Report fPS O2o Ce0 777o 7/21k /2 Honeywell I Farenhyt Series OFFICE COPY Intelligent Fire Alarm Control Panel• IFP-300 / IFP-300B The IFP-300(red)and IFP-300B(black)are intelligent analog/addressable Fire Alarm Control Panels(FACP).The basic IFP-300 panel contains one built in signaling line circuit(SLC),which can support 159 IDP/SK sensors and 159 IDP/SK modules or 127 SD devices per loop.Additional SLC loops can be added using the model 6815 SLC expander for System Sensor devices to increase the overall point capacity to a maximum of 300 points per panel,or model 5815XL for Hochiki devices to increase the overall point capacity to a maximum of 254 points per panel. IFP-300 has the interconnection capability for up to 32 panels.The system has two modes of operation,multiple panels covering one larger building,or multiple independent buildings.To network panels together IFP-300 B use the SK-NIC network interface card.Copper wire or fiber optic cable panel connectivity can be used within the same networked system. IFP-300 has a built-in dual phone line,digital alarm communicator/ transmitter(DACT),IP or optional cellular technologies,Form C trouble relay,and two programmable Form C relays.IFP-300 has powerful features such as detector sensitivity,day/night thresholds,drift compensation,pre-trouble maintenance alert,and calibration trouble alert. The IFP-300 supports a variety of devices,including RA- 2000,RA-1000 or RA-100 remote annunciator,5824 serial/ parallel printer interface module(for printing system reports), FEATURES & BENEFITS • Network support for • IFP-300 can be • Network card allows • JumpStart • Supports Class B up to 32 Sites surface or flush copper network AutoProgramming' (Style 4)and Class A • Built-in support for up mounted connection with a feature for easy (Style 6 or Style 7 to 1591DP/SK • Built-in USB interface multi-mode or programming configuration for SLC, single-mode fiber and SBUS. detectors and 159 for programming • Supports up to four IDP/SK modules or connection option SWIFT wireless • Built in • Firmware can be 127 SD SLC devices upgraded in the field • Built-in dual phone gateways.Each synchronization for • Four line LCD display line,digital alarm gateway can have up appliances from • Renewable license on communicator/ to 49 wireless devices AMSECO,Gentex", with 40 characters per downloadin software ne 9 transmitter(DACT),IP System Sensor',and helps inhibit or optional cellular Wheelock • Available in a red or unauthorized technologies black cabinet programming IFP-300 Technical Specifications SPECIFICATIONS ORDERING INFORMATION Fora complete listing of all Physical: IFP-300-Intelligent Fire Alarm Control Panel. compliance approvals and Overall Dimensions:26.4"H x 16.4'W x4.11"D Red certifications,please Visit www.farenhyt.com. Weight:45 lbs. IFP-300B-Intelligent Fire Alarm Control Panel Color:Red or Black Black Microsoft,Windows,and the Windows Logo are Environmental Operating Temperature:32°F to SBUS ACCESSORIES registeredtrademarks 120°F (0°C to 49°C) or trademarks of Humidity:0 to 93%relative humidity(non- RA2000,RAl000,RA1000R,RA100, Microsoft Corporation. RA-2000GRAY-Remote annunciators • condensing) All other trademarks 6815-Signal Line Circuit(SLC)Expander for I DP/SK devices are the property of their ELECTRICAL: respective owners. IFP-300 Primary AC:120 VAC C 60 Hz,3.3ATotal 5815XL-Signal Line Circuit(SLC)Expander for Accessory Load:6A @ 24 VDC power-limited SD devices This document is not RPS-1000-Power Supply intended to be used for Standby Current:190 mA 5496-NAC Expander installation purposes.We Alarm Current:250 mA try to keep our product Battery Charging Capacity:17 to 55 AH 5824-Serial/Parallel Module information up-to BatterySize:18 AH max.allowed in control panel 5880-LED I/O Module date and accurate.We P cannot cover all specific cabinet.Larger capacity batteries can be housed in 5865 3/ 4-LED Annunciator p 5883-Rela Interface applications All ate RBB accessory cabinet. y all requirements.All specifications are subject APPROVALS MISCELLANEOUS ACCESSORIES to change without notice. NFPA 13,NFPA 15,NFPA 16,NFPA 70,&NFPA SKSS-3-Software Suite.Provides ro For Technical 72:Central Station;Remote Signalling;Local programming,g,upload/download and event Support,Please call Protective Signalling Systems;Auxiliary Protected reporting 800-446-6444. Premises Unit;&Water Deluge Releasing Service RBB-Remote Battery Box Cabinet.Use for Other Approvals: backup batteries up to 35 AH. UL Listing;CSFM(pending);COA(pending); Dim:16"W x 10"H x 6"D OSHPD(CA)(pending),FM(pending) SK-SCK-Seismic Compliance Kit SK-NIC-Network Interface Card APPROVED RELEASING SOLENOIDS SK-NIC-KIT-Network Interface Card in Cabinet Asco T8210A107 24 VDC 3A max 0 Hz SK-FML-Multi Mode Fiber Card Asco 8210G207 24 VDC 3 A max 0 Hz SK-FSL-Single Mode Fiber Card CELL-MOD-Cellular Communicator in Plastic COMPATIBLE DEVICES Enclosure See the data sheets listed below for a complete CELL-CAB-SK-Cellular Communicator in listing of the IDP,SK,SWIFT or SD devices. Metal Enclosure with lock and key 350361-IDP Device Protocol data sheet 53623 - SK Device Protocol data sheet 350360-SD Device Protocol data sheet 350615&350617-SWIFT devices data sheet For more information www.farenhyt.com Honeywell 12 Clintonville Road Northford,CT 06472 800 328 0103 Doc 351603IRev A I 05/17 Honeywell www.farenhyt.com ©2017 Honeywell International Inc. Farenhyt KNIGT �j KNIGHT by Honeywell Addressable Single Action and Dual Action Agency Listings Pull Stations MEA IDP-Pull-SA & IDP-Pull-DA UL 67-02-E Vol.IX The IDP-Pull-SA is a single action pull station requiring only one , For IDP-Pull-nA motion to activate the station.The IDP-Pull-DA is a dual action pull station requiring two motions to active the station. Both pull stations are designed to work with Silent Knight IFP-series fire FIRE alarm control panels (FACPs). Features • • Installer can open station without causing an alarm condition l PULL DOWN t • Dual-color LED is visible through handle of station blinks green to indicate normal operation and remains steady red in an alarm condition � J • Key operated test and reset lock using lock plate actuator • Key matches compatible FACP locks SILENT ti KNIGHT • Meets the Americans with Disabilities Act Accessibility c Guidelines (ADAAG) controls and operating mechanisms guidelines (Section 4.1.3[13]) IDP-Pull-SA • Meets ADA requirement for 5 lbs maximum pull force to active / S • Shell, door, and handle molded from durable LEXAN® FIRE • Reliable analog communications for trouble-free operation • Braille text on station handle • Handle latches in down position and the word Activated PUSH IN appears, clearly indicating the station has been pulled 1 PULL DOWN 1 • Rotary address switches for fast installation • UL Listed, including UL 38, Standard of Manually Actuated Signaling System El Installation SILENT ti KNIGHT ■I The IDP-Pull-SA and IDP-Pull-DA can be surface mounted to an o SB-I/O surface back box or semi-flush mounted on a standard single-gang with a minimum depth of 2.13"(5.40 cm) or double- IDP-Pull-DA gang or 4" (10.61 cm) square electrical box. You can also use the Compatibility optional (System Sensor® PN BG-TR)trim ring if the station is The IDP-Pull-SA and IDP-Pull-DA are being semi-flush mounted. compatible with the following FACPs: • IFP-2000 /RPS-2000 Intelligent Fire Panel • IFP-1000 /ECS Intelligent Fire Panel • IFP-100 / ECS Intelligent Fire Panel • IFP-50 Intelligent Fire Panel P/N 350286 Rev F • ©2013 Honeywell International Inc 21 Class A IN — SLC + OUT Class B Compatible FACP 111. IME Class A Wiring: Class B Wiring' IJ i " Wiring IDP-Pull-SA&IDP-Pull-DA Pull Stations Specifications* Ordering Information Physical IDP-Pull-SA Single Action Pull Station Height: 5.5"(14 cm) IDP-Pull-DA Dual Action Pull Station Width:4"(10.2 cm) Depth: 5.4 oz. (3.7 cm) Accessories BG-TR Optional trim ring. Housing Material: LEXAN polycarbonate resin SB-I/O Surface backbox, indoor/outdoor. Bi-Colored LED: Blinking Green: Normal *Unless otherwise noted,specifications apply to IDP-Pull-SA and IDP-Pull-DA. Steady Red:Alarm Switch: Single pole, single throw(SPST)normally open (N/O) switch which closes upon activation of the pull station Electrical Operating Voltage: 15-32 VDC Operating Current(LED flashing): 300 pA Wire Gauge: Up to 12 AWG (3.1 mm2) Environmental Operating Temperature 32°—120°F (0°C—49°C) Humidity: 10%—93% non-condensing SILENT This document is not intended to be used for installation purposes.We try to keep our 1110 product information up-to-date and accurate.We cannot cover all specific applications KNIGHT or anticipate all requirements.All specifications are subject to change without notice. For more information,contact Silent Knight 12 Clintonville Road, Northford,CT 06472- b Hone well immemonommi 1610 Phone:(800)328-0103, Fax:(203)484-7118. For Technical Support, Please call y y 800-446-6444. www.farenhyt.com Made In the U.S.A. Far e n Ii y t Addressable Photoelectric Smoke Detector & Photoelectric Smoke with Thermal IDP-Photo & IDP-Photo-T The IDP-Photo is a photoelectric smoke detector and the IDP-Photo-T is a photoelectric smoke detector with thermal. These (01 M EA plug in smoke detectors, with integral communication, provide features that surpass conventional detectors and are for use with 225-02-E Vol.V Silent Knight IFP-series fire alarm control panels (FACPs). Detector sensitivity can be programmed from the FACP software. Sensitivity is continuously monitored and reported to the FACP. ..,. Point ID capability allows each detector's address to be set with rotary address switches, providing exact detector locations for selective maintenance when chamber contamination reaches unacceptable levels. s�. IDP-Photo and IDP-Photo-T have a unique optical sensing chamber that is engineered to sense smoke produced by a wide range of combustion sources. In the IDP-Photo-T, dual electronic thermistors add 135°F (57°C) thermal technology to maximize detection. IDP-Photo(Base Not Included) Features • Sleek, low-profile design • Reliable analog communications for trouble-free operation • Age resistant polymer housing • Dual electronic thermistor design on the IDP-Photo-T • Superior EMI resistance for reliability • Simple field cleaning for code compliance • Variety of mounting options to meet any application • Dual LED indicators for 360°visibility • Detector transmits signal to indicate maintenance is required IDP-Photo-T(Base Not Included) • Optional remote LED annunciator(PN SSRA400Z) • Plug-in mounting provides ease of installation Compatibility The IDP-Photo and IDP-Photo-T are • Tamper-proof feature available on mounting bases compatible with the following IDP-series • Listed for use in duct applications detector bases: • Rotary address switches for fast installation • IDP-6AB 6" Mounting Base • UL Listed • SSB501 4" Mounting Base • SSB224BI 6" Isolator Base Installation • SSB224RB 6" Relay Base • The IDP-Photo and IDP-Photo-T plug into a compatible IDP-series SSB501 BHT 6"Temporal Sounder Base detector base. The IDP-Photo and IDP-Photo-T are compatible with the following FACPs: • IFP-1000 Intelligent Fire Panel • IFP-100 Intelligent Fire Panel • IFP-50 Intelligent Fire Panel SILENT 7550 Meridian Circle Maple Grove,Mn 55369-4927 its KNIGHT 763-493-6455 P/N 350280 Rev B,04/10/06 1-800-328-0103 Copyright©2006 Silent Knight Fax:763493-6475 by Honeywell www.farenhyt.com SLC OUT IN Compatible FACP RA400Z(Optional) MIIIIM (41 1....;:7:. ',,,40' tfr), (-- :,-,.., ,,,- Aa , . -1/4iity ....- . , , , : ClassA Optional Wiring , ..._........._............_....._................._...._..-.. Wiring IDPSeries Detector Mounting Bases Specifications* Ordering Information . Physical IDP-Photo Photoelectric Smoke Detector Height: 2.0"(5.0 cm) IDP-Photo-T Photoelectric Smoke Detector with Diameter:4.1"(10.4 cm) Thermal (135°F) Shipping Weight: 5.2 oz. (147 g) Accessories Electrical SSRA400Z Remote LED Annunciator. Operating Voltage: 15-32 VDC SSRMK400 Recessed Mounting Kit. Provides low Standby Current: profile for use with SSB501. 250 pA @ 24 VDC(no communication; LED off) SSXR2B Detector Removal Tool.A removal and 300 pA @ 24 VDC(one communication every 5 sec with replacement tool for IDP plug-in detectors. LED enabled) Includes the SST55-127-000. Alarm Current: 6.5 mA @ 24 VDC max(with LED on) SSM02-04-01 Detector Test Magnet. Environmental SSM02-09-00 Test Magnet with Telescoping Handle. Operating Temperature SSXP-4 Extension Pole for SSXR2B. Extends from IDP-Photo: 32°— 120°F (0°C—49°C) 5—15 ft. IDP-Photo-T: 32°—100°F (0°C—38°C) SST55-127-000 Detector Removal Head. Humidity: 10%—93% non-condensing SSBCK-200B Black Detector Kit. For IDP-series Other Ratings detectors. IDP-Photo-T Thermal: Fixed temperature setpoint 135°F(57°C) *Unless otherwise noted,specifications apply to IDP-Photo and Velocity: 0—4000 fpm (0—20 m/sec) IDP-Photo-T. IDP-Photo Insect Screen Hole Size: 0.016"(0.41 mm) nominal SILENT This document is not intended to be used for installation purposes.We try to keep our KNIGHT product information up-to-date and accurate.We cannot cover all specific applications fe or anticipate all requirements.All specifications are subject to change without notice. IMNIIIIII s For more information,contact Silent Knight 7550 Meridian Circle Suite 100, Maple by Honeywell Grove,Mn 55369-4927.Phone:(800)328-0103,Fax: (763)493-6475. Made in the U.S.A. Farenhyt ¶ SILENT KNIGHT by Honeywell Intelligent Device Addressable Monitor Module Agency Listings IDP-Monitor +T`-"" �(0 MEA The IDP-Monitor is an addressable monitor module for use with _ ?' 38e-0-e-voi 2 Silent Knight IFP-series fire alarm control panels (FACPs). The l• I IDP-Monitor acts as an interface to contact devices, such as waterflow switches and pull stations. trkt The IDP-Monitor supports Class A supervised or Class B ro supervised wiring to the load device. Conventional 4-wire • -.4- smoke detectors can be monitored for alarm and trouble $ RA conditions. Features • Single contact monitor • Support for Class A and Class B wiring IDP-Monitor • Fully supervised • Panel controlled status LED that flashes green in normal state Compatibility and is solid red in alarm The IDP-Monitor is compatible with the following FACPs: • Attractive ivory cover plate • Rotary address switches for fast installation • IFP-2000 / RPS-2000 Intelligent Fire Panel • SEMS screws for easy wiring • IFP-2000ECS Emergency Communication • UL Listed System with Fire Panel • IFP-1000 / ECS Intelligent Fire Panel Installation • IFP-100/ ECS Intelligent Fire Panel The IDP-Monitor mounts directly into a 4" square electrical box. • IFP-50 Intelligent Fire Panel The box must have a minimum depth of 2-1/8".A surface mount electrical box (System Sensor® PN SMB500) is available from Silent Knight. P/N 350288 Rev J Copyright©2015 Honeywell International Inc. -TO NEXT FROM PANEL OR DEVICE % /_�--._.— PREVIOUS DEVICE I 0 MONITOR $ $ ANY NUMBER OF UL LISTED CONTACT IM MODULE - CLOSURE DEVICES MAY BE USED.DO NOT MIX ' I CONNECT MODULES TO LISTED COMPATIBLE FIRE ALARM INTIATING,SUPERVISORY,OR 0 tO Q b I I CONTROL PANELS ONLY SECURITY DEVICES ON THE SAME MODULE. ° c 4011 $ I n l-1 � RESISTOR r 47K EOL III 111[1.1hT ELR-47K e a e• - ALL WIRING SHOWN IS SUPERVISED AND POWER LIMITED um no INITIATING DEVICE CIRCUIT(IDC)-NFPA STYLE B POWER LIMITED:450pA MAX.i 11 VDC MAX INSTALL CONTACT CLOSURE DEVICES PER MANUFACTURERS INSTALLATION INSTRUCTIONS. Typical Wiring for IDP-Monitor Module, NFPA Style B TO NEXT - FROM PANEL OR DEVICE - % 44°. —4°.—4.4.... PREVIOUS DEVICE MONITOR 0 I ANY NUMBER OF UL LISTED CONTACT MODULE Ell NI CLOSURE DEVICES MAY BE USED.DO NOT MIX /� CONNECT MODULES TO LISTED COMPATIBLE FIRE ALARM INTIATING,SUPERVISORY,OR c / O Q b I $ CONTROL PANELS ONLY SECURITY DEVICES ON THE SAME MODULE. v ® n I�' I I �_� T EOL RESISTOR IS >•a I INTERNAL ATH C .% 4,,.di TERMINALS 8&9 ---. ALL WIRING SHOWN IS SUPERVISED AND POWER LIMITED ow mi INSTALL CONTACT CLOSURE DEVICES PER MANUFACTURERS INSTALLATION INSTRUCTIONS. Typical Wiring for IDP-Monitor Module, NFPA Style D Specifications Environmental Physical Operating Temperature: 32°F— 120°F (0°C—49°C) Height: 4.5" (11.4 cm) Humidity: 10%—93% non-condensing Width: 4" (10.2 cm) Ordering Information Depth: 1.25" (3 cm) IDP-Monitor Monitoring Module Shipping Weight: 6.3 oz (196 g) Accessories Electrical SMB500 4" Square Surface Mount Electrical Box Operating Voltage: 15—32 VDC SLC Standby and Alarm Current Draw: 350 pA End-of-Line Resistance: 47K S Max. IDC wiring resistance: 1,500 f2 Max. IDC Voltage: 11 Volts Max. IDC Current: 450 pA SLC Loop Resistance: 40 f2 max. SILENT This document is not intended to be used for installation purposes.We try to keep our product information up-to- date and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are TO KNIGHT subject to change without notice. For more information,contact Silent Knight 12 Clintonville Road, Northford,CT 06472-1610 Phone:(800)328-0103,Fax:(203)484-7118. by Honeywell For Technical Support,Please call 800-446-6444. www.farenhyt.com *Th, SYSTEM SENSOR f : Outdoor Selectable- ` E R . E Output Horns, + Strobes, and (°tl, ir Horn Strobes for Wall Applications SPECTR1ert SpectrAlertKAdvance outdoor audible visible products a v a __ c E are rich with features that cut installation times and maximize profits. Features SpectrAlert Advance offers the broadest line of outdoor horns, • Weatherproof per NEMA 4X, IP56 strobes,and horn strobes in the industry.With white or red plastic • Listed to UL 1638(strobe)and UL 464(horn) housings,wall or ceiling mounting options,and plain or FIRE-printed devices,SpectrAlert Advance can meet virtually any application • • Compatible with System Sensor synchronization protocol and requirement,including indoor,outdoor,wet,and dry applications in legacy SpectrAlert products temperatures from—40°F to 151°F. • Field-selectable candela settings:15, 15/75,30,75,95, 110, 115, 135, 150, 177,and 185 Like the entire SpectrAlert Advance line,outdoor horns,strobes, • Automatic selection of 12-or 24-volt operation at 15 and and horn strobes for wall applications include a variety of features 15r75 candela that increase application flexibility and simplify installation.First, • Rotary switch for horn tone and three volume selections field-selectable settings,including candela,automatic selection of 12-or 24-volt operation,horn tones,and three volume options enable • Horn rated at 88+dBA at 16 volts installers to easily adapt devices to meet requirements. • Rated from—40°F to 151°F • Universal mounting plate with an onboard shorting spring that Next,SpectrAlert Advance devices use a universal mounting plate tests wiring continuity before devices are installed for both wall and ceiling applications.This mounting plate includes • Plug-in design with minimal intrusion into the back box an onboard shorting spring that ensures wiring continuity before • Tamper-resistant construction devices are installed,so installers can verify proper wiring without mounting the devices and exposing them to potential construction • Listed for ceiling or wall mounting damage.Once the plates are mounted,all SpectrAlert Advance devices utilize a plug-in design with a single captured screw to speed installation and virtually eliminate costly ground faults. Outdoor devices ship with weatherproof plastic back boxes(metal back boxes are available separately)that accommodate in-and- out wiring for daisy chaining devices.Plastic back boxes feature Agency Listings removable side flanges and improved resistance to saltwater corrosion.Knock-outs located on the back eliminate the need to drill SIGNALING Q holes for screw-in mounting.Plastic and metal weatherproof back 0 I 1 '1 boxes come with 3b-inch top and bottom conduit entries and 3A-inch MCEsA 7300,653e7(a door so-°nes) knock-outs at the back.A screw-in NPT plug with an 0-ring gasket LISTED approved 7125-1653:188(horn strobes, soon(c1 n,,non strobes,horns) •.P a o Pp clime strobes) for a watertight seal is included with each back box. 83593(outdoor and Merl strobes) 3023572 MEA452-05-E 7135-1653.1E9(horm.chimes) AV➢S115-02.12/3/2019•Page 1 SpectrAlert Advance Outdoor Horn,Strobe,and Horn StrobeSpecifications Architect/Engineer Specifications General SpectrAlert Advance outdoor horns,strobes,and horn strobes shall mount to a weatherproof back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate. Also,SpectrAlert Advance products,when used with the Sync•CircuitTM Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module,12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts.Outdoor SpectrAlert Advance products shall operate between-40 and 151 degrees Fahrenheit from a regulated DC or full- wave rectified unfiltered power supply.Strobes and horn strobes shall have field-selectable candela settings including 15, 15f75,30,75,95, 110,115,135,150, 177,and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL.The strobe shall be suitable for use in wet environments. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options shall be set by a multiple position switch. On four-wire products,the strobe shall be powered independently of the sounder.The horn or horn strobe models shall operate on a coded or non-coded power supply.The horn strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The horn strobe shall be suitable for use in wet environments. Physical/Electrical Specifications Operating Temperature -40°F to 151°F(-40°C to 66°C) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage with MLD3 Sync Module 8.5 to 17.5 V(12 V nominal)or 16.5 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions(including lens) 5.6"L x 4.7"W x 2.5"13(142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6"L x 4.7"W x 1.3"D(142 mm L x 119 mmW x 33 mm D) Wall-Mount Weatherproof Back Box Dimensions(SA-WBB) 5.7"L x 5.1"W x 2.0"D(145 mm L x 130 mm W x 51 mm D) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 15/75 cd. RVOS1I5U2.12/3/2019•Page 2 UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) UL Max.Horn Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela 15/75 142 148 77 81 Temporal Medium 44 49 58 69 Range 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non-Temporal High 57 56 69 75 95 NA NA 181 176 Non-Temporal Medium 42 50 60 69 ' 110 NA NA 202 195 Non-Temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 • Candela 150 NA NA 246 220 Coded Low 40 46 52 50 Range 177 NA NA 281 251 185 NA NA 286 258 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,Standard Candela Range(15-115 cd) 8-17.5 Volts 16-33 Volts DC Input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 ' Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,High Candela Range(135-185 cd) 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Candela Derating Horn Tones and Sound Output Data For K series products used at low temperatures,listed Horn and Horn Strobe Output(dBA) candela ratings must be reduced in accordance with 8-17.5 16-33 24-Volt Nominal this table. Switch Sound Volts Volts Reverberant Anechoic Strobe Output(cd) Position Pattern dB DC FWR DC FWR DC FWR DC FWR Listed Candela Candela rating at-40°F 1 Temporal High 78 78 84 84 88 88 99 98 15 2 Temporal Medium 74 74 80 80 86 86 96 96 15175 Do not use below 32°F 3 Temporal Low 71 73 76 76 83 80 94 89 30 4 Non- High 75 44 Temporal 82 82 88 88 93 92 100 100 95 70 5 Non- Medium 78 78 85 85 90 90 98 98 110 110 Temporal 115 115 6 Non- Low 75 75 81 81 88 84 96 92 135 135 Temporal 150 150 7t Coded High 82 82 88 88 93 92 101 101 177 177 8t Coded Medium 78 78 85 85 90 90 97 98 185 185 9t Coded Low 75 75 81 81 88 85 96 92 - tSettings 7,8,and 9 are not available on 2-wire horn strobe. SpectrAlert Advance Diagrams 119mm 64[r111 — a.7 1 2.5 . 1\ al 142mm I1) imo � pi Y Wall-Mount Horn Strobes Wall Plastic Weatherproof Back Box Wall-Mount Horn Strobe with Plastic • Weatherproof Back Box SpectrAlert Advance Ordering Information Model Description Red White Wall Horn Strobes P2RK P2WK 2-Wire Horn Strobe,Standard cd,Outdoor(includes plastic weatherproof back box) P2RK-P P2WK-P 2-Wire Horn Strobe,Standard cd,Outdoor,Plain(includes plastic weatherproof back box) P2RK-R P2WK-R 2-Wire Horn Strobe,Standard cd,Outdoor(does not include plastic weatherproof back box) P2RHK P2WHK 2-Wire Horn Strobe,High cd,Outdoor(includes plastic weatherproof back box) P2RHK-P P2WHK-P 2-Wire Horn Strobe,High cd,Outdoor,Plain(includes plastic weatherproof back box) P2RHK-R P2WHK-R 2-Wire Horn Strobe,High cd,Outdoor(does not include plastic weatherproof back box) P4RK P4WK 4-Wire Horn Strobe,Standard cd,Outdoor(includes plastic weatherproof back box) P4RK-R — 4-Wire Horn Strobe,Standard cd,Outdoor(does not include plastic weatherproof back box) P2RHK-120 — 2-Wire Horn Strobe,High cd,Outdoor,120 V(includes plastic weatherproof back box) Wall Strobes SRK SWK Strobe,Standard cd,Outdoor(includes plastic weatherproof back box) SRK-P SWK-P Strobe,Standard cd,Outdoor,Plain(includes plastic weatherproof back box) • SRK-R SWK-R Strobe,Standard cd,Outdoor(does not include plastic weatherproof back box) SRHK SWHK Strobe,High cd,Outdoor(includes plastic weatherproof back box) SRHK-P SWHK-P Strobe,High cd,Outdoor,Plain(includes plastic weatherproof back box) SRHK-R SWHK-R Strobe,High cd,Outdoor(does not include plastic weatherproof back box) Horns HRK — Horn,Red,Outdoor(includes plastic weatherproof back box) HRK-R — Horn,Red,Outdoor(does not include plastic weatherproof back box) Accessories SA-WBB SA-WBBW Metal Weatherproof Back Box WTP WTPW Metal Weatherproof Outdoor Flush-mounting Plate Notes: All-P models have a plain housing(no"FIRE"marking on cover). All-R models require metal weatherproof outdoor flush mounting plate or a metal weatherproof outdoor back box(order separately)."Standard cd"refers to strobes that include 15,15/75,30,75,95,110,and 115 candela settings."High cd"refers to strobes that include 135,150,177,and 185 candela settings.When replacing standard outdoor units both the device and back box must be replaced. f. SYSTEM 3825 Ohio Avenue•St.Charles,IL 60174 82019 System Sensor. Phone:800-SENSOR2•Fax:630-377-6495 Po specifications b eai ,t via'� >aorn �� SENSOR wwwsystemsensorcom for crrrrent product change evos115U2.12K82019 Far e n Ii y t For remote annunciation RA-100 Remote Annunciator The RA-100 Remote Annunciator can be used to operate and program the IFP-100 or IFP-1000 Fire Control Panels. The RA- 100's keypad and display match the built-in annunciator of the IFP- (DI 100 control panel. The remote annunciator connects to the control panel via the RS-485 system bus. When the system is in normal operation and has AC power, the Power LED is lit and all other LEDs are off. The other LEDs turn on as alarms, supervisories, troubles, system silenced and AC power losses occur. Features • 80-character backlit LCD display (4 lines with 20 characters each) • Tactile/audible feedback • Larger keypad buttons for system Reset and Silence iR A .4 4 • RS-485 interface to panel NI V • Can be flush- or surface mounted. Trim ring available for surface mounting. • Operation and appearance is identical to IFP-100 built-in • annunciator • Initiate and end fire drills with a single key press • View event history by alarms, supervisories, or troubles • Supports simultaneous use by multiple users from up to 8 separate RA-100s • on-board piezo sounder audibly indicates alarms, troubles, and • supervisories • Five Status LEDs for; alarms, supervisory, trouble, silence and AC power indications. • UL listed, complies with NFPA 72 • Wiring lengths up to 6000 ft. from the control panel Dimension Specifications Flush Mount: Operating Voltage: 24 VDC Outside wall: 12.25"W x 11.5"H x 7/8"D Standby Current: 20 mA (31.1 W x 29.2H x 2.2D cm) Inside wall: 9-3/8"W x 8-3/8"H x 2"D Alarm Current: 25 mA (23.8W x 21.3H x 5.1 D cm) Maximum Per System: 8 Surface Mount: Operating Temperature: 32° F to 120° F (0° C to 49° C) Including Trim Ring: 12.25"W x 11.5"H x 3"D Mounting: Surface or Flush (31.1W x 29.2H x 2.2D cm) Wiring Distance: Up to 6,000 feet from control panel Optional Accessories (depending on wiring method) RA-100TR Surface Mount Trim Ring 7550 Meridian Circle SILENT Maple Grove,Mn 55369-4927 763- 0/01 ItS KNIGHT 03-8 P/N 350389, 1-800-328-0103 Copyright©2001 Silent Knight Fax:763-493-7475 http://www.farenhyt.com Large Buttons for System Silence,Reset, Event Acknowledge, 80 Character LED Status and Fire Drill Indicators Display 1 Review Events Individually by,Alarms, _ Supervisories,or Troubles am .,4. 4. /4. , . A 4 , A Ergonomic Numeric Keypad Designed Keypad (Hidden when door is closed) (Hidden when door is closed) RA-100 Features IFP-1000 FACP jFP-100 FACP IL?1W own 0 RA-100 RA-100 RA-100 RA-WO RA-10C RA-100 IIIIIMI I -:11 . IR •Up to 8 RA-1O0s per system ► •Up to ft RA-100s per system , •6Ocharacter backlit LCD display •8Ocharacter backlit LCD display 14 lines with 20 characters each) (4 lines with 20 characters each) •Wiring lengths up to 6000 ft.from •Wiring lengths up to 6000 It.from the control panel the control panel SILENT 7550 Meridian Circle, Maple Grove, MN 55369-4927 fiti KNIGHT 1-800-446-6444 or in Minnesota 763-493-6435 FAX: 763-493-6475 World Wide Web: http://www.farenhyt.com Made in the U.S.A.