Loading...
Report ms124,24o-&PO/6 i/7g7 ski:el ! (3) RECEIVED SOILSOLUTIONS JAN 2 MO 3540 SE 28th Avenue Portland,Oregon 97202 ENV!RONMENtA, SERVICES CITY OE-WARD 503 234 2 8 '3UILDINGOIV SIGN Oregon 360.750.0 11 'BUILDING 7`tL,IJlV1� Ira Washington 360.750.0611 Fax 503.331.7133 Radon Mitigation System Installation wwwsoilsolutionsenvironmental.com December 19, 2019 Site Address: 11787 SW Wilton Ave Tigard,OR 97233 National Radon Proficiency Program (NRPP) licensed Soil Solutions personnel will design and install the radon mitigation system at the above referenced home. The system will be designed and installed in compliance with radon specific Environmental Protection Agency(EPA) standards. Soil Solutions will obtain the required mechanical permit and install the system to meet local building codes. Soil Solutions will leave the existing polyethylene vapor barrier membrane in place in the crawlspace and patch/install new 6 mil vapor barrier membrane where necessary, and at the discretion of Soil Solutions NRPP licensed personnel. Corrugated perforated pipe will be installed under the membrane and will be vented outside through a boring drilled in the north crawlspace wall. An in-line radon reduction suction fan will be connected to the suction piping and mounted on the outside of the home. The discharge piping will be routed up the north exterior wall and will terminate around and above the roof eave. If requested, Soil Solutions will also install new 6 mil vapor barrier in the crawlspace on top of the existing sheeting for an additional fee of$450.0.0. White Schedule 40 PVC piping material will be used for all suction and exhaust plumbing unless otherwise specified. A manometer will be installed on the suction pipe to monitor the operation of the system. The system will be appropriately labeled and the client will be provided with system documentation and operating instructions. Soil Solutions will contract a licensed electrician will connect the radon mitigation fan to an existing electrical circuit. The electrician will also install a power disconnect switch on the exterior wall of the home next to the radon fan. The licensed electrician will obtain the required electrical permit. Once the radon system is operational, there is potential for combustion appliances to back draft into the home. As a precaution,we will install a carbon monoxide detector in the home. If it is determined that combustion appliances back draft following the system installation, the client is responsible to hire a HVAC (heating, ventilation, air conditioning) contractor to address back drafting issues, and due to safety concerns, the radon mitigation system cannot be operated until remedied. It should also be noted that whenever combustion appliances are replaced or installed in the home in the future, discussion of back drafting issues should be addressed with the HVAC contractor. After the system has been activated, Soil Solutions will perform a short-term continuous monitor measurement to determine the system's initial effectiveness and will make system modifications, Page 1 of 2 RECEIVED (S) sOILSOLUTIONS 3540 SE 28th Avenue Portland,Oregon 97202 ENVIRONMENTAL SERVICES JAN 2 202C Oregon 503.234,2118 d''rY OF I$GARD Washington 360.750.0611 3UILDlNG DIVISION Fac 503.331.7133 Radon Mitigation System Installation 7 www,soilsolutionsenviranmentahcom December 19, 2019 Site Address: 11787 SW Wilton Ave Tigard, OR 97233 National Radon Proficiency Program (NRPP) licensed Soil Solutions personnel will design and install the radon mitigation system at the above referenced home. The system will be designed and installed in compliance with radon specific Environmental Protection Agency (EPA) standards. Soil Solutions will obtain the required mechanical permit and install the system to meet local building codes. Soil Solutions will leave the existing polyethylene vapor barrier membrane in place in the crawlspace and patch/install new 6 mil vapor barrier membrane where necessary, and at the discretion of Soil Solutions NRPP licensed personnel. Corrugated perforated pipe will be installed under the membrane and will be vented outside through a boring drilled in the north crawlspace wall. An in-line radon reduction suction fan will be connected to the suction piping and mounted on the outside of the home. The discharge piping will be routed up the north exterior wall and will terminate around and above the roof cave. If requested, Soil Solutions will also install new 6 mil vapor barrier in the crawlspace on top of the existing sheeting for an additional fee of$450.00. White Schedule 40 PVC piping material will be used for all suction and exhaust plumbing unless otherwise specified. A manometer will be installed on the suction pipe to monitor the operation of the system. The system will be appropriately labeled and the client will be provided with system documentation and operating instructions. Soil Solutions will contract a licensed electrician will connect the radon mitigation fan to an existing electrical circuit, The electrician will also install a power disconnect switch on the exterior wall of the home next to the radon fan. The licensed electrician will obtain the required electrical permit. Once the radon system is operational, there is potential for combustion appliances to back draft into the home. As a precaution,we will install a carbon monoxide detector in the home. If it is determined that combustion appliances back draft following the system installation, the client is responsible to hire a HVAC (heating, ventilation, air conditioning)contractor to address back drafting issues, and due to safety concerns, the radon mitigation system cannot be operated until remedied. It should also be noted that whenever combustion appliances are replaced or installed in the home in the future, discussion of back drafting issues should be addressed with the HVAC contractor. After the system has been activated, Soil Solutions will perform a short-term continuous monitor measurement to determine the system's initial effectiveness and will make system modifications, Page 1 of 2