Loading...
Permit ipl v CITY OF TIGARD MASTER PERMIT COMMUNITY DEVELOPMENT Permit#: MST2020-00211 Date issued: Aug 3 2020 12:00AM T1GAtD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 parcel: 2S106AD05900 Jurisdiction: Tigard Site address: 12994 SW RIVER TERRACE BLVD Subdivision: RIVER TERRACE EAST Lot: 166 Project: SHANBHAG Project Description: Solar photovoltaic system. BUILDING Floor Areas Required Setbacks Required Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left: 0 Parking Spaces: 0 Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke Dwelling Units: 0 Third: 0 sf Right: 0 Detectors: Total: 0 sf Value: $2,000.00 Rear: 0 PLUMBING Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0 Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Storm Sewer: 0 Drains: 0 Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0 Other Fixtures: 0 Drywell-Trench Drain: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0 Heat Pump: N Hoods: 0 Other Units: 0 Furn<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 0 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add,500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401.600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Other: Y Other Description: Roof top PV system 6.4 kW Ecompasing: N BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: OTR SF VB R-3 0 Owner: Contractor: SHANBHAG,DAMODAR R&SNEHA D NATIONAL SOLAR Required Items and Reports(Conditions) 12994 SW RIVER TERRACE BLVD 320 SW CENTURY DRIVE 405-388 BEAVERTON,OR 97007 BEND,OR 97702 PHONE: 602-386-6758 PHONE: 206-877-2818 FAX: Total Fees: $353.69 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through A 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. Issued By: �4/t--t.�.(Gt d�y Permittee Signature: o� f L-f c�T'/O/�/ / J Call 503.639.4175 by 7:00 a.m.for the next available Inspection date. This permit card shall be kept in a conspicuous place on the Job site until completion of the project. Approved plans are required on the job site at the time of each inspection. r guilding Permit Application Residential RECEIVED FOR OFFICE USE ONLY 1NM'C •XIF City of Tigard 11 I 2020 Received 7 1 r 0, „ �.,,5.T /2 _, /t • I hone SW Hall Blvd,Tigard,OR 97223 Plan Review �/1 Phone' S03.718.2439 Fax: 503.598.196� i Ill Y .- ) Date/ByOther Perm�r. TIGARD Inspection Line: 503.639.4175 �,�j L�r ,I 1 tl�� �,,� Date ReadylBy. tvrr_s ® See Paget for Internet: www.tigard-or.gov Notified.�Method:97/3/ )O or,, Supplemental Information TYPE OF WORK REQUIRED DATA:t-AND 2-FAMILY DWELLING ❑New construction ❑Demolition Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all ❑Addition/alteration/replacement ®Other:Solar equipment,materials,labor,overhead,and the profit for the CATEGORY OF CONSTJ t TOv work indicated on this application. $.0 P s�M:nsaa.a,r -.nq . ® I-and 2-family dwelling Valuation: $2000.00 ❑Commercial/industrial ElAccessory building El Multi-familyNumber of bedrooms: ❑Master builder ❑Other: Number of bathrooms: JOB SFFE INFORMATION AND LOCATION Total number of floors: lob site address:12994 SW River Terrace Blvd. New dwelling area: square feet City/State/ZIP: Beaverton, OR 97007 Garage/carport area: square feet Suite/bldg./apt.no.: Project name:Solar for Shanbhag Covered porch area: square feet Cross street/directions to job site: SE of the intersection of SW Scholls Ferry Rd. Deck area: square feet and SW Roy Rogers Rd. Other structure area. square feet REQUIRED DATA:COMMERCIAL-USE CHECKLIST Subdivision: Lot no.: Permit fees*are based on the value of the work performed. Tax map/parcel no.:2S106AD05900 Indicate the value(rounded to the nearest dollar)of all equipment,materials,labor,overhead,and the profit for the' Fir DESCRIPTION OF WORK work indicated on this application. Installing 6.4kw solar pv system on roof of home. 20 REC 320NP modules Valuation: $ "�l and 10 Chilcon CP720 microinverters. Existing building area: square feet New building area: square feet ` I ® PROPERTY OWNER ❑ TENANT Number of stories: \V-`J Name:Damodar Shanbhag Type of construction: 1.1 Address:12994 SW River Terrace Blvd. Occupancy groups: City/State/ZIP: Beaverton, OR 97007 Existing: Phone:(602 )386-6758 Fax:( ) New: l APPLICANT ® CONTACT PERSON BUILDING PERMIT FEES* Business name:National Solar (Please refer to fee schedule) Structural plan review fee(or deposit): Contact name: Lynnette Harley Address:320 SW Century Dr. #405-388 FLS plan review fee(if applicable): Total fees due upon application: City/State/ZIP:Bend, OR 97702 k. Phone:(253 )359-1444 Fax: Amount received: E-mail Idharley@comcast.net PHOTOVOLTAIC SOLAR PANEL SYSTEM FEES* Commercial and residential prescriptive installation of `r \ CONTRACTOR roof-top mounted PhotoVoltaic Solar Panel System. vv Business name:National Solar Submit two(2)sets of roof plan with connection details and fire department access,along with the 2010 Oregon Address:320 SW Century Dr. #405-388 Solar Installation Specialty Code checklist. �•1 City/State/ZIP:Bend, OR 97702 Permit Fee(includes plan review $1 g0.00 and administrative fees): Phone:(503-) 915-6757 Fax:( )IV State surcharge(12%of permit fee): $21.60 Z. CCB tic.:186224 Total fee due upon application: $201.60 Authorized signature: This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. Print name: 2ITi Date 6/28/2020 *Fee methodology set by Tri-County Building Industry Service Board. I:\Building\Pe its1BUP-RESPermitA doe 02/24/201I 440-4613T(I1/02/COM/WEB) , Building Permit Application Checklist " One— and Two—Family Dwelling FOR OFFICE FSE ( SLI City of Tigardlig _ Received De eive Permit No.: • 13125 SW Hall Blvd.,Tigard,OR 97223 Associated permits: I Phone. 503.718.2439 Fax: 503.598.1960 24-Hour Inspection Line: 503.639.4175 0 Electrical ❑ Plumbing 0 Mechanical -I-IGAIt I) Internet: www.tigard-or.gov ❑ Other: THE FOLLOWING ITEMS ARE REQUIRED FOR PLAN REVIEW 1 es \o N/A 1 I.and use actions completed. See jurisdiction criteria for concurrent reviews. ❑ D 1 2 Zoning. Flood plain,solar balance points,seismic soils designation,historic district,etc. ❑ ❑ X❑ 3 Verification of approved plat/lot. 0 ❑ 0 4 Fire district approval required. Name of district: . 0 ❑ 5 Septic system permit or authorization for remodel. Existing system capacity 0 ❑ E 6 Sewer permit. ❑ ❑ E 7 Water district approval. ❑ ❑ 8 Soils report. Must carry original applicable stamp and signature on file or with application. 0 ❑ El 9 Erosion control 0 plan ❑permit required. Include drainage-way protection,silt fence design and location of catch- D 0 x❑ basin protection,etc. 10 3 Complete sets of legible plans. Must be drawn to scale,showing conformance to applicable local and state ® 0 0 building codes. Lateral design details and connections must be incorporated into the plans or on a separate full-size sheet attached to the plans with cross references between plan location and details. Plan review cannot be completed if copyright violations exist. 11 Site/plot plan drawn to scale. The plan must show lot and building setback dimensions;property corner elevations(if ® ❑ ❑ there is more than a 4-ft.elevation differential,plan must show contour lines at 2-ft.intervals);location of easements and driveway;footprint of structure(including decks);location of wells/septic systems;utility locations;direction indicator;lot area;building coverage area;percentage of coverage;impervious area;existing structures on site;and surface drainage. 12 Foundation plan. Show dimensions,anchor bolts,any hold-downs and reinforcing pads,connection details,vent size ❑ 0 ❑x and location. 13 Floor plans. Show all dimensions,room identification,window size,location of smoke detectors,water heater. 0 0 ❑x furnace,ventilation fans,plumbing fixtures,balconies and decks 30 inches above grade,etc. 14 Cross section(s)and details. Show all framing-member sizes and spacing such as floor beams,headers,joists,sub- 0 0 floor,wall construction,roof construction. More than one cross section may be required to clearly portray construction. Show details of all wall and roof sheathing,roofing,roof slope,ceiling height,siding material.. footings and foundation,stairs,fireplace construction,thermal insulation,etc. 15 Elevation views. Provide elevations for new construction;minimum of two elevations for additions and remodels. ❑ ❑ x❑ Exterior elevations must reflect the actual grade if the change in grade is greater than four foot at building envelope. Full-size sheet addendums showing foundation elevations with cross references are acceptable. 16 Wall bracing(prescriptive path)and/or lateral analysis plans. Must indicate details and locations;for non- ❑ 0 ❑x prescriptive path analysis provide specifications and calculations to engineering standards. 17 Floor/roof framing. Provide plans for all floors/roof assemblies,indicating member sizing,spacing,and bearing 0 0 x❑ locations. Show attic ventilation. 18 Basement and retaining walls. Provide cross sections and details showing placement of rebar. For engineered 0 0 ❑x systems,see item 22,"Engineer's calculations." 19 Beam calculations. Provide two sets of calculations using current code design values for all beams and multiple joists 0 0 x❑ over 10 feet long and/or any beam/joist carrying a non-uniform load. 20 Manufactured floor/roof truss design details. E 0 0 21 Energy Code compliance. Identify the prescriptive path or provide calculations. A gas-piping schematic is required ❑ 0 E for four or more appliances. 22 Engineer's calculations. When required or provided,(i.e.,shear wall,roof truss)shall be stamped by an engineer or ❑ 0 ❑x architect licensed in Ore•on and shall be shown to be a.rli cab le to the .ro'ect under review. JURISDICTIONAL SPECIFICS 23 Three(3)site plans are required for Item 11 above. Site plans must be 8-1/2"x I I"or 11"x 17". ❑ 0 0 24 Two(2)sets each are required for Items 16, 19,20 and 22 above. ❑ 0 0 25 Building plans shall not contain red lines or tape-ons. "Mirrored"building plans will not be accepted. 0 0 0 26 "Reversed"building plans must meet criteria outlined in the Permit&System Development Fees document. ❑ ❑ 0 27 "Drawn to scale"indicates standard architect or engineer scale. ❑ ❑ 0 28 Site plan to include tree size,type and location per approved project street tree plan(if applicable),and City of Tigard 0 0 0 Street Tree 1.ist. 29 Site plan to include trees and tree protection measures as required by conditions of approval. Tree locations,driplines, 0 0 ' 0 and protection measures must be drawn to scale and must include the project arborist's signature of approval. 30 A Clean Water Services'Sensitive Area Pre-Screening Site Assessment form is required for all building additions, ❑ ❑ ❑ including decks,patio covers(over non-impervious surface)and accessory structures to existing residential dwellings on a lot of record approved prior to September 9, 1995. I:\Building\Permits\BUP-RESPermitApp.doc 02/24/2011 440-4613T(1 I/02/COM/WEB) . , RECEIv r. Electrical Permit Application FOR OFFICE USE ONLY JUL 1 9 202 Received Permit 4. I City of Tigard 0 DateB : 13125 SW Hall Blvd.,Tigard,OR 97223 .' T1 f j,Y ,.I ,r„ g Plan Review Related Permit a: Phone: 503.718.2439 Fax. 503.598.19�»/p,_, Date/B Inspection Line: 503.639 4175 '1� LA V)„ ; ,/ Ready Date/By: Juds_ ® See Page 2 for TI GARD Internet. www.ligard-or.gov Notified/Method: Supplemental Information TYPE OF WORK , PLAN,SkyJEW El New construction ❑ Addition/alteration/replacement Please check all that apply Isubmit 2 sets of plans w/items checked). 0 Service or.feeder 400 amps or more 0 Building over three stories_ ❑ Detnoli Lion ® Other:Solar where the available fault current 0 Marinas and boatyards. CATEGORY OF CONSTRUCTION .,411.11111 exceeds 10,000 amps at 150 volts or 0 Floating buildings. ® I-and 2-family dwelling ❑ Commercial/industrial ❑Accessory building less to ground,or exceeds 14,000 0 Commercial-use agricultural amps for all other installations. buildings. ❑ Multi-family 0 Master builder ❑Other: 0 Fire pump. 0 Installation of 150 KVA or JOB SITE INFORMATION AND LOCATION ❑Emergency system. larger separately derived ['Addition of new motor load of system Job#: Job site address:12994 SW River Terrace Blvd. t0OHPor more . ❑"A"."E"."l-z", 1-s", City/State/ZIP: 0 Six or more residential units. occupancy. y Beaverton, OR 97007 ❑Health-care facilities. 0 Recreational vehicle parks. Suite/bldg• P #: Projectname:Suite/bldg./apt. S ❑Hazardous locations 0 Supply V oil age for more than Solar for hanbhaq ❑Service or feeder 600 amps in owte_ 600 volts nominal. Cross street/directions to job site: SE of the intersection of SW Scholls Ferry FEE SCHEDULE Description I Qty. I Each 1 Total Rd. and SW Roy Rogers Rd. New residential single-or multi-family dwelling unit. Subdivision: Lot#: Includes attached garage. 1,000 sq.0.or less 168.54 4 "lax map/parcel 4:2S 106AD05900 Ea.add'I 500 sq.ft.or portion 3392 1 DESCRIPTION, , ,O,' ." , „ , ,,.. Limited energy.residential (with above sq.ft.) 75 00 2 Installing 6.4kw solar pv system on roof of home. 20 REC 320NP Limited energy,multi-family modules and 10 Chilicon CP720 microinverters. residential(with above sq.ft.) 75.00 2 Renewable Energy ® See Page 2 ® PROPERTY OWNER 0 TENANT Services or feeders installation,alteration,and/or relocation Name:Damodar Shanbhag 200 amps or less 100.70 2 201 amps to 400 amps 133.56 2 Address:12994 SW River Terrace Blvd. 401 amps to600 amps 200.34 2 City/State/ZIP: Beaverton, OR 97007 601 amps to 1,000 amps 301.04 2 Phone:(602 )386-6758 Fax:( ) Over 1,000 amps or volts 552.26 2 Temporary services or feeders installation,alteration,and/or Email:damsfact@gmail.com relocation Owner installation:This installation is being made on property that I own which is not 200 amps or less 59.36 1 intended Tor sale,lease,rent,or exchange,according``- �toL ORS 447,449,670,and 701. 201 amps to 400 amps 125.08 2 Owner signature: Paint.9 /�Z4 Date: 6/28/2020 401 amps to 599 amps 168.54 2 ® APPLICANT_ „" CONTACT PERSON Branch circuits-new,alteration,or extension, .er panel A.Fee for branch circuits with Business name:National Solar above service or feeder fee, 742 2 _ ._ _ each branch circuit Contact name:Lynnette Harley B.Fee for branch circuits without service or feeder fee,first 56.18 2 Address:320 SW Century Dr. #405-388 branch circuit City/State/ZIP:Bend, OR 97702 Each add'I branch circuit 7.42 2 Miscellaneous(service or feeder not included) Phone:( 2531359-1444 Fax: :( ) Each manufactured or modular 67 84 2 Email: dwelling,service and/or feeder Idharlevc comcast.net Reconnect only 67.84 2 CONTRACTOR Pump or irrigation circle 67.84 2 Business name:National Solar Sign or outline lighting 67.84 2 Signal circuit(s)or limited-energy 0 See Page 2 2 Address:320 SW Century Dr. #405-388 panel,alteration,or extension. City/State/ZIP: Bend, OR 97702 Each additional inspection over allowable in any of the above Additional inspection(1 hr min) 66.25/hr Phone:(503-) 915-6757 Fax:( ) Investigation(I hr min) 90.00/hr Email:john@nationalsolarusa.com Inspectionsl fnrt(1 whichhr no) 78.18/hr Inspections for no fee is 90 00/hr CCB Lie.: 186224 Electrical Lie.:C1512 Suprv.Lie.:6051 S specifically listed('/hr min) ELECTRICAL PERMIT FEES Suprv.Electrician signature,required: _ O Subtotal: Print name: Cody Oram Date:6/28/2020 0 Plan Review Required(25%of permit fee): State surcharge(12%of permit fee): Authorized signature: TOTAL PERMIT FEE: ity../1.4.t. �/ This permit application expires if a permit is not obtained within 180 Print name: ri Date:6/28/2020 days after it has been accepted as complete. _[Ea c Number of inspections allowed per permit IdeuildingAPermitsAErmilApp_ELR_EREdoc r t16/17/2015 440-1615TO1/l15/CCM/WEB 6 Electrical Permit Application—City of Tigard Page 2—Supplemental Information Limited Energy Permit Fees: Renewable Energy Permit Fees: RESIDENTIAL WORK ONLY: <. FEE SCHEDULE Description Qty. I Each 7"6"Etttl'` I Fee for all residential systems combined: $75.00 Renewable electrical energy systems: Check Type of Work Involved: 5 kva or less 100.70 2 5.01 to 15 kva t 133.56 2 ❑ Audio and Stereo Systems*. 15.01 to 25 kva 200.34 2 Wind generation systems in excess of 25 kva: ❑ Burglar Alarm 25.01 to 50 kva 301.04 2 50.01 to 100 kva 552.26 2 ❑ Garage Door Opener* >100 kva(fee in accordance 552.26 2 with OAR 918-309-0040) ❑ Heating, Ventilation and Air Conditioning Solar generation systems in excess of 25 kva: System* Each additional kva over 25 7.42 3 n Vacuum Systems* >100 kva—no additional charge 0.0 3 Each additional inspection over allowable in any of the above: ✓ Other: Solar Each additional inspection is 66.25/hr charged at an hourly(1 hr min) Inspections for which no fee is 90 00/hr specifically listed(' hr min) COMMERCIAL WORK ONLY: ELECTRICAL PERMIT FEES ' Fee for each commercial system: $75.00 Subtotal(Enter on Page l): * Number of inspections allowed per permit. (SEE OAR 918-309-0000) Check Type of Work Involved: ❑ Audio and Stereo Systems n Boiler Controls ❑ Clock Systems ❑ Data Telecommunication Installation ❑ Fire Alarm Installation HVAC ❑ Instrumentation ❑ Intercom and Paging Systems n Landscape Irrigation Control* ❑ Medical IT N• urse Calls n O• utdoor Landscape Lighting* ❑ Protective Signaling ❑ Other: Total number of commercial systems: *No licenses are required. Licenses are required for all other installations 19Buildins Pernsils\ELC_PenniiApp_ELR_ERE.doc Rev 0r517/2015 REaCErlfl, City of Tigard JUL 1 g 2020 Building Division UT"( J1- 13125 SW Hall Blvd,Tigard,OR 97223 Phone: 503.718.2439 Fax: 503.598.1960 T I G A R D Inspection Line: 503.639.4175 www.tigard-or.gov 2010 Oregon Solar Installation Specialty Code Check List for Prescriptive Installation of Roof-Mounted PhotoVoltaic Solar Panel System Property Information Installation Address: 12994 SW River Terrace Blvd. City: Beaverton (within Tigard city limits) Zip: 97007 Owner's Name: Damodar Shanbhag Date: 6/22/2020 Contractor's Name: National Solar CCB #: 186224 Design Parameters of the Property/Structure If"Yes", does not Flood Hazard Is the installation Yes qualify for the Area Located in a flood prescriptive path, follow plain/flood way? R" No OSSC or ORSC for design requirements. EX Is the wind exposure Yes If"Yes", qualifies for Wind Exposure "C"or less? ❑ No the prescriptive path. Installations on detached Is the Ground Snow single/two-family Load 70 psf or less? dwelling/single/two- If"Yes", qualifies for family townhomes ® Yes the prescriptive path. and/or their accessory Ground structures. ❑ No Snow Load Is the Ground Snow Installations on all Load 50 psf or less? If"Yes", qualifies for structures other than ❑ Yes the prescriptive path. above ❑ No 1 I:/Bui Iding/Fonns/PhotoVoltaic-Checklist02-01-11.docx Is the construction X❑ Yes Type of material wood and does If"Yes", qualifies for the construction qualify Construction ❑ No the prescriptive path. as"conventional light frame"construction? Is the spacing 24 inches or less? If Pre-engineered trusses. ® Yes "Yes",qualifies for the prescriptive path. ❑ No Roof framing members Is the spacing 24 inches or less? If"Yes",qualifies for Nominal lumber. ❑X Yes the prescriptive path. ❑ No Is the combined weight ❑X Yes of the PV modules and If"Yes",qualifies for racking less than or ❑ No the prescriptive path. Solar equal to 4.5 psf? installation Is the solar installation layout in accordance X Yes with Section 305.4(3)of If"Yes",qualifies for the 2010 Oregon Solar ❑ No the prescriptive path. Code? ❑ Metal Single layer If roofing material is Roofing Check the type of ❑ of wood one of the three types material roofing material shingle/shake checked,qualifies for Max. two layers the prescriptive path. ❑x of composition shingle. Is the roof mounted Yes Connections of solar assembly If"Yes", qualifies for the solar assembly connected to roof ❑ No to the roof framing or blocking the prescriptive path. directly? 2 l:/Bui Iding/Forms/Photo Vol taic-Checklist02-0I-I 1.docx ❑ Yes If"Yes", qualifies for Is the gauge 26 or less? ❑ No the prescriptive path. 115 lbs for 60 inch spacing or less? If"Yes", qualifies for ❑ Yes the prescriptive path. ❑ No Minimum Uplift rating of Clamps? 75 lbs for 48 inches spacing or less? If"Yes",qualifies for ❑ Yes the prescriptive path. ❑ No Attachment of roof mounted Minimum 24 inches If the spacing falls solar systems Spacing of clamps? within 24 inches and 60 directly to inches Maximum 60 inches inches,qualifies for the standing seam prescriptive path. metal panels If the width of the panel P Width of roofing is less than 18 inches, panels? 18 inches or less qualifies for the inches prescriptive path. Minimum#10 at 24 inches o/c? Size and spacing of If"Yes",qualifies for fastener? El Yes the prescriptive path. ❑ No is the roof decking of WSP min. 'Y2"thickness, Yes decking connected to If"Yes", qualifies for framing members ❑ No the prescriptive path. w/min. 8d nails @ 6"/12"o/c? Is the height less than or Maximum 18 inches equal to 18 inches? Height of the from the top of the If"Yes",qualifies for solar modules module to the roof ® Yes the prescriptive path. surface. ❑ No 3 I:/Building/Forms/Photo Voltaic-ChecklistO2-01-1 I.docx Submittal Documents required for Prescriptive Installations Show the location of the PV system in relation to buildings, structures, property lines, and,as applicable, flood hazard areas. Site Plan Details must be clear and easy to read. Minimum size of the plan is 8.5 x 11 inches. Attach a simple structural plan showing the roof framing(rafter size,type, and spacing)and PV module system racking attachment. System must be shown in sufficient detail and clarity to assess whether it Structural Plan meets the prescriptive construction requirements as listed earlier above in the matrix. Minimum size of the plan is 8.5 x 11 inches. PV Modules Manufacturer: REC Solar Model Number: REC320NP Black Listing Agency: UL 4 L/Bui Iding/Forms/Photo Voltaic-Checklist02-01-11.docx