Loading...
Report Mec7_02o ocoS21 1)-1 Cx) ,2y P-D Unit Report For 48FC- 5T-E-3PH Project: Stock Units 2019 Q n' ! 02/19/2019 Prepared By: 04:57PM GI I . ,U St!Il_DING DIVISION Unit Parameters Dimensions(ft. in.)&Weight(lb.)*** Unit Model- _.-.____.48FCEA06A2A5-0AOA0 Unit Length: 6'2.375" Unit Size: — — ---06(5 Tons) Unit Width:..._... — — ....3' 10.625" Volts-Phase-Hertz. .._...__..._.._._— 208-3-60 Unit Height:_..._.__...__.__..._...___.....__.__. _.2'9.375" Heating Type- Gas *** Total Operating Weight: 511 lb Duct Cfg:........_...___.Vertical Supply/Vertical Return Medium Heat *** Weights and Dimensions are approximate. Weight does Standard One Stage Cooling Models not include unit packaging. Approximate dimensions are provided primarily for shipping purposes.For exact dimensions and weights,refer to appropriate product data catalog. Lines and Filters Return Air Filter Type. Throwaway Return Air Filter Quantity:-_.-_.__....._._...._...____...__.__._2 Return Air Filter Size:-_____..._ 16 x 25 x 2 Unit Configuration Direct Drive-EcoBlue-Medium Static Al/Cu-Al/Cu Base Electromechanical Controls Standard Packaging Warranty Information 1-Year parts(std.) 5-Year compressor parts(std.) 10-Year heat exchanger-Aluminized(std.) No optional warranties were selected. NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods. Ordering Information Part Number Description Quantity 48FCEA06A2A5-OAOAO Rooftop Unit 1 Base Unit Direct Drive-EcoBlue-Medium Static None Packaged Rooftop Builder 1.49n Page 1 of 7 Certified Drawing for 48FC- 5T-E-3PH Project: Stock Units 2019 02/19/2019 Prepared By: 04:57PM NOTES: \1X11 10(1AE1T(STw rbH111 a wt a WR.Nf11tt1 Asiwm a iww wins 11 7"1w UNIT J 1 � ��$UOEria(I nu110iO3 RI elan u�uli'we 11�� 'tt 11 PAST rc>nwat w 1.01xEx510A3 ARE[A IIILHEE IIIENSIONS 33 III 11 SIB w..-.,.+„1111Y11 NUM taw[n. Aalrtlla a L01fAC1. IY I 1 APE IN NILLINCTEES. UFCnN IHi] p12] 2. CENTER Of GRAVITY IIFCINS 3E 310 11 7/I CONNECTION SIZES [Ni] 13711 33-3/1 A 1 311'1351 DIA FIELD POWER SUPPLY ROLE NFCIr1f 33 3II 14 i/B 10111 3.MO.DIRECTION OF All FLOW _ I141] 13111 / E' (Ill DIA ICIER SUPPLY 1YOCIWT IOFCIU7 /1 311 wig 32-I10 . C 1 31/'(511 DIA GAUGE ACCESS PLUG 4. ALL VIE!DRAM USING RID ANGLE [1031] pill (1171 ' F OPONINAR HOOD (OPTIONAL/ 11 D TM'R27 DIA FIELD CONTROL RILING HOLE I 14071 E 3/1'-14 APT CONDENSATE WAIN (ASS) I p 112'-14 API 6A5 CONNECTION 16521 Il RETURN 1(1 1 U '2 112' (641 DIA POSER SUPPLY KNOCK-OUI l Jj . 1. THRU-IHE-BASE CHART �� C 10-1/1 THESE ROLES ACQUIRED FOR USE li'/;� Oar\��, 12T17 RETURN CIITIRDOIADD, ODlADD _.uiln7l//% 'ii1111111111n: '� Ail l�l�l1 THREADED RIRE AEO'D ROLE .\111�1 ///�� V/; I CONDUIT SITE USE SIZES 12Al.l 1 IIY 115Y 7/6' 122.21 04-1/0 V. s�� A 1IY _ 21Y 1/6'122.21 11120.01 T 2/-112 N 3N' PONEA 1-110'(2/.11 _ E ALT. 114114 1-011 11401 CONDExSATE ZI 1009ADDl 1/2'FPT GAS 1-11B'Q1.E1 I 2 DAA IA OPENING LI S11f FOR'1AIU-THE-BASEPAN' FACTORY OPTION, IA BAS0PHH SUPPLY 26-511 FITTINGS FOR ONLY 1. V.S I ARE PROVIDED (6151 SUIILY 11•IR 1 � I AIR . 11U1A1U1 PROVIDES 311'FPT THRU CIII DM 12-1/2 11-1/2THE ( I FLANGE S FITTING. 1 i2 i/ 12+1 1 SEE TNRU L• 1 ,I(L 1II / I BASE CHART C 11-1/1 25 23-3/4-� 3-1/4 4-1/4 [2511 I5G31 1011 (1311 1 2-1/0 HOUR HOED 113011 A 2N 25 - 17-3/1 (6151 CO861 At 2A 1-5/0 TOP 1110] E SATE ID-111 LECTRICAL CONDENSATED 12151 IPS] DISCONNECT 1 LOCATION ���� IITEA COIlEMSEA MACTORYCONTROL BDR .fTIONAY (441/0INSTALLEDIXOWR BLONER DISCONMECTACCE11 PANCL fHH7 ill OPTIONALI 1 ® SUIPLI AIR FTALLED INSTALLED [II I J COWOUTLETi� ANGLE • it-111 4J (3021 211/1 � /4[Xv 12 ���� � 15393 AIRSIDC i 4-510 12111 9 C" ��--•--- �wi � / H1!ii r0-1 •=• Oar fi�� MEI I r HANDLE 5-3/4 MIN 6-3/8 I 5-3/4 3-3// 46-5/8 4-311 11111 (1611 I1113 11461 (IS) 111161 30.116 12141 26.110 I11L1 E1/21 ir LEFT (18191 (TURD UNCOMIC RELIEF FROM WILT 4 P101 All RETURN RENT AIR ITC CLASSIFICATION SHEET DATE SUPEICERES 48FC D/-01 SINGLE PACKAGE ELECTRICAL REV 48T0003093 U.S. ECCN:NSR 1 or 3 09/01/18 06/22/18 COOLING NITN GAS NEAT A Packaged Rooftop Builder 1.49n Page 2 of 7 Certified Drawing for 48FC- 5T-E-3PH Project: Stock Units 2019 02/19/2019 Prepared By: 04:57PM l ��� na IMMO II III moron a Irt aIINTT twra[l IwN1Ya1 IN lINK WAIT a WRm WIIa6! a 1RNIn wen Nu9m rrw tl6 UNEN a[utlw m N! tftmT tart N..r.E a STD. UNIT CORNER CORNER CORNER CORNER C.6. HEIGHT w.,,,,,.1.�MNI Ninai an[nr9t u nN[aa w wa wc[mN[w aVIUAI. UNIT WEIGHT 4 WEIGHT(AI WEIGHT(B) WEIGHT ICI WEIGHT ID)- LBS. K6. LBS. KG. LBS. AG. LBS. KG. LBS. 66. 1 V 2 48109904 482 21$ 113 51 111 53 126 58 125 57 37 516(956] 21 1/16(1241 16 1/1(4641 46E0405 543 216 138 63 133 60 133 10 ' 136 63 36 1/2 19211 23 3/6 (5941 16 (1571 461C9106 536 232 142 61 136 /2 136 62 142 14 _36 112(9211 23 3/1 (5941 16 (4571 411C9101 607 275 162 13 152 69 141 64 151 66 36 19111 22 1/2 (5721 11 3/6(4921 9 STANDARD UNIT WEIGHT Id WITH LOW GAO NEAT AND WITHOUT PACKAGING. FOR OTHER OPTIONS AND ACCESSORIES.REFER TO THE PRODUCT DATA CATALOG. 1 BACK �,.. R12 1/2 ` WITN ECONOMIZER BACK 13181 ` >j . , , . • WITHOUT i \\ ECONOMIZER N000 CORNER A CORNER B ECONOMIZER OPTIONAL DOOR \ (OPTIONAL/ ' SWING 0 IN 4 � o i 1,41' yd=? Ia411 • *// _ — RIGHT — Y �l � P\\� y • � 11may, • S CORNER D LJ CORNER C ,"-- LEFT L X TOP 71-5/1 116161 - FRONT 1 ® } 1.NO F ® 01t ALL MINIMUM CLEARANCES LOCAL[OD[5 OR JURISDICTIONS (Al PREVAIL. Juiii 6. • ZCUARANLE 39fRRE WITF! SERVICE Nfi3! OPEMTWA . SURFACE WIIDUCIIWE BAER NOACEaUCm'E BARRER CLFARANCE T FRONT /8 [1219mm] 36 I014mm1 18 (4578m1 • �. ~� �`^�' LEFT /8 [1219mm1 42 [1061mm1 18 [4571m] BACK 18 [1219mm] 42 L1067mm1 18 [457mm1 ! FRONT BACK N/2NIO0 36 19148811 36 [914mm] I8 (457mm1 RIGHT 38 1914mm] 36 I914mm] 18 [457mm1 TOP 72 [1829mm] 72 [1829mm1 72 (1829mm] ITC CLASSIFICATIGH SHEET DATE SUPERCEIES 481C 04-07 SINGLE PACKAGE ELECTRICAL REV U.S. ECCN:NSR 2 OF 3 06/07/IR 06/2L16 CODLING WITH GAS HEAT 48TC063083 A Packaged Rooftop Builder 1.49n Page 3 of 7 Certified Drawing for 48FC- 5T-E-3PH Project: Stock Units 2019 02/19/2019 Prepared By: 04:57PM ��Q -�]Mli , M,7 If TA[( 118"a Itt tL11 P t01111U..................... \ i MT TM INPUTS WILl1 NOT 11MLM11 p yM11111M p,Ei Ml MfIN IXICMMML 0. 01-111Mw.fllMXl IITRI CONSENT - 11-I/8 III 11805.31 11Y51DE 1HE BASE RAIL A SEMI e - \ II \ I 'V 1v��I�♦ III �1}1 / / 41-1/4 � 0 11D1Y 5] IINSIDE THE BASE AA ILSI`` o ;0:1: 0 n �� ' INSIDE BASERAIL DIMENSIONS op .i uu BOTTOM I481 �TA],1. A 2A 1-3/8 11 1 3-1/1 6:13Y1 [13] ell 2A 3l1 3-1/8 1181 DETAIL C 1991 TIP 4 PLCS FILTER ACCESS PANEL CONP. CONDENSER I CONTROL AOY INDOOR BLOWER ITOOL-LESS/ ACCESS COIL I ACCESS PANEL ACCESS PANEL \ • PANEL O { } INDOOR COIL I I '�' e SEE DETAIL C ACCESS PANEL r {/ 'Cf 116 - 11 I = N I I - . IIt it 111111 Q ® l �1 .160 1 I L� BACK i •ILL I oOI ■ni�il�=m�fi=lir■ 13-I//nJ . 1 r r I i `r -'r 1 i 1-------2i-a L� [e2.01 11509.0] z-3/e SI /-,/B TYR.CU I1B0.11 iYP CURB FRONTWIDTH ITC CLASSIFICATION SHEET DATE WENCHES 48FC 04-01 SINGLE PACKAGE ELECTRICAL REV U.5. ECCN:NSR 3 OF 3 09/DT/18 06/22/18 COOLING PITH GAS HEAT 48T0003093 A Packaged Rooftop Builder 1.49n Page 4 of 7 Performance Summary For 48FC- 5T-E-3PH Project: Stock Units 2019 02/19/2019 Prepared By: 04:57PM Part Number:48FCEA06A2A5-0A0A0 ARI SEER' -------------------------------------..._...____...14.00 Base Unit Dimensions Unit Length: — — — _......._.._ _ — 74.4 in Unit Width: 46.6 in Unit Height: — — _.._..._._.__._. — _ — 33.4 in Operating Weight Base Unit Weight' —_._.._...__.—....-_ . _ 511 lb Total Operating Weight:.___..._.__ __.._.. _ — — — — — — 511 lb Unit Unit Voltage-Phase-Hertz:. .. --- _ — --.._.._.... — — 2083-60 Air Discharge: — — — — —.. _.. . __ — Vertical Fan Drive Type: - - - — - — --- - - ---- _ .._.._Direct Actual Airflow:-------------..__...___ —.._..------------------------__2000 CFM Site Altitude:. — — ..._... _... .. — — — _ ---39 ft Cooling Performance Condenser Entering Air DB: — — — 90.0 F Evaporator Entering Air DB:._---------..._...._._ _-------------------_-------__ -.__--------------------------.......----__78.9 F Evaporator Entering Air WB:.-------------------------------------------------.._...___._.._-____..._...___----------_--_--__64.7 F Entering Air Enthalpy: — — — — — . 29.64 BTU/lb Evaporator Leaving Air DB:___--------------....- -.............._....- ......_________________......— ....._ _..._57.0 F Evaporator Leaving Air WB:_..__.__.___.._.___ __._.._._......__....._...___.-.__________-_ 55.0 F Evaporator Leaving Air Enthalpy:.-.—__._.....___......___.__.......__.___....__.___._..._.__.__...__.___—.-.______-__—___....23.16 BTU/lb Gross Cooling Capacity: — - ---- - — --- —. _ ... -58.28 MBH Gross Sensible Capacity: — — — — -- --47.36 MBH Compressor Power Input:_ -- — _ — 3.88 kW Coil Bypass Factor: — — — _— — — 0.179 Mixed Air Outdoor Air Airflow:.__ — — -- -- --.._.._ 420 CFM Outdoor Air DB: — _ _ — — — — 90.0 F Outdoor Air WB: — — — — — — — ._..__. ._... _ ..._ _ — — 67.0 F Outdoor Air Htg.Temp.:. — — — — .22.0 F Return Air DB: — — — 76.0 F Return Air WB:.. — —_..__... _ — — — — 64.0 F Return Air Htg.Temp.: — — — __ -- — 70.0 F Heating Performance Heating Airflow: — — — — — _ _ _ — — _ 2000 CFM Entering Air Temp:.._....... — — — — — -- —..._...__. 59.9 F Leaving Air Temp: 100.7 F ------------------------------------------------------------------------------ Gas Heating Input Capacity:------------.___------____----------------------....-----__------------- _ - ---_82.0/110.0 MBH Gas Heating Output Capacity:-----------------__.._..._..___._... __-•------------------.__..----_____.____---------_65.0188.0 MBH Temperature Rise: — — — _ ._..._.. — — — _40.8 F Thermal Efficiency(%). -- — 80.0 Supply Fan External Static Pressure:----------------------------------------------_--_-- —.....__.....___._.-•-----------------------_.0.50 in wg Fan RPM:. - -- - — -- - -- - --- -- _..__._...--_ .1996 Fan Power: _— — — — 0.84 BHP NOTE:_...__......._...____..._....._..._... .._.__._____...___...__...____._...__...__.____.-.Selected IFM RPM Range: 239-2390 Electrical Data Voltage Range:.— — — — — —.187-253 Compressor#1 RLA — _.. _.._ _ __ — _. — 16 Packaged Rooftop Builder 1.49n Page 5 of 7 Performance Summary For 48FC- 5T-E-3PH Project: Stock Units 2019 02/19/2019 Prepared By: 04:57PM Compressor#1 LRA:. - - - - _......._....._._...._... 110 Indoor Fan Motor Type: - - - - - - -- - MED Indoor Fan Motor FLA: - 8.6 Combustion Fan Motor FLA(ea):---------.__._.._.---._--------------------.---------_..____---_...__-----------------.-._0.48 PowerSupply MCA:...__.._.__...__._..._.___.._.__._..___._._____.__._..___._.._...__._--•-•----------------------------------_...31 Power Supply MOCP(Fuse or HACK): - - - - 45 Disconnect Size FLA Disconnect Size LRA:.... 126 Electrical Convenience Outlet. _None Outdoor Fan[Qty/FLA(ea)] _ - - - - - - - 1 /1.5 Control Panel SCCR:5kA RMS at Rated Symmetrical Voltage Acoustics Sound Power Levels, db re 10E-12 Watts Discharge Inlet Outdoor 63 Hz 91.1 89.6 85.6 125 Hz 83.1 79.0 84.7 250 Hz 81.2 75.8 80.5 500 Hz 80.7 72.5 76.0 1000 Hz 73.6 71.2 72.4 2000 Hz 69.8 61.9 68.0 4000 Hz 66.5 55.0 62.8 8000 Hz 62.9 49.7 59.3 A-Weighted 81.0 75.3 79.0 • Advanced Acoustics lot A ,: ,.._.. _-' 444 1144 41(1 O it Advanced Accoustics Parameters 1. Unit height above ground:...._..._.__.._...__._...-.._._...30.0 ft 2. Horizontal distance from unit to receiver: 50.0 ft 3. Receiver height above ground. 5.7 ft 4. Height of obstruction:...__._... .__.__...__...__._... .__.__...0.0 ft 5. Horizontal distance from obstruction to receiver.....D.0 ft 6. Horizontal distance from unit to obstruction:-___-_--_0.0 ft Detailed Acoustics Information Octave Band Center Freq.Hz 63 125 250 500 1k 2k 4k 8k Overall A 85.684.780.576.072.468.062.859.389.2Lw B 59.4 68.6 71.9 72.8 72.4 69.2 63.8 58.2 78.5 LwA C 53.2 52.3 48.1 43.6 40.0 35.6 30.4 26.9 56.8 Lp D 27.0 36.2 39.5 40.4 40.0 36.8 31.4 25.8 46.1 LpA Packaged Rooftop Builder 1.49n Page 6 of 7 Performance Summary For 48FC- 5T-E-3PH Project: Stock Units 2019 02/19/2019 Prepared By: 04:57PM Legend A Sound Power Levels at Unit's Acoustic Center, Lw B A-Weighted Sound Power Levels at Unit's Acoustic Center, LwA C Sound Pressure Levels at Specific Distance from Unit, Lp D A-Weighted Sound Pressure Levels at Specific Distance from Unit, LpA Calculation methods used in this program are patterned after the ASHRAE Guide;other ASHRAE Publications and the AHRI Acoustical Standards. While a very significant effort has been made to insure the technical accuracy of this program, it is assumed that the user is knowledgeable in the art of system sound estimation and is aware of the tolerances involved in real world acoustical estimation. This program makes certain assumptions as to the dominant sound sources and sound paths which may not always be appropriate to the real system being estimated. Because of this, no assurances can be offered that this software will always generate an accurate sound prediction from user supplied input data. If in doubt about the estimation of expected sound levels in a space, an Acoustical Engineer or a person with sound prediction expertise should be consulted. Fan Curve 3.0 2.9 "C00 R• - °.PM 2.8 -2400 RPM 3000 RPM 2.7 2.6 2.5 2.4 2200 RPM 1.00 DI IP 2.3 2.2 2.1 ''2.00 2000 PPM 1.9 v1.8 22 1.6 _;800 r�PM y 1.5 1.3 -". ..-. d 1.3 9G00 RPM U 1.1 ` \` ` N 1.1 U)1.0 1400 RNA `_ 0.9 0.8 • 1200 RPM 0.7 0.6 ... P 1000 RPM 0.5 '+BHP \ 0.4 `800 RPM _ ,B • 1.00= - 0.3 600 RPM C. HP 0. 0.1 \` 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0 Airflow(CFM-thousands) RPM=1996 BHP=0.84 Maximum RPM=2836 Maximum BHP=3.00 SC-System Curve RP-Rated Point Packaged Rooftop Builder 1.49n Page 7 of 7 eMicroMet1 Date: Weights Units: Part Number. 12/4l2018 491bs/22.23kg ECD-SRTI2CA-D2DH Submitted To: wbeck@airefco.com Job: Notes: Economizer-Economizer-Ultra Low Leak Economizer,Vertical Orientation, Honeywell Jade W7220 Single/Multiple Speed Electromechanical Controller,Adjustable Dry Bulb Sensor,Honeywell Actuator.Painted Rain Hood With Aluminum Filter,Barometric Relief,All Necessary Panels And Hardware Included. Economizer Harness .. - with PL6 Plug y" .r, Filter Access Door Provided .f an Unit 16 13/16" �— Filters • ?! Communicating ,.. -.,. s'-�/ e , 171 �� Actuator ¢ '� ,�� F f J Barometric ReliefCI 1 Damper Economizer ° Outside Air Hood [�T - Sensor External Gear ' !. Side View Driven Dampers Knockouts for Wiring for Optional Prop Power Exhaust The Information contained in this drawing is the sole property of Micrometl Corporation.Any reproduction in part or whole without the written permission of Micrometl Corporation is prohibited. Indianapolis_3035 N.Shadeland Ave.,Indianapolis,IN 46226_800.MMC.HVAC••Sparks_905 Southern Way,Sparks,NV 89431_800.884.4MMC••Longview_201 Kodak Blvd.,Longview,TX 75602_903.248.4800 • MicroMetl Date: Weights: Units: Part Number: 1214/2018 491bs/22.23kg ECD-SRTI2CA-D2DH Submitted To: wbeck@airefco.com Job: Notes: Economizer-Economizer-Ultra Low Leak Economizer,Vertical Orientation,Honeywell Jade W7220 Single/Multiple Speed Electromechanical Controller,Adjustable Dry Bulb Sensor, Honeywell Actuator.Painted Rain Hood With Aluminum Filter, Barometric Relief,All Necessary Panels And Hardware Included. Compliant Economizer: 1. Title 24:Economizers meet California Energy Commission Title 24-2013/2016 prescriptive section 140.4(damper leakage etc.),and mandatory section 120.2.i for Fault Detection and Diagnostic controls(JADE HJW10). 2. ASHRAE 90.1:Economizers meet ASHRAE 90.1-2013/2016 damper leakage requirements,and meet 2016 Fault Detection and Diagnosis requirements. 3. IECC:Economizers meet IECC 2012,IECC 2015,and IECC 2018 for outside air,return air,and relief damper(when provided)leakage requirements,and IECC 2015 and IECC 2018 for Fault Detection and Diagnostic requirements.Note_IECC 2015 and IECC 2018 requires differential return air sensor,which is included in some models(i.e.D2XH)and must be ordered separately on others(i.e.D2DH,D2ZH). 4. AMCA:Outside air and return air(volume)dampers are AMCA Class 1A rated at 1"w.g.Refer to MicroMetl NS1 catalog sheet on web site for details.Relief air dampers(when provided)are also AMCA rated.Refer to GR1 series catalog sheet on web site for details. Features; kittV • For single or 2 speed indoor fan units with Central Terminal Board(CTB)and Compressor Staging Board.Other control options available. ;�ti rna • Gear driven design for trouble-free operation,eliminating slippage and binding associated with standard linkage. ~ •-o- ter:::' in • Includes assembled rainhood with aluminum water entrainment filters in the outside air section. " f11R • Rainhood is sloped for water runoff. fiRrom®"ot • Built-in barometric relief damper provided.Power exhaust options available. ",;M, •'% • All harnesses and plugs needed are provided. ": •53 rnru.nu.«.ua.• • Uses standard factory filter access door shipped with HVAC unit. MicroMetl Corporation • If factory hinged access door option is installed on unit,an additional kit is required to seal hinged door properly. certifies that the models GR1 and NSt shown -OEM part no.CRPECONV003A00 or MicroMetl part number 0640-0100-HDANGL herein are licensed to bear the AMCA Seal. NoteS' The ratings shown are based on tests and 1. Control systems include Honeywell W7220 JADE controller,mixed(supply)air temperature sensor,OA sensor in description,and spring-return procedures performed in communicatingacactuator(some include differential return sensor as noted). Publicationance 511wit AMCAd 511 and 2. JADE W7220 controller is field mounted in unit's control box. comply with requirements of the AMCA Certified 3. Mixed(supply)air sensor is field installed in indoor blower fan section. Ratngs Programs. 4. Differential return sensor(included in'-D2XH"and"-D2ZH"models or can be ordered separately MicroMetl Part No.9901-2022-DIFF JC2)is field the AMCA Certified P Y- Ratings Seal applies installed in return duct. to Air Leakage and Air Performance ratings. 5. ASHRAE,IECC,and Title 24 require the economizer controller be capable of reporting faults to a fault management application accessible by day-to-day operating or service personnel,or annunciated locally on zone thermostats or in some codes other devices are acceptable.Refer to applicable code requirements and to MicroMetl instructions for suggestions. 6. For older single speed models without the Central Terminal Board the"-D2"part number is replaced by"-DJ".(See separate submittal). The Information contained in this drawing is the sole property of Micrometl Corporation.Any reproduction in part or whole without the written permission of Micrometl Corporation is prohibited. Indianapolis_3035 N.Shadeland Ave.,Indianapolis,IN 46226_800.MMC.HVAC••Sparks_905 Southern Way,Sparks,NV 89431_800.884.4MMC••Longview_201 Kodak Blvd.,Longview,TX 75602_903.248.4800 0�J� Date: Weight: 931bs (US) 42.18kg (Metric) Part Number: 0537-014A-00010 MicroMeti RTU: Submitted to: Approved by: Notes: Knockdown Curb- 14 Inches Tall Non Insulated Full Perimeter, Using Micro-Lock Galvanized Metal Construction. Knockdown Roof Curb Without Pitch, Insulated Deck Pans Included, Includes Wood Nailer, And Gasket Package. • C D 1 314"Alt drain hole Opening for thru ��� Blocked top the bottom electrical ` 111•00corners connections lb, �E s Selected fight �PpIY H t �{ f-t- q t --r 1. B it Selected r � Height 1 CROSS SECTION L OF CURB ob-I 2 A - I.D. B - I.D. C - O.D. D - O.D. E F G H I J 67.37 37.18 40.68 L 70.87 13.87 20.25 32.06 13.62 1.75 3.31 `Flange dimensions may vary This Document Is The Property Of MicroMetl Corporation And Is Delivered Upon The Express Condition That The Contents Will Not Be Disclosed or used Without MicroMetl's Witten Consent. Master Revision'. QQQ1 B MicroMetl Reserves The Right To Discontinue,Or Change At Any Time,Specifications 6 Designs Wthou[My Nonce Incurring obligations. page Revision: 00 01 B ' Indianapolis_3035 N.Shadeland Ave.,Indianapolis,IN 46226_800.MMC.HVAC••Sparks_905 Southern Way.Sparks,NV 89431_800.884.4MMC••Longview_201 Kodak Blvd., Longview,TX 75602_903.248,4800 RECEIVED X ( 10N1 JUL 2 8 2020 (9L-D U n i CITY OF TIGARD General Data BUILDING DIVISION MODEL WCC048F300B WCC048F400B WCCO4BFWOOB WCCO60F100B WCC060F300B RATED VOLTS/PH/HZ 208-230/3/60 460/3/60 575/3/60 208-230/1/60 2D8-230/3/60 f'^ A.R.I.RATINGS(COOLINGIO BTUH 48000 46000 48000 60000 60000 Indoor Air Flow(CFM) 1600 1600 1600 2000 2000 - Power Input(KW) 5.05 5.05 5.05 6.49 6.32 EER/SEER(BTU/WATT-HR.)OO 9.50/ 10.00 9.50/10.00 9.50/ 10.00 9.25/10.00 9.50/ 10.00 Noise Rating No.® 8.4 8.4 8.4 8.4 8.4 RATINGS(HEATING►O (High Temp.)BTUH&C.O.P. 48000&3.14 48000&3.14 48000&3.14 60000&3.14 60000&3.14 Power Input(KW) 4.48 4.48 4.48 5.60 5.60 (Low Temp.)BTUH&C.O.P. 25300&2.04 25300&2.04 25300&2.04 35000&2.18 35000&2.18 Power Input(KW) 3.64 3.64 3.64 4.71 4.71 HSPF(8TU/WATT-HR.)® 6.80 6.80 6.80 6.80 6.80 POWER CONNS.-V/PH/HZ 208-230/3/60 460/3/60 575/3/60 208-230/1/60 208-230/3/60 Min.Brch.Cir.Ampacity0 28.3 13.8 11.1 41.1 31.5 Br.Cir.-Max. (Amps) 40 20 15 60 45 Prot.Rtg.-Recmd.(Amps) 40 20 15 60 45 COMPRESSOR CLIMATUFP" CLIMATUFF" CLIMATUFF" CLIMATUFFTM CLIMATUFF" No.Used-No.Speeds 1 - 1 1 - 1 -1 1 - 1 - Valts/PH/HZ 200-230/3/60 460/3/60 575/3/60 200-230/1/60 200-230/3/60 R.L.Amps-L.R. Amps 15.5-101 8.0-51 6.4-41 25.7-141 18.0-118 Brch.Cir.Sales.Cur.Amps 14.4 7.1 7.1 25 15.4 OUTDOOR COIL-TYPE PLATE FIN PLATE FIN PLATE FIN PLATE FIN PLATE FIN Rows/F.P.I. 2/ 15 2/15 2/15 2/15 2/15 Face Area(Sq.Ft.) 14.0 14.0 14.0 14.0 14.0 Tube Size(In.) 3/8 3/8 3/8 3/8 3/8 Refrigerant Control TXV BLEED TXV BLEED TXV BLEED TXV BLEED TXV BLEED INDOOR COIL-TYPE PLATE FIN PLATE FIN PLATE FIN PLATE FIN PLATE FIN Rows/F.P.I. 4/ 15 4/15 4/15 4/15 4/15 Face Area(Sq.Ft.) 5.4 5.4 5.4 5.4 5.4 _ Tube Size(In.) 3/8 3/8 3/8 3/8 3/8 Refrigerant Control ORIFICE-.088 ORIFICE-.088 ORIFICE-.088 ORIFICE-.096 ORIFICE-.096 Drain Conn.Size(in.) 3/4 FEMALE 3/4 FEMALE 3/4 FEMALE 3/4 FEMALE 3/4 FEMALE Duct Connections SEE OUTLINE DRAWING SEE OUTLINE DRAWING SEE OUTLINE DRAWING SEE OUTLINE DRAWING SEE OUTLINE DRAWING _. OUTDOOR FAN-TYPE PROPELLER PROPELLER PROPELLER PROPELLER PROPELLER No.Used/Dia.(in.) 1 /22 1 /22 1 /22 1 /22 1/22 Type Drive/No.Speeds DIRECT/ 1 DIRECT/ 1 DIRECT/1 DIRECT/1 DIRECT/1 CFM®0.0 In.W.G.© 3400 3400 3400 3400 3400 No.Motors-HP 1 - 1/2 1 - 1/2 1 -1/2 1 -1/2 1 - 1/2 Motor Speed R.P.M. 1080 1080 1080 1080 1080 Volts/PH/HZ 200-230/1/60 460/1/60 575/1/60 200-230/1/60 200-230/1/60 F.L.Amps-L.R.Amps 3.3/3.9-8.5 1.7-3.8 1.4-3.2 3.3/3.9-8.5 3.3/3.9-8.5 INDOOR FAN-TYPE CENTRIFUGAL CENTRIFUGAL CENTRIFUGAL CENTRIFUGAL CENTRIFUGAL Dia.xWidth(in.) 11.0 X 11.0 11.0X11.0 11.OX11.0 11.0 X 11.0 11.OX 11.0 No.Used 1 1 1 1 1 Drive/Speeds(No.) DIRECT/2 DIRECT/2 DIRECT/2 DIRECT/2 DIRECT/2 CFM vs.In.W.G.© SEE FAN PERF.TABLE SEE FAN PERF.TABLE SEE FAN PERF.TABLE SEE FAN PERF.TABLE SEE FAN PERF.TABLE No.Motors-HP 1 -3/4 1 -3/4 1 -3/4 1 -3/4 1 -3/4 Motor Speed R.P.M. 1080 1080 1080 1080 1080 Volts/PH/HZ 200-230/1/60 460/1/60 575/1/60 200-230/1/60 200-230/1/60 F.L.Amps-L.A.Amps 5.0/4.3-9.7 2.1 -4.8 1.7-4.0 5.0/4.3-9.7 5.0/4.3-9.7 FILTER-FURNISHED? NO NO NO NO NO Type Recommended THROWAWAY THROWAWAY® THROWAWAY THROWAWAY© THROWAWAY Min Face Area®-to(Sq. Ft.) 5.33 5.33 5.33 6.67 6.67 REFRIGERANT Charge(lbs.of R-22) 13.0 13.0 13.0 12.0 12.0 DIMENSIONS HXWXD HXWXD HXWXD HXWXD HXWXD Crated(in.) 39-3/8 X 47 X 66 39-3/8 X 47 X 66 39-3/8 X 47 X 66 39-3/8 X 47 X 66 39-3/8 X 47 X 66 Uncrated SEE OUTLINE DRAWING SEE OUTLINE DRAWING SEE OUTLINE DRAWING SEE OUTLINE DRAWING SEE OUTLINE DRAWING WEIGHT Shipping (lbs.)/Net(lbs.) 561 /521 561 /521 561 /521 579/539 4 539 MRated in accordance with A.R.I.Standard 210/240. ®Rated "^°`in accordance with A.R.I.Standard 270. "°'° ®Calculated in accordance with current prevailing Natl.Electric Code.Suitable for use with HACK circuit breakers or fuses. l �s a ®Standard Air-Dry Cal-Outdoor. 3 \ ® �a° ®Standard Air-Wet Coil-Indoor. � 'ram„ ®Rated in accordance with 0.0.E,test procedure.HSPF is at the minimum design requirement for Region IV. @Tillers must be installed in return air system.Above square images are based on 300 F.P.M.face velocity.If permanent filters are used,size per manufacturer's recommendation with clean resistance of 0.05"WC. 10