REVISION DOCUMENT
PROJECT BULLETIN No. 2 04/17/2017
White House I Black Market
Washington Square
Store#3219
9336 SW Washington Square Rd.
Space#W13
Tigard, OR 97223
ARCH PROJECT No.: 160529.R02
To the Contractor:
This bulletin, issued after the execution of the contract, describes proposed revisions of the
contract documents and requests from contractor the amount of change, if any, in contract
sum to accomplish the work described. It is assumed no change in contract time will be
necessary unless contractor submits written request for time extension, including
justification, with his proposal for work described in this bulletin.
Except, as otherwise described herein, or as shown on drawings issued with this, current
contract documents apply to proposed work.
This bulletin is not an order to do work.After receipt and review of the proposal requested, a
change order will be issued to authorize execution of the work, or portion thereof, if the
owner so directs.
REASON FOR REVISION: Client Comments
Submit proposals for the change described herein on Contractor's letterhead. List each item
individually as listed below.
DRAWINGS INCLUDED WITH THIS BULLETIN: G1.2,AD.2, A1.1, A2.1, A3.1, A5.1, A7.1,
A8.1, A8.2a, A8.2b,A8.2c,A8.3, S1.1, S2.1, S2.2, E1.0, E2.0, E3.0, E4.0&E6.0
DRAWING REVISION PROPOSALS:
G1.2 RESPONSIBILITY SCHEDULE
• Revised Ductwork, Air Device, and Temperature Control System Scope.
• Revised Shopper Track and Security System Scope.
• Added ACM panels to division 09 (Per Architectural Clarification)
AD.2 REFLECTED CEILING DEMOLITION/LEASE PLAN
• Added note for shopper trak to be removed & relocated per revised storefront
A1.1 BARRICADE PLAN AND DETAILS
• Revised storefront in plan 'A' and elevation 'L' per revised design
• Updated banner graphics in elevation 'L' per revised storefront
• Updated barricade in plan 'A' and elevation 'C' per revised storefront
A2.1 CONSTRUCTION PLAN
• Revised storefront in plan 'A' per revised design
• Updated wall panel locations in sales area in plan 'A' per revised storefront
• Added wall panels in sales area in plan 'A' per revised storefront
A3.1 REFLECTED CEILING/LIGHTING PLAN
• Revised storefront in plan 'A' per revised design
• Updated lighting in display window and entry portal in plan 'A' per revised storefront
• Relocated security dome, shopper trak and wireless access point in plan 'A' per
revised storefront
• Added R-4 fixture in sales area in plan 'A' per added wall panel
• Revised shopper trak from existing to relocated in lighting fixture schedule in detail
`M'
• Updated and added display ceiling heights in plan 'A' per revised storefront
A5.1 FINISH PLAN
• Revised storefront in plan 'A' per revised design
• Added wall panels in sales area in plan 'A' per revised storefront
• Updated sales area flooring square footage per revised storefront
A7.1 INTERIOR ELEVATIONS
• Revised elevations 'A', 'B' & `C' per revised storefront
A8.1 STOREFRONT PLAN AND ELEVATION
• Issued new sheet per revised storefront design
A8.2a STOREFRONT SECTIONS
• Updated sections 'A' & 'J' per revised storefront design
A8.2b STOREFRONT SECTION &DETAIL
• Revised detail 'J' per revised storefront design
• Replaced section `A' per revised storefront design
A8.2c STOREFRONT SECTION
• Updated section 'A' per revised storefront design
A8.3 STOREFRONT DETAILS
• Voided detail 'M' per revised storefront
• Updated details 'A', `B', `E', 'G', `L', 'N' & 'P' per revised storefront
S1.1 STOREFRONT PLAN &GENERAL NOTES
• Revised storefront and framing in plan 'A' per revised storefront design
S2.1 STOREFRONT SECTIONS
• Revised framing in sections 'A' & 'J' per revised storefront design
S2.2 STOREFRONT SECTIONS
• Replaced section 'A' per revised storefront design
2of3
E1.0 ELECTRICAL POWER PLAN AND NOTES
• Revised storefront receptacles and circuiting.
• Relocated Access Point.
• Relocated Shopper Track.
• Relocated Security Dome.
• Added Power Plan Coded Note#10.
E2.0 ELECTRICAL LIGHTING PLAN, FIXTURE SCHEDULE AND NOTES
• Added (1) 'R-4'fixture to perimeter display lighting circuit.
• Revised storefront downlighting.
• Added Storefront Box Sign.
E3.0 ELECTRICAL DETAILS AND SYMBOLS
• Removed circuits 'LA-21' and 'LA-27' from storefront contactor in Lighting Control
Detail 'N'.
E4.0 ELECTRICAL PANEL SCHEDULES& RISER DIAGRAM
• Revised Panel `LA' Circuits#2, #14, #16, #21, #23, #25 and #27.
E6.0 ENERGY CODE FORMS
• Revised quantity of D2-LW and R-4C light fixtures.
END OF REVISIONS
Revised by: A. Wells(Arch), J. Holley (Elec), SMBH (Structral)
3of3
COMcheck Software Version 4.0.5.5
Interior Lighting Compliance
111.6
_ Certificate RECEIVED
Section 1: Project Information APR 2 4 2017
Energy Code: 2014 Oregon Energy Efficiency Specialty Code CITY OF fIGARD
Project Title:White House/Black Market Store#3219-Washington Square BUILDING DIVISION
Project Type:Alteration
Construction Site: Owner/Agent: Designer/Contractor:
9336 SW Washington Square Road Chico's Shremshock Engineering, Inc.
Space#W13 11215 Metro Parkway 7400 W.Campus Rd.
Portland,OR 97223 FT.Myers,FL 33966 Suite 150
New Albany,OH 43054
Section 2: Interior Lighting and Power Calculation
A B C D
Area Category Floor Area Allowed Allowed Watts
(ft2) Watts/ft2 (B x C)
Sales Area(Retail:Sales Area)(Ceiling Height 11 ft.) 1830 1.5 2745
Allowance:Furniture,clothing,cosmetics highlighting/Fix. ID: (E)F-LW 900(a) 1.4 810(b)
Allowance: Furniture,clothing,cosmetics highlighting/Fix. ID: (E)F4 50(a) 1.4 70(b)
Fiiting Room Area(Retail:Fitting Room):Exempt(Ceiling Height 11 ft.)
Non-Sales(Warehouse:Medium/Bulky Material Storage):Exempt(Ceiling
Height 11 ft.)
Total Allowed Watts= 3625
(a)Area claimed may exceed total floor area when Retail Merchandise Highlighting allowance(s)are specified.
(b) Allowance is(B x C)or the actual wattage of the fixtures given in Section 2,whichever is less.
Area Category Exemption Qualifications
Total Wattage Total Pm-Alt. #Fixtures
Activity Area Pre-Alt. Post-Alt. Fixtures Repl./Added
Fiiting Room Area(Retail:Fitting Room 300 sq.ft.): Exemption:Less 1320 912 22 2
than 10%fixture replacement.
Non-Sales(Warehouse:Medium/Bulky Material Storage 692 sq.ft.): 845 845 13 0
Exemption: Less than 10%fixture replacement.
Section 3: Interior Lighting Fixture Schedule
A B C D E
Fixture ID: Description/Lamp I Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D)
Fixture Fixtures Watt.
Sales Area(Retail:Sales Area 1830 sq.ft.)
Compact Fluorescent 1:(E)B-LW/EM:8"Recessed Downlight:Triple 4-pin 42W: 2 25 42 1050
Electronic:
Incandescent 5:(E)F-LW:7"Incandescent Downlight:Incandescent 45W: 1 18 45 810
Linear Fluorescent 1:(E)F4:4'Fluorescent Strip:48"T8 32W: Electronic: 2 2 65 130
HID 1:(R)D2-LW: Multi-Spot Recessed:Ceramic Metal Halide:Standard: 1 3 80 240
LED 1: R-1 C:6"LED Recessed Downlight: LED Other Fixture Unit 36W: 1 3 36 108
LED 1 copy 1:R-3C:6"LED Recessed Downlight: LED Other Fixture Unit 36W: 3 11 51 561
_ LED 1 copy 2: R-4C:6"LED Recessed Downlight: LED Other Fixture Unit 36W: 4 3 68 204
Fiiting Room Area(Retail:Fitting Room 300 sq.ft.):Exempt
Non-Sales(Warehouse:Medium/Bulky Material Storage 692 sq.ft.):Exempt
Total Proposed Watts= 3103
Section 4: Requirements Checklist
Project Title: White House/Black Market Store#3219-Washington Square Report date:04/19/17
Data filename: P:1WHB1160529r2 WHB-Washington Square Tigard, OR104_Consultant Coord\MEP\CHl 160529 REV1.cck Page 1 of 3
In the following requirements,blank checkboxes identify requirements that the applicant has not acknowledged as being met. Checkmarks
identify requirements that the applicant acknowledges are met or excepted from compliance. 'Plans reference page/section'identifies where in
the plans/specs the requirement can be verified as being satisfied.
Lighting Wattage:
V 1. Total proposed watts must be less than or equal to total allowed watts.
Allowed Wattage:3625 Proposed Wattage:3103
Complies: YES
Mandatory Requirements:
v 2. Exit signs. Internally illuminated exit signs shall not exceed 5 watts per side.
Plans reference page/section: E2.0
v/ 3. Daylight zone control.All daylight zones are provided with individual controls that control the lights independent of general area lighting
in the non-daylight zone. In all individual daylight zones larger than 350 sq.ft.,automatic daylight controls is provided.Automatic
daylight sensing controls reduce the light output of the controlled luminaires at least 50 percent, and provide an automatic OFF control,
while maintaining a uniform level of illumination.Contiguous daylight zones adjacent to vertical fenestration may be controlled by a
single controlling device provided that they do not include zones facing more than two adjacent cardinal orientations(i.e., north,east,
south,west).Daylight zones under skylights shall be controlled separately from daylight zones adjacent to vertical fenestration.
Plans reference page/section: Daylighting not applicable
I✓ 4. Interior lighting controls.At least one local shutoff lighting control has been provided for every 2,000 square feet of lit floor area and
each area enclosed by walls or floor-to-ceiling partitions.The required controls are located within the area served by the controls or are
a remote switch that identifies the lights served and indicates their status.
Plans reference page/section: E2.0, E3.0
g/ 5. Sleeping unit controls.Master switch at entry to hotel/motel guest room.
Plans reference page/section: Not applicable
v 6. Egress lighting.Egress illumination is controlled by a combination of listed emergency relay and occupancy sensors to shut off during
periods that the building space served by the means of egress is unoccupied.
Plans reference page/section: E2.0
v 7. Additional controls. Each area that is required to have a manual control shall have additional controls that meet the requirements of
Sections 505.2.2.1 and 505.2.2.2.
Plans reference page/section: E2.0. E3.0
v 8. Light reduction controls.Each space required to have a manual control also allows for reducing the connected lighting load by at least
50 percent by either
_ 1)controlling(dimming or multi-level switching)all luminaires;or
2)dual switching of alternate rows of luminaires,alternate luminaires,or alternate lamps;or
3)switching the middle lamp luminaires independently of other lamps;or
4)switching each luminaire or each lamp.
Plans reference page/section: E2.0, E3.0
v 9. Buildings larger than 2,000 square feet are equipped with an automatic control device to shut off lighting in those areas.This automatic
control device shall function on either:
1)a scheduled basis,using time-of-day,with an independent program schedule that controls the interior lighting in areas that do not
exceed 10,000 square feet and are not more than one floor;or
2)an occupant sensor that shall turn lighting off within 30 minutes of an occupant leaving a space;or
3)a signal from another control or alarm system that indicates the area is unoccupied.
Plans reference page/section: E2.0, E3.0
4./ 10.Occupancy sensors in rooms that include daylight zones are required to have Manual ON activation.
Plans reference page/section: Daylighting Not Applicable
11 An occupant sensor control device is installed that automatically turns lighting off within 30 minutes of all occupants leaving a space.
Plans reference page/section: E2.0
12Additional controls.An occupant sensor control device that automatically turns lighting off within 30 minutes of all occupants leaving a
space or a locally activated switch that automatically turns lighting off within 30 minutes of being activated is installed in all storage and
supply rooms up to 1000 square feet.
Plans reference page/section: NonSales area exempt from Controls
13.Occupant override.Automatic lighting shutoff operating on a time-of-day scheduled basis incorporates an override switching device
that: 1)is readily accessible,2)is located so that a person using the device can see the lights or the area controlled by that switch,or
Project Title:White House/Black Market Store#3219-Washington Square Report date:04/19/17
Data filename: P:\WHB\160529r2 WHB-Washington Square Tigard,OR\04_Consultant Coord\MEP\CHI 160529 REV1.cck Page 2 of 3
so that the area being lit is annunciated,3)is manually operated,4)allows the lighting to remain on for no more than 2 hours when an
override is initiated,and 5)controls an area not exceeding 2,000 square feet.
Exception applies: In malls and arcades,auditoriums,single-tenant retail spaces,industrial facilities and arenas,the area
controlled shall not exceed 20,000 square feet.
Plans reference page/section:
14.Holiday scheduling.Automatic lighting shutoff operating on a time-of-day scheduled basis has an automatic holiday scheduling feature
that turns off all loads for at least 24 hours,then resumes the normally scheduled operation.
Plans reference page/section: E2.0(Existing Timeclock)
✓ 15.Exterior lighting controls. Lighting not designated for dusk-to-dawn operation shall be controlled by either a combination of a
photosensor and a time switch,or an astronomical time switch. Lighting designated for dusk-to-dawn operation shall be controlled by
an astronomical time switch or photosensor.
Plans reference page/section: Not Applicable-Internal Mall
✓ 16.Tandem wiring.The following luminaires located within the same area shall be tandem wired:
1.Fluorescent luminaires equipped with one,three or odd-numbered lamp configurations,that are recess-mounted within 10 feet
center-to-center of each other.
2.Fluorescent luminaires equipped with one,three or any odd-numbered lamp configuration,that are pendant-or surface-mounted
within 1 foot edge-to-edge of each other.
Plans reference page/section: E20
17.Medical task lighting or art/history display lighting claimed to be exempt from compliance has a control device independent of the control
of the nonexempt lighting.
Plans reference page/section: Not Applicable
18.Each dwelling unit in a building is metered separately.
Plans reference page/section: Not Applicable
Interior Lighting PASSES
Section 5: Compliance Statement
Compliance Statement: The proposed lighting design represented in this document is consistent with the building plans,specifications and
other calculations submitted with this permit application.The proposed lighting system has been designed to meet the 2014 Oregon Energy
Efficiency Specialty Code requirements in COMcheck Version 4.0.5.5 and to comply with the mandatory requirements in the Requirements
Checklist.
Reece A. Prather-P.E., Principal
Name-Title Signature Date
PRop
tN Net, yip,
C
78784PE Z
&F O 14 ORE4,O2�N 6tQ� a91ci7
C' .4. PRP' ‘
EXPIRATION DATE:/ ,sib
Project Title:White House/Black Market Store#3219-Washington Square Report date:04/19/17
Data filename: P:\WHB\1605292 WHB-Washington Square Tigard,OR104_Consultant Coord\MEP\CHI 160529 REV1.cck Page 3 of 3