Detailed Submittal Schedule
Terminals
Tag VAV 3-3 VAV 3-4
1 2
Qty 1 1
Model SDVS SDVS
Size 1 6 6
Unit Size 6 6
Inlet Dia 6
Max Primary(CFM) 260 200
Min Primary(CFM) 80 60
Heat Min(CFM) 0 0
Downstream SP(in.w.g.) 0.25 0.25
Dis.H(in) 8.00
Dis.W(in) 12.00
Max Rad NC --
Terminal Liner FF50 FF50
Coil None None
Sequence 2000 2000
Aux/Fan/Mix(CFM) 0 0
Accessories 1 HB HB
Weight(Ibs) 12
C:\Users\keithh\AppData\Local\Temp\tmpFSAE.tm p
Page 1 of 1
v
IU1 I EM Performance Notes Date Printed: 1/31/2019
1. Dashes (--) indicate NC values less than 20.
2. NC values are calculated based on procedures outlined in AHRI Standard 885-2008, "A Procedure for Estimating Occupied
Space Sound Levels in the Application of Air Terminals and Air Outlets."
3. Sound power levels are given in decibels (dB).
4. Dashes (--) indicate sound power levels below 36-29-26-22-19-17 for each octave band; values below these sound power
levels are considered below significance per AHRI 880.
5. Minimum operating pressure is the minimum static pressure required to operate the terminal unit assembly at maximum
primary flow with a wide open damper.
6. Airflow is given in cubic feet per minute (cfm).
7. Air pressure drop is given in inches water gauge (in. w.g.), and water pressure drop is given in feet of water gauge (ft. w.g.).
8. NC values are derived from sound power levels obtained in accordance with ASHRAE Standard 130-2008 and AHRI
Standard 880-2011, which include duct end reflection corrections.
Page 1 of 1
SDV5 Single Duct Terminal' Unil
prieet Submittal Sheet Item Tag: VAV 3-3,VAV k
SDV5 Single Duct
L
uP
A—� (3) Vow o
1
Unit Size Max Airflow Outlet Inlet Length
B C A L
6 550 12 8 6 20 1/8
Digital Controls
'(1310AMPER SHAFT
3wu
NIULTI.POINT SENSOR '1 (95)
ituP • Controls are supplied by controls contractor and
A•413) ► oo 0 c� field installed
• Multi-point Primary Airflow Sensor supplied by
Price
8 2151).- .-r}
d0
{1111
Notes Liner FF50
• 22 Ga. zinc coated steel housing. Mechanically sealed and Internal Insulation - Fiber Free Foam 1/2" ( 13mm)thick, min. 1.5
gasketed, leak resistant construction lb/cu.ft density, meets requirements of NFPA90A and UL 181.
• Rectangular discharge opening with slip and drive cleat duct R-Value=2
connection
nOtISINL
INMSFAHATIOri
s"Das CERTIFIED,.
112^{73)
VG Tenn.u's
!NW SOaMa:O&°A
FOM IM611VAT10W
M
PROJECT: 5 LINCOLN-FARMERS SUBMITTAL NO: 258148-L SUBMITTAL DATE: 1/31/2019
ENGINEER: CUSTOMER: HUNTER-DAVISSON
DESCRIPTION: Single Duct-DDC By Others
SDV5//I/2000/6/FLD/CFM///0.0////////////FF50//H BI////II////I///IllhI///
)Copyright Price Industries 2019 All metric dimensions()are soft converted,Imperial dimensions are converted to metric and rounded to the nearest millimeter.
larketing Release version:2.19.1.2,All In One version:3.19.1 Information within this document is subject to change without notice.
SDV5 Single Duct Terminal Unii
p ham Submittal Sheet Item Tag: VAV 3-3,VAV 3
Hanger Bracket HB
Suggested HB Location
2..(51) / '2"( 2125JTYP O
41*
w, ll cr
to
'
ALTERNATE BRACKET LOCATION
IF INTERFERENCE WITH
SDV CONTROLS OCCURS
PROJECT: 5 LINCOLN-FARMERS SUBMITTAL NO: 258148-L SUBMITTAL DATE: 1/31/2019
ENGINEER: CUSTOMER: HUNTER-DAVISSON
DESCRIPTION: Single Duct-DDC By Others
SDV5//1/2000/6/FLD/C FM///0.0////////////FF50//H B///////////////////////
Copyright Price Industries 2019 All metric dimensions()are soft convened.Imperial dimensions are converted to metric and rounded to the nearest millimeter.
larketing Release version,2,19.1.2,All In One version:3.19.1 Information within this document is subject to change without notice.
r1FFrc,F copy
DF'lE RECEIVED
FEB 13 2019
CITY OF TIGARD
BUILDING DIVISION
Terminals
Submittals
Job Name: 5 LINCOLN - FARMERS
Job Location: PORTLAND, OR
Customer: HUNTER-DAVISSON
Date Printed: 1/31/2019
Spec Section: 15 - HVAC
Contact: 1500 NE SANDY BLVD
PORTLAND, OR 97232
Date Printed: 1/31/2019
Job Name: 5 LINCOLN - FARMERS
II c e. All-In-One
Detailed Submittal Schedule
Terminals
Tag VAV 3-3 VAV 3-4
1 2
Qty 1 1
Model SDV5 SDV5
Size 1 6 6
Unit Size 6 6
Inlet Dia 6
Max Primary(CFM) 260 200
Min Primary(CFM) 80 60
Heat Min(CFM) 0 0
Downstream SP(in.w.g.) 0.25 0.25
Dis.H(in) 8.00
Dis.W(in) 12.00
Max Rad NC --
Terminal Liner FF50 FF50
Coil None None
Sequence 2000 2000
Aux/Fan/Mix(CFM) 0 0
Accessories 1 HB HB
Weight(Ibs) 12
C:\Users\keithh\AppData\Loca I\Temp\tmpF5AE.tm p
Page 1 of 1
ce®
I I Performance Notes Date Printed: 1/31/2019
1. Dashes (--) indicate NC values less than 20.
2. NC values are calculated based on procedures outlined in AHRI Standard 885-2008, "A Procedure for Estimating Occupied
Space Sound Levels in the Application of Air Terminals and Air Outlets."
3. Sound power levels are given in decibels (dB).
4. Dashes (--) indicate sound power levels below 36-29-26-22-19-17 for each octave band; values below these sound power
levels are considered below significance per AHRI 880.
5. Minimum operating pressure is the minimum static pressure required to operate the terminal unit assembly at maximum
primary flow with a wide open damper.
6. Airflow is given in cubic feet per minute (cfm).
7. Air pressure drop is given in inches water gauge (in. w.g.), and water pressure drop is given in feet of water gauge (ft. w.g.).
8. NC values are derived from sound power levels obtained in accordance with ASHRAE Standard 130-2008 and AHRI
Standard 880-2011, which include duct end reflection corrections.
Page 1 of 1
SDV5 Single Duct Terminal Unii
price Submittal Sheet Item Tag: VAV 3-3,VAV 3
SDV5 Single Duct
1 AtiP 1
A-j"(3) :.row o C
Unit Size Max Airflow Outlet Inlet Length
B C A L
6 550 12 8 6 20 1/8
Digital Controls
03IDAMPER SHAFT
UITI.POINT SENSOR 3 MAX
• Controls are supplied by controls contractor and
.f3! AIR _,� c field installed
F ow �I I • Multi-point Primary Airflow Sensor supplied by
(' Price
rts»
011)
Notes Liner FF50
• 22 Ga.zinc coated steel housing. Mechanically sealed and Internal Insulation- Fiber Free Foam 1/2" ( 13mm)thick, min. 1.5
gasketed, leak resistant construction lb/cu.ft density, meets requirements of NFPA90A and UL 181.
• Rectangular discharge opening with slip and drive cleat duct R-Value =2
connection
Dui CERTIFIED-
.'6
bnW.4 IW1(Ft I51Y.'6
tattt.11
VAV ftli,m,o U
AR O SL21E7rC
raw WR&A
xy,yxc
PROJECT: 5 LINCOLN -FARMERS SUBMITTAL NO: 258148-L SUBMITTAL DATE: 1/31/2019
ENGINEER: CUSTOMER: HUNTER-DAVISSON
DESCRIPTION: Single Duct-DDC By Others
S D V 5//1/2000/6/F L D/C F M///0.0//////////I/F F50//H B////NIII/I/I////I/////
I Copyright Price Industries 2019 All metric dimensions()are soft converted.Imperial dimensions are converted to metric and rounded to the nearest millimeter.
larketing Release version:2.19.1.2.All In One version:3.19.1 Information within this document is subject to change without notice.
SDV5 Single Duct Terminal Unii
pri Submittal Sheet Item Tag: VAV 3-3,VAV 3
Hanger Bracket HB
Suggested HB Location
2' `h 1 '``... 1 ()1f._ 2"[25]TYP
? / ALTERNATE BRACKET LOCATION
IF INTERFERENCE WITH
SDV CONTROLS OCCURS
PROJECT: 5 LINCOLN-FARMERS SUBMITTAL NO: 258148-L SUBMITTAL DATE: 1/31/2019
ENGINEER: CUSTOMER: HUNTER-DAVISSON
DESCRIPTION: Single Duct-DDC By Others
SDV5//I/2000/6/F LD/C FM///0.0III///////IIFF 50//H B/I/////IIllllllllllllll
1 Copyright Price Industries 2019 All metric dimensions 0 are soft converted.Imperial dimensions are converted to metric and rounded to the nearest millimeter.
larketing Release version:2.19.1.2,All In One version:3.19.1 Information within this document is subject to change without notice.