Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Report
4 )52aT-60Cb, sti2Dsal OAK STREET APARTMENTS BUILDING B 8900 SW OAK STREET TIGARD OREGON 97223 RECEIVED SEP 4 2018 CITY OF TIGARD BUILDING DIVISION Emergency Voice Evacuation System battery&voltage-drop calculations, data sheets,and system drawing set. WVS Willamette Valley Security P.O.Box 1563 Sherwood OREGON 97140 503-244-5273 CCB 96932 r Fire Alarm Control Panel Battery Calculations Miain boards&PAD100 Devices model Qty standby total standby alarm total alarm fire alarm control panel IPA-4000 1 0.130000 0.130000 0.220000 0.220000 addressable loop expander SLCE-127 1 0.060000 0.060000 0.060000 0.060000 fire system annunciator 6500 1 0.020000 0.020000 0.050000 0.050000 manual alarm station PSSA 2 0.000200 0.000400 0.000200 0.000400 photoelectric smoke detector PD 36 0.000300 0.010800 0.000300 0.010800 heat detector HD 2 0.000300 0.000600 0.000300 0.000600 miniature monitor module MIM 0 0.000200 0.000000 0.000200 0.000000 monitor module sIM 0 0.000240 0.000000 0.000240 0.000000 dual input monitor module DIM 25 0.000240 0.006000 0.000240 0.006000 twin relay twin input module TRTI 2 0.000240 0.000480 0.000240 0.000480 duct smoke detector DuCTR 0 0.000500 0.000000 0.000500 0.000000 SLC expansion board SLCE-127 0 0.060000 0.000000 0.060000 0.000000 future 0 0.000000 0.000000 0.000000 0.000000 standby summary 0.228280 alarm sum 0.348280 standby time hours 24 panel total standby(AH) 5.4787 24VDC 24VDC 24VDC 24VDC 24VDC EVAC current device 11110/11"NAC model Qty Qty Qty Qty Qty Qty draw count strobe 15cd 5 0 0 0 0 0 0 0.042 0 strobe 30cd S 0 0 0 0 0 0 0.058 0 strobe 75cd S 0 0 0 0 0 0 0.116 0 strobe 110cd S 0 0 0 0 0 0 0.161 0 WP speaker-strobe WSS 0 0 0 0 0 0 0.176 0 speaker/strobe 15cd SPKSTR 0 0 0 0 0 0 0.078 0 speaker/strobe 30cd SPKSTR 0 0 0 0 0 0 0.096 0 speaker/strobe75cd SPKSTR 0 0 0 0 0 0 0.180 0 speaker/strobe 110cd SPKSTR 0 0 0 0 0 0 0.224 0 future 0 0 0 0 0 0 0.000 0 Auxililary relay MR201 1 1 1 1 1 0 0.030 5 0.030 0.030 0.030 0.030 0.030 0.000 0.1500 SLC&NAC Device harm 0.4983 Alarm Multiplied for 15 minutes alarm 0.2490 Total NAC Panel&Device Alarm(AH) 0.1241 Safety Factor Total System AH Total Standby Total Alarm Required AH Multiply by 1.2 Required Batteries Used le 5.4787 0.1241 5.6028 Times 1.2 6.7234 18AH Voltage-Drop Calculations(start voltage is 20.4 VDC,device operation range:16-33 VDC) total current draw 0.030 total current draw 0.030 24VDC 14 awg wire length in feet 185 24VDC 14 awg wire length in feet 400 1 St Floor voltage-drop 0.03408 2nd Floor voltage-drop 0.07368 voltage at last device 20.37 voltage at last device 20.33 total current draw 0.030 total current draw 0.030 24VDC 14 awg wire length in feet 415 24VDC 14 awg wire length in feet 430 3rd Floor voltage-drop 0.07644 4th Floor voltage-drop 0.07921 voltage at last device 20.32 voltage at last device 20.32 total current draw 0.030 total current draw 0.000 24VDC 14 awg wire length in feet 445 EVAC Trip 14 awg wire length in feet 10 5th Floor voltage-drop 0.08197 voltage-drop 0 voltage at last device 20.32 voltage at last device 20.40 seRemote Power Supply for Strobes Battery Calculations ( RPS ) Remote Power Supply Device model Qty standby total standby alarm total alarm Intelligent 10 amp NAC power supply PSN-1000 1 0.060000 0.060000 0.200000 0.200000 future 0 0.010000 0.000000 0.015000 0.000000 standby summary 0.060000 alarm sum 0.200000 RPSstandby time hours 24 panel total standby(AH) 1.4400 lie N1 N2 N3 N4 N5 N6 current device NAC model Qty Qty Qty Qty Qty Qty draw Count strobe 15cd S24 0 0 0 0 0 1 0.042 1 strobe 30cd S24 0 0 0 0 0 0 0.058 0 strobe 60cd S24 0 0 0 0 0 0 0.097 0 strobe 75cd S24 0 0 0 0 0 0 0.116 0 strobe 110cd S24 0 0 0 0 0 0 0.161 0 ceiling spkr/strb 30cd 24CLPW 0 0 0 0 0 1 0.096 1 speaker/strobe 15cd SPKSTR 1 8 8 8 8 2 0.078 35 speaker-strobe 30cd SPKSTR 0 0 0 0 0 2 0.096 2 speaker-strobe 75cd SPKSTR 0 0 0 0 0 0 0.180 0 speaker-strobe 110cd SPKSTR 5 0 0 0 0 2 0.224 7 WP Speaker/strobe WSSP 0 0 0 0 0 1 0.096 1 circuit sums 1.198 0.624 0.624 0.624 0.624 1.030 4.7240 Device Alarm 4.9240 Alarm multiplier for fifteen minutes Alarm 0.2490 Total NAC Panel&Device Alarm 1.2261 Safety Factor Total System AH Batteries Total Standby Total Alarm Required AH Multiply by 1.2 Required Used 100, 1.4400 1.2261 2.6661 Times 1.2 3.1993 7ah 1 Voltage-Drop Calculations(start voltage is 20.4 VDC, device operation range: 16-33 VDC) total current draw 1.198 total current draw 0.624 N1 14 awg wire length in feet 375 N2 14 awg wire length in feet 400 voltage-drop 2.7584 voltage-drop 1.53254 voltage at last device 17.64 voltage at last device 18.87 total current draw 0.624 total current draw 0.624 N3 14 awg wire length in feet 415 N4 14 awg wire length in feet 430 voltage-drop 1.59001 voltage-drop 1.64748 voltage at last device 18.81 voltage at last device 18.75 total current draw 0.624 total current draw 1.030 N5 14 awg wire length in feet 445 N6 14 awg wire length in feet 285 voltage-drop 1.70496 voltage-drop 1.8024 voltage at last device 18.70 voltage at last device 18.60 oI 100 Watt Speaker Amplifier ( 2 per EVAC Panel ) ii leBattery Calculations: Emergency voice evacuation control panel A B C D E F Device/Module Quantity of Standby Total Standby Alarm Total Alarm Model Number Device/Module Current(AMPS) Current Current Current ' BxC AMPS (BxE) Control Panet(s)&Modules: le EVAC PVX-100 1 0.1600 0.1600 1.1000 1.1000 zone splitter PVX-ZM 2 0.0510 0.1020 0.1300 0.2600 Sum Column for Standby Load(AMPS) 0.2620 Multiply by Required Standby Time(24 Hours) x 24 Tad Standby AH 6.288 Sum Column for Alarm Load(AMPS) 1.3600 Multiply by Required Alarm Time(15 Minutes) x 0.25 Total Alarm AH 0.340 TOTAL STANDBY TOTAL ALARM REQUIRED Al SAFETY FACTOR TOTAL SYSTEM Batteries (G) (H) (G+H) MULTIPLY x12 AH REQUIRED Used le 6.288 0.340 6.628 Times 1.2 7.95 I 12AH Speaker Tap Setting in Watts 1/8 1/4 112 1 2 speaker circuit 1 0 0 13 0 0 13 speaker circuit 2 14 23 0 0 0 i 1 37 speaker circuit 3 14 23 0 0 0 37 speaker circuit 4 14 23 0 0 0 37 speaker circuit 5 14 23 0 0 0 37 speaker circuit 6 0 0 2 0 0 2 speaker circuit 7 0 0 2 0 0 2 speaker circuit 8 0 0 5 0 0 5 speaker circuit 9 0 0 0 0 0 0 speaker circuit 10 0 0 0 0 0 0 speaker circuit 11 0 speaker circuit 12 0 Sub total devices 56 92 22 0 0 TOTAL WATTS sub total watts 7 23 11 0 0 34 Battery Calculations and Watt Draw IPA-4000• 8870020•REV A • 06/16 Device current draw reference sheets PSN-1000/PSN-1000(E)Battery Calculation Worksheet Complete one for all P-Link devices powered by the PSN-1000/PSN-1000(E) DStandby Total Mann Device TypeTotal Qty (mA) Standby (mA) Alarm (mA) (mA) PSN-1000/PSN-1000(E)Main Board 1 60 200 200 LCD Remote RA-6075R 20 25 lir LCD Remote RA-6500R/RA-6500F 20 50 PSN-1000/E Power Expander 15 15 LED-16/LED-16F P-Link 25 25 LED-Current(if applicable,see Note 6) 15 210 DRY-50 Driver Module 25 25 LED-Current(if applicable,see Note 6) 10 215 RLY-5 Relay Module 25 35 Relay Current(if applicable,see Note 6) 10 135 FCB-1000 Fire Communications Bridge 25 25 FIB-1000 Fiber Interface Bridge 30 30 SPG-1000 Serial Parallel Gateway 40 40 MC-1000 Multi-Connect Module 10 10 NAC 1 NAC 2 NAC 3 NAC 4 NAC 5 NAC 6 SLC Current Draw Total(ma) Total(ma) Convert to Amps x 0.001 Convert to Amps x 0.001 (*Refer to maximum allowable standby current)Total A: Total A: 60 minutes per hour Alarm time(minutes) Multiply by standby hours x- Example:5 minute alarm:enter 12 10 minute alarm:enter 6 Total Standby AH Total Alarm AH +Total Standby AH Total AH Efficiency Factor =0.85 Required AH *Maximum Allowable Standby Current Important Notes: (UL 24-Hour standby time) 1) FACP enclosure can house up to two(2) 18 AH batteries.Larger batteries require 7 AH .230 A accessory enclosure,part#SSU00500. 18 AH .619 A 2) NFPA 72 requires 24 hours of standby power followed by 5 minutes alarm activation. 33 AH 1.151 A 3) NFPA 12.12A requires 24 hours and five minutes of alarm activation. 55 AH 1.930 A 4) Door holder circuits configured to disconnect upon AC loss need not be included in the battery standby calculation since they will not draw power during that time. Door holders will contribute to standby current draw when AC is present. 5) Total current must not exceed power supply rating(10.OA). 6) LED/Relay current must be accounted for in the battery calculations for the supply source. 6-139 IPA-4000 • 8870020• REV A • 06/16 SLC#_ Current Draw Worksheet for PAD100-SLCEs(PAD Protocol) (Complete one for each configured PAD100-SLCE) 'total Total Standby Alarm Device TypeQty mA Standby Alarm ( ) (mA) (mA) (mA) PAD 100-SLCE Expansion Board(PAD protocol) 60 60 60 60 Photo detector(PAD I00-PD) .300 .300 1 Fixed heat detector(PAD 100-HD) .300 .300 CO detector(PAD100-CD) .300 .300 Combination photo/heat detector(PADI00-PHD) .300 .300 Duct detector(PAD100-DUCT) .300 .300 Duct detector w/relay(PAD I00-DUCTR)*Notes 4&5 .500 .500 Duct detector remote test switch(PADI00-DRYS) 10.0 15.0 Mini input module(PADl00-MIM) .200 .200 Speaker module(PAD100-SM) .240 .240 Pull station module single action(PADI00-PSSA) .200 .200 Pull station module dual action(PAD100-PSDA) .200 .200 Relay module(PAD I 00-RM) .240 .240 Notification appliance circuit(PAD I00-NAC)*Note 2 .200 .200 Twin relay-twin input module(PAD100-TRTI) .240 .240 1 Double input module(PAD100-DIM) .240 .240 One relay-one input module(PAD100-OROI) .240 .240 Zone module(PAD I00-ZM)*Note 1 .240 .240 Remote LED module(PAD100-LED) .240 .240 Remote LED w/Key(PAD100-LEDK) .200 .200 Single input module(PAD100-SIM) .240 .240 Addressable sounder base(PAD100-SB)*Note 3 .200 .200 Addressable replay base(PAD 100-RB) .200 .200 Isolator base(PAD100-IB) .150 .150 Isolator module(PAD I000-IM) .150 .150 SLC alarm LED Current n/a n/a n/a 36.0 SLC Standby SLC Alarm Current Current *Note 1:PAD100-ZM requires 24VDC power source.Standby Current= 15.0 mA.Alarm Current=60.0 mA. *Note 2:PADI00-NAC requires 24VDC power source.Standby Current=3.0 mA.Alarm Current=8.0 mA. *Note 3:PAD 100-SB requires 24VDC power source.Standby Current=4.0 mA.Alarm Current=30.0 mA. *Note 4:PAD I 00-DUCTR requires 24VDC power source.Standby Current=30.0 mA.Alarm Current=60.0 mA. *Note 5:When connecting the MS-RA/MSKA/P/R power source,Standby Current=45.0 mA.Alarm Current=90.0 mA. 4 6-140 P POTTER IPA-4000 The Symbol of Protection Fire Alarm Control Panel Features • 4,064 addresses available on this analog addressable system • Additional system capacity achieved via multi-point SLC modules • 1500 software zones • NFPA 72 Compliant Smoke Sensitivity Test Built-In °,„j • System Operates as Class A or Class B for SLC,P-Link and NACs • 10 Amp Power Supply,Expandable to 315 amps • 6 NACS,Regulated,Rated at 3 Amps each,expandable to 192 ' • • 4 Input/Output(I/O)Circuits for system flexibility rated at 1 Amp each, ideal for manual release and abort • Strobe Synchronization and System Wide Sync for Potter/AMSECO®, Gentex®,Cooper Wheelock®and System Sensor®strobes • Dedicated Alarm,Supervisory and Trouble Relays • 4,000 Event History Buffer • Cabinet will house up to 18 AH batteries • Optional two line DACT with liD-1000 that can report General,Zone or Point Information (311 • Built in IP communicator LISTED • Ethernet Pon for Programming and Network Connectivity • E-Mail System Status,Reports and Event Information • Product includes 5 year warranty Description Technical Specifications The IPA-4000 is an expandable analog/addressable releasing fire alarm Dimensions 18"hr"W x 27 Sha"H x 4'/i6"D system with a total system capacity of 4,064 addresses. Additional capacity on the system is achieved using multi-point SLC modules AC Mains SA Amps J 120 VAC 50/60 HZ The control panel utilizes the exclusive Potter protocol that includes a 3.0 Amps a.240 VAC 50/60 HZ complete line of sensors and modules.The system is expandable with a 16 gauge cold rolled steel with removable total of thirty-one additional addressable Signaling Line Circuits(SLC) Enclosure gn g locked door with Lexan viewing window each with a maximum of 127 devices.Each SLC may be comprised of any Standby Current-I 30 mA combination of smoke sensor,heat detectors or modules and allows for a total of 50 ohms of impedance and may use any wire compliant with the Alarm Current-200 mA National Electrical Code(NEC). • to Amps power for NACs,I/O,and P-Link Battery • 3 Amps per NAC,regulated The IPA-4000 has a 10 Amp power supply with six Notification • 1 Amp per I/O circuit,regulated Appliance Circuits (NACs) and four Input/Output (I/O) circuits. The • Battery Charger range 8-55 Ah NACs are rated at 3 Amps each and the I/Os are rated at 1 Amp each. • Battery Charger voltage 27.3 VDC Each output is regulated and power limited. in addition,each output is P-Link maximum current of I Amp uniquely programmable and may be configured for steady signal,strobe temperature and 32°to 120°(0°C to 49°C)with a maximum synchronization, constant power, door holder power, or releasing. The Humidity Range humidity of 93%non-condensing. strobe synchronization includes Potter/AMSECO,Centex,System Sensor and Cooper/Wheelock and w th the exclusive • NFPA 12, 12A, 13, 15,16, 17, 17A,70, Quadrasync each output may have a unique brand and all strobes will flash together.The 1/Os are 72,750,and 2001 designed for inputs such as manual release stations and abort switches that • ANSf UL 864-Local(L),Remote Sta- will not require polling and react nearly instantaneously. lion(RS),Central Station(CS),Propriety (PPU),Auxiliary(AUX).Type of Service: The IPA-4000 is listed for releasing of fire suppression systems. The Automatic(A),Manual(M),Water flow software allows cross zones,counting zones,and timers for suppression. Standards (WF)Sprinkler Supervisory(SS)Type of The system is capable of multiple release outputs across multiple hazards. Signaling:Digital Alarm Communicator In addition,the PSN-1000 may be used to extend releasing capability. (DAC),March Time(March),Non Coded The NACs may be expanded using the PSN-1000 series intelligent power (NC).Reverse Polarity(Rev Pol),Other supplies. Each PSN-1000 adds another 10 Amps of power;2 additional Technologies(OT) input circuits and the IPA-4000 will support up to 31 power supplies.The • IBC 2000,2003,2006,2009,2012 system will synchronize the strobes system wide. In addition,the PSN- 1000E has space to allow the installation of up to six PAD 100-SLCE SLC loop expansion cards.The cards mount on a stacker bracket that allows access to all SLC circuit connections. Potter Electric Signal Company, I.LC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com 8830102-REV A • 03/16 PAGE 1OF4 P POTTER IPA-4000v,, The Symbol of Protection Fire Alarm Control Panel SLC Loop Accessories The control panel may he connected with up to 4,064 addressable devices or modules in any combination.The SLC is not restricted by any special wire requirements and may he wired with any wire that complies with the NEC. SLC Loop Devices Device Description PAD100-PD Analog Photo Electric Smoke Detector is a smoke detector with a listed obscuration of 1.02 to 3.83 percent per foot. PADI00-PHD Combination Analog Photo Electric Smoke/Heat Detector—a smoke detector with a listed obscuration of 1.02 to 3.83 percent obscuration and a fixed temperature 135°Fahrenheit heat detector. PAD100-HD Analog Fixed Temperature Heat Detector that is selectable from 135°F to 185°F. PADl00-DUCTR Addressable Duct Smoke Detector with Form C Relay. PAD100-DUCT Addressable Duct Smoke Detector. PADl00-6B 6"round base that is mounted to an electrical box and wired for connection of one of the above sensors. PAD100-4B 4"round base that may be mounted to an electrical box and wired for connection to the above sensors. PAD100-IB Isolator base that interrupts a short in a SLC and prevents the short from affecting protected devices on the loop. PAD100-RB Addressable Relay Base that contains one relay controlled by the SLC.Relay is rated at rated at 2 amps at 30 VDC or 0.5A at 125 VAC. PAD 100-SB Addressable Sounder Base that contains an addressable sounder module that may be configured for local,group and all call. PAD100-CD Addressable CO gas detector. PAD 100-DD Addressable photo electric smoke detector for use in DUCT/DUCTR enclosure. Modules Device Description PAD100-MIM Micro Input Module provides a small foot print contact module for mounting inside an enclosure. PAD100-PSSA Single Action Addressable Pull Station. PADI00-PSDA Dual Action Addressable Pull Station. PAD100-SIM Single Input Module is a standard contact module with an LED that mounts into a 4"square electrical box. PAD100-DIM Dual Input Module is a device that can monitor two distinct inputs with a single device or in a Class A mode. PAD100-TRTI Two Relay Two Input module provides two form C relays that are individually controlled by the control panel Each relay is rated for 2 amps at 30VDC or 0.5 amps at I25VAC.Also provides two contact inputs. PAD100-NAC Notification Appliance Circuit module is an addressable remote appliance circuit controlled by the panel. PAD100-ZM Zone Module is used to connect conventional 2-wire smoke detectors to the system. PAD100-EM Module interrupts a short on the SLC and prevents the short from affecting protected devices on the loop. PAD100-RM Relay Module that provides one form C relay controlled by the control panel.Relay is rated for 2 amps at 30VDC or 0.5 amps at I 25VAC. PAD100-LED Module provides a single addressable LED that is controlled by the control panel. PAD100-SM Speaker Module provides switching for two audio channels. PAD 100-LEDK Addressable LED and key switch that mounts in a single gang box. PAD100-DRTS DUCTR Remote Test Switch that mounts in a single gang box and optionally supervised. PAD100-OROI One Relay One Input Module provides one form C relay and one input.The relay is rated at 2 amps at 30VDC or 0.5 amps at I 25VAC. Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com 8830102-REVA • 03/16 PAGE2OF4 P POTTER IPA-4000 The Symbol of Protection Fire Alarm Control Panel SLC Features RA-6075R—2 x 16 LCD annunciator with a key pad in a locked The Potter protocol is a digital protocol with a proven design for metal enclosure. reliability and noise immunity.The system does not require special RA-6500R(F)—4 x 40 LCD annunciator with a key pad in a locked cable or conductors for connection of the Signaling Line Circuit metal enclosure.Flush mount version available. as long as the cable is compliant with NFPA 70 and NFPA 72. LED-16(F)—16 LED annunciator with common indicators in a The system allows for Class A or Class B installations as well as locked metal enclosure. Flush mount version available. "T-Taps.'Each loop is capable of 127 points,with a max wiring PSN-1000(E)— 10 amp,remote intelligent power supply with distance of 10,000 ft. 6 NACs,2 I/Os and a P-Link repeater.This panel is listed in conjunction with the IPA-4000 as releasing circuits. Sensor Features CA-6500—Class A convertor that converts the SLC,NACs and The sensors through the fire alarm control panel provide a real P-Link connection time status as to the condition of the system.The smoke detector UD-1000—UL listed,Dual line telephone alarm communicator sensitivity,heat detector temperature level and drift compensation DRV-50—LED driver expander,used to connect up to 50 LEDs in a are all programmable options.The system also allows for a day/night graphic display mode where the panel automatically adjusts the sensitivity depending FCB-1000—Fire communication bridge,provides remote mounting on the time of day.To assist in the reduction of false alarms,the of the Ethernet connection smoke detectors also have a maintenance warning that sends a trouble signal when a detector is dirty to the point that it can no longer F1B-1000—Fiber interface module,used to extend P-Link to multi- maintain the programmed sensitivity, mode fiber(2 required) RLY-5—Relay module,provides 5 form C relay contacts rated at 3.0 User Interface amps 24VDC/l25AC SPG-1000—Serial parallel gateway,allows for the connection to a The fire alarm control panel has a 4 x 40 LCD display to provide status.The keypadserial or parallel printer information to the system has navigation keys to allow manipulation of the Menu on board the panel.The panel is The FIB-1000,FCB-1000 and the SPG-1000 may be installed in the shipped standard with the following LEDs: stacker bracket or ordered with the optional rack mount enclosure. • AC Power-Green MC-1000 Multi-Connect allows up to sixty-three IPA series panels to share a single reporting technology. • Alarm-Red AE-2—Two card expansion cabinet • Earth Fault-Amber AE-8—Eight card expansion cabinet • Supervisory-Amber AE-14—Fourteen card expansion cabinet • Silenced-Amber • Trouble-Amber Ethernet/LP. Connection The IPA-4000 is shipped standard with an Ethernet connection. • Pre-Release-Amber This connection is the programming port and may be connected • Release-Red to a building Wide Area Network(WAN)or Local Area Network (LAN).Once connected to the Internet,the panel may be selectively The common buttons include a Silence,Reset,Acknowledge,and Drill.All of the buttons are accessible once the locked door is programmed to e-mail alarm conditions,trouble conditions, opened. supervisory conditions,test,Event History and detector status.An e-mail may be sent to the panel and the panel will e-mail the event P-Link history,detector status,configuration file or server status to an authorized E-mail account.In addition,reminders may be set to send The IPA-4000 has a proprietary communication protocol that an e-mail for service,testing or other conditions. communicates through a RS-485 connection to field devices.Up to 64 devices may be connected to a single P-Link connection.The In addition,the Ethernet connection is Ut,listed as an IP P-Link includes the communication terminals and regulated 24 VDC communicator.The IP communicator is listed to report to the UL connection for the field devices.The field devices may be any of the listed Sur-Gard III IP receiver.The IP communicator replaces the following: traditional less reliable alarm communicator transmitter that utilized telephone lines.The IP communicator is an active method of PAD100-SLCE-Analog/Addressahle loop expansion module (maximum of 31 per IPA-4000) connection and communication to the monitoring station. Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com 8830102-REV A • 03/16 PAGE 3 OF 4 P POTTER IPA-4000 The Symbol of Protection Fire Alarm Control Panel v Dimensions 18.91" 17.60" 0 TOP a. I 4.41" 3.75" t r - DEPTH c 0 0 • 0 0 N Q I 0 I N 0 c 0 0 LEFT SIDE RIGHT SIDE • BOTTOM ° 0 Compatible Releasing Devices Note: For releasing applications please order the Potter EOLD Ordering Information (3005012)for circuits connected to a releasing solenoid or actuator. Model Description Stock No. Brand Description TPA-4000 Fire Alarm Releasing Control Panel 3992717 Skinner 73218BN4UNLVN0C112CZ 732 12BN4TNLVNOC322C2 Victaulic 753-E Series Mini Max MX123&MX200 w/8876677&889323 Viking 11591, 11601, 11602, 13843,& 13844 TLX PA0036 Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com 8830102-REV A • 03;16 PAGE 4 OF 4 Data Sheet NP SERIES - NP18 -121 Reliabilityis Security your Utilizing the latest advance design Oxygen 1 Recombination Technology, Yuasa have applied their 80 years experience in the lead acid battery - yare- 'l field to produce the optimum design of Sealed ra'%w Lead Acid batteries. "` ru►°' 4yy FEATURES • Superb recovery from deep discharge. • Electrolyte suspension system. • Gas Recombination. • Multipurpose: Float or Cyclic use. Terminals • Usable in any orientation. • Superior energy density. NP batteries are manufactured using a range of terminals which • Lead calcium grids for extended life. vary in size and type. Please refer to details as shown. • Manufactured World wide. an Operation in Orientation • Application specific designs. p Y The combination of sealed construction and Yuasa's unique Technical Features electrolyte suspension system allows operation in any orientation, with no loss of performance or fear of electrolyte Sealed Construction leakage. Yuasa's unique construction and sealing technique ensures no electrolyte leakage from case or terminals. Valve Regulated Design The batteries are equipped with a simple, safe, low pressure Electrolyte Suspension System venting system which releases excess gas and automatically All NP batteries utilize Yuasa's unique electrolyte suspension reseals should there be a build up of gas within the battery due system incorporating a microfine glass mat to retain the to severe overcharge. Note. On no account should the battery be maximum amount of electrolyte in the cells.The electrolyte is charged in a sealed container. retained in the separator material and there is no free General electrolyte to escape from the cells. No gels or other contaminants are added. Specifications Control of Gas Generation Nominal Capacity (Ah) NP18-12 The design of Yuasa's NP batteries incorporates the very latest oxygen recombination technology to effectively control the 20hr to 1.75vpc 30°C 17.2 generation of gas during normal use. 10hr to 1.75vpc 20°C 16 Low Maintenance Operation 5hrto1.70vpc20°c 14.5 Due to the perfectly sealed construction and the lhrto 1.60vpc20°C 10.3 recombination of gasses within the cell,the battery is almost Voltage 12 maintenance free. Energy Density(wh L2ohn 94 Specific Energy(Wh.kg.20hr) 38 Terminals Int.Resistance(m.Ohms) 11 Bolt fastened terminal E Maximum discharge(A) 112 2 0.1 Layout Short Circuit current(A) 500 .a-12 ,ozDimensions (mm) ss INCH 1 MM 2 1111 I F .472 12.00 Length 180 .453 11.50 \nMdth 76 NI ; N _ 433 11.00 O Q Height overall 167 — Terminal .216 5.50 �1 .079 2.00 weight(Kg) 6.2 Terminal E `- Layout 2 ii .I Terminal Torque Nm www.yuasabatteries.com NP SERIES - N P 18 -12 se iData% heetl Lead Calcium Grids Long shelf Life The heavy duty lead calcium alloy grids provide an extra margin The extremely low self discharge rate allows the battery to be of performance and life in both cyclic and float applications and stored for extended periods up to one year at normal ambient give unparalleled recovery from deep discharge. temperatures with no permanent loss of capacity. Long Cycle Service Life Operating Temperature Range Depending upon the average depth of discharge,over a The batteries can be used over a broad temperature range thousand discharge/charge cycles can be expected. permitting considerable flexibility in system design and location. Float Service Life Charge —15°C to 50°C The expected service life is five years in float standby Discharge—20°C to 60°C applications. Storage —20°C to 50°C(fully charged battery) Separators The use of the special separator material provides a very efficient SELF DISCHARGE CHARACTERISTICS insulation between plates preventing inter-plate short circuits 1%)IDS and prohibiting the shedding of active materials. PC 1322) CYCLIC RECHARGE REGIME L " y ire own BJE anew suweyc v. bD 03 ISO -I _..._.._--1) 2pT ) llme-1 TIms.21 IS 25 5 g y03 -G1C0 E CNrye Vdyse 10 0.15 ,-1 75 4 D - 4 0 12 15 is IS STORAGE THE(MONTHS) H0 D'1 50 CweMTrs Day '�` 3i5S 1�D'D'a 12 FLOAT CHARGE CHARACTERISTICS 0.06 - 25 „ Gnaw Cunard %3%a 0 D i�r.e i0 Vs 181,44 S� NP DISCHARGE CHARACTERISTICS li II14-1 025CA'2.275VPC CONSTANT VOLTAGE CHARGING M] I.CA, M AT20.C(88'F) CURVES AT 25 C (772F) 140 IN SiI lV) Nye C-ON.55.5It asa y we m earn INN..m N. 120 O.SS FOR 12V FOR eV d 2$0- 1 CFII.R4Ea VOWME 15L BATTERY BATTERY 110 BS NP AT 22C(I7`21 100 0)0 AO- - 110 CHARGE VOLTAGE Up 120- BD11• 0.19 1/, % IGO —AFTER 100DISCHARGE a ,1.0- y5 —` 0.1 AFTER SOYq$CHMGE e0 0A0_I 12A \\t uu azc.. 4 1Q0_ 6A U V 025 r p -____ CHARGING CURRENT 11.0 0 0.0- 42 ar. 0 2 +0`` 0 0 10 12 1.1 IS 10 20 CHARON.)THE MOORS) 60- 42 TYPICAL DISCHARGE CHARAC- - 1 ` 1 A15 IS w 2 A 0„1 20 TERISTICS NP RANGE MINUSES HOURS DISCHARGE INE CYCLE SERVICE LIFE IN RELATION FLOAT SERVICE LIFE NP RANGE TO DEPTH DISCHARGE CONDITIONS N4'DISCHARGE LGCHARGING CAR'RENT .09C Foss CHARGING OF DIS HRGEDC BAGW y ss CHARGING VOLUME:123%OF OIBLINROED CAPACITY (A){aA) TESThG LOSS TEMPERATURE VO TC.'.E -2]SVPC y Cr; AMBIENT TEMPERATURE:20'0 TO 2SC(SF TO T24) AA�)EHTTFMPERATUREa1'c y6`.TO T2F) i L0 120 No w 100>^ gg ,Th - —_____ ,„.,,,. t 80 J Epp% an DOO OOD O DISCHARGE IP 4D \ a7 20 2 yy 2 a¢ 0 1 2 3 4 ° two 1aw 6 5.6 1ne Hw eev 1dw LIEF(YEARS) NUMBER OF CYCLES 11F Yuasa Battery Inc. Distributed by 2901 Montrose Ave Laureldale, PA 19605 www.yuasabatteries.com Registered number 1548820 YUASA Cat.No. NP7-12 January 08 P POTTER RA-6500i The Symbol of Protection LCD Annunciator Features • Industry leading 4 line by 40 Character LCD • Common buttons for navigation • Common LEDs for status indication • 31 annunciator per panel • Maximum wire length of 6,500 feet • Available in 4 colors • Product includes a 5 year warranty ; (20 1•-.,. 1 LISTED Description Technical Spe ' s The RA-6500 is a LCD remote annunciator for the PFC-6000 series Standby Cturent 20 mA fire control panels. The RA-6500 communicates using a RS-485 connection to the main panel providing common indication of Alarms, Alarm Current 25 mA Supervisory,Trouble and other system status and control functions. Operating Temperature 0° -4 °C 2°F-120°F) The RA-6500 features a 4x40 LCD display with LED's for Power, l0%-93%(@J 30°C(86°F)non IAlarm, Supervisory, Trouble, and Silenced conditions. It can be Operating Humidity Range condensing humidity mounted on a single gang electrical box or a four square electrical box. Maximum Wire Length 6500 ft. The annunciator is enclosed in a sheet metal enclosure and has a Potter lock securing the keypad. Maximum Annunciators 31 Size(WxHxD) 10"x 7-7/8"x I-5/8" Wire Gauge 14 AWG-22 AWG Potter Electric Signal Company. LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com 8830113-REV A • 04/16 PAGE 1 OF 3 P POTTER RA-6500 The Symbol of Protection LCD Annunciator Installation The RA-6500 is connected to the PFC-6000 series fire control panels using a four wire RS-485 connection. The connection is power limited and supervised.Up to thirty-one(31)RA-6500 LCD annunciators can be connected using Class B or Class A wiring.Class A wiring requires an optional Class A Expander. RA-6500 Class B Wiring Example RA-6500 Class A Wiring Example Fig I Fig 2 To the next device Class A Expander O O O Camection 111h. P-IJNK Ii 0 m '' ° m - t A B '•° Ij ° a 0000 �j° Panel 0 0 O Panel (° P-LINK Connection Q 'Expansion Comeciion Q Expansion • B Device D-LIN C Device • • A B 1 hoa ° . ° I Enpansion 11 ° , Expansion Lkmce Device Address Settings The RA-6500 address is set by dip switch SI located on the back of the RA-6500.The address must be set in the range of 1 to 31 to be recognized by the control panel. RA-6500 Remote(Panel View) Fig 3 O �) ❑ O 0 �99�@9 0 drsvnrce O Dl' U O 0 DWG.veon-? Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com 8830113-REV A • 04/16 PAGE 2 OF 3 P POTTER RA-65001 The Symbol of Protection LCD Annunciator Dip Switch Settings Refer to the table below for dip switch settings per Annunciator Address. Annunciator Dip Switch Settings Annunciator Dip Switch Settings Address SW-1 SW-2 SW-3 SW-4 S\V-5 Address SW-1 SW-2 SW-3 SW-4 SW-5 1 On Olt' Off Off Ott 17 On Off Off Off On 2 Off On Off Off Off 18 Off On Off Off On 3 On On Off Off Off 19 On On Off Off On 4 Off Off On Off Off 20 Off Off On Off On 5 On Off On Off Off 21 On Off On Off On 6 Off On On Off Off 22 Off On On Off On 7 On On On Off Off 23 On On On Off On 8 Off Off Off On Off 24 Off Off Off On On 9 On Off Off On Off 25 On Off Off On On 10 Off On Off On Off 26 Off On Off On On II On On Off On Off 27 On On Off On On 12 Off Off On On Off 28 Off Off On On On 13 On Off On On Off 29 On Off On On On 14 Off On On On Off 30 Off On On On On 15 On On On On Olt 31 On On e On On On 16 Off Off Off Off On Ordering Information Model Description Stock No. RA-6500 LCD Annunciator-RED 3992660 RA-6500 LCD Annunciator-BLACK 3992744 RA-6500 LCD Annunciator-GRAY 3992745 RA-6500 LCD Annunciator-LIGHT GRAY 3992746 Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com 8830113-REVA • 04/16 PAGE3OF3 PAD100-PSSA/PSDA� PPO l l E ` Addressable Pull Station The Symbol of Protection Single/Dual Action Features • Single or Dual Action versions • Durable die-cast construction II QQ I ARM • Reset key matches the fire alarm control panels IRE L�11 4J't•^�' " • Compatible with IPA Series panels I` • SLC Class A,Class X&Class B LIF• Product includes a 5 year warranty p� PULL DOWN Ot P% • ()FoTTER ©pQTTER 111) LISTED Description Technical Specifications The PAD100-PSSA (Single Action) is activated by simply pulling Operating Voltage 24.0 VDC the white `•T" bar handle down. The PAD100-PSDA (Dual Action) is activated by lifting the front cover and then pulling the white "T" Max SLC Standby Curr 200uA bar handle down. Once activated,the`T"bar cannot be reset without Max SLC Alarm Curren. 200uA opening the front cover.Opening the front cover will also activate the 0 - t° • 49°C) pull station.To reset the PAD100-PS Series,use the Potter WS-93 key Environmental Limitation Indoor Only to unlock and open the front cover. Once the cover is open, push the "T"bar back into the normal position and re-secure the front cover. Dimensions 4.75"H x 3.25"W x 1.75"D Relative Humidity Range 0-93%(non-condensing) Application Single gang box or ive The PAD I 00-PSSA/PSDA is compatible with Potter's IPA series Mounting Options Potter P32-BB/DBR addressable fire alarm control panels. It is a non-coded addressable APS-SA-1.22 lbs. pull station available in either a single or dual action model and installs Shipping Weight on a single gang box or surface mounts using the P32-BB or P32-DBB AI'S-DA-1.46 lbs. (deep)back box. Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com 8830097-REV A • 03/16 PAGE 1 OF 2 ` P POTTER PAD100-PSSAIPSDA Addressable Pull Station" The Symbol of Protection Single/Dual Action Setting the Address The PADI00-PS Series uses one SLC address assigned to the device.The address is set using the DIP switch located on the back of the PAD I00-PS device. Pull Station Front View Fig I 7411.1rI [-.414,=-14-•_ Pce!O-i F rain do T PUltd ,.._ ___ ___ ..... ., eporrER PAD100-PSDA PADI00-PSSA I Pull Station Back View and Wiring Fig 2 iimm nIIIIPII o Varna azo MI) I i FACTORY WIRED CONTACTS FROM FACP OR / PREVIOUS DEVICE TO NEXT DEVICE Ordering Information Model Description Stock No. PAD100-PSSA Addressable Pull Station,Single Action 3992721 PAD I00-PSDA Addressable Pull Station,Dual Action _ 3992720 Potter Electric Signal Company. LLC • St. Louis, MO • Phone. 800-325-3936 • www.pottersignal.com 8830097-REV A • 03/16 PAGE 2 OF 2 P POTTER PAD100-PD The Symbol of Protection Photoelectric Smoke Sensor Features • Low profile,less than 2 inches with the base • Wide selectable sensitivity range of 1.0 to 3.7%/foot + 1 • Sensor communicates sensitivity to control panel4110 • UL listed smoke calibration and sensitivity • Optional locking tab to prevent unwanted removal I • Simple DIP switch address setting,no programming tool required • LED alarm indicator • Product includes a 5 year warranty (15/11 LISTED Description Technical Specifications The Photoelectric Smoke Sensor is a listed Analog Addressable smoke Operating Voltage 24 VDC sensor compatible with fire alarm control panels that utilize the Potter Addressable Device(PAD)protocol.The PAD100-PD is a low profile Alarm indicator 1 LED smoke sensor with a wide sensitivity range.The sensor and base(not Alarm set-point range 1.0 to 3.7%/tt 3.6-12%/m included)are made of a durable plastic in an off-white color to blend Installation temperature in with the ceiling. range 32 to 120°F/ 0 to 49°C The PAD 100-PD has a sensitivity range of 1.0 to 3.7%per foot and Operating relative ° is UL.The PAD100-PD features drift compensation and has built in humidity range 0%to 93%(Non-condensing) dirty detector warning as well as. The PAD100-PD and the control panel communicate over a proven and robust digital communication Start-up time Max. I sec. path and the system analyzes the information at the particular device. Maximum number of 127 The total polling speed is less than five(5)seconds,well under the UL addresses per loop requirements. Maximum number of The sensor is compatible with any of the PAD series sensor bases and lighted indicators in 30 simply twists on. The PAD100-PD is addressed using DIP switches alarm per loop. in the rear of the sensor and can be easily programmed in the field Color Eggshell White without special tools. Weight(without base) 101 g(3.56oz) Setting the Address Dimensions(without Fleight: 1.35 in(34mm) Each addressable device on the SLC loop must have a unique address base) Diameter:3.93 in(100 mm) from 1 to 127 to function properly. The address is set using DIP switches. Before connecting a device to the SLC loop, take the following precautions to prevent potential damage to SLC or device.Verify the following: 1. Power to the device is removed 2. Field wiring is correctly installed. 3. Field wiring has no open or short circuits. Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com 8830108-REV A • 03716 PAGE 1 OF 2 P POTTER PADI 00-PD The Symbol of Protection Photoelectric Smoke Sensor Air Velocity Ratings The PAD 100-PD has an Open Area of Protection air velocity rating of 0 to 300 feet per minute. The system has a maximum of 30 LEDs that can be turned on simultaneously.If the system already has 30 LEDs on,the PAD 100-PD will operate even though the LED may not illuminate, Operation The PAD 100-PD is an analog addressable sensor that uses one address on the Signaling Line Circuit(SLC)of a compatible fire alarm control panel. The unit communicates with the control panel as it is polled.The LEDs flash every time the unit is polled and they will latch steady if the unit is in an active status.The polling LED can be turned off if desired for less conspicuous operation. The PADI00-PD with the PAD100-4DB or PAD100-6DB has a low profile of less than two(2)inches to blend into the surrounding environment.The sensor includes an insect screen to prevent foreign objects from reaching the chamber and the can be cleaned to restore operation of a dirty detector. Sensor Sensitivity The PAD100-PD and the compatible control panel work in tandem to keep the sensitivity consistent.As the sensor is installed over time,the sensor compensates for the dirt in the unit until it is out of range.At that time,the panel will indicate a dirty sensor.The sensor will then have to he cleaned or replaced. The PAD100-PD can be programmed to provide a maintenance alert prior to reaching the dirty sensor level which will allow for intervention prior to the sensor going into trouble. This allows for sensor replacement or cleaning prior to a nuisance trouble occurs. NOTE:As required by NFPA,do not install the sensors until all construction is complete and the work area has been thoroughly cleaned.If the sensors have been installed in a construction environment,they should he cleaned or replaced before the system is placed into service. Spacing The PAD100-PD is UL listed with a recommended maximum spacing of 30 feet.Refer to NFPA 72 for specific information regarding detector spacing, placement and special applications. Compatible Bases All bases will mount on a single gang,double gang,octagon,4"square or mud ring electrical box. Device Description Stock No. PAD100-4DB 4"Standard Base 3992731 PAD100-6DB 6"Standard Base 3992732 PAD100-IB 6"base with an isolator module included. 3992730 PAD100-RB 6"base with one Form-C relay contact. 2A n 30VDC,0.5A @t 125VAC 3992728 PAD100-SB 6"base with sounder module included.Sound pattern is provided from external source. 3992729 Ordering Information Model Description Stock No. PAD I00-PD Photoelectric Smoke Sensor 3992733 Potter Electric Signal Company, LLC St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com arcing-REV A • 03/16 PAGE 2 OF 2 P POTTER PAD100-HD., The Symbol of Protection Heat Detector Features • Selectable Rate of Rise and/or Fixed Heat Detector • Low profile • Reliable detection technology • LED Alarm Indicator • Ambient temperature listing of 32°F to 150°F . • Simple DIP switch address setting,no programming tool required • Product includes a 5 year warranty LISTED Description Technical Specifications The PAD100-HD is a listed Analog Addressable rate of rise and/or Operating Voltage 24 VDC fixed temperature heat sensor compatible with any fire alarm control panel that has the Potter Addressable Device(PAD)protocol.The heat Alarm indicator I LED sensing portion utilizes a proven thermistor for accurate and reliable Alarm set-point range 135 to 185°F/57 to 85°C heat detection. The sensor and base (not included) are made of a Installation temperature durable plastic in an off white to blend in with the ceiling. ange 32 to 150°F/ 0 to 66°C rThe PAD100-HD is UL listed with a selectable fixed temperature Operating relative ° ° point from 135° to 185° Fahrenheit and can be used for rate of rise humidity range 0%to 93/o(Non-condensing) applications. See detector spacing limitations below.This flexibility allows the installer to cover a wide variety of applications with a single Start-up time Max. I sec. unit. Maximum number of 127 The PAD100-HD and the control panel communicate over a proven addresses per loop and robust digital communication path and the system analyzes the Maximum number of information at the particular device.The total polling speed is less than lighted indicators in 30 five(5)seconds,well under the UL requirements. alarm per loop The sensor is compatible with any of the PAD series sensor bases and Color Eggshell White simply twists on.The PAD100-HD is addressed using DIP switches Weight(without base) 82g(2.89 oz) in the rear of the sensor and can be easily programmed in the field Dimensions(without Height: 1.94 in(49mm) without special tools. base) Diameter 3.93 in(100mm) Setting the Address Each addressable device on the SLC loop must have a unique address from 1 to 127 to function properly. The address is set using DIP switches. Before connecting a device to the SLC loop, take the following precautions to prevent potential damage to SLC or device. Verify the following: 1. Power to the device is removed 2. Field wiring is correctly installed. 3. Field wiring has no open or short circuits. Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com 8830110-REVA • 03/16 PAGE 1OF2 P POTTER PAD100-HD The Symbol of Protection Heat Detector 1 Operation fhe PAD 100-HD is an analog addressable sensor that uses one address on the Signaling Line Circuit(SLC)of a compatible fire alarm control panel. The unit communicates with the control panel as it is polled.The LED flashes every time the unit is polled and will flash at a fast rate if the unit is in an active status.The polling LED can be turned off if desired for less conspicuous operation. The PAD100-HD with the PAD100-4DB or PAD100-6DB has a low profile to blend into the surrounding environment.The system has a maximum of 30 LEDs that can be turned on simultaneously. If the system already has 30 LEDs on,the PAD 100-HD will operate even though the LED will not illuminate. Spacing The ANSI/UL listed spacing limitations of PAD 100-HD smooth ceiling are dependent on alarm set point. Alarm Set-Point Rate of Rise Spacing Fixed Temperature Spacing 135°F to 160°F (57°C to 71°C) Max.70 ft. Max.70 ft. 161°F to 174°F Max.60 ft. Max.60 ft. (72°C to 79°C) 175°F to 185°F Max. 15 ft. Max. 15 tt. (80°C to 85°C) Compatible Bases All bases will mount on a single gang,double gang,octagon,4"square or mud ring electrical box. Device Description Stock No. PAD 100-4DB 4"Standard Base 3992731 PADI00-6DB 6"Standard Base 3992732 PAD 100-TB 6"base with an isolator module included. 3992730 PAD 100-RB 6"base with one Form-C relay contact. 2A 30VDC,0.5A I25VAC 3992728 PAD 100-SB 6"base with sounder module included.Sound pattern is provided from external source. 3992729 Ordering Information Model Description Stock No. PADI00-}ID Fixed Temperature Heat Sensor 3992735 Potter Electric Signal Company, LI.0 • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com 8830110-REV A • 03/16 PAGE 20F2 P POTTER PAD100-4DB/6DB The Symbol of Protection 4 /6"Addressable Detector Base Features • Terminals Marked with Polarity to assist with installation • Duplicate terminals for in and out SLC wiring >''' • Terminals accept 22 to 12 AWG wire sizes s ,4 • Installs on single gang,double gang,octagon or 4"square box • Locking tab prevents unauthorized detector removal *wa f ! t • Product includes S year warranty _ LISTED Application Technical Specifications The Potter PADI00-6DB and PAD100-4DB detector bases are used ve Single gang, double gang, octagon, and 4" to install Potter's addressable smoke and heat detectors.The PAD 100- Mounting Options square box 6DB will mount on a single gang.double gang,octagon or 4"square Terminals Screw-Clamp Type electrical box. Wire Guage 22 to 12 AWG Diameter 6.3 in(166 mm) Description Dimensions Height 0.72 in(18 mm) The PAD I00-6DB and PAD100-4DB are low-profile,surface mount Shipping Weight 87g(3.07 oz) bases used with Potter's addressable detectors.The base uses screw- clamp terminals that accept wire ranging from 22 to 14 AWG.When Material Durable Plastic installed on recessed electrical boxes the PAD 100-6DB is wide enough to completely cover the back box and the immediate surrounding area. The base is equipped with a locking tab to deter unauthorized removal of the attached detector. Potter Electric Signal Company, TLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com PRINTED IN USA R830107-REV A • 3116 PAGE OF 2 P POTTER PAD100-4DB/6DB " The Symbol of Protection 4 /6"Addressable Detector Base Locking Feature Wiring Diagram The PAD100-6DB and PADI00-4DB include a locking feature that Fig.3 prevents removal of the detector without using a tool. 1.To eliminate this feature,break off the locking tab(refer to Figure I),and then install the detector. ►- s+. 5+ Fig.1 Ti,F4CV First Detector Base Last Detector Base Loop(aLCj S �5- ii Il * t" Break otita(gray _.- ticking f disable Ordering Information locking feature eatum- Model Description Stock No. 2.To remove the detector from the base when the locking feature has PAD 100-6DB V 6"Sensor Base 3992732 been enabled, insert a small screw driver into the slot on the base to push the plastic tab while simultaneously turning the detector head PAD 100-4DB 4"Sensor Rase 3992731 counter-clockwise. Fig.2 Insert small screwdriver into slot to remove detector from hue. � i��� *frp ...........00/ ____....../ Ilt ....so/ Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com PRINTED IN USA 8830107-REV A • 3/16 PAGE 2 OF 2 P POTTER PAD100-DIM The Symbol of Protection Dual Input Module Features • Single module with dual contact monitoring inputs • Two(2)Class B or one(I)Class A monitoring inputs , • SLC Class A,Class X&Class B • Mounts in a standard 4"or double gang box • Wiring terminals accessible when mounted in box • All wiring terminals accept 22 to 12 AWG 4. ar. Pc • Product includes a 5 year warranty '1'. • '1 i/1 NOTE:This addressable module does not support 2-wire smoke detectors. • " rw„ M 0 LISTED Description Technical Sp - $ • ns The PAD100-DIM uses one (1) SLC loop address when monitoring Operating Voltage 24.OV two(2)Class B circuits or one(I)Class A circuit.The module mounts on either a 4" square or double gang box. The module is capable Max SLC Standby 240µA Current of monitoring two (2) separate class B circuits making it ideal for monitoring sprinkler waterfiow and valve tamper switches when they Max SLC Alarm 240 A are located in the same proximity.The PAD 100-DIM includes one red Current µ LED to indicate the module's status. In normal condition, the LED Max Wiring Resistan - flashes when the device is being polled by the control panel.When an of IDC input is activated,the LED w ill flash at a fast rate. Max Wiring 1 µF Capacitance of IDC Application EOL Resistor 5.IKS2 The PAD 100-DIM is compatible with Potter's IPA series addressable OOperating Temperature 32 to 120°F(0 to 49°C) fire alarm control panels. The PAD100-DIM is an interface module g e _ used to monitor dry contact devices such as sprinkler waterflow.valve OOperating Humidity 0 to 93%(non-condensing) tamper switches,or conventional pull stations.The module is capable ge of monitoring two separate Class B or one Class A circuits. Max no.of Module Per 127 units Loop Setting the Address 4.17"(106mm)Lx4.17" Dimensions Each addressable SLC device must be assigned an address. The (I06mm)W x 1.14"(29mm)D address is set using the DIP switch located on the PAD 100-DIM.When Standard 4"Square or the PAD100-DIM is used to monitor two individual Class B circuits Mounting Options Double Gang Box a single device address is assigned,each input is then identified as a sub-point of the module address. For example,if the address number Shipping Weight 0.61bs is assigned as "8", the first input will be "8.1"and the second input will be"8.2". Before connecting a device to the SLC loop, take the following precautions to prevent potential damage to the panel or device: 1. Power to the device is removed. 2. Field wiring is correctly installed. 3. Field wiring has no open or short circuits. Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com 8830082-REV A • 03/16 PAGE 1 OF 2 • P POTTER PAD1 00-DIM g The Symbol of Protection Dual Input Module 1 Installation Using Compatible Electrical Box Fig I kilt Qi` lc' 1 O -0 , Sri _ •.il Wiring Diagrams PAD100-DIM With One Class A Circuit Fig 2 ' 1OIJP 1M71' 1;HENa•CDPSWITCH 9'OSR171/ MMUS j FOR CAS A YIN& I.0 o nwcu5.nouc MICR IGa11G —Th +� • I i • . Oii9LU.11:13 1 PAD100-DI11 With Two Class B Circuits oca n..® ' czpa pride .oar.. aa.nv _ !I:1 • 7=famo Er 1110 'l' � i HinT171 V:::3 Ordering Information Model Description Stock No. PAD I 00-DIM Dual Input Module 3992703 Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com 8830082-REV A • 03/16 PAGE 2 OF 2 P POTTER PAD100-TRTI The Symbol of Protection Two Relay Two Input Module sir' Features • Single module with dual contact monitoring inputs • Two(2)Class B or one(I)Class A monitoring inputs • Two(2)Form C relay contacts • SLC Class A,Class X&Class B 100111 • Mounts in a standard 4"or double gang box • Wiring terminals accessible when mounted in box g, L_„� �7t ttr ° • All wiring terminals accept 22 to 12 AWG a •' j r • Product includes a 5 year warranty NOTE:This addressable module does not support 2-wire smoke w J detectors. •coo'" LISTED Description Technical Specifications The PAD100-TRTI uses one(1)SLC loop addresses when monitoring Operating Voltage 24.0V two(2)Class B circuits or one(I)Class A circuit.The PAD100-TRTI also provides two (2) Form C relay contacts. The module mounts Max SLC Standby Current 2400 on either a 4" square or double gang box. The module is capable of monitoring two (2) separate Class B circuits making it ideal for le Max SLC Alarm Current 240µA monitoring sprinkler waterflow and valve tamper switches when they are located in the same proximity. The PAD100-TRTI includes one Relay Contacts 2A C 30VDC,0.5A(&125VAC red LED to indicate the module's status.In normal condition,the LED Max Wiring Resistance of I00,Q flashes when the device is being polled by the control panel.When an IDC input is activated,the LED will flash at a fast rate. Max Wiring Capacitance of I µF IDC Application EOLResistor 5.lrcn The PAD I00=1'R1I is compatible with Potter's IPA series addressable Operating Temperature 32 to 120°F(0 to 49°C) fire alarm control panels.The PADI00=TRTI is an interface module Range used to monitor dry contact devices such as sprinkler waterflow. valve tamper switches,or conventional pull stations. The module is Operating Humidity Range 0 to 93%(non-condensing) capable of monitoring two separate Class B or one Class A circuits. The PAD I00-TRTI also provides two(2)form C relay contacts. Max no.of Module Per Loop 127 units Setting the Address Dimensions 4.17"(106mm)L x 4.17" (106mm)W x ].14"(29mm)D Each addressable SLC device must be assigned an address.The Standard 4"Square or address is set using the DIP switch located on the PADI00-TRTI.The Mounting Options Double Gang Box he PAD100-TRTI is assigned a single device address.each input and relay is identified as a sub-point of that single module address.For Shipping Weight 0.6 lbs example,if the address number is assigned as"8",the RLYI relay will be"8.1",the RLY2 relay will be"8.2,the B I input will be"8.3" and the 112 input will be"8.4". Before connecting a device to the SLC loop, take the following precautions to prevent potential damage to the panel or device: I. Power to the device is removed. 2. Field wiring is correctly installed. 3. Field wiring has no open or short circuits. Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com 8830080•REV A • 03/16 PAGE 1 OF 2 P POTTER PAD100-TRTI The Symbol of Protection Two Relay Two InputModuleV Installation Using Compatible Electrical Box Fig 1 /\� ,,,,,:,1 ,,,,, 41.0 1)1-11111r ® :.41 'vl ,.ill ® ` 1' `11 - Wiring Diagrams PAD100-TRTI With One Class A Circuit MO✓ETNE•CLA DIP SWROI - TO•urPOSRWN i 0. FOR CIASS A WIRING FROM FAA,OR - l— PREVIOUS MODULE \ . 11 TO NM'MODULE \ 211 '+i : ( rp n L. TWO Lp FOIMG .; rm. AYO:ROAM LA R1l C ��0 I� RN r - asiaLLrjrih - p aF 0 a 6) NOR NARBE,OLt ISNOT utcr.atAL® PA D100-TRTI With Two Class B Circuits TO r if-CD 0 ~ I� FORUMS SWING FROYRI�OIlNiN01AAlO0Uf Min ��II Gil 1111 7OTNEIORYOONi �M�.it i --n 'j; r' El in •- . ^ 1E11 IL1 : L- 04 MOP)FORM C MO-OF [r"] L• ICI WAY mxrACTs MOTOR Ye W Li in pan° ICI II*4005Rn _ I<-.J J ww..QL•' I Ao ik or HD R�IOI ----- OK aw NW IrFm-n NOTICE It is possible that the internal relay in the PAD 100-TRTI may be shipped in the non-normal/activated state.To ensure that the internal relay is set to the normal state,connect the module to the SLC loop and reset the control panel before terminating the wiring to the modules output. Ordering Information Model Description Stock No. PAD100-TRTI Two Relay Two Input Input Module 3992701 Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com SR30080-REV A • 03/16 PAGE 2 OF 2 P POTTER PAD100-RM The Symbol of Protection Relay Module Features • One(1)Form C relay contact • SLC Class A,Class X&Class B • Mounts in a standard 4"or double gang box • Wiring terminals accessible when mounted in box • All wiring terminals accept 22 to 12 AWG t , • Product includes a 5 year warranty tt o : 0 (211 LISTED Description Technical Specifications The PAD100-RM uses one (1) SLC loop address to provide one (1) Operating Voltage 24.0V Form C relay contact. The module mounts on either a 4" square or double gang box.The PAD100-RM includes one red LED to indicate Max SLC Standby 2400 the module's status. In normal condition, the LED flashes when the Current device is being polled by the control panel. Max SIC Alarm 240µA Current Application Relay Contacts 2A t730VDC,0.5A @r125VAC The PAD100-RM is compatible with Potter's IPA series addressable Operating Temperature 32 to 120°F(0 to 49°C) Range fire alarm control panels. The PAD100-RM is an interface module providing one(1)Form C relay contact. Operating Humidity 0 to 93%(non-condensing) Range Setting the Address Max no.of Module Per 127 units Each addressable SLC device must be assigned an address. The Loop address is set using the DIP switch located on the PAD100-RM.The Dimensions 4.17"(106mm)L x 4.17" PAD100-RM uses a single device address to identify relay contacts. (106mm)W x 1.14"(29mm)D Before connecting a device to the SLC loop, take the following Mounting Options Standard 4"Square or precautions to prevent potential damage to the panel or device: Double Gang Box I. Power to the device is removed. Shipping Weight 0.6 lbs 2. Field wiring is correctly installed. 3. Field wiring has no open or short circuits. Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com 8830084 -REV A • 03/16 PAGE I OF 2 P POTTER PAD100-RM The Symbol of Protection Relay Module l Installation Using Compatible Electrical Box Fig 1 II. r► I nlP,II o 0 tic�s �Arm, �. O Wiring Diagram PAD100-RM Relay Circuit Fig 2 CD ®i C FROM FACP OR PREVIOUS MODULE \ @@6I, ilr/ Nii» xo TO NEXT MODULE ![fill • xrc ONE())FORMC 0 o L„c c)1 RELAY CONTACTS a a a 0 l a o a *I to o a of 0 0® (( t h Lr� NOTICE It is possible that the internal relay in the PAD100-RM may be shipped in the non-nonnal/activated state.To ensure that the internal relay is set to the normal state,connect the module to the SLC loop and reset the control panel before terminating the wiring to the modules output. Ordering Information Model Description Stock No. PAD100-RM Relay Module 3992705 Potter Electric Signal Company, LLC • Sr Louis, MO • Phone: 800-325-3936 • www.pottersignal.com 8830084-REV A • 03/16 PAGE 2 OF 2 P POTTER PAM-1 The Symbol of Protection MULTI-VOLTAGE RELAY MODULE •Single SPDT relay with LED •Double-sided adhesive tape •Mounting screw !: .. • . \ • 12"leads L. 1 •6 wire nuts Power Requirements:Per position-0.015 Amps @ 24VDC,24VAC,115VAC Relay: UL recognized SPDT Contact Rating: 10 Amps a 115VAC 07• Amps @ 28VDC Stock number: 1000262 250 Microamps @ 5VDC AmbientTempeiatue: 32°F to 120°F(0°C to 49°C) Approvals: UL Listed Dimensions: 1.5"(38.1 mm)H x 1"(25.44 mm)W x 0.875"(222MM)D 12"(304.8mm)18 ga,wire leads Product Description The PAM-1 Relay is an encapulated 24VDC multi-voltage device These devices are ideal for applications where remote relays are providing 10.0 Amp form C contacts. The relay may be energized by required for control or status feedback. They are suitable for use with one of three input voltages:24 VAC,24 VDC,or 115 VAC. HVAC,temperature control,fire alarm,security,energy management, A red LED is provided which,when illuminated,indicates the relay and lighting control systems. coil is energized. The PAM-SD may be mounted by using the double-sided adhesive tape,the self-drilling screw,or loosely placed in an electrical backbox. Installation Wiring r RELAY ENERGIZED LED (_� N N WFA.__ BLUE 10 AMP H NC. CONTACTS '� ORG NO 115VACO;0.015A 24 VAC(43 0.015A ........_- 24 VDC @ 0.015 A Potter Electric Signal Company•2081 Craig Road,St. Louis,MO,63146-4161 • Phone:800-325-3936/Canada 888-882-1833•www.pottersignal.com PRINTED IN USA MFG.45401102-REV C PAGE 1 OF 1 9/07 P POTTER PSN-1000(E) The Symbol of Protection POWER EXPANDER Features • 10 Amp Power Supply 3 Amps,regulated per NAC • 6 NACs Class B or 3 NACs Class A • 2 dry contact inputs • Fully programmable and monitored through control panel • Isolated P-Link repeater connection,Class A or B • Up to 31 power supplies per control panel with system wide sync • Quadrasync feature synchronizes strobes from Potter/AMSECO, Gentex,Cooper-Wheelock and System Sensor. PSN-1000 • Compatible with all Potter PFC-6000 series fire alarm control panels. ()POTTERr o on Power Supply Electrical Specs • 120/240 VAC Input at 50/60 HZ Standby Current 60 mA • Alarm Current 200 mA S2930 7165-0328: 0198 Product includes a 5 year warranty Description The PSN-1000 series is a UL listed intelligent 10 amp notification power supply and P-Link(RS-485)repeater.The power supply connects to the P-Link bus from the control panel and is operated and supervised from the panel.The power supply may be installed 6,500 feet from the control panel.The PSN-1000 then repeats the P-Link communication for another 6,500 feet. The power supply has six(6)Class B or three(3)Class A power outputs.Each output is regulated and power limited with a 3 Amp maximum rating.In addition,the PSN-I000 has two(2)programmable dry contact inputs.The dry contact inputs are Class B,supervised inputs. The power supply operates on either 120 or 220 VAC power and has a regulated 24 VDC output.In addition,the panel can charge up to 55 AH batteries and will house 18 AH batteries.The cabinet is constructed out of 18 gauge cold rolled steel with a durable red powder coat finish.A standard Potter key lock is provided for securing the door.Electrical conduit knockouts are provided on the sides and top providing installers with multiple options for installing conduits and providing proper power separations. The PSN-I000 is a self contained intelligent power supply/P-Link repeater complete with cabinet.The PSN-1000E is the intelligent power supply/P-Link repeater with additional cabinet room for the exclusive Stacker Bracket for SLOE-127 loop expanders.Both cabinets include space for 18 AH batteries. The power supplies are programmed and controlled through the main control panel P-Link bus.The panel displays any troubles or off normal conditions of the power supply and the events are stored in the panel history buffer, Each output can be independently configured to provide one of four synchronization patterns,constant power,ANSI temporal Code 3 or Door Holder power.The panel can be configured to synchronize Potter/AMSECO®,Gentex®,Cooper Wheelock®and System Sensor®. Potter Electric Signal Company,LLC•St.Louis,MO•Cost Service:866-956-1211•Tech Support:866-240-1870•Canada:888-882-1833•www pottersignal.com PRINTED IN USA MFG.0830032-REV A PAGE I OF 2 05/12 P POTTER PSN-1000(E) The Symbol of Protection POWER EXPANDER 1 18.91" 17.60" O 0 0 E TOP . immiiiiiii r 4.41" 3.75" I r DEPTH . 0 I . Q _ O Q N N 0 I CO I N ® 1 0 0, 1 1 LEFT SIDE RIGHT SIDE 41 BOTTOM . o Dimensional drawings showing the cabinet in all three planes. Knock out locations. PRINTED IN USA MFG.48830032-REV.A PAGE 2 OF 2 05/I2 Data Sheet NP SERIES - N P 7 -12 Reliability is your Security ______________________ Utilizing the latest advance design Oxygen Recombination Technology, Yuasa have applied their ,�►�,t---2.---._ 80 years of experience in the lead acid battery field to "' INPF ..0.„40-01 produce the optimum design of Sealed Lead Acid rasa ... - batteries. f FEATURES --- """ • Superb recovery from deep discharge. • Electrolyte suspension system. Terminals • Gas Recombination. NP batteries are manufactured using a range of terminals • Multipurpose: Float or Cyclic use. which vary in size and type. Please refer to details as • Usable in any orientation • Superior energy density. shown. • Lead calcium grids for extended life. Operation in any Orientation • Manufactured World wide. The combination of sealed construction and Yuasa's • Application specific designs. unique electrolyte suspension system allows operation in Technical Features any orientation,with no loss of performance or fear of Sealed Construction electrolyte leakage. Yuasa's unique construction and sealing technique Valve Regulated Design ensures no electrolyte leakage from case or terminals. The batteries are equipped with a simple, safe low Electrolyte Suspension System pressure venting system which releases excess gas and All NP batteries utilize Yuasa's unique electrolyte suspension automatically reseals should there be a build up of gas system incorporating a microfine glass mat to retain the within the battery due to severe overcharge. Note. On no maximum amount of electrolyte in the cells.The electrolyte is account should the battery be charged in a sealed retained in the separator material and there is no free container. electrolyte to escape from the cells. No gels or other General Specifications contaminants are added. Control of Gas Generation Nominal Capacity (Ah) NP7-12 The design of Yuasa's NP batteries incorporates the very latest Layout 20hr to 1 .75vpc 30°C 7 oxygen recombination technology to effectively control the 1 Ohrto 1 .75vpc20°C 6.4 generation of gas during normal use. 4 Q 5hrto 1.70vpc20°C 5.9 Low Maintenance Operation 1 hr to 1 .60vpc 20°C 4.2 Due to the perfectly sealed construction and the O Voltage 12 recombination of gasses within the cell,the battery is Energy Density min L zohh 91 almost maintenance free. Specific Energy(wh.kg.20hp 32 Terminals Int. Resistance(m.Ohms) 25 Maximum discharge(A) 40/75 Faston tab' 187 A Faston tatc 250 D Short Circuit current(A) 210 Dimensions (mm) US.o°a o2� iN i=MM �z�••m� 929 JNf N=NA7 "ll�. .2s0 6.35 .31n 7.90 Length 151 .185 4,70 .250 6.35 Width 65 BEM y — .124 3.15 .16 4.0 h .698 2.50 031 0.6 Height overall 97.5 .059 1.50 s i I .020 0.5 Weight(Kg) 2.65 .031 0.80 -' .004 0.10 - Terminal AID °3r ��=0°^ Layout 4 Terminal Torque Nm - www.yuasabatteries.com NP NPSERIES - NP7 -12 1 Data Sheet Lead Calcium Grids Long shelf Life The heavy duty lead calcium alloy grids provide an extra margin of The extremely low self discharge rate allows the battery to be performance and life in both cyclic and float applications and give stored for extended periods up to one year at normal ambient unparalleled recovery from deep discharge. temperatures with no permanent loss of capacity. Long Cycle Service Life Operating Temperature Range Depending upon the average depth of discharge,over a thousand The batteries can be used over a broad temperature range discharge/charge cycles can be expected. permitting considerable flexibility in system design and location. Float Service Life Charge — 15°C to 50°C The expected service life is five years in float standby applications. Discharge—20°C to 60°C Separators Storage —20°C to 50°C (fully charged battery) The use of the special separator material provides a very efficient insulation between plates preventing inter-plate short circuits and SELF DISCHARGE CHARACTERISTICS prohibiting the shedding of active materials. (0),00 - CYCLIC RECHARGE REGIME T,`�_® q.ACi.yy, BMhLCNrq i 0.2 1E0 4 • • 11 T o 601.11%1.1.141111 _ z 30 u -tlw— . CREAM AMA. —1S i. 25 Gomm Tp pp" —12 9 0 9 IS IS 19 "0A1CA^ps STORAGE TIME(MONTHS) 9L! _ `A"°`wy" ,o FLOAT CHARGE CHARACTERISTICS 0 0 ,*,. Y NP DISCHARGE CHARACTERISTICS i gg"'1a a CURVES AT 25°C (772F) 5 01§ 0.Y'RA-2.2SSVPC CONSTANTVOLTAGE CHARGIN n( NCA) M AT20'C(ern (FORNI 12V 0OREV Nome:C.GNen capacity assIale0 on AAA Haneryln All1W M BATTERY BATTERY Or 14.0 qb NP AT arc(ITF) 120 100 1V0 74X,• IIIIIIIIIIIkillij00 gm .,,, / L1W16EYRrAGE ua t,,0- 55 , C0 •.b- 1 .........AFTER,00%OlSOMSOE 192 O , 610 , ___,µTER 50%CISORSOE 10.0- SA .0 800-I' MO 3 Ilir 20 OAE I r 4.0' 15 350, __ 0444044 CURRENT t,A 0 0 0 I 1 ` 0 • t0 12 11 16 b A 6A- aA ' . C„AROY10 Tpa[111G)REl 1 • N „IU TYPICAL DISCHARGE CHARAC- t NWUTES DISCHARGE-HMS HO0R5 TERISTICS NP RANGE CYCLE SERVICE LIFE IN RELATION FLOAT SERVICE LIFE NP RANGE TO DEPTH OF DISCHARGE TESTING CONDRICNS:DISCHARGE CURRENT:O.IYC Amp.(EN 1.NKELL CHARGING CURRENT 0.09C Mp (AH-A) TESTING CONDITIONS:FLOATING VOLTAGE: 2315VPC CHARGING VOLUME:125%OF DISCHARGED CAPACITY AMGQ_NT IEJOPERATIIRE:29'C(EB'F TO Y2`F) (AN%) AMBIENT TEMPERATURE:20.0 TO 24°C(EBYTO TT`E( 120 100 LL I Q w 60 La' 9 m 40 5 N 100,E US 20 II a9 DOD DOD OFDIISCS AGE 2Q ID 16 D i 2 3 4 5 5.5 LIFE(YEARS) • _._ ,a9 ,xa9 Irb NUMBER OF CYCLER 11F Yuasa Battery Inc. Distributed by 2901 Montrose Ave Laureldale, PA 19605 www.yuasabatteries.com Registered number 1548820 YUASA Cat.No. NP7-12 January 08 P POTTER PVX-150 & PVX-200 The Symbol of Protection Voice Evacuation System Features • Clean Dead-front Construction • Digitally Recorded Automatic Evacuation Message (Up to 20 Minutes of Message Capacity) • 50/100 Watt Bullet-Proof Amplifier ..�-...: • 25 or 70 VRMS Field Selectable • Class A/B Speaker Circuit • 120 VAC Power Supply and Battery Charger • Live Microphone Override of Message and Tone • Analog Addressable Compatible • High Reliability,No Maintenance,Fully Supervised • Easy Installation and Operation • Studio Quality Voice Recordings • Built in Alarm and Alert Signals • • Works with 12 VDC or 24 VDC Fire Alarm Panels • Works with Microprocessor based and Network Fire Alarm Systems • 3 Minute Message Restart on Microphone Key 113 • 24 Hour Backup with 12V 7AH Batteries LISTED • Made in the USA S25376 691 1-0328:0219 Description Technical Specifications The PVX-200/PVX-150 panels provide 200W and 150W of speaker Specifications are given per module: power respectively.Speaker zones can be configured for general alarm or alarm by zone operation as required. Digital message repeater, PVX-50-50 watt module microphone, 120 VAC power supply and battery charger are all built Primary Power 120VAC @0.8A in.The PVX Series voice evacuation can be configured for Churches, 0.15A Standby Restaurants,Movie Theaters,Auditoriums,and High Rise buildings. 24VDC Battery Power .80A Alarm Output 50 Watts 4)25/70 VRMS The paging microphone is an integral component removal of the microphone will cause a` Trouble"condition which will be reporting PVX-100- 100 watt module locally, as well as through the FACP. The PVX-150 / PVX-200 is Primary Power 120VAC @0.8A housed in a surface or semi-flush mounted backbox with a hinged and 0.I6A Standby key locked door. 24VDC Battery Power I.I A Alarm Output 100 Watts @ 25/70 VRMS Backbox Dimensions(WARD) 14.5 x 27 x 4" Color Red(standard)Charcoal Grey (optional) Potter Electric Signal Company,LLC • St. Louis,MO • Tech Support: 866-956-1211 /Customer Service: 866-572-3005 • www.pottersignal.com 8830044-REV B • 12/14 PAGE 1 OF 2 PVX-150 & PVX-200 The Symbol of Protection Voice Evacuation System Typical Installation Fire 0 NAC _l1 II Alarm qy Strobe Circuits Control fQ NAC (Notification Appliance Circuit) IA I EOLR Panel 71�L F R NAC —e— Speaker Circuit EOLR Supervised-Power Limited 120 0II II II EOLR VAC —Il Speaker Circuit EOLR = I Supervised-Power Limited _ 1 CEEEEE E EEEEE-EC Standard Message- 15 Seconds: O (+ O "Attention Please,there has been a report of an emergency. :=o: ■ .:.: o. ■ = Proceed calmly to the nearest exit and leave e the building immediately. Do not use the elevators,use stairwells where necessary. All handicapped occupants shall use the ❑o II�� building evacuation plan." 12V -0 12V -0 12V -0 12V -0 Battery+0 Battery+0 Battery+0 Battery+0 Ordering Information Optional Components Stock • PVX-ZM Zone Module 4-Class B/2-Class A Circuits Model Number Number Description • PVX-SL8 8 Switch/LED Card 150W Voice Evacuation System with: • PVX-IL8 8 Input/LED Card PVX-150/8Z 3500007 Power Supply/Battery Charger • PVX-OL8 8 Output/LED Card • Paging Microphone • PVX-RM/SC Remote MIC/Supervisory Card PVX-150/I2Z 3500008 • Digital Message Repeater • 8 Speaker Zones(8Z) Engineering Specifications PVX-I50/16Z 3500009 • 12 Speaker Zones(12Z) The voice evacuation system shall be Potter PVX 150/200 or approved • 16 Speaker Zones(16Z) equal. The voice evacuation system shall provide 150/200 Watts of signal and voice power,and shall be UL listed.All speaker circuits shall 200W Voice Evacuation System with: be field selectable for 25 or 70 VRMS operation and shall be power PVX-200/8Z 3500010 • Power Supply/Battery Charger limited. The voice evacuation shall be micro-processor based, and • Paging Microphone shall contain an integral microphone, audio amplifer, tone generator Digitaland digital message repeater. A 120 VAC Power Supply and battery PVX-200/l2Z 3500011 Message Repeater charger for standby shall be included.The voice evacuation message/ • 8 Speaker Zones(8Z) signal shall be broadcast until the FACP is reset,or until fire emergency • 12 Speaker Zones(12Z) personnel interrupt the broadcast with a manual page.Remote paging PVX-200/16Z 3500012 microphone(s)will be supported through a supervised circuit. • 16 Speaker Zones(16Z) Potter Electric Signal Company,LLC • St. Louis. MO • Tech Support: 866-956-1211 /Customer Service: 866-572-3005 • www.pottersignal.com ISO aaa1'200S I DESIGNING,MANUFACTURING, CERTIFIED &DISTRIBUTING QUALITY SYSTEMS 8830044-REV 11 • 12/14 PAGE 2 OF 2 P POTTER PVX The Symbol of Protection Voice Evacuation Panels Accessory Cards PVX Accessory Cards • PVX-ZM—Supervised Zone Module • PVX-SL8-1,F.D Switch Card • PVX-IL8—LED Input Card • PVX-OL8—LED Output Card • • All cards connect and communicate over 10 pin ribbon cable :n • Up to 16 total cards per panel in any combination f'< • • •.•s PVX-ZNI PVX-SI.8 PVX-IL8 PVX-OL8 LISTED S25376 PVX-ZM Stock Number: 35I0014 Supervised Zone Module ,— Current draw(24VDC input):5lmA(Standby), 130mA(All Call) ��,� • 4 Class B or 2 Class A speaker circuits(Field selectable) �g • wII • 25/70 Vnns Field selectable ::M. ,• �c f_ • Compatible with PVX-SL8 for zone selection s r U�M M=q�M`tlzos* }.-• M t,V • Circuits rated up to 50W @ 70V and 40W a. 25V I.• .. • Circuits rated up to 50W n 70V and 40W(-t}25V w N The Potter PVX-ZM Supervised Zone Module is used in conjunction ° p57 with the PVX Series Voice Evacuation Panels to provide separately supervised and protected circuits from a single speaker output. The :el y= g d1® EVX-ZM is default configured for 4 Class B circuits, but may be ® ra ® p converted to 2 Class A with the flip of a switch.The PVX-ZM can be ni ganged together to provide a maximum of 64 Class B circuits. ' The PVX-ZM in standard operating mode is strictly All Call. On P3 any page,alarm, or message function all circuits activate. If separate I� ••- "` tw q zoning is required,the PVX-ZM has zone selection inputs which may g,t. be activated by a N.O.dry contact. Additionally,the PVX-SL8(LED fTY Switch Card) may be employed to provide both Zone and Message R pp �©'©" • ®� c,. selection by switch. f� ass� rarea.� '' Each speaker circuit employs smart power metering to insure short circuit conditions are isolated from the other circuits. Each circuit is rated 50W(u�70V and 40W(a 25V. Potter Electric Signal Company,1,LC • St. Louis,MO • Tech Support: 866-956-1211 /Customer Service: 866-572-3005 • www.pottersignal.com 8810072-REV A • 4/15 PAGE 1 OF 2 • P POTTER PVX e The Symbol of Protection Voice Evacuation Panels Accessory Cards PVX-SL8 p Stock Number: 3510015 LED Switch Module Current draw(On primary module battery back-up): 3mA(Standby), . 5.16mA(All Call) on! r., • 8 Momentary switches ONO 14: • 8 Tri-color LED's(green/red/amber) .' 4 • Programmable for multiple functions r a w The Potter PVX-SL8 LED Switch Module provides switch selection PI for message activation,paging,and control functions. ` �w When used in conjunction with the PVX-ZM zone module,the SL8 ' ,• can be programmed for page zone control.LEDs for switches assigned to page zones will indicate Red for page and flashing Red for alarm. lei PIA The LED will indicate Amber if the associated speaker circuit is in a fault condition. Switches can be programmed to control corresponding points on the ' PVX-OL8. Switch LEDs will indicate steady Red on activation. PVX-IL8 ' IL8 m . Stock Number:3510016 LED Input Module Pr Yr Current draw(On primary module battery back-up): 3mA(Standby): 5.2mA(All Call) • . ,�• •ia•�, 1 • '-'. • 8 Input points c G • 8RedLED's ,2 to '� r, * •• • Programmable for multiple functions a . ” a ' tz �„ The Potter PVX-IL8 LED Input Module can be used for page zone a •1 "li4 .I6yi G �. control, message selection, and control functions. The inputs • C' monitor an external N.O dry contact. PVX-lL8's are typically used Ea :: :: i G for message/zone activation from an outside system such as Severe Weather Warnings. They can also be used to activate corresponding D • 0 outputs on the PVX-OL8. On activation,the corresponding LED will II 0 NO 0 ■ indicate red. 0 mA, g1S 0 PVX-OL8 Stock Number: 3510017 . ' , m• LED Output Module .: • .µ - T-wa "`-. Current draw(On primarymodule batteryback-up): 3mA(Standby), atit 28mA(All Call) • 8 Input points "1 i ! no3 EA a P ��1 • • 8 Red LED's a" • • N.O.Dry contacts rated at 30mA'r)0-24VDC +• • : ' ."'^"'d` •,, •, • The PVX-OL8 LED Output Module provides solid state N.O. dry '� t 'I •• :rtmtr"„` I 1 • contacts. It can also be separately tied to a voltage(0-24VDC).with "se yf "' 4 that voltage used as a drive point or trigger. Outputs t and 5-8 may ,,.. •••• 11,t use different voltage references if desired. The PVX-OL8 outputs may A, • °ewac,w w be programmed to follow message activation,page zones.or specific functions like PTT,alarm,or control. Potter Electric Signal Company,LLC • St. Louis, MO • Tech Support: 866-956-1211 /Customer Service: 866-572-3005 • www.pottersignal.com Ism soo•:zoos I DESIGNING,MANUFACTURING, CERTIFIED I&DISTRIBUTING QUALITY SYSTEMS 8830072-REV A • 4/15 PAGE 2 OF 2 NP SERIES - NP 12 -12 1 Data Sheet Reliability is your Security Utilizing the latest advance design Oxygen _ Recombination Technology, Yuasa have applied their 80 years experience in the lead acid battery Nv x '`= field to produce the optimum design of Sealed ,,, Lead Acid batteries. .r roasA ,-- . ; FEATURES ". � • Superb recovery from deep discharge. • Electrolyte suspension system. :"e• • Gas Recombination. • Multipurpose: Float or Cyclic use. • Usable in any orientation. Terminals • Superior energy density. NP batteries are manufactured using a range of terminals which • Lead calcium grids for extended life. vary in size and type. Please refer to details as shown. • Manufactured World wide. an Operation in Orientation • Application specific designs. p Y The combination of sealed construction and Yuasa's unique Technical Features electrolyte suspension system allows operation in any orientation,with no loss of performance or fear of electrolyte Sealed Construction leakage. Yuasa's unique construction and sealing technique ensures no electrolyte leakage from case or terminals. Valve Regulated Design The batteries are equipped with a simple, safe, low pressure Electrolyte Suspension System venting system which releases excess gas and automatically All NP batteries utilize Yuasa's unique electrolyte suspension reseals should there be a build up of gas within the battery due system incorporating a microfine glass mat to retain the to severe overcharge. Note. On no account should the battery be maximum amount of electrolyte in the cells.The electrolyte is charged in a sealed container. retained in the separator material and there is no free General electrolyte to escape from the cells. No gels or other contaminants are added. Specifications`. Control of Gas Generation Nominal Capacity (Ah) NP12-12 The design of Yuasa's NP batteries incorporates the very latest oxygen recombination technology to effectively control the 20hr to 1.75vpc 30°C 12 generation of gas during normal use. 10hr to 1.75vpc 20°C 11.1 Low Maintenance Operation 5hr to 1 .70vpc 20°C 10 Due to the perfectly sealed construction and the 1 hrto 1 .60vpc20°C 7.2 recombination of gasses within the cell,the battery is almost Voltage 12 maintenance free. Energy Density(wh L 20hr) 1 04 Terminals Layout Specific Energy(wh.kgzohr) 36 Int.Resistance(m.Ohms) 1 6 Faston tab: 250 D 4 � Maximum discharge(A) 75 2�,nw Short Circuit current(A) 360 —1 I4— INCH=MM Dimensions (mm) .310 7.90Q Length 151 .250 6.3535 �/ Width 98 I n .16 4.0 —O .031 0.8 Height overall 97,5 .020 0.5 Weight(Kg) 4.05 --+ +-- Terminal D "a'=.oa Layout 4 Terminal Torque Nm - www.yuasabatteries.com Data Sheet NPSERIES - NP 1 2 -1 2 le Lead Calcium Grids Long shelf Life The heavy duty lead calcium alloy grids provide an extra margin The extremely low self discharge rate allows the battery to be of performance and life in both cyclic and float applications and stored for extended periods up to one year at normal ambient give unparalleled recovery from deep discharge. temperatures with no permanent loss of capacity. Long Cycle Service Life Operating Temperature Range Depending upon the average depth of discharge,over a The batteries can be used over a broad temperature range thousand discharge/charge cycles can be expected. permitting considerable flexibility in system design and location. Float Service Life Charge —15°C to 50°C The expected service life is five years in float standby Discharge—20°C to 60°C applications. Storage —20°C to 50°C (fully charged battery) Separators The use of the special separator material provides a very efficient SELF DISCHARGE CHARACTERISTICS insulation between plates preventing inter-plate short circuits 0.)1,5 _ 1 and prohibiting the shedding of active materials. CYCLIC RECHARGE REGIME L " 1CLC 150•F) Bak Chaos A s�wWCnvoe S 0.9 1m A ,] la so - .---204c 9194) A Rao.1 y Ilene.V0 OAS - 125 —19 `�1 +ar It6aY7 .n•e MVP) T9I CluBA Vdnn9 25 _ — OA -L100— —t5 u Chu9♦ Mge —14 1 It 435 -1 W ]5— = 0 B 9 12 15 19 —13 1. STORAGE TIME IV0i,IHS) u 0.1 -g so- CuneM Trm PPP �13 am`A FLOAT CHARGE CHARACTERISTICS _„ CtotMo Current R 0 0 'r. 10 or2s(( u5u�ug�i4g�§§3 V: 03 a'+ A V>4a 025CA-2.275VPC CONSTANT VOLTAGE CHARGING Y NP DISCHARGE CHARACTERISTICS 1%) UC✓0 (V1 AT20.COWE) CURVES AT 259C (779F) 140 M PG M Nde:C.ON♦n 120 0]b FOR 12V FOROV cepY+lT e9 W:BOM NN GOenf BEM ]59 � RpEp VOl11ME__ ISA BATTERY BATTERY ___- 13.6 5.5HP AT 254C I]1'L) 100 O.20 �_ ]m' CHARGE VOLTAGE 14.0 p o15 tx0- 9.0 /J/J �^.� '`\\\� 40 0b°/� I AFTER IQy.°pCHARGE[:: : \\ a.,oAIR So%ds5HAR0E \\`* w CD, tza -o rr aac..03 wr+ 2,,, OAS 55o r 11.0 LHAROWO CURRENT 0 A A 0- 5 ,'q. 0 0 2 ♦ - 0 8 10 12 14 15 le 20 C11AR60I0715E(HOM) 5.0- AA ,5A TYPICAL DISCHARGE CHARAC- 2 015 2, PO 2 5 91a To TERISTICS NP RANGE MMITE6 DISCHARGE TIME HOURS CYCLE SERVICE LIFE IN RELATION FLOAT SERVICE LIFE NP RANGE TO DEPTH OF DISCHARGE TESTMG COMMONS.DISCHARGE CURRENT:G G1 CURRENT .0ee Amp. CHARGING CURRENT.CAP CITY y CAMOWO TEMPERATURE OF M DISCHARGED TO TM • [AH'a) tE6114�CfM1ryNT TEMPCGA-URr TCGE $2TSVP0 a 1u10r) AMBENT TEMPERATURE:20Y:TO YSC(WE TO TM U AVGIrAT TCMPCIATUriC.OTC f5G4T0]T'T) lap Q no 2 _ S 'q47 ^'ems_ a lob/ ,� b m J o d0 U L` 6F °O 100* Ea 3rA0EPrH w 1 a OOD 000 of Gmr•�.acE _,C se a20ee ti 4 o 9) 2 3 4 5 5.5 IMP ace epo we IMP 1200 1440 I IFF(YEARS) NUMBER OF CYCLES 117 Yuasa Battery Inc. Distributed by 2901 Montrose Ave Laureldale, PA 19605 www.yuasabatteries.com Registered number 1548820 YUASA Cat.No. NP 12-12 March 09 I P POTTER S-24 & HS-24 SELECTABLE CANDELA The Symbol of Protection STROBE &HORN/STROBES Features • 24VDC units have field selectable candela options of 15,30,60, 75,& 110 • Super-Slide®Bracket-Ease of Supervision Testing • Checkmate®-Instant Voltage Verification • Synchronize strobe and/or horn with AVSM Control Module • Prewire entire system,install mounting bracket,then install �. �-"---- -' signals • Documented lower installation and operating costs fill I� • Input terminals accept 12 to 18 AWG wFa I :It ' dl, Switch selection for high or low dBA • Switch for chime,whoop,mechanical and 2400Hz tone R p i • Tamperproof re-entrant style grill l 1111 III Switch for continuous or temporal 3 tone(not available on whoop tone) • Surface mount with the AVBB(Surface Mount Back Box) • Silence audible while visual appliance will remain flashing(for use in accepted jurisdictions) • Faceplate available in red or off-white Operating Temperature • 32°F to 120°F(0°C to 49°C).The HS and S Series are not listed for outdoor use. Unit Dimensions • 5"(12.7 cm)high x 4.5-(11.43 cm)wide x 2.5"(6.35 cm)deep (1211 LISTED S3247 Description The S-24/HS-24 Series is a low profile strobe and horn/strohe This Series is shipped with a standard 4" metal mounting combination that offers dependable audible and visual alarms and the plate which incorporates the popular Super-Slide®feature that allows absolute lowest current available. the installer to easily test for supervision. The product also features a locking mechanism which secures the product to the bracket without The S-24 & HS-24 Series 24VDC offers tamperproof field any screws showing. selectable candela options of 15,30,60,75,and 110 candela. The S-24/HS-24 also features the patented Checkmate® - The Strobe and Horn/Strobe offers a continuous or sync Instant Voltage Verification feature which allows the installer to check temporal three in 2400Hz and mechanical tone, a chime and whoop the voltage drop draw and match it to the blueprint. tone.All tones are easy for the professional to change in the field by the use of switches. The S-24& HS-24 Series appliances are ANSI/UL 464 and ANSI/UL 1971, listed for use with fire protective systems and are The S-24 & HS-24 Series has a minimal operating current warranted for three years from date of purchase. and has a minimum flash rate of 1Hz regardless of input voltage. PotterElectric Signal Company,LLC•St.Louis,M063042 USA•CustSery ice.866-572-3005*Tech Support:866-956-0988•Canada888-882-1833•www.pottersignal corn PRINTED IN USA MFG.#8830054-REV A PAGE I OF 4 06/13 P POTTER S-24 & HS-24 SELECTABLE CANDELA The Symbol of Protection STROBE & HORN/STROBES Tone Switch Locations TONE SWITCH POSITION ■ 3 4 5 it-. •M i Mechanical Temporal 3 ON ON ON �[N• ..zip 1\ Mechanical-Continuous OFF ON ON 2400Hz-Temporal 3 ON OFF ON �wM MN $+ t 2400Hz-Continuous OFF OFF ON �pU •u �i �i =` Chime-Temporal 3 ON ON OFF I I. p HI. �i Chime-Continuous OFF ON OFF ciml ■ II p H• t ii-. Whoop ON OFF OFF CY Whoop OFF OFF OFF NOTE: • Switch Positions 1 and 2 in the OFF position to select isolated horn and strobe power inputs • Switch Position 6 ON=HIGH dBA • Switch Position 6 OFF=LOW dBA Super Slide Mounting Bracket I Checkmate*Instant Allows the installer to pre-wire , Voltage Verification the system,test for system II\ t It is often necessary to confirm the voltage supervision,remove the signal Si jill , drop along a line of devices.The access head until occupancy, ` holes are provided in the back of the p cy,switch out signals without \1111 - — r. terminal block to allow the voltage to be changing mounting brackets l I to� measured directly without removing the and has locking edge connector -'l, ii device.Typically,this would be done at the for snap-in-place installation. _�` end of line to confinn design criteria.Most ";04-1111ft II measurements will be taken using the S+ • and S-locations althouhg access is provided to other locations. NOTE:Care should he taken to not short the test probes. Candela selection slider switch. Depress center and slide switch to desire brightness level. _ N? 0 Break off pin and insert I IR into hole at the bottom of1: !� s the selector to lock �. candela setting.Signal ����� ���)must be removed fromIli bracket and pin pushed �r P' 1 1 �1[.'forward from backside out ''t��lJiii1i �+�j-!__�/ of hole to change candela. l `— To remove bezel,grip both sides of bezel and pull in a download and outward motion. PotterElectric Signal Company,l..LC•St.Louis,MO 63042 USA•Cust Service:866-572-3005*Tech Support:866-956-0988•Canada 888-882-1833•wwwpottersignal.corn PRINTED IN USA MFG 68830054-REV A PAGE 2 OF 4 06/13 I P POTTER S-24 & HS-24 SELECTABLE CANDELA The Symbol of Protection STROBE & HORN/STROBES S-24 24 VDC Selectable Candela,Low Profile Evacuation Strobe Model Part Nominal Candela Number Number Voltage (ANSI/UL 1971) S-24WR 4890010 24 VDC 15,30,60,75, 110 S-24WW 4890011 24 VDC 15,30,60,75, 110 HS-24 24 VDC Selectable Candela,Low Profile Evacuation Horn/Strobe Model Part Nominal Candela Reverberant dRA at In Anechoic Room Number Number Voltage (ANSI/UL 1971) 10 ft.,perANSl/UL464 dBA at 10 ft. HS-24WR 4890030 24 VDC 15,30,60,75,110 62-82 100 HS-24WW 4890031 24 VDC 15,30,60,75, 110 62-82 _ 100 S-24&HS-24 Product Strobe Current Ratings(mA) 24 VDC(16-33 Volts) Model Designations: N'=Wall Mount Candela 24 VDC UL Maxi R=Red Faceplate W=White Faceplate 15 cd 30 mA 42 mA 30 cd 35 mA 58 mA All units are available in plain(no lettering). Plain units are non-returnable. 60 cd 66 mA 97 mA 75 cd 80 mA 116 mA ALERT bezel available for order. 110 cd 103 mA 161 mA ALERT bezel available for order. S-24&HS-24 Product Horn Current Ratings Horn Decibel Levels Horn Current Ratings Minimum SPL Minimum SPL Regulated 24 VDC horn Mode at 10 ft.,per at 10 ft,per Max.Operating(If(), ANSUUL 464 ANSI/UL 464 High Setting(mA) (HIGH) (LOW) Temp 3 2400 Hz 78 dBA 71* dBA 28 mA Temp 3 Mechanical 76 dBA 70*dBA 25 mA Temp 3 Chime 70*dBA 66* dBA 15 mA Continuous 2400 Hz 81 dBA 74*dBA 28 mA Continuous Mechanical 80 dBA 72*dBA 25 mA Continuous Chime 70*dBA 66*dBA 15 mA Whoop 82 dBA 69*dBA 56 mA NOTES: • For nominal and peak current across ANSI/UL regulated voltage range for filtered DC power and unfiltered(FWR)Full Wave Rectified]) power,see installation manual. • Potter does nto recommend usign a coded or pulsing signaling circuit with any of our strobe products. • The sound output for the temporal 3 tone is rated lower since the time the horn is off is averaged into the sound output rating.While the horn is producing a tone in the temporal 3 mode its sound pressure is the same as the continuous mode. * Operating the horn in this mode at this voltage will result in not meeting the minimum ANSI/UL 464 reverberant sound level required for public mode fire protection service.These settings are acceptable only for private mode fire alarm use.Use the high dBA setting for public mode application(not applicable when using the chime tone.The chime tone is always private mode). PotterElectric Signal Company,LLC•St,Louis,MO 63042 USA•CustService:866-572-3005•Tech Support:866-956-0988•Canada 888-882-1833•www.pottersignal.com PRINTED IN USA MFG.68830054-REV A PAGE 3 OF 4 06/13 P POTTER S-24 & HS-24 SELECTABLE CANDELA The Symbol of Protection STROBE & HORN/STROBES Architect&Engineering Specifications The audible and/or visible signal shall be Potter S-24 strobe and Potter HS-24 horn/strobe Series or approved equal and shall be listed by Underwriters Laboratories,Inc.perANSI/UL 1971 and/or ANSI/UL 464.The notification appliance shall also be listed with Factory Mutual Listing Service(FM)and the California State Fire Marshal(CSFM). The notification appliance(combination audible/visible)shall produce a peak sound output of lOOdBA or greater at 24VDC as measured in an anechoic chamber.The signaling appliance shall also have the capability to silence the audible signal while leaving the visible signal energized with the use of a single pair of power wires.Additionally,the user shall be able to select either continuous or temporal tone output with the temporal signal having the ability to be synchronized. Unit shall be capable of being installed so that any unauthorized attempt to change the candela setting will result in a trouble signal at the fire alarm control panel. The audible/visible and visible signaling appliance shall also maintain a minimum flash rate of IHz or up to 2Hz regardless of power input voltage.The strobe appliance shall have an operating current of 42mA or less at 24VDC for the I 5Cd strobe circuit. The appliance shall he polarized to allow for electrical supervision of the system wiring.The unit shall be provided with a mounting bracket with terminals and barriers for input/output wiring and he able to mount to a single gang or double gang box or double workbox without the use of an adapter plate.The unit shall have an input voltage range of 16-33 volts with either direct current or full wave rectified power for 24VDC models. The appliance shall be capable of testing supervision without disconnecting wires,verify voltage without removing unit and be capable of mounting to a surface back box. Conventional Wiring Diagrams for Emergency Notification Evacuation Series UL Listed UL Listed Control Signal signal Control Panel Panel Signal Sip,el S+ S+ S- H+ H- S+ S+ S- H+ H- S+ 8+ S- H+ H- S+ S+ S- H+ H- Supervised ► . I . .Y Supervised 9 6 S B B 9 6 S 0 0 Signal Circuit 6111=111g ' " END OF LIRf Signal Circuit ENO RESIST PE RESISTOR O 1' 11 Q 1111 RESISTOR END OF LINE NOTES: • All strobes are designed to flash as specified with continuous applied voltage. Strobes should not be used on coded or pulsing signaling circuits.However,use of the Potter AVSM control module or Gentex synchronization protocol is permitted to synchronize the strobe,horn,and/or mute the horn. • FOR SYNCHRONIZATION WIRING INFORMATION,REFERENCE AVSM CONTROL MODULE DATA SHEET(8830050) AND/OR AVSM CONTROL MODULE MANUAL FOR SYNCHRONIZATION MODULE WIRING DIAGRAMS.AVSM CONTROL MODULE DATA SHEET AND MANUAL CAN BE OBTAINED AT http://pottersignal.com OR CALL POTTER ELECTRIC AT 1-800-325-3936. Potter ElectricSignal Company,LLC•St Louis,MO 63042 USA.CustSery ice:866-572-3005.Tech Support:866-956-0988-Canada888-882-1833•www pottersignal.com PRINTED IN USA MFG.#8830054-REV A PAGE 4 OF 4 06r 13 -tI FASPKRASPKSTR-24CLP P POTTER Indoor Low Profile Speaker and Ceiling The Symbol of Protection Speaker/Strobe Series Features • 24VDC tamperproof selectable candela options of 15,30,60,75,and 110 • Speaker voltage 25 or 70.7 VRMs standard,field selectable • Field selectable power taps: 1/8W, 1/4W. I/2W, 1 W,2W,4W • High quality dlA output(intelligible) II r • Frequency range 400-4000 Hz • Screw Terminals,separate in/out wiring(18-12 gauge) • Tampelproofgrill • Faceplate available in red or off-white • Product includes a 5 year warranty S '��.. •�+.r 11111 W1111111 LISTED S2657 7320-0328:0208 Application Product Listings The Potter SPKSTR-24CLP is a ceiling mount,low profile,field • ANSI/UL 1480,ANSI/UL1971 and ANSI/UL 2043 adjustable speaker/strobe and the FASPKR is a universal mount • CSFM 7320-0328:0208 speaker designed to meet code requirements for audio,visual,and voice communications.The SPKSTR-24CLP Series are quality speaker products offering dependable evacuation signaling,visual alarms,or a combination of both. Product Compliance • Americans with Disabilities Act(ADA) Description • NFPA 72 The SPKSTR-24CLP has high output tamperproof candela selections • IBC/IFC/IRC of 15,30,75.95,and 115.The SPKSTR-24CLP and FASPKR provide a 25 or 70.7 VRMs speaker with field selectable power taps of 1/8W, 1/4W, 1/2W, 1W,2W,or 4W.The SPKSTR-24CLP strobes can be Technical Specifications synchronized using the PotterAVSM Synchronization Control Module, Speaker Operating Voltage 25VRMs or 70.7VRMs FACP,or power supplies that produce a Gentex Synchronization Protocol. Strobe Operating Voltage 16-33VDC Synchronization Module Potter AVSM The SPKSTR-24CLP and FASPKR can be mounted to a 4"X 2 1/8" 32°F to 120°F deep back box without an extension ring or Potter SPKRBB surface Environmental Limitations Indoor Only back box. Unit Dimensions 6.1"(15.494cm)square The SPKSTR-24CLP and FASPKR are constructed of high textured X 1.88"(4.7752cm)deep plastic. Back Box 4"X 2 1/8"deep box or Potter SPKRBR surface back box Shipping Weight 1.5 lbs. Potter Electric Signal Company,LLC • St. Louis,MO • Tech Support: 866-956-1211 /Customer Service: 866-572-3005 • www.pottersignal.com 10190060-REV B • 10/14 PAGE 1 OF 3 r P POTTER FASPKR/SPKSTR-24CLP O Indoor Low Profile Speaker pa er and Ceiling The Symbol of Protection Speaker/Strobe Series SPKSTR-24CLP Product Strobe Current Ratings Low Profile Evacuation Speakers Candela 15 cd 30 cd 75 cd 95 cd 115 cd Model Number Description Stock Number 24 VDC 72 mA 101 mA 167 mA 200 mA 214 mA FASPKR-R Speaker Red 4890200 UL Max 120 mA 120 mA 200 mA 220 mA 290 mA FASPKR-W Speaker White 4890201 Speaker dBA @ 10 ft. Low Profile Evacuation Speakers Input Watts 25 Volts 70.7 Volts Model Number Description Stock Number 1/8 74.6 dBA 73.7 dBA SPKSTR-24CLPR Speaker/Strobe Red 4890220 1/4 77.7 dBA 76.7 dBA SPKSTR-24CLPW Speaker/Strobe White 4890221 1/2 80.5 dBA 79.6 dBA SPKSTR-24CLPPR Speaker/Strobe Plain Red 4890222 I 83.1 dBA 82.5 dBA SPKSTR-24CLPPW Speaker/Strobe Plain White 4890223 2 85.6 dBA 85.4 dBA 4 87.9dBA 87.9dBA Model Designations NOTE: P=Plain(No Lettering) • Potter does not recommend using a coded or pulsing signaling W=Ott=White Faceplate Ile circuit with any of our strobe products. R=Red Faceplate Plain units are non-returnable Architect and Engineering Specifications The fire alarm speaker shall be Potter FASPKR.SPKSf R-24CLP or equivalent.The speaker shall be capable of producing alarm tones or voice on all 25 or 70.7 VRMs audio systems.The speaker shall provide incremental tap settings of 1/8,1/4, 1/2, 1,2,or 4 watts.Minimum dBA ratings at 1/4 watt shall be 76.7 dBA and at 4 watts 87.9dBA.Tap settings shall he adjustable with field selectable jumper pins.The speaker shall also have an optional visual signal capability. The visual signal shall have a 1 Hz flash rate regardless of input voltage.All field wiring connections shall be made via separate in-out terminal connections and the speaker or speaker strobe shall be ANST/UL,CSFM listed and comply with all local,state and federal fire alarm codes/standards. Potter Electric Signal Company,LLC • St. Louis, MO • Tech Support: 866-956-1211 /Customer Service: 866-572-3005 • www.pottersignal.com 8830060-REV R • 10114 PAGE 2 OF 3 P P OTT'u\ FASPKRISPKSTR-24CLP Indoor Low Profile Speaker and Ceiling The Symbol of Protection Speaker/Strobe Series SPKSTR-24CLP Candela Power Tap Selection Mounting Diagram Selection • LINE . VOLTS — /�� _ ®®® `N %_ =;� °00��11100���11r� goo "�® ems 1 ii tea Adjust �� ��_.o (----- �� �E.R�� �_ Power taps ®.lu•,q 1, vz P ^� using needle I .r_�, Jue t g �I bl F*?�®�-�c, i Iq me 2 nose pliers. I��� d iirz a IlkII V \\..........„____ 1 VP Mounts to a standard 4"square X 2 1/8" Adjust candela setting by turning dial back box or Potter SPKRBB surface back with screwdriver.Candela selection is box. displayed on front of unit. Wiring Diagram TO NOR APPLIANCE FROM UST APPLIANCE SPEAKER + 0 NOTE:DO NOT USE 25 OR 70V EOLR SOURCE - 0 111 LOOPED WIRE TINDER TERMINALS. BREAK WIRE STROBE TONarAPPLWI(f FROM LASTAPPLCE RUNT()PROVIDE 24V POWER + 0- III / Ng 4 EOLR SUPERVISION OF SOURCE II III 44 CONNECTION. La EC ] WIRE CONDUCTIVITY MOSE (OPTB]NAL) SPEAKER 18 AWG 60 16AWG 95 14AWG 153 12AWG 244 • MAX WIRE DISTANCE- PANEL VOLTAGE-DEVICE MINIMUM VOLTAGE X WIRE CONDUCTIVITY TOTAL CURRENT DRAW • CAUTION: APPLIES ONLY TO REGULATED SUPPLIES. • NOTICE: POWER IS SUPPLIED TO DEVICES WHEN CONTROL PANEL IS LATCHED. Potter Electric Signal Company,LLC • St. Louis, MO • Tech Support: 866-956-1211 /Customer Service: 866-572-3005 • www.pottersignal.com ISO BOOT 2ooa I DESIGNING,MANUFACTURING, CERTIFIED &DISTRIBUTING QUALITY SYSTEMS 8830060-REV B • 10/14 PAGE 3 OF 3 PPOTTER PO 1 1 ER Indoor Low Profile Wall Mount The Symbol of Protection Speaker/Strobe Series Features • 24VDC tamperproof selectable candela options of 15,30,60.75,and 110 • Speaker voltage 25 or 70.7 VRMs standard,field selectable • Field selectable power taps: 1/8W, I/4W, I/2W, 1 W,2W,4W • Xenon strobe maintains constant flash rate(I Hz) /, • • High quality dBA output(intelligible) • Frequency range 400-4000 Hz 4 �f . �.. � • Screw'terminals,separate in/out wiring(18-12 gauge) • Tamperproof grill • • Faceplate available in red or off-white • • Product includes a 5 year warranty I I` IIIIIIIII1II� LISTED S2657 7320-0328:0207 Application Product Listings The Potter SPKSTR-24WLP is a wall mount,low profile,field • ANSI/UL 1638,ANSI/UL197I and ANSI/UL 1480 adjustable speaker/strobe designed to meet code requirements for • CSFM 7320-0328:0207 audio,visual,and voice communications.The SPKSTR-24WLP Series are quality speaker products offering dependable evacuation signaling, visual alarms,or a combination of both. Product Compliance Description • Americans with Disabilities Act(ADA) • NFPA 72 The SPKSTR-24WLP has high output tamperproof candela selections of 15,30,75,95,and 115.The SPKSTR-24WLP provides a 25 or 70.7 • IBC/IFC/IRC VRMs speaker with field selectable power taps of I/8W, I/4W, I/2W, 1 W,2W,or 4W.The SPKSTR-24WLP strobes can be synchronized using the PotterAVSM Synchronization Control Module,FACP,or Technical Specifications power supplies that produce a Gentex Synchronization Protocol. Speaker Operating Voltage 25VRMs or 70.7VRMs The SPKSTR-24WLP can be mounted to a 4"X 2 1/8"deep back box Strobe Operating Voltage 16-33VDC without an extension ring or Potter SPKRBB surface back box. Synchronization Module Potter AVSM The SPKSTR-24WLP is constructed of high textured plastic. Environmental Limitations 32°F to Only n Indoor O Only Unit Dimensions 6.1"(15.494cm)square X 1.88"(4.7752cm)deep Back Box 4"X 2 1/8"deep box or Potter SPKRBB surface back box Shipping Weight 1.5 lbs. Potter Electric Signal Company,LLC • St. Louis,MO • Tech Support: 866-956-1211 /Customer Service: 866-572-3005 • www.pottersignal.com 8830061-REV B • 10/14 PAGE 1 OF 3 SPKSTR-24WLP� P POTTER Indoor Low Profile Wall Mount The Symbol of Protection Speaker/Strobe Serzes SPKSTR-24CLP Product Strobe Current Ratingsjr. Low Profile Evacuation Speakers Candela 15 cd 30 cd 60 cd 75 ed 110 cd Model Number Description Stock Number 24 VDC 55 mA 63 mA 88 mA 112 mA 136 mA SPKSTR-24WLPR Speaker/Strobe Red 4890210 UL Max 78 mA 96 mA 137 mA 180 mA 224 mA SPKSTR-24WLPW Speaker/Strobe White 4890211 SPKSTR-24WLPPR Speaker/Strobe Plain Red 4890212 Speaker dRA C.10 ft. SPKSTR-24WLPPW Speaker/Strobe Plain White 4890213 Input Watts 25 Volts 70.7 Volts 1/8 74.6 dBA 73.7 dBA 1%4 77.7 dRA 76.7 dBA Model Designations 1/2 80.5 dBA 79.6 dBA P=Plain(No Lettering) 1 83.1 dBA 82.5 dRA W=Off-White Faceplate 2 85.6 dBA 85.4 dBA R=Red Faceplate 4 87.9 dBA 87.9 dBA NOTE: Plain units are non-returnable • Potter does not recommend using a coded or pulsing signaling circuit with any of our strobe products. Architect and Engineering Specifications The fire alarm speaker shall be Potter SPKSTR-24WLP or equivalent.The speaker shall be capable of producing alarm tones or voice on all 25 or 70.7 VRMs audio systems.The speaker shall provide incremental tap settings of 1/8,1/4,1/2, 1,2,or 4 watts.Minimum dBA ratings at 1/4 watt shall be 76.7 dBA and at 4 watts 87.9dBA.Tap settings shall be adjustable with field selectable jumper pins.The speaker shall also have an optional visual signal capability. The visual signal shall have a 1 Hz flash rate regardless of input voltage.All field wiring connections shall be made via separate in-out terminal connections and the speaker or speaker strobe shall be ANSI/UL,CSFM listed and comply with all local,state and federal fire alarm codes/standards. Potter Electric Signal Company,LLC • St. Louis, MO • Tech Support: 866-956-1211 /Customer Service: 866-572-3005 • www.pottersignal.com 8830061-REV B • 10,14 PAGF.2 OF 3 • lb SPKSTR-24WLP� P POTTER Indoor Low Profile Wall Mount The Symbol of Protection Speaker/Strobe Series SPKSTR-24WLP Power Tap Selection Mounting Diagram Candela Selection , LINE VOLTS '_ •' ®® y14 /•t.- , Aa ����IIOII �I���IOo u • 1 ,/a Adjust = i,o � E+r+l 112 Power taps � I.•► �1fB using needle _ %p , $1 l ®'• ` Ip we./ s nose pliers. `/ �1 $ IiliminII d Mtn a " !, o . �11 +3 — j&�1��/ ;Q-s' l tr tl I Mounts to a standard 4"square X 2 1/8" Adjust candela setting by turning dial back box or Potter SPKRBR surface back with screwdriver.Candela selection is box. displayed on front of unit. Wiring Diagram TO NIXT APPLIANCE/I FROM LAST APPLIANCE SPEAKER + 0 NOTE:DO NOT USE 25 OR 70V EOLR SOURCE - 0 l -LOOPED WIRN, UNDER TERMINALS. BREAK WIRE STROBE NEXT "'" " FROM ��P11'N8E RUN TO PROVIDE 24V POWER + 0 III EOLR St'PERVISION OF SOURCE �I I !! r CONNECTION. [IZig [I][ ] WIRE CONDUCTIVITY oPTOBE SPEAKER 18 AWG 60 16AWG 95 14AWG 153 12AWG 244 • MAX WIRE DISTANCE- PANEL VOLTAGE-DEVICE MINIMUM VOLTAGE X WIRE CONDUCTIVITY TOTAL.CURRENT DRAW • CAUTION:APPLIES ONLY TO REGULATED SUPPLIES. • NOTICE: POWER IS SUPPLIED TO DEVICES WHEN CONTROL PANEL IS LATCHED. Potter Electric Signal Company,LLC • St. Louis, MO • Tech Support; 866-956-1211 /Customer Service: 866-572-3005 • www.pottersignal.com ma soot:200E I DESIGNING,MANUFACTURING, CERTIFIED I S DISTRIBUTING GUALITYSYSTEMS 8830061-REV B • 10/14 PAGE 3 OF 3 • �I WSSPK P POTTER Outdoor Wall Mount Speaker and The Symbol of Protection Speaker Strobe Series Features • 24VDC fixed 15/75 candela • WSSPK series shipped with Gentex GBLP outdoor back box • Field selectable power taps: 1/8W, 1/4W. 1/2W, 1W,2W.4W • High qualitydBA output(intelligible) =u ��- • Frequency range 400-4000 Hz �• m • Screw terminals,separate in/out wiring(18-12 gauge) • Tamperproof grill • Speaker voltage 25 or 70.7 VRMS standard,field selectable • Faceplate available in red or off-white • Strobe synchronization with Potter AVSM module • Product includes a 5 year warranty 1011) LISTED Application Product Listings The Gentex WSSPK series is an outdoor listed, wall mount, field • ANSI/UL 1480,ANSI/Ut.1638 Listed adjustable speaker and speaker/strobe designed to meet code • CSFM 7320-0569:0141 requirements for audio, visual, and voice communications. The WSSPK Series are quality speaker products offering dependable evacuation signaling, visual alarms, or a combination of both. The Product Compliance WSSPK24-15/75 speaker/strobe offers a fixed 15/75 candela strobe. • Americans with Disabilities Act(ADA) Description • NFPA72 The WSSPK Series provides a 25 or 70.7 VRMS speaker with field • IBC/IFC/IRC selectable power taps of I/8W, I/4W, I/2W, 1W, 2W, or 4W. The WSSPK24-15/75 provides a fixed 15/75 candela strobe output. The strobe can be synchronized using the Potter AVSM Synchronization Technical Specifications Control Module, FACP, or power supplies that produce a Gentex Speaker Operating Voltage 25VRMs or 70.7VRMs Synchronization Protocol. Strobe Operating Voltage 16-33VDC The WSSPK Series grills are constructed of high impact textured Synchronization Module Potter AVSM plastic.Included with the WSSPK Series speaker and speaker/strobe is the GBLP outdoor listed back box.Using the GBLP back box with the Environmental Limitations -31°F to 150°F WSSPK Series provides protection from weather related conditions and allows the necessary full candela output. WSSPK-6.1"square X 3.19"deep Unit Dimensions WSSPK24-6.1"square X 4.0625" deep Back Box Includes GBLP outdoor back box Potter Electric Signal Company,LLC • St. Louis,MO • Tech Support: 866-956-1211 /Customer Service: 866-572-3005 • www.pottersignal.com 8830062-REV B • 08115 PAGE 1 OF 3 WSSPK Pj) POTTER Outdoor Wall Mount Speaker and The Symbol of Protection Speaker Strobe Series WSSPK24-15/75 Strobe Current Rating Outdoor Evacuation Speakers(Speaker Only) Candela 15/75 cd Model Number Description Stock Number 24 VDC 63 mA WSSPKR Speaker Red 4890204 UL Max 96 mA WSSPKW Speaker White 4890205 Speaker dBA!u. 10 It. Outdoor Evacuation Speaker/Strobes Fixed 15/75 candela Input Watts 25 Volts 70.7 Volts 1 Model Number Description Stock Number 1/8 74.6 dBA 73.7 dBA WSSPK24-15/75WR Speaker/Strobe Red 4890206 1/4 77.7 dBA 76.7 dBA WSSPK24-15/75WW Speaker/Strobe White 4890207 1/2 80.5 dBA 79.6 dBA 83.1 dBA 82.5 dBA Model Designations 2 85.6 dBA 85.4 dBA W=Off-White Faceplate 4 87.9 dBA 87.9 dBA R=Red Faceplate NOTE:Potter does not recommend using a coded or pulsing signaling circuit with any of our strobe products. Architect and Engineering Specifications The fire alarm speaker shall be Gentex WSSPK,WSSPK24-15/75 or equivalent.The speaker shall be capable of producing alarm tones or voice on all 25 or 70.7 VRMs audio systems.The speaker shall provide incremental tap settings of 1/8, 1/4, 1/2,I,2,or 4 watts.Minimum dBA ratings at 1/4 watt shall be 76.7 dBA and at 4 watts 87.9dBA.Tap settings shall be adjustable with field selectable jumper pins.The speaker shall also have an optional visual signal capability. The visual signal shall have a 1 Hz flash rate regardless of input voltage.All field wiring connections shall be made via separate in-out terminal connections. The appliance has extended termperature range of-31°to 150°F(-35°to 66°C).The appliance shall satisfy all outdoor and severe environment applications. The GBLP back box includes a gasket that must be inserted between the box and device.There are drain holes in the back box to allow for draingage,the seal on the GBLP is not water tight.The speaker or speaker/strobe shall be ANSI/UL,CSFM listed and comply with all local,state and federal fire alarm codes/standards. Potter Electric Signal Company,LLC • St. Louis, MO • Tech Support: 866-956-121 1 /Customer Service: 866-572-3005 • www.pottersignal.com 8830062-REV B • 08115 PAGE 2 OF 3