILITY 1 0 insulating Concrete Fill -'. • ❑ Spray Applied Fire-Reel �+ }i Y of Tigard and its I yeas shall not be 71 Pilings, Drilled Filers an -orcx pie for discrepancies .--t+' '► whlrn may appear hereino 0 Shotcrete ❑ Special Grading, Excavation and Filling i Image 1: Front Elevation s ❑ Smoke-CoM1@,C6 is a three-story wood framed structure. The residence has wood and masonry brick siding covering the exterior walls. The foundation of the residence is a wood floor system O Other Insped by.p ers-ar4.00ncrete beams. The roof consists of composite asphalt shingles and has fain gutters on all sides•of the residence. Per customer's request, the scope of the investigation was limited to the proposed remedial repair at the north deck foundation. The assessment of the foundation system in all other areas except for the wooden deck is out of the scope of this report. P.O. Box 10393/ Eugene, OR,97440/541.393.7363/ www.NWENGGROUP.coM Mr. Steve Everton July 24, 2020 Foundation Inspection Page 12 • 13737 SW Benchview Terrace Tigard, OR OBSERVATIONS Vegetation around the deck consists primarily of grassy and mulch covered areas with some small to medium shrubs. The residence does appear to have a sprinkler system on the south side of the residence. The surface grades on the north, east, and west sides of the residence appear adequate to drain water away from the foundation. The surface grades on the south side of the residence appear to be negatively sloped toward the foundation. No areas of ponding water were observed on any side of the residence. Some evidence of foundation movement was observed during the inspection which is noted on the attached Foundation and Elevation Assessment Plan (SK-1). The evidence consisted primarily of sloping deck floor and deck columns out of plumb Relative deck elevations were taken by NW Engineering Group. The floor elevations were taken on July 21, 2020 with a Ziplevel. The Ziplevel is a pressurized hydrostatic altimeter and works by measuring the difference in elevations between the base unit and the handheld unit. The basepoint was reportedly set to 0.0 inch and located near the southwest corner of the wooden deck. Negative elevations referenced are below the basepoint, and positive elevations are higher than the basepoint. The lowest point was recorded in multiple locations along the north exterior perimeter of the wooden deck. The high point was recorded in multiple locations along the south side of the deck along the residence exterior wall. The elevation differential between the low and high points of the deck was found to be about 4 'A inches. These elevations are shown on the attached Foundation and Elevation Assessment Plan (SK-1). RECOMMENDATIONS I recommend a total of four(4) helical steel piles and four(4) helical steel tiebacks be installed at the wooden deck. Pile locations are shown on the Foundation and Elevation Assessment Plan (SK-1). The steel piling system used should have an evaluation service report (ESR) recognized by ICC-ES showing compliance with the currently adopted International Building Code(IBC). The helical steel piling and tieback systems should have a minimum allowable working load of 10 kips and be capable of uniformly raising the foundation as applicable. The minimum installation torque for the helical piles is 2,300 ft-lbs. The purpose of underpinning the foundation is to support portions of the structure that has experienced some differential settlement. The underpinning piles are designed to support the structural loads in the immediate areas where they are placed and not to prevent uplift from soil heave. Maintaining uniform moisture around the foundation is very important. The landscape grades around the residence should be maintained to slope away from the residence where required. The landscape grades should slope away from the foundation at a minimum of%" per foot for six (6'-0)feet. The top soil should extend a minimum of one (1'-0)foot above the bottom of the grade beam and should not extend above four(4") inches below the bottom of the siding. All new fill soil should be clayey sand with a minimum Plasticity Index (PI) of twenty-five (25). Watering the soil around the foundation is also important during dry periods to help maintain uniform moisture in the soil. P.O. BOX 10393/Eugene,OR,97440/541.393.7363/WWW.NWENGGROUP.COM Mr. Steve Everton July 24, 2020 Foundation Inspection Page 1 3 13737 SW Benchview Terrace Tigard, OR This concludes this report. Observations made in this report pertain to the condition of the residence on the date of the inspection which is subject to change. No foundation warranty is expressed or implied by this report. If I can be of further assistance or should you have any questions about this report, please do not hesitate to contact me. *JO Sincerely, •S�agO PRO/rSe. *GtNE 4 o 1i 88'. PE 7. I044.30.2 4� OE STEFF� ExPIRES: bV.3d/LZ Sean Morrison E.I.T. Charles Steffensmeier P.E. Engineering Technician Civil Engineer Attachment: Site Plan (SK-0) Foundation and Elevation Assessment Plan (SK-1) Ram Jack Helical Pile and Tieback Detail with 4038 Bracket (SK-2) Footing & Pile Calculations Ram Jack 4038 Bracket Shop Drawing Ram Jack 2 7/8" Helical Pile Specification P.O. 10393/ Eugene, OR, 9 440/541.393.7363/WWW.NWENGGROUP.COM SW BENCHVIEW TERRACE 94' +/- - ENTRY + I N I 10.8' +/- 13737 SW BENCHVIEW TERRACE I ' \_ I � AREA OF N SPECIAL INSPECTIONS: WORK ° SPECIAL INSPECTIONS OF PILE INSTALLATIONS SHALL BE PERFORMED ACCORDING TO ESR 1854, SECTION 4.3, PARAGRAPH 2. INSPECTION SCHEDULE SHALL BE CONSISTENT OF VERIFYING AND PROPERTY DOCUMENTING PILE AND BRACKET NUMBERS ON SITE, FOLLOWED BY OBSERVATION OF THE FIRST INSTALLATION'S LOCATION, EMBEDMENT DEPTH,AND FINAL INSTALLATION TORQUE VALUE, i CORRELATED TO THE REQUIRED DESIGN LOAD. ONSITE LOG BOOK FOR REMAINING INSTALLATIONS WILL BE VERIFIED.A FINAL INSPECTION OF THE INSTALLED I REMAINING PILES AND LOG BOOK DATA WILL BE DOCUMENTED IN A BRIEF LETTER SUBMITTED TO THE BUILDING AUTHORITY. 96 SPECIAL INSPECTION OF ALL PILES ki- lam () SHALL BE PERFORMED BY /�`/ SITE PLAN NORTHWEST ENGINEERING GROUP. •CtL 0 PROF,. ve � IN EA. S�Oy TREE PRESERVATION NOTES: tt- 88 . 1.ALL HOLES ARE EXCAVATED NEXT TO THE /'ONIf`v NORTH STRUCTURE FOUNDATION 2.THE TOTAL AREA OF EXCAVATED HOLES<25 SOFT '30 20�b y�� °pe BTOO'� NORTHWEST STEVE EVERTON SHEET: EXPIRES: 13737 SW BENCHVIEW TERR. 5 -0 ENGINEERING GROUP TIGARD, OR P.O. BOX 10393 SCALE: I DATE: EUGENE, OR 97440 .541! 393-7363 1/30 1'-0 07/24/2020 2ND FLOOR WOODEN DECK EXISTING 13'-0' 13'-0" 13'-0" 6x12 TIMBER BEAM \ _ _ 01 02 03 04®1 -2Y2" T-4Yz 4Y2" -4Y" 1 I 3RD FLOOR I , T1 -1 %" T2 -2Y2" T3 3" T4 -�—WOODEN DECK 0" i 0, +y" 0„ +y„ l AC 3-CAR GARAGE ENTRY—\\ I I "".COVERED PATIO FOUNDATION & ELEVATION ASSESSMENT PLAN i NORTH 4.0 D PROpFS wee �G%N S/°9 LEGEND / 3 " ---- FLOOR ELEVATIONS TAKEN BY NWEG ON 07/22/2020 . +'; � � ® ---- HELICAL STEEL PILE (10 KIP CAPACITY) F�IFy ' 30.953 5sr ---- HELICAL STEEL TIEBACK(10 KIP CAPACITY) DOE STE0°.‘ EXPIRES: Iwo"' NORTHWEST STEVE EVERTON SHEET: k/)/ 13737 SE BENCHVIEW TERR. ZZ ENGINEERING GROUP TIGARD, OR SK-� P.O. BOX 10393 SCALE: DATE: EUGENE, OR 97440 (541 i 393-7363 3/32"= 1'-0 07/24/2020 --. (2) 1"0 ASTM-A36 ALL-THREAD STANDARD FASTENING STRAP - FASTENING APPROXIMATE EXTERIOR GRADE STRAP w/ ELEVATION, SOIL OR CONCRETE GUSSETS PAVING. (VERIFY EXACT CONDITIONS _ IN FIELD) �" TYP in 0 1 X" 0 ASTM-A36 EXISTING 6x6 It) ( ALL-THREAD TIMBER COLUMNNNN 3Y"0 SLEEVE WITH %4"0 SAE J429 GRADE 8 THRU BOLT f3 MAX. TIEBACK ASSEMBLY ole • CHIP-OUT POCKET IN EXISTING �- FOOTING FLUSH WITH FOUNDATION /� WALL. POCKET WIDTH SHALL EXISTING FOOTING C . ! APPROXIMATELY MATCH BRACKET (VERIFY DIMENSIONS I WIDTH. (IF APPLICABLE) IN FIELD) EXTENT OF EXISTING FOOTING BEYOND 2 W HELICAL TIEBACK (REF.TABLE 1 /REF. SK-1 BRACKET MUST SUPPORT THE FOR LOCATION) I - BOTTOM OF THE FOOTING AND SHALL w, NOT RELY ON POST-INSTALLED - ANCHORS FOR GRAVITY SUPPORT TIEBACK ° ' ASSEMBLY I TABLE 1 �1 PILE MIN. `\ ITEM BRACKET PILE HELIX SERVICE INSTALL. DIA. CONFIG. LOAD TORQUE HELICAL PILE(REF.TABLE 1) (KIPS) (FT_ LBS) ae'd PILE 4038 2 Ye" 10" 10 2,300 1 N F4 �:py TIEBACK 2�" 10 2,300 ` ' au. PE I i A oj!ft. . - r 4. TYPICAL HELICAL PILE DETAIL "I � �0 , 20'�° '`�Vr @ EXTERIOR GRADE BEAM 5 DOE BTEFFta EXPIRES: 11,0/2/ NORTHWEST STEV SHEET: SW BENCHVIEW TERR. TIGARD, OR SK-2 ENGINEERING GROUP P.O. BOX 10393 SCALE: DATE: EUGENE, OR 97440 541)393-7363 3/4"= 1'-0 07/24/2020 NORTHWEST PILE CALCULATION Date: 7/24/2020 , ENGINEERING GROUP Designer: Charles Steffensmeier, P.E. P.O. Box 10393 Project: Steve Everton Eugene, OR 97440 13737 SW Benchview Terrace Tigard, OR /d Design Loads: 400 PRop4. s Dead: �� °aGINF6R soy Roof= 0 psf e;,., 7r Third Floor= 0 psf Second Floor= 15 psf r" 4 4 i • ON a First Floor= ]5 psf i �30 20�a 0Y Walls= 0 psf o f 8TE1Ft"' EXPIRES: J Live: *Roof snow= 0 psf *Roof live= 0 psf Third Floor= 0 psf Second Floor= 40 psf First Floor= 40 psf *(the greater of the two) Vertical Design Loads: Tributary Widths: Roof= 0 ft » plf Third Floor= 0 ft 0 plf Second Floor= 8 ft » plf First Floor= 5 ft » pif Walls= 0 ft » pif Foundation self-weight= » pif 1 DL pif Live: Roof= ft » plf Third Floor= ft » plf Second Floor= ft » pif First Floor= ft » pif 2 LL pif (without roof LL) I LL plf ASD Loads: Load,w2= EDL+ELL plf (comb.#2 -without roof LL)OR Load, wa=EDL+ ELL(0.75) pif (comb.#4-with roof LL) Max. load w ASD= plf Page 1 NORTHWEST PILE CALCULATION Date: 7/24/2020 ENGINEERING GROUP Designer: Charles Steffensmeier, P.E. Pile spacing(6) = 13 ft= in Pile Working Loads: Pile Service Load, Pit= lbs (wall load x pile spacing) Pile Ultimate Load, PuLT = lbs *safety Factor of 2 Applied Minimum pile installation torque Q at' Tmin — Kr Required ultimate soil capacity(Quit)= lbs Pile 0= 2 7/8" Torque factor(Kr)= Minimum pile installation torque, (Tm;")= ft-lbs Bracket= 4038 Bracket Allowable Capacity= 19,700 lbs Page 2 Rev Revision note Date SIgnat Check NOTES: UNLESS OTHERWISE SPECIFIED No ure ed.. i 1R e uu 1'-3 1/2" Ili / 3 1/2" O.D. SLEEVE (FY=MIN. 65 KSI) \ I I { m- .. ________] 0 4I �n LIIIb I ,{ ,,�n '11111111141 'I I { {I f —L� 7?FASTENING STRAP WITH ! 1 IIo 1" DIA. ALL THREADS i {1 I I AND NUTS { jI � I !! !i I tI ui I tLf 2 7/8" DIA. HELICAL PILE \ 't `'r'` \ 4107.78 „/2 3" 3 12 FRONT VIEW igilui / 10" / 3 1/2" DIA. BRACKET SLEEVE 1111111 TOP VIEW 3/8" BRACKET SEAT A NOTES. - 1. POLYETHYLENE COPOLYMER THERMOPLASTIC COATING PER ICC-ES AC r 228 M ,� �I{{. 3. MANUFACTURER TO HAVE IN EFFECT INDUSTRY RECOGNIZED WRITTEN Co �11I QUALITY CONTROL FOR ALL MATERIALS AND MANUFACTURING LLLRIII I{�ill PROCESSES. 11 D -aus TYP. INSTALLATION r. 4. ALL WELDING IS TO BE DONE BY WELDERS CERTIFIED UNDER SECTION 5 i SCALE: 1"=1' OF THE AWS CODE D1.1. 5. THE CAPACITY OF THE UNDERPINNING SYSTEM IS A FUNCTION OF MANY INDIVIDUAL ELEMENTS. INCLUDING THE CAPACITY OF THE FOUNDATION, I BRACKET, PIER SHAFT. HELICAL PLATE, AND BEARING STRATA, AS WELL u5 { I AS THE STRENGTH OF THE FOUNDATION BRACKET CONNECTION AND ITHIS DRAWING AND ITS CONTENTS ARE THE QUALITY OF THE INSTALLATION OF THE PILE. YOUR ACHIEVABLE CONFIDENTIAL AND THE EXCLUSIVE PROPERTY CAPACITY COULD BE HIGHER OR LOWER THAN THOSE LISTED DEPENDING c.V I I OF RAM JACK SYSTEMS DISTRIBUTION, LLC. ON THE ABOVE FACTORS. NO PUBLICATION. DISTRIBUTION OR COPIES MA6. RAM JACK ENGINEERING HANDBOOK FOR ALLOWABLE VALUES AND/OR WRITTEN YBE MADEH EWIT THOF OUT THHE>EXPR EDAs CONDITIONS OF USE CONCERNING MATERIAL PRESENTED IN THIS DOCUMENT. SIDE VIEW DISTRIBUTION. LLC. ALL RIGHTS RESERVED UNDER COPYRIGHT LAWS. UNLESS OTHERWISE SPEWED • DIMENSIONS ARE IN INCHES FEE NO SHEET tt • TOLERANCES: ANGLE t1' 4038 PILE BKT. 2 OF 7 /2"-1 3 PLACE DECIMALS t .010 SEEE A-SIZE TITLE BLOCK RA1IIIJAC1( 2 PLACE DECIMALS t .02 ,0) • REMOVE ALL BURRS AND SHARP EDGES pRAyA1 10-2-08 CHARLES T.MARVIN • PARENTHETICAL INFO FOR REF ONLY HOLE TOLERANCES ow DARIN WILLIS .013 .„ , .128 ... .261 +ooe ASPR. DARIN WILLIS 7HRUmi THRu;661 TNRU:UU1 KSIIER 4038 HELICAL PILE BRACKET .125 .250 .500 501 751 +OtU 1.001+o1s REY WO NO + THRU-Poi TNRU-AM.750 1.000 2.000 4 0 3 8-0 2-0 7 IVOld10 2 . 875"0 HELICAL PILES AND ANCHORS - UPSET CONNECTION B t �(TYP.) , 71 : � �ri1 m � __ 11 00 00� � o0 00 �, ,, ___ oo . 11 I IT A" l LEAD SECTION HELIX EXTENSION EXTENSION MECHANICAL TORQUE RATING - 6,000 FT-LB LEAD SECTION TABLE HELIX EXTENSIONS ULTIMATE CAPACITY(TENS/COMP) - 54.0KIP* CAT.# "A" I "B" "C" "D" CAT# "A" ALLOWABLE CAPACITY(TENS/COMP)-27.0 KIP* `BASED ON A TORQUE FACTOR(Kt) = 9 6125 5'-0 8" 8605-8 5'-0 8• 6140 5'-0 8" 10" 8605-10 5'-0 10" 6142 5'-0 10" 12" 8605-12 5'-0 12" 6143 7-0 10" 12" 8607-10 7'-0 10" 3Y2 6147 7'-0 8" 10" 12" 6148 7'-O 10" 12" 14" EXTENSIONS 1 6188 10'-0 10" 12" 14" m N 1 CAT# "A" --9- I e"0 HOLES TO *MULTI-HELIX ARE SPACED 3 DIAMETERS 8605 5'-0 ) ACCEPT/4"0 OF THE LOWEST HELIX. 8607 7'-0 ( THRU BOLTS 8610 10'-0 I 1 I NOTES : I I 27A"O.D PILING 1. POLYETHYLENE POLYMER THERMOPLASTIC COATING PER ICC-ES AC 228.(GALVANIZED AND " - UNCOATED PILES AVAILABLE UPON REQUEST) CONNECTION 2. LEAD AND EXTENSION SECTION LENGTHS ARE NOMINAL. DETAIL 3. SHAFT MATERIAL IS 2%'O.D., 0.217"WALL, MINIMUM Fy=65 KSI AND Fu=80 KSI,ASTM-A500. 4. HELIX BLADE MATERIAL IS HOT ROLLED, MINIMUM Fy=50 KSI AND Fu=80 KSI CARBON STEEL. PLATE THICKNESS IS AVAILABLE IN%"AND Y2"THICKNESSES. 5. NOMINAL SPACING BETWEEN HELICAL PLATES IS THREE TIMES THE DIAMETER OF THE LOWEST HELIX. 6. MANUFACTURER TO HAVE IN EFFECT INDUSTRY RECOGNIZED WRITTEN QUALITY CONTROL AND RAMJACK ASSURANCE FOR ALL MATERIALS AND MANUFACTURING PROCESSES. 9 7. MANUFACTURER SHALL BE ISO CERTIFIED. 8. ALL WELDING IS TO BE DONE BY WELDERS CERTIFIED UNDER SECTION 5 OF THE AWS CODE D1.1. DWG.NO.:2075.03 CATALOG NO.:SEE TABLES REV.1 9. ALL COUPLING BOLTS TO BE "4, SAE J429 GRADE 8 BOLTS.(SAE J429 GRADE 5 IF GALVANIZED). scALE ORAWN By ��: umvu aNEFT1 OF 1 3d4'"T-0 SA