Loading...
Report (5) /I1Ec2.0 -rxa / 12325-S0 ,�Afi►IFe/ 5/` RECEIVED APR 18 2019 DAIKIN CIN OF TIGARD BUILDING DIVISION SUBMITTAL DATA for MFIA Woodward Elementary - TB Prepared for: Apollo Mechanical Prepared by: Tyson McGraw Air Reps, LLC tysonm@airreps.com 503-517-9129 Job Number: WTZ8Z4 Page Prepared Date: 3/18/2019 Job Name: MFIA Woodward Elementary-TB 2 of 28 www.DaikinApplied.com Table of Contents Technical Data Sheet for RTU-1 4 Fan Curve-Exhaust for RTU-1 8 Fan Curve-Supply for RTU-1 9 Drawings(1)for RTU-1 10 Drawings(2)for RTU-1 11 Drawings(3)for RTU-1 12 Base Channel Cross Section 3 to 15_Drawing for RTU 13 Cabinet AB Sensor Locations_Drawing for RTU-1 14 Rebel 113126601_Drawing for RTU-1 15 Rebel 910111672_Drawing for RTU-1 16 Segofoperation Doc D_Drawing for RTU-1 17 Seg0fOperation Doc K_Drawing for RTU-1 19 Specification for RTU-1 20 Job Number: WTZ8Z4 Page Prepared Date: 3/18/2019 Job Name: MFIA Woodward Elementary-TB 3 of 28 www.DaikinApplied.com Technical Data Sheet for RTU-1 Job Information Technical Data Sheet Job Name MFIA Woodward Elementary-TB Date 3/18/2019 Submitted By Tyson McGraw Software Version 07.31 Unit Tag RTU-1 Unit Overview Model Number Voltage Design Cooling AHRI 210 Standard Efficiency ASHRAE 90.1 V/Hz/Phase Capacity EER SEER Btu/hr DPS005A 208/60/3 59149 12.8 18.2 ASHRAE 90.1-2016 compliant Unit Model Number: DPSOO5A Model Type: Cooling Heat Type: Gas Energy Recovery: None Application: Variable Volume, Duct SP Control Controls: Microtech III Outside Air: 0-100% Economizer with Drybulb Control Altitude: 0 ft Approval cETLus Physical Dimensions and Weight Length Height Width Weight 67.0 in 40.8 in 87.0 in 1487 lb Corner Weights Ll L2 L3 L4 281 lb 263 lb 456 lb 487 lb Construction Exterior Insulation and Liners Air Opening Location Return Supply Painted Galvanized Steel 1" Injected Foam, R-7, Bottom Bottom Galvanized Steel Liner Electrical Unit FLA MCA MROPD SCCR 27.9 A 30.9 A 40 A 5 kAIC Use only copper supply wires with ampacity based on 75° C conductor rating. Connections to Note: terminals must be made with copper lugs and copper wire. Return/Outside/Exhaust Air Outside Air Option Type Damper Pressure Drop Exhaust Air Type 0-100%Econ with Dry Bulb Control 0.05 inH,o Powered, Modulating with Building Pressure Control Job Number: WTZ8Z4 Page Prepared Date: 3/18/2019 Job Name: MFIA Woodward Elementary-TB 4 of 28 www.DaikinApplied.com Technical Data Sheet for RTU-1 Exhaust Fan Type Drive Type Wheel Diameter SWSI AF Direct Drive 12 in Motor (Qty)Horsepower Type Efficiency Full Load Current(Each) (1) 1.3 HP ECM Premium 3.1 A Performance Air Flow External Static Pressure Fan Speed Brake Horsepower CFM inH2O RPM HP 2000 0.50 2131 0.47 Filter Section Physical Type Quantity/Size Face Area Face Velocity Air Pressure Drop Combo 2"/4" rack with 2" MERV8 4/16 in x 16 in x 2 in 7.1 ft' 280.3ft/min 0.12 DX Cooling Coil Physical Coil Type Refrigerant Type Fins per Inch Rows Face Area Face Velocity Air Pressure Drain Pan drop Material Cu Tube/Al Stainless Fin R410A 14 4 6.0 ft2 329.5 ft/min 0.30 inH2O Steel Cooling Performance Capacity Indoor Air Temperature Ambient air Total Sensible Moisture Entering Leaving Temperature Btu/hr Btu/hr Removal Dry Bulb Wet Bulb Dry Bulb Wet Bulb Dewpoint °F lb/h °F °F °F °F °F 59149 56151 2.3 80.0 64.0 54.2 54.0 53.8 95.0 Condensate Connection Size: 3/4 in. Male NPT Fan Section Fan Type Fan Wheel Diameter Fan Isolation SWSI AF 16 in None Performance Airflow Total Static Pressure Fan Speed Brake Horsepower Altitude 1990 CFM 2.5 inH,0 2001 rpm 1.46 HP 0 ft Motor Drive Type Horsepower Efficiency FLA Type ECM Motor 4.0 Premium 8.8A Direct Drive Job Number: WTZ8Z4 Page Prepared Date: 3/18/2019 Job Name: MFIA Woodward Elementary-TB 5 of 28 www.DaikinApplied.com Technical Data Sheet for RTU-1 Gas Heat Section Physical Airflow Max Allowable Burner Size Connection (Qty)Size Heat Exchanger Material Temp Rise 1990 CFM 60.0°F 120 MBH (1)0.5 in. Female NPT Stainless Steel Performance Capacity Air Temperature Dry Bulb Air Pressure Drop Gas Pressure Modulation Btu/hr Entering Leaving inH2O Minimum Maximum "F °F inHzO inF60 96000 60.0 104.5 0.32 7 14 Modulating 5:1 Turndown Unit Discharge Conditions AirTemperature Motor Heat Moisture Removal Unit Leaving Dry Bulb Unit Leaving Wet Bulb Unit Leaving Dewpoint Btu/hr Ib/h `F °F 'F 4738 2.3 56.4 54.7 53.8 Condensing Section Compressor Type Quantity Refrigerant Charge Total Power Capacity Control Compressor Isolation lb Inverter Scroll 1 15.3 3.49 kw Mod Control with Rubber in Shear Inverter Compressors Compressor Amps: Compressor 1 11.9 A Compressor Options: Suction and Discharge Isolation Valves Condenser Coil Type Fins per Inch Fin Material Copper Tube 23 Aluminum Condenser Fan Motors Number of Motors Full Load Current(Total) 1 2.0 A AHRI 210 Certified Data at AHRI 210 Standard Conditions Nxss,4"W �., '.3f.;- w Net Capacity EER SEER ASHRAE90.1 57600 Btu/hr 12.8 18.2 ASHRAE 90.1-2016 compliant Internal Pressure Drop Calculation External Static Pressure: 1.25 inH.O Filter: 0.12 inH2O Dirty Filter: 0.50 inH2O Outside Air: 0.05 inH20 DX Coil: 0.30 inH2O Gas Heat: 0.32 inH2O Total Static Pressure: 2.55 inH5O Sound Sound Power Oh) Frequency 63 Hz 125 Hz 250 Hz 500 Hz 1 kHz 2 kHz 4 kHz 8 kHz Inlet 78 76 84 79 81 75 70 64 Discharge 78 79 87 84 87 81 78 72 Radiated 82 82 78 75 73 68 61 54 Job Number: WTZ8Z4 Page Prepared Date: 3/18/2019 Job Name: MFIA Woodward Elementary-TB 6 of 28 www.DaikinApplied.com Technical Data Sheet for RTU-1 Options Unit Smoke Detectors: Return Air Smoke Detector Ventilation Controls: CO2 Sensor-Duct Mounted Electrical Field Connection: Non-Fused Disconnect Switch Powered Receptacle: Unit powered 115V GFI outlet Power Options: Phase Failure Monitor Controls Communication Card: BACnet/MSTP card, Factory installed Factory Installed Sensors Leaving Coil/Entering Fan Temperature Sensor Duct High Limit Switch Duct Static Pressure Sensor BACnet/MSTP Card Return Air Temperature Sensor Discharge Air Temperature sensor—Wired in unit,mounted in supply duct Outside Air Temperature Sensor Dirty Filter On/Off Switch Supply Fan Air Proving Via Modbus Building Static Pressure Sensor Warranty Parts: Standard One Year Compressor: Standard One Year Gas Heat Exchanger: Extended Nine Year,Ten Year Total AHRI Certification A CERTIFIED. All equipment is rated and certified in accordance with AHRI 360. Notes Accessories Mandatory Part Number Description 910111672 CO2,Telaire, Duct Sensor Job Number: WTZ8Z4 Page Prepared Date: 3/18/2019 Job Name: MFIA Woodward Elementary-TB 7 of 28 www.DaikinApplied.com Fan Curve - Exhaust for RTU-1 Daikin Fan Selection 4.0 — 2580 RPM /\ V , - _� 2RPM 03.0 •�� ` is RP NIIN V i 20001WM 4? N 2.0 1800 RPM ai --N.„ \ a 1600 RPM11 v CO 1400 RPM el 1 0 1200 RP 000 R' '''.11‘sie s,\..,4.. ., Ic.'',„. \\AHc) \ \ IMF!Aimmoisib.. 0.0 i I 0.0 1000.0 1T F20000.0`�M� 3000.0 4000.0 1 z.0 SW51- Nlen m-EXha�ust F�11'afSYdndard Conditions Base lag it I U-1 Date M_ar-1 ti-2019 qbb N me MFL WoodwardC FM Elementary-TB Time 08 PM AirVolume 2000 Fan Speed 2131 RPM Total Static 0.5 inWg Max Speed 2580 RPM Brake Horsepower 0.47 HP Efficiency 33 r DA/K#N Job Number: WTZ8Z4 Page Prepared Date: 3/18/2019 Job Name: MFIA Woodward Elementary-TB 8 of 28 www.DaikinApplied.com Fan Curve - Supply for RTU-1 Daikin Fan Selection -2550 RPM - - N c - +i RPM .- -11 air4111\ ' i 3.0 — i ARP, . y N 80D RP' d 2.0 lsoo`RPM.. -r... ;7.J -1400,•PM-------- U� 1.0 -1200 RPM`----A-_.. --- p 'O - 1000 RPM .....:..':., -800RPM ! ' \.. iii 0.0 1000.0 2000.0 3000.0 4000.0 5000.0 6000.0 t�{t�LUU� 16 U svYS1-Plen1Ai6 /jyF 8rd Condition �s Iran MFw1 dward�e mentary-TB Ime llOt9 eN1 ot o tic G;JAI n eed t) VM rat oresie ower9 IC 4B �D Qe.' unc1 PQwe� 1' ` z 1 z 5 1 R Itz ac iatec� ounower _ �v 3 Dal% N Job Number: WTZ8Z4 Page Prepared Date: 3/18/2019 Job Name: MFIA Woodward Elementary-TB 9 of 28 www.DaikinApplied.com I o` o` 0 s c —1 d v c 3 3 0 ro cr o0 alu+ Fa K * 0 TI D N -I —I o' o A C o N n t c,I. 40.8 l m m , a , toDA.INLET - BOjTOM EOOE�.� t n, G -1 8 .0 "--0. .A (2 .e rFry Jags onan. q O . NEo oNT H7 2a NT N 00 67.0 84.5 v Notes: v (1)Recommended location for optional field cut side power connection. m (2)Horizontal gas connection only.Gas pipe routing within the rooturb is not available. z co a v ID m 0 o p Product Drawing Unit Tag: RTU-1 Sales Office:Air Reps,LLC(Oregon) rDAIK/N o u' N Product: Project Name:META Woodward Elementary- Sales Engineer: a W --_- - - - - -- -- - - --- - 13600 Industrial Park Blvd.Minneapolis,MN 55441 is-, Model:DPS005A Mar.18,2019 Ver/Rev: Sheet 1 of 1 Scale:NTS Tolerance:+/-0,25" Dwg Units:in[mm] www.DaikinApplied.com Software Version:07.31 n O o No change to this drawingmaybe made unless approved in writingbyDaikin Applied. Purchaser must determine that the equipment is fit and sufficient for the specifications. ' � � g PP PPjobP Drawings(2) for RTU-1 5.0 27.9--- T CONDENSER GAS HEAT HOOD 87.0 89 —` -POWER ENTRY 52.9 o i 39.7 0 26.0 / `, li.1 ) 11(.2 5.3 5.0 —8.9-- DRAIN 32.4 HEIGHT 6.6 58.6 62.5 67.0 94.5 PLAN VIEW-OPENINGS &OVERALL Product Drawing Unit Tag: RTU-1 ""DA/K/N Product: Project Name:MFIA Woodward Elementary 13600 Industrial Park Blvd.Minneapolis,MN 55441 Model: DPSOO5A Sales Office:Air Reps,LLC(Oregon) www.DaikinApplied.com Software Version:07.31 Sales Engineer Mar.18,2019 Ver/Rev: Sheet 1 of 1 Scale:NTS Tolerance:+/-0.25" Dwg Units:in[mm] No change to this drawing may be made unless approved in writing by Daikin Applied. Purchaser must determine that the equipment is fit and sufficient for the job specifications. Job Number: WTZ8Z4 Page Prepared Date: 3/18/2019 Job Name: MFIA Woodward Elementary-TB 11 of 28 www.DaikinApplied.com o` o` a c zi c 3 3 0 �. Corner Weight L4-487 lb Corner Weight L3-456 lb oN ro 0 D- W Condenser -t o o k.. Q PWnO ['['UMWsw pr ose Hut 60.0 a Q m ro 60.0 r: 2 O LL Z O :6 S 8 C LL cal ,-+ 0 v w Corner Weight L2-263 lb Corner Weight L1 -281 lb 60.0 NJ D1 —sr Al oc (D CO 32.4 PLAN VIEW-CG,CORNER WEIGHTS,SERVICE CLEARANCE Notes: D (1)Center of Gravity Height=20.3 m (2)Total Weight=1487 lb ro a v sli ro cu ro cu o Product Drawing Unit Tag: RTU-1 Sales Office:Air Reps,LLC(Oregon) W rDA/K/N . N Product: Project Name:MFIA Woodward Elementary- Sales Engineer: a 00 13500 Industrial Park Blvd.Minneapolis,MN 55441 N Model:DPS005A Mar.18,2019 Ver/Rev: Sheet:1 of 1 Scale:NTS Tolerance:+/-0.25" Dwg Units:in[mm] www.DaikinApplied.com Software Version:07.31 o Q No change to this drawingmaybe made unless approved in writingbyDaikin Applied. Purchaser must determine that the equipment is fit and sufficient for the job specifications. � � g PP PPP Base Channel Cross Section 3 to 15_Drawing for RTU-1 /DECK PANEL • • • I 5.75 • • 4.50 • • BASE CHANNEL 14.00 OR • 24.00 • ------------� CURB 2.50 -� Product Drawing Unit Tag: RTU-1 V DAIKIJIH Product: Project Name: MFIA Woodward Elementary • 13600 Industrial Park Blvd.Minneapolis,MN 55441 Model: DP5005A Sales Office:Air Reps,LLC(Oregon) www.oaikinApplled.com Software Version:07.31 Sales Engineer: Mar.18,2019 Ver/Rev: Sheet 1 of 1 Scale:NTS Tolerance:i/-0.25" Dwg Units:in(mm] No change to this drawing may be made unless approved in writing by Daikin Applied. Purchaser must determine that the equipment is fit and sufficient for the job specifications. Job Number: WTZ8Z4 Page Prepared Date: 3/18/2019 Job Name: MFIA Woodward Elementary-TB 13 of 28 www.DaikinApplied.com 13-QO T -c4 - 4 4-)..0 Cl.)d. STANDARD C_ON_STRUC770N DETAILS (AIE11EI131EOArc TOLEENCEO PER Ansi TI.5M,.° REVISIONS DUCT FLEX CONNECTIONS PROVIDED BY OTHERS REV ECOB DESCRIPTION DATE APPROVED 2X4 WOOD NAILER 1 INRIALDRAWING 1125/19 SRP SPRING ACCESS DOORS ARE GASKETED AND SCREWED ON GASKET MATERIAL PROVIDED FOR THE TOP FROM DRAWING PERIMETER(INCLUDING BRACES) OVERALL 23-1/4" 26-1/4" 30.1/4" 36-1/4" SUPPLY HEIGHT SPRING PACKS MAY REQUIRE FIELD ADJUSTMENT BASE CURB HEIGHT 11 14 18 24 (BY OTHERS) BASE MATERIAL GA 12 12 12 12 14GA BOXED TOP FRAME FULLY WELDED GALVANIZED(G-90)CONSTRUCTION CURB WEIGHT 370 - 395 425 475 WEATHER SEAL BETWEEN UPPER&LOWER RETURN 18GA DUCT BRACES SECTIONS PROVIDED(BULB SEAL) ANCHORING CURB TO ROOF FOR STEEL,CONCRETE t OR WOOD,SEE DETAIL DRAWING"ROOF ANCHOR" FORM NO.SEISMIC-ATTACHMENTS � } 7/ 11 aa" SUPPLY 17 3/4" ,\ I - I I 12GA CURB BASE ��\ / /` / �� 2 14GA BASE SUPPORTS AT \ II/ 7 EACH SPRING LOCATION I— (INSULATED) W CQ N. /11 5/8"I-- UNIT BASE RAIL - 30 5/8" S11,1 2"�- 61 1/2' �� -- 48 7/18" 58"BASE CURB 1.0, -1 i SCREW THRU UNIT BASE 44 15/18'BASE CURB I.D. 1„ RAIL AND CURB PER -- 21/2" STAMPED REPORT � 5"f t t 2 3/4" -- BASE CURB+121/4 (38"MAX WITH PITCH) I I \--' CURB _�'- BASE CURB J DETAILG SCALE 1'4 HEIGHT THIS TINAMAND 6 THE INFORMATION CONTAINED C1.BE WEIGHT I.211 APPROVALS MTR Tnc CURB DESIGNED TO MEET SEISMIC&WIND LOAD REQUIREMENTS FOR 2012 THEREIN IS THE CONFIDENTIAL.FNONINETARY .R..e INFORMATION NOT BUSEDO CRYSTAL PRODUCEION INC„ 369.51 6piskaz C7-0OXX-7720 AND 201518C/ASCE 7-10,AND 2014 FLORIDA BUILDING CODE N ORMATI OUEDOS REPRODUCED WIND DESIGN:MAX BUILDING HEIGHT 60FT,Kzt FACTOR=1,00 MAX SEISMIC ISOLATION CURB WRHWTTNEAPPaOVAt OF CRYSTAL DISTRIBUTION.INC. WITHOUNT INEBERVED 2012 IBC/ASCE 7-10:MAX 185 MPH ULTIMATE DESIGN WIND SPEED,RISK "• Frltlar.January 28.20189:59:54 AAA CURB SILOMI IS COI STANDARD _ CATEGORY II,III,OR IV BUILDING,EXPOSURE C OONFIDURMTIax DOI RESERVES THE NIHT TO ,_,„ „ati?" 17640 TYLER OT NW C7AOXX 7720 mt.*0xa. SEISMIC:Ss=2.00 MAX,IMPORTANCE FACTORIp=1.5,SOS=1.33 GRANGE LAVOITYNTHOUT NOTIFICATION.A. W� CD7ELK RIVER,MN 66880 '� QIRBIS NEEDED IN A DIFFERENT I/ll �°„ CONFIGURATION COI MUST E NOTIFIED PRIOR "^'_" (7aS14'91-T/90 TO PUnTINGMORDER. ai:"n .6 783)351-7861 watt 1:20, elm. 1 OF B C:Users\spickarlDOcuments\SeismickREVISED STOCK CONFORMING CURBS17000 SERIES\C7-O0XX-77201 STEEL ATTACHMENT CONCRETE ATTACHMENT n CURE ASSEMBLY 1 1/2"0 A307 BOLTS OR EQUIVALENT CURB ASSEMBLY EQUALLY SPACED ON CURB EASE FLANGE ATTACHED TO STRUCTURAL STEEL BELOW SHEATHING DECK AT EACH CONNECTION POINT WHERE OCCURS 51B"0 X 31/2" EMPSON STRONG BOLT 2 METAL DECK EQUALLY SPACED ON CURB BASE FLANGE. SPECIAL INSPECTION REQUIRED ea 1110 (ESR REPORT 3037) ._-� 'CONCRETE SLAB: 1'c=4000 psi MINIMUM NORMAL WEIGHT CONCRETE 8" r MINIMUM THICKNESS.12"MINIMUM EDGE DISTANCE L oprre� ESTAM PER USE STEEL ATTAC HMETAL DECK: STRUCURAL STEEL SUPPORT STAMPED FRAMINGEBELOW DECK T CONNECTION TO STEEL BY OTHERS 'ROOF �� CALCULATION COSCRBTE �'/,4,A WOOD ATTACHMENT CURB DESIGNED TO MEET SEISMIC&WIND LOAD REQUIREMENTS FOR 2012&2015 IBC/ASCE 7-10 WIND DESIGN:MAX BUILDING HEIGHT 60FT,Kit FACTOR=1.00 MAX 201Z IBC/ASCE 7-10:MAX 185 MPH ULTIMATE DESIGN WIND SPEED, RISK CATEGORY II,III,OR IV BUILDING,EXPOSURE C SEISMIC:Ss=2.00 MAX,IMPORTANCE FACTOR Ip=1.5 CURB ASSEMBLY 114"SDS WOOD SCREWS OR EQUIVALENT EQUALLY SPACED ON CURB BASE FLANGE 3 1/2" IN , EMBED 1M INFORMATI0N0TNEIHTLDISTD$BTIOR INC.. •,�. k,, mien[wc: THEREIN IS THE APPROVAL OF PROPRIETARY DISTRIBUTION xn� IHERIN ISHEFCIIFWENIAL PROTRIE .. '` SD CkOf 7/2412017 MAT No1 BE USED of REPRODUCED SEISMIC-CURB-ATTACHMENTS ALL NIGHTS THE R OF CRYSLN.D0TR011TRIN.INC. ALL RIGHTS RESERVED DIMENSIONS ARE AS FOLLOWS:IP01n 5FAC HAT) billiNd 00.A. APPROXIMATE At'=_� Contact us@ CURB WEBM ILH4I �- _ f f� *t am www.edieurhs.eam "�� or _4 , 1.BSF13/-7Oh1 .cue 1:25 I wen 1 of 2 / `�`` VAK Construction Engineering Services, LLC VA J 1 8285 SWBeaverton NimbusOregon 970 Avenue,08 Suite 104 , 503.718.5999 tel 503.718.5980 fax 4 aweidmanavakengineerinq.com TO: Steve Pickar, CDI Curbs Job # 18-001T FROM: Aaron Weidman EIT., VAK Engineering PROJECT: Stock Isolation Curbs C7-00XX-7720, Q1029509, 250084 DATE: 12/11/2018 As requested we have designed a fastening scheme for the 7720 units and their corresponding sheet metal curb. No evaluation of the roof or building structure was performed. The curb was evaluated using worst case seismic and wind loads from California and Florida. • Seismic Design • Wind Design: o SDS = 1.33 o Risk Category: II, III or IV o Max Unit Weight: 2000 lbs o Exposure Class C o Rp= 2 o Mean roof height: 60ft. o Ap = 2.5 o Wind Speed: 185 MPH Loads experienced by each curb and unit were calculated. The loads were used to design the unit to curb and curb to roof connections. The loads were also used to evaluate if the curb is adequate carry the unit and restrain the whole assembly to the roof structure. The unit to curb connection is made with #14 TEK screws passing through the lower lip of the curb and into the upper lip/flange of the curb. CalDyn JQ model isolators are used to isolate the forces generated by the unit into stiffened sections of the curb. The adequate CalDyn isolator was selected and the adequacy of the curb stiffener section was evaluated. This analysis was performed for a maximum unit weight of 2000 lbs, thus the total weight of the main unit plus any additions is to be equal to or less than 2000 lbs. If the unit weight is higher than this, further calculations will need to be performed. The unit shall be held onto the curb using (13) #14 TEK screws along each long edge of the curb section and (9) along each short edge for a total of (44). This curb requires Caldyn Model JQA isolators or better at all isolation support locations (12 total). A 14 gauge 1.5x6 channel supports the area immediately under each isolator. All channel supports were found to be adequate to resists compression failure and buckling due to isolator loads. All curb flanges were found to be adequate in bearing and bending. The anchorage to the roof was designed using CDI details from the drawing titled "SEISMIC-CURB- ATTACHMENTS" dated 7/24/2017 by spickar. The bearing of the bolts on the curb flange was evaluated considering the 12-gauge steel and .25" to .625" diameter bolts. All fasteners on the flange of the curb must be installed no more than 0.5" away from the inside edge of the flange. Screws should first be installed one on either side of each isolation support with the remainder spaced evenly. For a steel roof connection (6) 1/2" 0 A307 bolts or equivalent are required along each long edge of the curb Filename: 18-001 T LTR01 1 26 2018 Page 1 of 2 VAK MEMO 12/11/2018 and (2) along each short edge of the curb for a total of (16). For a wood roof connection 1/4" 0 SDS wood screws or equivalent are required, (15) along each long edge of the curb and (13) along each short edge for a total of (56) screws. For a concrete roof connection 5/8"O Simpson Strong Bolts are to be used (6) are required along each long edge of the curb and (2) along each short edge for a total of(16) bolts. Please feel free to contact us should anything further be required or if questions arise. Regards, Aaron Weidman, E.I.T. /i .16 ! ` 1 -- M , QieiFES aq� \ 1� F WASl Flt- p. (ft O .�\ Li.) e -, ,/f c- m °31 ��',;:i rL l+ w` 41 1 SlONALFS.43 4" 3 37fz II zv ii(.60 l I( to() `tee``, �1. SAME Ns�ryF�i Ep PflOff •.til. �`�c.. G11rE�/ate c• . 845 .`z w ti�g4f/N J. N��� y11,110 � r�fk f EXPIRES:0.1(s)t 1 Filename: 18-001 T LTRO 1 1 26 2018 Page 2 of 2 Cabinet AB Sensor Locations_Drawing for RTU-1 Rebel 3-15 Tons Factory Installed Sensor Locations' '/,>) 744 11°.°1.11:41.1 SENSOR DESCRIPTION LABEL Return Air Temp Sensor A Discharge Air Temperature sensor—Wired in unit, B mounted in supply duct Outside Air Temp Sensor C Return air Enthalpy Sensor D Outside Air Enthalpy Sensor E Dirty Filter On/Off Switch F Supply Fan Air Proving Via Modbus G Duct High Limit Switch H Duct Static Pressure Sensor I Building static pressure sensor J Leaving Coil/Entering Fan Temp Sensor K BACnet/IP card LON card BAS BACnet/MSTP card Comm. Daikin Intelligent systems Card DIII Gateway Card(VRV Communication) Condensate Overflow Switch L Ebtron Airflow Station M Supply Leaving Wheel Temp Sensor N Exhaust Leaving Wheel Temp Sensor 0 Return Air Relative Humidity Sensor P Energy Wheel VFD q 1) Sensors provided are based on unit selection. Refer to unit specific technical data sheet for selection specific sensor list. Product Drawing Unit Tag: RTU-1 prirIAIKIN Product: Project Name:MFIA Woodward Elementary 13600 Industrial Park Blvd.Minneapolis,MN 55441 Model:DPS005A Sales Office:Air Reps,LLC(Oregon) www.DaikinA elied.com Software Version:07.31 Sales Engineer: Mar.18,2019 Ver/Rev: Sheet 1 of 1 Scale:NTS Tolerance:N-0.25" Dwg Units:in[mml No change to this drawing may be made unless approved in writing by Daikin Applied. Purchaser must determine that the equipment is fit and sufficient for the job specifications. Job Number: WTZ8Z4 Page Prepared Date: 3/18/2019 Job Name: MFIA Woodward Elementary-TB 14 of 28 www.DaikinApplied.com Rebel 113126601_Drawing for RTU-1 Overview Specifications Smoke detectors are use to detect Daikin Pan Number 113126601 smoke in the return air stream, 11110 Supply Voltage 24 VAC:6 35 mA standby.74 mA alarm; supply air stream,or both. A set of ?15°C: 125 n AmA Bsnnanddby.32 mA a m. normaly closed contact will open in 230 VAC 6 12 mA standby.16 mA alarm the presence of smoke. This can be w Frequency 6060 Hz used to shut down the RTU by either Air Velocity 0-2000rpm(0-10.2 mps) cutting power across the terminal of Radioactive Element For HS-100-N only Americium 241,0.9 pCi a thermostat controlled RTU or as a Relay Output Alami 1-SPDT 10A.115 VAC.resistive: signal to DDC controlled RTU. ret W1-seNO,2A Trouble 1-SPST-NC,10A,115 VAC. Wiring Terminations Sofid or stranded.12 to 22 AWG terminals Features Operating Humidity 0%to65%RH nen-condensing • Universal voltage:24 VAC,24 VDC,115 VAC,or 230 VAC Operating Temperature HS-100-N 32'to 155°F(0°to 70°C) • Visual indication of power and alarm status Enclosure Rating White plastic,NEMA 1 • Two alarm contacts and one trouble contact Dimension 6'(Diu)'4.01H)(15.2.10.2 cm) • Interchangeable"plug-in"photoelectric or ionization heads • Compatible with building automation and fire alarm systems • Dust filtering included in detector head • Interconnect up to 30 detectors for common function Product Drawing Unit Tag: RTU-1 ®DQIKIN Product: Project Name: MFIA Woodward Elementary 13600 Industrial Park Blvd.Minneapolis,MN 55441 Model:DP5005A Sales Office:Air Reps,LLC(Oregon) www.DaikinApelied.com Software Version:07.31 Sales Engineer: Mar.18,2019 Ver/Rev: Sheet 1 of 1 Scale:NTS I Tolerance:./-0.25" Dwg Units:in[mm] No change to this drawing may be made unless approved in writing by Daikin Applied. Purchaser must determine that the equipment is fit and sufficient for the job specifications. Job Number: WTZ8Z4 Page Prepared Date: 3/18/2019 Job Name: MFIA Woodward Elementary-TB 15 of 28 www.DaikinApplied.com Introduction Specifications m cr The CO2 sensor will communicate a signal to Daikin Part Number 910111672 tD 1-1 re the MicroTeche Ill unit controller for applications Power Consumption Typical 0.7 W at nominal voltage of 24V AC RMS 0 that require demand control ventilation damper Temperature Dependence 0.2%FS per°C(ominal per°F) N 1 positioning.This device allows the Microtech Ill unit 32°F to 122•F(a°c to So°c) m �+ Operating Conditions V D controller to modulate the outdoor air damper to o to 95%RH,non-condensing N * a maintain a PPM CO2 set point. 2 minutes(operational) l O co,Warmup Time 10 minutes(maximum accuracy) o When the MicroTech Ill is performing Demand 01 0g Control Ventilation(DCV)on a Constant Volume unit Signal Update Every 5 seconds g a (CAV),the outside air damper modulates between Analog output o iavoc �' rn the DCV limit and vent limit to maintain the CO2 PPM co,Range o 200o ppm E, 3 set point. z When the MicroTech Ill is performing DCV on a --I 2 Variable Air Volume(VAV)unit,the outside air C ILdamper modulates between the DCV limit and —1 vent limit corresponding to the supply fan airflow to maintain the CO2 PPM setpoint. 1-- cr. O 5) mm(In) —n In 01.4 r3201 271 (1077 N N Co MIIIIIIIIIIII 24V• 24V+ I 012 SH6Nr tElaYrYS 1 ,' e ���rff.Rt1rr�icpiyy, NOTE: AC y1' NOTE: 24 VAC connections r should be on the 9 I •�� MicroTech controller 1166 (43!) TB2 J. Signal Fl �' i`+71� power source.Do cu -7.(7.1 , - - - - �_ �r,EI not use external n 1241 �� _ power supply for the Common •isms sensor. rt � Ji gIplPspp CI I of Q — I = _ * J o, 1z1c — - — - f b I 5 ;0 W Product Drawing Unit Tag: RTU-1 Sales Office:Air Reps,LLC(Oregon) �DA/K/N D. - Product: Project Name:MFIA Woodward Elementary- Sales Engineer: 13e00 Industrial Park Blvd.Minneapolis,MN 55441 m ID- N Model:DPS005A Mar.18,2019 Ver/Rev: Sheet:1 of 1 Scale:NTS Tolerance:+/-0.25" Dwg Units:In Imml www.DaikinApplied.com Software Version:07.31 O 0 • No change to this drawing may be made unless approved in writing by Daikin Applied. Purchaser must determine that the equipment is fit and sufficient for the job specifications. SegOfOperation Doc D_Drawing for RTU-1 Sequence of Operation Specifications: o UNIT CONTROLS: • Building Automation System(BAS) interface:The factory unit controller will interface with BACnet MSTP, IP and LON BAS systems (requires optional communication card). • Head Pressure Control:The condenser head pressure will be monitored by the unit controller to maintain head pressure and the compressor operating envelope at all times to avoid high pressure trips on high load days. Condenser fans with ECM motors shall be provided as well as factory sensors to provide this protection. • Compressor Envelope Control: The unit controller will continually monitor the suction and discharge pressure and temperature conditions during compressor operation. The unit will modulate the compressor, condenser head pressure,and electronic expansion valve to maintain a safe compressor operating conditions to add reliability,and limit unit shut down during fringe operating conditions. o CHANGE OVER SETPOINTS: The unit change over source temperature is the variable, Outdoor air temperature (OAT), Return air temperature(RAT),or space temperature(ST),that drives the change of unit states. The unit state will change from cooling,fan only or heating based on the changeover heating or cooling setpoints. o SUPPLY FAN:The RTU will be factory supplied with a direct drive supply fan. • VAV Duct Pressure: The supply fan will operate continuously. The unit will modulate the supply fan as required to maintain the duct pressure set point. o OUTSIDE AIR DAMPER CONTROL: • Proportional damper reset:The unit controller will proportionally modulate the outside air dampers open and closed as the supply fan speed changes to provide a constant volume of fresh outside air. • Outdoor air monitor:The unit controller will modulate the outside air damper as required to maintain the outside air cfm setpoint as measured by the factory provided flow station (Requires Optional OA Monitor). • DCV:A space or duct mounted CO2 sensor will supply a PPM reading to the unit controller. The unit controller will open the OA damper to provide more ventilation air as required by the CO2 PPM reading(Requires Optional CO2 Sensor) • External Reset:An external 0-10 VDC or 4-20 mA signal can be wired to the unit controller to control the OA damper position by a third party. o COOLING: • Discharge Air Control: In the cooling mode,the unit capacity will modulate the variable speed compressor to maintain the unit cooling discharge air set point. The cooling DAT set point will be adjustable at the unit controller. Unit capacity will be modulated by the variable speed compressor operation. • Cooling DAT reset:The cooling DAT setpoint may be reset by the space temp, return temp,OAT or external Voltage/mA signals. A linear relationship between the DAT and the reset variable will be Job Number: WTZ8Z4 Page Prepared Date: 3/18/2019 Job Name: MFIA Woodward Elementary-TB 17 of 28 www.DaikinApplied.com SegOfOperation Doc D_Drawing for RTU-1 created for the minimum and maximum DAT setpoints.As the reset variable changes the DAT will adjust according to the relationship. o ECONOMIZER: A comparative dry bulb(standard option)or comparative enthalpy(selectable option)shall be engaged whenever the outdoor enthalpy or dry bulb is less than the return air enthalpy or dry bulb to utilize outside air for cooling. Outside air and return air dampers shall modulate to maintain supply air temperature set point. o EXHAUST FAN CONTROL: If the optional exhaust fans are provided they will be direct drive electrically commutated motor(s)(ECM). If powered exhaust is not provided barometric relief dampers are standard. Powered exhaust control options are as follows: • Building pressure Control: A differential pressure transducer shall compare the indoor building pressure to ambient atmospheric pressure. The exhaust fan(s)shall modulate to maintain the building pressure set point. • Speed Control:The exhaust fan(s)will run at a constant speed. • Network Control: Exhaust fan speed is commanded from the building automation system. • Outdoor Air Damper Tracking: The exhaust fan(s)will activate based on the outside air damper position and will modulate between an adjustable minimum and maximum as the OA damper opens to provide relief. Job Number: WTZ8Z4 Page Prepared Date: 3/18/2019 Job Name: MFIA Woodward Elementary-TB 18 of 28 www.DaikinApplied.com Seg0fOperation Doc K_Drawing for RTU-1 Sequence of Operations GAS HEAT The unit is provided with staged or modulating gas heat. • Modulating Gas Heat:The modulating gas heat will be modulated by the unit controller to maintain the heating DAT set point. • Staged Gas Heat:The staged gas heat will increase or decrease stages based on the stage timer and whether the DAT is greater or less than the effective DAT setpoint. Heating DAT reset: The heating DAT setpoint may be reset by space, return,OAT, Network or external Voltage/mA signals. A linear relationship between the DAT and the reset variable will be created for the minimum and maximum DAT setpoints.As the reset variable changes the DAT will adjust according to the relationship. Job Number: WTZ8Z4 Page Prepared Date: 3/18/2019 Job Name: MFIA Woodward Elementary-TB 19 of 28 www.DaikinApplied.com Specification for RTU-1 PART 1: GENERAL 1.01 SECTION INCLUDES A. Packaged Rooftop air conditioners 1.02 REFERENCES A. AFBMA 9-Load Ratings and Fatigue Life for Ball Bearings. B. AMCA 99—Standards Handbook C. AMCA 210—Laboratory Methods of Testing Fans for Rating Purposes D. AMCA 500—Test Methods for Louver, Dampers, and Shutters. E. AHRI 340/360 -Unitary Large Equipment F. NEMA MG1—Motors and Generators G. National Electrical Code. H. NFPA 70—National Fire Protection Agency. I. SMACNA—HVAC Duct Construction Standards—Metal and Flexible. J. UL 900—Test Performance of Air Filter Units. 1.03 SUBMITTALS A. Shop Drawings: Indicate assembly, unit dimensions,weight loading, required clearances,construction details,field connection details,electrical characteristics and connection requirements. B. Product Data: 1. Provide literature that indicates dimensions,weights,capacities,ratings,fan performance, and electrical characteristics and connection requirements. 2. Provide computer generated fan curves with specified operating point clearly plotted. 3. Manufacturer's Installation Instructions. 1.04 OPERATION AND MAINTANENCE DATA A. Maintenance Data: Provide instructions for installation, maintenance and service 1.05 QUALIFICAITONS A. Manufacturer: Company specializing in manufacturing the Products specified in this section with minimum five years documented experience,who issues complete catalog data on total product. B. Startup must be done by trained personnel experienced with rooftop equipment. C. Do not operate units for any purpose,temporary or permanent, until ductwork is clean,filters and remote controls are in place, bearings lubricated, and manufacturers' installation instructions have been followed. 1.06 DELIVERY,STORAGE,AND HANDLING A. Deliver,store, protect and handle products to site. B. Accept products on site and inspect for damage. C. Store in clean dry place and protect from weather and construction traffic. Handle carefully to avoid damage to components,enclosures,and finish. PART 2: PRODUCTS 2.01 MANUFACTURERS A. Basis of Design: Daikin Applied 1. No equal exists. [Deducts for alternative equipment will be considered.] 2.02 GENERAL DESCRIPTION Job Number: WTZ8Z4 Page Prepared Date: 3/18/2019 Job Name: MFIA Woodward Elementary-TB 20 of 28 www.DaikinApplied.com Specification for RTU-1 A. Furnish as shown on plans, Daikin Applied Rebel Single zone Heating and Cooling Unit(s) model DPS. Unit performance and electrical characteristics shall be per the job schedule. B. Configuration: Fabricate as detailed on prints and drawings: 1. Return plenum /economizer section 2. Filter section 3. Cooling coil section 4. Supply fan section 5. Gas heating section. 6. Condensing unit section C.The complete unit shall be cETLus listed. D. The unit shall be ASHRAE 90.1-2016 compliant and labeled. E. Each unit shall be specifically designed for outdoor rooftop application and include a weatherproof cabinet. Each unit shall be completely factory assembled and shipped in one piece. Packaged units shall be shipped fully charged with R-410 Refrigerant and oil. F. The unit shall undergo a complete factory run test prior to shipment.The factory test shall include a refrigeration circuit run test,a unit control system operations checkout,a unit refrigerant leak test and a final unit inspection. G. All units shall have decals and tags to indicate caution areas and aid unit service. Unit nameplates shall be fixed to the main control panel door. Electrical wiring diagrams shall be attached to the control panels. Installation,operating and maintenance bulletins and start-up forms shall be supplied with each unit. H. Performance:All scheduled EER, IEER,capacities and face areas are minimum accepted values. All scheduled amps, kW, and HP are maximum accepted values that allow scheduled capacity to be met. I. Warranty:The manufacturer shall provide 12-month parts only warranty. Defective parts shall be repaired or replaced during the warranty period at no charge.The warranty period shall commence at startup or six months after shipment,whichever occurs first. 2.03 CABINET, CASING,AND FRAME A. Panel construction shall be double-wall construction for all panels. All floor panels shall have a solid galvanized steel inner liner on the air stream side of the unit to protect insulation during service and maintenance. Insulation shall be a minimum of 1"thick with an R-value of 7.0,and shall be 2 part injected foam. Panel design shall include no exposed insulation edges. Unit cabinet shall be designed to operate at total static pressures up to 5.0 inches w.g. B. Exterior surfaces shall be constructed of pre-painted galvanized steel for aesthetics and long term durability. Paint finish to include a base primer with a high quality, polyester resin topcoat of a neutral beige color. Finished panel surfaces to withstand a minimum 1000-hour salt spray test in accordance with ASTM B117 standard for salt spray resistance. C. Service doors shall be provided on the fan section,filter section,control panel section,and heating vestibule in order to provide user access to unit components. All service access doors shall be mounted on multiple,stainless steel hinges and shall be secured by a latch system. Removable service panels secured by multiple mechanical fasteners are not acceptable. D. The unit base shall overhang the roof curb for positive water runoff and shall seat on the roof curb gasket to provide a positive,weathertight seal. Lifting brackets shall be provided on the unit base to accept cable or chain hooks for rigging the equipment. 2.04 OUTDOOR/RETURN AIR SECTION A. Unit shall be provided with an outdoor air economizer section.The economizer section shall include outdoor, return,and exhaust air dampers.The economizer operation shall be fully integral to the mechanical cooling and allow up to 100%of mechanical cooling if needed to maintain the cooling discharge air temperature. The outdoor air hood shall be factory installed and constructed from galvanized steel finished with the same durable paint finish as the main unit.The hood shall include moisture eliminator filters to drain water away from the entering air stream. The outside and return air dampers shall be sized to handle 100%of the supply air volume.The dampers shall be Job Number: WTZ8Z4 Page Prepared Date: 3/18/2019 Job Name: MFIA Woodward Elementary-TB 21 of 28 www.DaikinApplied.com 1 Specification for RTU-1 parallel blade design. Damper blades shall be gasketed with side seals to provide an air leakage rate of 1.5 cfm/ square foot of damper area at 1"differential pressure in according with testing defined in AMCA 500. A barometric exhaust damper shall be provided to exhaust air out of the back of the unit. A bird screen shall be provided to prevent infiltration of rain and foreign materials. Exhaust damper blades shall be lined with vinyl gasketing on contact edges. Control of the dampers shall be by a factory installed direct coupled actuator. Damper actuator shall be of the modulating,spring return type.A comparative enthalpy control shall be provided to sense and compare enthalpy in both the outdoor and return air streams to determine if outdoor air is suitable for"free"cooling. If outdoor air is suitable for"free"cooling,the outdoor air dampers shall modulate in response to the unit's temperature control system. B. Provide a field installed Duct/Space mounted CO2 sensor. Outside air damper position will modulate between the Demand Control Ventilation Limit(minimum position setpoint)and the Ventilation Limit(maximum non-economizer position setpoint)to satisfy the space requirements. Damper position will be controlled to the greater of the two command signals,either minimum outside air flow or space IAQ(CO2). 2.05 EXHAUST FAN A. Exhaust fan shall be a single width,single inlet(SWSI)airfoil centrifugal fan.The fan wheel shall be Class II construction with aluminum fan blades that are continuously welded to the hub plate and end rim.The exhaust fan shall be a direct drive fan mounted to the motor shaft. Belts and sheaves are not acceptable due to the additional maintenance. B. The fan motor shall be a totally enclosed EC motor that is speed controlled by the rooftop unit controller. The motor shall include thermal overload protection and protect the motor in the case of excessive motor temperatures. The motor shall have phase failure protection and prevent the motor from operation in the event of a loss of phase. Motors shall be premium efficiency. C. The unit DDC controller shall provide building static pressure control.The unit controller shall provide proportional control of the exhaust fans from 25%to 100%of the supply air fan designed airflow to maintain the adjustable building pressure setpoint. The field shall mount the required sensing tubing from the building to the factory mounted building static pressure sensor. 2.06 FILTERS A. Unit shall be provided with a draw-through filter section.The filter rack shall be designed to accept a 2" prefilter and a 4"final filter. The unit design shall have a hinged access door for the filter section. The manufacturer shall ship the rooftop unit with 2" MERV 8 construction filters. The contractor shall furnish and install,at building occupancy,the final set of filters per the contract documents. 2.07 COOLING COIL A. The indoor coil section shall be installed in a draw through configuration, upstream of the supply air fan.The coil section shall be complete with a factory piped cooling coil and an ASHRAE 62.1 compliant double sloped drain pan. B. The direct expansion (DX)cooling coils shall be fabricated of seamless high efficiency copper tubing that is mechanically expanded into high efficiency aluminum plate fins. Coils shall be a multi-row,staggered tube design with a minimum of 3 rows. All cooling coils shall have an interlaced coil circuiting that keeps the full coil face active at all load conditions. All coils shall be factory leak tested with high pressure air under water. C. The cooling coil shall have an electronic controlled expansion valve. The unit controller shall control the expansion valve to maintain liquid subcooling and the superheat of the refrigerant system. D. The refrigerant suction lines shall be fully insulated from the expansion valve to the compressors. E.The drain pan shall be stainless steel and positively sloped. The slope of the drain pan shall be in two directions and comply with ASHRAE Standard 62.1. The drain pan shall have a minimum slope of 1/8" per foot to provide positive draining.The drain pan shall extend beyond the leaving side of the coil. The drain pan shall have a threaded drain connection extending through the unit base. Job Number: WTZ8Z4 Page Prepared Date: 3/18/2019 Job Name: MFIA Woodward Elementary-TB 22 of 28 www.DaikinApplied.com Specification for RTU-1 2.08 SUPPLY FAN A. Supply fan shall be a single width,single inlet(SWSI)airfoil centrifugal fan. The fan wheel shall be Class II construction with fan blades that are continuously welded to the hub plate and end rim.The supply fan shall be a direct drive fan mounted to the motor shaft. Belts and sheaves are not acceptable due to the additonal maintenance. B. All fan assemblies shall be statically and dynamically balanced at the factory, including a final trim balance, prior to shipment. C. Supply fan and motor assembly combinations larger than 8 hp or 22"diameter shall be internally isolated on 1" deflection,spring isolators and include removable shipping tie downs. D.The fan motor shall be a totally enclosed EC motor that is speed controlled by the rooftop unit controller. The motor shall include thermal overload protection and protect the motor in the case of excessive motor temperatures. The motor shall have phase failure protection and prevent the motor from operation in the event of a loss of phase. Motors shall be premium efficiency. E.The supply fan shall be capable of airflow modulation from 30%to 100%of the scheduled designed airflow. The fan shall not operate in a state of surge at any point within the modulation range. 2.09 HEATING SECTION A. The rooftop unit shall include a natural gas heating section. The gas furnace design shall be one natural gas fired heating module factory installed downstream of the supply air fan in the heat section. The heating module shall be a tubular design with in-shot gas burners. B. The module shall be complete with furnace controller and control valve capable of 5:1 modulating operation. C. The heat exchanger tubes shall be constructed of stainless steel. D.The module shall have an induced draft fan that will maintain a negative pressure in the heat exchanger tubes for the removal of the flue gases. E. Each burner module shall have two flame roll-out safety protection switches and a high temperature limit switch that will shut the gas valve off upon detection of improper burner manifold operation. The induced draft fan shall have an airflow safety switch that will prevent the heating module from turning on in the event of no airflow in the flue chamber. F. The factory-installed DDC unit control system shall control the gas heat module. Field installed heating modules shall require a field ETL certification.The manufacturer's rooftop unit ETL certification shall cover the complete unit including the gas heating modules. 2.010 CONDENSING SECTION A. Outdoor coils shall have seamless copper tubes, mechanically bonded into aluminum plate-type fins.The fins shall have full drawn collars to completely cover the tubes. A sub-cooling coil shall be an integral part of the main outdoor air coil. Each outdoor air coil shall be factory leak tested with high-pressure air under water. B. Fan motors shall be an ECM type motor for proportional control. The unit controller shall proportionally control the speed of the condenser fan motors to maintain the head pressure of the refrigerant circuit from ambient condition of 25-120°F. Mechanical cooling shall be provided to 259 F. The motor shall include thermal overload protection and protect the motor in the case of excessive motor temperatures. The motor shall have phase failure protection and prevent the motor from operation in the event of a loss of phase. C. The condenser fan shall be low noise blade design. Fan blade design shall be a dynamic profile for low tip speed. Fan blade shall be of a composite materia D. The unit shall have scroll compressors. One of the compressors shall be an inverter compressor providing proportional control. The unit controller shall control the speed of the compressor to maintain the discharge air temperature. The inverter compressor shall have a separate oil pump and an oil separator for each compressor that routes oil back to the compressor instead of through the discharge line. Job Number: WTZ8Z4 Page Prepared Date: 3/18/2019 Job Name: MFIA Woodward Elementary-TB 23 of 28 www.DaikinApplied.com Specification for RTU-1 E. Pressure transducers shall be provided for the suction pressure and head pressure. Temperature sensor shall be provided for the suction temperature and the refrigerant discharge temperature of the compressors. All of the above devices shall be an input to the unit controller and the values be displayed at the unit controller. F. Refrigerant circuit shall have a bypass valve between the suction and discharge refrigerant lines for low head pressure compressor starting and increased compressor reliability. When there is a call for mechanical cooling the bypass valve shall open to equalizing the suction and discharge pressures. When pressures are equalized the bypass valve shall close and the compressor shall be allowed to start. G. Each circuit shall be dehydrated and factory charged with R-410A Refrigerant and oil. 2.011 ELECTRICAL A. Unit wiring shall comply with NEC requirements and with all applicable UL standards.All electrical components shall be UL recognized where applicable.All wiring and electrical components provided with the unit shall be number and color-coded and labeled according to the electrical diagram provided for easy identification.The unit shall be provided with a factory wired weatherproof control panel. Unit shall have a single point power terminal block for main power connection.A terminal board shall be provided for low voltage control wiring. Branch short circuit protection, 115-volt control circuit transformer and fuse, system switches,and a high temperature sensor shall also be provided with the unit. Each compressor and condenser fan motor shall be furnished with contactors and inherent thermal overload protection.Supply fan motors shall have contactors and external overload protection. Knockouts shall be provided in the bottom of the main control panels for field wiring entrance. B. A single non-fused disconnect switch shall be provided for disconnecting electrical power at the unit. Disconnect switches shall be mounted internally to the control panel and operated by an externally mounted handle. 2.012 CONTROLS A. Provide a complete integrated microprocessor based Direct Digital Control (DDC)system to control all unit functions including temperature control,scheduling, monitoring, unit safety protection, including compressor minimum run and minimum off times,and diagnostics. This system shall consist of all required temperature sensors, pressure sensors,controller and keypad/display operator interface.All MCBs and sensors shall be factory mounted, wired and tested. B. The stand-alone DDC controllers shall not be dependent on communications with any on-site or remote PC or master control panel for proper unit operation.The microprocessor shall maintain existing set points and operate stand alone if the unit loses either direct connect or network communications. The microprocessor memory shall be protected from voltage fluctuations as well as any extended power failures.All factory and user set schedules and control points shall be maintained in nonvolatile memory. No settings shall be lost,even during extended power shutdowns. C. The DDC control system shall permit starting and stopping of the unit locally or remotely.The control system shall be capable of providing a remote alarm indication.The unit control system shall provide for outside air damper actuation, emergency shutdown,remote heat enable/disable,remote cool enable/disable, heat indication,cool indication,and fan operation. D. All digital inputs and outputs shall be protected against damage from transients or incorrect voltages.All field wiring shall be terminated at a separate,clearly marked terminal strip. E.The DDC controller shall have a built-in time schedule.The schedule shall be programmable from the unit keypad interface.The schedule shall be maintained in nonvolatile memory to insure that it is not lost during a power failure. There shall be one start/stop per day and a separate holiday schedule.The controller shall accept up to sixteen holidays each with up to a 5-day duration. Each unit shall also have the ability to accept a time schedule via BAS network communications. F. The keypad interface shall allow convenient navigation and access to all control functions. The unit keypad/display character format shall be 4 lines x 20 characters.All control settings shall be password protected against unauthorized changes. For ease of service,the display format shall be English language readout.Coded Job Number: WTZ8Z4 Page Prepared Date: 3/18/2019 Job Name: MFIA Woodward Elementary-TB 24 of 28 www.DaikinApplied.com Specification for RTU-1 formats with look-up tables will not be accepted. The user interaction with the display shall provide the following information as a minimum: 1. Return air temperature. 2. Discharge air temperature. 3. Outdoor air temperature. 4. Space air temperature. 5. Outdoor enthalpy, high/low. 6. Compressor suction temperature and pressure 7. Compressor head pressure and temperature 8. Expansion valve position 9. Condenser fan speed 10. Inverter compressor speed 11. Dirty filter indication. 12. Airflow verification. 13. Cooling status. 14. Control temperature (Changeover). 15. VAV box output status. 16. Cooling status/capacity. 17. Unit status. 18. All time schedules. 19. Active alarms with time and date. 20. Previous alarms with time and date. 21. Optimal start 22. Supply fan and exhaust fan speed. 23. System operating hours. a. Fan b. Exhaust fan c. Cooling d. lnndividual compressor e. Heating f. Economizer g. Tenant override G.The user interaction with the keypad shall provide the following: 1. Controls mode a. Off manual b. Auto c. Heat/Cool d. Cool only e. Heat only f. Fan only 2. Occupancy mode a. Auto b. Occupied c. Unoccupied d.Tenant override 3. Unit operation changeover control a. Return air temperature b. Space temperature c. Network signal Job Number: WTZ8Z4 Page Prepared Date: 3/18/2019 Job Name: MFIA Woodward Elementary-TB 25 of 28 www.DaikinApplied.com Specification for RTU-1 4. Cooling and heating change-over temperature with deadband 5. Cooling discharge air temperature(DAT) 6. Supply reset options a. Return air temperature b. Outdoor air temperature c. Space temperature d. Airflow (VAV) e. Network signal f. External (0-10 vdc) g. External (0-20 mA) 7. Temperature alarm limits a. High supply air temperature b. Low supply air temperature c. High return air temperature 8. Lockout control for compressors. 9. Compressor interstage timers 10. Night setback and setup space temperature. 11. Building static pressure. 12. Economizer changeover a. Enthalpy b. Drybulb temperature 13. Currently time and date 14. Tenant override time 15. Occupied/unoccupied time schedule 16. One event schedule 17. Holiday dates and duration 18. Adjustable set points 19. Service mode a.Timers normal (all time delays normal) b. Timers fast(all time delays 20 sec) H. If the unit is to be programmed with a night setback or setup function,an optional space sensor shall be provided. Space sensors shall be available to support field selectable features.Sensor options shall include: 1. Zone sensor with tenant override switch 2. Zone sensor with tenant override switch plus heating and cooling set point adjustment. (Space Comfort Control systems only) I. To increase the efficiency of the cooling system the DDC controller shall include a discharge air temperature reset program for part load operating conditions. The discharge air temperature shall be controlled between a minimum and a maximum discharge air temperature(DAT) based on one of the following inputs: 1. Airflow 2. Outside air temperature 3. Space temperature 4. Return air temperature 5. External signal of 1-5 vdc 6. External signal of 0-20 mA 7. Network signal 2.013 ROOF CURB A. A prefabricated heavy gauge galvanized steel, mounting curb shall be provided for field assembly on the roof decking prior to unit shipment.The roof curb shall be a full perimeter type with complete perimeter support of the Job Number: WTZ8Z4 Page Prepared Date: 3/18/2019 Job Name: MFIA Woodward Elementary-TB 26 of 28 www.DaikinApplied.com . Specification for RTU-1 air handling section and condensing section.The curb shall be a minimum of 14" high and include a nominal 2"x 4" wood nailing strip.Gasket shall be provided for field mounting between the unit base and roof curb. Job Number: WTZ8Z4 Page Prepared Date: 3/18/2019 Job Name: MFIA Woodward Elementary-TB 27 of 28 www.DaikinApplied.com