Plans (2) Job: Shukla • 16794 SW Snowdale St. OFFICE '''`1PY •N Tigard, OR 97223 JUL �4.- SW Snowdale St. 2.020 ch` ' `�.CiA�D CITY OF TIGARD BUILc; ;a c;��Isl ,v REVIEWED FOR CODE COMPIJANCE Approved: [ OTC: [ ] Driveway Permit#: m612 1D' Db 1b' Address: \l r19 Li 5\,..) t --9 \ / Suite #: I B : tM k Date:-VI 3 Zdlm AC Disconnect & OCPDs —6\_ next to Utility/Net Meter >,2„from ridge Backed to main panel in garage Section3111.4.8.1 Suneye 2 1 LIABILITY The City of Tigard and its Suneye 1 (33) REC320NP Solar panels employees shall not be Modules 40"x65" responsible for discrepancies W micro inverters under modules which may appear herein, attachmenst every 4' 2-story composition roof material, 26 deg slope or 2' when within 3' or ridge or edge VALIDITY OF PERT Approved plan; THE ISSUANCE OF A PERMIT shall be on job site. BASED ON CONSTRUCTION DOCUMENTS AND OTHER DATA SHALL NOT PREVENT THE CODE OFFICIAL FROM REQUIRING THE CORRECT IO • OF ERRORS. ORSC 10°. ' Job: Job: Shukla 16794 SW Snowdale St. ELEVATION Tigard, OR 97223 <18" Section 305.4 PV Module / SPANS , 6' r EZ roof mount /� 6' 2x4 engineered attachment ',� 7 6' F truss @ 24" OC Rafter 26° 26° 28' Ext. Wall 10' Spans comply with Table 802.5.1(3) Comp roof, one layer Sunmodo EZ roof mount attachments: UL2703 Compliant Rafters @ 24" OC L-Foot 9/16" hex bolt EZ roof mount Attachments J �I! @ 48" OC PV Module 2" Stand off Aluminum Sunmodo rail 4" x 5/16" lag bolt Flashing I II IN IP 1 Micro inverter, 1 per 2 modules Aluminum roof shoe Rafter (under flashing) Conductors=#10 AWG THHN in 3/4"EMT or FMC Ground #6AWG Utility/Net meter PV PV PV PV • Neurtal #10AWG Connected via supply line tap Module Module Module Module Distance 60' NEC 230.82(6)&705.12 #6AWG • I0 / // MI _ — ^ I Ilk • Square D m©8" Inverter Cable Breaker box with 18 Modules with a total o Black-Li 9 CP720 Micros Red-L2 branch OCPDs 60A AC Disconnect White-G V-N Greenw/60A rated fuses 200A 30A 15 Modules with a total of 8 CP720 Micros �� - �T �� © — — © m ®\\ _ .—. ® 1 o �� ©PV PV PV PV "' Module Module Module Module / Gonductors=#6AWG Ground #6AWG Modules grounded per Conductors=#6AWG Neurtal # 10AWG 690.43(C) with listed Ground #6AWG Distance 3' __ Sunmodo rail clips Neurtal #10AWG Distance 3' Voltage Drop Calculation and wire size all THHN copper: PV Module Ratings Inverters trunk cord =.400 Inverter Specs: Manufacture: REC Inverters to Combiner Box 10 awg =1.393% Manufacture: Chilicon Model #: REC320NP Module: CP720 Combiner Box to AC Disco 6 awg =.052% Open-Circuit Voltage: 40.3V Max Output Current: 2.4A AC Disco to panel 6 awg =.052% Operation Voltage: 34.2V Nominal Output Volts: 240V Total AC Voltage Drop =1.897% Max String Voltage: 1000V Output Frequency: 59.3hZ-60.5hZ Operating Current: 9.37A Output Volt Range: 211V-264V AC Point of Interconnection Job: Shukla Short-Circuit Current: 10.22A (NEC 690.54): Max Series Fuse: 20A Rated AC output: 40.8A Address: 16794 SW Snowdale St. Maximum Power(STC): 320W Total number of Modules: 33 (#of invertersX2.4A) Tigard, OR 97223 VOC Temp Coeff: -.27%C System Size: 10.56 kW Nominal AC Voltage: 240V IV a t i o rm a 1 s o Ia