Report �JPZU1i - C7300� SHREMSHOCK RECEIVED Architects&Engineers 7400 West Campus Rd. APR 2 4 2017 Suite 150 New Albany,OH 43054 CITY OF TIGARD t 614 545 4550 BUILDING DIVISION 888 373 4130 f 614 545 4555 www.shremshock.com REVISION DOCUMENT PROJECT BULLETIN No. 2 04/17/2017 White House I Black Market Washington Square Store#3219 9336 SW Washington Square Rd. Space#W13 Tigard, OR 97223 ARCH PROJECT No.: 160529.R02 To the Contractor: This bulletin, issued after the execution of the contract, describes proposed revisions of the contract documents and requests from contractor the amount of change, if any, in contract sum to accomplish the work described. It is assumed no change in contract time will be necessary unless contractor submits written request for time extension, including justification, with his proposal for work described in this bulletin. Except, as otherwise described herein, or as shown on drawings issued with this, current contract documents apply to proposed work. This bulletin is not an order to do work.After receipt and review of the proposal requested, a change order will be issued to authorize execution of the work, or portion thereof, if the owner so directs. REASON FOR REVISION: Client Comments Submit proposals for the change described herein on Contractor's letterhead. List each item individually as listed below. DRAWINGS INCLUDED WITH THIS BULLETIN: G1.2,AD.2, A1.1, A2.1, A3.1, A5.1, A7.1, A8.1, A8.2a, A8.2b,A8.2c,A8.3, S1.1, S2.1, S2.2, E1.0, E2.0, E3.0, E4.0&E6.0 DRAWING REVISION PROPOSALS: G1.2 RESPONSIBILITY SCHEDULE • Revised Ductwork, Air Device, and Temperature Control System Scope. • Revised Shopper Track and Security System Scope. • Added ACM panels to division 09 (Per Architectural Clarification) AD.2 REFLECTED CEILING DEMOLITION/LEASE PLAN • Added note for shopper trak to be removed & relocated per revised storefront A1.1 BARRICADE PLAN AND DETAILS • Revised storefront in plan 'A' and elevation 'L' per revised design • Updated banner graphics in elevation 'L' per revised storefront • Updated barricade in plan 'A' and elevation 'C' per revised storefront A2.1 CONSTRUCTION PLAN • Revised storefront in plan 'A' per revised design • Updated wall panel locations in sales area in plan 'A' per revised storefront • Added wall panels in sales area in plan 'A' per revised storefront A3.1 REFLECTED CEILING/LIGHTING PLAN • Revised storefront in plan 'A' per revised design • Updated lighting in display window and entry portal in plan 'A' per revised storefront • Relocated security dome, shopper trak and wireless access point in plan 'A' per revised storefront • Added R-4 fixture in sales area in plan 'A' per added wall panel • Revised shopper trak from existing to relocated in lighting fixture schedule in detail `M' • Updated and added display ceiling heights in plan 'A' per revised storefront A5.1 FINISH PLAN • Revised storefront in plan 'A' per revised design • Added wall panels in sales area in plan 'A' per revised storefront • Updated sales area flooring square footage per revised storefront A7.1 INTERIOR ELEVATIONS • Revised elevations 'A', 'B' & `C' per revised storefront A8.1 STOREFRONT PLAN AND ELEVATION • Issued new sheet per revised storefront design A8.2a STOREFRONT SECTIONS • Updated sections 'A' & 'J' per revised storefront design A8.2b STOREFRONT SECTION &DETAIL • Revised detail 'J' per revised storefront design • Replaced section `A' per revised storefront design A8.2c STOREFRONT SECTION • Updated section 'A' per revised storefront design A8.3 STOREFRONT DETAILS • Voided detail 'M' per revised storefront • Updated details 'A', `B', `E', 'G', `L', 'N' & 'P' per revised storefront S1.1 STOREFRONT PLAN &GENERAL NOTES • Revised storefront and framing in plan 'A' per revised storefront design S2.1 STOREFRONT SECTIONS • Revised framing in sections 'A' & 'J' per revised storefront design S2.2 STOREFRONT SECTIONS • Replaced section 'A' per revised storefront design 2of3 E1.0 ELECTRICAL POWER PLAN AND NOTES • Revised storefront receptacles and circuiting. • Relocated Access Point. • Relocated Shopper Track. • Relocated Security Dome. • Added Power Plan Coded Note#10. E2.0 ELECTRICAL LIGHTING PLAN, FIXTURE SCHEDULE AND NOTES • Added (1) 'R-4'fixture to perimeter display lighting circuit. • Revised storefront downlighting. • Added Storefront Box Sign. E3.0 ELECTRICAL DETAILS AND SYMBOLS • Removed circuits 'LA-21' and 'LA-27' from storefront contactor in Lighting Control Detail 'N'. E4.0 ELECTRICAL PANEL SCHEDULES& RISER DIAGRAM • Revised Panel `LA' Circuits#2, #14, #16, #21, #23, #25 and #27. E6.0 ENERGY CODE FORMS • Revised quantity of D2-LW and R-4C light fixtures. END OF REVISIONS Revised by: A. Wells(Arch), J. Holley (Elec), SMBH (Structral) 3of3 COMcheck Software Version 4.0.5.5 Interior Lighting Compliance 111.6 _ Certificate RECEIVED Section 1: Project Information APR 2 4 2017 Energy Code: 2014 Oregon Energy Efficiency Specialty Code CITY OF fIGARD Project Title:White House/Black Market Store#3219-Washington Square BUILDING DIVISION Project Type:Alteration Construction Site: Owner/Agent: Designer/Contractor: 9336 SW Washington Square Road Chico's Shremshock Engineering, Inc. Space#W13 11215 Metro Parkway 7400 W.Campus Rd. Portland,OR 97223 FT.Myers,FL 33966 Suite 150 New Albany,OH 43054 Section 2: Interior Lighting and Power Calculation A B C D Area Category Floor Area Allowed Allowed Watts (ft2) Watts/ft2 (B x C) Sales Area(Retail:Sales Area)(Ceiling Height 11 ft.) 1830 1.5 2745 Allowance:Furniture,clothing,cosmetics highlighting/Fix. ID: (E)F-LW 900(a) 1.4 810(b) Allowance: Furniture,clothing,cosmetics highlighting/Fix. ID: (E)F4 50(a) 1.4 70(b) Fiiting Room Area(Retail:Fitting Room):Exempt(Ceiling Height 11 ft.) Non-Sales(Warehouse:Medium/Bulky Material Storage):Exempt(Ceiling Height 11 ft.) Total Allowed Watts= 3625 (a)Area claimed may exceed total floor area when Retail Merchandise Highlighting allowance(s)are specified. (b) Allowance is(B x C)or the actual wattage of the fixtures given in Section 2,whichever is less. Area Category Exemption Qualifications Total Wattage Total Pm-Alt. #Fixtures Activity Area Pre-Alt. Post-Alt. Fixtures Repl./Added Fiiting Room Area(Retail:Fitting Room 300 sq.ft.): Exemption:Less 1320 912 22 2 than 10%fixture replacement. Non-Sales(Warehouse:Medium/Bulky Material Storage 692 sq.ft.): 845 845 13 0 Exemption: Less than 10%fixture replacement. Section 3: Interior Lighting Fixture Schedule A B C D E Fixture ID: Description/Lamp I Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D) Fixture Fixtures Watt. Sales Area(Retail:Sales Area 1830 sq.ft.) Compact Fluorescent 1:(E)B-LW/EM:8"Recessed Downlight:Triple 4-pin 42W: 2 25 42 1050 Electronic: Incandescent 5:(E)F-LW:7"Incandescent Downlight:Incandescent 45W: 1 18 45 810 Linear Fluorescent 1:(E)F4:4'Fluorescent Strip:48"T8 32W: Electronic: 2 2 65 130 HID 1:(R)D2-LW: Multi-Spot Recessed:Ceramic Metal Halide:Standard: 1 3 80 240 LED 1: R-1 C:6"LED Recessed Downlight: LED Other Fixture Unit 36W: 1 3 36 108 LED 1 copy 1:R-3C:6"LED Recessed Downlight: LED Other Fixture Unit 36W: 3 11 51 561 _ LED 1 copy 2: R-4C:6"LED Recessed Downlight: LED Other Fixture Unit 36W: 4 3 68 204 Fiiting Room Area(Retail:Fitting Room 300 sq.ft.):Exempt Non-Sales(Warehouse:Medium/Bulky Material Storage 692 sq.ft.):Exempt Total Proposed Watts= 3103 Section 4: Requirements Checklist Project Title: White House/Black Market Store#3219-Washington Square Report date:04/19/17 Data filename: P:1WHB1160529r2 WHB-Washington Square Tigard, OR104_Consultant Coord\MEP\CHl 160529 REV1.cck Page 1 of 3 In the following requirements,blank checkboxes identify requirements that the applicant has not acknowledged as being met. Checkmarks identify requirements that the applicant acknowledges are met or excepted from compliance. 'Plans reference page/section'identifies where in the plans/specs the requirement can be verified as being satisfied. Lighting Wattage: V 1. Total proposed watts must be less than or equal to total allowed watts. Allowed Wattage:3625 Proposed Wattage:3103 Complies: YES Mandatory Requirements: v 2. Exit signs. Internally illuminated exit signs shall not exceed 5 watts per side. Plans reference page/section: E2.0 v/ 3. Daylight zone control.All daylight zones are provided with individual controls that control the lights independent of general area lighting in the non-daylight zone. In all individual daylight zones larger than 350 sq.ft.,automatic daylight controls is provided.Automatic daylight sensing controls reduce the light output of the controlled luminaires at least 50 percent, and provide an automatic OFF control, while maintaining a uniform level of illumination.Contiguous daylight zones adjacent to vertical fenestration may be controlled by a single controlling device provided that they do not include zones facing more than two adjacent cardinal orientations(i.e., north,east, south,west).Daylight zones under skylights shall be controlled separately from daylight zones adjacent to vertical fenestration. Plans reference page/section: Daylighting not applicable I✓ 4. Interior lighting controls.At least one local shutoff lighting control has been provided for every 2,000 square feet of lit floor area and each area enclosed by walls or floor-to-ceiling partitions.The required controls are located within the area served by the controls or are a remote switch that identifies the lights served and indicates their status. Plans reference page/section: E2.0, E3.0 g/ 5. Sleeping unit controls.Master switch at entry to hotel/motel guest room. Plans reference page/section: Not applicable v 6. Egress lighting.Egress illumination is controlled by a combination of listed emergency relay and occupancy sensors to shut off during periods that the building space served by the means of egress is unoccupied. Plans reference page/section: E2.0 v 7. Additional controls. Each area that is required to have a manual control shall have additional controls that meet the requirements of Sections 505.2.2.1 and 505.2.2.2. Plans reference page/section: E2.0. E3.0 v 8. Light reduction controls.Each space required to have a manual control also allows for reducing the connected lighting load by at least 50 percent by either _ 1)controlling(dimming or multi-level switching)all luminaires;or 2)dual switching of alternate rows of luminaires,alternate luminaires,or alternate lamps;or 3)switching the middle lamp luminaires independently of other lamps;or 4)switching each luminaire or each lamp. Plans reference page/section: E2.0, E3.0 v 9. Buildings larger than 2,000 square feet are equipped with an automatic control device to shut off lighting in those areas.This automatic control device shall function on either: 1)a scheduled basis,using time-of-day,with an independent program schedule that controls the interior lighting in areas that do not exceed 10,000 square feet and are not more than one floor;or 2)an occupant sensor that shall turn lighting off within 30 minutes of an occupant leaving a space;or 3)a signal from another control or alarm system that indicates the area is unoccupied. Plans reference page/section: E2.0, E3.0 4./ 10.Occupancy sensors in rooms that include daylight zones are required to have Manual ON activation. Plans reference page/section: Daylighting Not Applicable 11 An occupant sensor control device is installed that automatically turns lighting off within 30 minutes of all occupants leaving a space. Plans reference page/section: E2.0 12Additional controls.An occupant sensor control device that automatically turns lighting off within 30 minutes of all occupants leaving a space or a locally activated switch that automatically turns lighting off within 30 minutes of being activated is installed in all storage and supply rooms up to 1000 square feet. Plans reference page/section: NonSales area exempt from Controls 13.Occupant override.Automatic lighting shutoff operating on a time-of-day scheduled basis incorporates an override switching device that: 1)is readily accessible,2)is located so that a person using the device can see the lights or the area controlled by that switch,or Project Title:White House/Black Market Store#3219-Washington Square Report date:04/19/17 Data filename: P:\WHB\160529r2 WHB-Washington Square Tigard,OR\04_Consultant Coord\MEP\CHI 160529 REV1.cck Page 2 of 3 so that the area being lit is annunciated,3)is manually operated,4)allows the lighting to remain on for no more than 2 hours when an override is initiated,and 5)controls an area not exceeding 2,000 square feet. Exception applies: In malls and arcades,auditoriums,single-tenant retail spaces,industrial facilities and arenas,the area controlled shall not exceed 20,000 square feet. Plans reference page/section: 14.Holiday scheduling.Automatic lighting shutoff operating on a time-of-day scheduled basis has an automatic holiday scheduling feature that turns off all loads for at least 24 hours,then resumes the normally scheduled operation. Plans reference page/section: E2.0(Existing Timeclock) ✓ 15.Exterior lighting controls. Lighting not designated for dusk-to-dawn operation shall be controlled by either a combination of a photosensor and a time switch,or an astronomical time switch. Lighting designated for dusk-to-dawn operation shall be controlled by an astronomical time switch or photosensor. Plans reference page/section: Not Applicable-Internal Mall ✓ 16.Tandem wiring.The following luminaires located within the same area shall be tandem wired: 1.Fluorescent luminaires equipped with one,three or odd-numbered lamp configurations,that are recess-mounted within 10 feet center-to-center of each other. 2.Fluorescent luminaires equipped with one,three or any odd-numbered lamp configuration,that are pendant-or surface-mounted within 1 foot edge-to-edge of each other. Plans reference page/section: E20 17.Medical task lighting or art/history display lighting claimed to be exempt from compliance has a control device independent of the control of the nonexempt lighting. Plans reference page/section: Not Applicable 18.Each dwelling unit in a building is metered separately. Plans reference page/section: Not Applicable Interior Lighting PASSES Section 5: Compliance Statement Compliance Statement: The proposed lighting design represented in this document is consistent with the building plans,specifications and other calculations submitted with this permit application.The proposed lighting system has been designed to meet the 2014 Oregon Energy Efficiency Specialty Code requirements in COMcheck Version 4.0.5.5 and to comply with the mandatory requirements in the Requirements Checklist. Reece A. Prather-P.E., Principal Name-Title Signature Date PRop tN Net, yip, C 78784PE Z &F O 14 ORE4,O2�N 6tQ� a91ci7 C' .4. PRP' ‘ EXPIRATION DATE:/ ,sib Project Title:White House/Black Market Store#3219-Washington Square Report date:04/19/17 Data filename: P:\WHB\1605292 WHB-Washington Square Tigard,OR104_Consultant Coord\MEP\CHI 160529 REV1.cck Page 3 of 3