Permit u CITY OF TIGARD MASTER PERMIT
I ' COMMUNITY DEVELOPMENT Permit#: MST2020-00205
Date Issued: Jul 31 2020 12:00AM
TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Parcel: 2S106DA09200
Jurisdiction: Tigard
Site address: 16794 SW SNOWDALE ST
Subdivision: RIVER TERRACE EAST Lot: 92
Project: Shukla
Project Description: Solar photovoltaic system.
BUILDING
Floor Areas Required Setbacks Required
Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left 0 Parking Spaces: 0
Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke
Dwelling Units: 0 Third: 0 sf Right: 0 Detectors:
Total: 0 sf Value: $24,000.00 Rear: 0
PLUMBING
Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0
Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Storm Sewer: 0
Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Drains: 0 Catch Basins: 0
Bckflw Prevntr: 0
Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0
Drywell-Trench Drain: 0 Other Fixtures: 0
Other Fixture Units:
MECHANICAL
Fuel Types Alr Conditioning: N Vent Fans: 0 Clothes Dryers: 0
Heat Pump: N Hoods: 0 Other Units: 0
Furn<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0
Furn>=100K: 0
ELECTRICAL
Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits
1000 sf or less: 0 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0
Ea add l 500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0
Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0
601-1000 amp: 0 601+amp-1000v: 0
1000+amp/volt: 0
ELECTRICAL-RESTRICTED ENERGY
SF Residential
Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All
Other: Y Other Description: Roof Top Solar PV System 10.56 kW Ecompasing: N
BUILDING INFO
Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet:
OTR SF VB R-3 0
Owner: Contractor:
SHUKLA,YATIN J NATIONAL SOLAR Required Items and Reports(Conditions)
NARAYAN,URJA V 320 SW CENTURY DRIVE 405-388
16794 SW SNOWDALE ST BEND,OR 97702
BEAVERTON,OR 97007
PHONE: 662-703-0103 PHONE: 206-877-2818
FAX:
Total Fees: $352.69
This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will
be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180
days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR
952-001-0010 throug R 952-0/0111/Q�ii9�. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344.j
Issued By: C/. Permittee Signature: O� 'J a/'"f L/C'jr IO/✓
Call 503.639.4175 by 7:00 a.m.for the next available Inspection date.
This permit card shall be kept in a conspicuous place on the job site until completion of the project.
Approved plans are required on the job site at the time of each inspection.
•
Building Permit Application
Residential nECE1�fED FOR OFFICE USE ONLY
City of Tigard ��JJ yUq Received #2.0 / o�
II • 13125 SW Hall Blvd.,Tigard,OR 9722i�UL q L0L0 Plan Revie� IJ ^l�
C Phone: 503.718.2439 Fax: 503.598.1960 Date/By: ff7! Other Permit:
Inspection Line. 503.639 4175 7 k Date Ready/By: km.. la See Page 2 for
TIGARD CITY OF TIG�(ARD / g
Internet: wwvv.tigard-or.gov BUILDI1tiG DIVISION Notified./Method: N[ U Supplemental Information
rL ?r- 'f- LY'n!n/EtjC--
PE OF WORK rt;. REQUIRED DATA:1-AND 2-FAMILY DWELLING
D New construction ❑Demolition Permit fees*are based on the value of the work performed.
Indicate the value(rounded to the nearest dollar)of all
0 Addition/alteration/replacement ®Other:Solar equipment,materials,labor,overhead,and the profit for the
CATEGORY OF CONSTRUCTIONy work indicated on this application.
El1-and 2-family dwelling ❑Commercial/industrial Valuation: $24000.00
❑Accessory building ❑Multi-family Number of bedrooms:
❑Master builder ❑Other: Number of bathrooms:
a ..,, ... _. JOB SITE INFORMATION 4ND LOCATION ,,, Total number of floors:
Job site address:16794 SW Snowdale St. New dwelling area: square feet
City/State/ZIP:Tigard, OR 97223 Garage/carport area: square feet
Suite/bldg./apt.no.: Project name:Solar for Shukla Covered porch area: square feet
Cross street/directions to job site: SE of the intersection of SW Scholls Ferry Rd. Deck area: square feet
and SW Roy Rogers Rd. Other structure area: square feet
REQUIRED DATA:COMMERCIAL-USE CHECKLIST
Subdivision: J I.ot no.: Permit fees*are based on the value of the work performed.
Tax map/parcel no..2S106DA09200 Indicate the value(rounded to the nearest dollar)of all
equipment,materials,labor,overhead,and the profit for the
DESCRIPTION OF WORK work indicated on this application.
Installing 10.56kw solar pv sysem on roof of home. Valuation: $
33 REC 320NP modules and 17 Chilicon CP720 microinverters. Existing building area: square feet
New building area: square feet
® PROPERTY OWNER 0 TENANT Number of stories:
Name:Yatin Shukla Type of construction:
Address:16794 SW Snowdale St. Occupancy groups:
City/State/ZIP:Tigard, OR 97223 Existing:
Phone:(662 )703-0103 Pax:( )
New:
® APPLICANT ® CONTACT PERSON BUILDI1Vte„ ERMIT FEES* ,31-,
(Please refei'to fee schedule)
Business name:National Solar
Structural plan review fee(or deposit):
Contact name:Lynnette Harley/John Harley
FLS plan review fee(if applicable):
Address:13521 174th St. Ct. E.
Total fees due upon application:
City/State/ZIP:Puyallup,WA 98374
Amount received:
Phone:(253-)359-1444 Fax::( )
E-mail:Idharley@comcaSt.net PHOTOVOLTAIC SOLAR PANEL SYSTEM FEES*
CONTRACTOR Commercial and residential prescriptive installation of
roof-top mounted PhotoVoltaic Solar Panel System.
Business name:National Solar Submit two(2)sets of roof plan with connection details
and fire department access,along with the 2010 Oregon
Address:320 SW Century Dr. #405-388 Solar Installation Specialty Code checklist.
City/State/ZIP:Bend, OR 97702 Permit Fee(includes plan review $180.00
and administrative fees):
Phone:(503-)915-6757 Fax:( ) State surcharge(12%of permit fee): $21.60
CCB lie.:186224 Total fee due upon application: $201.60
Authorized signature: )49�7 , This permit application expires if a permit is not obtained
within 180 days after it has been accepted as complete.
Print name:John Harley Date:7/2/2020 *Fee methodology set by Tri-County Building Industry
Service Board.
I:1Building\Permits1BUP-RESPermitApp.doc 02/24/2011 440-4613T(I l/02/COM/WEB)
Building Permit Application Checklist
One- and Two-Family Dwelling FOR OFFICE USE ONLY
City of Tigard
Received
Date/By: Pe Permit No
13125 S W Hall Blvd.,Tigard,OR 97223 Associated permits:
. Phone: 503.718 2439 Fax: 503.598.1960
24-Hour Inspection Line. 503.639 4175 ❑ Electrical 0 Plumbing ❑ Mechanical
T I G A li I) Internet: www.ligard-or.gov ❑ Other:
THE FOLLOWING ITEMS ARE REQUIRED FOR PLAIN REVIEW 'es No N/.1
I Land use actions completed. See jurisdiction criteria for concurrent reviews. ❑ ❑ tY
2 Zoning. Flood plain,solar balance points,seismic soils designation,historic district,etc. ❑ , ❑ E
3 Verification of approved plat/lot. ❑ ❑ E
4 Fire district approval required. Name of district: 0 0 E
5 Septic system permit or authorization for remodel. Existing system capacity ❑ 0 Ed
6 Sewer permit. 0 0
7 Water district approval. ❑ ❑ E
8 Soils report. Must carry original applicable stamp and signature on file or with application. ❑ 0
9 Erosion control ❑plan ['permit required. Include drainage-way protection,silt fence design and location of catch- 0 ❑ x❑
basin protection,etc.
10 3 Complete sets of legible plans. Must be drawn to scale,showing conformance to applicable local and state ❑x 0 ❑
building codes. Lateral design details and connections must be incorporated into the plans or on a separate full-size
sheet attached to the plans with cross references between plan location and details. Plan review cannot be completed if
copyright violations exist.
11 Site/plot plan drawn to scale. The plan must show lot and building setback dimensions;property corner elevations(if x❑ 0 0
there is more than a 4-ft.elevation differential,plan must show contour lines at 2-ft.intervals);location of easements
and driveway;footprint of structure(including decks);location of wells/septic systems;utility locations;direction
indicator;lot area;building coverage area;percentage of coverage;impervious area;existing structures on site;and
surface drainage.
12 Foundation plan. Show dimensions,anchor bolts,any hold-downs and reinforcing pads,connection details,vent size ❑ ❑ 0
and location.
13 Floor plans. Show all dimensions,room identification,window size,location of smoke detectors,water heater, 0 0 x❑
furnace,ventilation fans,plumbing fixtures,balconies and decks 30 inches above grade,etc.
14 Cross section(s)and details. Show all framing-member sizes and spacing such as floor beams,headers,joists,sub- 0 0
floor,wall construction,roof construction. More than one cross section may be required to clearly portray
construction. Show details of all wall and roof sheathing,roofing,roof slope,ceiling height,siding material,footings
and foundation,stairs,fireplace construction,thermal insulation,etc.
15 Elevation views. Provide elevations for new construction;minimum of two elevations for additions and remodels. 0 ❑
Exterior elevations must reflect the actual grade if the change in grade is greater than four foot at building envelope.
Full-size sheet addendums showing foundation elevations with cross references are acceptable.
16 Wall bracing(prescriptive path)and/or lateral analysis plans. Must indicate details and locations;for non- 0 0 ❑x
prescriptive path analysis provide specifications and calculations to engineering standards.
17 Floor/roof framing. Provide plans for all floors/roof assemblies,indicating member sizing,spacing,and bearing 0 0 LE
locations. Show attic ventilation.
18 Basement and retaining walls. Provide cross sections and details showing placement of rebar. For engineered 0 ❑ El
systems,see item 22,"Engineer's calculations."
19 Beam calculations. Provide two sets of calculations using current code design values for all beams and multiple joists 0 0 E
over 10 feet long and/or any beam/joist carrying a non-uniform load.
20 Manufactured floor/roof truss design details. ❑x ❑ 0
21 Energy Code compliance. Identify the prescriptive path or provide calculations. A gas-piping schematic is required ❑ ❑ ❑x
for four or more appliances.
22 Engineer's calculations. When required or provided,(i.e.,shear wall,roof truss)shall be stamped by an engineer or 0 0 x❑
architect licensed in Ore•on and shall be shown to be applicable to the •ro'ect under review.
JURISDICTIONAL SPECIFICS
23 Three(3)site plans are required for Item 11 above. Site plans must be 8-1/2"x 11"or 11"x 17". 0 0 x❑
24 Two(2)sets each are required for Items 16, 19,20 and 22 above. 0 ❑ x❑
25 Building plans shall not contain red lines or tape-ons. `Mirrored"building plans will not be accepted. 0 0 ❑
26 "Reversed"building plans must meet criteria outlined in the Permit&System Development Fees document. 0 ❑ x❑
27 "Drawn to scale' indicates standard architect or engineer scale. ❑ ❑ x❑
28 Site plan to include tree size,type and location per approved project street tree plan(if applicable).and City of Tigard ❑ 0 Iji
Street Tree List.
29 Site plan to include trees and tree protection measures as required by conditions of approval. Tree locations,driplines, ❑ ❑ x❑
and protection measures must be drawn to scale and must include the project arborist's signature of approval.
30 A Clean Water Services'Sensitive Area Pre-Screening Site Assessment form is required for all building additions, 0 0 0
including decks,patio covers(over non-impervious surface)and accessory structures to existing residential dwellings
on a lot of record approved prior to September 9, 1995.
I.1Building1 Permits 1BUP-RESPermitApp.doc 02/24/2011 440-4613T(I I/02/COM/WEB)
CF �
Electrical Permit Applicatio�E �d�- .t-7. FOR OFFICE USE ONLY
City of Tigard JUL a'?(�,00 Received
Date/B Permit#.
13125 SW Hall Blvd.,Tigard,OR 97223 Plan Review
Phone: 503.718.2439 Fax: 503.598.19(70Ph
DatelB : Related Permit#:
Inspection Line: 503.639.4175 t Ready Date/By: inns: El See Page 2 for
1 I GA RU Internet. www.tigard-or.gov Bli11 L"a a7 �ll yr JluN Notified/Method: Supplemental Information
TYPE OF WORK ,... : ry PLAAAAAAAPEVIEW t.x„,.,e,. 1 x, ,,.
❑New construction El Addition/alteration/replacement Please check all that apply(submit 2 sets ofplzns w/items checked).
�I Solar ❑Service or feeder 400 amps or more 0 Building over three stories.
❑ Demolition El Other: where the available fault current ❑Marinas and boatyards.
CATEGORY OF CONSTRUCTION exceeds 10,000 amps at 150 volts or ❑Floating buildings.
® 1-and 2-family dwelling 0 Commercial/industrial ❑Accessory building less to ground,or exceeds 14,000 0 Commercial-use agricultural
amps for all other installations. buildings.
❑ Multi-family ❑Master builder ❑Other: 0 Fire pump. ['Installation of 150 KVA or
JOB SITE INFORMATION AMIKICATION 0 Emergency system. larger separately derived
AddJob#: Job site address:16794 SW Snowdale St. ❑loOHp n of new motor load of system.
OOHP or more. ❑"A" "E"."1-2" "1 3"
City/State/ZIP:Tigard, OR 97223 ❑Six or more residential units. occupancy.
❑Health-care facilities. 0 Recreational vehicle parks.
Suite/bldg./apt.#: Project name:Solar for Shukla ❑Hazardous locations. 0 Supply voltage for more than
❑Service or feeder 600 amps re more 600 volts nominal.
Cross street/directions to job site: SE of the intersection of SW Scholls SIM, , Fgg SCHEDULE
Ferry Rd. and SW Roy Rogers Rd. Description I Qtr. I Each Total
New residential single-or multi-family dwelling unit.
Subdivision: Lot#: Includes attached garage.
1,000 sq ft or less 168.54 4
Tax map/parcel#:2S106DA09200 Ea.add'I 500 sq.ft.or portion 33.92 1
DESCRIPTION OF,WOR41111111= Limited energy,residential 75.00 2
Installing 10.56kw solar pv sysem on roof of home. (with above sq.ft.)
Limited energy,multi-family 75.00 2
33 REC 320NP modules and 17 Chilicon CP720 microinverters. residential(with above sq.ft.)
Renewable Energy ❑ See Page 2
.s,a.: ® PROPERTY OWNER v TENANT Services or feeders installation,alteration,and/or relocation
Name:Yatin Shukla 200 amps or less 100.70 2
_
Address:16794 SW Snowdale St. 201 amps to 400 amps 133.56 2
401 amps to 600 amps 200.34 2
City/State/ZIP:Tigard, OR 97223 601 amps to 1,000 amps 301.04 2
Phone:(662 )703-0103 Fax:( ) Over 1,000 amps or volts 552 26 2
Temporary services or feeders installation,alteration,and/or
Email:yatin.shukla@gmail.com relocation
Owner installation:This installation is being made on property that I own which is not 200 amps or less 59.36 1
intended for sale,lease,rent,or exchange,according to ORS 447,449.670,and 701. 201 amps to 400 amps 125.08 2
Owner signature: _ Date: 401 amps to 599 amps 168.54 2
0 APPLICANT
® CONTACT PERSON Branch circuits—new,alteration,or extension,per panel
A.Fee for branch circuits with
Business name:National Solar above service or feeder fee, 742
--_. each branch circuit
Contact name:Lynnette Harley/John Harley B.Fee for branch circuits without
Address:13521 174th St. Ct. E. service or feeder fee,first branch 2
branch circuit
City/State/ZIP:Puyallup, WA 98374 Each add'l branch circuit 7.42 2
Miscellaneous(service or feeder not included)
Phone:(253-)359-1444 Fax::( ) Each manufactured or modular
67.84 2
dwelling,service and/or feeder
Email:ldharley@comcast.net Reconnect only 67.84 2
CONTRACTOR Pump or irrigation circle 67.84 2
Business name:National Solar Sign or outline lighting 67.84 2
Signal circuit(s)or limited-energy
Address:320 SW Century Dr. #405-388 panel,alteration,or extension. 1 'Page 2 2
City/State/ZIP:Bend, OR 97702 Each additional inspection over allowable in any of the above
Additional inspection(I hr rain) 66.25/hr
Phone:603-)915-6757 Fax:( ) Investigation(1 hr min) 90.00/hr
Industrial plant(1 hr min) 78.18/hr
Email:john@natlOnalSOlarUSa.COm Inspections for which no fee is -
CCB Lie.:186224 Electrical Lie.:Cl 51 2 Suprv.Lie.:6051 S specifically listed i'%i hr min) 90 00i hr
ELECTRICAL PERMIT FEES
Suprv.Electrician signature,required: �L11-taL Subtotal:
Print name: Cody Oram Date:7/2/2020 ❑Plan Review Required(25%of permit fee):
` State surcharge(12%of permit fee):
Authorized signature: /lit' TOTAL PERMIT FEE:
This permit application expires if a permit is nut obtained within 180
Print name:John Harl y Date:7/2/2020 days after it has been accepted as complete.
* Number of inspections allowed per permit.
itBuilding/Permits\ELC_PermitApp_ELR_ERE.dee Res OW I7/n115 440-4615T(II/05/COMMEB
Electrical Permit Application —City of Tigard
Page 2—Supplemental Information
Limited Energy Permit Fees: Renewable Energy Permit Fees:
RESIDENTIAL WORK ONLY: FEE SCHEDULE
Drscriplion I Qty. I Each Total
Fee for all residential systems combined: $75.00 Renewable electrical energy systems:
5 kva or less 100.70 2
Check Type of Work Involved:
5.01 to 15 kva 1 133.56 2
n Audio and Stereo Systems* 15.01 to 25 kva 200.34 2
Wind generation systems in excess of 25 kva:
❑ Burglar Alarm 25.01 to 50 kva 301.04 2
50.01 to 100 kva 552.26 2
Garage Door Opener* >100 kva(fee in accordance
with OAR 918-309-0040) 552.26 2
❑ Heating, Ventilation and Air Conditioning Solar generation systems in excess of 25 kva:
System* Each additional kva over 25 7.42 3
n Vacuum Systems* >100 kva-no additional charge 0.0 3
Each additional inspection over allowable in any of the above:
n Other: Solar Each additional inspection is 66 25!hr 1
charged at an hourly(1 hr min)
Inspections for which no fee is 90 00!hr
srecificall listed('L hr min)
COMMERCIAL WORK ONLY: ELE4? u T.
Subtotal
a. enter on
Fee for each commercial system: $75.00 alowedlerpermt. Page I)
y Number of mspechons allowed per permit.
(SEE OAR 918-309-0000)
Check Type of Work Involved:
❑ Audio and Stereo Systems
n Boiler Controls
n Clock Systems
n Data Telecommunication Installation
❑ Fire Alarm Installation
n HVAC
❑ Instrumentation
❑ Intercom and Paging Systems
n Landscape Irrigation Control*
n Medical
❑ Nurse Calls
n Outdoor Landscape Lighting*
n Protective Signaling
❑ Other:
Total number of commercial systems:
*No licenses are required. Licenses are required for all
other installations
I:1Building\Pumas\ELC_PermiiApp_ELR_ERE.doc Res I/6/17,2015
City of Tigard 6 riCIV
M Building Division JUL x2020
13125 SW Hall Blvd,Tigard,OR 97223 FPD
Phone: 503.718.2439 Fax: 503.598.1960 CITY OF TIGARD
T I G A R D Inspection Line: 503.639.4175
BUM,'•:.r C-Ti;3!ON
www.tigard-or.gov
2010 Oregon Solar Installation Specialty Code
Check List for Prescriptive Installation of Roof-Mounted
PhotoVoltaic Solar Panel System
Property Information
Installation Address: 16794 SW Snowdale St.
City: Tigard Zip: 97223
Owner's Name: Yatin Shukla Date: 7/1/2020
Contractor's Name: National Solar CCB #: 186224
Design Parameters of the Property/Structure
If"Yes",does not
Is the installation qualify for the
Flood Hazard Yes
Located in a flood ❑ prescriptive path, follow
Area plain/flood way? D No OSSC or ORSC for
design requirements.
Is the wind exposure ® Yes If"Yes",qualifies for
Wind Exposure "C"or less? ❑ No the prescriptive path.
Installations on detached Is the Ground Snow
single/two-family Load 70 psf or less?
dwelling/single/two- If"Yes", qualifies for
family townhomes ❑X Yes the prescriptive path.
and/or their accessory
Ground structures. ❑ No
Snow Load Is the Ground Snow
Installations on all Load 50 psf or less?
If"Yes", qualifies for
structures other than
® Yes the prescriptive path.
above
❑ No
1
LBui Iding/Fonns/PhotoVoltaic-Checklisto2-0 I-11.docx
Is the construction
Type of material wood and does Yes If"Yes",qualifies for
the construction qualify El No the prescriptive path.
Construction as"conventional light
frame"construction?
Is the spacing 24 inches
or less?
Pre-engineered trusses. ® Yes If"Yes", qualifies for
the prescriptive path.
❑ No
Roof framing
members Is the spacing 24 inches
or less?
If"Yes",qualifies for
Nominal lumber. ® Yes the prescriptive path.
❑ No
Is the combined weight ® Yes
of the PV modules and If"Yes",qualifies for
racking less than or ❑ No the prescriptive path.
Solar equal to 4.5 psf?
installation Is the solar installation
layout in accordance Yes If"Yes", qualifies for
with Section 305.4(3)of
the 2010 Oregon Solar ElNo the prescriptive path.
Code?
❑ Metal
Single layer If roofing material is
Roofing Check the type of ❑ of wood one of the three types
material roofing material shingle/shake checked, qualifies for
Max.two layers the prescriptive path.
❑X of composition
shingle.
Is the roof mounted ® Yes
Connections of solar assembly
the solar assembly connected to roof If"Yes",prescriptiveqp path.
for
❑ No the path.
to the roof framing or blocking
directly?
2
I:Building/Forms/Photo V oltai c-Checkl i st02-01-11.doc x
•
❑ Yes If"Yes", qualifies for
Is the gauge 26 or less? ❑ No the prescriptive path.
115 lbs for 60 inch
spacing or less?
If"Yes", qualifies for
❑ Yes the prescriptive path.
❑ No
Minimum Uplift rating
of Clamps? 75 lbs for 48 inches
spacing or less?
If"Yes",qualifies for
❑ Yes the prescriptive path.
❑ No
Attachment of
roof mounted Minimum 24 inches If the spacing falls
solar systems Spacing of clamps? within 24 inches and 60
directly to inches Maximum 60 inches inches, qualifies for the
standing seam prescriptive path.
metal panels Width of roofing If the width of the panel
panels? 18 inches or less is less than 18 inches,
inches qualifies for the
prescriptive path.
Minimum#10 at 24
inches o/c?
Size and spacing of If"Yes", qualifies for
fastener? ❑ Yes the prescriptive path.
❑ No
Is the roof decking of
WSP min. '/2"thickness, ❑ Yes
decking connected to If"Yes",qualifies for
framing members ❑ No the prescriptive path.
w/min. 8d nails @
6"/12" o/c?
Is the height less than or
Maximum 18 inches equal to 18 inches?
Height of the from the top of the If"Yes",qualifies for
solar modules module to the roof Yes the prescriptive path.
surface. No
3
1JBuilding/Fotms/Photo V oltaic-Checkli st02-01-I I.docx
•
Submittal Documents required for Prescriptive Installations
Show the location of the PV system in relation to buildings, structures,
property lines, and,as applicable,flood hazard areas.
Site Plan Details must be clear and easy to read.
Minimum size of the plan is 8.5 x 11 inches.
Attach a simple structural plan showing the roof framing(rafter size,type, and
spacing)and PV module system racking attachment.
System must be shown in sufficient detail and clarity to assess whether it
Structural Plan meets the prescriptive construction requirements as listed earlier above in the
matrix.
Minimum size of the plan is 8.5 x 11 inches.
PV Modules
Manufacturer: REC Solar
Model Number: REC320NP Black
Listing Agency: UL
4
1:/Bui Iding/FormsfPhoto Voltaic-Checklist02-01-I 1.docx