Loading...
Permit CITY OF TIGARD MASTER PERMIT t Permit#: MST2020-00222 - COMMUNITY DEVELOPMENT TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: Aug 12 2020 12:00AM Parcel: 1 S 135DB 12100 Jurisdiction: Tigard Site address: 11338 SW 91ST CT Subdivision: DAKOTA RIDGE Lot: 2 Project: Czech Project Description: Installation of a 5.44kW photovoltaic roof mounted solar system. BUILDING Floor Areas Required Setbacks Required Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left: 0 Parking Spaces: 0 Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke Dwelling Units: 0 Third: 0 sf Right: 0 Detectors: Total: 0 sf Value: $20,650.00 Rear: 0 PLUMBING Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0 Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain 0 Storm Sewer: 0 Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Drains: Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0 Other Fixtures: 0 Drywell-Trench Drain: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0 Heat Pump: N Hoods: 0 Other Units: 0 Furn<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 0 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add!500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Other: Y Other Description: Roof top PV system 5.44 kW Ecompasing: N BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: ALT SF VB R-3 0 Owner: Contractor: CZECH,CHRISTOPHER SUNLIGHT SOLAR ENERGY,INC. Required Items and Reports(Conditions) BUCKLEY,CORY 50 SE SCOTT ST BLDG#13 11338 SW 91 ST CT BEND,OR 97702 TIGARD,OR 97223 PHONE: PHONE: 541-322-1910 FAX: 541-550-2070 Total Fees: $358.19 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a coo of the rules or direct questions to OUNC by calling 503.232.1987 `or 1.800.332.2344. Issued By: �21-sti.w� Permittee Signature: �� :`�98— C�l= .a C . 9.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Building Permit Application RECEIVE v Residential FOR OFFICE USE ONLY Received JUL 0 9 2020 City of Tigard Date/By: 7//$/740 420 P-rnitNoti 5-T-uj2e-002Z 111111 e 13125 SW Hall Blvd.,Tigard,OR 97223 Plan Review ��A � S Phone: 503.718.2439 Fax: 503.598.19 CITY OF TIGARD �/ Zpj� m4 Other Permit: Da[eBy: TIGARD Inspection Line: 503.639.4175 BUILDING DIVISION Date Ready/By: Jur,s. ® See Page2 for Internet: www.tigard-or.gov Notified/Method:10,490 I.�IT7 7I� Supplemental Information J 15e % .„' TYPE OF - `i REQUIRED DATA:1-AND 2-FAMILY DWELLING . max; d ❑New construction ❑Demolition Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all A ElAddition/alteration/replacement ❑x Other: Solar equipment,materials,labor,overhead,and the profit for the \ CA'LF,GORY OF CONSTRUCTION work indicated on this application. ❑x 1 and 2-family dwelling ❑Commercial/industrial Valuation: $ 20,650.00 ElAccessory building 0 Multi-family Number of bedrooms: ID Master builder El Other: Number of bathrooms: JOB SITE INFORMATION AND LOCATION i Total number of floors: Job site address: 11338 SW 91st Ct. New dwelling area: square feet City/State/ZIP: Tigard,OR 97223 Garage/carport area: square feet Suite/bldg./apt.no.: Project name: Czech Covered porch area: square feet Cross street/directions to job site: Deck area: square feet Other structure area: square feet REQUIRED DATA:COMMERCIAL-USE CHECKLIST Subdivision: Lot no.: Permit fees*are based on the value of the work performed. Tax map/parcel no.: Indicate the value(rounded to the nearest dollar)of all equipment,materials,labor,overhead,and the profit for the ,II,X, DESCRIPTION OF WORK t V work indicated on this application. iiiInstallation of a 5.44kW photovoltaic tool mounted system. Valuation: $ Existing building area: square feet New building area: square feet © PROPERTY OWNER ❑ TENANT Number of stories: Name: Chris Czech Type of construction: Address: 11338 SW 91st Ct. Occupancy groups: City/State/ZIP: Tigard,OR 97223 Existing: Phone:( 419-367-2295 Fax:( ) New: ',_i ❑ APPLICANT El CONTACT PERSON BUILDINGPERMIT FEES* Business name: Sunlight Solar Energy,Inc. (Please refer to fee schedule) Structural plan review fee(or deposit): Contact name: Sean Flores Address: 7935 East Bumside Street FLS plan review fee(if applicable): City/State/ZIP: Portland,OR 97215 Total fees due upon application: Amount received: Phone:( 503-305-5397 Fax: :( ) E-mail: sear flores@sunlightsolar.com PHOTOVOLTAIC SOLAR PANEL SYSTEM FEES* .,: Commercial and residential prescriptive installation of CONTRACTOR roof-top mounted Photovoltaic Solar Panel System. Business name: Sunlight Solar Energy,Inc. Submit two(2)sets of roof plan with connection details 7935 East Burnside Street and fire department access,along with the 2010 Oregon Address: Solar Installation Specialty Code checklist. City/State/ZIP: Portland,OR 97215 Permit Fee(includes plan review $ Phone:( 503 )305-5397 Fax: and administrative fees): ( ) State surcharge(12%of permit fee): $ CCB lie.: 158922 Total fee due upon application: $ Authorized signature: ��yL,gg4 O4 This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. Print name: Scan Flores Date: 07/09/2020 *Fee methodology set by Tri-County Building Industry Service Board. 1:1Building\Permits1BUP-RESPermitApp.doc 02/24/2011 440-4613T(11/02/COM/WEB) Building Permit Application Checklist One- and Two-Family Dwelling FOR OFFICE USE ONLY City of Tigard Received Date/By: Permit No.: ■ 13125 SW Hall Blvd.,Tigard,OR 97223 Associated permits: Phone: 503.718.2439 Fax: 503.598.1960 TI ARll 24-Hour Inspection Line: 503.639.4175 0 Electrical 0 Plumbing 0 Mechanical Internet: www.tigard-or.gov ❑ Other: THE FOLLOWING ITEMS ARE REQUIRED FOR PLAN REVIEW Yes No N/A I Land use actions completed. See jurisdiction criteria for concurrent reviews. ❑ ❑ ❑ 2 Zoning. Flood plain,solar balance points,seismic soils designation,historic district,etc. ❑ ❑ ❑ 3 Verification of approved plat/lot. ❑ ❑ ❑ 4 Fire district approval required. Name of district: . 0 0 ❑ 5 Septic system permit or authorization for remodel. Existing system capacity ❑ 0 ❑ 6 Sewer permit. ❑ ❑ ❑ 7 Water district approval. ❑ ❑ 0 8 Soils report. Must carry original applicable stamp and signature on file or with application. ❑ 0 0 9 Erosion control 0 plan ❑permit required. Include drainage-way protection,silt fence design and location of catch- ❑ ❑ ❑ basin protection,etc. 10 3 Complete sets of legible plans. Must be drawn to scale,showing conformance to applicable local and state ❑ 0 ❑ building codes. Lateral design details and connections must be incorporated into the plans or on a separate full-size sheet attached to the plans with cross references between plan location and details. Plan review cannot be completed if copyright violations exist. IL Site/plot plan drawn to scale. The plan must show lot and building setback dimensions;property corner elevations(if ❑ ❑ ❑ there is more than a 4-ft.elevation differential,plan must show contour lines at 2-ft.intervals);location of easements and driveway;footprint of structure(including decks);location of wells/septic systems;utility locations;direction indicator;lot area;building coverage area;percentage of coverage; impervious area;existing structures on site;and surface drainage. 12 Foundation plan. Show dimensions,anchor bolts,any hold-downs and reinforcing pads,connection details,vent size ❑ ❑ 0 and location. 13 Floor plans. Show all dimensions,room identification,window size,location of smoke detectors,water heater, ❑ ❑ ❑ furnace,ventilation fans,plumbing fixtures,balconies and decks 30 inches above grade,etc. 14 Cross section(s)and details. Show all framing-member sizes and spacing such as floor beams,headers,joists,sub- 0 0 0 floor,wall construction,roof construction. More than one cross section may be required to clearly portray construction. Show details of all wall and roof sheathing,roofing,roof slope,ceiling height,siding material,footings and foundation,stairs,fireplace construction,thermal insulation,etc. 15 Elevation views. Provide elevations for new construction;minimum of two elevations for additions and remodels. ❑ ❑ ❑ Exterior elevations must reflect the actual grade if the change in grade is greater than four foot at building envelope. Full-size sheet addendums showing foundation elevations with cross references are acceptable. 16 Wall bracing(prescriptive path)and/or lateral analysis plans. Must indicate details and locations;for non- ❑ ❑ 0 prescriptive path analysis provide specifications and calculations to engineering standards. 17 Floor/roof framing. Provide plans for all floors/roof assemblies,indicating member sizing,spacing,and bearing ❑ ❑ ❑ locations. Show attic ventilation. 18 Basement and retaining walls. Provide cross sections and details showing placement of rebar. For engineered ❑ ❑ ❑ systems,see item 22,"Engineer's calculations." l9 Beam calculations. Provide two sets of calculations using current code design values for all beams and multiple joists ❑ ❑ ❑ over 10 feet long and/or any beam/joist carrying a non-uniform load. 20 Manufactured floor/roof truss design details. 0 0 0 21 Energy Code compliance. Identify the prescriptive path or provide calculations. A gas-piping schematic is required 0 0 ❑ for four or more appliances. 22 Engineer's calculations. When required or provided,(i.e.,shear wall,roof truss)shall be stamped by an engineer or ❑ ❑ ❑ architect licensed in Ore!on and shall be shown to be a..Iicable to the .ro'ect under review. JURISDICTIONAL SPECIFICS 23 Three(3)site plans are required for Item 11 above. Site plans must be 8-1/2"x 11"or 11"x 17". 0 0 0 24 Two(2)sets each are required for Items 16, 19,20 and 22 above. ❑ ❑ ❑ 25 Building plans shall not contain red lines or tape-ons. "Mirrored"building_plans will not be accepted. 0 0 ❑ 26 "Reversed"building plans must meet criteria outlined in the Permit&System Development Fees document. 0 ❑ ❑ 27 "Drawn to scale"indicates standard architect or engineer scale. 0 0 ❑ 28 Site plan to include tree size,type and location per approved project street tree plan(if applicable),and City of Tigard 0 0 ❑ Street Tree List. 29 Site plan to include trees and tree protection measures as required by conditions of approval. Tree locations,driplines, 0 0 0 and protection measures must be drawn to scale and must include the project arborist's signature of approval. 30 A Clean Water Services'Sensitive Area Pre-Screening Site Assessment form is required for all building additions, 0 0 ❑ including decks,patio covers(over non-impervious surface)and accessory structures to existing residential dwellings on a lot of record approved prior to September 9, 1995. 1:\Building\Permits\BUP-RESPermitApp.doc 02/24/2011 440-4613T(11/02/COM/WEB) 1.... . Electrical Permit Application RECEIVE • FOR OFFICE USE ONLY City of Tigard Received g Date/By: Permit ik: }�-At-.1rt 1 sl 13125 SW Hall Blvd.,Tigard,OR 97223 JUL 0 9 2020 Plan Review ���1 ✓L'9V / la Phone: 503.718.2439 Fax: 503.598.1960 Date/By: Related Permit t: 17GA1t I) Inspection Line: 503.639.4175 CiTY OF TIGARD Ready Date/By: tuns: Pi See Page 2 for Internet: www.tigard-or.gov Notified/Method: Supplemental Information TYPE OF WORK PLAN REVIEW ®New construction ❑Addition/alteration/replacement Please check all that apply(submit 2 sots of plans w/items checked): ❑Demolition ❑Other: 0 Service or feeder 400 amps or more D Building over three stories. where the available fault current 0 Marinas and boatyards. CATEGORY OF CONSTRUCTION exceeds 10,000 amps at 150 volts or 0 Floating buildings. ❑x 1-and 2-family dwelling ❑ Commercial/industrial 0 Accessory building less to ground,or exceeds 14,000 0 Commercial-use agricultural amps for all other installations, buildings. 0 Multi-family ❑ Master builder Other: Solar ❑ 0 Fire pump. ❑Installation of 150 KVA or JOB SiTE INFORMATION AND LOCATIONLOCATION _ !,;':A.Fa.a.ti 0 Emergency system. larger separately derived Job#: Job site address: 11338 SW 9lst Ct. ❑Addition of new motor load of system. 100HP or more. ❑"A" "E" "l-2" "l-3" City/State/ZIP: Tigard,OR 97223 ❑Six or more residential units. occupancy. ❑Health-care facilities. 0 Recreational vehicle parks. Suite/bldg./apt.#: Project name: Czech 0 Hazardous locations. 0 Supply voltage for more than 0 Service or feeder 600 amps or more. 600 volts nominal. Cross street/directions to job site: 1.--i-,:,, FEE SCHEDULE Description I Qty. I Each 1 Total 1 . New residential single-or multi-family dwelling unit. Subdivision: Lot#: Includes attached garage. 1,000 sq.ft.or less 168.54 4 Tax map/parcel#: Ea.add'l 500 sq.ft.or portion 33.92 I t - ,a e Limited energy,residential (with above sq.ft.) 75:00 2 Installation of a 5.44kW photovoltaic roof mounted system. Limited energy,multi-family 75.00 2 residential(with above sq.ft.) 4, ®.PROPERTY OWNER ❑ TENANT! ` " ° Renewable Energy 0 See Page 2 Services or feeders installation,alteration,and/or relocation Name: Chris Czech 200 amps or less 100.70 2 Address: 11338 SW 9I st Ct. 201 amps to 400 amps 133.56 2 --- 401 amps to 600 amps 200.34 2 City/State/ZIP: Tigard,OR 97223 601 amps to 1,000 amps 301.04 2 Phone: 419-367-2295 Fax:( ) Over 1,000 amps or volts 552.26 2 Email: chris[opher.d.ezech@gtttaiLcom Temporary services or feeders Installation,alteration,and/or relocation Owner installation:This installation is being made on property that I own which is not 200 amps or less 59.36 1 intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 201 amps to 400 amps 125.08 2 Owner signature: Date: 401 amps to 599 amps 168.54 2 13 APPLICANT El CONTACT PERSON ' Branch circuits—new,alteration,or extension,per panel A.Fee for branch circuits with Business name: Sunlight Solar Energy,Inc. above service or feeder fee, 7 42 2 each branch circuit Contact name: Sean Flores B.Fee for branch circuits without Address: 7935 East Burnside Street service or feeder fee,first 56.18 2 branch circuit City/State/ZIP: Portland,OR 97215 Each add'l branch circuit 7.42 2 Miscellaneous(service or feeder not included) Phone: (503)305-5397 Fax: :( ) Each manufactured or modular 67.84 2 Email: sean.flores@sun1ightsolar.com dwelling,service and/or feeder Reconnect only 67.84 2 CONTRACTOR ' ' + a` Pump or irrigation circle 67.84 2 Business name: Sunlight Solar Energy,Inc. Sign or outline lighting 67.84 2 Signal circuit(s)or limited-energy Address: 7935 East Burnside Street panel,alteration,or extension. ❑ See Page 2 2 City/State/ZIP: Portland,OR 97215 Each additional inspection over allowable in any of the above Additional inspection(I hr min) 66.25/hr Phone: (503)305-5397 Fax:( ) Investigation(1 hr min) 90.00/hr Email: sean.flores@sunlightsolar.com Industrial plant(1 hr min) 78.18/hr Inspections for which no fee is 90.00/hr CCB Lie.: 158922 Electrical Lic.: C556 Suprv.Lic.: 6110-S s ccificall listed 'A hr min Suprv.Electrician signature,required: iPe6m>t ,�X„,,,,,y Subtotal: Print name: Robert Johnson Date: 6/1/2020 0 Plan Review Required(25%of permit fee): State surcharge(12%of permit fee): Authorized signature: te,6 (j,, �,� TOTAL PERMIT FEE: �"" This permit application expires if a permit is not obtained within 180 Print name: Robert Johnson Date: 6/1/2020 days after it has been accepted as complete. * Number of inspections allowed per permit. 1:1Building'8ermits\ELC PerntitApp ELR_ERE.doc Rev 06/17/2015 440-4615T(1 I/05/COM/WEB Electrical Permit Application—City of Tigard Page 2—Supplemental Information Limited Energy Permit Fees: Renewable Energy Permit Fees: RESIDENTIAL WORK ONLY:" FEE SCHEDULE IlescriVt oll I Qlv. I loch ___ l oral Fee for all residential systems combined: S75.00 Renewable electrical energy systems: Check Type of Work Involved: 5 kva or less 00.70 2 5.01 to 15 kva I 133.56 133.56 2 ❑ Audio and Stereo Systems* 15.01 to 25 kva 200.34 2 Wind generation systems in excess of 25 kva: n Burglar Alarm 25.01 to 50 kva 301,04 2 50.01 to 100 kva 552.26 2 ❑ Garage Door Opener* >100 kva(fee in accordance with OAR 918-309-0040) 552.26 2 ❑ Heating,Ventilation and Air Conditioning Solar generation systems in excess of 25 kva: System* Each additional kva over 25 7.42 3 ❑ Vacuum Systems* >100 kva—no additional charge 0.0 3 Each additional inspection over allowable in any of the above: ❑ Other: Each additional inspection is 66.25/hr 1 charged at an hourly(1 lu min) Inspections for which no fee is 90.00/hr specifically listed '/ min) COMMERCIAL WORK ONL' 3 " ` 'P'i a:l.: Txicnl. PERMIT FEES' Fce for each commercial $75.00 Subtotal(Enter on page 1).system: y ' Number of inspections allowed per permit. (SEE OAR 918-309-0000) Check Type of Work Involved: ❑ Audio and Stereo Systems ❑ Boiler Controls ❑ Clock Systems ❑ Data Telecommunication Installation ❑ Fire Alarm Installation ❑ HVAC ❑ Instrumentation ❑ Intercom and Paging Systems ❑ Landscape Irrigation Control* ❑ Medical ❑ Nurse Calls ❑ Outdoor Landscape Lighting* ❑ Protective Signaling El Other: Total number of commercial systems: *No licenses are required. Licenses are required for all other installations I:\Building\Permits\ELC_PormitApp_ELR_ERE.doc Rev 06/1720/5 RECEIVED City of Tigard JUL 0 9 2020 ,111114 '' Building Division CITY OF TIGARD ' - .. 13125 SW Hall Blvd,Tigard,OR 97223 BUILDING DIVISION Phone: 503.718.2439 Fax: 503.598.1960 TIGARD Inspection Line: 503.639.4175 www.tigard-or.gov 2010 Oregon Solar Installation Specialty Code Check List for Prescriptive Installation of Roof-Mounted PhotoVoltaic Solar Panel System Property Information Installation Address: 11338 SW 91st Ct. City: Tigard, OR Zip: 97223 Owner's Name: Chris Czech Date: 07/09/2020 Contractor's Name: Sunlight Solar Energy, Inc. CCB #: 158922 Design Parameters of the Property/Structure If"Yes", does not Flood Hazard Is the installation I Yes qualify for the Area Located in a flood prescriptive path, follow plain/flood way? x No OSSC or ORSC for design requirements. 11 Wind Exposure Is the wind exposure Yes If"Yes", qualifies for "C" or less? ❑ No the prescriptive path. Installations on detached Is the Ground Snow single/two-family Load 70 psf or less? dwelling/single/two- If"Yes", qualifies for family townhomes x❑ Yes the prescriptive path. and/or their accessory Ground structures. ❑ No Snow Load Is the Ground Snow Installations on all Load 50 psf or less? structures other than ❑ If"Yes", qualifies for Yes the prescriptive path. above ❑ No 1 IJBuilding/Forms/PhotoVoltaic-Checklist02-01-I 1.docx Is the construction Type of material wood and does El Yes If"Yes", qualifies for the construction qualify Construction as conventional light ❑ No the prescriptive path. frame" construction? Is the spacing 24 inches or less? Pre-engineered trusses. ElYes If"Yes", qualifies for the prescriptive path. ❑ No Roof framing members Is the spacing 24 inches or less? Nominal lumber. ❑ If"Yes", qualifies for Yes the prescriptive path. ❑ No Is the combined weight [ Yes of the PV modules and If"Yes", qualifies for racking less than or ❑ No the prescriptive path. Solar equal to 4.5 psf? installation Is the solar installation ❑ layout in accordance Yes If"Yes", qualifies for with Section 305.4(3) of ❑ No the prescriptive path. the 2010 Oregon Solar Code? ❑ Metal Single layer If roofing material is Roofing Check the type of ❑ of wood one of the three types material roofing material shingle/shake checked, qualifies for Max. two layers the prescriptive path. 0 of composition shingle. Is the roof mounted 0 Yes Connections of solar assembly the solar assembly connected to roof — No If"Yes", qualifies for to the roof framing or blocking - the prescriptive path. directly? 2 I:Building/Forms/PhotoVoltaic-Checklist02-01-11.docx ❑ Yes If"Yes", qualifies for Is the gauge 26 or less? ❑ No the prescriptive path. 115 lbs for 60 inch spacing or less? If"Yes", qualifies for ❑ Yes the prescriptive path. ❑ No Minimum Uplift rating of Clamps? 75 lbs for 48 inches spacing or less? If"Yes", qualifies for ❑ Yes the prescriptive path. ❑ No Attachment of roof mounted Minimum 24 inches If the spacing falls solar systems Spacing of clamps? within 24 inches and 60 directly to inches Maximum 60 inches inches, qualifies for the prescriptive path. standing seam metal panels Width of roofing If the width of the panel panels? 18 inches or less is less than 18 inches, inches qualifies for the prescriptive path. Minimum#10 at 24 inches o/c? Size and spacing of I Yes If"Yes", qualifies for fastener? the prescriptive path. n No Is the roof decking of WSP min. Y2"thickness, ❑ Yes decking connected to If"Yes", qualifies for framing members ❑ No the prescriptive path. w/min. 8d nails @ 6"/12" o/c? Is the height less than or Maximum 18 inches equal to 18 inches? Height of the from the top of the If"Yes", qualifies for solar modules module to the roof Yes the prescriptive path. surface. ❑ No 3 I:Building/Fors/Photovoltaic-Checkli st02-01-11.docx Submittal Documents required for Prescriptive Installations Show the location of the PV system in relation to buildings, structures, property lines, and, as applicable, flood hazard areas. Site Plan Details must be clear and easy to read. Minimum size of the plan is 8.5 x 11 inches. Attach a simple structural plan showing the roof framing(rafter size, type, and spacing) and PV module system racking attachment. System must be shown in sufficient detail and clarity to assess whether it Structural Plan meets the prescriptive construction requirements as listed earlier above in the matrix. Minimum size of the plan is 8.5 x 11 inches. PV Modules Manufacturer: Hanwha QCell Model Number: Q.Peak Duo BLK-G5 320 Listing Agency: 4 I:/BuildinglForms/PhotoVoltaic-Checklist02-OI-11.docx